Home

7 - Technical Break Fibaro.com

image

Contents

1. OPERATING MANUAL RELAY SWITCH FGS211 v1 4 v1 7 Remotely Controlled Relay Switch of FIBARO system is designed to operate in a wall switch box wall socket box or in locations where the control of an electric device up to 3kW is needed It is also possible to send a signal to any system that is to be integrated with Fibaro system Specifications 110 230 V AC 10 50 60Hz 24 60V DC 10 Power supply Rated load current for AC 16A 230V 50 60Hz output Rated load current for DC 16A 30V output Output circuit power 3 kW resistive load 230V Comply with EU standards EN 55015 EN 60669 2 1 Circuit temperature limits 105 C Operational temperature 0 40 C For installation in boxes 50mm Radio protocol Z Wave 868 4 MHz for EU 908 4 MHz for US 921 4 MHz for AUS NZ BRA Radio Frequency Range up to 50 m outdoors up to 30 m indoors depending on building materials Dimensions H x W x D 15 x 42 x 38 mm Electricity consumption lt 0 8W In case of load other than resistive pay attention to the value of cos and if necessary apply load lower than the rated load Technical Information e Controlled by FIBARO system devices or any Z Wave controller e Microprocessor control e Executive elements relays e The device may be operated by mono stable and _ bi stable push buttons DANGER Danger of electrocution All works on the device may be performed only by a qualified and licensed electr
2. days from the date of delivering the Device to AGS The guarantee period shall be extended by the time in which the Device was kept by AGS 9 The faulty device shall be provided by the Customer with complete standard equipment and documents proving its purchase 10 Parts replaced under the guarantee are the property of the Manufacturer The guarantee for all parts replaced in the guarantee process shall be equal to the guarantee period of the original device The guarantee period of the replaced part shall not be extended 11 Costs of delivering the faulty device shall be borne by the Customer For unjustified service calls the Service may charge the Customer with travel expenses and handling costs related to the case 12 AGS shall not accept a complaint claim only when e the Device was misused or the manual was not observed e the Device was provided by the Customer incomplete without accessories or nameplate e it was determined that the fault was caused by other reasons than a material or manufacturing defect of the Device e the guarantee document is not valid or there is no proof of purchase 13 The Manufacturer shall not be liable for damages to property caused by defective device The Manufacturer shall not be liable for indirect incidental special consequential or punitive damages or for any damages including inter alia loss of profits savings data loss of benefits claims by third parties and any property damag
3. electrical box 4 Arrange the antenna tips are presented below diagrams single switch SWITCH single switch option with an alternative power supply for the load alternative power supply SWITCH double switch SWITCH double switch option with an alternative power supply for the load alternative power supply SWITCH Fig 1 Circuit diagrams for Fibaro Switch NOTES FOR THE DIAGRAM N terminal for neutral lead L terminal for live lead input terminal for load power supply O output terminal of the load S2 terminal for key no 2 S1 terminal for key no 1 has the option of entering the device in learning mode B service button used to add or remove a device from the system Note It is possible to supply the load with voltage other than the power supply to Fibaro switch e g different phase or voltage or even DC Detailed data are contained in specifications and diagrams of Figure 1 Durability of the device depends on applied load For resistive load light bulbs etc and 16A current the durability exceeds 200 000 switches For inductive load e g fluorescent lamp with cos 0 6 the flowing current should be limited to approx 12A to ensure reliable operation of the device for similar long period TIPS FOR ARRANGING THE ANTENNA Locate the antenna as far from metal elements as possible c
4. mains voltage to the Switch 3 Controlling Fibaro Switch by mono stable or bi stable switches mono stable switch after releasing the push button a spring automatically pushes back and disconnects the button Turning on off circuit 1 or 2 briefly press the push button corresponding to a chosen circuit see diagram bi stable switch operates as a two position switch it has no spring that would push back the device after releasing manual pressure Turning on off the circuit change the position of selected push button from the current position 4 Controlling Fibaro Switch using a command ALL ON ALL OFF Fibaro Switch responds to commands ALL ON ALL OFF that may be sent by the controller ALL ON ALL OFF commands are usually implemented in Z Wave remote control By default Fibaro Switch accepts both active commands ALL ON and ALL OFF Settings may be changed by entering an appropriate value into configuration register no 1 see configuration 5 Controlling Fibaro Switch using Home Center controller After adding Fibaro Switch to the network it will be represented in Home Center by the following icon a By default FGS211 device has a second hidden icon It represents the second virtual channel of the device triggered by the second key The user may add the association to this channel or trigger a scene Small lamp Fig 2 Icon of Fibaro Switch shown by Home Center controller Turning on off the
5. afety of the FIBARO system transmission is comparable to the safety of transmission in data bus wired systems FIBARO operates in the free band for data transmission The frequency depends on radio regulations in individual country Each FIBARO network has its own unique network identification number home ID which is why it is possible to co operate two or more independent systems in a single building without any interference Although Z Wave is quite new technology it has already become recognizable and officially binding standard similarly to Wi Fi Many manufacturers in various industries offer solutions based on Z Wave technology guaranteeing their compatibility This means that the system is open and it may be extended in the future Find more information at www fibaro com FIBARO generates a dynamic network structure After FIBARO system is switched on the location of its individual components is automatically updated in real time through status confirmation signals received from devices operating in a mesh network The In Wall Relay Switch is hereinafter referred to as Fibaro Switch It is designed to switch on off devices connected to its terminals using radio waves controllers and a push button directly connected ll Assembling Fibaro Switch Danger of electrocution 1 Before installation ensure that the voltage supply is disconnected 2 Connect Fibaro switch as shown on the diagram 3 Place the switch in the
6. commercial offer the Manufacturer may replace it with a different device having technical parameters similar to the faulty one Such activity shall be considered as fulfilling the obligations of the Manufacturer The Manufacturer shall not refund money paid for the device 5 The holder of a valid guarantee shall submit a guarantee claim through the guarantee service Remember before you submit a guarantee claim contact our technical support using telephone or e mail More than 50 of operational problems is resolved remotely saving time and money spent to initiating guarantee procedure If remote support is insufficient the Customer shall fill the guarantee claim form using our website www fibargroup com in order to obtain claim authorization When the guarantee claim form is submitted correctly the Customer shall receive the claim confirmation with an unique number Return Merchandise Authorization RMA 6 The claim may be also submitted by telephone In this case the call is recorded and the Customer shall be informed about it by a consultant before submitting the claim Immediately after submitting the claim the consultant shall provide the Customer with the claim number RMA number 7 When the guarantee claim form is submitted correctly a representative of the Authorised Guarantee Service hereinafter as AGS shall contact the Customer 8 Defects revealed within the guarantee period shall be removed not later than 30
7. device connected to Fibaro Switch is performed by pressing ON OFF icon IV Association Association enables Fibaro Switch to directly control a device included in Z Wave network e g Dimmer Switch ON OFF Roller Shutter or scene scene may be controlled only through the Home Center controller WARNING Association ensures direct transfer of control commands between devices and is performed without participation of the main controller Fibaro Switch provides association of three groups 1st group is assigned to key no 1 2nd group is assigned to key no 2 3rd group reports state of devices Only one device can be associated to this group Fibaro Switch enables user to control up to 16 normal devices and 7 MultiChannel devices in group no 1 and no 2 group no 3 has only one field The first field in each group is reserved for the network controller It is recommended to use up to 10 devices as the time required by the device to send a command to each associated device may be quite long To add an association using the Home Center controller go to device options by clicking the following icon yy Select the device options tab Then specify to which group and what devices are to be associated Sending relevant information to devices added to associated groups may take even a few minutes WARNING When Fibaro Switch sends control commands and a new command is issued then the current one command transmission i
8. e or personal injuries arising from or related to the use of the Device 14 The guarantee shall not cover e mechanical damages cracks fractures cuts abrasions physical deformations caused by impact falling or dropping the device or other object improper use or not observing the operating manual e damages resulting from external causes e g flood storm fire lightning natural disasters earthquakes war civil disturbance force majeure unforeseen accidents theft water damage liquid leakage battery spill weather conditions sunlight sand moisture high or low temperature air pollution e damages caused by malfunctioning software attack of a computer virus or by failure to update the software as recommended by the Manufacturer e damages resulting from surges in the power and or telecommuni cation network improper connection to the grid in a manner inconsistent with the operating manual or from connecting other devices not recommended by the Manufacturer e damages caused by operating or storing the device in extremely adverse conditions i e high humidity dust too low freezing or too high ambient temperature Detailed permissible conditions for operating the Device are defined in the operating manual e damages caused by using accessories not recommended by the Manufacturer e damages caused by faulty electrical installation of the Customer including the use of incorrect fuses e damages caused by Custome
9. g device does not send control commands Double clicking key sends turn on command dimmers memorize the last saved state e g 50 brightness 2 commands are sent when device is turned off Enabling device does not send control commands Double clicking key sends turn on command and dimmers are set to 100 brightness NOTE Parameter 15 value must be set to 1 to work properly This activates the double click functionality dimmer roller shutter control Parameter no 13 Assigns bistable key status to the device status default value 0 Available configuration parameters 0 On Off device changes status on key status change 1 Device status depends on key status ON when the key is ON OFF when the key is OFF Info Remote control from Fibaro System Is Still Possible This function is useful When you want display status of external devices e g Motion Sensor in Fibaro System Parameter no 14 Switch type connector you may choose between mono stable and bi stable switches default value 1 Options for changing the parameter 0 mono stable switch 1 bi stable switch Parameter no 15 Operation of the Dimmer and Roller Shutter Controller enabling this option allows the user to dim lighting shut roller by associating Dimmer Roller Shutter Controller and holding or double press of double switch only mono stable switch default value 0 Available configuration parameters 0 Dimmer Roller Shutter Con
10. ician Observe national regulations DANGER Danger of electrocution Even when the device is turned off voltage may be present at its terminals Any works introducing changes into the configuration of connections or the load must be always performed with disconnected voltage disable the fuse TIPS e Do not connect the device to loads exceeding recommended values e Connect only in accordance with the diagram presented in the manual Improper connections may be dangerous GENERAL INFORMATION ABOUT FIBARO SYSTEM FIBARO is a wireless system based on Z Wave technology FIBARO provides many advantages when compared to similar systems In general radio systems create a direct connection between the receiver and transmitter But the radio signal is weakened by various obstacles located on its path apartment walls furniture etc and in extreme cases it fails to transfer required data The advantage of FIBARO system is that its devices apart from being transmitters and receivers of signals they are also a signal duplicators When a direct connection path between the transmitter and the receiver can not be established the connection may be achieved through other intermediate devices FIBARO is a bi directional wireless system It means that the signal is not only sent to the receivers but also the receivers send the confirmation of its reception This operation confirms their status so to check whether they are active S
11. k by pushing three times key no or push button B located inside the housing of the device For bi stable switch perform 3 position changes WARNING Fibaro Switch cancels the learning mode after key no 1 is pressed once Therefore pressing key no 1 four times will not add the devices to the network The same applies to push button B WARNING Fibaro Switch is set by default to operate with mono stable switches i e single pole switch or bell switch While adding Fibaro Switch to the network with bi stable switches ensure that all switch contacts are open off because closing them results in activating the push button and this will prevent adding the device to the network During the installation it is recommended to use a mono stable keys or push button B STEP 6 The controller indicates when the device is correctly added to the network see the manual of Home Center controller 2 Resetting Fibaro Switch Fibaro Switch provides three methods for resetting Method Reset by removing Fibaro Switch from the existing Z Wave network The device may be removed using the controller that has the ability to include exclude devices from to Z Wave network see the manual of controller Method II Within 5 sec after connecting mains voltage supply Fibaro Switch allows the user to reset settings by single pressing S1 key and then holding key S2 Method Ill Reset by holding B button for 3 sec after connecting
12. malfunctions The device does not respond to a pre programmed transmitter e Make sure that the maximum range is not exceeded and the signal path is not obstructed by metal surfaces such as metal cabinets etc e Make sure the device is not in the programming mode or repeat the programming process IX GUARANTEE 1 The Guarantee is provided by FIBAR GROUP Sp z o o hereinafter Manufacturer based in Poznan ul Lotnicza 1 60 421 Poznan entered in the register of the National Court Register kept by the District Court in Poznan VIII Economic Department of the National Court Register no 370151 NIP 7811858097 REGON 301595664 2 The Manufacturer is responsible for equipment malfunction resulting from physical defects manufacturing or material of the Device for 12 months from the date of its purchasing 3 During the Guarantee period the Manufacturer shall remove any defects free of charge by repairing or replacing at the sole discretion of the Manufacturer any defective components of the Device with new or regenerated components that are free of defects When the repair impossible the Manufacturer reserves the right to replace the device with a new or regenerated one which shall be free of any defects and its condition shall not be worse than the original device owned by the Customer 4 In special cases when the device cannot be replaced with the device of the same type e g the device is no longer available in the
13. ntre in your country www fibargroup com
14. onnecting wires bracket rings etc in order to prevent interferences Metal surfaces in the direct vicinity of the antenna e g flush mounted metal boxes metal door frames may impair signal reception Do not cut or shorten the antenna its length is perfectly matched to the band in which the system operates Note It should be noted that only the push button connected to S1 terminal and service push button B enables learning mode Include Exclude ae ee Led ee DICTIONARY e INCLUSION Adding a device sends Node Info frame to enable user to add it to Fibaro system Home Center e EXCLUSION Removing removing a device from the Fibaro radio system e ASSOCIATION controlling other devices of Fibaro system e MultiChannelAssociation controlling other multichannel devices of Fibaro system lll Activating Fibaro Switch 1 Installing the Fibaro Switch STEP 1 Connect the device in accordance with the circuit diagram presented in Figure 1 Switch on 230V of the mains voltage Adding Removing Fibaro Switch to from Z wave network STEP 2 Fibaro Switch must be placed within the range of Home Center controller as adding mode requires direct communication with the controller STEP 3 Find key no 1 which allows to switch circuit 1 on in accordance with the diagram STEP 4 Set the Home Center controller in add remove mode see the controller s manual STEP 5 Add Fibaro Switch to the networ
15. r s failure to provide maintenance and servicing activities defined in the operating manual e damages resulting from the use of spurious spare parts or accessories improper for given model repairing and introducing alterations by unauthorized persons e defects caused by operating faulty Device or accessories 15 The scope of the guarantee repairs shall not include periodic maintenance and inspections in particular cleaning adjustments operational checks correction of errors or parameter programming and other activities that should be performed by the user Buyer The guarantee shall not cover natural wear and tear of the Device and its components listed in the operating manual and in technical documentation as such elements have a defined operational life 16 If a defect is not covered by the guarantee the Manufacturer reserves the right to remove such defect at its sole discretion repairing the damaged or destroyed parts or providing components necessary for repair or replacement 17 This guarantee shall not exclude limit or suspend the Customer rights when the provided product is inconsistent with the purchase agreement This Device may be used with all devices certified with Z Wave certificate and should be compatible with such devices produced by other manufacturers Any device compatible with Z Wave may be added to Fibaro system FIBARGROUP FIBARO In case of any technical questions contact customer service ce
16. r to set response of devices to alarm situations response to data frames ALARM REPORT and SENSOR_ALARM_REPORT Fibaro switch responds to the following types of alarms e General Purpose Alarm GENERAL PURPOSE ALARM 0x00 e Smoke Alarm ALARM CO2 0x02 ALARM CO 0x01 ALARM SMOKE 0x03 e Water Flooding Alarm ALARM WATER 0x05 e Temperature Alarm ALARM HEAT 0x04 Alarm data frames are sent by devices that are system sensors e g flood sensors smoke detectors motion detectors etc The device may respond in the following manner to received data frames settings are configured in configuration parameters see section V Configuration e 0 DEACTIVATION the device does not respond to alarm data frames e 1 ALARM ON the device turns on after detecting an alarm e 2 ALARM OFF the device turns off after detecting an alarm e 3 ALARM FLASHING the device periodically changes its status to the opposite when it detects an alarm lights on off alternately Vil Operating Fibaro Switch Fibaro Switch may be operated using the following control elements any controller compatible with the system e g Home Center controller a mobile phone e g iPhone and phones from other manufacturers with appropriate software tablet such as iPad PC using a web browser push buttons connected to outputs S1 and S2 service button B located inside the housing activates learn mode Vill Procedures for
17. s interrupted to send new commands FGS211 Fibaro Switch supports the operation of multi channel devices Multichannel devices are devices that include two or more circuits inside one physical unit V Configuration The following settings are available in the Fibaro interface as simple options that may be chosen by selecting the appropriate box In order to configure Fibaro Switch using the Home Center controller go to device options by clicking the following icon yy Parameter no 1 Activate deactivate functions ALL ON ALL OFF default value 255 Options for changing parameter 255 0 1 2 Available configuration parameters 255 ALL ON active ALL OFF active 0 ALL ON is not active ALL OFF is not active 1 ALL ON is not active ALL OFF active 2 ALL ON active ALL OFF is not active Parameter no 3 Automatic turning off relay after set time default value 0 Available configuration parameters 0 Auto OFF enabled 1 Auto OFF disabled Parameter no 4 Time after witch relay is automatically turned off default value 20 200ms Available configuration parameters 1 255 10ms 2 5s time after relay is automatically turned off Parameter no 6 Sending commands to control devices assigned to 1 st association group key no 1 default value 0 Available configuration parameters 0 commands are sent when device is turned on and off 1 commands are sent when device is turned off Enablin
18. troller control is not active 1 Dimmer Roller Shutter Controller control is active Parameter no 16 Saving the state of the device after a power failure Fibaro Switch returns to the last position saved before a power failure default value 1 Options for changing the parameter 0 1 0 Fibaro Switch does not save the state after a power failure it returns to off position 1 Fibaro Switch saves its state before power failure Possibility to change the configuration of the following parameters 30 33 0 DEACTIVATION the device does not respond to alarm data frames 1 ALARM RELAY ON the device turns on after detecting an alarm 2 ALARM RELAY OFF the device turns off after detecting an alarm 3 ALARM FLASHING the device periodically changes its status to the opposite when it detects an alarm within 10 min Parameter no 30 General Alarm set for relay no 1 default value 3 byte ALARM FLASHING Parameter no 31 Alarm of flooding with water set for relay no 1 default value 2 byte ALARM RELAY OFF Parameter no 32 Smoke CO CO2 Alarm Set for relay no 1 default value 3 byte ALARM FLASHING Parameter no 33 Temperature Alarm set for relay no 1 default value 1 byte ALARM RELAY ON Parameter no 39 Active alarm time default value 600 Available configuration parameters 1 65535 ms VI Additional Functionality Operating alarm data frames Fibaro system allows use

Download Pdf Manuals

image

Related Search

Related Contents

ユーザーズ ガイド  BEDIENUNGSANLEITUNG mit EQ3-2 & EQ5 Montierung  mode d`emploi de votre espace privé - Credit  Sony VAIO VPCSB4AFX  Homecleaner - Cleanfix AG  Guía del usuario PicoScope Serie 6000A/B  User manual extension  user manual  V7 Laser Toner for select SAMSUNG printer - replaces CLTC4092S  Compresseur PromaAir 20L  

Copyright © All rights reserved.
Failed to retrieve file