1. alsles Specifications Air AT E Operating power 9V alkaline battery 3 Emitting distance gt 100m in open area I Service life lt 1 year Monitoring range 20m Wireless outdoor siren Features Nice exquisite and waterproof e Mico computer controlling steady performance and high class quality e Study to at most 10 pcs of wireless alarm host e With built in backup battery Low standby power consumption self inspection of lower battery voltage automatic charging www usmartbuy com Wall hanging installation Fixed ecrevk le si Specifications e Operating power 110 240VAC 50Hz Backup battery E Study Waon Static power consumption lt 40 mA on off button red e Working power consumption lt 450 mA Receiving distance gt 100M In open IES I Speaker of i alarming a Hanging hole 9 Flashing area Alarming volume gt 110db Installation and usage Press down the green power switch at the back after connecting the siren to the AC power Study the siren to the alarm host according to the instruction Unplug from the AC power fix it in the proper outdoor place with handing hook and then plug to the AC power How to reset unregister Keep pressing the red button for 10 seconds and release a successful deactivation will be followed by a flash of the alarming light O Control Host Specifications Working power AC 100 230V DC 12V 1A Static current lt 50mA
2. disarming by SMS Adjust alarm host s installation position to get the good signal strength The host does not alarm after the Caused by the functions of arm Armed Away mode alarm goes off when detector is triggered in arm state mode Armed Away and Armed any sensor is triggered Home Armed Home mode alarm goes off when Have already setup time for Entry any sensor in Perimeter zone is triggered Delay or Exit Delay and it won t alarm when any sensor in Alarm sound has been turned off Motion zone is triggered Program to adjust the time for Entry Delay or Exit Delay Turn on the alarm sound according to section G The PIR sensor doesn t work Not properly connected to the Open the sensor shells to install the batteries power well and slide the power switch to On Jumper problem SS detect once every 5 seconds Coding un matched with the SMIN detect once every 5 minutes Learn the PIR to the control host control host The detecting distance of PIR The ambient temperature in the When the ambient temperature in the detecting sensor gets shorter detecting area is too high area exceeds the human body temperature the detecting distance will get shorter it s normal the transmission distance of detector to panel shorten a nearby emitter is sending code move one detector next to panel and try Panel receiver stoppage identify the interfering source and eliminate standby battery of th
3. when not charging Alarm current lt 500mA Built in Li Ion backup battery 3 7V 800mAH rechargeable Backup battery standby around 24 hours charging time 12 hours 2 Band GSM GSM900 1800Mhz GSM transmit power 2W Linear Transmission Distance 250m in open air Receiving and emitting frequency 433 MHz Working condition Temperature 10 C 50 C Humidity lt 80 P Troubleshooting Probable Reasons Available Solutions Cannot dial for alarm No arming Do arming operation Alerting phone unsetted Re set according to the specification Parts improperly installed Coordinating the location of parts e Code no match Re coding SIM card overdue Pay to the SIM card Turn off SIM card PIN code The control host can t record Did not keep pressing the record Keep pressing the record button all the time Me button all the time while recording while recording No external power to the control host Connect the power adapter to the control host www usmartbuy com Repeatedly receiving the alarm Fail to operate according to the Follow the instructions after answering the telephone operation instruction of the telephone alarm phone calls and hearing the recorded alarm message Can t receive alarm SMS SIM card is not insert properly Insert SIM card properly message or can t receive SMS SIM card message storage 1s full Clear messages which stored in the SIM reply message after arming or GSM signal is not good enough card
4. 0 silent or 1 audible Input phone sound Sensors in big blue box have Program wireless 7 gt X gt ENT gt YY gt X 0 add or I delete been sensors ENT YY Zone number includes 00 15 programm ed to the control host On Off of door amp window state check can only use 9 gt X gt KENT X 0 closed or 1 open with our intelligent sensors If upload arm amp si disarm to 5 gt X gt ENT X 0 not upload or 1 upload management monitoring center 8 gt 0 gt ENT gt XX E User Code X X X X 4 digit user code No code X X gt ENT Note Press ll to exit from the programming state after finishing programming www usmartbuy com K How to Change Alarm Password SET gt Programming LED light up if it does not light up please press ESC button first and then press SET button again gt 999999 gt ENT gt Six Digital New Programming Passwords gt ENT gt Six Digital New Programming Passwords gt LENT gt sounds long Di Di from the alarm host indicates successful operation L Extended functions 1 Separate arm and disarm of 8 wired zones When the host is armed press 1 8 number key can arm disarm the corresponding zone Status light of the corresponding zone on indicates armed off indicates disarmed M Wireless Zones Sensor Type Zone Type Applicable Sensor Name Supports upto Wirele
5. off registered sensor and start from again to register another sensor we z mi e ee Vv Mii a ra i k 4 j J n i a Pal oh EJ iv Register panic button to the control host Zone 01 is used for panic button Each zone can learn 4 sensors Make sure the control host is in disarmed status and Press SET gt Programming LED light up if it does not light up please press ESC first and then press SET again gt Input Password default 888888 and press ENT gt Press 7 gt Press O gt Press ENT gt Input 01 and press ENT gt Learn LED lights up gt Press the button twice successively gt when hear long Beep from the control host and see the Learn LED flashes and then off this means the sensor learning is successful After that please turn off registered sensor and start from again to register another sensor www usmartbuy com v Register smoke detector to the control host Normally zones 01 to 05 are used for smoke alarm Each zone can learn 4 sensors Remove the back bracket and open the cover to install the battery gt Make sure the control host is in disarmed status and Press SET gt Programming LED light up if it does not light up please press ESC first and then press SET again gt Input Password default 888888 and press KENT gt Press 7 gt Press 0 gt Press ENT gt Input Zone Number can be zone number between 01 and 05 and press
6. LENT gt Learn LED lights up gt Press and hold the testing button twice successively gt when hear long Beep from the control host and see the Learn LED flashes and then off this means the sensor learning is successful After that please turn off registered sensor and start from again to register another sensor Working Light Air Holaa y if DE Test Button E Unregister Deactivate Sensors to the Control Host 1 Sensor Command 71 gt 1 gt ENT gt YY gt ENT Where YY Zone number includes 00 15 Make sure the control host is in disarmed status Press SET gt Programming LED light up if it does not light up please press ESC first and then press SET again gt Input Password default 888888 and press ENT gt Press 7 gt Press 1 gt Press ENT gt Input Zone Number and press ENT gt when hear long Beep from the alarm host the operation is successful Please note all sensors registered on that zone will be deleted 2 Indoor siren Plug the indoor siren into the power gt Press down and hold the learning button at the side for 15 seconds and release gt the LED in the siren flashes once 3 Outdoor siren Connect the power to the outdoor siren gt Keep pressing the red button for 10 seconds and release gt a successful deactivation will be followed by a flash of the alarming light www usmartbuy com F Preset Phone Numbers into the Con
7. Quick Installation Manual LED GSM Wireless Alarm System By shield4u http www usmartbuy com Version 20120827 www usmartbuy com A Alarm Understanding GSM Antenna li 1 2 3 4 5 6 7 8 9 F oa ES Emergency Back Space Number Esc Disarm POWER Power r Hanging Hole Arm Away GSM ALARM SYSTEM Arm Home Status Indicator A C 4 Signal Indicator eT De TO Low Power Indicator a i Ead r an q N 4 A 2 Confirm Record Play Program ON OFF ON Mic Battery Recording on off Siren A Hanging Hole SIM Card Slot 4 CE Home OJ Emergency la www usmartbuy com Short Beep twice Error in command or failed operation Buzzer A Successful in command or successful Long Beep once or twice operation Always lit Defense zone alerting LED Defense Zone Emergency alarm i Always lit Emergency alerting LED ne GSM module and SIM card working Blinking every 5 second properly Signal Indicator Always lit GSM signal weak or SIM card not found Blinking every 1 second GSM signal weak or SIM card not found Low Power Always lit The internal backup battery is low Indicator B Manipulation Specification 1 Zone types and definitions i Perimeter zone zone number 06 10 Generally is used for wireless door window gap sensor ii Motion zone z
8. V alkaline battery Emitting distance gt 100m in open area Service life lt 1 year e Alarm Distance lt 4cm o Installation and Usage Fix the part of magnet onto the door frame in a position of 1 6m above the ground to prevent any children from bumping onto it Fix the part of emitting onto the door frame make sure to keep the part of magnet and part of emitting in parallel the space between the two parts shall be less than 10mm Upon the working light flashes frequently in blue please replace the batteries Wireless Wide Angle PIR Sensor Working Light 2 O 4 Low Votage Light Di Power Switch Down Off Up On Lens O Learning Emitting Switch O O 430 UO i Jump Line 123 Fixthe PIR by pushing it downwards Installthe bracke Keep the switch on Features Mainly monitor and control indoor stereoscopic space generally set in Motion Zone e When human body enters into the detecting area the sensor will transmit the alarm signals to the alarm host Specifications Operating power 9V alkaline battery Emitting distance gt 150m in open area www usmartbuy com Service life lt 1 years Detecting distance 110 10x10m Installation and Usage e Fix the bracket on suitable w
9. above is entered and operated successfully If without any operations the host will automatically hang up and quit after 15 seconds 2 Sending SMS message to control Arm send SMS message XXX XXXBF to control host where XXXXXX is the password Disarm send SMS message XX XXXXCF to control host where XXX XXX is the password The control host will reply message with Arm successfully or disarm successfully Please make sure the SIM card text message storage does not full otherwise this feature may not work 3 Telephone alert receiving After host alerts it will automatically dial all pre set telephones and cellphones in sequence When the user picks up the phone it will immediately broadcast alerting record for 30 seconds and let user obtain the alarming information After phone received if only listen to alerting voice without long distance control please directly hang up the host will continuously dial the latter phone for alerting until someone picks up If there is no person receiving calls the host will dial all phones in circulation for three times then automatically hang up and at the same time it conducts long distance remote control on the alerting host through telephone and cellphone keyboard operation 8 key Enter into the monitoring listening status for 20 seconds If continue to monitor user needs press 8 key again 4 key Play the recorded voice message for one time automatical
10. all surface or in wall corner at a distance of 2 2 4m above the ground Open the sensor shell to connect the batteries well and adjust jumper line short circuit 5S The sensor will detect once every 5 seconds short circuit SMIN The sensor will detect once every 5 minutes suggestion short circuit 5S for testing and SMIN for normal use e Fix the sensor onto the bracket Adjust the sensor to a proper angle and then slide the power switch on the side to ON and it will enter into the normal working state after 30 seconds Upon the working light flashes frequently in blue please replace the batteries Wireless Indoor Siren Features e Work with alarm host wireless receiving alarm signals spot alarming with sound and flash With power plug usually for indoor use Specifications Operating Power 100 240VAC Receiving Distance gt 100 M In open area Installation and Usage Plug the wireless siren into suitable indoor power socket Suggestion Generally around 1 8M from the ground How to reset unregister Plug the indoor siren into the power gt Press down and hold the learning button at the side for 15 seconds and release gt the LED in the siren flashes once Wireless Smoke Alarm Features e Mainly monitor and control indoor fire risks generally set to Emergency Zone Replace the batteries for every or 2 year e Usually installed on the ceilings of living room and Working Light
11. e Panel it insufficient check Panel power whether plugged well frequently in blue specification flashes frequently specification controller gets shorter specification www usmartbuy com
12. e the system on the disarmed status After disarming even triggering detectors can NOT make the control host alert except the detectors in emergency zone or emergency key in the remote control After disarming All alarm and Part alarm LED light die out 5 Emergency alerting When emergency happens press on the emergency key in the remote control keypad or panic button C Host Installation DO NOT INSERT THE SIM CARD INTO THE CONTROL HOST WHILE THE CONTROL HOST IS TURNED ON OR WORKING Make sure the SIM card PIN code has been turned off It is recommended to turn off the voice mail for the SIM card Put on the antenna please do not over tighten the nut Open the SIM card slot at back of the control host Put the SIM card in to the tray and lock the slot The metal contact of the SIM card must be down Connect the power to the host and turn the switch at the side to DC ON Please wait for searching the GSM network for a while If the GSM Signal LED on the host blinking every 5 seconds it means the host has found the GSM signal If the GSM Signal LED on the host blinking every 1 second or stay on it means the host has not found the GSM signal o ES D M please check if the SIM card has been installed properly D Register Program Learn Sensors to the Control Host 1 Register siren to the control host Normally the wireless indoor siren has already been registered with the control host by manufacturer not need to
13. ly key Quits from the status and hang up the system will not dial the next group of numbers 4 SMS message alert receiving Mobile will get SMS message like System Alarming XX YYYY XX means zone number YY YY means the sensor name www usmartbuy com J Alarm Setting Command Before operating the alarm function setting commands in Table below user needs to make sure the control host has entered into the program status How to enter into the program status Make sure the control host is in disarmed status and Press SET gt Programming LED light up if it does not light up please press ESC first and then press SET again gt Input Password default 888888 and press ENT i i Default To be programmed Setting Command Operation Instruction detti etting X Phone number group number can be 1 6 1 for CID protocol 2 for XSJ 0 gt X gt ENT gt protocol 3 6 for personal phone No Telephone number gt ENT numbers number normally just enter 3 6 number gt Y gt ENT Y 0 or 1 O phone call alarm 1 SMS message alarm Exit delay 1 gt X gt ENT X 0 0 second or 1 15 seconds oO Entry delay 2 gt X gt ENT X 0 0 second or 1 15 seconds oO Emergency alarm l 3 gt X gt ENT X 0 silent or 1 audible 1 sound Perimeter zone motion zone alarm 4 gt X gt ENT X
14. ocal Arm Home Arm Disarm Emergency Alarm 1 Arm i By wireless remote control Press the Away button All alarm LED lights up and the control host will beep once to complete the operation successfully ii By keypad on the control host press A Y on the control host keypad to choose Arm All alarm LED will light up 2 Home arm i By wireless remote control Press the Home button Part alarm LED lights up and the control host will beep once to complete the operation successfully ii By keypad on the control host press A Y on the control host keypad to choose Home Arm Part alarm LED will light up 2 Disarm i By wireless remote control press the corresponding disarm button and the host will beep twice to successfully complete the operation www usmartbuy com ii By keypad on the control host Press ESC land enter password gt Press ENT gt the control host will beep twice to successfully complete the operation I Phone long distance control 1 Call in to control Dial the phone number associated to the SIM card which in the control host through telephone or cellphone After a cycle of ringing the control host will pick up the call After one beep enter password default password is 888888 and then after one beep pressing phone or cellphone keys Concrete operation is as follows 1 key Arming 0 key Disarming The control host will automatically hang up after every command
15. one number 11 15 At home armed status sensors in this zone will not trigger the alarm Generally is used for wireless wide angle iii Emergency zone zone number 01 05 All sensors in Emergency zone will trigger the alarm whenever the alarm is armed or disarmed It is used for detecting the space like Emergency area such as emergency distress medical rescue gas leakage and fire alarm etc this zone keeps 24 hour monitoring Generally is used for panic button wireless gas sensors and wireless smoke sensors 2 Arming Arming means that when there are no persons at home and need to all around guarded All detectors are working Once something triggers the detectors the alarm sets off After arming operation All alarm LED on the host will be always on 3 Home arming Home arming means that when there are some body at home for the sake of security it is needed to make the outside doors windows balconies and around detectors of the alerting system work But it is also needed to avoid the person at home from triggering the domestic detectors to alert wrongly At that time we choose home arming letting some detectors work and the other not At home arming status all sensors in motion zone will not trigger the alarm After Home arming operation Part alarm LED on the host will be always on www usmartbuy com 4 Disarming operation Disarming means that when control host sets off it can stop the alerting or mak
16. please press ESC first and then press SET button again gt Input Password default 888888 and press ENT gt Press 7 gt Press 0 gt Press ENT gt Input Zone Number can be zone number between 06 www usmartbuy com and 10 and press LENT gt Learn LED lights up gt use magnet contact to trigger the sensor twice successively gt when hear long Beep from the control host and see the Learn LED flashes and then off this means the sensor learning is successful After that please turn off registered sensor and start from again to register another sensor iii Register PIR to the control host Normally zones 11 to 15 are used for PIR sensor Each zone can learn 4 sensors Open PIR s cover and install the battery gt Make sure the control host is in disarmed status and Press SET gt Programming LED light up if it does not light up please press ESC first and then press SET again gt Input Password default 888888 and press ENT gt Press 7 gt Press 0 gt Press ENT gt Input Zone Number can be zone number between 11 and 15 and press ENT gt Learn LED lights up gt Turn on the switch at the side of the sensor up for ON and down for OFF and press the sending button on the PIR s PCB twice successively gt when hear long Beep from the control host and see the Learn LED flashes and then off this means the sensor learning is successful After that please turn
17. register again i Register wireless indoor siren to the control host Make sure the control host is in disarmed status Turn off all sensors Connect the indoor strobe siren to the power socket and then wait 10 seconds for the initialization Press and hold the Learn button at the side of the indoor siren for about 15 seconds and all lights flash once Press the Learn button at the side of the indoor siren and all lights on Press key on the host and alarm host goes off Press Ce key on the host and input password and press ENT The indoor strobe siren flash for 5 times to indicate the learning is successful www usmartbuy com il Register wireless Outdoor Strobe Siren to the host Make sure the control host is in disarmed status Turn off all sensors Turn off wireless indoor siren Connect the outdoor strobe siren to the power socket and wait 10 seconds for the initialization Press down the green button at the back of outdoor siren Press red button at the back of outdoor siren and all lights on not only power LED Press key on the host and alarm host goes off Press Ce key on the host and input password and press ENT The outdoor strobe siren flash for 5 times to indicate the learning is successful 2 Register sensors to the control host Normally the sensors in the big blue box have been programmed learned to the host For additional sensors please refer to the user manual or sections below for how to p
18. rogram sensors learn sensors to the host Command 7 gt 0 gt ENT gt YY gt ENT Where YY Zone number includes 00 15 It is recommended that to turn off all sensors first and then only turn on the sensor which needs to be learned After each successful learning please turn off the learned sensor and turn on the next sensor which needs to be learned i Register remote control to the control host Use zone 00 for remote control and it can learn up to 10 remote controls Make sure the control host is in disarmed status and Press SET gt Programming LED light up if it does not light up please press ESC first and then press SET again gt Input Password default 888888 and press KENT gt Press 7 gt Press 0 gt Press ENT gt Input 00 and press ENT gt Learn LED lights up gt Press the button on the remote twice successively gt when hear long Beep from the control host and see the Learn LED flashes and then off this means the sensor learning is successful After that please start from again to register another sensor il Register door window gap sensor to the control host Normally zones 06 to 10 are used for door window gap sensor Each zone can learn 4 sensors Open the cover at the side of the sensor and put in a battery gt Make sure the control host is in disarmed status and Press SET gt Programming LED light up if it does not light up
19. ss remote amp Wireless Keypad 10 remote controls Wireless Wireless Smoke Alarm 01 05 Emergency zone Bach zone sensors Wireless Gas Alarm amp Panic button etc Wireless Door Window Sensor amp supports upto 4 06 10 Perimeter zone wireless Wireless Curtain PIR etc sensors 11 15 Wireless Wide Angle PIR Motion Sensor etc Note Default set by manufacture in the big blue box Wireless Wireless door Wireless wide angle PIR Wireless gas Wireless smoke Wireless sensor remote sensor sensor sensor sensor EES RN CAT ff ef N Understanding of Wireless Sensor and Installation Wireless Remote Control Away Features I To control the alarm host to arm and disarm Disarm e With the emergency key for urgent help I un Specifications WI Emergency Operating power 27A 12V alkaline battery e Emitting distance gt 100m in open area Service life lt 1 year www usmartbuy com Installation and Usage For users to take along Generally press the Away key to arm before leaving home and press the Disarm key to disarm 29 66 Home is for Home Arming Home Arming is only effective for sensors in Perimeter Zone Wireless Door Sensor Features Generally set as Perimeter zone O If any door or window is opened it will transmit the alarm signals to o the alarm host Specifications Operating power 23A 12
20. trol Host Command 0 gt X gt ENT gt Telephone number gt ENT gt Y gt ENT Where X Phone number group number can be 1 6 Y 0 or 1 0 phone call alert 1 SMS message alert You can store 6 phone numbers Group 1 and 2 are for monitoring centres and other 4 groups are for personal numbers In this case group 3 6 are used here Make sure the control host is in disarmed status and Press SET gt Programming LED light up if it does not light up please press ESC first and then press SET again gt Input Password default 888888 and press KENT gt Press 0 gt Input group number can be 3 to 6 and press ENT Enter telephone number and press ENT gt Enter 0 call alert it will dial the preset phone number OR Enter 1 for SMS message alert it will send SMS message gt Press ENT G Voice Message Recording Make sure the control host is in disarmed status 2 Check if the power adapter has been connected to the control host the voice message recording only works when the control host is connected to the external power Turn the switch at the side of the host to Record On Press and hold key and speak close to the host then release the key to stop recording Turn the switch at the side of the host to DC On press and hold the key to playback the recorded message Nn nA AB W After the successful recording please turn the switch at the side to DC ON H L