WALL MOUNTED FAN COILS - sinclair air conditioners
Contents
1. Healthy filter Fig 22 12 3 Mount the air filter properly along the arrow direction in Fig d and then close the panel cover 12 3 1 Cleaning and Maintenance Take out the healthy filter before cleaning and reinstall it after cleaning according to the installation instruction Pay special attention that silver ion filter can t be cleaned with water while active carbon photocatalyst low temperature conversion LTC catalyst formaldehyde eliminator catechin or mite killing filter can but can t with brush or hard things Dry it in the shade or sun after cleaning but not by wiping 12 3 2 Service Life 1 The healthy filter commonly has its usage lifetime for one year under normal condition As for silver ion filter it is invalid when its surface becomes black green 2 This supplementary instruction is provided for reference to the unit with healthy filter If the graphics provided herein is different from the physical goods the latter one shall prevail The quantity of healthy filters shall be based on the actual delivery 27 Take back of electrical waste Information for Users to Disposal of electrical and electronic equipment private households Icon on the product or in the accompanying documentation means that used electric or electronic products must not be disposed together with domestic waste For the correct disposal of the product hand it over to a
2. 4 2 Wired Controller Operation 1 DO NOT install the wired controller in the place water leakage 2 DO NOT knock throw or frequently turn on off the wired controll 1 a TIMER ERROR AZ 1 1 0N OFF O i H H SWING ors Ej i HR E mw AC lt FAN W AA J SPEED 9 SLEEP V Eji 3 7 SAVESET erger OUT ENV ani 34 12 4 rit T DEBUG m i T me E TEST r SW nol ah a 13 COOL DRY A A FAN HEAT riven DA sa a ON oC pe 15 Fig 3 STRUCTURE OF EACH PARTS TIMER ON OFF MODE button FAN display Auto High Mid Low 0 Temp Adjust up z 3 MODE Coo Dry Heat and Fan 14 E re 1 Energy Saving display 11 Temp Adjust down 1 1 Fan Coil Unit Wall Mounted Type 4 3 Wired Controller Operation 4 3 1 ON OFF 1 Press ON OFF button this unit will start working 2 Press ON OFF button again this unit will stop working 4 3 2 FAN 1 This fan runs at the following speed HIGH MED 2 Dry mode the fan speed will be automatically set to LOW 4 3 3 TEMP ADJUST 1 Press TEMP ADJUST key A Press it to increase the temp Vv Press it to decrease the temp Press the key once to change the temp by 1 C each time 2 The temp range in each operation mode HEAT 16 C 30 C COOL 16 C 30 C DRY 16 C 30 C FAN Can not set temp 4 3 4 SET SWING 1 Press the SWING button
3. 0 Q the unit is stopped sometimes there is swoosh or a gurgle the sound is due to refrigerant flowing they are not malfunctions In COOL mode sometimes the mist emitted from the air outlet vent When the indoor temperature and humidity are very high this phenomenon would happen This is caused by the room air is swiftly cooled down After running for a while indoor temperature and humidity will fall down the mist will die away Creaking noise can be heard when start or stop the unit E co ee ee 0 N This is caused by the deformation of plastic due to E 4 the changes of temperature 18 Fan Coil Unit Wall Mounted Type The unit can not run Is Temp setting suitable Were inlet and outlet vents obstructed Is filter dirty Ci i Are the windows and doors clothed 4 Did Fan speed set at low speed Is there any heat sources in the room Cooling Heating efficiency is not good The unit is interfered by abnormal or frequent functions switchover occasionally the controller cannot operate At this time you need to pull out of JU 0 0 on the plug and reinsert it a en Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged The air humidity is on the high side Condensing
4. 2 Under Cool mode the initial value is 24 C 75 F Under Heat mode the initial values 24 C 75 F 3 Auto mode is not available in this mode Na te Le Gia Sane COOL i DRY SG FAN z HEAT e SLEEP SLEEP button Press this button to select Sleep On Sleep Off If power is on Sleep Off is default If the unit is turned off the Sleep function setting will be not retained in memory If Sleep function is on the mark of Sleep will display In this mode the time of timer can be adjusted Under Fan and Auto modes this function is not available e FAN FAN button Press this button Auto Low Medium High speed can be circularly selected After powered on Auto fan speed is default Under Dehumidify mode Low fan speed is default pe ey a Low aM Medium aff High Note Under the Dry mode the fan speed isn t adjustable low fan speed is default e CLOCK CLOCK button Press Clock button to set the time of clock When blinks and displays you can set the time by pressing or button If no button is pressed within 10 seconds the remote will revert back to the normal display Press again to accept the setting If it is set the first time 12 00 is the initial value Note If mark displays on the LCD it means it is the time of clock if not it is the time of timer Fan Coil Unit Wall Mounted Type e LIGHT LIGHT button Press this button to select LIGHT On Off in the displayer When the LIGHT On is
5. showing SAVE COOL for the first time of setting the initial temperature is 26 then press MODE button it changes to energy saving setting of heating mode showing SAVE HEAT for the time of setting the initial temperature is 20 C The upper limit temp is set at the SET TEMP the lower temp limit is set at the ROOM TEMP press ON OFF button to switch over the upper lower temp limit setting press A and Vv to adjust the temperature the range is Fiig 4 16 30 C After finishing the setting press FAN and simultaneously again for 5 seconds and exit the SAVE menu 2 After the operation above SAVE will be display on the liquid crystal panel then neither the remote controller nor the wired controller the user use to set the temperature the SET TEMP will not exceed the range that has been set For example in the Fig 2 we set temp range from 23 C to 28 C then the user can only adjust the temp between 23 C and 28 C by the remote controller or the wired controller 3 If the upper limit is the same with the lower limit that the system can only run at this temperature 4 To cancel the energy saving press the button of FAN and WV simultaneously for 5 seconds in the status of OFF but temp limit will be keep until next time to set the energy saving function 5 After the power cut the energy saving function will still be store in memory NOTE The upper limit can not be lower than the lower limit
6. Where is pre covered with plastic granula 3 Be sure that the rear panel has been fixed firmly enough to withstand the weight of an adult of 60kg further more the weight should be evenly shared by each screw ha 50mm Fiig 15 9 2 Install the piping hole 1 Make the piping hole 55 in the wall at a slight downward slant to the outdoor side 2 Insert the piping hole sleeve into the hole to prevent the connection piping from being damaged when passing through the hole Outdoor Indoor Wall pipe LITZ 055 9 3 Install the water drain pipe ime 1 For well draining the drain hose should be placed J at a downward slant 2 Do not wrench or bend the drain hose or flood its end by water 3 When the long drainage hose passing Wrenched Bent through indoor should wrap the insulation materials NOTE mr ie Re When connecting the electric wire if the wire length is not enough please contact with the gt lt gt lt authorized service shop to buy a exclusive electric Flooded wire that is long enough and the joint on the wire are not allowed e The electric wiring must be correctly connected wrong connection may cause spare parts malfunction e Tighten the terminal screw in order to prevent loose e After tighten the screw slight pull the wire and confirm whether is it firm or not e f the earth wire is wrong connection that may cause electric shock e The cover plate must be fixed and tighten the
7. pipe connection Sketch pp 25 12 Check after installation and test Operation 9 26 1 Notices for operation Earth The ground be connected If not please ask the qualified person nel to install Furthermore don t connect each wire to the gas pipe water pipe drainage pipe or any other improper places Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the airconditioning Capacity If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Fan Coil Unit Wall Mounted Type Be sure to pull out the power plug when not using the air codictionary for a long time Otherwise the accumulated dust may cause fire or electric shock Don t block the air intake or outlet vents of both the units It can decrease the air conditioning capacity or cause a malfunction Select the most appropriate tempremature ae ais Keep room cooh er than outside about 5 degree iy i 2 EN a It can preclude the electricity wasted Keep combustible spray away from the units more than 1m It can cause a fire or explosion The airflow direction can be adjusted appropriately At operating adjust the vertical airflow direction by adjusting the louvers of upward downward direction And then hold two ends of left and right louver to adjust the horiz
8. state press MODE and button simultaneously to switch between C and F 3 6 Changing batteries and notices 1 Slightly to press the place with kg along the arrowhead direction to push the back cover of wireless remote control As show in figure 2 Take out the old batteries As show in figure 3 Insert two new AAA1 5V dry batteries and pay attention to the polarity As show in figure 4 Attach the back cover of wireless remote control As show in figure NOTE e When changing the batteries do not use the old or different batteries otherwise it can cause Sketch map for changing batteries the malfunction of the wireless remote control e f the wireless remote control will not be used for a long time please take them out and don t let the leakage liquid damage the wireless remote control e The operation should be in its receiving range e t should be placed at where is 1m away from the TV set or stereo sound sets e f the wireless remote control can not operate normally please take them out after 30s later and reinsert if they cannot normally run please change them Fan Coil Unit Wall Mounted Type 4 Wired Controller Operation optional 4 1 Notice before starting the unit 1 To ensure the heat exchanging the air in the fan coil of the unit must be exhausted before using 2 Before starting the unit make sure that the cable connection of the fan coil is correct and no sundries in the duct
9. the time of clock meaning the setting succeeds Press the TIMER ON again to cancel the setting e TIMER OFF BUTTON Press the TIMER OFF button to set the timed Off The procedures are similar as above 3 5 Operation of wireless remote control 3 5 1 Guide for operation General operation 1 Press SLEEP button to set the sleep state 2 Press TIME ON and TIME OFF button to scheduled the unit ON OFF 3 Press LIGHT button to control on and off the indicator board This function maybe not available for some units 3 5 2 Guide for operation Optional operation 1 After powered on press ON OFF button the unit will start to run Note When it is powered off the guide louver of main unit will close automatically Fan Coil Unit Wall Mounted Type 2 Press MODE button select desired running mode or press COOL or HEAT mode to enter the corresponding operation directly 3 Press or button to set the desired temperature 4 Press FAN button to set fan speed from AUTO FAN LOW MID and HIGH 5 Press _ button to select SWING mode 3 5 3 Operation of wireless remote control 1 Press and buttons simultaneously to lock or unlock the wireless remote control If it is locked the mark will display when pressing any button the mark gg will blink for three times but the air conditioner has no despondence If unlocked the mark will disappear 2 Switch between Fahrenheit and Centigrade 3 When unit is under Off
10. Finally wrapit with tape Water drainage pipe Fig 17 Fixing hook Mounting Mounting paor plate Fig 18 O ring to FCU pipe O Connection nut Spring washer Connection pipe nnection pipe shall be installed in place so as to guarantee the reliable connection Hex nut diameter Tightening torque N m Oo 1520 O 15 20 O o 09 52 31735 50 55 60 65 70 75 Note Firstly connect the connection pipe to the FCU pipe then to the connection pipe pay attention to the piping bending do not damage the connection pipe the joint nut couldn t tighten too much otherwise it may cause leakage Connection nut Be sure there is an interval of 6 7mm when the fitting is completed N Before installed the two pipes must be N tightened with the steps of the connection nut D Be sure there is an N interval of 6 7mm when the fitting is completed Wa NZ Nut DANADTTOTDTOATTTTZO Ne Spring washer Connection pipe 24 Fan Coil Unit Wall Mounted Type 11 External water pipe connection sketch 11 1 Pipe connectionsketch Fan coil Rear view Two Way Valve Provided by contract install Water flow Water outlet Diameter 12mm Water inlet Diameter 12mm Connection pipe Provided by contractor installer Connection nut Nut Washer Torque wrench Provided by factory ee Spring washer Ar 7 FCU pip
11. LIGHT buttonLIGHTset the mark will be displayed and the indicator light in the displayer will be on When the LIGHT Off is set the mark w will disappear and the indicator light will be off 3 3 Operation of wireless remote control Note This is a general remote control it could be used for multiple types functions of air conditioners For some models without the functions specified here we preserve the right to not to inform exclusively e X FAN X FAN button 1 Press this button to turn on off the X FAN function 2 The function is not available for this mode e button Presetting temperature can be decrease the temperature by 1 degree Celsius once press and hold for more than two seconds so that we can change the temperature continuously The minimum and maximum setting range of the temperature is 16 to 30 degree Celsius e button Press this button increase the temperature by 1 degree Celsius once Press and hold for more than two seconds so that we can change the temperature continuously The minimum and maximum setting range of the temperature is 16 to 30 degree e TEMP TEMP button Press this button to select the display of either indoor setting temperature or indoor ambient temperature When the indoor unit powered on firstly setting temperature display is default Change status to to display the ambient temperature If received control signal in 5 seconds the display temp will revert back to setting tem
12. USER MANUAL SINCLAIR AIR CONDITIONING User Notice D This symbol stands for items should be forbidden Q This symbol stands for the items should be followed Thank you for choosing SINCLAIR fan coils please read this owner s manual carefully before operation and keep it for fucture reference The products in this manual may be different from the real one according to different models some models have displayer and some models without displayer the position and shape of the displayer please refer to the real one This appliance is not intended for use by persons including children with restricted physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Mno not dispose this product as unsorted municipal waste Collection of such waste separately for special treatments necessary Contents 1 NOUCES for operatio siessen aaa a aa 1 2 Notices for USG anaana a E E A A a a 3 3 Name and function of each part pp 4 4 Wired Controller Operation optional pp 9 5 EMEFGENCY OPCTatlON eieaeoeaii ani a 15 6 MFOUDIGSHOOUING apinn r tence a 18 7 Notices for installation pe 20 8 Installation dimension diagram pp 22 Os US Call MEUN a E 23 10 Install the CONNECTION pipe pp 24 11 External water
13. centralized controller Fiig 10 After a power cut off the locked function will be disabled e While a long distance monitor is connected When a long distance monitor connects with the wired controller the long distance monitor not only can make a real time control of the velocity temperature mode ON OFF of the wired controllers but also can disable some or all of the functions of the wired controllers If all the functions of the wired controllers are locked the buttons of the wired controller and the remote controller are all disable and the code CC will display at the ROOM TEMP location If one or some of the functions are locked the other functions still work and nothing will display on the panel 14 Fan Coil Unit Wall Mounted Type When the functions are locked the lock function can only be canceled by the long distance monitor or by pressing MODE Y for 5 seconds The lock function can be kept in the memory after the power off 4 3 14 Set the address code of the wired controller Fig 11 1 An address code of long distance monitoring can be set to the wired controller and the main board 2 Press MODE A for 5 seconds in the OFF status to enter the address writing menu Fig 10 then the present address code will flickeringly display at the TIMER location the default code is 0 and DEBUG will also flickeringly display at the same time Press A V to choose the address code with the range of 1 2999 Pres
14. connection wire if it is poor installed that the dust moisture may enter in or the connection terminal will be affected by outside force and will cause fire or electric shock Sm 23 Fan Coil Unit Wall Mounted Type 9 4 The piping can be lead out from left left rear 1 When routing the piping and wiring from the left side of the unit cut off the tailings from the chassis in necessary Show in Fig 16 1 Cut off the tailings 1 when routing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping 2 Take out the piping from body case wrap the piping electric wire water pipe with tape and pull them through the piping hole As show in Fig 17 3 Hange the mounting slots of the FCU on the upper tabs of the rear panel and check if it is firm enough As show in Fig 18 4 The height of the installed location should be 2 5m or more from the floor 10 Install the connection pipe 1 Align the center of the piping pipe with the relevant valve 2 Place the nut spring washer washer O ring cross the pipe sequentially and keep them tightly close to each other with a distance of 6 7mm from the the pipe end 3 Screw in the pipe nut by hand and then tighten the nut with spanner and torque wrench refer to the following 4 If supplied by the manufacturer the co Inlet water side pipe Outlet water side Tailing2 Tailing1 Inlet side piping
15. e O ring Wrench Connection nut Spring washer Connection pipe Fig 19 11 2 Motorized Valve All units must be equipped with a motorized valve because of the following main reasons 1 There would be a water flood risk for some units without motorized valves in the event that they stop under the cooling conditions 2 Under the cooling and heating conditions energy loss would happen to the chilled water and hot water Note e The pipe must be wrapped by heat insulation material to prevent condensing water drips e t is prohibited to bind directly the water valve wire and sponge up with the copper tube as there would be probably a short circuit or even electric leakage The right way is letting the water valve wire go through the pipe sleeve and then binding the sponge and pipe sleeve e It is prohibited to put the valve core upside down e Power supply of motorized valve is 230 V using 24 V motorized valve can lead to its destruction 25 Fan Coil Unit Wall Mounted Type 12 Check after installation and test operation Check after installation Is the voltage in accordance with the rated It may cause electric malfunction or damage the part voltage marked on the nameplate Is the electric wiring and piping connection It may cause electric malfunction or damage the part installed correctly and securely Has the unit been connected to a secure earth It may cause electrical leakage connection Is the powe
16. e just starts or the unit runs heat mode under low water temperature the fan will stop running to prevent the chilled wind blowing out 2 4 Anti heat wind function In order to ensure comfort of the users under circumstances such as the cool mode just starts or the unit runs cool mode under hot water temperature the fan will stop running to prevent the hot wind blowing out Fan Coil Unit Wall Mounted Type 3 Name and function of each part 3 1 The unit 9 The patten in displayer 2 E X Cool s Dry Wirel SG 0 Power cable uy Fan remote control XX Heat 2 Remote control ly R O Run 3 Front panel 88 Set temp 4 Filter D 5 Guide louver 6 Wall pipe 7 Bind tape 8 Drain pipe 8 Fig 1 Fan Coil Unit Wall Mounted Type 3 2 Operation of wireless remote control Note Be sure that there are no obstructions between receiver and remote control Donot drop or throw the remote control Don t let any liquid drop into the remote control or leave the remote control under the sunlight or place where is very hot e ON OFF Press ON OFF button to turn on off the unit When the unit is turned off the Timer Sleep function will not be retained in memory but the time will be retained and is still displaying e MODE MODE button 1 Press this button Auto Cool Dry Fan Heat mode can be selected circularly
17. e or deformation e Insert the air filter Reinsert the filters along the direction of arrowhead and then to cover the cover and clasp it 16 Fan Coil Unit Wall Mounted Type 5 4 Clean and care e Check before use 1 Be sure that nothing obstructs the air outlet and intake vents 2 Check that whether ground wire is properly connected or not 3 Check that whether the batteries of air conditioner are changer or not e Maintain after use 1 Turn main power off 2 Clean the filter and the unit body 17 Fan Coil Unit Wall Mounted Type 6 Troubleshooting CAUTION Don t attempt to repair the air conditioner by yourself it can cause an electric shock or fire Please check the following items before asking for repair it can save your time and money Not operate immediately when the air conditioner is restarted Once the air conditioner is stopped it will not operate in approximately 3 minutes to protect itself There s unusual smell blowing from the outlet after operation is started The unit has no peculiar smell by itself If has that is due to the smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation lt lt x The air conditioner is started when it is running or
18. e should follow the local code 4 The power source must offer reliable grounding terminal Make sure not to connect the ground wire with the following Tap water pipe Gas pipe Contamination pipe Other places that professional personnel consider unreliable 5 The type and rated values of fuse is justified according to the silk print on the fuse or PCB 21 Fan Coil Unit Wall Mounted Type 8 Installation dimension diagram Space to the ceiling Air outlet side Space to the floor The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Fig 14 22 Fan Coil Unit Wall Mounted Type 9 Install the unit 9 1 Install the rear panel 1 Always mount the Wall Wall rear panel horizontally Due Mark on the middle of it G ee space WN Space to the water tray of the unit to the to the has been adopted the both ole way drainage design the above outlet of water tray should a ne gp AN be aaitsted slignuly down eft Bee es ee AAG Right when installing that is taking 55mm 55mm the outlet of the water tray Rear piping hole Rear piping hole as the center of a circle the included angle between the evaporator and level should be 0 or more that is good for condensing water drainage 2 Fix the rear panel on the wall with screws
19. eaning air conditioner or it may cause electric shock e Never sprinkle water on the unit for cleaning because it can cause an electric shock e Volatile liquid e g thinner or gasoline will damage the air conditioner So wipe the units with a dry soft cloth or a cloth slightly moistened with water or cleanser 5 3 1 Clean the front panel When cleaning the front panel please dip the cloth into the water temperature of 45 C below then to dry the cloth and wipe the dirty part Note Please do not to immerse the front panel in water due to there are microcomputer components and circuit diagrams on the front panel 5 3 2 Clean the air filter Recommended once every three months Note If dust is much more around the air conditioner the air filters should be cleaned many times After taking off the filter don t touch the fin of indoor unit in order to avoid hurt your fingers e Take down the air filter At the slot of surface panel to open an angle pull the air filter downward and take it out please see the Fig 13 a b e Clean the air filter To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 C degree and dry it in the shade Note Never use water above 45 to clean or it can cause deformation or discoloration Never parch it by fire or can cause a fir
20. ion Installation in the following place may cause malfunction If it is unavoidable contact with service center please 1 Place where strong heat sources vapors flammable gas or volatile object are emitted 2 Place where high frequency waves are generated by radio equipment welders and medical equipment 3 Place where a lot of salinities such as coast exists 4 Place where the oil machine oil is contained in the air 5 Place where a sulfured gas such as the hot spring zones is generated 6 Other place with special circumstance 7 3 The Unit Installation Position Selection 1 The air inlet and outlet vent should be far from the obstruction make sure that the air can be blown through the whole room 2 Select a position where the condensing water can be easily drained out 3 Select a location where the children can not reach 4 Can select the place where is strong enough to withstand the full weight and vibration of the unit And will not increase the noise 5 Be sure to leave enough space to allow access for routine maintenance The height of the installed location should be 250cm or more from the floor 6 Select a place about 1m or more away from TV set or any other electric appliances 7 Select a place where the filter can be easily taken out 8 Make sure that the unit installation should accord with installation dimension diagram requirements 9 Do not use the unit in the immediate surroundings
21. of a laundry a bath a shower or a swimming pool 7 4 Safety Requirements For Electric Appliances 1 The power supply be used the rated voltage and AC exclusive circuit the power cable diameter should be satisfied 2 Don t drag the power cable emphatically 3 It should be reliably earthed and it should be connected to the special earth device the installation work should be operated by the professional The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading 20 Fan Coil Unit Wall Mounted Type 4 The min distance from the unit and combustive surface is 1 5m 5 The appliance shall be installed in accordance with notional wiring regulations 6 An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring Note e Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reliable and no short circuit in the diagram e Wrong connection may cause fire 7 5 Ground requirements 1 Air conditioner is type electric appliance thus please do conduct reliable grounding measure 2 The yellow green two color wire in air conditioner is ground wire and cannot be used for other purpose Cut off and fixed by screw as grounded is not permissible otherwise is would cause serious damage 3 The earth resistanc
22. ontal air flow Louver of left right direction Louver of upward downward direction Fan Coil Unit Wall Mounted Type Don t insert your hands or stick into the air Don t blow the wind to animals and plants directly intake or outlet vents It can cause a bad influence to them Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shock and malfunction Or CO toxicsis may occur for incomplete burning Fan Coil Unit Wall Mounted Type 2 Notices for use 2 1 Working principle for cooling Principle e The unit absorbs energy from the air indoors and takes the energy away through circulation of cooling water so as to reduce indoor ambient temperature Accordingly the cooler the water the larger the cooling capacity 2 2 Working principle for heating Principle e Air circulation which is forced by the fan transfers the energy from hot water to the air indoors so as to increase indoor ambient temperature e Accordingly the hotter the water the larger the heating capacity e Because heating capacity of such air circulation system is closely related to the temperature of hot water if water temperature is not high enough additional heating appliance is recommended to use together 2 3 Anti cool wind function In order to ensure comfort of the users under circumstances such as the heat mod
23. or else the system will default the higher one to be upper limit if there is no operation in 20 seconds the SAVE menu will automatically shut down 4 3 8 Memory function Fig 5 Press the MODE button for 10 seconds in the OFF status the memory function can be switch over If 01 is showed it means the memory function is on or else if O2 is showed it means the memory function is off Press ON OFF button to exit If there is no operation is 20 seconds the memory function menu will be shut of and the present setting will be stored Fiig 5 11 Fan Coil Unit Wall Mounted Type 4 3 9 Malfunction display Fig 6 If there is a malfunction during the operation code will be showed It means evaporator sensor malfunction is Fig4 The meaning of other error codes is as below Fig 6 Note If the wired remote controller shows the error code EH lease cut off the power and find the professional to fix the problem 12 4 3 10 Sensor setting Fig 7 Press the FAN SWING button for 10 seconds in the OFF status to enter the senor setting menu A code will be displayed on the ROOM TEMP 01 means the indoor unit sensor and 02 means the wired controller senor press A and W to chose the senor If there is no operation in 20 seconds the system will exit this menu and the present setting will be saved or else press ON OFF button to save and exit 4 3 11 System paramete
24. perature When unit is off indoor setting temperature display is default Note This function is only available for certain models e TURBO TURBO button In Cool or Heat mode press this button to turn on off the Turbo function Note This function is not available for this model Fan Coil Unit Wall Mounted Type 3 4 Operation of wireless remote control Note This is a general remote control it could be used for multiple types functions of air conditioners For some models without the functions specified here we preserve the right to not to inform exclusively e SWING UP AND DOWN BUTTON Press this button to adjust swing angle which circularly changes as below Sh Ea Ea E OFF J44 A This is a general use remote control If remote control shows the following three kinds of status that the swing status of main unit will bes N N When the guide louver start to swing up and down if turn off the Swing the air guide louver will stop at current position SI which indicates the guide louver swings up and down between the five positions e TIMER ON BUTTON Press the TIMER ON button to set the timed On Press once to increase or decrease the minute by 1 minute If pressed and held for 2 seconds the minute will increase or decrease constantly by 1 minute If held constantly for more than 5 seconds the minute will begin to change in every 10 minutes Press TIMER ON again to accept the setting and ON will show besides
25. place for take back where it is collected free of charge By correct disposal of the product you can help to preserve valuable natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local authorities nearest collection point in Waste Acts of respective country in the Czech Republic in Act no 185 2001 Coll in the wording of later regulations In case of incorrect disposal of this waste a fine can be imposed according to national regulations al x Manufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD UK Supplier and technical support Nepa spol s r o Purkynova 45 612 00 Brno Czech Republic www hepa cz Toll free info line C 420 800 100 285
26. r cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient cooling heating capacity 12 1 Test Operation 12 1 1 Before test operation 1 Do not switch on power before installation isfinished completely 2 Electric wiring must be connected correctly and securely 3 All the impurities such as scraps and thrums must be cleared from the unit 12 1 2 Test operation method 1 Switch on power press ON OFF button on the wireless remote control to startthe operation 2 Press MODE button to select the COOL HEAT FAN to check whether theoperation is normal or not 26 Fan Coil Unit Wall Mounted Type 12 2 Installation and Maintenance of Healthy Filter e Installation Instructions 1 Forcibly pull the panel for a specific anglefrom the two ends of the front panel accordingto the arrow direction Then pull the air filterdownwards to remove it See Fig 20 2 Mount the healthy filter onto the air filter asshown in Fig 20 Fig 21 If the air filter cannot be installed please mount the healthy filter onthe front case as shown in Fig 22 ee Fig 21 Air filter 3 Mount the air filter properly along the arrowdirection in Fig 23 and then close the panel cover
27. rs display Fig 8 Press FAN SWING for 10 seconds while the system is ON to enter the system parameters displa interface The temperature of the water valve pump and surface cooler in the system The temperature of the surface cooler is display at TIMER the two position value display at TEMP SET means Valve 1 and Valve 2 the status of the pump displays at ROOM TEMP and 1 means ON while 2 means OFF Press ON OFF button to exit or else the system will automatically exit after 30 minutes Fan Coil Unit Wall Mounted Type Fiig 7 Fiig 8 13 Fan Coil Unit Wall Mounted Type 4 3 12 Button lock function Fig 9 Press the A Y button for 5 seconds EE will appear at ROOM TEMP and the buttons will be locked Presses the A V button for 5 seconds again the button locked function will be canceled Fiig 9 4 3 13 Monitoring of the wired controllers The wired controllers can be monitored by a connected centralized controller or long distance monitor e While a centralized controller is connected Fig 10 A centralized controller can monitor all the wired controllers and disable them When the wired controllers are rocked by the centralized controller the button of the wired controller and the remote controller are all locked and CC will appear at the ROOM TEMP location The lock function can also be disabled by the
28. s ON OFF to confirm then if the address code stop flickering it means the code of the wired controller Fiig 11 is successfully written if DEBUG stop flickering that means the code of the mainboard is successfully written 3 If there is no operation within 20 seconds the menu will automatically exit or else press the button MODE A for 5 seconds to exit 5 Emergency operation 5 1 Indicator light control of the displayer When sleeping at night the user can get the indicator light off 1 Get the displayer indicator light on When setting the light function the mark 8 will display on the remote controller screen by pressing this button In which case the displayer indicator light will be on if the AC receives Fiig 12 this signal 2 Get the displayer indicator light off If cancel the light function the mark 8 will disappear on the remote controller screen by pressing this button In which case the displayer indicator light will Manual switch be off if the AC receives this signal 5 2 Emergency operation If the wireless remote control is lost or broken please use the manual switch button The unit will run at the mode which was setted before turned off but the temperature and fan speed cannot be changed Open the front panel the manual switch is on the edge as Fig 12 15 Fan Coil Unit Wall Mounted Type 5 3 Clean and care Caution e Turn power off and pull out the power plug before cl
29. the swing function will be ative 2 Press again to stop the swing function 4 3 5 SET MODE Every time press this key to change the operation mode in order of g COOL gt DRY FAN _ 1 In COOL mode COOL key will be lighted and set temp must be lower than temp If set temp is higher than room temp this unit won t run in COOL mode and only fan can operate 2 In DRY mode DRY key will be lighted and internal fan will work at high speed within a certain temp range This mode is more efficient than DRY function in COOL mode and it can save the energy 3 In HEAT mode HEAT key will be lighted Set temp must be higher than the room temp If set temp is lower than the room temp this unit won t run the HEAT mode 4 In FAN mode FAN key will be lighted In the meantime The room temp can t be adjust but it will be shown on the LCD of the controller 4 3 6 SET TIMER Starting time can be set in OFF mode and stopping time can be set in ON mode Press the TIMER button to set timer press the A button or the W button once set time will be raised or reduced by 0 5h then press TIMER button again to confirmThe range of set time is 0 5n 24h 10 Fan Coil Unit Wall Mounted Type 4 3 7 Energy Saving Setting Fig 4 1 In the status of OFF press the button FAN and simultaneously for 5seconds the SAVE menu will appear and comes to the energy saving settings of cooling and dry
30. water over flowed Wireless remote control is not available o oo The connection position of the unit drainage pipe is loosed The sound of fan relay is switching on or off If water leakage in the room When the unit turn off That is due to the water flowed to the reverse direction In HEAT mode when the temperature of the heat exchanger is very low that will stop deliver air in order to prevent cool air In COOL mode when the temperature of the heat The unit cannot deliver air exchanger is very high that will stop deliver air in order to prevent hot air In dehumidifying mode sometimes indoor fan will stop in order to avoid condensing water be vaporized again restrain temperature rising If unit is running under the high humidity for a long Noise from the unit emitted time the moisture will be condensed on the air outlet grill and drip off 19 Fan Coil Unit Wall Mounted Type 7 Notices for installation 7 1 Important Notices 1 The unit installation work must be done by qualified personnel according to the local rules and this manual 2 Before installing please contact with local authorized maintenance center if unit is not installed by the authorized maintenance center the malfunction may not solved due to discommodious contacts 3 When removing the unit to the other place please firstly contact with the authorized Maintenance Center in the local area 7 2 Basic Requirements For Installation Posit