1. once the AC utility power returns e Adapts automatically to 50 or 60 Hz input frequency e Visual and acoustic signals indicating operating mode and alarm conditions e Communicates with the Computer through serial RS 232 or USB communication port INSTALLATION INSPECTION AND PLACEMENT CHOICE Carefully remove LEONARDO from its packaging and carry out a meticulous inspection We recommend keeping the original packaging in case you need to send LEONARDO for maintenance purposes The following parts are fitted in the packaging e LEONARDO CARRIER Computer trolley complete with an anti sliding rubber carpet 4 wheels already mounted and fitted with LEONARDO PROTECTOR module inside e LEONARDO TIDIER rear column for housing and arranging all the Computer cables e Remote control with cable for the user to place in a comfortable position With this remote control it is possible to switch LEONARDO on off and control the working operations e AC power supply cable e 2 output cables We recommend paying attention to the below points in order to choose a correct placement for your LEONARDO e Place LEONARDO as close as possible both to the input electrical line and to the equipment to be supplied e LEONARDO is designed to operate in protected environments for example offices We therefore recommend installing it in a place with no humidity dust or smoke However for the environmental requirements please refer to the Specifications
2. IT IS ADVISED TO READ THIS MANUAL CAREFULLY AND TO KEEP IT Thank you for choosing LEONARDO INNOVATIVE POWER SYSTEM This manual is a guide which enables you to correctly install and use your LEONARDO INNOVATIVE POWER SYSTEM This manual includes important SAFETY instructions for the operator for the correct installation and gives useful advice on the product and battery maintenance For any type of problem please refer to this manual before calling the Technical Service From hereafter for simplicity the product will be called Leonardo IMPORTANT SAFETY INSTRUCTIONS e To ensure correct and safety operations it is necessary that operators and maintenance personnel observe the general Safety Standards as well as the specific instructions included in this manual e Electric Shock risk do not remove the cover LEONARDO contains internal parts at high voltage which are potentially dangerous capable of causing injury or death by electric shock e In LEONARDO there ate no parts which are subject to user s maintenance Any type of maintenance and repair must be carried out exclusively by a qualified technical personnel authorised by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded e Itis compulsory to ground LEONARDO according to Safety Standards in force e When LEONARDO is ON there are risks of electric shock at the output sockets e There are risks of electric shock at the output sockets if the unit is c
3. In addition the Easy Swap housing system allows Leonardo Protector module to be easily installed and replaced in a matter of seconds and in total safety Last but not least a remote control supplied with Leonardo Protector module which can be placed directly on the work surface permits control of all the Leonardo functions LEONARDO PROTECTOR module is a Line Interactive UPS Uninterruptible Power Supply specifically designed to protect your Computer from any type of irregularities in the AC line such as black outs over voltages low voltage micro interruptions which often cause damage to your Hardware and Software LEONARDO PROTECTOR is equipped with one RS 232 interface and one USB which can be used to notify a power failure or a low battery condition directly to a Computer During an extended black out this permits you to save your data automatically with the most widespread operating systems Windows Novell Linux etc LEONARDO PROTECTOR main characteristics ate e All functions are controlled by a microprocessor giving full guarantee on high reliability e Output Voltage regulation through AVR Automatic Voltage Regulation e Overload protection both in normal functioning and in battery mode e High performance battery charger which extends the battery medium life ensuring an optimal recharge e Starts up even if the electrical network is not available e Automatic restart after an automatic shut down due to a low battery condition
4. ailure on the electrical mains the UPS output outlets continue to supply suitable power to the connected devices SWITCH OFF To switch LEONARDO OFF it is enough to press the ON OFF button of remote control ALARMS BATTERY mode slow alarm When LEONARDO works in BATTERY mode it emits a sustained acoustic signal The alarm stops as soon as LEONARDO returns to a normal LINE mode functioning e ATTENTION in BATTERY mode LEONARDO emits an acoustic alarm signal every 10 seconds and simultaneously the ON OFF button of remote control flashes LOW BATTERY CONDITIONS fast alarm When LEONARDO operates in BATTERY mode and the remaining autonomy of the battery is around 20 30 it emits a sustained acoustic signal If the AC utility line is not restored LEONARDO continues working in LOW BATTERY condition until it switches off due to battery exhaustion of energy When the AC line returns LEONARDO switches on automatically and restarts working on LINE mode e ATTENTION in LOW BATTERY condition LEONARDO emits an acoustic alarm signal every 0 5 seconds and simultaneously the ON OFF button of remote control flashes OVERLOAD CONDITIONS continued alarm LEONARDO indicates an OVERLOAD condition through a continuing acoustic sound signalling In this case the user must reduce power within the specifications by disconnecting the appliances which cause the overload please refer to
5. ation OUPUT VOLTAGE REGULATION BATTERY 0 MODE a OUTPUT INVERTER WAVEFORM Modified Sinewave OVERLOAD ACCEPTED lt 130 CERTIFICATIONS CE BACK UP TIME 5 30 minutes depends on the load NOMINAL BATTERY VOLTAGE Vcc 12 SEALED MAINTENANCE FREE LEAD ACID 1 unit BATTERY 12V 7 2Ah RECHARGE TIME typical 8 hours AUDIBLE NOISE at 1 meter dBA lt 40 COOLING Natural WEIGHT Kg 14 DIMENSION W x H x D cm 21 x 68 x 66 including rear column Temperature 0 40 C Humidity 0 95 without condensation Maximum altitude 3000mt ENVIRONMENTAL SPECIFICATIONS RS 232 INTERFACE Included USB INTERFACE Included RJ11 RJ45 plug included FILTERED PHONE PLUG WARRANTY 2 years Technical data may change without prior notice LEONARDO REAR 1 AC inlet plug to connect LEONARDO to the AC utility line through the supplied AC power cable ll 2 Input thermal switch Circuit Breaker it goes off in 1 i i overload or short circuits condition push the external button of the Circuit Breaker to reactivate it Figure 1 COMPUTER CARRIER REAR SIDE ORO Figure 2 3 UPS outlet socket IEC type protects connected device from black outs 4 UPS outlet socket SCHUKO type protec
6. chapter and check that the selected place meets with such specifications e Itis necessary to leave at least 20 cm of space all around in order to permit reasonable ventilation e Do not obstruct ventilation holes and do not insert objects or liquids in the ventilation holes e Do not keep liquids flammable gases or corrosive substances near the unit INSTALLATION For a correct installation please carry out the following points 1 Insert LEONARDO TIDIER rear column for housing and arranging all the Computer cables in the proper runners present on the rear side of LEONARDO CARRIER This is a very simple operation and no tools ate necessary 2 Connect the remote control to the proper connector see figure 2 number 6 3 Through the endowed AC power supply cable connect LEONARDO to an AC utility line outlet It is mandatory to ground the outlet according to the Safety Standards Carefully check the grounding make sure that the utility power is available and that its range falls within LEONARDO specifications refer to the Specifications chapter For the connection use the input outlet fitted on the rear of LEONARDO see figure 1 number 1 4 Turn LEONARDO ON by pressing the front panel button of remote control and leave it in ON for at least 8 hours in order to completely re charge the battery Switch LEONARDO OFF by pressing again the front panel button of remote control Unplug LEONARDO from the AC line outlet Place t
7. d condition Technical Service support tecnoware com phone 39 55 8367554 In the event of a technical problem assessed onto LEONARDO indictable to the UPS internal module namely LEONARDO PROTECTOR the user will be able to easily extract LEONARDO Protector s module in just a few seconds and in total security thanks to the instructions given by the Technical Service over the telephone Besides thanks to the amazing innovative design the user may still use LEONARDO to feed its own workstation while the UPS is being repaired e ATTENTION in that case the protection guaranteed by the UPS module is missing protection in case of a black out stabilisation switching ON and OFF through the remote control etc consequently the workstation will switch off in the event of a black out SOFTWARE ON WEB Connecting to the Web site www tecnoware com it is possible to download free of charge LEONARDO management updated Software version for Windows Linux and Novell The connection between LEONARDO and Personal Computet is carried out through a standard RS 232 or USB cable optional MODEL LEONARDO INNOVATIVE POWER SYSTEM 1200 POWER CE Standards VA 600 NOMINAL INPUT VOLTAGE vV 220 230 INPUT VOLTAGE RANGE 20 25 INPUT OUTPUT FREQUENCY Hz 50 60 automatic selection INPUT FREQUENCY RANGE t5 NOMINAL OUTPUT VOLTAGE vV 220 230 OUPUT VOLTAGE REGULATION LINE By AVR MODE Automatic Voltage Regul
8. e FI Italy Phone 39 055 83 67 554 Fax 39 055 83 67 457 www service tecnoware com support tecnoware com U SI
9. e outlet according to the Safety Standards Carefully check the grounding make sure that the utility power is available and that its range falls within LEONARDO specifications refer to the Specifications chapter For the connection use the input outlet fitted on the rear of LEONARDO see figure 1 number 1 17 Turn LEONARDO ON by pressing the front panel button of remote control check that the power up performance takes place properly and that LEONARDO does not give any warning signals Make sure that all devices are turned ON accordingly FUNCTIONING SWITCH ON AND FUNCTIONING To turn LEONARDO ON it is sufficient to plug it to the AC utility line outlet and press the remote control ON OFF button LEONARDO emits an acoustic signal illuminates with a blue light the ON OFF button and begins working in LINE mode When working in LINE mode the ON OFF button is always illuminated e ATTENTION LEONARDO automatically switches to the BATTERY BATTERY mode whenever the Mains voltage amplitude is out of the safety limit due to black out surge over under voltage e ATTENTION LEONARDO is gifted with 3 UPS output outlets see figure 2 number 3 and 4 and one filtered output outlet for protection against spike and surge see figure 2 number 5 This outlet protects the connected devices against overvoltages and any disturbances on the electrical network but does not supply electricity in case of a black out If there is f
10. he Computer above LEONARDO on the anti sliding carpet Remove the top part of the column which is made of 2 plastic parts Firstly remove the front plastic part the smaller one and then remove the rear part oD ND wy Fit all the Computer cables feeding cables peripherals cables data cables remote control cable etc inside the column using the slots on the plastic and mobile parts of the column 10 Use LEONARDO output outlets for feeding the Computer and peripherals Refer to figure 2 ATTENTION the output outlets marked with numbers 3 and 4 are the UPS output outlets so they will continue to supply power in case of a black out while the output outlet marked with number 5 the edge is in Silver colour is ONLY A FILTERED output IT IS NOT an UPS output outlet do not feed any critical device through this outlet 11 Reassemble the rear plastic part closing the column then remount the front plastic part sliding it from the top to the bottom paying attention that the lodged cables in the column come out in an orderly way from the prearranged circular holes 12 Place LEONARDO in the chosen position 13 Block the wheels with the proper brake 14 Connect in a suitable way all the cables that come out of the column 15 Place the switch of all the devices connected to the LEONARDO output outlets in the ON position 16 Through the endowed AC power supply cable connect LEONARDO to an AC utility line outlet It is mandatory to ground th
11. onnected to the AC utility line e Do not insert objects or pour liquids in the ventilation holes Do not keep liquids flammable gases or cortosive substances neat LEONARDO e Install LEONARDO indoors in a protected clean and moisture free environment LEONARDO INNOVATIVE POWER SYSTEM leonardo Carrier Pay Leonardo Tidier Leonardo Protector LEONARDO INNOVATIVE POWER SYSTEM BRILLIANT SIMPLY BRILLIANT Three independent modules to tidy up and fully protect your Computer station Better arrangement for cables and peripherals Great security and protection for your Server and Personal Computer LEONARDO CARRIER Is the heart of the entire system a solid base in metal and ABS fitted with wheels that perfectly integrate with your Personal Computer or Network Server Leonardo Carrier is equipped with electrical sockets for an easy and safe connection of your Computer and the entire workstation to the mains via a single cable to be inserted in the plug socket LEONARDO TIDIER Is an elegant column in metal and ABS to be connected to Leonardo Carrier module which will tidily hold and protect all your workstation Computer and peripherals cables including all the accessories LEONARDO PROTECTOR This module is to be inserted in a special compartment of Leonardo Carrier transforming it into a real UPS able to filter stabilize and supply alternative power in case of a power cut or at any time when necessary
12. the Specifications chapter In case of OVERLOAD LEONARDO may automatically switch off protecting itself from this anomalous situation TROUBLESHOOTING PROBLEM POSSIBLE CAUSE HOW TO RESOLVE LEONARDO does not ON OFF button of the remote Press the ON OFF button of the remote control continuously for at least 2 seconds turn on control Remote control connection Check that the remote control is correctly connected to LEONARDO see figure 2 number 6 Battery is flat Recharge the battery for at least 6 hours Electronic board failure Refer to Technical Service LEONARDO always Input mains power cable is Check the input mains power cable function in BATTERY disconnected Check AC utility line mode Control the thermal switch Circuit Should the Circuit Breaker release check if LEONARDO is overloaded and eventually Breaker on the rear side see figure reduce the load then try to restore the Circuit Breaker by pressing on the released part 1 number 2 Black out conditions surge Over or Under voltage Wait until utility power returns to normal conditions Electronic board failure Refer to Technical Service Battery Autonomy is too Battery is not fully charged short Recharge the battery for at least 6 hours Electronic board failure Refer to Technical Service Continuing Acoustic signal OVERLOAD condition Disconnect all devices which cause the overloa
13. ts connected device from black outs 5 Filtered outlet socket SCHUKO type with silver colour edge MAXIMUM POWER 1500 Watt 8 Ampere ATTENTION IN CASE OF A BLACK OUT THIS OUTLET IS NOT PROTECTED DO NOT FEED CRITICAL DEVICES THROUGH THIS OUTPUT 6 Remote control connector to connect the cable of the remote control 7 USB communication port 8 RS 232 communication port 9 RJi1 RJ45 phone plug to protect and filter the telephone line C EUROPEAN DIRECTIVES CONFORMITY C Tecnoware confirms that LEONARDO INNOVATIVE POWER SYSTEM complies with the requirements set out in the Low Voltage Directive Safety 73 23 EEC and following amendments the EMC Electro Magnetic Compatibility Directive 89 336 EEC and following amendments The following Standards were applied Low Voltage Directive Safety EN50091 1 1 1996 EMC Directive Electro Magnetic Compatibility EN50091 2 1995 Copyright 2005 TECNOWARE s r l All right reserved LEONARDO CARRIER LEONARDO PROTECTOR LEONARDO TIDIER are brands registered by TECNOWARE s r l All trademarks are property of their respective owners LEONARDO INNOVATIVE POWER SYSTEM is patented by TECNOWARE s r l Edition July 2005 Version 1 0 1 Leonardo Innovative Power System USER S MANUAL cy TECNOWARE power systems B U www tecnoware com CLAS ES S TECNOWARE power systems www tecnoware com Tecnoware Srl Via Lisbona 9 50065 Pontassiev