Home
SNMP user manual for SR...L
Contents
1. Login with the mouse Note that in some browsers pushing the Enter key to log in may not work MONITORING amp CONTROL Network Settings PSU Configuration SNMP Configuration Syslog Configuration Firmware Upgrade Contact Details energies Power Supply Status Good DC Battery Status Output Voltage 13 7 PSU Current 0 0 Temperature Log Low 2 Temperature Log High THRESHOLDS Please note that only integer values are accepted Temperature High Threshold degC Temperature Low Threshold degC Over Voltage Threshold V Psu Current Threshold A 3 1 CONTROL Reset Temperature Log Resets the temperature log 3 2 MONITORING Power Supply Status Good Input voltage mains present Mains failure No input voltage DC Battery Status Normal DC output gt V low Low DC voltage at output lt Vlow PSU or battery if connected Output Voltage DC voltage at output PSU or battery if connected PSU Current Current supplied by PSU Temperature Temperature reading is taken from the temperature sensor which is normally placed near the batteries If no temperature sensor is fitted the displayed value is N A Temperature Log Low Displays the lowest temperature recorded Temperature Log High Displays the highest temperature recorded 3 3 THRESHOLDS Threshold values can be set by the user according to their re
2. INNOVATIVE ENERGIES CONTACT DETAILS At Innovative Energies we pride ourselves on being able to provide the best service to all of our customers Our technical staff are always prepared to work with you to design repair or solve any software related issues that may arise We are located at 1 Heremai Street Henderson Auckland NZ Free phone 0800 654 668 Phone 64 9 835 0700 Website www innovative co nz Email info innovative co nz 14
3. 10 z energies Power Supply SNMP Interface User Manual for SR L versions RS232 SNMP L User Manual 150722 firmware 02r_a12 doc Table of Contents Ts INTRODUCTION 0 ass al dde uti da a ae eaaa eaaa debi oae aiaa 3 A A AN 3 25 LOGIN conatascrrsesdu saldar etilo rieles 4 3 MONITORING CONTROLE nitrato lada ene iia 5 dl CONTROL 20 AS A AN ERE 6 3 2 MONITORING cenae a e E E E EERE E E 6 3 3 THRESHOLDS ii eee eas elie a AEA aA AEEA 6 4 s NETWORK SET TINGS 00 ira in IA Senet 7 4 1 Disabling DHCP allocating a static IP AUUTesSS oooonoonocccoccocccccccnccnnccnccconocnnncnnannonnonnnnnnnnnnnnnnos 7 4 2 Enabling DHCP a olaa nodos 8 4 3 Changing Static IP from one to ANOthel cceeseccecceeceeeceeeeeeeeeeeeeeeeteeceeseeeeenseccaeeaeeeeeeeeeees 8 D PSU CONRIGURATION ances Meets Peach A a Dee dt a Seeds tad ig dee soles nas 9 5 1 Understanding PSU Configuration TerMS ooooocccncccnccncccnccncnncnnnnnnnnnnononnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnns 9 6 SNMP CONFIGURATI N cocina ii didas 10 6 1 Understanding SNMP Configuration Terms ooooccccccccccccccccccnncnnnonnnnnnonnnnnnonnonnnnnnnnnnnnnnnnnnin 11 Ta SYSLOG CONFIGURATION str AA ea lta ee 12 7 1 Understanding Syslog Configuration Terms ooooocccccnccccccnccinncnnnonnnnnannno nono nnnnnnnnnnnnnnnnnnnnnin 12 8 FIRMWARE UPGRADE PASSWORD CHANGE vs isticicitaidta cia dintel edit 13 8 1 Change Password atrio end diarias 13 9 INNOVATIVE ENERGIES C
4. MP Trap Read Write Community System Contact System Name System Description System Location Trap Destination IP SNMP Trap Port SNMP Agent Port An alert message that the user can enable or disable Identifies groups and their set permission rights The default setting for this is iepublic This is user specified and able to display names phone numbers or email addresses This area is user specified This area is user specified This area is user specified Identifies where the alert message is to be sent The user specifies the IP Address of the PC they want the SNMP traps alerts sent to Displays the port number of the SNMP trap default is 162 Displays the port number of the SNMP agent default is 161 11 7 SYSLOG CONFIGURATION The Syslog is used for recording SNMP syslog messages SYSLOG Configuration SR100L12T Monitoring amp Control SYSLOG DISABLED gt Network Settings SYSLOG Server IP 2 PSU Configuration SYSLOG Port a SNMP Configuration SYSLOG Update Firmware Upgrade Contact Details 7 1 Understanding Syslog Configuration Terms Syslog The syslog can be enabled or disabled Syslog Server IP This displays the user specified IP address that is used for monitoring the Syslog data Syslog Port This displays the port number of the PC setup to monitor the Syslog default is 514 SYSLOG Update This function refreshes all of the user specified da
5. ONTACT DETAILS vscoconact tii 14 1 INTRODUCTION Innovative Energies Ethernet enabled DC power supplies and No Break DC UPS can be accessed via a network connection to provide accurate information for the monitoring of critical power systems These models will have the suffix LAN in the model code This user manual refers to units using SNMP protocol 1 1 Default IP Address Unless specified otherwise at the time of ordering we set a static IP address of 192 168 2 10 The built in web server may also be set to DHCP enabled in which case the network it is connected to will need to have a DHCP server to allocate an ip address to the unit Refer to http www snmp co nz for further information You will need to use some proprietary software eg Radmin http www advanced ip scanner com to find the IP address allocated to the device Using a web browser eg Internet Explorer Firefox Chrome type the IP address into the url address box of the web browser eg 192 168 2 10 The following screen will appear mhovative energies Series_L Login Screen System Location Password Login All pages on this site 2011 Innovative Energies 2 LOGIN The default password is iepassW1 Note that the password is case sensitive Insert the default password into the Password box Note The System Location field can be changed personalised on the SNMP Configuration web page see page 14 Click on
6. default code for the alarm trap mask is set at 1048187 A new code may be calculated by using the excel spreadsheet available at http www innovative co nz service SNMP by clicking on ALARM MASK CALCULATOR Simply insert 1 into the required yellow column to enable a trap or insert 0 into the required yellow column to disable a trap MIB files are available by going to www innovative co nz and clicking on Communication Enabled DC on the side menu bar Alarm traps may be resent if a fault continues to persist The resent time can be set by modifying the SNMP variable TrapPeriodicResentTimeinMinutes The resent time range for resending traps is between 30minutes and 10079 minutes 7 days If the user sets the range outside of these parameters it will default to 1440 24hours which is also the factory default for a new device Note The new settings only take effect after performing a software reboot of the power supply web server SNMP Configuration SRIOOLi2T Monitoring amp Control SNMP Wap ENABLED y Network Settings Read Write Community fiepublic PSU Configuration System Contact SS System Name Sm PSU Syslog Configuration Firmware Upgrade System Description Innovative Contact Details System Location Trap Destination IP 1921682 99 SNMP Trap Port 162 SNMP Agent Port 161 SNMP Update 10 6 1 Understanding SNMP Configuration Terms SN
7. om one to another To change the IP if your device has a static IP address a Type in the desired IP address eg 192 168 100 53 b Delete the gateway address 255 255 255 255 and leave it blank c Click on the Submit button 5 PSU CONFIGURATION This page displays the parameters programmed into the firmware of the power supply These parameters are programmed in the factory and are not able to be changed by the user energies PSU Configuration SR100L12T VLow 11 0 VHigh 14 3 Serial Number 0026 2006 Monitoring amp Control Network Settings PSU Configuration SNMP Configuration PSU Version IEL NB5sys V13 Syslog Configuration gt Firmware Upgrade Contact Details All pages on this site 2011 Innovative Energies 5 1 Understanding PSU Configuration Terms VLow Voltage at which a DC Low alarm signal and SNMP trap are generated VHigh Voltage at which a DC High alarm signal and SNMP trap are generated Serial Number Serial Number of the power supply PSU version Power supply revision version number 6 SNMP CONFIGURATION All fields are customisable and may be specified by the user to suit their specific applications SNMP traps alerts can be monitored using a SNMP manager of the user s choice The user may select which traps are set by changing the alarm trap mask code which is accessed by using a MIB Browser such as iReasoning MIB Browser The
8. quirements SNMP trap alert messages will be sent when one of the thresholds are exceeded The units for the threshold fields are Temperature High Low degrees C Over Voltage Volts PSU Current Amps 4 NETWORK SETTINGS This page enables the user to set a static IP address eg 192 168 2 10 or enable DHCP function imhovatiye energies Network Settings SR100L12T MAC Address 00 20 4a e0 99 7d Monitoring amp Control Network Settings DHCP Client Enable PSU Configuration SNMP Configuration IP Address 192 168 101 123 DHCP Syslog Configuration Network Mask 255 255 255 0 DHCP Firmware Upgrade po Gateway Na DHCP Contact Details Submit Note Remove DHCP from ip addresses text box before disabling dhcp All pages on this site 2011 Innovative Energies 4 1 Disabling DHCP allocating a static IP address To disable DHCP follow the steps below a Set DHCP Client to Disable b Type in the desired IP address eg 192 168 2 10 this is the ex factory default unless otherwise specified at time of order c Remove DHCP and all preceding spaces from the Network Mask field d Leave the Gateway field blank d Click on the Submit button 4 2 Enabling DHCP To enable DHCP if your device has a static IP address a Set DHCP Client to Enable b Leave all other fields blank c Click on the Submit button 4 3 Changing Static IP fr
9. ta above 12 8 FIRMWARE UPGRADE amp PASSWORD CHANGE Firmware Upgrade SR250L24T Current LAN firmware version ie_x2p_02r_a12 Monitoring amp Control gt Network Settings Enter LAN firmware filename PSU Configuration firmware img SNMP Configuration Upgrade and Reboot Syslog Configuration Change Password Contact Details New Password eoecccce New Password Confirm eeccccce This page is used to update the software to the latest version This is done by using a standard FTP programme such as the Filezilla Client available at www filezilla project org For detailed instructions on how to do this using Filezilla go to http innovative co nz uploads Filezilla 20instructions pdf Default settings are User Name root Password iepassW 1 The upgrade file is always named firmware img and needs to be transferred to the mnt flash folder in the web server built into the power supply Notes 1 After completing the firmware upgrade the power supply will automatically reboot and you will need to log in again 2 As at 22 July 2015 the current firmware version is 02r_a12 8 1 Change Password The default password is iepassW1 and may be updated by the user Please note that there is no facility to reset a lost or forgotten password as this would defeat the purpose of a password and the unit will have to be returned to the factory for reprogramming 13 9
Download Pdf Manuals
Related Search
Related Contents
取扱説明書ダウンロード(PDF) - Bearmax|株式会社クマザキエイム A N R E T NI E D A DI N U TP17 Philips RFX9200 Network Extender ETIQUETAGE DES DENREES ALIMENTAIRES HiQnet third party programmers guide v2 _3 Parani-MSP100 User Guide Netgear WNAP210 Data Sheet TFConnect User Manual - Installation Package for TFConnect PlaneBook Owners Manual Copyright © All rights reserved.