Home
        LSeries Manager V1.4 Software Manual EN
         Contents
1.    ARRI    LSeries Manager V1 4 Software Manual   November 12  2013    Software Manual    LSeries Manager 1 4    Software Manual    Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 1 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    Table of Contents    1 Download and Installation                ccccccccecccseeeceeeeseeeeeeeeseeeeseeeeeeeeseeeeseeeseeeesseeseeeseeesaeeens 3  2  OVA We Lene S Manager anne 4  3 L  mphead OVerViGW sicsis ens cnate sesdsseesnavanesntSeaesendrsapesidsensentesapecedsassantesapscwsdsessantecsancusere  5  4     1   Ge     1198 Sei eee nee eee ee ee ee ee eee 6  9  Fan ModS ee ee ee eee eee 7  6 Diagnosis etter craceresctinpotoievne nrcenee tia scievncincetae EERE tn EEEE REE EEE E REEE REEERE 8  7 Firmware Update ee ee E EA E N ENE REE 9   7 1 Performing a firmware UPCate               ccccccccseccceeecceeeceueeceeeceeecsueeceeessusesueeseeessneess 9   7 2 Troubleshooting if the update process has failed               cccccccseeeeeeeeeeeeeeeeeeeeeeneees 11  8 Aduna TUN UON een een 12  9     Program Sellings ne  nsanene reiner 13  10  System CSS ACC Scns een enden 15  History    18 06 2013 Released for LSM V1 2  12 11 2013 Released for LSM V1 4    Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 2 of 15          LSeries 
2.  05 1 74 01 LEDSpot_Main hey  C  Pw Processor 1 05 00 1 05 00 LEDSpot_PIC_Pwm hey  Control Panel 2 04 00 2 05 00 LEDSpot_PIC_Disp hey    Check LY C for possible updates    Update progress           Running Pgmid  0x9081  Jump to Secondary Bootloader    done   Running Pgmid  0x9082        Programming Main program      Open file LEDSpot_Main hey  v    Transfering LEDSpot_Main hey       Cancel Update              L7 C  L1 31330CD 1489   Firmware update in progress  75   total 37            When the installation is complete the message    Update process finished successfully      should be displayed in the update progress text field     Nevertheless the firmware update process is so simple  please note the following     e Be aware of your currently installed bootloaders   If the bootloaders are lower than version 2 0 an intermediate bootloader update has  to be installed to enable the lamphead to be updated to the latest firmware  this  should occur only with firmware versions prior 1 65    The intermediate update files are included in all LSeries Manager firmware bundles  and are located in the update folder    L7_Bootloaders_V2        e The update process must not be interrupted   Lampheads with an incomplete firmware installation will not work properly     even if  it seems so at first sight  To avoid unwanted cancellation of the update process  o disable any DMX or RDM communication  especially RDM discovery   do not close the LSeries Manager   do not shut down or switch off 
3.  31330CD 1489     DMX Settings       FAN Modes  Diagnosis   amp 4 Firmware Update        LSeries Manager DMX Address  fr  y  DMX Mode    6   White  amp  RGBW 16 Bit Mode                       L7 C  L1 31330CD 1489    DMX Settings    DMX Implementation Table  V3 3 Details    DMX Signal loss behavior    1 Hold    Set DMX Settings            DMX Implementation Table  Here you will see the version of the DMX implementation table which is used by the    currently installed firmware on your lamphead  Clicking on  Details  will open the  appropriate PDF document where you can find detailed information about the DMX modes  provided by the lamphead     DMX Address   Here you can choose the DMX start address  channel or slot  of your lamphead   Depending on the selected DMX Mode the channels required for each lamphead should be  allocated  if necessary up to 16 channels right away  Do not overlap  Either several  lampheads share the same DMX address range or a lamphead uses its own  individual  DMX address range     DMX Mode  Here you can select the DMX Mode  A detailed overview of the occupation of the individual  DMX channels can be found by clicking on  Details   see  DMX Implementation Table        DMX Signal loss behavior  Here you can change the behavior of the lamphead if it loses its DMX signal     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 6 of 15          LSeries Manager V1 4 S
4. It then will be    ignored also by the automatic lamphead detection    The lamphead will be detected again after a restart of the LSeries Manager or if the  lamphead will be switched off or disconnected from USB for more than 5 seconds and then  switched back on or reconnected to USB     Refresh data   This will reread all relevant data from the lamphead and re initialize the representation of  the fixture inside LSeries Manager  This might be necessary if the user has changed some  settings directly via the built in Control Panel or via RDM while the lamphead is connected  to the LSeries Manager     Set Factory Defaults  This will reset some lamphead settings to factory default values     e DMX Mode  e DMX Address  e FAN Mode    e Indication LEDs    Identify  This is used to physically identify a lamphead by flashing its lights  L7 C flashes blue  all    other white   This may be helpful  if more than one lamphead is connected to LSeries  Manager and the user has to identify the correct one     Restart   This will perform a reset of the lamphead  The fixtures firmware will restart as if it has been  switched off and on again  LSeries Manager may lose the connection to the device and  remove it  then detect it again after the restart has been finished     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 12 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       
5. Manager V1 4 Software Manual   November 12  2013       Software Manual    1 Download and Installation    This software has been tested on the following operating systems     Microsoft Windows XP  32 bit   Microsoft Windows 7  32 bit   64 bit   Microsoft Windows 8  32 bit     In general LSeries Manager should work on all Windows desktop versions up from  Windows XP  but there is no guarantee that it will work properly on not tested operating  systems        Please do not connect the lamphead via USB to the computer before the LSeries Manager  has been installed     1  Visit our LSeries download center at http   www arri com I series downloads  2  Download the latest LSeries Manager Bundle Version     Including the LSeries Manager and the newest firmware version    3  Start the installation by double clicking on the installer executable     If the download consists of a zip file  you have to extract the installer before      The installation requires administrator privileges  If your user profile does not provide  administrator privileges  Windows may ask you for an administrator account login or you  have to start the installation by right clicking on the installer file and choosing    start as  Administrator        Note    Once the installation is finished  it is recommended to connect a L7 lamphead before you  start the LSeries Manager the first time    This will finalize the USB driver installation on your system  If this is not done there can be  errors when the LSeries Ma
6. Software Manual    Reconnect   This will perform a reset of the USB connection as if the USB cable has been removed and  reconnected again  LSeries Manager will lose the connection to the device for a short time  and remove it  then detect it again     9 Program Settings              LSeries Manager  V1 4 0 75  5       x           L_Series         L7 C  L1 31330CD 1489  5 B z  E A eaan LSeries Manager   Program Settings    D FAN Modes Common  Diagnosis Jv Jump directly to new connected devices  4 de re Update JV Expand all nodes of new connected devices  E LSeries Manager    ae Program Settings Firmware Updates    System messages Folder for Firmware Update files     ICAU sers Public D ocuments LSeries Manager L _V1 74 14      IV Changing the Update Files folder in node  Firmware Update  will also change global folder setting                  V Save Update logs to folder    Ic   Users Public Documents LSeries Manager UpdateLog  EI      Always preselect not installed updates of optional components by default on  Check for possible updates                Log file folders  Default folder for Service log and Error log files      CU sers Public D ocuments LS eries Manager DiagLog  Bl    JV Save system messages log to folder     CU sers Public D ocuments LSeries Manager SysMsgLog  E    Here you can change the program settings of the LSeries Manager     Common  e Jump directly to new connected devices   If enabled  the LSeries Manager will immediately go to the tree node entry of a n
7. ad containing    an overview of the system state and further important data     Read Error Log  Clicking this button will read out the internal error messages history of the lamphead     Clear  This clears the currently shown logs     Save  By clicking the button    Save    you can save all logs as a  txt file on your PC     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 8 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    7 Firmware Update    7 1 Performing a firmware update            LSeries Manager  V1 4 0 75       5  xj       i  N  mn  E         C    l com        E  L7 C  L1 31330CD 1489        L7 C  L1 31330CD 1489    Firmware Update            DMX Settings    FAN Modes Update files folder   Diagnosis  C  Users Public Documents LSeries Manager L7_V1 74 1  Ey  4 Firmware Update    LSeries Manager Component   Current version Update version   File                C  Primary Bootloader 3 04 00 3 04 00 LEDSpot_PrBo hey  C  Secondary Bootloader 3 06 00 3 06 00 LEDSpot_SeBo hey  Main Program 1 70 05 1 74 01 LEDSpot_Main  hey  C  PwM Processor 1 05 00 1 05 00 LEDSpot_PIC_Pwm hey  Control Panel 2 04 00 2 05 00 LEDSpot_PIC_Disp  hey       Check L7 C for possible updates         Update progress        Start Update        It is quite simple to perform a firmware update     1  The LSeries Manager checks the currently installed firmware for the 
8. d  9082 LEDSpot SeBo Vers  3 6 0 1414 May 30 2012 18 35 21  LEDSpot Vers  1 70 5 1744 Feb 08 2013 16 15 17 HW Rev   3   PWM Processor Sw Ver   1 5  User Interface Sw Ver   2 4          Caldata ver  1 5  CalDate  1352904585  CalDataLoaded  1        LEDSpot   Identno  L1 31330CD  Approvalno    no    Serialno  1489   Controller   Identno  L4 31671 0  Approvalno  DL2243  Serialno  124400081  PowerSupply   Identno  L4 31871 0  Approvalno  DL2246  Serialno  123900003  FAN   Identno  L4 31711 3  Approvalno  AF1141  Serialno  122300670  LightEngine   Identno  L4 31661 R  Approvalno  CF1132  Serialno  122904675  UserInterface  Identno  L4 31761 0  Approvalno  AF1132  Serialno  121502176    ARRI DMX Protocol Version  3 2  DMXAddr  1  DMX Protocol No   2  Description    FAN Settings  FanType  ebmpapst 4412F 2GLR  HeatsinkType  120mm hybrid  FAN RPM  1050  FAN PWM  0 00   FAN level  80 00   act  FAN RPM  1073 73    Used Fan Settings from Fan Menu  user FanMode   FAN HYBRID LOW  DimmADC Level      Used Color Mode  HSI  Used Automatic Zero  Force GREEN Zero and SAT 100  ON    Used Status Indication  Status LEDS and Backlight ON  used Status Tndication  Temneratiir linit Nenree Celsius    The LSeries lampheads provide some internal logging facilities which may be helpful for  failure diagnosis  The logs are important for your ARRI service partner for a better  understanding of fixture issues     Read Sevice Log  By clicking this button a detailed service log will be read out from the lamphe
9. e with a strange serial number      5  If the lamphead will not be recognized by LSeries Manager  Close LSeries Manager  and start it again     6  If the lamphead still is not recognized by LSeries Manager then switch off the  lamphead  wait approximately 5 10 seconds and switch it on again     7  If the lamphead will be recognized by LSeries Manager   Try to start the update again     8  If this will fail again  please note again the error messages      lf the lamphead does not react or the problem still persists please contact your local ARRI  service partner  It is important to store the collected error messages and log data to provide  it to the ARRI service partner if needed     Note  Lampheads with an incomplete firmware installation will no longer work properly      even if it seems so at first sight     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 11 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    8 Additional functions    By right clicking on a lamphead entry in the LSeries Manager connected lamphead list a  popup menu will be opened providing some additional functions        DMX Set Remove L7 C  L1 31330CD 1489      FAN Mod Refresh data   Diagnosi Set Factory Defaults  E  Firmware Identify     LSeries Man Restart  Reconnect           Remove lamphead  Choosing this option will remove the lamphead from the LSeries Manager  
10. ew  connected device     e Expand all nodes of new connected devices   If enabled  all sub entries of a new connected device will be opened and be visible  by default     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 13 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    Firmware Updates  e Folder for Firmware Update files   If you have different firmware versions available  you can here change the folder  used by default for every new connected fixture     e Changing the Update Files folder in node    Firmware Update    will also change global  folder setting   It is possible to change the Update Files folder also in the Firmware Update section  of a connected fixture  see Firmware Updates   Changing the folder there will only  affect the correspondent fixture  unless this checkbox is enabled here     e Save Update logs to folder   If enabled  the content of the update progress text field will be stored automatically  to an update log file inside the selected folder  This log data might be very helpful if  you have to contact an ARRI service partner in case the update process will fail  For  this reason it is highly recommended to enable this feature     e Always preselect not installed updates of optional components by default on    Check  for possible updates      Do not enable this  unless you have been instructed by an ARRI technic
11. ian     Log file folders  e Default folder for Service log and Error log files   This is the default folder where the Service log and Error log files will be stored if  you choose    Save    in the Section    Diagnosis        e Save system messages log to folder   If enabled  the LSeries Manager will store the System Messages automatically to a  log file in the selected folder  Each time the program is started a new file will be  created   These log messages may be helpful for failure diagnosis and are important for your  ARRI service partner for a better understanding of fixture issues and or issues with  the LSeries Manager  For this reason it is highly recommended to enable this  feature     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 14 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    10 System Messages             LSeries Manager  V1 4 0 75  a    5  x     LSeGRIeS  ARRI          L7 C  L1 31330CD 1489                 LSeries Manager   System messages                              DMX Settings     FAN Modes LSeries Manager  V1 4 0 75  started on 07 11 2013      5   33  Program settings loaded    Diagnosis 15 33 24 Start System Messages file logging     Firmware Update 15 33 24 Log System Messages to C  Users Public Documents LSeries Manager SysMsgL       LSeries M r 15 33 24 DeviceMonitor  Started  wait for connections    eres Ma
12. nage 15 33 24 DeviceMonitor  L7 found  FTDI serial  ARVVBY3P       4  Program Settings 15 33 27 Connected  L7 C  L1 31330CD 1489     15 33 27 Check installed firmware versions of L7 C  L1 31330CD 1489     p mitt 15 34 23 Read Error Log of L7 C  L1 31330CD 1489      15 34 29 Read Service Log of L7 C  L1 31330CD 1489    15 37 15 Start firmware update of L7 C  L1 31330CD 1489    15 40 03 Firmware update of L7 C  L1 31330CD 1489  finished   15 40 05 L7 C  L1 31330CD 1489  data refreshed     06 Read Service Log of L7 C  L1 31330CD 1489      The tab  System Messages  provides internal messages concerning the communication of  the LSeries Manager with the connected lampheads as well as further information and error  messages     These log messages may be helpful for failure diagnosis and are important for your ARRI  service partner for a better understanding of fixture issues and or issues with the LSeries  Manager     The LSeries manager is able to store these log messages automatically to a log file  It can  be enabled or disabled in the Program Settings     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 15 of 15    
13. nager attempts a connection to the lamphead for the first time     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 3 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    2 Start the LSeries Manager    The LSeries Manager can be started by double clicking on the created desktop short cut  or  the usual start methods              LSeries Manager  V1 4 0 75   lof x     lL ceries  ARRI      LSeries Manager       LSeries Manager    ARRI    LSeries Manager    ah                LSeries Configuration  amp  Service Tool    Version 1 4 0 Build 75  Copyright    2013   ARRI Lighting    http  www  arni  com     lt seryice lighting  arri de gt           The LSeries Manager detects lampheads connected via USB to the computer  automatically  Multiple lampheads can be connected simultaneously by utilizing additional  USB ports     Each connected lamphead will be added to the tree list on the left side of the program  window  Here you can navigate through the different program functions     Note   While the LSeries Manager application is communicating with the lamphead it is  recommended  but not mandatory  except while performing a firmware update   e not to change any settings via the onboard control panel of the lamphead  to avoid  inconsistencies   e and that no DMX or RDM communication takes place with the lamphead  which  could lead to communication e
14. necessity of  any update automatically and will then pre select the appropriate firmware modules  for update    o Only if your currently installed firmware version  main program  is lower than  1 65 you have to click on    Check L7 for possible updates    to initiate the  check manually    o Please do not change any of the pre selections unless you have been  instructed by an ARRI technician    o If your lamphead does not contain an onboard control panel  you do not  have to select it     2  The firmware update process can be initiated simply by clicking on    Start Update        The update will start and the selected firmware components will be transferred and installed  on the lamphead  The update process will take some time up to some minutes depending  on the selected items     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen    Website  www arri com service lighting Page 9 of 15       Software Manual    ARRI    LSeries Manager V1 4 Software Manual   November 12  2013            LSeries Manager  V1 4 0 75  i  IOl x      SEM  u ee O O       ji                   a L7 C  L1 31330CD 1489    Firmware Update      DMX Settings     FAN Modes Update files folder    Diagnosis C  Users Public Documents LSeries Manager L _V1 74 1  By   a  a LSeries Manager Component Current version Update version   File   C  Primary Bootloader 3 04 00 3 04 00 LEDSpot_PrBo  hey  C  Secondary Bootloader 3 06 00 3 06 00 LEDSpot_SeBo hey  Main Program 1 70
15. oftware Manual   November 12  2013       Software Manual    The DMX Settings will be applied to the lamphead by clicking the button    Set DMX  Settings        5 Fan Modes            LSeries Manager  V1 4 0 75  p  Ioj xi    l cor RAG         B  L7 C  L1 31330CD 1489      DMX Settings  D  Diagnosis   amp 4 Firmware Update      LSeries Manager       L7 C  L1 31330CD 1489    FAN Modes    FAN Mode    3   FAN HIGH    Set FAN Mode               Fan Mode  Here you can choose the different Fan Modes your lamphead provides  This feature is  available from firmware version 1 68 2     The FAN Mode will be applied to the lamphead by clicking the button    Set FAN Mode        Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 7 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    6 Diagnosis               LSeries Manager  V1 4 0 75     5  x     LSeRIes  ARRI         L7 C  L1 31330CD 1489     Fe L7 C  L1 31330CD 1489    Diagnosis    D rA Read Service Log   Read Error Log   Clear   Save       4 Firmware Update  LSeries Manager                                      __ mem em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em em ee em em em em em em ewe ee ee   a       PrBo  PgmId  9081 LEDSpot PrBo Vers  3 4 0 1414 May 30 2012 18 35 59  SeBo  PgmI
16. rrors in rare cases   at the same time     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 4 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    3 Lamphead Overview           LSeries Manager  V1 4 0 75     Lsencs     OR   L7 C  L1 31330CD 1489        L7 C  L1 31330CD 1489           DMX Settings     FAN Modes  Diagnosis Type  L7 C   4 Firmware Update  LSeries Manager SeialNunbe  _L1 31330CD 1489  Manufacturer  ARRI Lighting    Controller Serial Number   Control Panel Serial Number   Power Supply Serial Number    LedEngine Serial Number   Fan Serial Number     Hardware Version     Firmware Yersion     Calibration Date     L4 31671 0 DL2243 124400031  L4 31761 0 4F1132 121502176  L4 31871 0 DL2246 123900003  L4 31661 R CF1132 122904675  L4 31711 3 4F1141 122300670    3  1 72 01  PBL  3 04 00  SeBL  3 06 00     14 11 2012 14 49 45       In this view you can find an overview of some relevant information about your L7 lamphead   fixture type   serial numbers   hardware and firmware versions  calibration date     Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting    Page 5 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    4 DMX Settings       LSeries Manager  V1 4 0 75     Ioj x     Lseries  ARRI       E  L7 C  L1
17. the computer   do not switch off the lamphead   do not disconnect the USB cable     O O O O    Arnold  amp  Richter Cine Technik GmbH  amp  Co  Betriebs KG  Pulverm  hle  83071 Stephanskirchen  Website  www arri com service lighting Page 10 of 15          LSeries Manager V1 4 Software Manual   November 12  2013       Software Manual    7 2 Troubleshooting if the update process has failed    The update process of the LSeries Manager is quite robust  nevertheless there is always a  little chance for failure     First of all  Don   t panic  Mostly it is possible to repeat the update   Here you find a step by step tutorial what to do after an update has failed     Please try to do the following     1  Do NOT switch off the lamphead   Please note the error messages  The content of the update progress text field will  be stored automatically to an update log file if you have enabled this feature in the  Program Settings  This data might be very helpful if you have to contact an ARRI  service partner in case the next steps will be without success  In addition the system  messages log will also be helpful     2  Try to start the update again     3  If this will fail again  do NOT switch off the lamphead   Please note again the error messages     4  Disconnect the USB cable  wait approximately 5 seconds  lamphead should now be  removed from the LSeries Manager window  and then reconnect the USB cable   The lamphead should now be recognized by LSeries Manager after a few seconds   mayb
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  La PNL mode d`emploi - lire le livre en ligne ou télécharger  Manual consulta expedientes digitales (usuarios externos  Samsung 512N Computer Monitor User Manual  Avaya 15-601067 User's Manual  加賀片山津温泉 街湯 - 高松機械工業株式会社  Marantz DV6200 DVD Player User Manual  c. MyClass User Guide  Cisco Systems 7970G Cordless Telephone User Manual    Copyright © All rights reserved. 