Home

Salter Brecknell Weighing Products 1000 Armstrong Dr Fairmont

image

Contents

1. weight is in grams To download more detailed interface specifications please visit our web site at www salterbrecknell com 7010SB serial communications protocol TROUBLE SHOOTING Symptom Recommended Action Not weighing correctly OR Inaccurate weight Press ON OFF TARE key to zero the scale before placing an item on the scale OR The scale may need re calibration See calibration instructions page 5 Weight fluctuates Press ON OFF TARE key to zero the scale before placing an item on the scale OR Ensure scale is placed in a stable level environment free from vibration Lo is displayed Replace the battery Err is displayed The weight placed on the scale is over 9 Ibs 15 5 ounces Remove the weight from the scale OR The weight placed on the scale plus the Tare weight is over 9 Ibs 15 5 ounces Remove the weight from the scale After pressing the WT HOLD Key and placing a weight on the scale the weight will not hold in the display The continues to Hash viv naeia te BG kad Seat aa Remove weight from scale and place the weight in the center of the scale ig displayed The scale is under zero weight Press the ON OFF TARE key If problem is consistent your scale may require calibration see page 5 7 WT HOLD KEY This key is used when you are unable to view the displayed weigh
2. Salter Brecknell Weighing Products 1000 Armstrong Dr Fairmont Minnesota 56031 Toll Free 800 637 0529 Voice 507 238 8702 Fax 507 238 8271 Email sales salterbrecknell com www salterbrecknell com June 2003 Copyright 2001 2002 Salter Brecknell Weighing Products g SALTER Brecknell er anak Models 7010SB PC Interfaced Postal Scale UNPACKING YOUR SCALE NOTES Carefully unpack and inspect the shipping container for evidence of shipping damage If such evidence is discovered stop unpacking and immediately notify the shipper to arrange to have the shipment inspected by an authorized representative All damages must be promptly filed with the shipper 1 Open the box and carefully remove the scale from the shipping carton save the shipping carton for future use 2 Place the scale on a flat level surface free from vibration 3 Remove the AC adapter and the RS 232 interface cable from the packaging material 4 Before using your scale please plug the scale into a power outlet and turn on the scale for 10 minutes This will allow the scale to warm up and ensure accurate weighing INSTALLING THE BATTERY Use 9V ALKALINE BATTERY ONLY No other type provides a suitable power output To fit the battery remove the cover on the underside of the scale and push the connector firmly onto the battery terminals Refit the cover 10 TECHNICAL SUPPORT For techni
3. ale with a slightly damp cloth DO NOT immerse the scale in water or use chemical abrasive cleaning agents 4 Ifthe scale is not being used for a long period of time remove the battery or turn off the scale WARRANTY This product has a 90 day warranty from the date of delivery against defects in material and workmanship This warranty does not apply if the product was subject to misuse neglect damage or abuse Calibration is not covered under warranty SCALE CALIBRATION INSTRUCTIONS Periodically your scale may require calibration to ensure proper weighing You will need a 10 pound weight to calibrate the scale If calibration is performed with a weight other than 10 pounds it will cause your scale to weigh inaccurately Scale calibration is accomplished when needed by the following instructions Function Scale Response 1 Remove all weight from the scale 2 Press and hold the ON TARE key and press the lb oz grams key once SLPO SLP1 3 Press the ON TARE once to accept the sleep mode setting and enter into calibration mode 4000 10000 4 Press the ON TARE key once to zero the scale 2 2 0 eee eee ee 0 5 Place 10 lbs on the scale 0 008 6400 10 000 6 Press ON TARE key once to accept the calibration weight CAL then Err 7 Remove the weight from the scale press the ON TARE k
4. cal support please contact us Via Phone 507 238 8702 or 1 800 637 0529 Via Fax 507 238 8271 or 1 800 368 2042 E mail sales salterbrecknell com SET UP INSTRUCTIONS 1 Apply power to the scale by first plugging the round connector into the scale see below then plugging the square AC adapter into an outlet 2 Select an unused Serial DE 9 Communication Port located on the back of your PC COM 1 2 3 or 4 and attach the communication cable provided to your PC Attach the other end of the communication cable to the 7010SB scale in the SMALL plug jack located in the rear of the unit See below FUNCTION KEYS The Model 7010SB has three function keys to operate the scale They are ON OFF TARE WT HOLD and LB OZ GRAMS ON OFF TARE KEY The ON OFF TARE key performs three functions First it applies power to the scale second it tares the weight on the scale to zero third it will turn off the scale To use the tare feature 1 Place an empty container on the weighing platform 2 Press the ON OFF TARE key The scale will display zero weight 3 When an item is placed on the container the scale only displays the weight of the item not the weight of the container 4 To reset the scale for no tare remove the container and its contents from the weighing platform Press the ON OFF TARE key then to reset the scale to zero weight The tare function will work over the full weighing range of
5. ey to continue the normal weighing mode Note The Err displayed after completing calibration does not indicate a calibration error Since the scale only weighs up to 9 Ibs 15 5 oz the ten pounds on the scale causes the displayed message Err INTERFACING TO A PC The Model 7010SB interfaces to several Mailing and Internet Postage Software Programs A driver is not available from Salter Brecknell please contact the software manufacturer for their 7010 or 7010SB scale driver Salter Brecknell does offer a Active X control for you to develop your own interface driver ActiveX allows programmers to assemble reusable software components into application programs ActiveX components must be used is a 32 bit ActiveX compliant development environment such as Microsoft Visual Basic 5 0 Visual C Office 97 Visual FoxPro Borland Delphi and others To download the ActiveX Component and other use tools to help you write and interface to the 7010SB Visit our web site at www salterbrecknell com Salter Brecknell can only offer limited support to software developers INTERFACE SPECIFICATIONS Communications RS 232 No Handshake continuous transmit only Fixed 2400 Baud 8 data bits No parity 2 stop bits Fixes ASCII character continuous transmission Weight and Status Response lt STX gt X X X lt CR gt STATUS BIT DEFINITIONS S6 S5 S4 Definitions 0 0 0 na 0 0 1 na O 1 1 weightisin pounds ounces 1 0 O
6. t because an item is larger that the weight platter and display Pressing this key will hold the stable weight in the display To use the Weight Hold feature 1 Remove all items from the scale making sure the scale is at zero weight 2 Press the WT HOLD key The scale will display 0 0 The will flash indicating the weight hold feature is active 3 Place an item on the scale wait two seconds for the weight to become stable 4 When the weight becomes stable the will no longer flash 5 Remove the item from the scale The weight of the item will be held in the display 6 To remove the held weight press the WT HOLD key NOTE Only the held weight will transmit when interfacing to a PC SLEEP MODE CONFIGURATION The default setting for sleep mode is Off SLPO The sleep mode can be configured to On SLP1 via keyboard If there is no activity the scale will turn itself off after 30 seconds The sleep mode can be changed when needed by the following instructions Function Scale Response Remove all weight from the scale Press and hold the ON OFF TARE key and press the LB OZ GRAMS key once SLPO OFF Press the LB OZ GRAMS key to scroll to the next selection 0 SLP1 ON Press and hold the ON OFF TARE key for 5 seconds to accept the sleep mode setting and exit the configuration mode 4
7. the scale but will not extend the overall capacity of the scale Important Note It is recommended to press the ON OFF TARE key before placing an item on the scale This will help ensure accurate weight readings To turn off the power to the scale 1 Press and hold the ON OFF TARE key for 5 seconds The display will no longer show any weight indicating the scale is powered off LB OZ GRAMS The LB OZ GRAMS key is to switch between weighing Ib oz and grams it is also used for entering into the calibration mode ZERO THE SCALE The proper method of zeroing the scale is to press the ON OFF TARE key MODEL 7010SB TECHNICAL SPECIFICATIONS Construction ABS Plastic Capacity 0 5lb 802 x 0 1 oz 5lb 9oz 9lb x 15 502 x 0 502 0 2500g x 5g 2501 5000 x 10g grams mode Accuracy 2 divisions 0 202 10g 1 002 20g Display Large LCD Unit Size 8 W x 7 5 L x 2 H Platter Size 8 W x 5 L Keypad Membrane switch with ON OFF Tare WT HOLD and LB OZ GRAMS Power Supply 120 VAC 60Hz Ac adapter with 6 power cord or 9 volt battery battery not included CLEANING AND CARE 1 Handle the scale with care Dropping the scale may cause damage to the loadcell which will not allow the scale to weigh properly This type of damage is considered abuse and violates the product warranty 2 To avoid damage to the loadcell never place objects on the scale that exceed 10 pounds 3 Clean the sc