1. Fire Fite SICK 972 g LEE MES h NI FireFite Brand Fire Extinguisher User s Manual DRY POWDER FIRE EXTINGUISHER SQUEEZE GRIP CARTRIDGE TYPE IMPORTANT Please read carefully and save This user s manual contains important information about your fire extinguisher s operation If you are installing this fire extinguisher for use by others you must leave this manual or a copy of it with the end user Read extinguisher label and the entire user s manual carefully before installing or using the unit Make sure everyone in your Premises is completely familiar with the operation of the extinguisher and review the instructions regularly In an emergency you will not have time to read instructions Classes of Fire Suitability of Classes of Fire is clearly Marked on the Fire Extinguisher Fire extinguishers are classified by fire type The A B and C rating system defines the kinds of burning materials each fire extinguisher is designed to fight The numbers in front of the A B or C indicate the rating for size of the fire the unit can extinguish Using the wrong type of fire extinguisher can do more harm than good Make sure you understand which fire extinguisher to use on each class of fire A rm M Class A rating The agent powder is suitable for fighting small fires involving wood paper cloth rubber and some plastics aly 3 Class B rating The agent powder is suitable for fighting
2. if it gets wet or dirty Make sure the tamper indicator safety seal is still intact and the nozzle is clean and unobstructed Bharati Fire Engineers FireFite Fire Extinguisher User Manual Squeeze grip cartridge type 2 of 6 MAINTENANCE Maintenance is a thorough check of the extinguisher It is intended to give maximum assurance that a fire extinguisher will operate effectively and safely It includes a thorough examination for physical damage or condition to prevent its operation and any necessary repair or replacement It will normally reveal if hydrostatic testing or internal maintenance is required WARNING BEFORE SERVICING BE SURE THE EXTINGUISHER AGENT CYLINDER IS NOT PRESSURIZED THIS PROCEDURE IS BEST ACCOMPLISHED WITH THE EXTINGUISHER IN AN UPRIGHT POSITION AND ON A LEVEL SURFACE EXAMINE THE EXTINGUISHER CAREFULLY EVERY 12 MONTHS TO ENSURE EXTINGUISHER IS OPERABLE SUBJECT THE FIRE EXTINGUISHER FOR HYDRAULIC TEST MAXIMUM EVERY 3 YEARS as per BIS Guidelines As per the Guideline 1 3 of the Extinguisher in every Premises should be operated for Performance WE RECOMMEND TO TEST THE FIRE EXTINGUISHER EVERY YEAR AS A PRECAUTIONARY MEASURE DE PRESSURING INSTRUCTION OPENING THE SQUEEZE GRIP CAP INSTRUCTION Highly Skilled Job TO BE CONDUCTED BY A TRAINED PROFESSIONAL ONLY WE HIGHLY RECOMMEND IT TO BE SEND TO US FOR DE PRESSURIZING REFILLING AND SERVICING CAUTION IF NOT DONE PROPERLY MAY CAUSE SERIO
3. ER IS USED SEND THE EXTINGUISHER FOR RECHARGING TO US OR AN AUTHORIZED BHARATI FIRE ENGINEERS SERVICE STATION Only OUR authorized fire equipment dealer must refill this extinguisher The extinguisher must be refilled with the same chemical that it contained when it was first purchased Improper filling can result in non working or dangerous units CAUTION DO NOT RELY ON PARTIALLY USED OR DISCHARGED FIRE EXTINGUISHER Warranty Details Bharati Fire Engineers herein after referred to as BFE warrants this system to be free of defects in materials and workmanship for a period of 13 months from date of purchase BFE s WARRANTY adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that BFE s customers receive maximum coverage on each product The Product is warranties against Manufacturing Defects Any Extra Warranty availed during Procurement shall be separately certified If the system malfunctions or is found to be defective it will be repaired or replaced at no charge BFE s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or cur
4. US INJURY NOT TO BE DONE IF SERVICE ENGINEER IS NOT TRAINED AND CONFIDENT The Fire Extinguisher is Fitted with a Specialized Squeeze Grip Cartridge Type CAP This Cap is Fitted onto the Extinguisher with a Swivel Type External Ring This Ring contains 3 protruding slots to hold with a Spanner This Ring also Contains Vent Holes To De pressurize the Fire Extinguisher hold the Ring by Fixing a Spanner Suitable Size onto the Slots Then Very Slowly more the External Ring Anti Clockwise As soon as the Vent Hole move above the Internal Neck ring Seat a Slow Hissing Noise will Start Bharati Fire Engineers FireFite Fire Extinguisher User Manual Squeeze grip cartridge type 3 of 6 Simultaneously when you place your finger closer to the Vent Hole you will feel Airflow Stop Immediately The De pressurizing has started Keep the Extinguisher as it 1s till the sound and Air Completely Stops Then Continue the Anti Clockwise Rotation of the Ring The Cap Assembly along with the ring will then Easily Come out Maintenance procedure l Clean extinguisher to remove dirt grease or foreign material Check to make sure that the instruction sticker is attached and legible Inspect the cylinders for corrosion abrasion dents or weld damage If any damage is found hydrostatically test in necessary Note When cleaning avoid use of solvents around the CAP Assembly They could seriously damage the Cap and Safet
5. can support it like a wooden partition stud Secure mounting is needed so you can remove the extinguisher quickly and easily in an emergency Also if the extinguisher is not held securely it could drop to the floor and injure people or damage the extinguisher e Do not break the plastic loop Metal Seal Plastic Clip holding the safety pin in place This loop prevents accidental discharge of the fire extinguisher Break the loop only in an emergency before using the fire extinguisher o The extinguisher has a bracket for wall mounting Install the mounting bracket on a wooden stud or other solid surface that will support the weight of the extinguisher using the screws or bolts you purchased o After installing the mounting bracket replace the extinguisher on the bracket with the label facing outward so the label can be easily read INSPECTION MONTHLY CHECK THAT EXTINGUISHER IS CHARGED UNDAMAGED AND SEAL IS INTACT CHECK WEIGHT OF GAS CARTRIDGE IF WEIGHT LOSS IS MORE THAN 10 OF STAMPED WEIGHT SEND IMMEDIATELY FOR RECHARGING DO NOT CHECK THE PRESSURE OR TEST THE FIRE EXTINGUISHER BY SQUEEZING THE TRIGGER EVEN BRIEFLY ONCE USED IT WILL GRADUALLY LOSE PRESSURE AND WILL NOT BE FULLY CHARGED FOR USE IN AN EMERGENCY Check for signs of damage or misuse Make sure you can still read all the text on the label Carefully examine the surface of the extinguisher for corrosion You can help prevent corrosion by cleaning the extinguisher
6. hould therefore be recharged Inspect nozzle or the hose amp horn assembly for damage replace as necessary Blow air through nozzle or hose and horn to insure passage is clear of foreign material 9 Inspect the Cap assembly for corrosion or damage to hose thread connection Replace Cap assembly or component parts as necessary following the proper depressurization and recharge procedures If Cap removal is necessary complete all steps in the Recharge Procedure 10 Install nozzle or hose and horn assembly 11 Replace the extinguisher on the wall hanger or in the vehicle bracket making sure that it fits the bracket properly and the bracket is securely attached replace the bracket if necessary RECORD RECORD MAINTENANCE AND RECHARGE DATES ON ATTACHED TAG USE NOTE Persons expected to use this extinguisher should be trained in initiating its operation and in the proper firefighting technique Familiarize all personnel with this information before an emergency occurs Danger Make sure your extinguisher may be safely and effectively used on the small fire you want to fight Always use extreme caution when fighting any fire Fight a fire only where there is a clear escape path to allow you to get out safely 1f the fire gets worse Bharati Fire Engineers FireFite Fire Extinguisher User Manual Squeeze grip cartridge type 4 of 6 Warning Avoid breathing smoke and heated fumes stay low if necessary Burning materials wil
7. l release toxic fumes Inhaling these fumes may cause injury or death Caution Always stand back far enough away from the fire near an exit and make sure nothing is between you and your escape route If you get too close to a fire you risk getting burned or hit by splattering material like grease If the fire is too hot or smoky for you to get within 10 feet 3 meters DO NOT try to fight the fire yourself Evacuate immediately and call the Fire Department FIREFITE FIRE EXTINGUISHER TEMPERATURE SUITABILITY RANGE 30 C TO 55 C DESIGN PRESSURE 15 BAR KGF CM2 TEST PRESSURE MINIMUM 35 BAR KGF CM2 Specialized Products with Higher Test pressures also provided Certificate for same to be availed separately METHOD OF OPERATION 4 to 9 Kg 1 Pull Hold upright and Pull Pin 2 AIM LOW Point the extinguisher hose at the base of the fire 3 SQUEEZE The lever above the handle to discharge the extinguisher agent To stop the discharge release the lever 4 SWEEP the hose from side to side Keep the extinguisher aimed at the base of the fire and sweep back and forth until the flames appear to be out AFTER ANY USE RECHARGE IMMEDIATELY Bharati Fire Engineers FireFite Fire Extinguisher User Manual Squeeze grip cartridge type 5 of 6 RECHARGE REFILLING IF THE EXTINGUISHER IS OPERATED OR THERE IS DEPOSITION OF POWDER SEEN IN THE HOSE OR THE CAP ASSEMBLY THEN THIS INDICATED THE FIRE EXTINGUISH
8. rent heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of BFE s control The remedies of purchaser set forth herein are exclusive and the total liability of BFE with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall BFE be liable for consequential incidental or special damages Designed Manufactured and Marketed By BHARATI FIRE ENGINEERS An ISO 9001 2008certified company Corporate Office 206 B flying colours off L B S marg Near Checknaka Bus Stop Above Croma Mulund W Mumbai 400080 India URL www bharatifire com E mail bharatifireeng gmail com info bharatfire com Telefax 022 25681269 25684298 25601169 Plant A 427 TTC Indl Area M I D C Mahape Navi Mumbai 400709 Tel 022 27781561 562 Bharati Fire Engineers FireFite Fire Extinguisher User Manual Squeeze grip cartridge type 6 of 6
9. small fires involving grease oil gasoline Kerosene and other flammable liquids OK A5 Class C rating The agent powder is suitable for fighting small fires in live electrical equipment Bharati Fire Engineers FireFite Fire Extinguisher User Manual Squeeze grip cartridge type 1 of 6 INSTALLATION All fire extinguishers should be installed inspected and maintained in accordance with the IS 2190 BIS STANDARD FOR SELECTION INSTALLATION MAINTENANCE OF FIRST AID FIRE EXTINGUISHER CODE OF PRACTICE International standards such as National Fire Protection Association standard titled Portable Fire Extinguishers NFPA 10 BS standard EN 3 and the requirements of local authorities having jurisdiction may also be followed A Fire Extinguisher Should Be Mounted e In the vicinity of but not on or in a potential source of heat and or fire like an oven or stove e Where it is easy to reach near an exit or an escape route from the room e In a location that is convenient in plain sight and 3 1 2 to 5 feet 1 to 1 5 meters above the floor e Store the extinguisher high enough to keep it out of the reach of small children On a clean dry surface where the temperature does not go above or below the Range of Temperature of the Fire Extinguisher o Do not mount the extinguisher on drywall or plaster without adequate support Use strong screws or bolts to mount the bracket securely into solid wood or metal that
10. y Valve 2 Inspect the extinguisher for damaged missing or substitute part Only factory replacement parts are approved for use on FireFite fire extinguishers 3 CHECK the Cartridge for Weight ALSO CHECK THE GROSS WEIGHT OF THE EXTINGUISHER PERIODICALLY IF YOU FIND IT 10 LESS THAN THE STAMPED WEIGHT in any Case PLEASE SEND FOR RECHARGING TO US 4 Weigh the extinguisher and compare with weight printed in the Maintenance section on the nameplate label Recharge extinguisher if weight is not within indicated allowable tolerances Max 3 to 5 Tolerance 5 Visually inspect the SQUEEZE GRIP CAP ASSEMBLY If bent damaged or improper FINISH Remove and replace If Safety Valve is POPED UP This indicated over pressurized overcharged or Unwanted operation Depressurize the extinguisher and follow recharge instructions REMOVE Gas Siphon and Powder Siphon Blow Air and Clean Internal siphons Verify for Thread Damage or Siphon Damage 6 Inspect discharge lever for any dirt or corrosion which might impair freedom of movement Inspect carrying handle for proper installation If lever handle or rivets are damaged replace with proper FIREFITE parts 7 Install new tamper seal if broken and record service data on the extinguisher inspection tag 8 Remove nozzle or hose and horn assembly and visually inspect inside Cap body Chemical in the Cap body may indicate that the extinguisher has been partially discharged and s