Home
        5000V Graphical Megohmmeter Model 5070
         Contents
1.   Communication Port  RS 232    PC Software Report Generation  Yes  DataView      Lite  included     PC Operation of Megohmmeter  Yes    SAFETY  Safety Rating  EN 61010 1  1000V Cat  III    Double Insulation  Yes    CE Mark  Yes     1 DAR times are programmable in the Model 5070     2 Inhibit voltage is selectable at 3  10 or 20  of test voltage            Construction    ORDERING INFORMATION  CATALOG NO     Megohmmeter Model 5070  Digital  with Graphical Display  Backlight  Alarm  Timer  500V  1000V  2500V  5000V   Auto DAR PI DD  RS 232 w DataView      Lite Software   Cat   2130 30    Includes soft accessory bag  one red  one blue and one black lead with integral 5000V rated hippo clips  one jumper  lead for use with guard terminal  one 5 ft RS 232 DB9 DB25 F F to DB9 DB25 F F Cable for PC  rechargeable  battery pack  DataView      Lite software  US 120V power cord and user manual    Accessories  Optional   Cable  PC RS 232  DB9 F F 6 ft  for serial printer                                                                                                      Cat   2119 46  Leads  set of three  5 ft color coded     rated at 1000V max                                                                                         Cat   2119 55   one red  one blue and one black lead  one red  one blue and one black alligator clip   Leads  set of three  10 ft color coded rated at 5000Vmax                                                                                          Cat   2119 7
2. 6   one red  one blue and one black lead  one red  one blue and one black alligator clip   one black test probe  one red test probe   Leads  set of three  25 ft color coded rated at 5000Vmax                                                                                          Cat   2119 86   one red  one blue and one black lead with integral 5000V rated hippo clips   Leads  set of three  45 ft color coded rated at 5000Vmax                                                                                          Cat   2119 87   one red  one blue and one black lead with integral 5000V rated hippo clips     Input terminal        Backlit 320 x 240  graphical display    AC power input    Fuse holder    Input terminal  G     Input terminal          Rotary  selection  switch    RS 232 serial  interface port    Start Stop  button    Eight function  buttons    
3. The Model 5070  the latest design in  5000V Megohmmeters  is the most  innovative product in its class on the  market today  The features and  functions incorporated in this product  are the results of many years of  analyzing how megohmmeters are  used in everyday applications  The  most advanced technology available  has been applied to automate and  facilitate the testing process for these  applications     Many features incorporated in the  Model 5070  not found in any other  megohmmeter on the market today   include automatic calculation and  presentation of the Dielectric  Absorption Ratio  DAR   Polarization  Index  PI  and Dielectric Discharge   DD   The PI ratio times are also user  defined  This new advanced  megohmmeter displays the test  voltage  insulation resistance and the  leakage current during and after the    5000V Graphical Megohmmeter  Model 5070    test  Capacitance of the sample and  discharge voltage present at the test  leads is displayed at the conclusion of  the test  The Model 5070 is the only  megohmmeter to offer both a graphical  plot of the test right on the instrument   as well as a digital presentation of the  test results  The Model 5070 also  offers the ability to program up to three  step voltage profiles  each containing  up to five steps     The Model 5070 is designed with the  highest level of safety features built in   The unit is packaged in a rugged  insulated case  The Model 5070  incorporates test inhibit capabilities  which will n
4. ce measurement graphically displayed    at the completion of the test at the push of a button    Move the vertical cursor to see Resistance  Output    Voltage and Elapsed Time values at the cursor position    Display of test results at the conclusion of the test    Typical display in Setup mode showing some of the    parameters that are user programmable    Typical setup screen for the Step Voltage function    Step Voltage start screen shows start and ending test voltage     test run time and some of the parameters to be monitored    Typical screen showing data recalled from stored memory   each test stored can be reviewed on screen both graphically    and alphanumerically     Specifications    MODEL  5070    ELECTRICAL  INSULATION TESTS  Test Voltage Range  500V  30k to 2000G  2T     1000V  100k to 4000G  4T     2500V  100k to 10 000G  10T     5000V  300k to 10 000G  10T     User Selectable Test Voltage  Programmable     40 to 1000V  10V increments     1000 to 5100V  100V increments  Three test voltages can be stored     Short Circuit Current   lt 1 6mA    5     Accuracy  1k to 40G    5  of Reading    3cts    40G to 10T    15  of Reading    10cts    DAR  1 min 30 sec  1   0 02 to 50 00    PI  10 min 1 min  amp  user programmable   0 02 to 50 00    DD  Current after 1 min   0 02 to 50 00  test voltage x capacitance    Capacitance Check  0 005 to 49 99  F  Max resolution 1nF    Leakage Current Measurement  0 00nA to 3mA    Max resolution 1pA    Programmable Run Time R t   1 mi
5. n to 49 hrs 59 min    Smooth Function  user selectable   Digital filtering stabilizesdisplay readings    Automatic Step Voltage  3 profiles  each containing 5 steps programmable from 40 to 5100V     Dwell time programmable from 1 min to 10 hrs per step     Maximum total time for 5 steps is 59 hrs 59 min    Temperature Correction  Operator programmable reference temperature and device under    test temperature with automatic temperature correction of resistance    Discharge After Test  Automatic    Discharge Voltage Display  Yes    Voltage Test Safety Check  0 to 1000VAC DC  16 to 420HZ   1V Resolution    Voltage Warning Indicator  Yes  gt 25V    Test Inhibition 2   Yes  gt 25V    Guard Terminal  Yes     adjustable from 25 to 1000V    depending on test voltage range in use    DISPLAY  Backlight  Blue  Electroluminescent    Display Size  3 75 x 3   93 x 75mm     Display  Graphical  320 x 240 resolution    Power Source  Eight NiMH rechargeable batteries  Line power  85 to 256VAC  50 60Hz     GENERAL  Dimensions  10 63 x 9 84 x 7 09   270 x 250 x 180mm     Weight  9 5 lbs  4 3kg     Protection Index  IP53    OTHER SPECIFICATIONS  Report Print Out Direct to Printer  Yes     preset format    Storage of Readings over Time R t   128kB memory    Programmable Reading Intervals  5 sec to 15 min    Test Voltage Display  Yes    Elapsed Test Time Display  Yes    Real Time Date Display  Yes    Test Voltage Lock out  User programmed    Storage of Test Results  Stores over 1500 test results  
6. ot allow test voltages  to be generated if a live sample is  detected  The test terminals are  recessed to ensure operating safety   The test leads  rated for 5000V for both  testing and measurement  are the only  truly safety approved 5000V leads on  the market today  The Model 5070 can    be operated from an internal  rechargeable battery system or from  AC line power     The Model 5070 offers additional  functionality in that an RS 232 port  provides the ability to configure the  units from a PC and run the test from  the PC  Automatic documentation of  test conditions and test results  eliminates the need for writing down  information  Test reports can be  generated directly from the instrument  to a printer or through the PC using the  DataView       graphing and analysis    software provided     The list of features  functions and  benefits goes on and on  If you are  looking for a truly advanced 5000V  Megohmmeter  the AEMC Model 5070  is the best in class and available at an  affordable price     Features        True Megohmmeter              Test voltage combinations of 500V  1000V  2500V and 5000V        Insulation measurements from 30k to 10 000G  10T         Selectable and programmable test voltage  40 to 5100V         three can be stored        Automatic step voltage with programmable step and dwell times        three profiles can be stored  each with up to five steps        Programmable temperature compensation of resistance readings        Large graphic display 
7. rements  The Model 5070 also allows for  storage of three different voltage selections     Test Voltage Lock out     Gives the flexibility  to limit the maximum output test voltage to  any value from 40 to 5100V to protect delicate  equipment from accidental exposure to  excessive test voltages     Timer Function     Program a test run time  from one minute to 50 hours     Record Function     provides the option to  automatically store the data from a timed test  at programmable intervals or to store the  results of the test manually at the push of  a button at the end of the test     Print Function     Provides a direct print  out to a printer of test results in a predefined  format     Graph Function     Provides a graphic  representation of a time test on the display of  the Model 5070 of insulation resistance vs  time   If the step voltage mode is selected  the step volt   age is also shown graphically     Ramp Function     Allows programming of three  different ramp test profiles  each containing up to  five voltage steps between 40 and 5100V and  time per step of up to 10 hours     Temperature Function     Provides the ability to  display insulation resistance temperature cor   rected to a specific reference temperature     Model 5070 checking insulation resistance on feed cables to  a three phase motor     Functional Displays    Alphanumeric and analog bargraph displays of Insulation    Resistance  Leakage Current and Test Voltage during the test    Insulation Resistan
8. ting     Dielectric Discharge         Test old or water damaged    installations over long time runs        Motor insulation resistance    measurements        Computer controlled production    line testing        Predictive maintenance by storing    results in PC for trend analysis        User selectable voltage testing to    provide application specific testing    Model 5070 performing insulation test on a generator     Insulation can be subject to slow  gradual  degradation over long periods of time  as well  as sudden damage  The effects of moisture   dirt  corrosion  chemical penetration and even  vibration can cause degradation of insulation   The effects of this degradation can easily be  documented by using the automatic  Polarization Index test feature standard on all  models  Comparing the results over time will  provide valuable information for preventative  maintenance measures     Key Functions    Smooth Function     This function is very  useful when the readings on the display are  unstable and hard to read  It applies a digital  filter to the displayed readings to smooth out  the presentation  It does not effect the  measurement or recording of data     Alarm Function     Allows for the setting of a  low limit resistance value for each test voltage   below which a buzzer will sound alerting you to  a problem condition     Selectable Voltage     Provides the flexibility  to program an exact voltage for a specific test  to any voltage from 40 to 5100V in 10V  inc
9. with five line alphanumeric display and graph    of all test results        Automatic calculation of DAR  PI and DD ratios        Direct measurement and display of Capacitance and Leakage Current        Display resistance  test voltage and run time        Programmable test run times and PI ratio times        Smooth and Alarm functions        Automatic test inhibition if live sample   gt 25V         Automatic discharge and display of discharge voltage        Graphic and digital display of test voltage  resistance and more        Bright blue electroluminescent backlight        Programmable test voltage lock out        Programmable alarm setting        Auto power down when not in use        AC or DC powered with rechargeable NiMH batteries        RS 232 interface for direct printing of results  serial or parallel output         128kB memory for storing extensive field test data        Configure instrument and run tests from a PC        Includes DataView      Lite software for data storage  analysis and    report generation        Rugged  weatherproof field case        Designed and built to IEC safety standards        EN 61010 1  1000V Cat  III    Applications        Test insulation on cables     transformers  motors  generators   insulators and wiring installations        High resistance or absorption tests        Spot reading tests        Timed resistance measurements        Dielectric Absorption Ratio  DAR     and Polarization Index  PI  tests        Multi layer insulation tes
    
Download Pdf Manuals
 
 
    