Home

to the LEAD ACID User Manual for your 1.5kw

image

Contents

1. Input 100 240VAC 50 60Hz 14 8 1 The rated input current is 14 at 115VAC and 8 1A at 220VAC b 48V 5A 240VAC 48V 24 54 1 15 The maximum output current is 25 at input 220VAC and 24 5A at input 115VAC iii LED Label It is the important symbol to evaluate whether the charger works normally The LED will flash red several times when AC is first connected then the LED will flash green once The number of red flashes denotes the present curve e g If the red flashes three times it means the present curve 15 curve 3 and so on Red Green flash Battery Disconnected one second interval Red flash Repair Battery three seconds interval Red flash lt 80 Charge Indicator one second interval Yellow flash gt 80 Charge Indicator one second interval Green flash 100 Charge Indicator one second interval iv Charging Curves Label Ten charging curves respectively represent different capacities of the Lead acid battery 14 means the equalizing current Algorithms 105 means the procedure code from the manufacturer e g the charger of Lead acid flooded battery 48V for example 48V Flooded Battery 1 5KW Charger Algorithms_105 1 105 126ah 3 36a 6 262 315 8 37A_ 152 1 2 8 12 06 4 182 219 581A 9 454 544 1447 Charging Curves Setup curve 1 10 1 The LED will flash red several times when AC power is connected
2. fitted onto the vehicle panels Wiring Diagram SPOP Heat strinktube Note Thermal sensor and LED share the connector SP1310 P Strapping which pairs up with the charger s communication port SP1312 S Label f Res s il ED Labet tabel sensor should be fixed on the battery shell Recommend to place it in a LED middle position between two cells sure the DC is near the charger s output terminal Plug in the connectors before Version Label tcs Charging Place the LED at the conveniently location A thermal Bar Code connected to the battery properly V Appearance Labels Please check carefully the labels the casing of the charger before using in order to completing the transaction check the label on the charger before using it can provide some help for you to understand the performance and the specification of the charger i Bar Code Label Attaches on the output terminal of the charger For example SN10071001 1007 Production batch number 1001 Bar code number SN10071001 48 25 Hardware model 48V 25A 48 25 1 6 HD VER 1 6 Version number from the manufacturer li Model Label take the model 48 25 for example INDUSTRIAL BATTERY CHARGER Inout 100 240VAC 50 60Hz 14 8 1A Output 48 25 9240 48 24 5 0115 24 cells TCCH 48 25 Environmental Enclosure IP46 a
3. HF PFC 1 5KW Lead acid Battery Charger Models Lead acid V out Nominal A out Max Battery Charger TCCH 24 40 36 33 48 25 60 20 96V 40A 33A 25 20 TCCH 72 16 16A TCCH 84 14 14A 96 12 96 130 12A 120 10 10 144 08 8A TCCH 156 08 8A Size mm 348 L 180 W 140 H Product Summary amp Application Scopes The charger is applicable for various Lead acid batteries like Flooded GEL AGM hemi colloid etc It features light weight small volume stable performance high efficiency and reliable security etc It can be switched automatically between the floating and balancing charging and also has the protection functions of reverse connection output short circuit and overload and so on The charger is widely used for battery charging cycles in electric vehicles such as electric forklift golf cars electric trucks electric tour bus electric yacht cleaning machines or Uninterruptible Power Supply UPS solar energy wind power dynamo and electric communication system on the railway etc ll Technical Target AC Input Voltage Range AC85V AC265V AC Input Frequenc 45 65 Hz AC Power Factor 20 98 Full Load Efficienc 293 Mechanical Shock amp Conformance to Vibration Resistance Level SAEJ1378 Standard Environmental Enclosure Operating Temperature 40 455 40 F 131 F Storage Temperature 40 4100 40 F 212 TF 10 Cha
4. age limited current charging or constant power charging Charging voltage goes up gradually until the maximum point V4 under constant voltage the charging current goes down 13 or the charging time reaches 53 it enters the next step 4 Trickle charge charge current turns to 14 Maximum voltage is V5 charging limited time is S4 5 Floating charge charge voltage is V6 charging time is S5 b Temperature compensation curve single cell 4 29 30CWE 0 003V T 0 0027 0 2 544 V 1 298 2 45V 2 a SS ee 200 0 250
5. and then the LED will flash green once The number of red flashes denotes the present curve E g If the red flashes three times it means the present curve is curve 3 2 To choose another curve please cut off the power supply first then uncover the label pressing the button while connecting the power If you want to choose curve 3 release the button after the 3rd LED Flash Now the selected curve e g curve 3 will be recorded in memory If you want the charger to work with the selected curve e g curve 3 cut off the power and reconnect it Note 10 charge curves are only available for volume order instead of sample order Vill Common Faults amp Solutions In case of the charging fails please examine all the outside lines carefully to make sure that they are connected correctly Apart from the circuit s failure please check the failure code of charging LED and handle it according to the following table LED Flashing Wrong Battery Overcharged Battery Overheated Es RGRGR____ Incorrect AC Input Voltage RGRGRG___ External Thermal Sensor Fault EJ RGRGRGR Communication Interface Fault Charger Overheated Charger Relay Fault 9 GRGR______ Charger Itself Fault Note 1 R red G green 2 _ denotes one second pause 3 Above LED flashing sequence is one cycle the LED will flash repeatedly if the fault has not been removed Solutions A Wrong Battery Verify the battery vo
6. ltage range matching with charger or inspect the battery for damage A Overcharged Confirm the battery capacity and the selected curve are matched or if the battery is defective A Battery Overheated Check the temperature at the external thermal sensor If overheated the charger will start the battery protection A Incorrect AC Input Voltage Check that the AC input voltage is in accordance with the requirement A External Thermal Sensor Fault Ensure connect the thermal sensor correctly A Communication Interface Fault Make sure the communication have been correctly connected or if it is damaged A Charger Overheated Check if the ambient temperature is too high or the ventilation is smooth A Charger Relay Fault Repair A Charger Itself failure Repair IX Charging Curve 1 The charging curve is custom build to your battery set a Typical charge curve for flooded Lead Acid Trojan batteries under temperature 25 V4 I vA V3 Al 1 Pre charge after connecting the charger and battery pack the charger detects the voltage OF OT 0 a5 T of the battery pack It will pre charge the cells or the pack when the voltage is between V1 V2 with constant current of 1 when the battery voltage reaches V2 or the charging time reaches 51 it will enter the next stage of charging 2 Constant current charging charging current is 12 when the charging voltage reaches V3 it will enter the next step of charging 3 Constant volt
7. rging Curves Charging Mode Available Intelligent temperature compensation Charging Control never to be charge off or charge due lll Protection Features 1 Thermal Self Protection When the internal temperature of the charger exceeds 75 the charging current will reduce automatically If it exceeds 85 C the charger will shut down protectively When the internal temperature drops it will resume charging automatically 2 Short circuit Protection When the charger encounters unexpected short circuit it will automatically stop to output When fault removes the charger will re start in 10 seconds 3 Reverse Connection Protection When the battery is polarity reversed the charger will cut off the connection between the internal circuit and the battery and refuses to start It can avoid any destroy 4 Input Low voltage amp Over voltage Protection When the input Voltage is lower than 85V or higher than 265 the charger will shut down protectively and automatically resume working with the voltage is normal again IV Main Accessories amp Wiring Diagram Accessories Thermal Sensor TC 615 together with LED TC 618 as per the specific vehicle model or a single Thermal Sensor TC 615 Functions Thermal sensor TC 615 provides the real time detection of the battery s temperature in the charging process to prevent charge off or charge due LED TC 618 shows the state of the charging such as lt 80 or gt 80 or 100 and can be