Home

USER MANUAL - Video

image

Contents

1. The insert kit for TBUS 4 P N 800 000031 can replace a power socket in the inner frame see Section 5 1 3 TBUS 4 IF 2xPS INSERT P N 80 003699 2 power sockets 2 blank inserts 1 pass through insert The insert kit for TBUS 4 P N 800 000031 can replace a power socket in the inner frame see Section 5 1 3 Custom made inner frames can be designed if required Contact Kramer Electronics for more details TBUS 4 Your TBUS 4 Enclosure 4 3 Power Socket Options A choice of one or more power sockets per inner frame is available in several versions including power sockets for the USA Germany the Europlug Belgium France Italy and Australia A Universal socket for general use is also available see the compatibility restrictions in the table below as well as Legrand manufactured sockets the Mosaic series only which comes in white that are suitable for various countries Single Power Socket Assemblies Power Specs Universal TBUS PS UNIV 80 000899 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France you should order country specific sockets instead Not compatible with South African plugs USA
2. 123 2mm 225 2mm Figure 5 Cut out Dimensions 4 Unscrew and remove the template from the surface of the table and clean the table surface Take care not to damage the table If needed you can download a full scale template from our Web site Kramer Electronics is not responsible for any damage caused to the table 5 4 Inserting the TBUS 4 through the Cut Out Opening To install TBUS 4 in the opening 1 Remove the protective rubber guard from around the outer rim of the TBUS 4 housing Beware of the sharp edge 2 Carefully insert the unit into the prepared opening see Figure 6 3 Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit see Figure 2 item 7 4 Verify proper alignment of the unit before tightening the mounting screws 5 Screw both mounting butterfly screws upward until they reach the table surface from underneath Tighten firmly see Figure 6 6 Screw the locking butterfly screws downward until tight against the mounting bracket Figure 6 Inserting TBUS 4 into the Prepared Opening TBUS 4 Installing the TBUS 4 5 5 Connecting the Pass through Cables To insert the pass through cables for example to connect a laptop do the following see Figure 3 1 Remove the two screws attaching the split pass through bracket 2 Remove the split grommet 3 Insert the cable through the rectangular opening 4 Open the s
3. Optional Insert Kit for TBUS 4 Figure 5 Cut out Dimensions Figure 6 Inserting TBUS 4 into the Prepared Opening Figure 7 TBUS 4 Boardroom Installation Oo NOJAA DB NNN TBUS 4 Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Thank you for purchasing the Kramer TBUS 4 which is ideal for boardrooms conference and training rooms 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables Go to http www kramerelectronics com to check for up
4. Section 5 5 6 Connect the cables see Section 5 6 7 Adjust the height of the inner frame see Section 5 7 5 1 Assembling the Inner Frame The modules mounted on the inner frame can include single inserts and or dual inserts as well as a power socket in some models This section describes how to assemble these modules Each module kit comes with detailed assembly instructions 5 1 1 Mounting the Inserts You can rearrange or remove any of the plates mounted on the Inner Frame and replace them with Kramer passive wall plates or connector modules for interfacing ANN type signals To mount a Kramer insert or connector module 1 Unscrew the two screws that fasten the blank plate to the inner frame and remove the blank plate 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them Figure 3 TBUS 4 Inner Frame P N 80 003699 Feature Function 1 Power Socket Opening Suitable for a single power socket or the optional insert kit for TBUS 2 Blank Plates Two blank covers that can be replaced with wall plates as required Split Grommets Push apart slightly to insert cables ral Split Brackets Support the split grommet for the pass through cables ea Adjustable Height Screw For adjusting the height of the inner frame 4 Holes 5 1 2 Mounting the Power Socket Assemblies To mount the power socket place the power socket under the f
5. TBUS PS US 80 000999 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Germany and EU TBUS PS DE 80 001299 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Belgium and France TBUS PS FR 80 001399 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS PS ITALY 80 001499 100 240V AC 50 60Hz 5A Maximum 5A per power outlet TBUS 4 Your TBUS 4 Enclosure Single Power Socket Assemblies Power Specs Australia TBUS PS AUS 80 001599 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Legrand manufactured sockets for various TBUS PS LEGRAND 80 001799 countries For example the Legrand assembly with a UK power socket 100 240V AC 50 60Hz 5A Maximum 5A per power outlet 4 1 Power Cord Options You can order any of the following power cords to use with the TBUS Power Cord Type Description P N 110V North America AC POWER CORD 6ft 110V 91 000099 125V Japan POWER CORD JAPAN 6ft 125V 91 000699 220V Europe Right Angle AC POWER CORD RA 6ft 220V 91 000199 220V Israel AC POWER CORD ISRAEL 6ft 220V 91 000999 TBUS 4 Your TBUS 4 Enclosure P 5 Installing the TBUS 4 To install the TBUS 4 perform the following steps 1 Assemble the Inner Frame see Section 5 1 2 Install the Inner Frame see Section 5 2 3 Cut an opening in the table see Section 5 3 4 Insert the unit through the opening and secure to the table see Section 5 4 5 Connect the pass through cables
6. in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Resident
7. HL non condensing RANGE STORAGE TEMPERATURE 20 to 70Deg C RANGE STORAGE HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS Top plate 243mm x 140 4mm 9 6 x 5 5 W D Enclosure 203mm x 102mm x 130mm 8 0 x 4 0 x 5 1 W D H WEIGHT TBUS 4 0 88kg 1 948lbs approx Table clamps 0 25kg 0 6lbs ACCESSORIES Power cord six self locking ties template template screws OPTIONS Inner frames passive wall plates and interfaces power socket kits power cord optional insert kit for TBUS P N 800 000031 Maximum 5A per power outlet Specifications are subject to change without notice at http www kramerelectronics com TBUS 4 Technical Specifications of the Assembled TBUS 4 LIMITED WARRANTY We warrant this product free from defects in material and workmanship under the following terms HOWLONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHATIS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by us or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectro
8. KRAMER ELECTRONICS LTD USER MANUAL MODEL TBUS 4 Table Connection Bus P N 2900 300067 Rev 1 TBUS 4 Quick Start Guide This page guides you through a basic installation and first time use of your TBUS 4 For more detailed information see the TBUS 4 user manual and modular instruction sheets You can download the latest manual at http www kramerelectronics com Step 1 Check what s in the box z TBUS 4 Table Connection Bus Enclosure A 1 Cut out Template K 2 table clamps A 1 Quick start guide 6 self locking ties 1 User Manual Step 3 Prepare the table for mounting Cut out an opening in the table using the cut out template Step 4 Install the TBUS 4 to the table Contents 1 Introduction 2 Getting Started 2 1 Achieving the Best Performance 2 2 Glossary 3 Overview 4 Your TBUS 4 Enclosure 41 TBUS 4 Optional Inserts 4 2 TBUS 4 Optional Inner Frames 4 3 Power Socket Options 41 Power Cord Options 5 Installing the TBUS 4 5 1 Assembling the Inner Frame 5 2 Installing the Inner Frame 5 3 Cutting an Opening in the Table 5 4 Inserting the TBUS 4 through the Cut Out Opening 5 5 Connecting the Pass through Cables 5 6 Connecting the Cables 5 7 Adjusting the Height of the Inner Frame 6 Using the TBUS 4 7 Technical Specifications of the Assembled TBUS 4 Figures Figure 1 TBUS 4 Inside a Table Figure 2 TBUS 4 Enclosure Top View Figure 3 TBUS 4 Inner Frame P N 80 003699 Figure 4
9. e the TBUS 4 is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 7 Video Conference Kramer Switcher Scaler Display Ethernet Power Amplifier with Speakers Computer Graphics Source Laptop Projector Figure 7 TBUS 4 Boardroom Installation TBUS 4 Using the TBUS 4 EET 7 Technical Specifications of the Assembled TBUS 4 POWER SOURCE Power Socket Assemblies AC power limits Universal 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Fully compatible with power plugs in the UK India Italy and Denmark as well as with the 2 prong Europlug Partially compatible if the polarity is reversed with plugs in China Switzerland Israel and the USA The universal socket does not supply grounding to plugs in Central Europe and France you should order country specific sockets instead Not compatible with South African plugs USA 100 240V AC 50 60Hz 5A pe an ger Germany and EU 100 240V AC 50 60Hz 5A pom tert Belgium and France 100 240V AC 50 60Hz 5A permet an tere South Africa 100 240V AC 50 60Hz 5A po an hte tt Australia 100 240V AC 50 60Hz 5A pes tem egret Legrand manufactured 100 240V AC 50 60Hz 5A sockets for various countries Mosaic Series FUSE RATING T 6 3A 250V OPERATING TEMPERATURE 5 to 45 Deg Centigrade RANGE OPERATING HUMIDITY 10 to 90 R
10. hrough available in black and brushed clear note that other customized colors can also be ordered e Aninner frame that can be set to one of four possible height adjustments Note that the inner frame is ordered separately e Power socket openings that are suitable for any of the following power sockets for the USA Germany the Europlug Belgium France Italy Australia Universal for use anywhere see compatibility restrictions in Section 7 or Legrand type power sockets for use with Legrand s white Mosaic series only Order the power sockets separately from Kramer Electronics e An optional insert kit to replace one power socket The insert kit can include two wall plate module inserts two cable pass through connectors or one of each TBUS 4 is height adjustable and the cover opens and closes manually keeping the cables and the connectors out of sight when not used Figure 1 TBUS 4 Inside a Table Do not place heavy objects on top of the TBUS 4 TBUS 4 Overview 4 Your TBUS 4 Enclosure Figure 2 TBUS 4 Enclosure Top View Feature Function 1 Black Brushed Clear Includes an opening for cable pass through covers the Inner Textured Lid Frame leaving the table surface neat and tidy 2 Outer Rim Fits over the table surface A protective rubber guard protects the outer rim during shipping Remove it before installing the unit Inserted into the table cut out 4 Rubbe
11. ial commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION IP Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment IP Use the supplied DC power supply to feed power to the machine IP Please use recommended interconnection cables to connect the machine to other components FCC andCE approved using STP cable for twisted pair products For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Disconnect the unit from the power m supply before opening and servicing
12. nics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removalorinstallation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FORAND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included
13. plit grommet slightly and insert the required cables 5 Place the split bracket around the grommet and position this assembly over the Inner Frame 6 Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the inner frame 7 Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure 5 6 Connecting the Cables When replacing blank inserts with connector inserts for example VGA audio HDMI and so on or connecting the TBUS 4 IF 2XPS STAND P N 80 003599 inner frame 1 Insert the cables to their appropriate connectors from underneath 2 Secure the cables to the tie holes using the included self locking ties Do not secure the cables too tightly or too loosely Leave a small amount of slack After the TBUS 4 is connected to mains power and the proper cables it is ready for use TBUS 4 Installing the TBUS 5 7 Adjusting the Height of the Inner Frame If needed you can adjust the inner frame to one of four possible heights to accommodate large or bulky cables To adjust perform the following 1 Remove the four height adjustment screws two screws on each side while supporting the surface from underneath with your fingers 2 Raise or lower the inner frame to the required height insert the screws and tighten them in place TBUS 4 Installing the TBUS 4 6 Using the TBUS 4 Onc
14. r Protect the table surface when mounting the unit one on each Protectors side e Locking Butterfly Tighten to lock the mounting butterfly screw one on each side Screws D 2 D a E 5 Mounting Tighten to secure the unit to the table surface one on each side o Butterfly Screws gt GI e H Mounting Fit in the bracket slits after inserting the enclosure into the table Brackets to secure the unit to the table surface one on each side eight Adjustment The screw holes on each side panel are used for adjusting the Screw holes height of the Inner Frame 4 height adjustment screws are included racket Slits Located on the front and rear panels and on both sides of the unit For attaching the two mounting brackets on opposite sides 10 Tie Holes Insert the self locking tie through the holes to fix the pass through cables to the inside walls of the unit 8 pairs of holes 4 for the front panel and 4 for the rear panel 4 1 TBUS 4 Optional Inserts You can install any wall plate devices as well as any of the single or dual inserts see our Web site for details 4 2 TBUS 4 Optional Inner Frames The following inner frames can be installed in the TBUS 4 enclosure Inner Frames for TBUS 4 Specifications define what you can include in this inner frame TBUS 4 IF 2XPS STAND P N 80 003599 2 power sockets 2 RJ 45 connectors 2 USB connectors 2 3 5mm mini jack AUDIO connectors 2 VGA 15 pin HD connectors
15. rame in its appropriate place and tighten with the two screws supplied Power socket kits come with assembly instructions 5 1 3 Mounting the Optional Insert Kit for TBUS 4 You can mount the insert kit P N 800 000031 in place of mounting a power socket To do so place and align the Kramer insert under the opening insert the two screws supplied with the kit to fix the Kramer insert in place and tighten them Figure 4 Optional Insert Kit for TBUS 4 5 2 Installing the Inner Frame To install the inner frame 1 Place the inner frame inside the TBUS 4 enclosure 2 Set the required height using your fingers to bring the inner frame to the desired position screw and tighten it in place using the height adjustment screws supplied with the inner frame Inner Frame kits come with assembly instructions KHN TBUS 4 Installing the TBUS 4 5 3 TBUS 4 Installing the TBUS 4 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template that is included with your TBUS 4 on the surface of the table exactly where you want to install the TBUS 4 2 Attach the template to the table with the included screws if using the cut out template 3 Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 5 not to scale The thickness of the table should be 76 2mm 3 inches or less
16. to date user manuals a complete list of Kramer wall plates and module connectors application programs and to check if firmware upgrades are available where appropriate 2 1 Achieving the Best Performance To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position your Kramer TBUS 4 away from moisture excessive sunlight and dust 2 2 Glossary Inner frame The inner frame fits into the TBUS enclosure Legrand socket For use with Legrand s white Mosaic series only Universal socket The Universal socket fits almost all power cords worldwide Insert The insert is fitted in the inner frame Go to our Web site to check for a variety of single and dual sized inserts 3 Overview The Kramer TBUS 4 is a high quality anodized aluminum table mounted connection bus for boardrooms and conference rooms Its attractive enclosure is designed to provide maximum connectivity in the smallest possible footprint The unit is sturdy cost effective and easy to install TBUS 4 features e A modular design letting you tailor the TBUS 4 according to your requirements e A brushed aluminum lid with a special opening for cable pass t

Download Pdf Manuals