Contents
1. 19 a Can t find the IP address of the serial server after running upgrad exe 19 b Unable to open a serial 19 Cantreceive send data usse 0000000 19 d Forget the password previously 19 e LOUSY code 20 f The serial communication server is used as the dialing server and the connection is established normally But it can t be open by a PC using IE while inputting the IP in the address bar will do enne 20 g The serial communication server is used as a dialing server and the connection is established normally But it can t be open fully or at all when using IE for complicated pages or downloading of large 20 h Unsuccessful PPP 0 04 1 1 0 0 0 nnne 20 i Can t be connected as a 20 ACCESSO O anran 21 a Modification of IP 21 b Creation of virtual serial port essen eene 21 UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 2 22 Chapter 1 General data on UT 66XX series serial serve a Product introduction The UT 66XX series serial communication server also called te
2. Socket TCP socket information Information Active TCP Socket Active TCP socket information UDP Socket UDP socket information f Miscellaneous Save Configurations It s very important to save the settings Any modification to the WEB need to be saved before exiting the web page otherwise the settings will be restored Reboot Server Restart the server Chapter Five Troubleshooting of UT 66XX series serial serve a Can tfind the IP address of the serial server after running upgrad exe 1 First make sure that the physical connection is normal the network cable distinct crossover cable and straight through cable and power supply is connected Observe the power indicator the LAN indicator and the ACT this lamp is off when the 10M network is connected and it is only on when the 100M network is connected 2 Make sure that the network adapter is available and can communicate with other local hosts 3 Turn off any tools or software that would shield broadcast packets don t run the system integrated firewall 4 f after an abnormal disconnection such as power down during IP configuration through a browser no device can be found reconfigure IP through the console b Unable to open a serial port 1 Make sure the network status is normal and the server can be pinged through 2 Check operation status to find out if the port is occupied 3 If the port is occupied find out if the settings in COM PORT OVER TCP
3. 1 22 Instruction Manual the UT 66XX Series Serial Server Table of Contents Chapter 1 General data on UT 66XX series serial 4 NEM LOCC WAC GUC TO ss RR RU 4 eU IRR 4 c Application 006 t m 6 Chapter 2 Instruction on installation of UT 66XX series serial 7 a Instruction on software 2 0 00 0 7 D Descnpliion or 5 teer teeth 7 Definition of nennen nennen sese 8 Chapter echnical parameters of UT 66XX series serial 9 a Technical 9 D Prod ctConliguration Table 10 Chapter 4 Description of WEB operation of UT 66XX series serial server 11 ORV 11 b Serial Port Communication 11 UU UU T m 12 d Authority 18 NE quc ERU 18 REPE 19 Chapter 5 Troubleshooting of UT 66XX series serial
4. M a COM port 7 h E Device IP address 1921681247 7 Cancel Device Port Keep live Status Report Immediately v Shareable Port setting COM port eom Device IP address 1921681247 7 Lancel Device Port 7 Keep live 300 Status Report Immediately Shareable rz UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063
5. up click Yes to go to the next step 2 The Setup com port over TCP IP window pops up click Next to go to the next step UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 20 22 1 Setup COE port over ICP IP Welcome to the COM port over TCP IP Setup Wizard This will install COM port over driver your computer t is recommended that you close all other applications before continuing Click Next ta continue ar Cancel to exit Setup Cancel 3 In this window you will be noted about where the virtual serial port software is installed Click Next to go to the next step Setup CON port over ICP IP EL Select Destination Location Where should COM port over be installed d Setup will install port over TCP IP inta the following folder To continue click Mest IF vau would like to select a different folder click Browse Ab least 1 4 MB of ree disk space is required 4 The prompt indicates that the installation is to be started Click Install to go to the next step UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 21 22 1 Setup port over ICP IP Ready to Install Setup is now ready to begin installing COM port over your computer Click Install to continue with the installation ar click Back if vau want to review or change any settings Destinatio
6. DHCP Enabled Enables the automatic IP configuration DHCP CLIENT ID If the Ethernet is to be used as the DHCP client then this option is to be input to the CLIENT ID of the DHCP in hexadecimal format Primate DNS Server The primary DNS server Second DNS Server The secondary DNS server CONSOLE Timeout Console time out access the serial server via the console port Boot Host Extension option starting the host Boot File Extension option import files Submit Submit the above options of the serial ports must be submitted to complete the settings Server Menu Server Information Server Information H gt Serial Port Communication Settings server Name jUT 6601 Mode Server Position Route Table Ethernet IP Address 1192 168 1 247 adc Ethernet IP Mask 255 255 255 0 gt Authority Management Ethernet Mode auto Users f H DHCP Enabled no t gt System Stats DHCP CLIENT ID Reset Ports Save Configurations Default Gateway Reboot Server Primate DNS Server Second DNS Server CONSOLE Timeout 5 Advanced Settings b Serial Port Communication Settings Serial Port Communication Settings Port communication settings of the serial ports Baudrate Baudrate of the serial port should be consistent in value with the baudrate of the serial device connected Type of Connection Type of the serial port including 5232 485 422 Data Bits Data bits The default is 8 and the a
7. Connection to the terminal server through the web to perform the configuration by doing this the user can use the UT 66XX series serial server in work conveniently Supports software update function The UT 66XX series serial server supports free software update to protect the investment of the user Supports status monitoring Not only indicators are provided on the UT 66XX series serial server for the analysis of the working status of the server but also statistics of the input output data of each network port and serial port as well as various information are provided for the analysis of the user Supports MODEM connection The UT 66XX series serial server supports MODEM plug in out UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 4 22 Security features The UT 66XX series serial server adopts the following security schemes to ensure the safe use of the product by the user xx Allows setting a server administrator password where only the system administrator is allowed to manage the terminal server eliminating the arbitrary modification to the UT 66XX series serial server by unauthorized personnel Thus the security of the configuration of the UT 66XX series serial server is ensured xx Possible to limit the host name the port is about to login so host users without registration will not be able to access the server so the secure access to the server is ensured Since the UT 66XX series seri
8. Power Network 10 100M Network full half duplex indicator UT 6632 Power ONetwork 10 100M 9 Network full half duplex indicator UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 6 22 c Definition of pins 1 Definition of serial pins for UT 6601 PIN RS 232 RS 485 RS 485 RS 422 HALF FULL Male DTR RJ45 RS 232 RS 485 RS 485 RS 422 HALF FULL 4 Definition of the UT 6616 6632 serial pins RS 232 RS 485 RS 485 FULL RS 422 HALF DATA pee Hee UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 7 22 E35 E cae 6 GND GND GND 6 GND ee T Chapter Three echnical parameters of UT 66XX series serial serve a Technical parameters Product model UT 6601 UT 6602 UT 6604 UT 6608 UT 6616 UT 6632 Number of serial a 32bits 100MHZ 50 460800bps Parity bits Nove Odd Even Mark Space Data bits 5 6 7 8 inici KONKOFF DB9 termin Protection 15KV lightning protection RS232 DCD RxD TxD DTR GND DSR RTS CTS RS422 TXD RXD TXD RXD GND Serial port RS485 Datat Data Lue 10 100M self adaptive support manual configuration Protection 2KV built in electromagnetic insulation ARP IP ICMP UDP PPP HTTP TELNET DNS DHCP PAP CHAP Virtual COM Windows NT 2000 XP Operating Temperatur 10 C 60 C e Working 5 95 humidity S
9. IP are correct through realport 4 Delete the corresponding COM port in the registry and remap c Can treceive send data 1 Make sure that the serial port can be opened normally 2 Find out if the TX value in System Stats Network Interface Information is increased If not check the connection between the serail port and the upper end network if TX is increased but the bottom serial port device dosen t receive check the cable Find out if the RX value in System Stats gt Network Interface Information is increased If not check the connection cable if yes check the connection between the serail port and the upper end network d Forget the password previously set 1 Press the reset button and hold for 3 s and then release the password will be eliminated temporarily UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 18 22 However the password will be recovered up the reboot after power down e Lousy code received sent 1 Make sure the cable connection is correct Specially problem of parallel cables should be noticed for our 485 devices 2 Check if the cable length exceeds the standard distance and the cable quality increasing the transceiver or the optical shutter is also applicable 3 Make sure the baudrate set matches with the bottom end device 4 Find out if it is possible to receive normal data using network or serial port commissioning assistant without upper end
10. by the terminal device to login to the Linux Unix host where each serial port supports up to 8 virtual displays All the displays support both the Telnet or Fixtty login and can choose to login a different host or the same host Allows communication with different hosts using the same terminal enabling the single user single terminal and multi mission operation The Fixedtty drive is provided for SCO Unix Linux Unixware under fixed port mode Fixtty No extra configuration work is required on the host except the installation of the drive program All the configuration is done on the terminal server through this way the cleaness of the host system is ensured and the operation of the terminal server won t be affected by other accidental actions In addition any name started with tty can be assigned to each login terminal by the user under the fixed port mode which is more convenient for management and easier for troubleshooting Supports PPP serial mode All the ports of the UT 66XX series serial server support the PPP protocol and can be used other as a PPP server end or as a client end after configuration Features routing function Allows configuration of multiple static routes inside the server Supports DNS for domain service Allows query of the required IP address for analysis when connecting a machine Supports ARP The UT 66XX series serial server supports the standard ARP protocol Parameters of configuration of terminal server
11. it is If means that the server will change an ENTER received from a serial port to a NEW LINE and then send it to the Ethernet cr If means that the server will change an ENTER received from a serial port to an ENTER a NEW LINE and then send them to the Ethernet LF As There are four parameters none cr If and cr lf none means that the server will not send an received from a serial port to the Ethernet cr means that the server will send an ENTER received from a serial port to the Ethernet just as it is If means that the server will change an ENTER received from a serial port to a NEW LINE and then send it to the Ethernet cr If means that the server will change an ENTER received from a serial port to an ENTER and a NEW LINE and then send them to the Ethernet Port 1 Mode Setting Communication Mode Line printer daemon Sequeue Name CR AS cr v LF 5 If w d Authority Management Secure Setting Security settings IP Access Limit Table List of IP access limit MAC Access Limit List of MAC access limit Table e System Status System Information System information Network Interface Network interface information Information Active Routing Active routing information Serial Port Serial ports information ARP Address Map ARP address mapinformation UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 17 22
12. software If can the problem might be something with the packing mechanism set the length and waiting time for the packing Serial Port Communication Settings Advanced Setting f The serial communication server is used as the dialing server and the connection is established normally But it can t be open by a PC using IE while inputting the IP in the address bar will do 1 Whether or not the Allocate DNS server in Specific parameters of PPP daemon of the serial communication server is Yes and the DNS set in Server is valid g The serial communication server is used as a dialing server and the connection is established normally But it can t be open fully or at all when using IE for complicated pages or downloading of large files 1 Check Serial ports in the serial communication settings to make sure that Flow control is consistent with the flow control of the MODEM Typically the flow control of the MODEM is achieved through rts cts hardware flow control 2 DCE rate for negotiation between MODEMS is too low redial h Unsuccessful PPP connection 1 Enter into the serial communication server configuration open Serial ports in Statistics and find out if the DCD status is 1 i e if the serial DCD signal of the serial communication server is high If not the serial communication server will not start PPP 2 Make sure the authentication modes of the client end and the server end are consistent an
13. Mode MODEM configuration This option has three parameters none in and out none MODEM control is invalid is waiting for dial in out MODEM dials out according to the setting of Telephone numbers Dynamic Dial Dynamic dialing There are two options no means that the server will only dial the number provided in Telephone number 1 when MODEM mode is out yes means that when MODEM mode is out the server will dial the number provided in Telephone number 1 at first If it can t be connected the number in Telephone number 2 Telephone number 3 and Telephone number 4 will be dialed sequentially until it is connected or the handshaking with the counterpart MODEM is successful MODEM Init The Modem initialization command Command 9955 MODEMDial The Modem dialing command Command 9955 TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 14 22 Server Menu Port 1 Mode Setting Server Information AME gt Serial Port Communication Settings Communication Mode Multi screens TTY v El gt Mode Screens wm Term Type vt100 Porti Auto Connect Logoff Route Table Prompt yes Host Table MODEM Mode none Dynami
14. Setting Server Information H gt Serial Port Communication Settings Communication Mode PPP daemon El gt Mode Authentication none Peer IP Address Porti Local IP Address Local Mask Route Table Allocate DNS no Freetime Host Table JE Modem Init Modem Dial gt Authority Management Nese CallBack no CallBack Phone H gt System Stats CallBack Mode local Reset Ports Save Configurations Reboot Server Line printer daemon Printer mode UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 16 22 It is used to connect a printer and to use the serial server as the printing server Remote printing is possible through connecting a printer on a serial or parallel port connected to a device with large number of ports to the server Communication Operation mode Mode Sequeue Name Sequence name Begin Sequeue Begin printing sequence The string sent by the server to the printer to initialize the printer pe before printing the main text End Sequeue End printing sequence The string sent by the server to the printer after the printing of the main text is finished CR As There are four parameters none cr If and cr lf none means that the server will not send an received from a serial port to the Ethernet cr means that the server will send an ENTER received from a serial port to the Ethernet just as
15. a serial port to the Ethernet just as it is If means that the server will change an ENTER received from a serial port to a NEW LINE and then send it to the Ethernet cr If means that the server will change an ENTER received from a serial port to an ENTER a NEW LINE and then send them to the Ethernet LF As There are four parameters none cr If and cr lf none means that the server will not send an received from a serial port to the Ethernet cr means that the server will send an ENTER received from a serial port to the Ethernet just as it is If means that the server will change an ENTER received from a serial port to a NEW LINE and then send it to the Ethernet cr If means that the server will change an ENTER received from a serial port to an ENTER a NEW LINE and then send them to the Ethernet Number of hosts connected to the device up to six Authentication It is possible that the server send a request for authentication when connected the connection will be cancelled if the user s name and the password are incorrect This UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 12 22 configuration option has two parameters none and local Vote f oca is selected for the authentication the users should be added correspondingly and It 1s possible fo set the operation authority of the users to the serial ports if no user
16. al server is connected to network during operation the server is PPP certified support PAP and CHAP certification to ensure the security of the server during the network access xx Possible to pose limits to the hosts or network segments allowed to access the server the unauthorized objects not registered in the hosts list and the network segment will not be able to pass the network access server The ex factory IP address of the UT 66XX series serial server is 192 168 1 125 and the subnet mask is 255 255 255 0 c Application mode 1 Virtual serial mode M s UT 66X X 2 Point to point mode UT 66X X UT 66X X UT 66X X UU rien da UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 5 22 4 Multi host mode up to 6 hosts UT 66X X Chapter Two Instruction on installation of UT 66XX series serial serve a Instruction on software installation 1 IP address search and software modification See the annexes for details 2 Virtual serial software See the annexes for details b Description of LED indicators Sequence First Second Third Fourth Fifth UT 6601 e Power 10 100M Network connection UT 6602 10 100M Network ePower e 1 indicator for 2 indicators connection serial port for serial port status statuses UT 6604 10 100M Network ePower e UT 6608 10 100M Network ePower mm o UT 6616
17. c Dial ino v Authority Management 7 MODEM Init Command EN MODEM Dial Command ond Phone 1 Phone Number2 Reset Ports Phone Number3 l 21 Phone Number4 Save Configurations Callback no Callback Phone Reboot Server Screen Mode Host Switch Code Ack Code Print Init Code 1 2 telnet EN uM telnet w 5 telnet v 6 telnet Screen Username Script Username Password Script Password 1 gin uM ord 2 gin ord PPP dialout In this mode each serial port of the server can be used as the dial in out end of the PPP server it supports applications of remote dialing access Communication Operation mode Peer IP The IP address of the peer Used as the IP address of the peer serial port after the connection between the PPP client end and PPP server end is successful This IP address is optional and can be gained through the negotiation with the PPP server end Local IP The local IP address Used as the IP address of the serial port of the server after the connection between the PPP client end and PPP server end is successful This IP address is optional and can be assigned by the PPP server end Request DNS Request for the DNS server Whether or not request the IP address of the domain server 5 during the connection to the server end Yes for request No for not request Username The user name to be dial
18. ctual value should be consistent with the device connected Stop Bits Stop bits The default is 8 and the actual value should be consistent with the device connected Parity bits Including Nove Even Odd Mark and Space The default is N and the actual UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 10 22 value should be consistent with the device connected Flow Control Flow control FIFO First in first out enabled for default Lock Locking configuration possible to lock the configuration of the port for the convenient repeated setting in future days C M9 8 8 pay DTR ON DTR is a hardware based control mode of flow control where you can decide if it is LN necessary to set a data terminal ready signal for you application Keepalive Keepalive time configure the keepalive time of the ports of the terminal server the range is between 0 100005 0 for no keepalive work Baud Adjust Fine adjustment of the baudrate Advanced Setting Extension options Submit Submit to complete the setting after configuration of the above options you need to click on the submit button and then click on Reset ports select port1 and click on the Submit button to submit Apply to all ports Apply to all ports this option can be checked if all ports are of the same settings Server Menu Port 1 Set
19. d the user name and the password established are matched i Can t be connected as a TCP server 1 Make sure that there is no other PC connected to the corresponding port of the serial communication server To do this enter into Statistics of the serial communication server and view Active TCP information 2 If Authentication in Specific parameters is none If the problem remains unsolved please contact the manufacturer UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 19 22 Chapter Six Accessories a Modification of IP address After the device is connected start the attached software upgrade as show in the figure below select Server search all devices or click on the red circle in the following figure and then you can view addresses and basic information of all the UT 66XX series devices connected to the network Click and select a device change the IP address through selecting Tool Temporary change ip address The IP address should be in the same network segment of the switch connected to the serial server for example if the IP of the switch is 192 168 1 1 and then the IP address of the server should be 192 168 1 XXX Fireware upgrade utility Tools Help MAC Address UT 6601 reese 00 0 45 01 60 12 b Creation of virtual serial port 1 Run the virtual serial port setup file setup exe the Setup window will
20. de PPP dialout A cl Mode Peer IP Local IP Port1 Local Mask Request DNS no QE que Username Password Host Table CHAP Needed ino Y Free Time Authority Management espe Modem Init Cmd Modem Dial Cmd System Stats Phone Numberi Phone Number2 Reset Ports Phone Number3 Phone Number4 Save Configurations CallBack CallBack Phone Reboot Server eu Dynamic Dial ino PPP daemon In this mode each serial port of the server can be used as the dial in out end of the PPP server it supports applications of remote dialing access Communication Operation mode Mode Authentication Authentication mode Identity authentication is required when accepting the connection from the client end There are three options none pap and chap None represents for no authentication Peer Address Peer IP address the IP address assigned to the client end Local IP Address Local IP address Local IP Mask Subnet mask Allocate DNS Allocation of DNS server Whether or not allocate the IP address of the domain server to the client end during the connection with the client end Yes for request No for not request Freetime Allowed idle time The server will disconnect automatically if there is no data transmission in the time period set after the connection is established The value range of the option is between 0 10000 min Entering or nothing means automatic disconnection is disabled Server Menu Port 1 Mode
21. ed out Enter the user name here if authentication is required by the server end to be connected Password The password to be dialed out Enter the password here if authentication is required by the server end to be connected CHAP Needed CHAP is one of the PPP certified protocols Selecting yes means that this protocol must be used during connection selecting no means that it is optional Free Time Allowed idle time The server will disconnect automatically if there is no data transmission in the time period set after the connection is established The value range of the option is between 0 10000 min Entering or nothing means automatic disconnection is disabled Modem Init Cmd The Modem initialization command To initial the MODEM connected to this serial port typically at is used for the client end Modem Dial Cmd The Modem dialing command What dialing mode the MODEM will use audio or pulse Type for audio dialing which is the most case in practical applications and atdp for pulse dialing Phone Number2 Dialing out number 2 Phone Number3 Dialing out number 3 UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 15 22 Phone Number4 Dialing out number 4 CallBack To callback CallBack Phone The callback telephone number Dynamic Dial Dynamic dialing Server Menu Port 1 Mode Setting Server Information H gt Serial Port Communication Settings Communication Mo
22. ls added the authentication set is Invalid which means that the connection will be permitted to be established even the Input user and password dont exist Auth Prompt If this option is set to yes a login hint will show up when connecting the server Login and Password SERVER First Server priority status Used as a TCP client The IP address pointing to the server end The port number pointing to the server end Connect Issuing a connect includes four situations always char dcdon and dsron always means that the server starts a connection at power up and reconnects immediately if the connection is broken char means that the server starts a connection as soon as the corresponding port receives the data dcdon means that the server starts a connection when DCD of the corresponding serial RS 232 port is set to a high value dsron means that the server starts a connection when DSR of the corresponding serial RS 232 port is set to a high value Disconnect Issuing a disconnect includes four situations none dcdoff dsroff and break none means that the server will never try to disconnect dcdoff means that the server disconnect when DCD of the corresponding serial RS 232 port is set to a lower value from a higher value dsroff means that the server disconnect when DSR of the corresponding serial RS 232 port is set to a lower value from a higher value break means that the server disconnect
23. n location C Program Files NSEH Cancel 5 If this window appears it means that the virtual serial port software has been installed on your computer normally Click Finish to complete the installation Setup port over ICP IP Completing the COM port over TCP IP Setup Wizard Setup has finished installing COM port over on pour computer Click Finish to exit Setup C Open the virtual serial port software Run the virtual serial port software through Start menu control panel COM port over TCP IP as shown below Select the required COM port and click on a new window named Port setting will pop up enter the IP address of the serial server such as 192 168 1 247 Enter 1 for Device port note that based on what port the multi port serial server is entered e g enter 5 for the fifth port of an 8 port serial server and you can also create 8 serial ports at the same time when you just enter 1 8 KeepAlive is the active time of the port and the typical setting is 300s Status Report is typically set to immediately for an instant connection Then click OK Configure other COM ports in the same way It s very important to press the Save button after finishing the required COM ports before you can use the virtual COM ports UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 22 22 Port setting
24. nnect the various serial devices including terminals Modems barcode machines cash receivers ISDNs terminal adapters serial printers and PCs etc able to support the remote control function yx Reset key is provided for the force reset after a system crash xx A 10 10M self adaptive Ethernet port with possibility of manual configuration yx Complete signal is provided for each serial port including DCD RXD TXD DSR TRS CTS GND yx Powerful whole performance with the embedded 100M 32bit CPU and 8M RAM UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 3 22 Independent indicator for each network port and serial port for convenient indication of working status Supported protocols include ARP IP ICMP UDP TCP PPP HTTP TELNET DNS DHCP PAP CHAP etc Supports extended serial port mode under Windows Complete extended serial port com drive based on the Windows platform and simple and easy to use management programs under the Windows platform Up to 1024 serial ports under the WindowsNT Windows2000 WindowsXP with each serial port of the UT 66XX series serial server to be mapped as the local COM port of the Windows host PC Operation of these ports is similar to operation of the local COM ports on the host plus any existing software or communication module of the original device can be used directly without any change Supports the UNIX host login mode The present mode is used
25. o protocols telnet and rtelnet Telnet doesn t need any drive program but the terminal name it receives when login to the system is not fixed rtelnet uses drive program to login to the same terminal for each time thus the terminal name is fixed Communication Operation mode Mode Screens Number of screens each serial port supports up to 6 screens UT 66XX supports multi screen switching Term Type Terminal type Here the user can enter the type of the terminal simulation to adapt to the handling of special characters Auto Connect Automatic connection There are two options cr and auto cr will connect to the host when the ENTER button on the terminal is pressed and auto will connect to the host at power up Logoff Disconnection conditions there are four options none dcdoff dsroff and break none means that the server will never try to disconnect dcdoff means that the server disconnect when DCD of the corresponding serial RS 232 port is set to a lower value from a higher value dsroff means that the server disconnect when DSR of the corresponding serial RS 232 port is set to a lower value from a higher value break means that the server disconnect when the corresponding serial RS 232 port receives a break message Prompt Prompt message The actions and status of the current connection will be displayed on the terminal when connection is established between the server and the UNIX host MODEM
26. rminal server or serial server is a converter between the asynchronous serial port RS232 422 485 and Ethernet which is an independent intelligent device with a CPU an embedded OS and a complete TCP IP protocol stack The device is used for transparent and bidirectional data transmission between the RS232 422 485 and Ethernet and for enabling the instant connection to the network of the RS232 422 485 serial device Product features Supports both dynamic IP DHCP and static IP supports both gateway and proxy server able to transmit data through the Internet Provides transparent and bidirectional data transmission able to convert serial port to TCP IP without any additional modification to the existing system made by the user Internally integrated protocols ARP IP TCP HTTP ICMP SOCKET UDP Full English interface for all programs wizards are easy to use even for new computer users UT 66XX series serial server includes the following models UT 6601 single port UT 6602 dual port UT 6604 quad port serial server serial server serial server UT 6608 8 port serial UT 6616 16 port serial UT 6632 32 port serial server server server b Main features yx English menus of configuration interface with the various operation modes able to meet the application demand of different industries xx Virtual COM drive software for Windows xx Flexible and reasonable Fixedtty working scheme under UNIX yw 1 2 4 8 16 or 32 serial ports to co
27. t 1 Mode Setting Server Information _ gt Serial Port Communication Settings Communication Mode TCP realport 5 El gt Mode Sessions 1 Authentication Porti Route Table Host Table H gt Authority Management Users H gt System Stats Reset Ports Save Configurations Reboot Server Udp realport UDP virtual serial mode Communication Oparetion mode option Mode Host Address Host address Submit the above options of the serial ports must be submitted to complete the settings Apply to all ports Apply to all ports this option can be checked if all ports are of the same settings Port 1 Mode Setting Mode UDF Host 4ddress TCP IP socket WINSOK mode Communication Working mode option Mode TCP Data Mode There are two parameters for the TCP data mode raw and telnet the first is for fully transparent transmission and the second means that the socket data is in accordance with TELNET and RFC2217 standard Control code is added to the data received by the server from the serial ports and then sent to other nodes in the Ethernet through socket Local Port Port number default as 1001 1002 CR As There are four parameters none cr If and cr lf none means that the server will not send an received from a serial port to the Ethernet cr means that the server will send an ENTER received from
28. tings Server Information __ l I gt Serial Port Communication Settings Baudrate 9600 v Type of Connection RS232 v Porti Data Bits Stop Bits 1 gt Mode Parity n a Flow Control 4 Route Table amp dvanced Setting Host Table gt Authority Management Submit Users System Stats Reset Ports Save Configurations Reboot Server c Working mode TCP realport TCP IP virtual serial mode TCP realport works in Windows environment to map ports of a serial server as virtual COM ports of the local host through drive program enabling the COM based upper end software to use the serial ports just like real local COM ports without any modification of the software The drive program supports an extension of COM1024 for the most Moreover each independent port supports multiple sessions up to 6 connections which makes the monitoring of the serial devices more flexible and more convenient In addition the multiple connections resource can be used as a connection backup Communication Operation mode option Mode Number of hosts connected to the device up to six Authentication Authentication UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 11 22 Submit the above options of the serial ports must be submitted to complete the settings Apply to all ports Apply to all ports this option can be checked if all ports are of the same settings Server Menu Por
29. torage 20 85 temperature UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 8 22 Storage 5 95 humidity Certification FCC CE Power supply DC 5V 1A AC 220V Metal housing 97x65x0 87i 113 77 0 9 Standard 19 inch 1U of 3 Dimensions 160x90x1 18in n lin height b Product Configuration Table for set of equipment Configuration Power Product manual Serial server Softwar RJ45 to DB9 male supply and warranty host e adapter UT 6602 2 channels of 1 DC5V 1A 1 1 RS232 UT 6602 2 channels of RS485 422 UT 6604 3 in 1 UT 6608 3 in 1 UT 6616 16 channels of RS485 422 UT 6632 32 channels of RS232 UT 6632 32 channels of RS485 422 AC220V cable AC220V 1 1 1 cable AC220V cable UT 6616 16 channels of AC220V RS232 cable UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 9 22 Chapter Four Description of WEB operation of UT 66XX series serial serve a Server Menu Server Menu Server Information setting of server information Server Position Serial server position can be user defined Such as name of the installation position for convenient maintenance Ethernet IP Address Serial server internal IP address Ethernet IP Mask Internal network subnet mask Ethernet Mode Network rate can be manually set to 10M or 100M the default option is auto detecting the network rate automatically
30. when the corresponding serial RS 232 port receives a break message Freetime Idle time To set the idle time before automatic disconnection the server will disconnect if there is no data transmission in the time period in second set If the value is set to 0 the server will never try to disconnect no matter how long the idle time is Server Menu Port 1 Mode Setting Server Information H D Serial Port Communication Settings Communication Mode TCP UDP Socket M Eh Made TCP Data Mode raw Local Port 110001 Porti CR As ec LF As Route Table Sessions 1 Strip NULL Host Table Authentication none Auth Prompt H gt Authority Management a EE f SERVER First no Users A Hi Session Protocol Peer Host Peer Port Connect Disconnect Freetime gt System Stats FU 1 34 ru z 34 1 TCP server always none Reset Ports Ex 2 z v v v Save Configurations 2 TCP server always r Reboot Server 3 TCP server always none 4 TCP server m o always v none 5 TCP server always 5 TCP server v always w none Multi screens TTY The server can use this mode as a char terminal which is common in financial industry This mode UTEK TECHNOLOGY ASIA CO Ltd http www szutek com 0755 27886063 13 22 supports tw