Home

User manual

image

Contents

1. Is the connecting correct Maybe there is a fault in the inside circuit Maybe there is a fault in the inside circuit Only when load is running this LED will flash If the operating power is too low the spacing interval of flashing will be prolonged so that people is under the delusion that LED isn t burning Please connect with technical Supporter to replace this meter Check that the power supply indicator is burning If the operating power is too low the spacing interval of running will be prolonged so that people is under the delusion that register can t run Please connect with technical Supporter to replace this meter Check the external voltage source Ui is 5 27V DC Check correct connecting connect 5 27V DC to connector 20 anode and the signal wire S to connector 21 cathode Please connect with technical Supporter to replace this meter Please connect with technical Supporter to replace this meter 1
2. and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock Maintenance or repair should be performed by qualified personnel familiar with applicable codes and regulations Use insulated tools to maintain or repair the meter Make sure the protection cover is in place after maintenance or repair Case is sealed failure to observe this instruction can result in damage for meter Problem check Solution No light for the Power Is AC power supply Check switch or circuit breaker Supply indicator connected to the and fuse or thermal cut off meter Is the 1 and 4 Reinstall terminal screws on the 1 connecting correct and 4 Make sure all screws are fixed Than there should be a 230V 50Hz AC voltage between the terminal screws on the 1 and 4 when power supply is input Maybe there is a Please connect with technical fault in the inside Supporter to replace this meter circuit Continue Problem No light for the consumption indicator The register can t run No pulse output Pulse output rate wrong A fe L 92 COMPLIANT 2002 95 EC Check Solution Is the load running Is the operating power too low Maybe there is a fault in the inside circuit Is there a power supply inside the meter Is the operating power too low Maybe there is a fault in the inside circuit Is DC power supply connected to the meter
3. current total energy circularly to indicate the user for the wrong connection The period of circular display is 3 seconds 230V 5 32 A 50Hz 230V 5 32 A 50Hz Oke ofa lola Ce lola CE c Meter version When the meter re switch on the power it will display the meter version for 3 seconds then display the other items As follows indication XTM Metering version is U1 10 230V 5 32 A 50Hz Ra 0 5 Whiimp C R 0 5 Wh imp Loa ce Pulse output The XTM1D V1 1 DIN rail energy meter is equipped with a pulse output which is fully separated from the inside circuit That generates pulses in proportion to the measured energy for remote reading purposes and accuracy testing The pulse output is a polarity dependant passive transistor output requiring an external voltage source for correct operation For this external voltage source the voltage Ui should is 5 27V DC and the maximum input current limax is 27mA DC To connect the impulse output connect 5 27V DC to connector 20 anode and the signal wire S to connector 21 8 cathode The meter pulses 2000 per kWh 0 5Wh imp 1 10 Troubleshooting A AUTION During repairing and maintenance do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage Turn off and lock out all power supplying the energy meter
4. User manual XTMI18SA XTM1D V1 1 5 32A DIN rail single phase two wire energy meter 1 1 1 2 L3 4 1 7 y 1 8 1 9 1 10 Safety instruction Foreword Performance criteria Specifications Basic errors Description Dimensions Installation Operating Troubleshooting Technical support 1 1 Safety instructions Information for Your Own Safety This manual does not contain all of the safety measures for operation of the equipment module device because special operating conditions and local code requirements or regulations may necessitate further measures However it does contain information which must be adhered to in the interests of your own personal safety and to avoid material damages This information is highlighted by a warning triangle and are represented as follows depending on the degree of potential danger Caution Means hazard of electric shock and failure to take the necessary safety precautions will Warning Means that failure to observe the instruction can result in death serious injury or considerable material damage A result in death serious injury or considerable material damage Qualified personnel Commissioning and operation of the equipment module device described in this manual may only be performed by qualified personnel Qualified personnel in the sense of the safety information contained in this manual are persons who are authorized to commission start up ground a
5. done by qualified personnel e Never break the seals and open the front cover as this might influence the functionality of the meter and will avoid any warranty e Do not drop or allow physical impact to the meter as there are high precision components inside that may break or render the meter measure accurate infrared Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible However deviations from the description cannot be completely ruled out so that no liability can be accepted for any errors or omissions contained in the information given The data in this manual are checked regularly and the necessary corrections are included in subsequent editions We are grateful for any improvements that you care to suggest Subject to technical modifications without notice Copyright Copyright XTM Metering October 2012 All rights Reserved It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission Any duplication is a violation of the law and subject to criminal and civil penalties All rights reserved particularly in the event of a patent award or utility model registration Registered trademarks XTM Metering is registered trademark of Yueqing Xintuo Electronic Science amp Technology The other names appearing in this manual may be trade names the use of which by third parti
6. emperature International standard Accuracy class Protection against penetration of dust and water Insulating encased meter of protective class 1 4 Specifications Nominal voltage Un Operational voltage Insulation capabilities AC voltage withstand Impulse voltage withstand Basic current Ib Maximum rated current Imax Operational current range Over current withstand Operational frequency range Internal power consumption Test output flash rate RED LED Pulse output rate pins 20 amp 21 Power supply indicator Green LED Consumption indicator RED LED Data display mode Data save 1 5 Basic errors 0 05Ib Cos 1 O 1Ib Cos 0 5L Cos 0 8C O 1Ib Imax Cos 1 0 2Ib Imax Cos 0 5L Cos 0 8C 1 6 Description Case mUoUQOW gt Terminal block Protection cover Security hasp lt 75 lt 95 10 C 50 C 30 C 70 C IEC 62053 21 1 IP51 II 230V AC 161 300V AC 2KV for 1 minute 6KV 1 2uS waveform 5A 32 A 0 25A 32A 960A for 0 01s 50Hz 10 lt 2W 10VA 2000 impulses per kWh 0 5Wh imp 2000 pulses per kWh 0 5Wh imp Meter is connected and working OK Flashing at load running 7 1 digits for LCD display The data can be stored more than 20 years when power cut 1 5 1 5 1 5 1 0 1 00 1 0 Register LCD display Material Window of register Case Terminal block Protection cover 1 7 Dimensions Height Width De
7. es for their own purposes may infringe the rights of the owners 1 2 Foreword Thank you for purchasing the XTM Metering XTM1D V1 1 DIN rail single phase two wire energy meter The XTM Metering XTM 1D V1 1 energy meter is the most advanced type electronic kWh meter available at the market With the XTM Metering product range we have introduced a large scale of energy meters on the market suitable for 110V AC to 400V AC 50 or 60Hz Besides the normal energy meters we also developed our own pre paid meters with chip card chip card re loaders and a complete PC management control system For more information on other product please contact our sales department at sales Although we produce the XTM Metering XTM 1D V1 1 meter according to IEC 62053 21 and our quality inspection is very accurate there might always be a possibility that your product shows a fault or failure for which we do apologize Under normal conditions your product should give you years of benefit and pleasure In case there is problem with the energy meter you should contact your dealer immediately All energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim for warranty Therefore NEVER open an energy meter or break the seal of the energy meter The warranty time is 6 months after installation and only valid for construction faults 1 3 Performance criteria Operating humidity Storage humidity Operating temperature Storage t
8. h connection diagram 1 Inlet phase line 4 Inlet neutral line 3 Outgoing phase line 6 Outgoing neutral line 20 and 21 Pulse output contact 1 9 Operating Working indication There is a white LED which has two colors green and red burning in the front panel of XTM 1D V1 1 When the meter works normally this LED will display green When meter is going wrong or no power supply the LED will turn off Consumption indication There is a LED which has two colors green and red burning in the front panel of XTM 1D V1 1 When consumption happens the LED will flash and display red The more quickly LED flash the more consumption there is For this LED the flash rate is 2000 impulses per kWh 0 5Wh imp Reading the meter XTM 1D V1 1 is equipped with an LCD display the screen will show the following energy data and indication message a Current total energy When the meter is in normal working it will display only 7 1 energy data with The unit is kWh These data can not be reset to zero by the user Example Total energy is 4574899 1 kWh 230V 5 32 A 50HZ Ra 0 5 Whiimp R 0 5 Whiimp LEa CE b Indication for reverse use When the meter is in the wrong connects with the incoming line and the outgoing line that is the incoming line is connected to the position for the outgoing line and the outgoing line is connected to the position for incoming line it will happen reverse The LCD display will show HELP 1 and the
9. nd label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved byXTM Metering Proper handling The prerequisites for perfect reliable operation of the product are proper transport proper storage installation and assembly as well aS proper operation and maintenance When operating electrical equipment certain parts of this equipment automatically carry dangerous voltages Improper handling can therefore result in serious injury or material damage Use only isolated tools Do not connect while circuit is live hot Do not connect the meter to a 3 phase 400VAC network Place the meter only in dry surroundings Do not mount the meter in an explosive area or exposed to dust mildew and insects Make sure the used wires are suitable for the maximum current of this meter e Make sure the AC wires are connected correctly before activating the current voltage to the meter e Do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage e Make sure the protection cover is placed after installation e Installation maintenance and repair should only be
10. ould comply with the specifications of the building electrical design and all local regulations An external fuse or thermal cut off which will used as a over current protection device for the meter must be installed on the supply side wire and it is recommended that the over current protection device be near the meter so that it is convenience for the operator The over current protection device should comply with the specifications of the building electrical design and all local regulations This meter can be installed indoor directly or in a meter box which is waterproof outdoor subject to local codes and regulations To prevent tampering secure the meter with a padlock or a similar device The meter has to be installed against a wall which is fire resistant The meter has to be installed in a good ventilated and dry place The meter has to be installed in a protection box in dangerous or dusty environment The meter can be installed and used after being tested and sealed with a letter press printing The meter can be installed on a 35mm DIN rail The meter should be installed in an available height so that it is easy to read When the meter is installed in an area with frequent surges due to e q thunderstorms welding machines inverters etc protect the meter with Surge Protection Devices After finishing installation the meter must be sealed to prevent tampering Connection of the wires should be done in accordance with the underneat
11. pth Weight 1 8 Installation PC inflammable retarding PA inflammable retarding PA inflammable retarding PA inflammable retarding 1 J y see sep x oc eee toe Hee are sI E gt 18 _ r mi D TEE S Ek T 4 TE 116 mm 17 5 mm 59 mm 0 12 Kg net WES n AAT RU g Ce ALU Sy Da LEH j aPUH J N NLX CAUTION e Turn off and lock out ali power supplying the energy meter and the equipment to which it is installed before working on it e Always use a properly rated voltage sensing device to confirm that power is off WARNING Installation should be perrurmed by qualified personnel familiar with applicable codes and regulations Use isolated tools to install the meter Fuse or thermal cut off or single pole circuit breaker can t be fitted on the Supply line and not the neutral line Case is sealed failure to observe this instruction can result in damage for meter We recommend that the connecting wire which is used to connect meter to outside circuit should be sized according to local codes and regulations for the ampacity of the circuit breaker or over current device used in the circuit An external switch or a circuit breaker should be installed on the inlet wire which will be used as a disconnection device for the meter And there it is recommendation that the switch or circuit breaker be near the meter so that it is convenience for the operator The switch or circuit breaker sh

Download Pdf Manuals

image

Related Search

Related Contents

Longue-vue étanche 7 x 35  Un homme qui dort - Over-blog  操作マニュアル  S4 User Manual CE 0107.book - Pdfstream.manualsonline.com  les fondamentaux du droit social appliqué au transport de voyageurs  Ethernet POWERLINK Controlled Node  Techniques recommandées pour la mise en culture de boutures d`if  取扱説明書 YHA-12  FrameMaker User Guide Templates  Data Access Studio Administrator`s Manual  