1. 12V DC SAL BR 50 mA LHF 400 mA Validating speed lt 25s FRR lt 1 FAR lt 0 0001 Operating Temperature 0 C 45 C Operating Humidity 20 80 Language English Simplified Chinese Traditional Chinese OEM Supply OEM Produce Size 82 L 35 W 180 H mm Function Description
2. If the finger is dry the user should rub Dry or dirty fingerprints his finger on his palm and than try to enroll and verify The finger should be clean while enrolling Sensor does not The user should place the finger recognize the firmly with enough pressure and presence of finger squarely on the sensor surface LL Access Options How to select the finger We recommend to use left or right index or middle finger Use fingerprints of good quality which does not have more wear and tear If the user s finger is thin and does not cover 80 of the sensor surface we recommend to use the thumb How to place the finger Place your finger firmly and touch the sensor surface so that it covers 80 of the area Do not remove the finger too fast and do not move the finger on the sensor surface Others However few users fingerprint quality is too poor to verify Please use ID amp fingerprint verification and the Match Threshold Levels can be reduced or use password verification 5 System Options Press the Menu then verify your identity So that the following screen appears Menu v gt User Manage Press Up or Down key to select Options Scroll down the menu and the following information will be displayed User Manage v gt Options System Opt gt Power Mne Power Mng gt Comm Opt LJ Access Options In the setup options there are
3. User Acc Opts 4 gt GRP TZ Define GRPTZ Define P Access Comb D Comb Lock Lock gt DSen Delav DSen Delav a gt Tcan Access Options has 7 main functions Time Zone Access Timings for a user for a week User Acc Opts Define various options like groups and time zone options for each user GRP TZ Define To create a group based on the time zones LL Access Options Access Comb Define different unlocking combinations for each group Lock Duration for which the lock needs to be kept open after the user is successfully verified 8 3 1 Brief Introduction to Access Options Access Options function is used to program the settings of registered user s based on their access rights Each user should be assigned a group and is assigned a time zone based on the access rights Users can be divided into a maximum of 5 groups and for each individual group a separate time zone can be defined Each individual user can belong a to maximum of three different groups The lock will be activated if the users access rights are satisfied from any of the three groups Conditions of a registered user can unlock the door are 1 The group that user belongs to should be in unlocking combination also this group can be in unlocking combination with other groups but it is required to unlock door together with them 2 Current unlocking time should be in any effective time zone in user time zone By default a new
4. User Verification Verification occurs when a user either enters an ID number or places a finger on the fingerprint sensor If the user is enrolled with fingerprint and or password than he need to enter the password as an alternative to finger 3 1 3 Match Threshold Levels The Match Threshold is a number that represents the degree to which a verification is performed to ensure that the user is the user who he claims to be The Match Threshold Levels establishes a balance between False Acceptance Rate FAR and False Rejection Rate FRR FAR measures how often a non authorized user is falsely recognized and granted access to the system FRR measures how often an enrolled and authorized user who should be granted access to the system is denied on the basis that the system did not recognize him You can set match threshold levels on a per user basis However for fingerprints which are facing difficulties in verification we recommend to use 1 1 matching i e enter his user ID than place the 33 LL Access Options finger for verification Raising the threshold increases security while lowering it increases throughput Based on the quality of the fingerprints of the users you need to strike a correct balance For users with worn or damaged fingers match threshold levels can and should be reduced Different installations have different requirements Table 1 1 Suggested Match Threshold Settings FRR FAR One to many One to
5. one High Low 25 Middle Middle 15 Low High 10 3 1 4 User ID Numbers Each fingerprint is assigned a User ID Number This ID number is used to call up the fingerprint template each time the verification is requested ID numbers can also be called up via the keypad or RF card 3 1 5 Authority status Levels ACT FP has four authority or status levels Users are people whose identity must be verified to have access to the door Enrollers are Users who are authorized to enroll new users or delete from the system Administrator can perform other operations except set advanced option and enroll administrator authority Supervisors are users who has access to all functions and can modify all the settings in the system Note Without Administrator and Supervisor enrolled in the LJ Access Options system the Enroller can add users If Supervisor is not enrolled in the system the Administrator can add him 3 1 6 Start up window Plug the power adaptors to the mains power supply or hit the Power button on the keypad and the following startup window appears on the ACT FP Welcome 0315 10 08 MON 3 2 How to place the finger Place the finger flat and in the center on the sensor Try to cover atleast 80 of the sensor area lt Do not place the finger in the following positions Upright Sideways LJ Access Options gt Note Please adopt the correct method for placing the finger for ve
6. the number of transactions reaches a set value a warning alarm will be sounded to clear the memory Recheck Minute This can be set to avoid record duplicate punches For eg If this value is set as 2 then it will not record the transaction of the same user ID within 2 minutes of the first punch 5 5 Access Options Select the Acc Opt menu and the following options will be displayed on the screen Access Options V P Define TZ Define TZ v P User Acc Opts User Acc Opts gt GRP TZ Define gt Access Comb LL Access Options Five main functions in Access Options are Time Zone Define Define the access timings for the day of the week User Access Options Assign the group to each user based on their access rights GRP TZ Define Assign the time zones to the group based on their access rights Access Comb is to define various unlock combinations every combination consists of different groups Lock Lock open duration time can be set with this option DSen Delay The time duration after which the door sensor should be activated For details of the operation please refer to the Access Options Operating Guide 5 6 Auto Test Select the auto test option and the following screen appears Auto Test v Run All Test v FLASH Tet gt LCD Test LCD Test s P Voice Test Voice Test gt FP Reader FP Reader gt Key Test Key Test gt RTC Test LL Access Options With this option we ca
7. user is assigned a group 1 and time zone 1 By default group 1 and time zone 1 have unlocking option set for all days of the week If the group of a user does not include in any grouping combination then that user can only record attendance but it will not activate the relay contacts to open the door LJ Access Options 8 3 2 Verification Flow of Access Options User places the fingerprint e User GRP in unlocking Comb Satisfy certain No unlocking gt Next GRP user combination Combine to unlock door Function Description 8 4 Function Description 8 4 1 Definition of Time zone Time zone is the minimum time zone unit of Access Options Whole system can define maximum 50 time zones 7 time regions i e one week can be set in each time zone Each time region is effective time zone in 24 hours of a day Each user can set maximum 3 time zones Relationships among these three time zones are OR It is effective as long as the time to verify can meet one of these three time zones Each time region format of time zone is HH MM HH MM i e the format is according to 24 hour mode and accurate to minute End time less than start time 23 57 23 56 represents all day forbidden End time larger than start time 00 00 23 59 represents effective in this region Effective time zone for user to unlock all day open 00 00 23 59 or end time larger than start time in time zone XW Note System defaults that time zone
8. ACT FP User Manual PRINT ELECTRONICS USA INC 505 8th Avenue 17th Floor Suite 1703 New York NY 10018 Tel 212 268 5020 Ext 202 Fax 212 268 4858 e mail support printelectronics com www printelectronics com Replication or Reproduction of this document or part of this document is strictly prohibited without prior approval of Print Electronics All the functions and uses are recommended for ACT FP products only Due to continuous upgrades and customization of the products we do not take any responsibility for any or part of the functions not present in the ACT FP which you purchased Design and Specifications are subject to change without notice All trademarks and copyrights are acknowledged Contents Contents Introduction Things to know Basic Concepts 3 1 Basic Concepts 3 1 1 User EnrollMent arni a ah 33 3 1 2 User Verification 3 1 3 Match Threshold Levels 3 1 4 User ID Numbers 3 1 5 Authority status Levels 3 1 6 Start up window 3 2 How to place the finger 4 Enrollment and Verification Procedures 4 1 Enrolling Users 4 1 1 Fingerprint Enrollment 4 1 2 Password Ensrollim nt ccccccccecceceesseseeseeseeneeeecnsenseeseeseens 39 4 1 3 Fingerprint amp Password 4 2 Testing an Enrollment 4 3 Enrolling a User with the Display Finger Option On 4 4 Verifying Your Identity 4 4 1 Fingerprint Verification 4 4 2 Password Verification 4 4 3 ID number amp Fingerprint 4 5 _ H
9. ain interface Select Options Press OK enter Select Acc Opts Press OK enter menu Press UP or Doen enter select DSen Delav display as follows Lock gt DSen Delav Press OK select number Press Up or Down key to modify DSen Delav 8 4 7 Dsen Mode Dsen Mode include three No NC None No No use door magnistor NC When the door is open the lock is open None When the door is closed the lock is closed Press MENU enter main interface Select Options press OK enter menu Select Acc Opts prsee OK enter menu DSen Mode display as follows Press OK select option press Up or Down key to change the state of Dsen Mode DSen Delav A p Dsen Mode NC DSen Delav A Dsen Mode None Function Description User capacity 500 1000 1500 Transaction capacity 30000 Verification mode 1 1or1 N Access Contro 50 TimeZone 5 Grouping 10 Access Comb X HEBAHA KAREDAD BRE mh FURS Se kel 1S DR Technical specifications Access Contro 50 TimeZone 5 Grouping 10 Access Comb X HSBAHA BARB MEAs ie RRS mh FURS Sees Electrocontrol Relay output 3A 12VDC SAW Ait Support zk attendance software Atl A 4A a A RA 4 h Communications Optional TCP IP RS485 RS232 Wiegand f H Wiegand26 output Optional keyboard and Display Wen 44 SRR BB Power
10. be seen that 123 is a combination 4 is a combination 24 is a combination 45 is a combination 15 is a combination Combination 1 when personnel of group 1 group 2 and group 3 are all on the scene and the time zone is effective in which at least one user in each group passes verification together then door can be unlocked Combination 2 only one of personnel belonged to group 4 is on the scene then door can be unlocked Combination 3 when personnel of group 2 and group 4 are all on the scene and the time zone is effective in which at least one user in each group passes verification together then door can be unlocked Combination 4 when personnel of group 4 and group 5 are all on the scene and the time zone is effective in which at least one user in each group passes verification together then door can be unlocked Combination 5 when personnel of group 1 and group 5 are all on the scene and the time zone is effective in which at least one user in each group passes verification together then door can be unlocked Function Description Note time zones that cannot pass verification lt User time zone does not select serial number of time zone lt Group time zone does not select serial number of time zone lt Time in which user passes verification does not include any time zone that is set by user lt Time zone is defined as forbidden xW Note If time zone that user sets is the time zone that cann
11. can be relocate into other group Select serial number of Time Zone already being set in group Time Zone New registered user default uses time zone of group 1 But after user resets the belonged group the user uses default time zone of correlative group So default time zone of each group should be defined first For details of use group time zone please refer to User Access Options XA Note time zone of system defaults that group 1 selects serial number 1 of time zone i e new registered user default can unlock door a Enter GRP 1 TZ Define and screen displays as follows GRP TZ Define a Function Description Press OK to enter GRP 1 Dflt TZ p TZ also en a TZ2 There are p 123 40 Define Relationships among these 3 Group 1 is effective in time zones of 1 8 and 40 and can also select other defined time zones b Enter GRP 2 Dflt TZ and screen displays as follows Setting of time zone of group 2 GRP TZ Define Group No Press OK to enter GRP 2 Dflt TZ p TZ1 ALAA A 0 and 36 and can also On the analogy of this time zones of each group can be defied according to practical requirements Whole system can define time zones of maximum 5 groups Function Description 8 4 3 User Acc Opts User Access Options is to process correlative setting according to user s requirements 1 Enter this menu to check certain user s Access Options status User Access Options in
12. clude belonged grouping setting use group time zone and user time zone Grouping divides registered users into several groups is easy and convenient to manage lt Use group time zone whether the user uses default time zone of belonged group lt V User time zone is user to set user s unlocking time and select serial number of time zone already being set Note relationships between use group time zone and user time zone Yes and No in Use Group Time zone only have impact on the following user time zone 1 If use group time zone is Yes then user time zone will automatically be assigned the value of serial number of time zone of belonged group group time zone should be set in advance 2 If User Time zone is changed then use group time zone automatically change to No Function Description Example of setting The following example is to set user 00001 and 00002 to group 1 and group 2 respectively A Enter setting interface of serial number 00001 and screen displays as follows User Acc Opts Enroll ID 00001 Press OK to enter setting menu of use group time zone Press UP and DOWN keys and select Yes Screen displays as follows User 00001 Opt P Belong to GRP Belong to GRP P Use GRP TZs Use GRP TZs p 12 TZ 1 p TZ 2 TZ 2 p TZ 3 User of serial number 00001 User s belonged grouping is 1 it uses time zone of group 1 serial numbe
13. d against that ID no Press OK the previous message continues to be displayed while the template is created If your identity cannot be verified you are prompted to try again And you must restart the verification procedure from step 3 4 1 2 Password Enrollment 1 Access the password enrollment option and press OK so that the screen ap New Enroll ESC OK 2 Press OK so that the following screen appears New Enroll Enroll ID 00002 LJ Access Options 3 Input the User ID from 1 to 65534 press OK so that the following screen appears New Enroll Input Pwd 4 Input the password and press OK so that the following screen appears New Enroll Pwd Affirm gt Note The password range is 1 to 5 5 Input the password again press OK so that the following screen appears 00002 P O00 Note 00002 P ESC The last letter P means user ID is enrolled with password Press OK and the previous message continues to be displayed while the template is created 4 1 3 Fingerprint amp Password Access the Fingerprint amp Password press OK so that the following screen appears New Enroll ESC OK 2 Press OK so that the following screen appears New Enroll Enroll ID 00003 3 Input the password from 1 to 65534 press OK so that the following screen appears 00003 0 Place Fingero 00000 4 If the enrollment is successful three times in a row the follo
14. e platen is designed to work under greasy or dirty conditions However do clean if the platen is obscured or if users report deteriorating performance See cleaning the Optical Platen below 2 Cleaning the Keypad and Display To clean the keypad and display use a soft paper tissue which should be slightly damp 3 Cleaning the Optical Platen Clean the optical platen as follows LJ Access Options 1 If dusty blow air on the platen to clean any dust particles 2 If the sensor is greasy wipe it with a mild window cleaner or other similar neutral detergent Warning Do not use any other cleaner or the platen may be damaged Be careful not to scratch the platen 8 Opts Guide 8 1 Product Features Can store upto 1500 templates and 15000 transactions Easy to configure access control functions Internal integrated single door controller Self contained doorbell option for visitors Red and Blue LED indication for acceptance and rejection of fingerprints Provision to connect to Alarm if the unit is tampered Wall mountable back plate for secured installation 26 bit Weigand standard output to interface with third party controllers LJ Access Options 8 2 Basic Concepts Basic concepts in Access Options function 8 3 Access Options Select the Access Options function from the main menu and the following screen appears Access Options WV gt Define TZ Define TZ P User Acc Opts
15. ectly uses group number and does not consider user verification sequence between each group For example 123 represents group 1 group 2 group 3 and at least one user in each group congregates and passes verification together then door can be unlocked 4 represents that after individual user in group 4 passes verification then door can be unlocked System can simultaneously define maximum 10 unlocking combinations It is required that only one of them passes verification XA Note Unlocking combination of system initial default setting is 1 i e new registered user default can unlock door Press MENU and enter main interface Select Options and press OK to enter setting menu Select Access Options and press OK to enter menu Select Unlocking Combination Definition to enter Unlocking Combination and screen displays as follows Access Comb gt Comb Function Description ooooo0o00000000000 Comb 9 gt Comb 10 When do not process setting yet i e factory default status system defaults that group 1 is unlocking combination 1 and others are null If do not want to allow all users to unlock door then set 10 unlocking combination all to null If only want to allow some groups to unlock door together then set these groups in unlocking combination definition 1 For example Access Comb gt Comb 1 Function Description From above combination setting it can
16. ints for Successful Enrollments 5 System Options 5 1 System Options 5 1 1 Date Time 5 1 2 Language 5 1 3 Format esna Aastha eae 47 User Guide 5 1 4 Advanced Options 5 2 Power Manager 5 3 Communication Options 5 4 Log Options 5 5 Access Options 5 6 Auto Test System Information Troubleshooting User Acc Opts Guide 8 1 Product Features 8 2 Basic Concepts 8 3 Access Options 8 3 1 Brief Introduction to Access Options 8 3 2 Verification Flow of Access Options 8 4 Function Description 8 4 1 Definition of Time zone 8 4 2 Definition of Grouping Function 8 4 3 User Acc Opts 8 4 4 Access Comb CAD MOCK i tected Uk BASES ROR ERP RINGS 54 8 4 6 DS N DIV ccc ccccecccccceccscesscnseeecscescesecssesecseesecnssescesseseens 55 8 4 7 Dsen Mode Technical specifications LL Access Options 1 Introduction In this chapter details of the commonly used terms and the functions of each key are explained 122 32LCD Optical sensor for finger placernents OK Confirm the current option MENU Access to Menu and configuration C Cancel your current operation 4 Scroll up Scroll down Power button BELL Door bell Number Numerical keys LJ Access Options 2 Things to know Please do not install ACT FP in direct sunlight as this may affect the performance of the fingerprint sensor This may result in false verifications of the fingerprints Try to avoid the ambient tempera
17. n conduct test on the different modules of the system This will enable you to find the cause of the problem is the unit is malfunctioning It tests the Memory LCD Fingerprint sensor keypad and clock During the course of test you should guarantee the stability of the power If the power fails during the test it can cause damage to the hardware and make it unusable 6 System Information From the Menu select the Sys Info press OK so that the following screen appears Sys Info v gt Tlear Cnt A User Cnt gt EP Cnt FP Cnt gt Att Att Log Admin Cnt Admin Cnt gt Pwd Usr Pwd Usr gt Super Logs Super Logs P Free Space Info Free Space Info amp P Dev Info LL Access Options It displays the number of users enrolled number of passwords enrolled fingerprints enrolled manager and log information on the screen You can see some other information like remainder log capacity in the memory the device capacity the default date machine number 7 Trouble shooting 1 Cleaning From time to time the optical platen the keypad and display window require cleaning Since working environments differ it is not possible to define when cleaning should be performed Following is guide Figure 7 1 Cleaning Schedule Item Cleaning Frequency Keypad and Cleaning when visibly dirty and hard to read display window See cleaning the keypad and display below Optical platen Do not over clean Th
18. of serial number 1 is all day open i e new registered user default can unlock door 1 Enter Define TZ and screen displays as follows Define TZ gt Time Zone No Press OK to enter setting of time zone 1 and screen displays as follows Def Time Zone 1 Vv gt Sun 00 00 23 59 Sun 00 00 23 5y p Mon 00 00 23 59 Mon 00 00 23 54 Tie 00 00 932 5 ma 0 00 97 3 5o LH Function Description Definition of time zone 1 above is all day open i e factory default status 2 For example Time zone can be redefined i e definition of time zone 1 is Saturday and Sunday are break and not allow to enter Working time of Monday to Friday allow to enter Working time 08 30 18 00 Setting is as follows Def Time Zone 1 vy Sun 23 57 23 56 Sun 23 57 23 5y pMon 08 30 18 00 Mon 08 30 18 04 plue 08 30 18 00 Function Description On analogy of this multi time zones can be defied according to practical requirements Whole system can define maximum 50 time zones 8 4 2 Definition of Grouping Function Grouping function can divide users into group and can also combine different groups into different unlocking combinations which are easy and convenient for grouping management of Access Options And all that the grouping function can combine many unlocking combinations System defines 5 groups group 1 group 2 group 3 group 4 and group 5 New registered user default belongs to group 1 but the user
19. ot pass verification When meet combination 2 above user who displays prompt of Invalid Time zone Access cannot unlock door but can record attendance If there is user in group 4 who can meet unlocking condition then combination 2 can unlock door When meet combination 1 3 4 and 5 above user who displays prompt of Invalid Time zone Access cannot unlock door but can record attendance 2 For example one bank treasury requires that 3 people are all on the scene to open the door of treasury Detailed settings are as follows These 3 people belong to group 2 group 4 and group 5 respectively and have the right to unlock door within the same time zone Select Group 1 and press OK to enter edit status Press digit keys to enter 245 Then press ESC to exit and save setting interface zaNote When combination 245 is defined then user cannot define 24 25 45 as combination 8 4 5 Lock System requires to set fingerprint scanner to control the time to open electronic lock Setting to O is close Close lock control function One quantity unit is 20ms maximum value can be set to 254 i e 5 08s Select this item and press OK to enter Options Then press digit keys to enter corresponding digits Finally press ESC to exit and save setting Function Description 8 4 6 DSen Delav DSen Delav Some segment time which begin after open door just begin alarm Press MENU enter m
20. our identity Note If this is the first enrollment in a new or empty system you will not be prompted for verification The following message appears on the display Menu y gt User Manage Press Up or Down key select the option you need gt User Manage Y Options gt Options A Sys Info Press OK to access the User Manager and the following options will be displayed Menu gt Enroll User LJ Access Options Press Up or Down key select what you need options gt Enroll User vy Enroll Admin Enroll Admin A Delete Press OK to access the User Enrollment and the following options will be displayed Enroll User VW gt Enroll FP Press Up or Down key select what you need options gt Enroll FP Enroll Pwd Enroll Pwd FP amp Pwd gt FP amp Pwd Reg FP ID 4 1 1 Fingerprint Enrollment 1 Select the Enroll Fingerprint option and press OK so that the following options will be displayed New Enroll ESC OK LJ Access Options 2 If you want to enter a different ID no than type that ID and press OK The ID number should be in the range of 1 to 65536 New Enroll Enroll ID 00001 3 Select the ID no and press OK so that the following screen will be displayed 00008 0 Place Finger 4 If the enrollment is successful three times in a row so that the following screen appears Enroll ID 00008 1 ESC OK Note 00008 1 The number 1 represents the first fingerprint enrolle
21. r of user time zone is serial number of group time zone User 00001 is effective in time zones of 1 8 and 48 Function Description Enter setting interface of serial number 00002 and screen displays as follows User Acc Opts a Enroll ID 00002 Press OK to enter If serial number of user time zone is 1 or 20 then use group time zone automatically change to No User 00002 Opt p Belong to GRP Belong to GRP gt UserGRP TZs UserGRP TZs gt TZ 1 TZ 1 p 122 TZ2 p 123 User of serial number 00002 User s belonged grouping is 2 it uses user time zone and does not use group time zone i e it is effective in time zones of 1 and 20 When user wants to use group time zone then select Yes In user time zone serial number of group time zone will be automatically assigned the value of serial number of group time zone Contrariwise if user wants to use user time zone just directly modify the serial number in user time zone and use group time zone will automatically change to No 50 Function Description 8 4 4 Access Comb Unlocking combination is the direct representation of controlling unlocking For example if user wants that all registered users cannot unlock then the user can set all 10 unlocking combinations to null Unlocking combination definition is to define different unlocking combinations and each combination is composed of different groups Unlocking combination dir
22. rification We are not responsible for malfunctioning of the unit due to improper placement of the finger 4 Enrollment and Verification Procedures This chapter describes how to enroll and verify users on the ACT FP The following topics are included Enrolling User Testing an Enrollment Enrolling a User with the Display Finger Option On Verifying Your Identity Hints for Successful Enrollments Note You must have Enroller Administrator or Supervisor status to enroll users For information on status levels see Authority Status Levels on 1 1 5 36 LJ Access Options 4 1 Enrolling Users The first enrollment in a new machine will have the capability of enrolling other users If you are the administrator of the system than you should enroll as admin with your finger There are three modes of enrollment fingerprint enrollment password enrollment and fingerprint amp password The type of enrollment to be selected depends on the environment and the quality of the fingerprints of the users Fingerprint enrollment should be used for good quality of fingerprints like a typical office environment Fingerprint amp Password should be used for few people who are enrolled successfully but verification is difficult Password enrollment should be used for users who cannot be enrolled nor verified To start the enrollment process identify yourself first press Menu enter your ID number or fingerprint and then verify y
23. s Options Reset Opts Restore all default settings Del Att Logs Clear all the transactions stored in the memory Clear all Data Delete all the fingerprint templates and transactions Clr Admin Pri Change the rights of the administrator to a normal user Show Score Display the score of the quality of the fingerprint match Match Threshold Levels For helping in selecting threshold level settings see Table 3 1 3 Only 1 to 1 Disable 1 N matching 1 1 Threshold Levels For selecting the right level please refer the table 3 1 3 below Image QIt The fingerprint clearance degree Table 3 1 3 FRR FAR One to many One to one Low 25 Middle 15 High 25 10 5 2 Power Manager Select the power setup menu and the screen shall display the following information Power Mng gt Shutdown No gt Power on No LJ Access Options There are various power modes which can be selected This may significantly increase the life of the machine and satisfy the various requirements of the users Shut down Turn off the power at pre defined time Power on Turn on the power at pre defined time Sleep Enable sleep mode at pre defined time Press any key to bring the unit out of sleep mode Idle and Idle Minute These two options are related to each other When you set idle time to 0 then the idle setup function is off When the idle time is not set to O unit is minute for example 1
24. six options system setup power setup communication setup record setup door lock function setup auto examination We will discuss each option in details 5 1 System Options The following are the list of options within the System Options System Opt gt Date Time Date Time V gt Language ENG Language S E Fmt YYYYMMDD Fmt YYYYMM Adv Option LJ Access Options 5 1 1 Date Time You can set the date and time using this option 2004 07 28 9 47 56 To change the date press Up and Down Key then input the correct date and time Press OK to save the changes 5 1 2 Language Select the desired language and press OK The default language is English Data Time v gt Language SCH 5 1 3 Format for Display of Date on the Main Screen Press UP or Down to select Fmt option Press OK and select the Fmt option Language S PFmt YYYMMDD There are four formats to choose fom YYYYMMDD YY MM DD YY MM DD YY MM DD LL Access Options 5 1 4 Advanced Options Select the Advanced Option Press OK so that the following screen appears Adv Option P Reset Opts Press UP Q wn kev a ele e desired option Reset Opts P Del Att Logs Del Att Logs gt Clear All Data Clear All Data gt Clr Admin Pri Clr Admin Pri gt Show Score Show Score gt Match Thr Match Thr gt Only 1 to 1 Only 1 to 1 p 1 1 Thr Each option is explained in details as follows LL Acces
25. then the system will go to sleep mode in 1 minute Setup On time Fun ESC OK LJ Access Options 5 3 Communication Options Select the communication menu so that the screen will display the following information Comm Opt nd gt Baud Rate BaudRate v 115200 Dev Num gt IP Addr IP Addr v gt Net Speed Net Speed _ 100M A Ethernet v RS232 RS232 RS485 RS485 a gt COMM Key Dev Num The number of the machine ranged from 1 255 This is also the site code if you are using the Weigand communication protocol Baud rate The communication speed with which the unit communicates with the computer There are three options 9600 38400 or 115200 IP address By default the IP is 192 168 1 201 You may set the address as per your network settings 51 LJ Access Options Network speed The default network speed is 10M F Ethernet Enable or disable the TCP IP mode of communication RS232 Enable of disable RS 232 mode of communication RS485 Enable of disable RS485 mode of communication COMM Key The default value is set to 0 zaWarning If you are using RS485 communication in an outdoor environment a lightening protection device must be installed to protect the circuit from voltage spikes 5 4 Log Options Select Log Opt and the following screen appears Log Opt v gt Alm SupperLog 10 Alm SupperLog v gt Alm AttLog 10 Alm AttLog A P ReCheck Min 0 Alarm Attendance Log When
26. ture to rise above 40 deg C where ACT FP is installed If the unit is installed we strongly recommend to cover the unit with a protective cover for trouble free operation 3 Basic Concepts 3 1 Basic Concepts This section explains and describes the functions and options of enrolling the users User Enrollment User Verification Match Threshold Levels User ID Numbers Authority Status Levels The two most important functions are user enrollment and user 32 LL Access Options verification 3 1 1 User Enrollment Enrollment is the process of associating an ID number to the user s finger s to create a template This template is stored in the memory of ACT FP for future verification During user verification the stored template is compared to the current fingerprint scan to confirm the user s identity The enrollment process takes approximately 2 4 seconds Up to ten fingers can be enrolled for the same ID number so the user may have more verification options Ideally we recommend enrolling two fingers of each hand so that in case of injury of one hand the user can use the finger of the other hand as a backup It is recommended to enroll left or right index finger and left middle or right middle fingers For users with extremely thin fingers we recommend to enroll the thumb For users whose fingers are difficult to enroll or cannot be enrolled we recommend to enroll the password along with fingerprint 3 1 2
27. ul it will say Thank you and following screen appears Enroll ID 00008 Verified If your identity cannot be verified you are prompted to try again and the following screen appears 42 LJ Access Options FP Verify Place Finger Agn After about 0 5 seconds the display returns to the main screen 4 4 2 Password Verification To verify a user enrolled with password enter the userID number so that the following screen appears Enroll ID 00003 ESC OK Press OK the following appears Enroll ID 00003 Input Pwd Input correct password and press OK so that the following screen appears Pwd Affirm Enroll ID 00003 If the password cannot be verified the following screen appears Pwd Affirm Error pwd 4 4 3 ID number amp Fingerprint To verify a user enrolled with fingerprint and password enter the userlD number so that the following screen appears Enroll ID 00003 ESC OK The user will be prompted to place the finger and following screen appears LJ Access Options FP Verify Please Move Finger If your identity is verified the following screen appears and thereafter the user will be prompted to enter his password Enroll ID 00003 Verified 4 5 Hints for Successful Enrollments If the fingerprint of the user is of good quality then the verification will be successful In order to improve the fingerprint verification quality we recommend the following suggestions
28. wing screen appears New Enroll Input Pwd 5 Input your password so that the following screen appears New Enroll Pwd Affirm 6 Input the password again and press OK so that the following screen appears 00003 1P Note 00003 1P ESC OK 1P means the User is enrolled with one fingerprint and password Press OK so that the previous message continues to be displayed while the template is created 4 2 Testing an Enrollment Ask the users to place their finger to perform a verification If the verification is successful we recommend to adopt Fingerprint enrollment If the verification is inconsistent we recommended to use Fingerprint amp Password LJ Access Options 4 3 Enrolling a User with the Display Finger Option On Press ESC after the user is enrolled so that the Display Finger Option can be turned On New Enroll Backup Enroll ESC OK Enroll ID 00003 gt Note Where system memory permits it is advisable to have at least two fingers enrolled for all users 4 4 Verifying Your Identity After all enrollments are done in ACT FP the reader is ready to be used for access control ACT FP has three modes of verification Fingerprint verification Password verification or Fingerprint and Password 4 4 1 Fingerprint Verification Place the finger on the sensor surface so that the following screen appears FP Verify Please Move Finger After about 1 second if the verification is successf