Home
16x16 DVI Matrix w/ Push Button Control
Contents
1. 51 16 RS 232 TELNET UDP COMMANDS Command fadefault help lock_fo set_input_name set_ir set_output_name show_temp show_user_name show_ver_data show_voltage Miscellaneous Resets the matrix to factory default routing Displays all available commands Toggles the 5V lock power state Specifies a name for an input Sets the IR channel of the matrix Specifies a name for an output Displays the board temperatures Displays the TCP user name Displays the current hardware Displays the board voltages Toggles displays 5V input Displays the current routing status in tabular form fadefault Command The fadefault command disables the EDID lock state sets the default routing state 1 1 2 2 3 3 etc and resets the input and output names to the default names e g Output 1 Input 1 Syntax fadefault Parameters None 52 RS 232 TELNET UDP COMMANDS help Command The help command displays help on the specified command If param7 is not specified then the full list of commands is displayed Syntax help paraml Parameters param1 Command name Example help callpreset Cmd callpreset Recall a routing and mask state preset Syntax callpreset paraml Paraml 1 16 preset e g callpreset 2 lock_fo Command The lock_fo enables disables the power lock state Enabling this feature will store the 5V status for each input prior to shutting down the ma
2. Li LA ROUTING MODE 4 Select the desired input source button 1 16 For this example we want to route the source connected to Input 6 to each of the outputs in step 3 Therefore press button 6 on the bottom row The selected input will glow bright blue NOTE Only one input can be routed at a time If the wrong input button is accidentally pressed then continue by pressing the correct input button The previous input button will automatically be deselected 13 ROUTING r LH TBE L ROUTING MODE ee Ei PRO 5 Press the Set button on the front panel again to complete the routing operation The front panel display will indicate that the routing process has been completed 6 After a few moments the selected buttons on the front panel will turn off and the matrix will return to the standby screen GEFEH 16416 IWI MATRIX Getting the Current Routing Status of an Input To display the current routing status of an input press the desired input button on the front panel of the matrix Once the input button is pressed the routed outputs will be displayed From our previous routing example we already know that Input 6 is routed to Output 3 6 7 and 9 Let s use this to illustrate how to retrieve the current routing status of an input continued on next page 14 ROUTING 1 Press the button for Input 6 on the matrix 2 The current routing status for Input 6 will be display
3. SOP Rr PROGRESSIVE ona visual interface 16x16 DVI Matrix w Push Button Control GEF DVI 16416 PB User Manual www gefenpro com ASKING FOR ASSISTANCE Technical Support Telephone 818 772 9100 800 545 6900 Fax 818 772 9120 Technical Support Hours 8 00 AM 5 00 PM Monday through Friday Pacific Time For 24 7 support see the front panel of the product for the support number Write To Gefen LLC c o Customer Service 20600 Nordhoff St Chatsworth CA 91311 www gefenpro com support gefenpro com Notice Gefen LLC reserves the right to make changes in the hardware packaging and any accompanying documentation without prior written notice 16x16 DVI Matrix w Push Button Control is a trademark of Gefen LLC 2015 Gefen LLC All rights reserved All trademarks are the property of their respective owners Rev A11 GO l O Qn E G KM CONTENTS Introduction Operation Notes Features Front Panel Layout Front Panel Descriptions Back Panel Layout Back Panel Descriptions IR Remote Description IR Remote Installation IR Code Configuration Connecting And Operating The 16x16 DVI Matrix w Push Button Control Wiring Diagram Front Panel Display Routing Routing Inputs to Outputs Getting the Current Routing Status of an Input Getting the Current Routing Status of an Output One to One Routing Presets Saving the Current Routing State Recalling a Saved Routing State Masking Masking Outpu
4. 4 Press the Set button The Set button will flash momentarily Set button EDID DSTOLO MODE 5 Once the Set button is pressed the matrix will begin copying the downstream EDID from the display or other sink to the EDID from the selected output to the specified input The front panel display will indicate that the matrix is copying the EDID 6 After the EDID has been successfully copied to the selected input the front panel display will show the following message 27 EDID MANAGEMENT Saving the Default EDID to an Input There may be instances when the downstream EDID data is corrupt or the EDID is not be ing read correctly by the matrix On the other hand it may be desirable to use a generic EDID as opposed to the downstream EDID In any case the matrix provides a default internal EDID that can be used Let s look at an example 1 Press the EDID button twice The EDID button will glow bright blue and the front panel display will indicate that the matrix is ready to copy the default EDID to the specified input EDID DETOLO MODE DETOLO is an abbreviation for DEfault TO LOcal 2 Select the input where the default EDID will be copied For this example we will copy the default EDID to Input 5 Therefore we will press the button for Input 5 ENFNHNEHEHHEHHHHBHHHHBHEHHHEEB EDID DETOLO MODE EEE BEERS EERE EEE ee Ei PRO continued on next page 28 EDID MANAGEMENT 3 Pre
5. Active enabled Click the Active button again to toggle the masking state to Mask disabled 70 WEB INTERFACE IP Configuration IP Settings Assigns IP address subnet gateway HTTP listening port and Telnet port Note that the MAC address can not be changed Click the Save button to apply changes The matrix must be rebooted for the changes to take effect e CCS 16x16 DVI Manager VIEW MATRIX STATUS MANAGE EDID MASKING IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT IP Settings MAC Address 00 1C 91 01 01 B2 IP Address 192 168 1 239 Subnet 255 255 255 0 Gateway 192 168 1 1 HTTP Pot 80 TCP Port 23 UDP Port 8 TCP connection Login Settings User Name Administrator Old Password 66666 New Password Confirm New Password Force Password E UDP Con wwa lP Settings MAC Address 00 10 31 01 01 B2 IP Address 192 166 1 239 Gateway 192 168 1 1 HTTP Port BU TCP Port 23 UDP Port 8 Save TCP connection Login Settings User Name Administrator Old Password TILL New Fassword Confirm New Password Force Password E Telnet Login Settings Sets the user name and password for Telnet sessions to the matrix Click the Save button to apply changes 71 WEB INTERFACE GES 16x16 DVI Manager VIEW MATRIX STATUS MANAGE EDID MASKING IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT IP Settings MAC Address 00 1C 91 01 01 B2
6. return to the standby screen L Eg E Lj LJ E E F L C E Li W L Lj LJ L E GEFEH 16x16 IVI MATRIX 22 NODE BUTTONS Unmasking Outputs Once an output or multiple outputs has been masked it can be unmasked Unmasking an output will allow the video signal to be displayed after a masking operation We ll continue with our previous example and unmask Output 5 and Output 6 1 Press the Mask button The Mask button will glow bright blue and the front panel display will indicate that the matrix is in mask mode Once the mask button is pressed any outputs that have been masked will be indicated on the front panel Mask MODE 2 Press the desired output button s to unmask the output In our case we will select both Output 5 and Output 6 Each button will turn off as it is pressed SH PRO MASK MODE 3 Press the Set button The Set button will flash momentarily Set button MASK MODE BRT 8888888888888888 23 NODE BUTTONS 4 Once the Set button is pressed the front panel display will indicate that the unmasking process was successful 5 After a few moments the matrix will return to the standby screen BEFEH 16x16 IVI MATRIX 24 LOCKING THE MATRIX Locking the matrix will prevent any changes by disabling all buttons except the Lock button on the front panel This feature is useful in preventing routing or other changes caused by accidentally pressing the buttons on the front pan
7. Description 16x16 DVI Matrix Web GUI Web Page Reboot Show Me If desired the Description field can be changed as well This is useful to identify if you have multiple units running on a network Click the Save button at the bottom right corner of the screen Click the Reboot button Click the Web GUI link above the Reboot button to access the built in web interface The following table lists the default IP settings for this product Description Address Port Address Port IP Address 32 RS 232 TELNET UDP COMMANDS EDID Management dynamic_edid Command The dynamic_edid command provides the ability to route any downstream EDID to any input When enabled the EDID is copied to all inputs from the last selected active output When disabled the EDID is copied to all inputs from the first active display detected starting from Output 1 Syntax dynamic edid parami Parameters param1 Value 0 1 are menin o Disable Default Disabled 33 RS 232 TELNET UDP COMMANDS edidbatolo Command The edidbatolo command reads the downstream EDID and stores it to any local input Syntax edidbatolo paraml param2 param3 param9 Parameters param1 EDID bank offset 1251 param2 Input 1 16 Notes If param2 0 then the EDID in the specified bank is copied to all eight inputs ediddetolo Command The ediddetolo command stores the Default EDID 640x480 in the
8. Displays GEF DVI 16416 PB ATTENTION This product should always be connected to a grounded electrical socket 11 FRONT PANEL DISPLAY Main Display The Main Display of the 16x16 DVI Matrix w Push Button Control is a 16 character 2 line display This display will show the Standby Screen and will also be used to aid in performing routing commands When the unit is powered on the following screen is displayed After a few moments the standby screen is displayed The standby screen is shown below Displaying Additional Information Pressing the Cancel button consecutively will cycle through other screens such as firmware version and boot loader version 12 ROUTING Routing Inputs to Outputs The following example illustrates the routing process An input may be routed to a single or multiple outputs Multiple inputs cannot be routed to a single output For this example we will route Input 6 to the following outputs Output 3 Output 6 Output 7 and Output 9 1 Press the Set button on the front panel Pressing the Set button tells the matrix that we want to perform a routing masking or preset operation The Set button will glow bright blue indicating that it has been pressed ROUTING MODE erie PRO 2 The front panel display will indicate that routing mode is active 3 First we need to specify the outputs Press buttons 3 6 7 and 9 The selected buttons will glow bright blue
9. MODE BEERS BERR REE EEE LE GT PRO 2 Select the desired outputs to be masked In this example we will select Output 5 and Output 6 Each output button will glow bright blue as they are pressed EEE BEERS MASE MODE BEERS BREE REE EERE ES erie PRO 3 Press the Set button to mask the selected outputs The Set button will flash momentarily Set button BEMEBE ESSER EERE REG x MASE MODE cETERIPRO continued on next page 20 MASKING 4 Once the Set button is pressed the front panel display will indicate that the masking process was successful 5 After afew moments the selected buttons will turn off and the front panel display will return to the status screen GEFEH 16x16 DVI MATRIX 21 MASKING Getting the Current Masking Status If the masking state is unknown it can be queried using the Mask button Alternatively the masking state can be retrieved through the Web Interface or by using the m command 1 Press the Mask button The Mask button will glow bright blue and the front panel display will indicate that the matrix is in mask mode If any outputs are currently masked they will be indicated on the front panel For example since we recently masked Output 5 and Output 6 these buttons will glow bright blue as shown below EER EERE ERE EEE MASK MODE EES BERR ERE EEE EERE ES 2 After afew moments the selected buttons will turn off and the front panel display will
10. Secure Local EDID function using RS 232 or IP control There is no internal scaling in the 16x16 DVI Matrix w Push Button Control Each monitor attached to the Matrix must be able to display the resolutions output by the source device s For maximum compatibility it is recommended that only one common resolution be used by each source device Advanced EDID features and IP configuration features are accessible through the RS 232 serial command set Routing and EDID features can be managed using the built in IP control feature This matrix supports Dynamic EDID See page 61 for details The Gefen Syner G Software Suite is a free downloadable application from Gefen that provides automatic download and installation of firmware upgrades for this product Download the application here http www gefen com synerg The Gefen Matrix Switcher Keyboard Controller is a free downloadable application from Gefen that allows a computer keyboard to be used to switch between sources This application uses the Telnet protocol to control any Gefen switcher or matrix that uses IP control Download the application here http www gefen com support download jsp i IMPORTANT If the unit is installed in a closed or multi rack assembly do not block the ventilation holes of the enclosure FEATURES Features Supports resolutions up to 1920 x 1200 Front panel push buttons for local switching e Front panel LCD Display Switching is co
11. This Matrix provides a simple reliable and highly effective method of streamlining any installation using multiple sources and outputs taking the hassle out of managing multiple connections Each DVI source is accessible at all times by any monitor using the front panel buttons IR remote unit built in RS 232 or using IP control How It Works Connect 16 sources to the DVI input ports on the Matrix using the supplied DVI cables Connect 16 monitors to the Matrix Power on the source devices and the monitors Plug in the power cord and power on the Matrix Use the push buttons on the front panel for routing each DVI source to the desired display The connected monitors will display video according to the routing state NOTE This Matrix only supports DVI D The DVI connectors on the Matrix all have 29 pins OPERATION NOTES READ THESE NOTES BEFORE INSTALLING OR OPERATING THE GEFENPRO 16X16 DVI MATRIX W FRONT PANEL PUSH BUTTON CONTROL The 16x16 DVI Matrix w Push Button Control does not support HDCP content Make sure that a DVI monitor is powered and connected to one of the DVI outputs on the 16x16 DVI Matrix w Push Button Control before applying power By default the Local EDID is read from the connected monitor and is copied to all 16 DVI inputs once the Matrix has been turned on If a monitor is not detected by the Matrix at power on a default internal EDID of 640x480 will be used This functionality can be disabled using the
12. matrix Sets the IP network mask Enables disables password prompt for TCP sessions Enables disables UDP listening 38 RS 232 TELNET UDP COMMANDS ipconfig Command The ipconfig command displays all TCP IP settings on the matrix Syntax ipconfig Parameters None Example ipconfig MAC add 00 1C 91 01 01 01 IP add 19216851472 Net Mask 255 255 255 0 192 168 1 254 Gateway Web Server Port 80 TCP Terminal Server Port 23 TCP Terminal password at login is set to ON UDP Server Port 25665 UDP Remote IP 110 0 255 255 UDP Remote Port 26989 UDP Access Disabled resetip Command The resetip command resets all TCP IP settings to factory defaults Syntax resetip Parameters None Notes The matrix must be rebooted after executing this command 39 RS 232 TELNET UDP COMMANDS set_http_port Command The Zset http port command sets the Web server listening port The default port is 80 syntax set http port paraml Parameters param 1 Port 0 65535 Notes The matrix must be rebooted after executing this command set_tcp_term_pass Command The set_tcp_term_pass command sets the TCP password The maximum length of the password is 20 characters and is case sensitive The default password is Admin Syntax set tcp term pass paraml Parameters param1 Current password param2 New password param3 New password confirm Notes The m
13. specified Local EDID inputs Syntax ediddetolo paraml param2 param3 param9 Parameters param1 Input 1 16 Notes If param1 0 then all 16 DVI inputs will be set to the Default EDID 34 RS 232 TELNET UDP COMMANDS ediddstoba Command The ededdstoba command reads the downstream EDID and stores it to a specified EDID bank Syntax ediddstoba paraml param2 Parameters param1 A downstream monitor 1 16 param2 EDID bank offset KETT ediddstolo Command The ediddstolo command reads the downstream EDID and stores it to a Local EDID input Syntax ediddstolo paraml param2 param3 param9 Parameters param1 A downstream monitor 1 16 param2 Input list 1 16 Notes If param2 0 then the downstream EDID is stored to all 16 DVI inputs If more than eight inputs need to be specified in order to receive the downstream EDID the ediddstolo command must be executed twice Example ediddstolo 212345678 9 10 11 not permitted Instead run the function twice ediddstolo 21234567 8 ediddstolo 2 9 10 11 35 RS 232 TELNET UDP COMMANDS lock_edid Command The lock_edid command secures the Local EDID and disables the automatic loading of the downstream EDID after the matrix is powered on This feature can also be controlled using the Web Interface see page 69 Syntax lock edid paraml Parameters param1 Input 0 1 o Disable prbaedid Co
14. term pass Command The use_tcp term pass command enables disables the password prompt at the beginning of a session The default setting is disabled This feature can also be enabled or disabled through the Web GUI see page 71 Syntax tuse tcp term pass paraml Parameters param1 State 0 1 LEN Disable password Enable force password Example tuse tcp term pass 1 TCP Terminal password at login is set to ON 45 RS 232 TELNET UDP COMMANDS use_udp access Command The use udp access command enables disables UDP listening Syntax tuse udp access parami Parameters param1 State 0 1 l0 Disable password Enable force password Example use udp access 1 UDP access is set to ON 46 RS 232 TELNET UDP COMMANDS Routing callpreset Recalls a routing mask preset prpreset Displays the preset table savepreset Saves the current routing masking state to a preset r Routes the specified inputs to the specified outputs Routes the specified input to all outputs callpreset Command The callpreset command recalls a routing preset Any masked outputs will also be re called Syntax callpreset paraml Parameters param1 Preset 1 16 prpreset Command The prpreset command displays the preset table Syntax prpreset Parameters None 47 RS 232 TELNET UDP COMMANDS Example prpreset PreSet Outl 2 3 4 5 6 7
15. this button from the Manage EDID screen to access this menu system wask IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT Set Inputto Default EDID Upload EDID J DownloSd EDID Copy EDID EDID Lock State EDID Status Lock State OFF input 6 Default GEFEN XPT DL Select EDID to Download O Output_1 O Output 2 O Output 3 O Output 7 O Output 8 Output 12 Output 13 Download EDID File to PC Select the radio button next to the output containing the EDID to be downloaded Click the Download EDID File to PC button to confirm the change The downloaded EDID file will be in bin format 67 WEB INTERFACE Copy EDID Copy EDID Press this button from the Manage EDID screen to access this menu system GED 16x16 DVI Manager VIEW MATRIX STATUS MANAGE EDID MASKING IP CONFIGUR Select Source to Copy from Output s O Output 1 O Output 6 Output 11 Output 16 Select Source to Copy from Output s O Output_1 O Qutput 2 Output 3 s 2 Output 6 C Output 7 Output 8 E C Output_11 Qutput 12 D Output 13 L Output_16 a abe Input 1 D Input 2 2 Input_3 Input_ O Input_6 2Input 7 D Input 8 O Input Input 11 Input 12 D Input_13 O Input Input_16 Select Input s to Copy to Input 1 lInput 2 Input 3 L Input Input 6 Input 7 IInput 8 _ Input In
16. 16 48 RS 232 TELNET UDP COMMANDS r Command The r command routes the specified input to the specified outputs Syntax r paraml param2 paraml7 Parameters param1 Input 155716 param2 Outputs 1 16 Notes If param2 0 then the specified input is routed to all outputs Examples pr 7 34 5 6 10 12 Input 7 is routed to outputs 3 4 5 6 10 12 r 2 0 All outputs are routed to Input 2 s Command The s command routes the specified input to all outputs Syntax S parami Parameters param1 Input 1 16 Example s 1 All outputs are routed to Input 1 49 RS 232 TELNET UDP COMMANDS Masking Masks the selected video output s Unmasks the selected output s maskout Command The maskout command allows blanking of the specified outputs Syntax maskout paraml param2 Parameters param 1 Output ere param2 State 0 Notes If param1 0 then all outputs will be masked The current masking state will be lost if power is interrupted or if the masking state is not saved see savepreset on page 48 50 RS 232 TELNET UDP COMMANDS unmaskout Command The unmaskout command unmasks the specified outputs Syntax unmaskout paraml param8 Parameters param 1 Output I sss Notes If param1 0 then all outputs will be unmasked Examples unmaskout 3 8 10 Activate outputs 3 8 10 unmaskout O0 Activate all outputs
17. 8 9 10 11 12 13 14 151 16 1 M O M O M O M OIM O M O M O M O M O M O M O M O M O M O M OIM O 2 M O M O M O M OIM O M O M O M O M O M O M O M O M O M O M O M O 3 IM O M O M O M OIM OIM OIM O M O M O M O M O M O M O M O M OIM O 4 IM O M O M O M OIM OIM OIM O M O M O M O M O M O M O M O M O M O 9 IM O M O M O M OIM OIM O M O M O M O M O M O M O M O M OJM O M O 6 IM O M O M O M OIM OIM O M O M O M O M O M O M O M O M O M O M O 7 IM O M O M O M OIM O M O M O M O M O M O M O M O M O M O M OIM O 8 IM O M O M O M OIM OIM O M O M O M O M O M O M O M O M OJM OIM O 9 M O M O M O M OIM OIM O M O M O M O M O M O M O M O M O M O M O 10 IM O M O M O M O M OIM O M O M O M O M O M O M O M O M O M OIM O 11 IM O M O M O M O M OIM O M O M O M O M O M O M O M O M O M O M O 12 M O M O M O M OIM OIM O M O M O M O M O M O M O M O M O M O M O 13 M O M O M O M O M O M O M O M O M O M O M O M O M O M O M O M O 14 IM O M O M O M OIM OIM OIM O M O M O M O M O M O M O M O M OJM O 15 IM O M O M O M OIM O M O M O M O M O M O M O M O M O M O M OIM O 16 M O M O M O M O M O M O M O M O M O M O M O M O M O M OJM O M O savepreset Command The savepreset command saves the current routing state to the specified preset Any masked outputs will also be saved as part of the current routing state Syntax Savepreset paraml Parameters param1 Preset 1
18. HEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE 80 6 PBx 64 1 MA GEF DVI 1 Rev A11 20600 Nordhoff St Chatsworth CA 91311 1 800 545 6900 818 772 9100 fax 818 772 9120 www gefenpro com support gefenpro com ge Oo 3 cc ee
19. IP Address 192 168 1239 Subnet 255 255 255 0 Gateway 192 168 1 1 HTTP Port 80 TCP Port 23 UDP Port 8 TCP connection Login Settings User Name Administrator Old Password III New Password Confirm New Password Force Password 7 UDP Connection Settings UDP remote IP 192 168 1 20 UDP Remote Port 4096 Enable UDP access 7 Reset IP Configuration to Defaults UDP Connection Settings UDP remote IP 192 168 1 20 UDP Remote Port 4096 Enable UDP access Save Reset IP Configuration to Defaults UDP Connection Settings Sets UDP remote IP and remote port Also enables or disables UDP access to the matrix Click the Save button to apply changes Reset Click the Reset button to restore the factory default IP settings 72 WEB INTERFACE Backup Restore The Backup Restore feature for the 16x16 DVI Matrix w Push Button Control is not currently implemented and will be available in a future release of the firmware This feature will be implemented in a future release 73 WEB INTERFACE Power Management Power Status Enabling this feature will store the 5V status for that input prior to shutting down the matrix This preserves the 5V state when the unit is restarted GED 16x16 DVI Manager VIEW MATRIX STATUS MA Power Status Lock State OFF STE oes Die oe See e ac Lower mw HT Warning Use cau
20. Suite Download the application here http www gefen com synerg 2 Connect an Ethernet cable from the network to the IP control port on the product 3 Launch the Gefen Syner G Software Suite 4 Click the GEF DVI 16416 PB from the product list Select Function Discover and Configure IP Manage a Product EDID Editor 00 1D 09 7E E1 1F Local Area Connectic v IP Address MAC Address Description EXT CU LAN 10 5 64 138 00 1C 91 04 60 75 EXT CU LAN RD MASTER EXT HDKVM LAN S 10 5 64 67 02 1D 00 5A 8D 53 EXT DVIKVM LAN L S EXT CU LAN 10 5 64 146 00 1C 91 04 60 17 Dev CU FAN Nick Desk EXT CU LAN 10 5 64 130 00 1C 91 04 60 5D EXT CU LAN RDSLAVE GEF DVI 16416 PB 192 168 1 72 00 1C 91 04 80 14 16x16 DVI Matrix Device Settings Product Name GEF DVI 16416 PB IP Mode Static MAC Address 00 1C 91 04 80 14 Web GUI Port 80 IP Address 192 168 1 72 Telnet Port 23 Subnet Mask 255 255 255 0 Firmware Version v1 0 Gateway IP 192 168 1 1 Hardware Version v1 0 DNS Description 16x16 DVI Matrix 31 D RS 232 IP CONTROL Under the Device Settings section enter the desired IP address subnet mask gateway IP address Web GUI port and Telnet port in the supplied fields Device Settings Product Name GEF DVI 16416 PB IP Mode Static MAC Address 00 1C 91 04 80 14 Web GUI Port 80 IP Address 10 5 64 254 Telnet Port 23 Subnet Mask 255 255 255 0 Firmware Version v2 1 9 Gateway IP 10 5 64 1 Hardware Version v2 0
21. acters Syntax set output name paraml param2 Parameters param1 Output 1 16 param2 Name Example set output name 3 display 3 display 3 is assigned to output 3 show_temp Command The show_temp command displays the board temperatures to the screen Syntax show temp Parameters None Example show temp Temperature near cross point top side is 50 Temperature near cross point bottom side is 44 C degree Temperature on input board is 43 C degree 55 RS 232 TELNET UDP COMMANDS show_user_name Command The show_user_name command displays the current TCP terminal user name Syntax show user name Parameters None Example show user name TCP Terminal login Administrator Zshow ver data Command The Zshow ver data command displays the hardware and firmware version ot the screen Syntax show ver data Parameters None Example show ver data Hardware version 2 Firmware Release version 60 2 Release date Jan 21 2013 Release time 16 38 56 Boot loader version 1 6 56 RS 232 TELNET UDP COMMANDS show_voltage Command The show_voltage command displays board voltages to the screen Syntax show voltage Parameters None Example show voltage Analog voltage 3 3 measured 3262 mV Analog voltage 1 8 measured 1781 mV Analog voltage 1 2 measured 1180 mV 57 RS 232 TELNET UDP COMMANDS f Command The command e
22. age EDID screen to access this menu system Select Input s to Set to Default Input 1 Input 2 Input 3 Input 6 Input 7 Input 8 Input 11 Input 12 Input 16 Set Default EDID Select Input s to Set to Default Input 2 Input 3 Input 7 Input 8 Input 12 Input 13 Set Default EDID Place a check mark next to the input s that should be set to the default EDID Click the Set Default EDID button to apply the default EDID to the selected inputs 65 WEB INTERFACE Upload EDID Upload EDID Press this button from the Manage EDID screen to access this menu system Input_1 a a ry Input_6 Input_7 Input_11 input 16 Default GEFEN XPT DL Select Input s to Upload to Input 1 lInput 2 Input 3 _ Input Input 6 Input 7 Input 8 Input Input 11 Input 12 Input 13 Input Input 16 Upload EDID File Load EDID file Load EDID file Place a check mark next to the input s that will receive the EDID data from the file The EDID file must be in bin format Click the Browse button to locate the EDID on the computer Click the Load EDID file button to upload the EDID file to the matrix 66 WEB INTERFACE Download EDID Download EDID Press
23. ank is located underneath the battery cover Remote Channel 0 Remote Channel 1 Default Remote Channel 2 Remote Channel 3 1 2 1 2 Left Picture of the opened rear battery compartment of the IR remote showing the exposed DIP Switch bank between the battery chambers It is important that the IR channel on the Remote Control unit matches the IR channel set on the 16x16 DVI Matrix w Push Button Control For example if both DIP switches on the IR Remote Control unit are set to IR channel 0 both DIP switches down then the 16x16 DVI Matrix w Push Button Control must also be set to IR channel 0 See page 54 on how to change the IR channel on the 16x16 DVI Matrix w Push Button Control 10 CONNECTING AND OPERATING THE 16X16 DVI MATRIX W PUSH BUTTON CONTROL How to Connect the 16x16 DVI Matrix w Push Button Control 1 Connect up to 16 DVI source devices to the DVI inputs on the rear panel of the 16x16 DVI Matrix w Push Button Control using the supplied DVI cables 2 Connect up to 16 DVI displays to the DVI outputs on the rear panel of the 16x16 DVI Matrix w Push Button Control using DVI cables 3 Connect the included AC power cable to the power receptacle on the rear panel of the 16x16 DVI Matrix w Push Button Control Connect the opposite end of the cable into an available electrical outlet Wiring Diagram DVI CABLE E RS 232 CABLE EE ETHERNET CABLE EE IP Control 7 RS 232 Controller 16x DVI
24. atrix must be rebooted after executing this command Example set tcp term pass Admin reindeer reindeer TCP Terminal password updated to reindeer 40 RS 232 TELNET UDP COMMANDS set_tcp_term_port Command The Zset tcp term port command sets the Telnet listening port The default port value is 23 Syntax set tcp term port paraml Parameters param1 Port 1 65535 Notes The matrix must be rebooted after executing this command Example set tcp term port 20 New TCP Terminal port set to 20 Zset udp port Command The Zset udp port command sets the local UDP listening port The default port value is 8 Syntax set udp port parami Parameters param 1 Port 1 65535 Notes The matrix must be rebooted after executing this command Example set udp port 10 New UDP listening port set to 10 41 RS 232 TELNET UDP COMMANDS set_udp_rip Command The Zset udp rip command sets the remote UDP IP address The default port value is 8 Syntax set udp rip paraml Parameters param 1 IP Address Notes The matrix must be rebooted after executing this command Example set udp rip 192 168 1 20 New remote UDP IP address set to 192 168 1 20 set_udp_rport Command The Zset udp rport command sets the remote UDP port Syntax set udp rport paraml Parameters param 1 Port Notes The matrix must be rebooted after executing this command Syntax set udp rpo
25. e 13 for more information on routing DVI sources PANEL LAYOUT Back Panel PANEL DESCRIPTIONS Back Panel IR Extender Port Connect an optional IR extender to this port AC 110 220 V AC 50 60 Hz Power Cable Receptacle Connect the included AC power cord from this receptacle to an available electrical outlet Fuse Drawer Each power receptacle houses a fuse drawer Within each fuse drawer are two 2 250 V fuses One fuse is active and the other is a spare DVI Input Ports 1 16 Connect DVI source devices to these ports IP Control Interface Connect to this port to control the 16x16 DVI Matrix w Push Button Control using IP Control See page 31 for more information on configuring IP settings Grounding Terminal Provides a discharge path to ground in case a short circuit occurs between the hot lead of the power supply and the enclosure of the Matrix The grounding wire should be attached from the grounding terminal to an approved ground path DVI Output Ports 1 16 Connect DVI monitors to these ports RS 232 Serial Port Connects to the RS 232 control device The 16x16 DVI Matrix w Push Button Control may be switched remotely using this port See page 30 for more information IR REMOTE DESCRIPTION RMT 16416IR Remote Control Unit 1 Activity Indicator This LED will be activated momentarily each time a button is pressed 2 Display and Source Selection Buttons 1 16 These buttons are used t
26. e can be recalled at a later time see Recalling a Saved Routing State Even if the matrix is powered OFF the presets will be retained in memory We ll illustrate an example by saving the routing state of Input 6 which we created on page 13 1 Press the PreSet button twice The PreSet button will glow bright blue indicating that it has been pressed The front panel display will indicate that the matrix is in save preset mode PRESET MODE SAVE CURRENT SET LE GU PRO 2 Select a preset memory location by pressing any of the first eight input buttons 1 8 The matrix supports up to eight preset locations For this example press the button 1 PRESET MODE SAVE CURRENT SET Sh PRO 3 Press the Set button to store the preset Set button Sh PRO PRESET MODE SAVE CURRENT SET continued on next page 16 PRESETS 4 The Set button will flash momentarily and the front panel display will indicate that the preset has been saved 5 After a few moments the front panel display will display the standby screen GEFEH 16416 IWI MATRIX 17 PRESETS Recalling a Saved Routing State The 16x16 DVI Matrix w Push Button Control allows saved routing and masking states to be recalled from memory for instant access In this example we will recall the routing preset that we stored in the previous example In order to clearly see how this process works try changing the routing state of Inpu
27. ed by the front panel buttons LEBBPLLIBELILIPPLILPLBPLBPLBPLPLBLL GEFEH GN BEE TTT E D H DH HH T E J i6 DVI MATRIX Le TO PRO 3 After a few moments the buttons will automatically turn off To immediately dismiss the routing status and return to the standby screen press the Cancel button Getting the Current Routing Status of an Output To display the current routing status of an output press the desired output button on the front panel of the matrix Once the output button is pressed the associated input will be displayed We ll continue with the previous example 1 Press the button for Output 3 on the matrix 2 The current routing status for Output 3 will be displayed by the front panel buttons BHENHNBHESNSNHHEHHHBBHHBHHEHHEB GEFEH 16x16 IVI MATRIX BEE BBH 3 After a few moments the buttons will automatically turn off To immediately dismiss the routing status and return to the standby screen press the Cancel button One to One Routing When an input output pair share the same number it is called one to one routing By default the 16x16 DVI Matrix w Push Button Control is shipped in one to one mode This means that Input 1 is routed to Output 1 Input 2 is routed to Output 2 and so on 15 PRESETS Saving the Current Routing State The 16x16 DVI Matrix w Push Button Control allows routing and masking states to be saved to internal non volatile memory Each routing stat
28. een carefully checked and is believed to be accurate However Gefen assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Gefen be liable for direct indirect special incidental or consequential damages resulting from any defect or omission in this manual even if advised of the possibility of such damages The technical information contained herein regarding the features and specifications is subject to change without notice For the latest warranty coverage information refer to the Warranty and Return Policy under the Support section of the Gefen Web site at www gefen com PRODUCT REGISTRATION Please register your product online by visiting the Register Product page under the Support section of the Gefen Web site 79 LICENSING This product uses software that is subject to open source licenses including one or more of the General Public License Version 2 and Version 2 1 Lesser General Public License Version 2 1 and Version 3 BSD and BSD style licenses Distribution and use of this product is subject to the license terms and limitations of liability provided in those licenses Specific license terms and Copyright Notifications are provided in the source code For three years from date of activation of this product any party may request and we will supply for software covered by an applicable license e g GPL or LGPL a complete machine readable copy of the corresponding open so
29. el 1 Press the Lock button The Lock button will glow bright blue indicating that the matrix is now locked The front panel display will also indicate that the matrix has been locked BEHHHNEHEHNEHHHHBHHHBHEHEHHBHEBEB LOCK MODE 2 To unlock the matrix press the Lock button again The Lock button will turn off and the front panel display will return to the standby screen GEFEHM 16416 IVI MATRIX LT GT PRO 25 EDID MANAGEMENT The 16x16 DVI Matrix w Push Button Control incorporates EDID management support Basic EDID functions such as storing EDID data to inputs can be performed using the buttons on the front panel Advanced EDID management features are controlled through the Web interface or by using EDID Management commands Saving the Downstream EDID to an Input 1 Press the EDID button once The EDID button will glow bright blue and the front panel display will indicate that the matrix is ready to copy the downstream EDID EDID DSTOLO MODE DSTOLO is an abbreviation for DownStream TO LOcal 2 Press the desired output For this example we are going to use the EDID of the display that is connected to Output 7 Therefore we will press the button for Output 7 E EDID STOLO MODE LT GT PRO continued on next page 26 EDID MANAGEMENT 3 Select the desired input where the EDID will be stored We will arbitrarily select Input 4 by pressing button 4 EDID DSTOLO MODE
30. he cable for use with Gefen products Pm Color Orange White 3 Green White NENNEN NN Blue White Cabling comes in stranded and solid core types Gefen recommends using solid core cabling It is recommended to use one continuous run from one end to the other Connecting through a patch is not recommended 76 RACK MOUNT SAFETY INFORMATION Maximum recommended ambient temperature 45 C 104 F Increase the air flow as needed to maintain the recommended temperature inside the rack Do not exceed maximum weight loads for the rack Install heavier equipment in the lower part of the rack to maintain stability Connect a bonding wire between an approval safety ground stud on the chassis T7 SPECIFICATIONS Maximum Pixel CIOCK Gem TERCER 165 MHz HPU Vd e SIAN cites ued ee noua niseundederaseanee senahenesecence R 1 2 Volts p p Video Input CODneclOl s sese eee eee 16 DVI I 29 pin female digital only Video output CONNECHOSMS cccccsseseeeeeeseeeeseeeeeseaees 16 DVI I 29 pin female digital only II EXIeDOBp oup d d UEM dU at DEAE 3 5 mm mini stereo 19 232 Intel d g ocio roeturnsbssid s des hurzy ceo Penbos cux suusba e tda emisse nex apad ida rreren DB 9 serial female is up qimesQieciood Q RJ 45 100BaseT Power SUPP y eros reene EEE sania artiside suma berto bn MUN EE 100 240 V AC Power CONSUMPUON P TR 90 Watts max Operating Temperature eee eee eee ee eee 32
31. mmand The prbaedid command reads the EDID file from the specified bank and sends it to the serial port Syntax prbaedid parami Parameters param1 EDID bank 1 3 Zprdsedid Command The Zprdsedid command reads the downstream EDID and sends it to the serial port Syntax prdsedid paraml Parameters param1 A downstream monitor 1 16 36 RS 232 TELNET UDP COMMANDS predidst Command The predidst command reads the downstream EDID This command displays a table containing details relating to the Local EDID and the monitor name Syntax predidst Parameters None prloedid Command The prloedid command reads the local EDID of a specified input and spools it to the serial port Syntax prloedid parami Parameters param1 Input 1 16 37 RS 232 TELNET UDP COMMANDS Command ipconfig resetip set http port set tcp term pass set tcp term port set udp port set udp rip set udp rport sgateway show_tcp_term_pass sipadd snetmask 4use tcp term pass use_udp access IP Configuration Displays all TCP IP settings Resets IP configuration to factory settings Sets the Web server listening port Sets the TCP terminal password Sets the Telnet listening port Sets the local UDP listening port Sets the remote UDP IP address Sets the remote UDP port Sets the IP gateway address Displays the current TCP password for login Sets the IP address of the
32. nables disables the 5V on the specified input Do not precede this command with the symbol WARNING Use caution when applying power to inputs If the source device supplies 5V on the input then enabling the 5V may cause damage to the source and or the 16x16 DVI Matrix w Push Button Control Syntax f paraml param2 Parameters param1 Input 1 16 param2 State 0 1 o Disable O Notes If param1 0 then all inputs will be affected Examples 15 1 Enable FO 15 f01 Enable All FO 58 RS 232 TELNET UDP COMMANDS m Command The m command displays the routing status in tabular form Do not precede this command with the 4 symbol Syntax m Parameters None Example m Output Input HPD Status Output 1 Input 1 LOW ACTIVE Output 2 Input 1 LOW ACTIVE Output 3 input 1 LOW ACTIVE Output 4 Input 1 LOW ACTIVE Output 35 Input 1 LOW ACTIVE Output 6 Input 1 LOW ACTIVE Output 7 Input 1 LOW ACTIVE Output 8 input i LOW ACTIVE Output 9 Input 1 LOW ACTIVE Output 10 Input 1 LOW ACTIVE Output 11 Input i LOW ACTIVE Output 12 Input 1 LOW ACTIVE Output 13 Input 1 LOW ACTIVE Output 14 Input 1 LOW ACTIVE Output 15 Input l LOW ACTIVE Output 16 Input 1 LOW ACTIVE GEFEN PRO Dynamic EDID mode RMT IR SW1 0 SW2 0 59 WEB INTERFACE View Matrix Status Matrix Status Displays the current routing status of each input and outpu
33. ntrolled via front panel buttons IR remote IP or RS 232 commands e Compatible with the Gefen Keyboard Controller software Advanced EDID management Programmable routing presets Standby mode e Output masking control IP control and configuration with built in Web server Internal power supply Rack mountable Package Includes 1 GefenPRO 16x16 DVI Matrix w Front Panel Push Button Control 16 6 ft DVI cables M M 1 IR Remote Control Unit 1 AC Power Cord 1 Quick Start Guide Front Panel PANEL LAYOUT Odd EEIEIE BERR REE REE EERE EES zL SLOW TAG Stet mms H TTT TH EEE on ae e RN TN aRar e e LE C L RT R n H e PANEL DESCRIPTIONS Front Panel Mode Buttons These buttons are used to control routing masking presets on the matrix See the information beginning with page 12 for more information Output Buttons 1 16 Used for routing an Input to an Output Each of these buttons represents an Output See page 13 for more information on routing DVI sources Power Indicator This LED indicator will glow red when the power is turned on LCD Display Displays the current routing status of the Matrix and is also used to manage source routing Power Used to power ON and power OFF the matrix IR Window Receives signals from the IR Remote Control unit Input Buttons 1 16 Used for routing an Input to an Output Each of these buttons represents an Input See pag
34. o select which source is routed to a monitor Routing Sources using the Remote Control unit Issuing a routing command is a two step process The first step is to select the monitor 1 16 to which the source will be routed The second step is to select the source 1 16 Example Route the source device connected to In 6 to the monitor connected to Out 4 1 Press button 4 Out 4 on the IR remote control unit 2 Press button 6 In 6 on the IR remote control unit The source connected to In 6 will be routed to the monitor connected to Out 4 IR REMOTE INSTALLATION Installing the RMT 16416IR Battery 1 Remove the battery cover on the back of the IR Remote Control unit 2 Insert the included battery into the open battery slot The positive side of the battery should be facing up 3 Replace the battery cover The Remote Control unit ships with two batteries One battery is required for operation and the other battery is a spare Battery Slot WARNING Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions IR REMOTE CONFIGURATION How to Resolve IR Code Conflicts In the event that IR commands from other remote controls interfere with the supplied IR Remote Control unit changing the IR Remote Control s IR channel will fix the problem The IR Remote Control unit has a bank of DIP switches used for setting the IR channel The DIP switch b
35. put 12 Input 13 Select Source to Copy from Select Input s to Copy to Click the radio button next to the input or output containing the EDID to copy Note that only a single input or output can be selected at a time Place a check mark next to the input s where the EDID will be copied Click the Set EDID button to confirm the operation 68 WEB INTERFACE EDID Lock State EDID Lock State Press this button from the Manage EDID screen to access this menu system EDID Lock State Update EDID LockState Off O On Update EDID Lock State Secures the Local EDID and disables the automatic loading of the downstream EDID after the Matrix is powered on Select the radio button next to the Off or On option then click the Update EDID Lock State button to apply the change The EDID Lock State has no effect when the Dynamic EDID function is activated 69 WEB INTERFACE Masking Matrix Mask Status Change Displays the current masking status for each output Matrix Mask Status Change Output Input Status Click to See fscif me Output Input 1 Mask Active b e n GET Output 10 Mask mee Click to save the masking changes Output 13 Input 2 Mask Te ZTE Save Changes Mask Click the Mask button to mask the selected output If the output is already masked then the button will read
36. rt 4096 New remote UDP port set to 4096 42 RS 232 TELNET UDP COMMANDS sgateway Command The sgateway sets the IP gateway router address Dot decimal notation must be used when specifying the IP address The default gateway is 192 168 1 254 Syntax Sgateway paraml Parameters param1 IP gateway Notes The matrix must be rebooted after executing this command Example Sgateway 192 168 1 1 New IP Gateway set to 192 168 1 1 show tcp term pass Command The Zshow tcp term pass command displays the current TCP password for login if required Syntax show tcp term pass Example show tcp term pass TCP Terminal password reindeer 43 RS 232 TELNET UDP COMMANDS sipadd Command The sipadd command sets the IP address of the matrix Dot decimal notation must be used when specifying the IP address Syntax Sipadd paraml Parameters param1 IP address Notes The matrix must be rebooted after executing this command Example sipadd 192 168 1 239 New IP set to 192 168 1 239 snetmask Command The Zsnetmask command sets the IP network mask Dot decimal notation must be used when specifying the IP network mask Syntax Snetmask parami Parameters param1 Network mask Notes The matrix must be rebooted after executing this command Example snetmask 255 255 255 0 New IP Mask set to 255 255 255 0 44 RS 232 TELNET UDP COMMANDS Zuse tcp
37. s Save Current Routing State to Preset Save Preset Recall Routing State Recall Preset Recall Preset Click the down arrow on the pull down list to select the routing state 1 16 to recall Click the Recall Preset button to recall the preset Save Preset Click the down arrow on the pull down list to select the preset location 1 16 Click the Save Preset button to save the preset 62 WEB INTERFACE CC 16x16 DVI Manager VIEW MATRIX STATUS MANAGE EDID MASKING IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT SE Active Lent 2 inpat_1 Active Dynamic EDID Mode Output 3 Imput 1 Active Update Dynamic EDID State Of On Output_4 input 1 Active Switch Outputs Outputs JOutput 2 JOutput 3 Output_4 JOutput 5 lOutput 6 T 5 Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Output 16 Inputs D Input 1 t E D Input_5 E Input 7 Input 8 Input_9 erat 10 D Input_11 D Input_12 O input 13 Input 14 Input 15 Input 16 Swich C Auto Refresh Presets Save Current Routing State to Preset 1 v Recall Routing State 1 RecallPreset Rename UO Output Outpui Name Save Output Name Save Input Name Rename I O Provides custom naming of each input and output on the matrix Output Output Name 1 E O
38. ss the Set button The Set button will flash momentarily Set button EDID DETOLO MODE 4 Once the Set button is pressed the matrix will begin copying the default EDID to the specified input The front panel display will indicate that the matrix is copying the EDID 5 After the EDID has been successfully copied to the selected input the front panel display will show the following message 6 After a few moments the selected buttons will turn off and the front panel display will return to the status screen 29 RS 232 IP CONTROL RS 232 Interface 54 3 2 1 RS 232 Controller Matrix oO ON O a A CQ N gt oO ON O Oa A CQ N gt Only TXD RXD and GND are used RS232 Settings Ba dtate enren e E E 19200 B He LU T E 8 SS OILS R H R PIN MN CMM I RIZ MINE MCI MGE None OP D ETE I E T E 1 eder I nen tamaatactadtieda stata tantenadtadaetecuustetdecadia E sa None IMPORTANT When sending RS 232 commands a carriage return must be included at the end of the command A space must be included between the command and the parameter 30 RS 232 IP CONTROL Using Syner G When using this product for the first time it is recommended that the unit be configured using the Gefen Syner G Software Suite The Gefen Syner G Software Suite is free software that is available from the Gefen Web site 1 Download and install the Gefen Syner G Software
39. t 6 to Output 2 Then use the steps below to recall the original routing state 1 Press the PreSet button once The PreSet button will glow bright blue indicating that it has been pressed The front panel display will indicate that the matrix is in recall preset mode BEER BBH PRESET MODE EEE PERE REE ERE EEG RECALL SAVED SET LE GU PRO 2 Since we stored our preset in Preset 1 press the button for Input 1 to recall the routing state BER BEER EERE EERE EE PRESET MODE RECA BEE SER ER ER ERE ES LE GU DEO 3 Press the Set button to recall the routing state from the selected location Set button ST PRO PRESET MODE RECA LL SAVED SET 18 PRESETS 4 The Set button will flash momentarily and the front panel display will indicate that the preset has been recalled 5 After a few moments the front panel display will display the standby screen GEFEH 16416 IWI MATRIX 19 MASKING Masking Outputs Masking prevents the output device display etc from receiving an output signal Instead of powering down or disconnecting the output device individual or multiple outputs can be masked Inputs cannot be masked To illustrate masking we ll use our original routing example from the section Routing Inputs to Outputs 1 Press the Mask button The Mask button will glow bright blue and the front panel display will indicate that the matrix is in mask mode BEER BEERS MASK
40. t on the matrix GED 16x16 DVI Manager VIEW MATRIX STATUS MANAGE EDID MASKING IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT oup input Stans Matrix Status ounn moni ace Output 8 Input 1 Active JF EE HIE it ET L Auto Refresh Refresh Auto Refresh Click to refresh the Matrix Check this box to enable Auto Refresh Status screen The Auto Refresh function automatically refreshes the interface every 10 seconds 60 WEB INTERFACE Dynamic EDID Mode Routes any downstream EDID to any input See the dynamic_edid command on page 33 for details on this feature Options On Off Click the Update Dynamic EDID State button after selecting either On or Off Dynamic EDID Mode Update Dynamic EDID State O Off On OWER MANAGEMENT i Output Input Sta EMEN Dynamic EDID Mode Update Dynamic EDID State Off On Dompu 3 impuni Active Compa ngu 1 Active F output S input 1 Acive Switch Outputs Outputs T Output_1 L Output 7 _ Output 13 Output 3 Output 4 Output 5 _ Output_6 Output 9 Output_10 JOutput 11 Output 12 Output 15 1Output 16 Inputs Input 1 Input_3 O Input_4 Input 5 Input 6 Input 7 Input 9 Input 10 O Input_11 D Input 12 Input 13 Inp
41. tion when a ae 388838 Input _ BEDEO P 4 o 3 92999289 d T a IL om ovs Power Lock State inputs OFF ON Update Power Lock State Of ween or ON wa orm ou siea ena eR N mms om ON ELE SECIN 4l Auto Refresh Save Changes Save Changes Click to save the power lock status 74 Power State The current power state is listed under the column titled 5 Volt Click these buttons to toggle the input power state Auto Refresh Check this box to automatically update the screen every 10 seconds WEB INTERFACE GED 16x16 DVI Manager VIEW MATRIX STATUS MANAGE EDID MASKING IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT Warning Use caution when applying power to inputs It may damage your equipment Power Status Lock State OFF Power Lock State Update Power Lock State Of Power Lock State Update Power Lock State Power Lock State In the case of an accidental power loss to the matrix the 5V state for each input can be preserved Set the specified Power Status buttons see previous page and click the radio button next to ON Click the Update Power Lock State button to apply changes By default this option is set to Off 75 NETWORK CABLE WIRING DIAGRAM Gefen recommends the TIA EIA 568 B wiring option Please adhere to the table below when field terminating t
42. to 104 F 0 to 40 C Storage Temperature ee ee eee 4 to 140 F 20 to 60 C Relative Humid 20 to 90 RH no condensation Dimensions W x H x D sese ee 17 25 x 3 5 x 12 438mm x 89mm x 305mm Rack mountable sese ee RR TR 2U rack space rack ears included MONI VV e TTT 30 Ibs 13 6 kg 78 WARRANTY Gefen warrants the equipment it manufactures to be free from defects in material and workmanship If equipment fails because of such defects and Gefen is notified within two 2 years from the date of shipment Gefen will at its option repair or replace the equipment provided that the equipment has not been subjected to mechanical electrical or other abuse or modifications Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair Such repairs are warranted for ninety 90 days from the day of reshipment to the Buyer This warranty is in lieu of all other warranties expressed or implied including without limitation any implied warranty or merchantability or fitness for any particular purpose all of which are expressly disclaimed 1 Proof of sale may be required in order to claim warranty 2 Customers outside the US are responsible for shipping charges to and from Gefen 3 Copper cables are limited to a 30 day warranty and cables must be in their original condition The information in this manual has b
43. trix This preserves the 5V state when the unit is restarted syntax lock fo paraml Parameters param1 State 0 1 o Disable power lock Enable power lock Example lock fo 0 Disable Lock power mode 53 RS 232 TELNET UDP COMMANDS set_input_name Command The Zset input name command provides a name to the selected input For example Input 1 could be renamed as Computer 1 The maximum string length for param2 is 15 characters Special characters and spaces are not permitted If required use the underscore character to separate characters Syntax set input name paraml param2 Parameters param1 Input 1 16 param2 Name Example set input name 5 computerl computerl is assigned to input 5 set_ir Command The set_ir set the IR channel for the matrix The associated DIP switch settings for the IR remote control unit are returned See page 10 for details on setting the IR channel for the IR remote control Syntax set ir parami Parameters param1 Channel 0 3 Example set ir 2 RMT IR SW1 0 SW2 1 54 RS 232 TELNET UDP COMMANDS set_output_name Command The set_output_name command provides a name to the selected output For example Output 1 could be renamed as HDDisplay The maximum string length for param2 is 15 characters Special characters and spaces are not permitted If required use the underscore character to separate char
44. ts Getting the Current Masking State Unmasking Outputs Locking the Matrix EDID Management Saving the Downstream EDID to an Input Saving the Default EDID to an Input RS 232 IP Control RS 232 Interface RS 232 Settings Using Syner G RS 232 Telnet UDP Commands EDID Management IP Configuration Routing Masking Miscellaneous Web Interface View Matrix Status Manage EDID Masking IP Configuration Backup Restore Power Management Network Cable Wiring Diagram Rack Mount Safety Information Specifications Warranty Licensing INTRODUCTION Congratulations on your purchase of the GefenPRO 16x16 DVI Matrix w Front Panel Push Button Control Your complete satisfaction is very important to us GefenPRO In the realm of video distribution certain features are invaluable in a commercial or broadcast environment Accommodations such as a build in power supply and flat black rack mount enclosures set GefenPRO apart from our traditional products Complex distribution units allow for professional DVI 3G SDI and HDMI signals to be routed and converted easily and seamlessly while being backed up by a renowned and dependable technical support team Gefen invites you to explore the GefenPRO product line and hopes that you find the solution that fits your needs The GefenPRO 16x16 DVI Matrix w Front Panel Push Button Control Simplify the process of routing up to 16 DVI sources to any of 16 DVI monitors without losing quality or resolution
45. urce code on a medium customarily used for software interchange The following software and libraries are included with this product and subject to their respective open source licenses e IwIP freeRTOS jQuery IwIP is licenced under the BSD licence Copyright c 2001 2004 Swedish Institute of Computer Science All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that the following conditions are met 1 Redistributions of source code must retain the above copyright notice this list of conditions and the following disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the documentation and or other materials provided with the distribution 3 The name of the author may not be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED BY THE AUTHOR AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY T
46. ut_ Switch Outputs Outputs Output 1 Output 2 L Output 7 Qutput 8 Output 9 Outp Output 13 Qutput 14 Inputs C Input 1 O Input 2 Input_3 Input O Input 7 Input 8 C Input_9 D Input O Input_13 O Input_ 14 O Input_15 C Input Switch Switch Outputs Used to route the specified input to the selected output s To route a source place a check mark next to each Output Next click the radio button next to the desired Input Press the Switch button to apply the routing change 61 WEB INTERFACE GES 16x16 DVI Manager VIEW MATRIX STATUS MANAGE EDID MASKING IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT Dynamic EDID Mode Update Dynamic EDID State Off On Switch Outputs Outputs Output 1 JOutput 2 Output 3 Output 4 Output 5 lOutput 6 Output 7 Output 8 Output 9 Output 10 Output 11 Output 12 L Output 13 Output 14 Output 15 Output 16 Inputs Input 1 Input 2 Input 3 Input 4 D Input 5 Input 6 Input_7 D Input_8 Input_9 O Input_10 D Input_11 D Input_12 Output_15 Input 1 Actwe input_13 gt Input_14 Input_15 Input_16 Output_16 Input 1 Active on C Auto Refresh Presets Save Currint Routing State to Preset 1 Recall Routi g State ly Rename UO Output Output 1 Ouput Input Input Name Presets Provides saving and recalling of routing states Preset
47. utput 1 Save Output Name Input Input Name 1 Input 1 Save Input Name Input Select the DVI input to rename from the pull down list Type the name of the input in the Input Name field Click the Save Input Name button to save changes See page 53 for naming restrictions Output Select the DVI output to rename from the pull down list Type the name of the output in the Output Name field Click the Save Output Name button to save changes See page 55 for naming restrictions 63 WEB INTERFACE Manage EDID EDID Status Displays the current EDID status for each input on the matrix See page 36 for more information on locking the EDID GES 16x16 DVI Manager VIEW MATRIX STATUS MASKING IP CONFIGURATION BACKUP RESTORE POWER MANAGEMENT Set Input to Default EDID Defaut GEFEN JT inputs Detur GEFEN XPT Di re Defaut GEFEN XPT D el Defaut GEFEN M EX SZ Input 2 Default EIE mas Detur GEFEN ver D el veu eeren er oL put TEN XPT pai Owed GEFEUPT Input 5 GEFEN XPT DL Input 6 GEFEN XPT DL GEFEN JT DL Defaut Refresh STER Click to refresh ans Status Input 13 GEFEN XPT Refresh Auto Refresh Auto Refresh Check this box to enable Auto Refresh Auto Refresh will automatically update the screen every 10 seconds 64 WEB INTERFACE Set Input to Default EDID Set Input to Default EDID Press this button from the Man
Download Pdf Manuals
Related Search
Related Contents
dossier de candidature Agenda 21 local France - DRIEE Ile-de Hazardous Materials Disposal Handbook – Chemical Waste Descargar manual de uso manual de instalação & modo de utilização do 山岳トイレ技術分野における検討内容と実施状況 Manual COMPUTER GUIDE 2012 SA-Inform Messaging System User Manual Version 1.3.2 "Ci diamo una sistemata" di Obi Copyright © All rights reserved.