Home
Manual - B&B Electronics
Contents
1. Auto detect 115200 8 N 1 SCRC NOTE 1 Supplied RS 232 cable must be used Straight through or cross over will not work 2 If Console screen does not appear select Enter 10 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 1 Using a VT100 Terminal emulation program typically HyperTerminal in Windows open the computer COM port connected to the switch using supplied RS 232 cable 2 In the HyperTerminal Port Settings window set HyperTerminal configuration e Serial baud rate 115200 Data Bits 8 Parity NONE Stop bits 1 Flow Control NONE 3 If Console screen does not appear select Enter Navigating Console Mode The Console Login Screen will appear prompting the user for User Name and Password Default settings e User Name admin e Password admin D Gel 3 oe ei File Edit View Call Transfer Help User Login User Name admin Password Up key Up Down key Down Left key Left Right key Right Confirm Enter B amp B Electronics All Rights Reserved Connected 0 00 46 ANSIW 115200 8 N 1 SCROLL CAPS MN capture The Console mode screen has 4 configuration options 1 Overview 2 IP Setting
2. 16 17 C 18 19 20 21 022 023 za C 25 26 Aaa vete MAC Address To Port 02 6F 04 32 06 00 02 BF 04 32 00 00 Note 1 Defined MAC addresses assigned port can be modified 2 Improper static unicast address may cause communication problems 3 All static addresses can be found in MAC Address Table 4 Do not add reserved addresses such as GMRP address to the address table Reserved addresses are often used as managed address Manual Documentation Number ESW500series 0912m 31 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Chapter 5 Administration SNMP The simple network management protocol SNMP is used by network management systems to monitor network attached devices for conditions that warrant administrative attention The SNMP V1 V2c SNMP V1 and SNMP V2c use a community string match for authentication which means that SNMP servers access all objects with read only or read write permissions using the community string public private It consists of a set of standards for network management including an application layer protocol a database schema and a set of data objects SNMP exposes management data in the form of variables on the managed systems which
3. 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Bandwidth Bandwidth is a rate of data transfer related to channel capacity for communication Rate limiting is used to control the rate of traffic sent or received on a network interface Traffic that is less than or equal to the specified rate is sent whereas traffic that exceeds the rate is dropped or delayed Rate limiting is performed by policing discarding excess packets queuing delaying packets in transit or congestion control manipulating the protocol s congestion mechanism Policing and queuing can be applied to any network protocol Congestion control can only be applied to protocols with congestion control mechanisms such as the Transmission Control Protocol TCP Port Rate Control 1 10 11 12 13 Note Mot Limited 14 16 17 18 19 20 21 22 23 24 Not Limited ki 25 Not Limited e 26 Not Limited Not Limited Mot Limited bi Not Limited ki Mot Limited bi Not Limited ki 1 CO 10 11 12 13 NotLimited Not Limited ki Not Limited 14 15 16 17 18 19 20 21 22 23 24 25 26 1 Switch monitor all type packets and not limited decreases overall
4. PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Mounting Options Removal Din Rail Mounting Panel Mount Dimensional Drawing ESW508 Series Front Panel B BeB ELECTRONICS 138 8mm Bottow View osuoo DC 12 36V AC 10 24V 6 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com ESWG510 Series Front Panel B Bottow View 121 1mm ESW516 Front Panel Bottow View 149 1mm ho DC 12 36V AC 10 24V O O O O O O O O O O O 70 4mm O O O O O O O O O O O 70 4mm 130 8mm Front Panel B SA O O OgsB ELECTRONICS VSE mm DC AC Power Connections ESW508 ESW516 Series ESW510 Series rs NC NC DC 12 36V AC 10 24V DS TE me Fault Relay Relay Normally Open Gigabit Combo Ports Default Settings Console Port DB9 Male Serial baud rate 115200 Data Bits 8 Parity NONE Stop bits 1 Flow Control NONE Serial Cable Pin out PC Serial Console Port Port DB 9 DB9 Lco
5. 13 Welten 13 Chapter 3 Web Browser Configuration 14 WEB SERVER ACCESS idiotas 14 BASIC ed e 15 SYSTEM INFORMATION uuu u suu di re Leta EE EE 15 PASSWORDS Re 15 ACCESABLE IP 15 PORT EE 16 TES A liada 16 A RL EE 17 Chapter 4 Advanced Settings 18 RINGO jun nun u RI A ON A NE un uns nunus 18 SinOle RINGON CONTIGUI QUOM aiii iii oie 18 Dual RingOn Configuration nn nn cnn nn 19 Status and Port State definitiOn nano 19 RAPID SPANNING TREE PROTOCOL RSTP kk 20 RS TR SOU DoS 20 RSET IN OM ALO s erii eto ue Lax ee Ni ehe andes nibus ust LEE ELE pP P LES nd 20 PROFE GOBTIQUI aco i iu uma DAA A kaba akata eee eee eee RPM IQ PE 21 MEAN VIRTUAL LAIN a as dai NS Rua A AAA AA UE ar ORE Rn t bu SA Pri RR 22 POPU VLAN SeOEPDD iy e M M 22 O02 LAO VEAN SE Dee DID LoS de ni 22 pudet Tc AA A AA AAA A A A ee 24 OOS OUALTTY OF SERVICE aa a ee aa 24 OOS SGE IPD LL ML AL ee ey ey eT ee eS ee eee ee ee ee Pee ey Pee eee DE 24 Port PIIOH II m pie Ne A EE 25 IGMP SNOOPING INTERNET GROUP MANAGEMENT PROTOCOL aaa 27 DROADCAST STORM PROTECTION WER 28 PANDWIDIP tatiana rotar aer 29 PORAMI POP uu u ua iy a ear 30 STATIC MAC ADDRESS FORWARDING CONFIGURATION ccseeceueeveusuveuseueuveuteveutaveuteueuteuseteutaveutaueutenns 30 Table Congr Tnm 30 Chapter 5 Administration 32 SIM Pas IE CDM C nM Ad yaqa nkuna UM C
6. 5 packets received 0 packet loss round trip min avg max 0 5 0 5 0 6 ms The default settings are Setting Description Default value Target IP IP address of device blank Size Size of test ping packet 60 Number The number of packet which will be 1 sent Interval The interval time between transmitted 1000 ping packets Timeout The no response timeout 5000 Note 1 DNS is not support Manual Documentation Number ESW500series 0912m 33 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Email Warning The Email Warning function allows e mail alerts to be sent to defined users when port link Up or Down changes state Relay Warning is enabled Broadcast Storm events take place and every 12 hours The 12 hour report displays a log file of switch activities Email Warning Email Alerts Enable Disable Recipient Email Address Setting Description Default value Email Alerts IP address which is desired for you disable SMTP Server The name or IP SMTP Server blank SMTP User Account User Name of SMTP Server blank SMTP Password Account password for this user name blank Recipient Recipient address blank Return Email Address blank Once the settings are configured correctly and Save is select
7. 8 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Network Settings e P address 192 168 118 100 e Subnet Mask 255 255 255 0 e Gateway 192 168 118 1 Default Security e User Name admin e Password admin VLAN e All Ports are members of VLAN 1 management VLAN Ethernet Port Configurations RJ45 Copper Ports e Half Duplex e Full Duplex e Auto Negotiation 100Base Fiber Ports e Full Duplex 1000Base Copper Fiber Ports e Full Duplex Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Chapter 2 Initial Setup Configuration The following information will explain how to access the unit for the first time There are three ways to configure the IP address setting console mode telnet and a web browser Telnet Mode Before the Managed switch is installed the Telnet Mode feature can be used to enter network settings To open a telnet session select the Start button then either o
8. Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Factory Default The Factory Default page allows the managed switch to be set back to default settings This will include the user name password and network settings z B amp B Electronics HyperTerminal E zlaj x File Edit View Cal Transfer Help 1 Overview 2 IP Settings SM Factory Default A Logout n n n n n n n n n n n n n n n n n n Are you sure to do factory default a r e j n n n n n n n n n n n n n n n n n n a Up key Up Down key Down Left key Left Right key Right Confirm Enter B amp B Electronics All Rights Reserved Connected 0 07 51 ANSIW 1152008 1 SCROLL CAPS MN Logout When finished with viewing and configuring the settings in Console Mode arrow down to the Logout page and select Yes B amp B Electronics HyperTerminal D x File Edit View Call Transfer Help 1 Overview 2 IP Settings 3 Factory Default DERE DD De De DD De De De DD De De 2 Are you sure to logout 3 a ES J Up key Up Down key Down Left key Left Right key Right Confirm Enter B amp B Electronics All Rights Reserved 115200 8 N 1 Manual Documentation Number ESW500series 0912m B8B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 4
9. The recovery time in the event of a break is less than 15 ms Two types of RingOn configurations are available single loop and dual loop Dual loop configurations connect two or more single loops When configuring dual rings unique 1D s are used for each ring Single RingOn configuration mm Ej VIA Rin DAAT T F si MT MIT Single Ring The web configuration screen shot illustrates the steps needed to implement a single ring In this case the switch is automatically configured as Master Port 1 used for communications and Port 2 blocked Only the master will display a Port Status of Blocked port Redundancy Settings Redundancy Setting Ringon v H RingOn Port UK D Completed Port 1 Fwd Port 2 Block p RingOn Not Applied Port 3 Fwd Port 4 Fwd B RingOn Not Applied Port 25 Fwd Port 26 Fwd la Couple Not Applied Port 1 Fwd 18 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Dual RingOn Configuration Two types of RingOn configurations are available single loop and dual loop Dual loop configurations connect two or more single loops When configuring dual rings unique
10. an a Lo0BaseT X 100Base IEEEB02 3ab 1000Base X TI IEEE802 3z 1000BaseSX LX LHX ZX IEEE802 3x Flowconro J Packetbuffer 256kbytes IT Processing Type Store and Forward FCC Part 15 CISPR EN55022 Generic Standard for Light Industrial Per EN61000 6 1 Environments EMC Level 3 EN61000 4 2 ESD Contact 6kv 8kv EMC Level 2 ENG1000 4 4 EFT Signal ports 0 kV DE Power ports 4 1kv AC Powerports LIN o Earth ground ports3 NA EMC Level 2 EN61000 4 5 Surge Signal ports O5V D C Power ports LIN A C Powerports LIN EMC Level 3 EN61000 4 6 CS Y Signal ports 10Vrms D C Power ports 10Vrms AC Power ports 10Vrms Earth ground ports3 NA IEC 60068 2 27 poo Manual Documentation Number ESW500series 0912m B8B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com
11. describe the system configuration These variables can then be gueried and sometimes set by managing applications Over TCP IP SNMP usually uses UDP ports 161 SNMP and 162 SNMP traps SNMP agents reside in network devices where they use MIBs information specific to the device to interface the devices with the NMS which then monitors and controls devices via these agents An SNMP Trap is a message that is transmitted when a trap event occurs A valid trap receiver will receive a trap message upon a trap event occurring e RFC1213 MIB supported e Cold start trap supported Diagnostics Scan Network and Ping are two diagnostic tools are provided with your unit Scan Network will provide a list of active network devices The Ping function uses the ping command to give users a simple but powerful tool for troubleshooting network problems Scan Network Scan Network will display IP address MAC address and its current status active or Inactive Scan Network Scan Network Network Client List IP Address MAC Address Status 10 1 0 1 00 06 B1 0E AD BO Active 2 10 1 0 2 00 0F 1F 66 47 BE Active 3 10 1 0 4 00 0F 1F 66 34 92 Active 4 10 1 0 5 DO 0F 1F FA B4 F5 Active 5 10 1 0 6 00 14 22 0B F1 54 Active 6 10 1 0 9 00 02 B3 08 38 16 Active H 10 1 0 11 00 80 4D 0D 01 DE Active 8 10 1 0 14 00 E0 18 28 EA B4 Active 9 10 1 0 18 00 10 83 98 C2 80 Active 10 10 1 0 19 00 18 4D 2D E8 23 Active 32 Manual Documentation Number ESW500s
12. latency 2 Switch will drop packets at limited rate when flow control is disabled B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Manual Documentation Number ESW500series 0912m Mot Limited bi J Mot Limited ki Mot Limited Not Limited ki J 29 Port Mirroring Port mirroring is used on a network switches to monitor the network traffic of a specific port The selected port s Ethernet traffic is duplicated and sent out a 2 specified port This is commonly used with network monitoring hardware or software Port Mirroring Port Mirroring Enable C Disable From Port ZI 7 LAT GT eil 18 of 20 ail aal 23 24 25 26 I MEUM 3 GO a GG 5 EMEN C 7 CO n GO 9 G 10 NNNM 12 ERU 14 1501 16 17 C 18 G 19 20 O 21 C 22 23 O 24 O 25 C 26 s Al C Ingress Data Capture e Egress Data Capture From Port This is the source port data that is to be copied and monitored To Port This is the destination port data is received from source port and analyzed Data Each port being monitored will transmit and receive data During port mirroring the ingress data egress data or both can be mirrored to the selected port Note 1 Port mirroring will disable IGMP s
13. overview of page function is available B B amp B ELECTRONICS Home gt Overview Service Overview Basic Info Notes Managed Switch K The Overview page display Description Contact Info MAC Address Firmware Version Current Time me The settings are configurable on the followir V1 00 03 screens 2011 03 13 08 22 40 48 17 37 System Update Firmware 14 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Basic Settings System Information The System Information Page allows the user to assign a unique name location of the switch type of function and contact name which will assist in developing a network layout The information will also be available in SNMP Home gt Basic Settings gt System Info Basic Settings System Info Settings Switch Location Overview APA Switch Description Managed Switch System Info Password Contact Info Accessible IP Port 1P Each setting in the System Info Settings page allows a maximum length of 64 characters Password Settings The Password Settings page allows up to 3 users to assign unique Users Names and Passwords The U
14. www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 37 Backup Settings The managed switches configuration can be saved as a cfg file and stored for later use Select Download then Save At that point you will be able to select a file location Note 1 The configuration file is saved with checksum Do not edit this file Backup Settings Download Switch Settings to a Location Download Upload Saved Settings to Switch Browse Upload To restore a saved cfg file select Browse and select the correct file Next select the Upload button When the transfer is complete the switch will restart Note 1 Please use the extension file cfg and ensure the file is not altered Altered files will fail when the CRC check sum operation during uploading 2 When restore configure the power should not be shut down Factory Default The Factory Default is used to restore the shipped default configuration To restore select start then OK Factory Default Restore Factory Default Start Note 1 It is recommended to save a current cfg file before restoring default settings 38 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Comm
15. 0019 0020 0021 0022 0023 0024 0025 2011 01 19 2011 01 19 2011 01 19 2011 01 19 2011 01 19 2011 01 19 2011 01 19 2011 01 19 2011 01 19 03 45 04 03 48 15 03 48 31 05 33 37 21 48 41 21 48 42 21 48 43 22 24 56 22 34 20 Note This operation is support by Java Logging Event Table Cold start Warm start Port link up and down Power off Authentication fail Port traffic overload Login info RingOn info System Update Firmware Update To keep your managed switch up to date with the latest firmware a field upgrade procedure is login System login Link Link Link Link login login BBElectronics login web server User Passwd configure change admin login web server Port 8 link down Port 8 link up Port 8 link down Port 8 link up admin login web server admin login web server available Perform the following steps to upgrade the firmware Download the updated firmware img file and place in a folder Select Browse button select file Select Start to Upgrade button The current installed version can be found in the Overview sections 1 2 3 4 Firmware Upgrade Please Select a File to Upgrade Browse Note 1 When upgrade firmware the power should not be shut down Startto Upgrade Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104
16. 1D s are used for each ring The following diagram is the typical dual loop illustration EE Dual Ring The web configuration screen shot illustrates the steps needed to implement a dual ring Both ID 1 and 2 are enabled Ports 1 and 2 connect single rings Ports 3 and 4 connect the single rings together Both rings are connected together using ID 4 coupling port Once ports are connected and configuration saved the Status displays Complete Redundancy Settings Redundancy Setting RingOn a RingOn Fot 12 Incomplete Port 1 Fwd Port 2 Fwd M D RingOn Incomplete Port 3 Fwd Port 4 Fwd Z B RingOn Port 25 26 Mot Applied Port 25 Fwd Port 26 Fwd O fa Couple Por 25 Incomplete Port 1 Fwd Iv Status and Port State definition Status PortState Not Applied P1 Fwd P2 Fwd RingOn not enabled Complete P1 Fwd P2 Block RingOn Master Complete P1 Fwd P2 Fwd Ring Slave Incomplete P1 Fwd P2 Down P 2 RJ45 link broken P 2 not connected to P2 Down RingOn port Manual Documentation Number ESW500series 0912m 19 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Rapid Spanning Tree Protocol RSTP The Rapid Spanning Tree Protocol RSTP has evolved from the Spa
17. 2 38115 502 0 0 O e 3 0 0 0 0 4 1445 10 83 0 0 0 5 0 0 0 0 6 19547 68 69 0 0 MAC Address Table MAC Media Access Control address is a hardware address network adapters NICs are giving by the manufacturer The managed switch provides an 8K MAC addresses table with automatic learning and aging The MAC address table displays this table in an administrator viewable manner In the address table the MAC addresses can be sorted by specified type The address list has three sort options Auto Port and by MAC Address The MAC addresses and the ports to which they are associated with will also be displayed The STATIC status indicates the entry is controlled by the management CPU and automatic learning Manual Documentation Number ESW500series 0912m 35 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com and aging of the entry will not take place In this address table you will find multicast address if you use static multicast forwarding table or IGMP Snooping Mac Address List To Sort gt Mac Addr Refresh Auto LOI Mac Addr Gw 00 00 1C D4 E2 D7 J Unicast Valid 002 00 00 1C D4 E 1F 2 Unicast Valid 003 00 02 B3 08 38 16 2 Unicast Valid 004 00 04 0D FF 7A 90 2 Unicast
18. 33 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com 13 Chapter 3 Web Browser Configuration The Web Server provides a convenient way to configure the managed switch from web browser software such as Internet Explorer To use the web server management and monitoring functions from a host PC connected to the same LAN they must be configured with the appropriate network settings Web Server Access Two web servers types are supported HTTP and HTTPS Open the web browser and enter the IP address of the managed switch MS Internet Explorer and Firefox supported Overview Microsoft Internet Explorer provided by B amp B Electronics Ge ele nt 19 168 118 100 dn Fle Edt View Favorites Tools Help The security login window will open requesting login user name and pass word Default e User Name admin e Password admin Windows Security x The server 10 1 0 178 at Managed Switch requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection Le Remember my credentials The home page will now open displaying the Overview page The left column will display a list of configurable options At the top right the Help button is available to assist in configuration At the right an
19. 350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN2 TAG UNTAG UNTAG VLAN1 va 9 E e D VLAN Settings VLAN Port VLAN 8 802 1q VLAN Port Settings if 2 fi 3fi 4 fi 5 fi ef 7 8 1 sf oh uh ch ish 14 1 ish eh 17 1 eh 1 i 20 1 2zi 22 1 231 24 1 2s i 26 1 2 Uma v 3 unta gt 4 unta v 5 unta x 5 una x 7 uma z 8 9 Unta Tag Filter 10 Unta 11 Uma v 12 Unta 13 unta v 2 Ua 15 unta z 16 Unta 17 unta z 18 unta 19 Unta v 20 unta 7 21 unta sl 22 Ua sl 23 unta 24 unta v 25 unta 26 Unta 1 Unta TM Lee Glo 4 tele tele ella ER 802 1q VLAN Settings r i TR vk oF a 4M sf ee 7 sw oy 1 1 10 M uk 12 41 uk 14M 15 M 16 M 17M 18 M v 19 v 20 v 21 M 22 23 M 24 V 25 vw 26 v E EN EN EN ENT NE ET IM MM 2 1 0 ri roi aal rel asi 16 137 asi 1 19 20 21 22 aal 24 25 26 Manual Documentation Number ESW500series 0912m 23 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Trunking Trunking sometimes called Link aggregation is a method
20. 8 v 9 M 10 v 11 v 12 v 13 v Multicast Port Maps 14 M 15 M 16 M 17 M is v 19 M 20 M 21 v 22 v 23 M 24 M 25 v 26 v Ouery Interval Query interval time 125 5000 seconds between IGMP Query transmitions Multicast Age Time The length of the MAC address will remain in the multicast table The switch will delete this group and send leave message Broadcast Storm Protection Broadcast storm protection prevents network problems due to accidental network redundant loops reproducing broadcasts and multicasts Without this type of control the packets are received by all switches on the network and transmitted out all ports Broadcast Storm Protection Broadcast Storm Limit Enable Disable Max Bit Rate ae Limited Type Broadcast Packets Multicast Packets Destination Lookup Fail Max Bit Rate is the bit rate setting which can be adjusted between 65K bps and 90M bps or set to no limit The storm protection feature will also allow the administrator to select the types of packets that are controlled Destination Lookup Failure is also called DLF Message which means a packet type table does not match the MAC address table and the message does not belong to broadcast or multi broadcast message The way the switch handles such DLF message is just the same as it handles the acceptance of broadcast messages 28 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc
21. Cal 19 v 20 e ik 22 e 23 w 24 v ask 26 E EN E END EE MA EN E MM 2 iof rtl 32 13 14 15 16 17l 18 C EM 9 EN EN EN EM EN ai i1 2 3 A TI 5T 6 L 7TI8 9 10 i O O aa O 14 T 15 T 1 16 Ol 17 18 ol 200 21f af aal 24f al 260 LA 802 1Q VLAN Setup B amp B Electronics Managed switches also support IEEE 802 1q VLAN Implemented 802 1g VLANs can extend over multiple switches Switches can be from different manufactures as long as they support 802 1q A typical 802 1Q VLAN network and the web server configuration page can be found below Keep in mind while looking at the diagram the difference between VLAN ID frames that are tagged and PVID frame that are untagged The configuration page displays the default PVID value for 802 1Q VLAN Each port can be configured to filer remove the 802 1Q tag or pass the 802 1Q tag to the connected device Tag Filter Setting e Untagged 802 1Q tag removed e Tagged 802 10 tag passed on If the tag is not present an 802 10 tag will be added The illustration below shows an example of when the Tag Filter is configured for both untagged and tagged port settings Most PC s would be connected to a switch port that was configured for Untag The two ports connecting the switches together are uplink ports and should be setup as Tag ports 22 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61
22. Header DSCP in both IPv4 and IPv6 will be supported If DSCP priority is enabled the switch classifies traffic based on the DSCP value DiffServ is a Layer 3 marking scheme that uses the DiffServ Code Point DSCP field in the IP header to store the packet priority information DSCP is an advanced intelligent method of traffic marking as you can choose how your network prioritizes different types of traffic DSCP uses 64 values that map to user defined service levels allowing you to establish more control over network traffic Choose Enable to start priority features based on DiffServ Then select the DSCP Priority Settings button Port Priority Enable Disable 802 1p Priority 8 Enable C Disable 802 1p Priority Settings DiffServ Priority Enable C Disable DSCP Priority Settings MATAS OS C Enable 9 Disable Port Index Port Priority 802 1p Priority DiffServ Priority Enabled 7 2 x Iv 3 pr DSCP Priority Settings Differentiated Services Code Point An advantage of DiffServ allows the administrator to configure how selected applications and types of traffic are handled by assigning various grades of network service to them DSCP uses the IP header of a packet and therefore priority is preserved across the Internet DSCP is backward compatible with IPV4 TOS which allows operation with existing devices that use a layer 3 TOS enabled prioritization scheme Once DiffServ Priority is selected open the DSCP Prio
23. IMA MAE 32 DIAGNOSTICS iii EM 32 SCAN NETWORK tango obe EELER 32 PINES u m AAA ASA re AAA AA AE AA nena nee 33 EMAIL WARNING IA RAS AA AAN AA AAA RA AAA 34 Rey WO O vo bie a ES AAA ATA AAA 34 PERFORMANCE MONITOR errar ri a ai id 35 MAC ADDRESS TABLE lt a AA ARA AAA AER AR TAS 35 LOG INFOR AO NAAA TAIANA A 36 SIS TETU PDA MES di A ai ici 37 FIENWare UDI DIS AAA 37 BACKUP Setting AAA AAA AAA 38 EE EE EE 39 SPECIFICATION EE 39 Chapter 1 Introduction Overview B amp B Electronics Elinx family of Managed Industrial Din Rail mount Ethernet switches have been designed to meet light Industrial and commercial communication requirements The ESW500 Managed Series offers a variety of Industrial models The switch configurations range from 8 ports to 16 ports with all RJ45 copper to RJ45 copper with multi mode single mode and or SFP gigabit ports Two ports can be used for network redundancy by implementing our RingOn technology RingOn has been developed to provide a rapid recovery system for Industrial networks If any part of the ring disconnects network communications will automatically be restored by RingOn technology All RJ45 copper ports support auto negotiation 10 100Mbps or 10 100 1000Mbps data rate full half duplex flow control and auto MDI MDIX The Elinx switches provide advanced management functions such as RingOn VLAN Trunking QoS Quality of Service IGMP Snooping Port Rate Control Port Mirroring Static Mac A
24. User Manual Elinx ESW500Series Managed Din Rail Ethernet Switch e z gt o o g Ki 84900751 INe ESW500 Series Documentation Number ESW 500series 0912m B EISE ELECTRONICS International Headquarters 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 Website www bb elec com Sales e mail orders bb elec com Technical Support support bb elec com European Headquarters B amp B Electronics Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Website www bb europe com Sales e mail sales bb europe com Technical Support support bb europe com Original March 2011 2011 No part of this publication may be reproduced or transmitted in any form or by any means electronic or mechanical including photography recording or any information storage and retrieval system without written consent Information in this manual is subject to change without notice and does not represent a commitment on the part B amp B Electronics Manufacturing shall not be liable for incidental or consequential damages resulting from the furnishing performance or use of this manual All brand names used in this manual are the registered trademarks of their respective owners The use of trademarks or other designations in this publication is forreference purposes only and does not constitute an endorsement by the trademark holder This document was created using Author it Mic
25. Valid 005 00 06 5B 2F 5F 33 2 Unicast Valid 006 00 06 5B 2F 5F 60 2 Unicast Valid 007 00 06 58 2F 5F 62 2 Unicast Valid 008 00 06 5B 2F 5F 69 2 Unicast Valid 009 00 06 5B 2F 6C 97 2 Unicast Valid 010 00 06 B1 0E 4D B0 2 Unicast Valid 011 00 07 32 07 14 F5 2 Unicast Valid 012 00 07 3B E4 8C 58 2 Unicast Valid 013 00 07 AF 01 3C 75 2 Unicast Valid 014 00 07 E9 D6 36 3D S Unicast Valid 015 00 08 74 09 07 F4 2 Unicast Valid 016 00 08 9B8 6A 7B 1F Fa Unicast Valid Mac Address List 2 Unicast Valid 2 Unicast Valid 2 Unicast Valid 2 Unicast Valid 2 Unicast Valid Log Information The Log Info page will display the Index event number Date of event Time of event Type and Event description A total of 16 messages can be displayed on each page Each available page is selectable using the Page drop down menu All messages of event logs are saved to system The managed switch will save up to 4000 messages Once the saved messages exceed 4000 a first in first out method is used to add newer events 36 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Log Info Log Page Enable Disable 2 5 B Clear all log records 0017 0018
26. able latency data networks NTP uses UDP port 123 as its transport layer It is designed particularly to resist the effects of variable latency Home gt Basic Settings gt Time Basic Settings Time Settings C Use Local Time Use NTP SELLE 17 n3 AG U3 4b seve Canos Setting Description Default value Local Time NIP Time setting for switch system Local Time Time Zone a region of the Earth GMT 6 DST Daylight saving time Disable Date The format must be yyyy mm dd 2011 01 01 Time The format must be hh mm ss 00 00 00 Manual Documentation Number ESW500series 0912m 17 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Chapter 4 Advanced Settings RingOn RingOn is Rapid Rescue and Recovery System for Ethernet networks which is designed to provide a backup system path for communications RingOn uses two ports on each switch to form a ring with the switch automatically selecting an active port and a blocked port If a break occurs in the active line the RingOn recovery system will automatically switch ports enable the blocked port and continue to communications A break in the ring network will also activate the Fault Relay warning the administrator of the problem
27. ddress Forwarding Table SNMP Simple Network Management Protocol Diagnosis Email Relay fault warning and field Firmware Update Features v Light Industrial and Commercial 61000 6 1 specifications v 10 to 60 C or 40 to 75 C T models temperature rating v Supports IEEE 802 3 10Base T 802 3u 100Base TX IEEE 802 3z for 1000BaseSX LX LHX ZX v RJ 45 port supports auto MDI MDI X function v SC Single mode and Multi mode fiber connectors v Gigabit options with copper and SFP combo ports v Web Browser Management and Configuration v RingOn redundant rapid recovery system v Rapid Spanning Tree Protocol recover system v IGMP with Query mode for multimedia application v Port based VLAN 802 1 Q Tag VLAN v Relay alarm output for system events v Port mirroring for diagnostics v 256K bytes packet buffer v 8k MAC address table v 12 to 36 VDC power input All Models v 10 to 24 VAC ESW508 ESW516 Models v Din Rail and Panel Mount v 100 burn in testing v 5 year warranty Package Check List e B amp B Managed Switch e Din rail and panel mounting e Serial cable for console port e Installation Guide e CD with User s Manual Manual Documentation Number ESW500series 0912m 1 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb e
28. ed a hello email will be sent 1 Password e not allowed 2 Recipient and Return Email Address must be legal email address Relay Warning The managed switch has a relay output that can be used to signal the occurrence of one or more events when configured by the user In addition to the events listed on this page the relay can be used to indicate the loss of a link or a Broadcast Storm has occurred 34 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Relay Warning Warning State Warning Message Warninq Type Port Status Link Up gt Link Down Performance Monitor Performance monitoring is available for each port and displayed on the webpage The data is captured and will display the total number of events that have occurred since last power cycle All number will be reset to zero if you reset switch or there is a loss of power The data will refresh every 30 seconds Port Packets Monitor RxPkts Statistics port unicast muticest Broadcast Eror teg Pause 0 O 1 0 0 B 2 44541 240407 224392 0 3 0 4 1366 2109 1374 0 5 0 0 0 0 0 0 22932 16198 11214 0 TxPkts Statistics 564
29. ee Root Bridge information Hello Time Forward Delay Time Root Bridge Information Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com e Port Information Port Information 1 2 na um Port Information Port Configuration e Priority 0 240 A method of prioritizing how ports are blocked The value is configured in multiples of 16 with the highest value being blocked e Port Cost 1 200 000 000 RSTP method of ensuring that optimal paths will be selected after a link failure The paths are between a transmitting bridge to a receiving bridge e Admin P2P Some rapid state transactions used within RSTP are dependent upon whether the port concerned can only be connected to exactly one point to point bridge or can be connected to two or more bridges This function allows the P2P status of the link to be manipulated administratively o P2P True Enabled o P2P False Disabled e Admin Edge Used to define ports as end stations which prevent bridging loops in the network o True configures it as an End port e Admin Non Stp The port includes the STP mathematic calculation True is not including STP mathematic calculation false is incl
30. ercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SFP Modules Specification Voltage Range 12V 36VDC All Models _ All ESW508 Terminal Block Protection Shielded auto sensinc Ful Hal Duplex AA Negotiate 00Base FXO ss Distance 2 km Wavelength 1310mm_ Cable 62 5 125um TX power 23 5to 14dbm RX Sensitivity lt 35dbm A Connector Type Iert x J108BaeFX Distance 20 km Wavelength 1310nm Cable 9 125um TX power 15to 8dbm RX Sensitivity 35dbm ________ Connector Type SC III 2Mii GBICSFPPots o Conector Type IIe Material rm aa and Steel em Din Rail Panel B Manual Documentation Number ESW500series 0912m B8B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com SFP 1000SX M 550M T 1000Base SX Multi mode 550m LC Connector 40 to 85 C SFP 1000LX S 10KM T 1000Base LX Single mode 10km LC Connector 40 to 859C SFP 1000LX S 20KM T 1000Base LX Single mode 20km LC Connector 40 to 859C Enclosure See Dimensional Dimensions WxHxD Drawings 39 40 IEEE802 3 10Base T
31. eries 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Ping Test The Ping function implements the ping command to give users a simple but powerful tool for troubleshooting network problems The function s most unique feature is the ping command is entered from the user s PC the actual ping command originates from Managed switch itself In this way the user understands the LAN area being tested To use the Ping function enter the target IP address use the default settings or add your desired information then select Start Test Scan Network Scan Network Start Scan Ping Test E e Bytes Range 6071480 Intervak 1000 Milliseconds Range 100 5000 5000 milliseconds Range 1000 5000 Once the ping test is started the following results will be displayed Ping Result PING 10 1 0 178 10 1 0 178 56 data bytes 64 bytes from 10 1 0 178 icmp seq 0 ttl 64 time 0 6 64 bytes from 10 1 0 178 icmp seq 1 ttl 64 time 0 5 64 bytes from 10 1 0 178 icmp seq 2 ttl 64 time 0 5 ms 5 5 ms ms ms ms 64 bytes from 10 1 0 178 icmp seq 3 ttl 64 time 0 64 bytes from 10 1 0 178 icmp seq 4 ttl 64 time 0 10 1 0 178 ping statistics 5 packets transmitted
32. ettings The IP Settings page allows two methods of network address configuration DHCP or static DHCP Setup e Use down arrow key to IP Settings select Enter e Select 1 Obtain IP address Automatically DHCP select Enter e The confirmation window will open Select Yes Static IP Address Setup Use down arrow key to IP Settings select Enter Select 2 Use the following 1P Address Fixed 1P select Enter Add IP address Subnet Mask Default Gateway The confirmation window will open Select Yes B amp B Electronics HyperTerminal l x File Edit View Call Transfer Help D ls Fac 2 1 Obtain an IP Address Automatically DHCP ME Use the following IP Address Fixed IP IP Address 192 168 118 100 Subnet Mask 250 2990 299 0 Default Gateway 192 168 118 1 Primary DNS D l IV D ID lQ l l IV IC IC IC l Cy l IV IC D l lQ NI TT VI VRAN 7 7T 731 3 15 1 u y lu id IC IV l lQ 1 7 DN IW e h ON y W Y du AM n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n Up key Up Down key Down Left key Left Right key Right Confirm Enter B amp B Electronics All Rights Reserved Connected 0 07 04 ANSIW 115200 8 N 1 SCRC CAPS MN 12 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink
33. h 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com ESW516 Series Front Panel Fiber Link Activity LED 100BaseFX SC Fiber Port Fault Relay 10 Ground Screw 11 Input Power Terminal Block 1 Console Port 2 System Ready 3 Power LED 4 10 100BaseT X RJ45 Ports 5 Link LED 6 Speed LED 7 8 9 gt B STA O O REJ ELECTRONICS SPD BET 3 1130 O L14 1150 O L16 10 11 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com LED Description te EE PWR Green Power Applied No power Green System Ready STA Off System down reen Off 10 100 C SPD LED Green 100Mbps Off 10Mbps 10 100 Copper LNK LED Blinking Activity Off Not connected to network Green Link Fiber LED Blinking Activity Off Not connected to network 10 100 1000 Copper SPD LED 0 100Mbps 10 100 1000 Copper LNK LED SFP Port LED Blinking Activity Off Not connected to network Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd
34. information on the World Wide Web using default port 80 Https is a URL that implements a Secure HTTP connection using default port 443 All entered access IP Addresses must be a legal IP address Accessible IP addresses cannot be broadcast address or net mask for example 255 255 255 0 Each switch is allowed up to ten accessible IP addresses When this feature is enabled at least one of these IP addresses must be in the same subnet and a member of VLAN 1 for management changes By default all ports are members of VLAN 1 Port Each port can be individually configured to meet communication reguirements using Mode Flow Control and MDI MDIX Basic Settings Port Settings Copper u d ia Auto MDI MDIX ei B lt q lt lt q q lt 100WMbps Full Duplex 100Mbps Half Duplex 10Mbps Full Duplex 10Mbps Half Duplex Setting Description Default value Media Type The type of media copper or fibber Copper or Fiber The transmit speed between two Mode nodes Auto Negotiation Managing data transmission Flow Control between two Nodes Enable Medium dependent interface of MDI MDIX nodes Auto MDI MDIX Enable Enable port configuration options Disable IP Setting There are two options that can be used to configure the network settings of the Ethernet managed switch DHCP and Fixed Static IP Address DHCP will allow a DHCP server to automatically assign an IP Address setting The Fixed Static IP Address setting al
35. lows the user to manually configure the IP Address Subnet Mask and Gateway settings Home gt Basic Settings gt IP Basic Settings IP Settings Obtain an IP Address Automatically DHCP C Use the following IP Address Fixed IP Overview Basic Settings System Info Password IP Address Accessible IP Advanced Settings gt Default Gateway RingOn Trunking QoS IGMP Snooping Broadcast Storm Bandwidth 16 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Setting Description DHCP Fixed IP Network configuration The unique IP Address of the switch The range of logical addresses Subnet Mask within the address space Default The node that serves as an Gateway entrance to another network DNS Domain Name System DNS IP Address Default value Fixed Static IP 192 168 118 100 255 255 255 0 192 168 118 1 blank Note Incorrect Subnet Mask configuration may cause erratic RingOn functionality Time Setting Time Settings allows the user to select the appropriate Time Zone for his location The NTC Network Time Protocol synchronizes the clocks of computer systems over packet switched vari
36. nning Tree Protocol STP to provide faster spanning tree convergence after a topology change Rapid Spanning Tree Protocol will assist in network link failures by including spare redundant links to provide automatic backup paths Another basic function of RSTP is to prevent unintended loops and protect against broadcast storms RSTP Setup Redundancy Settings Redundancy Setting RSTP z Bridge Priority 32768 D Hello Time 2 Sec Range 1 10 Forwarding Delay 15 Sec Range 4 30 Max Age Time 20 Sec Range 640 Advanced Settings Port Configure RSTP Information RSTP Configuration Screen Redundancy Setting RSTP Bridge Priority 0 61440 Switches configured with the lowest numerical value have the highest priority and will operate as the root The value can be changed using multiples of 4096 Once the change is completed the switch must be rebooted Hello Time 1 10 Determines the frequency BPDU Bridge Protocol Data Units packets are transmitted BPDU packets are used to check RSTP current status Health of RSTP configuration Forwarding Delay 4 30 Number of seconds the port waits before changing from its Rapid Spanning Tree Protocol learning and listening states to the forwarding state Max Age Time 6 40 Number of seconds the switch waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration RSPT Information 20 Root Bridge Displays spanning tr
37. nooping 2 Port mirroring will reduce the switch performance Static MAC Address Forwarding Configuration The MAC address forwarding table will not only hold learned addresses but also up to 10 static unicast or 10 static multicast addresses Static addresses perform as learned addresses but are not subject to the aging process A normal or high priority can also be applied to messages containing the entered MAC address The action field can be toggled between Add and Delete The Static MAC Address field requires a valid input from the user it is not case sensitive When invalid addresses are entered the switch will display a warning message Table configuration e Select Add new Unicast or Multicast forwarding table e Add Static MAC Address to field e Select the desired port e Select add button 30 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Static MAC Address Forwarding Configuration add New Static MAC Address To Unicast Forwarding Table Add New Static MAC Address To Multicast Forwarding Table Unicast Forwarding Table Static MAC Address 02 8F 04 32 00 00 FF FF FF FF FF FF 102 3 G 4 OS OS Oz OSC oO 10 C 116 12 000 14 C 15
38. of paralleling more multiple ports between two switches The ability to configure this type of connection will increase the speed beyond the limits of a single port The multiple links between switches can also act as a redundant path if one port losses communication Limitations e Port 1 cannot be part of a Trunking group e Ports are not allowed to become members of multiple Trunking groups Trunking Settings k O KA Group 1 2 all al s l asli z g 9 7 Af 11 iz 13 14 15 16 17 is 19 20 21 22 23 24 J E 1 i3 4 s ie iz isepiertise impisr 13 1i4 15 16 17 18 19 20 21 22 23 24 L 3 25 26 E E QoS Quality of Service Quality of Service is a method of prioritizing Ethernet applications or device communications on a LAN Once a packet is received by the switch it can take persistence over other packets being received thus reducing latency and establishing a reliable method of data delivery Service quality features 4 different levels of queue high middle normal low High priority data packet stays in the switch for a short time The data packets are assigned priority levels in accordance to 802 1 priority tag and DiffServ priority tag settings QoS full wire speed mechanism can be configured using the relative priority and absolute priority QoS Setup QoS e Enable all QoS options become available o Port Priority o 802 1 Priority 802 1 P
39. pen the Command window by selecting the icon or in some operating systems the Run command line can be used to open the Command window by typing cmd and selecting enter Once the window is opened type telnet then the IP address of the unit as shown below Default IP address is 192 168 118 100 Select enter and the User Login screen will open Once the login screen opens follow the instructions listed under the Console mode section on the following page Command Prompt Microsoft Windows Uersion 6 1 76HH Copyright c gt 26869 Microsoft Corporation All rights reserved Cinlsers gt mbi5telnet 172 168 1185 1HH Console Mode Before the Managed switch is installed on a LAN the Console Mode feature can be used to change the network settings from the defaults Console Mode allows the configuration of the Managed switch network settings using an RS 232 connection through the RS232 Console port of the switch from a PC running a VT100 terminal emulation program such as HyperTerminal When the serial connection is made and HyperTerminal has opened the Console Mode screen will appear in the program window The serial port settings must be 8 N 1 at 115200 baud If Console screen does not appear select Enter z B amp B Electronics HyperTerminal lal x File Edit View Cal Transfer Help Ole 5 amp 0 Port Settings Bits per second 115200 Data bits e Parity None Stop bits 1 Flow control None
40. riority Settings o DiffServ Priority K DSCP Priority Settings o High Queue Preemptive Mode 24 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Port Priority e Two settings are available Normal and High When set to high packets have the lowest latency QoS Settings Enable Disable Port Priority Enable Disable 802 1p Priority C Enable Disable 8021p Priority Settings DiffServ Priority CO Enable 9 Disable DSCP Priority Settings MATAS C Enable 9 Disable E High gt Dom z 2 E 802 1p Priority The 802 1p header includes a three bit field for prioritization which allows packets to be grouped into various traffic classes 802 1p traffic is simply classified and sent to the destination e Choose Enable to start priority features based on 802 1p for each port Port Priority Enable C Disable 802 1p Priority Enable C Disable 802 1p Priority Settings DiffServ Priority C Enable 9 Disable DSCP Priority Settings AMET E C Enable 9 Disable Port Index Port Priority 802 1p Priority DiffServ Priority Enabled 7 2 Disable v 802 1p Priority Settings After selecting the 802 1p Priority Settings b
41. rity Settings which will allow a value 0 63 to be assigned to different gueues 26 Manual Documentation Number ESW500series 0912m B8B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com mem leas NZ ru 2 18 Normal zl 34 Middle so High m Ber Ei silus mi 20 Noma lm os masa so ron Bi ra Ms NE ma ER ra M 6 low xj 22 Noma zl 38 Middle 54 High E 7 Low sl 23 Noma gt 39 Midde zl ss High 8 Low z 24 Normal gt 40 Middle 56 High z mm Herm NA ma NE ra o iw ii 2 mua mon se na BEN 11 Low EH 27 Normal gt 43 Middle gt 59 High z 12 Low sl 28 Normal sl 44 Middle gt 60 High z 13 low Z 29 Noma zl 45 Middle zl 61 High ia w BR so maig 46 mam Hon BEN 15 low E 31 Normal gt 47 Middle gt 63 High z Setting Description Defaultvalue ea DiffServ QoS Settings Configure DiffServ priority 110 IGMP Snooping Internet Group Management Protocol IGMP Snooping provides a way to route multicast traffic and reduce unwanted traffic IP multicasting is commonly used when sending the same information to many receivers IGMP routes the multicast traffic to the correct devices and will not broadcas
42. rosoft Word Adobe Acrobat Snag It and other software Table of Contents Table of Contents Chapter 1 Introduction 1 OVERVIE V u uuu uu a nuna a a O RE RE unu nun y n 1 SR 1 PACKAGE CHECOIIS Toscar 1 ESW508 SERIES FRONT PANE cui 2 BOTTOM VIEW TT Tm 2 ESWG510 SERIES FRONT PANEL NEEN ENNEN EE E EN EEN EEN EEN ENEE AAA AEN ENN ENNEN E BOTTOM VIEW E 3 ESW516 SERIES FRONT PANEL EEN 4 BOTTOM VIEW osorno at 4 LED DESCRIPTION a ege 5 MOUNTING OPTIONS oscars ka a ee 6 Dimensional Drawing 6 Eege 6 ESWG510 SERIES cotorra ie ie 7 ESO EE 7 DC POWER CONNECTIONS uno tala lazi caracas arcanos 8 FAULT PI PPY u nunus kam ana yama a kanmam kaa aaa mana kaa ree 8 GIGABIT COMBO PORTS sisas rica da adi 8 DEFAULT SETTINGS 2 o s ssasassssasaasaqkaquasasasapaqanqaqaqasaqasaapasaqasqwaasqasaqqasqasawaascaaquaqasqaaaqasaqasquaqasqasquqha 8 Console Port DBO Male u u unu u AAA AAA AAA AAA RARAS 8 Sana C D OS PI DL L usoni usan uang tease 8 Wise SOLO Si 9 PeU SOCUL EE 9 ETHERNET PORT CONFIGURATIONS usccccccuccuccuccuseuseuseuseuseuseuseuseuseuseuseuseuseuseuseusautausuusausausansersersas 9 Chapter 2 Initial Setup Configuration 10 ZK 10 CONSOLE MODE ao erica acia aaa 10 Navigating Console MOG Sii A A AAA AAA 11 OVERVIEW aia 11 lode RR IC occidentalis dorada cantara E 12 DAG SO sila Cd HER 12 SAUC IP ae S8LIP uu ee ee ee ee EEE EAEE EIIE OEE EE EEEE ETA 12 FACTORY DEFAULT isosinasarasicaridsra rd daa drid ii
43. s 3 Factory Default 4 Logout Overview The Overview page displays the current switch IP address MAC address Firmware version configured name location and description e Select Enter to view information e Select Enter to return to main menu Default settings e IP address 192 168 118 100 e Subnet Mask 255 255 255 0 e Gateway 192 168 118 1 Manual Documentation Number ESW500series 0912m 11 B8B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com B amp B Electronics HyperTerminal D x File Edit View Call Transfer Help oel 5 3 dla el P n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n Fac la JO IC lQ la JO IC lQ Switch Name Managed Switch Switch Location Switch Description Managed Switch Contact Info IP ddress 192 168 118 100 HAC Address B0 10 16 18 12 80 Firmware Version Y1 00 03 Press any key then return 3 3 1 3 OA NI We ES EK IO e Eid i Iv l o o D IC l 3 70 239 le 36424 3 007073 7m 8 l l l l o l o lQ n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n Up key Up Down key Down Left key Left Right key Right Confirm Enter B amp B Electronics All Rights Reserved IP S
44. ser Index is used to select the individual users Home gt Basic Settings gt Password Basic Settings Password Settings Overview Basic Settings System Info Password Confirm Password ee Accessible IP se Comcel The maximum number of characters is 32 and a blank password can be configured If a blank password is used the log file will not trace the login of this user Accesable IP Two web server types are available HTTP and HTTPS When Access Control is enabled access to the managed switch web server is limited to the IP address listed on this page Connections from clients with other IP addresses will be refused Hama Banc Cethngs gt Beccezgbde EB Basic Settings Accessible IP Larra Settings Hart Se Elina Ni eine Lita D ams sau sana Ante Comirel E Enable C Guable Fi irst se e Ads atte lar o mri bri of r i Matic Mar Address a Forwarding Conii Bd reni raten HE urgeat KW arnin e Manual Documentation Number ESW500series 0912m 15 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com The web server connection HTTP Hypertext Transfer Protocol is a communications protocol used to transfer or convey
45. t the message to unintended devices IP multicast addresses are in the range of 224 0 0 0 through 239 255 255 255 Enabling IGMP allows the ports to detect IGMP queries report packets and manage IP multicast traffic through the switch IGMP have three fundamental types of message shown as follows Query A message sent from the querier IGMP router or switch asking for a response from each host belonging to the multicast group Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message Manual Documentation Number ESW500series 0912m 27 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Leave Group A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group IGMP snooping has been expanded overcoming some limitation of old versions It works with GMRP by sending GMRP notifications when PC s change port This will avoid multicast traffic lose IGMP Snooping Settings IGMP Snooping 19 Enable Disable IGMP Querier Enable Disable Query Interval 125 Sec Range 1255000 Multicast Age Time 300 Sec Range 125 5000 1 w2 v3 lv4 lv s 6 fe 7 v
46. uding the STP mathematic calculation Port Configuration 200000 200000 200000 200000 Port Cost E 200000 JU Ex E E Manual Documentation Number ESW500series 0912m 21 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com VLAN Virtual LAN A Virtual LAN commonly known as a VLAN are used to creating independent logical networks within a physical network Several VLANs may co exist within such a network VLAN s help in reducing the broadcast domain and aids network administrators by separating logical segments of a LAN that should not exchange data B amp B Electronics Managed switches support port based VLAN and 802 10 VLAN Port VLAN Setup The default Virtual LAN is VLAN 1 which all ports are members VLAN 1 operates as the management VLAN meaning at least one port must be a member of VLAN 1 to access and manage the switch VLAN 1 also allows the switch to operate as a standard switch Every port must belong to a VLAN and ports may belong to more than one VLAN ID B amp B Electronics Managed switches will support up to 26 port based VLAN groups VLAN Settings VLAN Port VLAN 802 1g VLAN Port VLAN settings il oj zk aF zk ek zk ak oke 1 10 W iiM 12 Iv 13 e ak 15 Iv iM 17 18 4
47. urope com ESW508 Series Front Pane B BSB ELECTRONICS Oo WA N 9 0su09 9 0su09 Z gt a N c D o O 5 10 11 Bottom View System Ready Redundant Power LED 10 100BaseT X RJ45 Ports Link LED A DC 12 36V AC 10 24V Speed LED 100BaseFX SC Fiber Port Fiber Link Activity LED Console Port Fault Relay 10 Ground Screw 11 Input Power Terminal Block MU PIT 10 11 2 Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com ESWG510 Series Front Panel B l SAOOO B amp B ELECTRONICS ajosuo sdq00ZSLL LN8 System Ready Power LED 10 100BaseT X RJ45 Ports Speed LED Link LED Fiber Link Activity LED 100BaseFX SC Fiber Port Input Power Terminal Block Ground Screw 10 Console Port 11 Combo RJ45 or SFP Port 12 Fault Relay x dur P LE a a Mi 1 B SAOOO B amp B ELECTRONICS 2 a B 3 H HE B SPD E LNK H osuoo ET ol Jo CH sdg0o0ZSLL LN8 Fault WIL uU 8 9 10 11 12 Bottom View DC 12 36V Manual Documentation Number ESW500series 0912m B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 P
48. utton the 802 1q Priority List window opens 802 1p establishes eight levels of priority The highest priority is seven used for network critical traffic five and six used for delay sensitive applications four through one used in controlled data applications streaming data The zero value is used as default no other setting is uses e 802 1p priority setting assign tag of 0 7 High Middle Low Lowest to each queue 1 el 2 el 3 5 High 6 Middle y 7 Middle comer come Web Server 1 0 4 Manual Documentation Number ESW500series 0912m 25 B amp B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B amp B Electronics Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com DiffServ Priority DiffServ or Differentiated Services is a computer networking architecture that specifies scalable and coarse grained mechanism for classifying managing network traffic and providing quality of service QoS guarantees on modern IP networks DiffServ can for example be used to provide low latency guaranteed service GS to critical network traffic such as voice or video while providing simple best effort traffic guarantees to non critical services such as web traffic or file transfers The Managed switch can classify traffic based on the DSCP field in the IP