Home

Temperature/Humidity Monitor User`s Manual HT-360

image

Contents

1. QD button to change the digit Third push button into alarm rang setup LED display slow LO ALARM ON RH and set Hi alarm Humidity Push GL or LAD button to change the digit Fourth push button into alarm range setup LED display show HI ALARM ON RH and set Hi alarm Humidity Push QD or GD button to change the digit If you want to store this setup push the Enter i button If not push Mode putton tnen exit alarm setup 10 9 Battery replacement AN If the LO Battery LED were turn on please replace the battery immediately 10 External DC Power External AC to DC adapter Voltage 9Vpc 8 14Vp Max Socket pin Positive Ground Casing External Diameter 5 5mm internal Diameter 2 0 mm Turn off the instrument Open the battery cover and remove the battery Replace with four 9V NEDA 1604 IEC 6F22 or JIS 006P size battery Install the battery cover 11 Safety Precaution For cleaning the instrument use a soft dry cloth Never use a wet cloth solvents or water etc Datalogging capacity with Memory Size 500 data sets Operation Altitude Up to 2000M Operating Environment Indoors use This instrument has been designed for being used in an environment of pollution degree 2 12 Software installation ome e Please put the CD in the PC that will Om O 3 Pam Cum be connected to this meter ian my Canpowrr f E i E E Please select the USB driver
2. coal dust grease attached on the protective tube of temperature probe will slow down the heat conduction of the thermocouple and cause measuring error Therefore it should be cleaned periodically The metal coating of thin thermocouple should be replaced properly upon the occurrence of corrosion Cleaning and inspection of humidity sensor The smoke and dust attached on the humidity sensor will slow down the function of humidity sensor and cause measuring error Therefore it should be cleaned periodically Blow off the dust with mild compressed air instead of water or alcohol The aluminum plate inside the humidity sensor should be replaced upon the occurrence of corrosion 15 16 14 End of life Caution this symbol indicates that equipment and its accessories shall be subject 16 to a separate collection and correct disposal 15 Auto Stores Data Push M lt ei button into time clock and date setup Push Mode button again into auto stores time clock setup This time LED display show auto stores data time gt you can push IL to change time unit Max auto stores data time 23hour 59min 59sec Push LIJ or CAD button to change the digit If you want to store this setup push inter i button If not push iM gt e button then exit auto stores data time setup If stores data will be writhing into memory LED display show Record on Single data memory Push Record button each time to store the disp
3. that will be installed such as E TM 185D PL 2303 Driver Installer exe windows 2000 SP4 windows XP SP2 click twice on the left key of the mouse to install the USB driver eseese BBHUHB e Select the SETUP EXE i e E TM A Setup 7M 185 fn fe 185D SETUP EXE and installs the desktop icon OG A Welcome to the TM 185 Setup Wizard his well instal TM 195 1 0 02 on your Comenser is recommended tha you clove al othe applications balore tA Click Newt to continue of Canal to ext Setup Tack out the CD from PC after completed the installation of the desktop icon 13 e Use the USB cable to connect the meter and computer according to the drawing a a AA e Select the desktop icon and click twice on left key of the mouse to run the procedure 13 Maintenance Do not use the meter in an environment with severe change do not store the unit in an environment with high temperature high humidity and high vibration Take battery off if the meter has not been used for a long period of time The Diode temperature probe is used to measure temperature and the capacitive humidity sensor is used to measure take humidity The thermocouple and humidity sensor will start aging under the influence of oxidation reduction corrosion pollution vaporization diffusion or other metallurgy The aging process will affect its precision seriously Cleaning and inspection of temperature probe The smoke
4. Display 14 External power DC 9V 15 ARM Hold 16 Battery Cover 17 Record Button 18 Memory Button 19 USB interface 20 Data Logger Box interface OHNAASWRH 6 LED description 8 000 6000 7 Clock and Date setup Push AMA button into time clock and date ILL setup e Push A button to select option to adjust e Push CID or C button to change the digit Push button to store the setup then exit the mode If not push Modei button then exit clock and data setup This meter clock to introduce 12 hour time if you want change 24 hours push 1 2 3 4 5 6 7 8 9 10 Temperature reading value Humidity reading value Time reading value Time unit Data logger symbol Temperature unit Alarm symbol HI symbol LO symbol Humidity unit 8 Alarm Range Setup e Push Alarm button into alarm setup LED will display ALARM ON If you just reading alarm setup please push J button again LED will display ALARM OFF First push M button into alarm range setup LED display show LO ALARM ON C or F and set LOW alarm Temperature Push or C D button to change the digit If test Temperature or Humidity exceed set range buzzer were bleep at this time socket output sin wave signal at 2000Hz terminal blocks were short Second push lt 4 button into alarm range setup LED display show HI ALARM ON C or F and set Hi alarm Temperature Push QD or
5. Temperature Humidity Monitor User s Manual Temperature Humidity Monitor HT 360 Table of Contents 1 PREFACE neniesan eiia 2 2 CHARACTERISTICS 2 3 GENERAL SPECIFICATIONS 2 4 ELECTRICAL SPECIFICATION 4 5 INSTRUMENT DESCRIPTION 5 6 LED DESCRIPTION eee 7 7 CLOCK AND DATE SETUP 8 8 ALARM RANGE SETUP essc 9 9 BATTERY REPLACEMENT 11 10 EXTERNAL DC POWER 12 11 SAFETY PRECAUTION 12 12 SOFTWARE INSTALLATION 13 13 MAINTENANCE snene 16 14 END OF LIFE uu eee 17 15 AUTO STORES DATA 0 17 16 SINGLE DATA MEMORV 18 17 VIEWING LOGGED DATA 18 1 PREFACE Thank you for your patronage please do read the operation instructions in details before you use this meter so that operate correctly make a machine give play to the best function 2 CHARACTERISTICS LED display It shows both the value of temperature and humidity It give the selection of C or F Real time data Data Hold function Alarm function 3 General Specifications e Display Double rows LED humidity MAX reading 999 and temperature MAX reading 1999 Temperature sensor Diode e Humidity Sensor Capacitor Sensor e Sampling 1 times second e Power AC to DC Adapter 9V 1 A Backup Power 9V battery NEDA1604 IEC 6F22 or JIS 006P Only data logger use I Resolution 1 RH gt 0 1 C gt 0 1T Size 260x178x47mm LxW
6. lay reading and memory location in memory 17 Viewing logged Data Push Memory button into view logged data mode push Memory button again exit view logged data mode In view logged data mode push MM button reading stores time push LzD button to change the temp unit Push Entec rr button to change view logged data 17 18 14
7. xH Weight 1000g Operating Temperature and Humidity 20 C 60 C lt 95 RH Non condensing Storage Temperature and Humidity 10 to 60 C lt 70 RH Non condensing Consumption Current 4700mA Standard Accessories User s manual 9V battery gt AC to DC Adapter Carrying case gt LCD Wall Mount i Accessories Length of wire for sensor 1 meter Accessories Datalogging Box Datalogging capacity with Memory Size 30 000 data sets MINI USB 4P MALE to USB A Type cable Install CD disk 4 Electrical Specification e Measurement Range Humidity 5 95 Temprature 20 0 C 60 0 C 4 0 F 140 0 F e Temperature Accuracy 1 0 C 1 8 F 5 0 C 40 0 C 23 F 104 F other 2 0 C 3 6 F e Humidity Accuracy 2 0 RH at 25 C 35 RH 80 RH 2 5 RH at25 C 10 35 80 90 other 5 0 RH at 25 C lt 10 RH gt 90 RH Notel If you require more accurate we can do it according to your requirement Note2 When the AC adaptor is off will start the backup power only to provide Data Logger use the LED won t be lightened Note3 Datalogging operation instruction at Install CD disk 5 Instrument description Temperature amp Humidity sensor Time Set Button Alarm Set Button C F Set Button Down Button Enter Button Hold Button UP Button LED Display Data Logger Box optional Data Logger Box interface 10 Power Switch 1 1 Terminal Blocks Always off 12 Audio Output 13 Lo Battery LED