Home

bar codes and stuff help.cdr

image

Contents

1. 231 Taiwan R O C e Tel 886 2 89121122 Fax 886 2 89121810 website www ute com unitech because we care Unitech electronics co 1 Code 39 Full ASCII Code Group 4 Disable Full ASCII Code 39 Enable Check Digit CD Calculate amp Send D not Calculate end Min Length 1 25 Enable CII Ful Code 39 Disable Calculate S Send Double labels decoding off DLS eparator for Double Code 39 Max Length 48 5F No 135 Ln 235 Baoqiao Rd Xindian Dist New Taipei City 231 Taiwan R O C e Tel 886 2 89121122 Fax 886 2 89121810 e website www ute com ESP WIRED CODE READERS gt gt L we BW we ZZ SZA sa Programming Manual International Edition Rev 5 Code 39 Full ASCII Disabled by default Configure Your FuzzyScan Code 39 Code 32 Setting PROGRAM F_DEFAULT Family Code Selection Parameter Selection Option Code Disable Code 39 Enable Code 390 Select Standard Code 39 as primary format 4 Select Ful
2. 9 Full ASCII scan the appropriate bar code below Enable Code 39 Full ASCII Wasp WDI 4500 Disable Code 39 Full ASCII J NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously Code 39 Full ASCII to Full ASCII Correlation is host dependent and is therefore described in the ASCII Character Set Table for the appropriate interface Mas BARCODE TECHNOLOGIES WDI4600 1D 2D Digital Scanner USB Product Reference Guide p Enter Exit Programming Mode Code 39 Code 39 Start Stop Character Transmission Enable this option to enable disable transmission of Code 39 start and stop characters Code 39 Start Stop Character Transmission Don t Transmit Code 39 Start Stop Character Transmission Transmit Code 39 Full ASCII Enables disables the translation of Code 39 characters to Code 39 full ASCII characters Code 39 Full ASCII Disable f Wasp WDI 4600 Code 39 Full ASCII Enable 104 WDI4600 unitech MS840 Hand Held Scanner User s Manual UNITECH MS840 D 7 Code 39 1 2 of 5 5 2 of 5 Code 32 EAN128 Enter Group 7 A Group Default Cx Code 39 0 1 Disable Enable 2 3 Full ASCII Standard 4 Check Digit CD Calculate amp Send 5 CD Calculate not send 6 CD not Calculate 7 8 Send No Send Start Stop 9 Double labels decoding Disable Enable 0 48 Min length 0 Max length 8 4 Check D
3. Code 39 Full ASCII On 1 0 0 2 0 7 Code 39 Full ASCII Off Honeywell MS9520 Symbol LS2208 Product Reference Guide Wand Emulation Interface 9 7 Gonvert All Bar Codes to Code 39 By default the Wand Emulation interface sends data to the attached host in the same symbology that was decoded This can present a problem for customers with older systems that do not recognize some newer symbologies for example GS1 DataBar Enable this parameter to ignore the decoded symbology and output the data as Code 39 Lowercase characters in the original data stream transmit as uppercase his also allows ADF formatting Enable Ignore Unknown Characters to replace any characters that do not have a corresponding character in the Code 39 symbology with a space If you disable Ignore Unknown Characters when the scanner encounters characters that do not have a corresponding character it emits an error beep and discards the data J NOTE ADF Note By default the Wand Emulation interface does not allow ADF rules to process scanned data Enabling this parameter allows ADF rules to process scanned data See Chapter 14 Advanced Data Formatting Enable Convert to Code 39 for Wand Host Disable Convert to Code 39 for Wand Host Convert Code 39 to Full ASCII By default a space replaces any characters that do not have a corresponding character in
4. L C An FuzzyScan System Commands PROGRAM Enter Programming Mode FIN Finish END Exit Programming Mode Factory Default After scanning Factory Default command all parameters will be returned to factory default value Appendix Save User Default User Default System Information List SYSLIST Power Tool Host Link Factory Default Master Default Master Default After scanning Master Default command the scanner will remain the pre set parameters of Host Interface Selection Keyboard Interface Control except Record Suffix Preamble Postamble Serial Interface Control except Record Suffix Preamble Postamble and Wand Laser Emulation Control the rest of parameters will be returned to default value User Default After scanning Save User Default command all current parameters will be stored to the flash memory Once you change the parameter and would like to return to previous setting please scan User Default 84 ESP WIRELESS CODE READERS Honeywell Xenon 1900 1902 Area Imaging Scanner User s Guide Full ASCII If Full ASCII Code 39 decoding is enabled certain character pairs within the bar code symbol will be interpreted as a single character For example V wi
5. RA Technician Bar Code Reading Issues IMCLEAN Within BAR OIS Some users are reporting issues when attempting to read their technician badges with their bar code readers BAR for the OIS program allows shops to source their own bar code scanners and most of the time most brands of scanners will work fine out of the box If you get an error message when scanning your badge that says Badge in Unexpected Format you may need to disable Code 39 Full ASCII quick way to test this is to open up notepad in windows click inside the box and scan your badge If you get a value instead of a E then you should dig out your scanner manual and scan the configuration bar code that disables Code 39 Full ASCII The example below shows a technician badge scanned both ways To the right is are sample configuration bar codes for popular Motorola LS and Ll bar code readers that will allow you to enable and disable Code 39 Full ASCII to test your scanner On the following pages we have supplied configuration pages for some of the most popular scanners we have seen come through our support lines If you have another brand of scanner or you cannot read any bar codes at all we suggest you consult your scanner manufacturer for technical support IMPORTANT You may need to print out the appropriate sheets to scan them with your scanner Example 1 E rror Untitled Notepad Code File Edit Format View Help 39 Full ASCII 0141XXX 11302015 Disab
6. igit CD Calculate amp Send 5 CD Calculate not send 6 CD not Calculate 7 First Digit Suppressed 8 Last Digit Suppressed I 2 of 5 ITF 0 1 Disable Enable 2 3 Fix Length On Off by first three reads F2 2 64 Min length 10 Max length 64 S 251ATA China Postal Code Toshiba Code abe Posti INNI 2 3 Fix Length On Off by first three reads 4 Check Digit CD Calculate amp Send 5 CD Calculate not send 6 CD not Calculate 1 48 Min length 4 Max length 8 Code 32 Italian pharmacy 0 1 Disable Enable F4 2 3 Leading Character Send No Send 4 5 Tailing Character Send No Send Telepen 0 1 Disable Enable 2 3 Standard Numeric Set UCC EAN 128 0 1 disable Enable ll l 2 3 ID disable Enable 4 S ISBT disable Enable will be decoded as Code 128 Define the EAN128 Fields separator ul Scan a ASCII code in full ASCII code chart to select a new Fields Separator Define a separator for double labels hi Scan a ASCII code in full ASCII code chart to select t a new definition of Funcl Min Length Max Length il MII DI hu Z Page D 7 Ini Note If EAN128 be disabled the EAN128 labels unitech because we care Wireless Scanner MS380 User s Manual Version 1 7 Unitech electronics co Itd DE No 135 Ln 235 Baoqiao Rd Xindian Dist New Taipei City
7. l ASCII Code 39 as primary format Select Code 32 PARAF Italian Pharmaceutical as primary format Disable start stop symbol transmission Enable start stop symbol transmission Disable Code 32 leading A transmission Enable Code 32 leading A transmission Disable MOD 43 check digit verification Enable MOD 43 check digit verification Disable check digit transmission Enable check digit transmission Disable Code 39 buffering Enable Code 39 buffering Trioptic Code 39 Setting Disable Trioptic Code 39 4 Enable Trioptic Code 39 Code 39 Min Length Default 01 FIN 01 Maximum 2 digits Il Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Code 39 Family Setting HS Code 39 Max Length Default 98 FIN 98 Minimum 2 digits Scan 2 digits from the option code chart in Appendix then FuzzyScan will terminate this selection automatically Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously E ON W FuzzyScan 14 Appendix Option Codes FIN Finish END Exit 0 0 ps 3 D lun 0 GG 0 2 d 9 OL al L 0 4 Pa N N FL 83 E E CG 2 OL O
8. led Configuration Code most Motorola E0141Xxx 11302015 see other pages for other scanner brand Code 39 Full ASCII disable codes Fixed After scanning Disable Code 39 Full ASCII Enable Code 39 Full ASCII Disable Code 39 Full ASCII Try the barcode below 00h both ways to test Bar code will read D R E W T E C H with Code 39 Full ASCII Disabled GOOD Bar code will read 0 R E thl 7 E As drewtech with Code 39 Full ASCII Enabled BAD Honeywell Voyager 9520 40 Voyager GS9590 Eclipse 5145 Quick Start Guide Aller a www honeywellaidc com pour le francais Val a www honeywellaidc com per l italiano Gehe zu www honeywellaidc com fur Deutsch Ir a www honeywellaidc com para espa ol Para Portugu s acesse www honeywellaidc com br lepewTW Ha pycckOA3bI4HbIM CAUT www honeywellaidc com HAE www honeywellaidc com S gt Sl www honeywellaidc com et www honeywellaidc com OS Sr LIL VG ECL QS Rev C 0 6 12 Expand UPC E to 12 Digits expands the UPC E code to the 12 digit UPC A format Jh nini 3 1 0 7 5 1 5 Expand UPC E to 12 JUNI 3 1 0 7 5 0 5 Don t Expand UPC E to 12 Digits When Code 39 Full ASCII On is scanned certain character pairs within the bar code symbol will be interpreted as a single character For example V will be decoded as the ASCII character SYN and C will be decoded as the ASCII character 3 1 0 0 2 1 7
9. ll be decoded as the ASCII character SYN and C will be decoded as the ASCII character Default Off Q H EE E gt O m gt LI 0 2 6 IO ni m O gt A IO mi m O gt s gt gt 5 gt 3 lt zL L L LIN gt X 5 lt O Z PIA O seso Jero sw S FA U go z mi m E N CC FF SL L FS B B Character pairs M and N decode as a minus sign and period respectively Character pairs P through Y decode as O through 9 0 O ES a Full ASCI On l CIJASCU Full ASCII Off Code 39 Code Page Code pages define the mapping of character codes to characters lf the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see Code Page Mapping of Printed Barcodes on page A 6
10. optic Code 39 and Code 39 Full ASCII simultaneously Code 39 Full ASCII to Full ASCII Correlation is host dependent and is therefore described in the ASCII Character Set Table for the appropriate interface See the ASCII Character Set for RS 232 on page 7 19 or the ASCII Character Set for USB on page 8 18 Code 39 Buffering Scan amp Store Parameter 113 This feature allows the linear imager scanner to accumulate data from multiple Code 39 symbols Selecting the Scan and Store option Buffer Code 39 temporarily buffers all Code 39 symbols having a leading space as a first character for later transmission The leading space is not buffered Decoding a Code 39 symbol with no leading space transmits in sequence all buffered data in a first in first out format plus the triggering symbol See the following pages for further details select Do Not Buffer Code 39 to transmit all decoded Code 39 symbols immediately without storing them in the buffer Wasp WDI4500 Users Manual Transmit Code 39 Check Digit Scan a bar code below to transmit Code 39 data with or without the check digit Transmit Code 39 Check Digit Enable Do Not Transmit Code 39 Check Digit Disable J NOTE Code 39 Check Digit Verification must be enabled for this parameter to function Code 39 Full ASCII Conversion Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set To enable or disable Code 3
11. the Code 39 symbology set Enable this parameter to encode the data sent to the Wand interface in Code 39 Full ASCII In order to do this This setting applies only if ygu enabled Convert to Code 39 the host must be able to interpret Code 39 Full ASCII data Disable Code 39 Full ASCII Conversion Enable Code 39 Full ASCII Conversion Symbol LS2208 DATALOGIC QuickScan Mobile Reference Manual mmm Exit and Save Configuration Enter Configuration hu CODE SELECTION CODE 39 FAMILY disables the family Read the desired family code Read a check digit selection CHECK DIGIT TABLE Standard Code 39 no check digit control gt Datalogic Quickscan M2 check digit control and transmission Full ASCII Code 39 kaan d ocz check digit control without transmission 85 LIJ a Liu CC LL Li CC D 11 32 LI4278 Product Reference Guide Code 39 Full ASCII Conversion Parameter 7 Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set To enable or disable Code 39 Full ASCII scan the appropriate bar code below Enable Code 39 Full ASCII 01h Motorola 114278 Disable Code 39 Full ASCII 00h J NOTE You cannot enable Tri