Home
Mobeye CM-Guard CM2000 - Compound Security Systems
Contents
1. mobeyc Mobeye CM Guard CM2000 SW version 1 n Attention Very important This user manual contains important guidelines for the installation and usage of the Mobeye device as described in this manual Please read these thoroughly before you start using the Mobeye device In case of damage caused by disregarding the guidelines the warranty expires The user must regularly check the proper functioning of the device The manufacturer cannot be held liable for any damage caused by any incorrect use or incorrect functioning of the Mobeye device Safety guidelines The permitted ambient temperature during operation may not be exceeded not lower than 10 C and not higher than 50 C The device is intended for use in dry and clean places e Protect the device from moisture heat and water splashing The guidelines for the battery usage must be regarded e Do not expose the device to strong vibrations e Do not let it fall from height Do not use in an environment where any inflammable gases vapors or dust are present or could be present The repairs of the device may only be carried out by people trained for Mobeye repair e In case the device must be repaired only original replacement components may be used The use of different parts may lead to damage of the Mobeye device Use in accordance with the regulation The use of this device in accordance with the regulation is sending SMS text messages and mak
2. a new alarm message is sent The time can be set between 0 and 60 minutes As default the inactive time is set to 0 SMS command inactive time input 1 lt CODE gt INACTIVEIN1 xx SMS command inactive time input 2 lt CODE gt INACTIVEIN2 xx 4 4 9 Alarm repeat time In order to emphasize the urgency of the alarm messages all alarms can be repeated As long as the alarm status has not returned to the inactive status the SMS alarm will be repeated after the alarm repeat time The time can be set between 0 and 24 hours As default the alarm repeat time is set to 4 hour SMS command alarm repeat time lt CODE gt REPEAT xx 4 4 10 Test SMS text message The Mobeye CM Guard can send regular test SMS messages keep alive to the administrator to ensure the proper functioning of the unit The test message function is only active in case the unit is armed The interval between the test messages can be set between 0 days no test message and 30 days The default test interval is set to 0 no test message SMS command interval test message lt CODE gt TEST xx 4 4 11 Power failure SMS message In case the Mobeye CM Guard is powered externally and the power fails it sends an SMS text message to the administrator The message is only sent in case the unit is armed This message can be set to OFF The default setting for the power failure SMS text message is set to ON SMS command power failure message l
3. be aware of the space behind 1111 1111 DEL1 Release the button immediately after the LED starts to flash After a successful reset the status LED on the keypad will blink green to indicate that the module is not configured The security code lt CODE gt is back to factory settings as well 5 REQUEST LIST OF THE SETTINGS AND STATUS The programmed settings and status of the GSM detector can be received per SMS message Before sending the request make sure the unit is in the program mode please refer to 4 1 5 1 STATUS REQUEST The status of the Mobeye CM Guard can be requested by sending an SMS with the content lt CODE gt STATUS Upon sending this request the Mobeye CM Guard returns the status to the originator of the request The status message includes the ARMED NOT CONFIGURED status of the Mobeye CM Guard the status of the inputs power and batteries 5 2 LIST OF GENERAL SETTINGS The general settings of the Mobeye CM Guard can be requested by sending an SMS with the content lt CODE gt SET Upon sending this request the Mobeye CM Guard returns the list of programmed settings to the originator of the request 5 3 LIST OF PHONE NUMBERS The list of telephone numbers can be requested by sending an SMS message with the content lt CODE gt CALL Upon sending this request the Mobeye CM Guard returns the list of programmed telephone numbers to the originator of the request 6 TECHNICAL MESSAGES AND STATUS FE
4. This user manual meets the technical requirements at the moment of printing Changes in technology and equipment are reserved Copyright 2013 by Mobeye version CM2000EN130331 11 ce Declaration of Conformity Herewith we Mobeye declare that the product Mobeye CM21 telemetry module And the derived products CM2000 CM2100 CM2200 CM2300 CM2300FS CM2400 CM2500 are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low voltage directive Directive IEC EN 50130 Electromagnetic compatibility Directive 1995 5 EC R amp TTE Radio amp Telecommunications Terminal Equipment The conformity with the essential requirements of 1995 5 EC has been verified against ETSI EN 301 489 1 V1 5 1 ETSI EN 301 489 7 V1 2 1 ETSI EN 301 511 V9 0 2 CENELEC EN 60950 2001 Mobeye B V Poeldonkweg 5 5216 JX s Hertogenbosch The Netherlands Name J P K van de Vijver Position General Manager 31 maart 2013 12
5. Use the indication for the correct placement The green LED will flash to indicate that the module is not configured at least one telephone number should be programmed 2 4 ENTER THE PROGRAM MODE Directly after placing the batteries the Mobeye CM Guard switches to the program mode First the GSM module establishes network connection During this time the LED flashes 2 sec on 1 sec off Within 10 30 seconds the connection is established and the status LED starts flashing 1 sec on 1 sec off or on in case the first telephone number has been configured The Mobeye CM Guard returns to the program mode by pressing the on off button during 5 seconds until the LED starts flashing or turns to on As long as the unit is in the program mode the status LED is on or flashing 1 sec on 1 sec off if the module has no configuration During the first 3 minutes the GSM module remains open ready to receive SMS commands After 3 minutes a time out occurs and the GSM module switches off in order to save the batteries The unit returns to the low power operational mode 2 5 PROGRAM AT LEAST ONE TELEPHONE NUMBER The Mobeye CM Guard is able to send messages up to 5 telephone numbers The first telephone number belongs to the administrator Technical messages like battery low are sent to the administrator only Without the administrators phone number the Mobeye CM Guard cannot not function When the CM Guard is in initi
6. AME lt free text gt 4 4 3 Alarm text Unique alarm texts can be programmed into the Mobeye CM Guard User defined texts have a maximum length of 20 characters Following default texts are programmed Triggered input 1 lt TEXT1 gt Alarm 1 Triggered input 2 lt TEXT2 gt Alarm 2 SMS commands text 1 lt CODE gt TEXT1 lt free text gt SMS commands text 2 lt CODE gt TEXT2 lt free text gt 4 4 4 Alarm notification type SMS or SMS call As default behaviour after an activated input the Mobeye CM Guard notifies by SMS text message followed by a telephone call beep signal The combination of SMS text and the call increases the chance of getting the attention of the contact persons It is possible to disable the call OFF so that only an SMS message will be sent The default alarm notification type is ON SMS call SMS command alarm notification type lt CODE gt CALL xxx 4 4 5 Input type The input type defines the character of the inputs IN1 and IN2 This can be Normally Open NO or Normally Closed NC In case an input is set to NO the alarm will be triggered as soon as the terminals of the input are closed If the input is set to NC the alarm is triggered in case the connection between the input terminals is broken The default input type is set to NO SMS command input type input 1 lt CODE gt TYPEIN1 xx SMS command input type input 2 lt CODE gt TYPEIN2 xx 4 4 6 Exit delay time The exit delay time define
7. EDBACK Technical messages In case of technical issues the administrator receives an SMS message Possible technical messages are Message Reason Low batteries external power supply Power is available batteries need to be replaced OK No external power supply batteries No external power supply batteries are capable to take OK over operation in low power mode Low batteries no external power No external power supply batteries need to be replaced supply External power supply OK batteries The external power is restored or the adapter is plugged in OK a socket batteries do not need to be replaced Message s missed due to One or more SMS text messages couldn t be sent due to a Network SIM failure SIM card failure or GSM network failure When receiving one of the above mentioned technical messages please take appropriate action as soon as possible During the battery replacement the SIM card does not have to be removed Status feedback Status LED pattern Required action Module not configured Blinking 1 second on 1 Configure at least one telephone second off number Module is switched on powered by 1 flash every 3 seconds No action required batteries Module is switched on powered by On No action required an external source Module establishes network Blinking 2 seconds on 1 Wait until the network connection is connection to send an alarm second off established a
8. Guard cause following reactions Incase one of the inputs is activated by a sensor the Mobeye CM Guard sends an alarm SMS text message and calls to the phone numbers as programmed by the user Incase one of the inputs remain in the alarm status the Mobeye CM Guard repeats sending the SMS alarm message every four hours Incase the batteries need to be replaced the Mobeye CM Guard sends a battery low SMS text message to the administrator Incase an external power supply is used and a power failure occurs the Mobeye CM Guard sends a power failure SMS text message to the administrator In case the power is restored the Mobeye CM Guard sends a power restored SMS text message to the administrator 2 GETTING STARTED To get started with the Mobeye CM Guard at least the following steps need to be taken in following order Place a SIM card with PIN code 0000 or without PIN code Connect a sensor to the input Place the batteries Enter the program mode Program at least one telephone number administrators number Arming disarming the system OOORODP These steps are further explained in this chapter After these steps the module will be operational 2 1 PLACE A SIM CARD Open the enclosure with the 4 screws and insert a SIM card into the module Push the black cover outward slightly to open the holder Before installing the SIM card should have PIN code 0000 or be free of a PIN code A PIN code can be cha
9. al factory status and the batteries are placed so the LED is flashing the administrators number is programmed by calling the telephone number of the Mobeye CM Guard using the administrators phone The unit will recognize this number and store it as administrator telephone number 1 The administrator will receive a confirmation SMS text message including the security code This code is needed to program the other settings in the unit NB for this way of programming the number recognition in the administrator s phone must be on To program or change the administrators number by SMS command please refer to 4 4 1 2 6 SWITCHING ON OFF After the previous steps the Mobeye CM Guard is ready for use It is armed switched on automatically The green LED blinks once in 3 seconds In order to switch off disarm the Mobeye CM Guard Press the on off button at the upper side for 1 second The green LED switches off to indicate the armed status In order to switch on arm the Mobeye CM Guard Press the on off button at the upper side for 1 second The green LED blinks once in 3 seconds or permanently in case of an external power supply to indicate the armed status 3 USE OF EXTERNAL POWER SUPPLY Although the Mobeye CM Guard is designed to run on batteries it is possible to use an external power supply In this mode the module is always in connection with the GSM network and therefore always in program mode In case th
10. e power fails the batteries take over the functioning and the administrator is informed by an SMS text message The module continues operating albeit in the low power mode This means the GSM module switches off and only establishes network connection in case it needs to send out an alarm test message or battery low alert Connect the external power adapter or any other regulated 12VDC power supply to the power input of the connector press on the green pins for connecting the wires V black lead with white stripe to Ground black lead to 0 I O O ozfpo0 25 000 C Ni 4 EXTENDED OPTIONS To program the Mobeye CM Guard the GSM module must have network connection In case only batteries are used first switch the unit to the program mode Next send SMS commands for the configuration All settings are stored and will be kept in the unit even in case the power supplies are removed 4 1 PROGRAM MODE Directly after placing the batteries the Mobeye CM Guard switches to the program mode First the GSM module establishes network connection During this time the LED flashes 2 sec on 1 sec off Within 10 30 seconds the connection is established and the status LED starts flashing 1 sec on 1 sec off or on in case the first telephone number has been configured The Mobeye CM Guard returns to the program mode by pressing the on off bu
11. ing telephone calls after an alarm situation Other usages are not permitted Battery recycling CR123 batteries as used in the Mobeye CM Guard are classified as non hazardous waste and can be recycled Please take empty batteries to a nearest collection point CONTENT 1 2 General description Getting started Place a SIM card Connect a sensor to the input Place the batteries Enter the program mode Program at least one telephone number Switching on off Use of external power supply Extended options Program mode The security code Programming the settings by SMS Possible general settings Phone numbers Identification text Alarm text Alarm notification type SMS or SMS call Input type Exit delay time Input delay time Inactive time Alarm repeat time Test SMS text message Power failure SMS message List of SMS commands for configuration Reset of system Request list of the settings and status Status request List of general settings List of phone numbers Technical messages and status feedback as O OOOO OO NYUUUNOOOOOOOOOIO O A WWWNHNNDN 1 GENERAL DESCRIPTION The Mobeye CM Guard is a battery operated GSM module used to send out an alarm after a triggered input or if external power supply is used after a power failure The Mobeye CM Guard is pre programmed with standard action reaction patterns To change this behaviour please refer to chapter 4 The factory settings of the Mobeye CM
12. nd the message is message sent Module establishes network Blinking 3 seconds on 1 Wait until the network connection is connection to get to program mode second off established before programming No GSM connection 2 flashes every 3 Try the SIM card in any mobile seconds telephone replace SIM card using other telecom provider try the module at another location No valid SIM card or wrong PIN 3 flashes every 3 Try the SIM card in any mobile seconds telephone remove PIN code check credit replace SIM card Successful programming action Blinking 3 times No action required Faulty programming action Flashing 5 times Check SMS command Low batteries 4 flashes every 3 Replace both batteries seconds 10 Technical specifications GSM Quad band EGSM 850 900 1800 1900 MHz Antenna 900 1800 1900 MHz Batteries 2 CR123 lithium Battery life in normal mode gt 1 year Ext power connection 12 VDC 2 VDC min 500 mA optional Power consumption low power ca 50 HA stand by max ca 500 mA Power consumption 12V ca 50 mA stand by max ca 500 mA Dimensions 80 x 60 x 40 mm Ambient temperature 10 C until 50 C This manual is published by Mobeye All rights the translation included are reserved Any reproduction either photocopy microfilm or saved in an automated data dictionary only after written approval of the Publisher Reprinting even in summary is prohibited
13. nged or removed by putting the SIM card in a mobile phone and change or remove the PIN in the security menu NB make sure the SIM card is inserted before the batteries are placed In case of a SIM card change please first remove the batteries and remove any other external power supply 2 2 CONNECT A SENSOR TO THE INPUT Two external sensors can be connected to the inputs As a standard d HE a reaction after a triggered input the Mobeye CM Guard sends an SMS o ong O text message to the preset numbers and calls these numbers y gt CM2 Insert the 2 wires of an external sensor through the hole of the o o 9 i enclosure to the inside part and next in the two connectors of input 1 _ press on the green pins for connecting the wires It does not matter 2 i which wire is connected to which connector If necessary the wires can be extended up to 5 meters using appropriate wire material When using a second input connect this to input 2 As default the inputs are programmed as Normally Open NO je contacts This means the inputs are triggered in case the input is closed during at least 1 second In case the contact should be Normally Closed NC please refer to paragraph 4 4 4 In case a sensor should be activated shorter or longer before evoking an alarm please refer to 4 4 6 2 3 PLACE THE BATTERIES Place the two batteries CR123 in the module
14. ommand1 gt f lt command2 gt lt commandN gt The green LED blinks 3 times to indicate the successful configuration In case of an incorrect command the LED flashes 5 times In 4 5 the complete scheme with SMS commands is listed 4 4 POSSIBLE GENERAL SETTINGS This paragraph describes the general settings for the CM Guard 4 4 1 Phone numbers The Mobeye CM Guard is able to send alarm messages up to 5 phone numbers The first telephone number TEL1 belongs to the administrator Only this number receives all system messages The other phone numbers including the administrator only get the alarm messages To set or change telephone numbers SMS command 1 telephone number lt CODE gt TEL1 lt tel number gt SMS command 2 telephone number lt CODE gt TEL2 lt tel number gt similar for TELS TELS To delete telephone numbers SMS command delete 1 telephone number lt CODE gt DEL1 similar for DEL2 DEL5 In case a foreign number needs to be entered start with 00 followed by the country code Example 1111 TEL1 004461 2345678 4 4 2 Identification text It is possible to add a standard identification text NAME to all messages sent out by the Mobeye CM Guard The alarm messages are a combination of the name and the alarm text A user defined identification has a length of maximum 20 characters The default identification text is Mobeye SMS command identification text lt CODE gt N
15. s the time between the moment of switching on the module while the input is active and the moment the module starts sending the first alarm message Example the module was installed in a cabinet where a door magnet contact is connected to the input The exit delay time is the time between switching on the module and closing the cabinet s door As soon as this time has exceeded the alarm message will be sent The time can be set between 0 and 999 seconds As default the exit delay time is set to 1 second SMS command exit delay input 1 lt CODE gt DELAYEXIT1 xxx SMS command exit delay input 2 lt CODE gt DELAYEXIT2 xxx 4 4 7 Input delay time The input delay time defines the time that the input are triggered before an alarm is initiated If the input returns to the non alarm status within the delay time no alarm is sent The time can be set between 0 and 999 seconds As default the input delay time is set to 1 second SMS command alarm delay input 1 lt CODE gt DELAY1 xxx SMS command alarm delay input 2 lt CODE gt DELAY2 xxx 4 4 8 Inactive time The inactive time defines the time input 1 or input 2 is not active after an activation In case the time is set to 0 minutes the input is active again immediately after returning to the non alarm status In case the time is set to e g 30 minutes the input remains inactive for the first 30 minutes In case the input is again or still activated after these 30 minutes
16. t CODE gt POWERSMS xx 4 5 LIST OF SMS COMMANDS FOR CONFIGURATION Setting SMS Command Range Default value Change security code INSTCODE lt xxxx gt 0000 9999 1111 Set telephone number for TEL1 lt tel number gt Empty alarm messages ate TEL5 lt tel number gt Delete telephone number DEL1 DEL5 Identification text NAME lt text gt 20 characters Mobeye Alarm notification type CALL lt type gt ON OFF ON Input type TYPEIN1 lt type gt NO NC NO TYPEIN2 lt type gt Exit delay input 1 DELAYEXIT1 lt sec gt 0 999 sec 0 Exit delay on input 2 DELAYEXIT2 lt sec gt 0 999 sec 0 Delay on input 1 DELAY 1 lt sec gt 0 999 sec 1 Delay on input 2 DELAY2 lt sec gt 0 999 sec 1 Inactive time input 1 INACTIVEIN1 lt min gt 0 60 min 0 Inactive time input 2 INACTIVEIN2 lt min gt 0 60 min 0 Alarm repeat time REPEAT hh 0 24 hrs 4 Alarm text input 1 TEXT1 lt text gt 20 characters Alarm 1 Alarm text input 2 TEXT2 lt text gt 20 characters Alarm 2 Interval test SMS TEST lt days gt 0 30 days 0 Power failure SMS POWERSMS lt xx gt ON or OFF ON Examples Set phone number1 Delete phone number1 4 6 RESET OF SYSTEM To reset the Mobeye CM Guard to its factory settings Remove the batteries Press the outside button while entering the batteries Keep it pressed for about another 5 seconds 1111 TEL1 0612345678
17. tton during 5 seconds until the LED starts flashing or turns to on As long as the unit is in the program mode the status LED is on or flashing 1 sec on 1 sec off in case the module has no configuration During the first 3 minutes the GSM module remains open ready to receive SMS commands After 3 minutes a time out occurs and the GSM module switches off in order to save the batteries The unit returns to the low power operational mode In case the unit is connected to an external power supply the CM Guard has network connection all the time and the unit is in program mode all the time The program mode is interrupted by pressing the on off button during one second until the LED switches off The unit is switched off completely disarmed 4 2 THE SECURITY CODE For configuration activities the security code of the Mobeye CM Guard must be used The initial security code is 1111 In this manual this code is referred to as lt CODE gt 4 3 PROGRAMMING THE SETTINGS BY SMS The settings are programmed by SMS text messages Be sure the CM Guard is in program mode please refer to 4 1 Send an SMS message with following content lt CODE gt lt command gt Do not forget the space character between lt PIN code gt and lt command gt The commands are case sensitive Several commands may be combined in one SMS message with a maximum of 160 characters by placing a between the commands lt CODE gt lt c
Download Pdf Manuals
Related Search
Related Contents
ASUS SK7825 User's Manual Asahi Pentax ZX-L Operating Manual LE CROUX - Réseau Ecole et Nature Manual T.cnico Monicel GPRS Universal Rev5.pmd 【取扱説明書】はこちら Sharp MX-B402SC Brochure TD 7000 - Final OK Samsung Galaxy Tab A avec S Pen (9,7) Samsung HMX-F80BP Korisničko uputstvo PVD3322 : Manuel de mise en service pour supporter la Copyright © All rights reserved.
Failed to retrieve file