        Manual - LSS
         Contents
1.    Compact slave   FREEZE  SYNC  AUTOBAUD supported   4 Byte   4 Byte   8 Byte   SPC3   1 Byte  SPC3 specific    1    
2.   The configuration options of PowerSwitch 12 x 20A are situated on the front side  Electricals loads    are connected at the top ofthe device  data ports und power supply at the underside     Inu Load connections                                           34  Load 1 Load 12               mE   e tete o lzbee    PowerSwitch 12x 20A    DMX   Adresse PB   Adresse                 321 10010 1  Address LE              In       Term  321  Address j   LED  LED    DMX Profibus ower supply    LSS f    PowerSwitch 12 x 20A    Data Ports    DMX    The DMX port is optically isolated and has an extensive EMC filter  DMX is connected as shown in  the table           Data    Data    GND                   Profibus    Profibus is supplied via M12 connector  male  amp  female  and forwarded  Using pre assembled ca   bles can save a lot of time during the installation of several power switches next to each other  The  cable shield is loop through the metal sleeve     PIN Assignment          fe 2  NC  eee    oH XE  M12 B vem M12 B male  1 2 3 4 5  not connected A  green  not connected B  red  not connected                         The Ground is looped on the metal sleeve     Baud rate    The PowerSwitch 12 x 20A support Profibus DP  Decentralized Peripherals  with full baud rate  A  standard GSD file is available     PowerSwitch 12 x 20A    Power Supply    The switch actuator requires 24V DC  which must be connected to the 3 pin 5 08mm terminal        3 2 1  PE GND    24V                      The c
3.  1x Profibus signal present  data exchange impossible     false address  address not included into the master   cable A B reversed                    Blinking 1x Hardware failure  module is defective   Blinking 2x Parameterization error  Check master programming   Blinking 3x Configuration error  Check master programming   Blinking 4x Hardware failure  module is defective   Permanently on Data exchange ok  Profibus ok  no watchdog  HOLD    active in case of data loss       On and flashes at 1s time    Data exchange ok  Profibus ok  watchdog ok  in case  lag of data loss all data will be erased                In addition  the following condition can occur        DMX and Profibus LEDs CPU clock incorrect  PLL error  due to extreme dis   flashing quickly turbances in the power supply or hardware failure   PowerSwitch 12 x 20A is defective                LSS d    PowerSwitch 12 x 20A    Configuration    Priority of Data Signals    PowerSwitch 12 x 20A can receive DMX and Profibus signals simultaneously  The Profibus has al   ways priority over DMX when the device is in the state of data exchange  This means there is no  merging of data     Certain Profibus global control commands during the Data Exchange  e g  PLC in STOP  cause an  Off of all relays or  if HOLD is set  holding the last relay position     Without Data Exchange the control is on DMX  If the DMX signal is missing and depending of the  HOLD settings  all relays are turned off or holding the last state  Is the incomi
4. 0 V AC   10 kVA   15 kVA  1500 V eff     PowerSwitch 12 x 20A    Switching capacity   Filament lamp  4800 VA  Luminescent screen tabs uncomp   5000 VA  Luminescent screen tabs parallel comp   2500 VA   200 uF  Halogen lamp  230V AC   5000 VA   Low voltage halogen lamp with transformer  2000 VA  Sodium mercury vapour lamp  5000 VA   Dulux Compact Luminescent screen tabs uncomp   4000 VA    Dulux Compact Luminescent screen tabs parallel comp   3000 VA   200 uF     Information for 30 000 operations     DMX    Number of Inputs     Electrical isolator   Isolation volate    EMC    Standards    Baud rate    Start code    Minimum protocol length   Maximum protocol length   Minimum cycle delay   Maximum cycle delay   Reception timeout     Max  distance between 2 packets     Minimum realized break length   Maximum valid break length     1   Isolated ANSI E1 11 A1   Optocoupler   1000V DC   Filter switching   USITT 1990  DIN 56930 2  ANSI E1 11  250 kbps   0   Start code only   Start code   512 values  values over 512 will be lost   44 us   22 5 ms   2s   2s   48 us   1 95 s    LSS t    PowerSwitch 12 x 20A    Profibus    Supported Baud rates   Station address   TSDRmin   PNO Identnumber   GSD file    Diagnosis    Slave type    Slave character   Length output    Lenght input     Summary of Input Output bytes     Profibus chip   Length user parameterization   Number of modules     9 6 kBit s   12 MBit s  0   126   11 Bit times   OC51h   available   1 Byte external diagnosis  parametrical
5. 16  dog m                                               16  AEMERRIDIONIRUU UII LII LOT 16  Switching  capacity    nennen EE ERE VERE EYE ERE CEE RELY VERRE EXTERN RE ERER 17  bp d                                              17  Profibus ETE TID LIRE 18    LSS 3    PowerSwitch 12 x 20A    Introduction    How to use this manual    This manual provides advices and information   s about the function and configuration of the Pow   erSwitch 12 x 20A     Like all devices of LSS GmbH the PowerSwitch 12 x 20A is constantly evolving technology  It is  therefore possible that this manual does not explain later development forms     This manual uses the following symbols to indicate important information for your safety and for  configuration     Here you get additional information   s     Attention alerts you to situations in which decisions can provoke to technical  problems with the equipment or losing data     A Warning statement indicates situations in which can result in injury or dam   age to life and limb      gt   gt        Safety advices  Proper care of the PowerSwitch 12 x 20A is not dangerous  However please note the following     Authorized personnel must install the device     Never operate with visibly damaged devices     If the suspect prior to a defect  immediately disconnect the device from the power  supply  Secure the device to restart     Employees of the LSS GmbH may only make repairs     PowerSwitch 12 x 20A    Instructions fore use PowerSwich 12 x 20A    The Pow
6. LSS    PowerSwitch  12 x 20A       Twelvefold switching actuator 20A  4600VA  for  DMX512 and Profibus    User Manual    LSS GmbH www lss lighting de  Am Eichenberg 1  04600 Altenburg Tel    49 3447 835500 Fax   49 3447 861779  Warnem  nder StraBe 1  01109 Dresden Tel    49 351 79565690 Fax   49 351 79565699    PowerSwitch 12 x 20A    Date  09 01  2013    All rights reserved  No part of this publication may be reproduced in any form  print  photocopy   microfilm or any other process  or reproduced by using of electronic systems  copied or distribut   ed without the written permission of the LSS GmbH     The LSS GmbH is not liable for damages  losses  costs  and changes that have been made by unau   thorized persons  This manual has been prepared with great care  Liability for negligent errors  e g   misprints  is excluded     All mentioned names of products in this manual are trademarks of their respective companies   From the lack of trademarks       and     can not be concluded that the name is a free brand name     PE 8    PROFIBUS    PR    The Licht   Steuer  und Schaltanlagenbau GmbH is certified member of the Profibus User Organiza   tion PNO     Technica    andards   N Program  era    The ESTA Manufacturer ID of Licht   Steuer  und Schaltanlagenbau GmbH is   LS     76 83    4Ch 53h         2013 LSS GmbH    PowerSwitch 12 x 20A    Index   Introduction m                                                      4  How to use this man  alssssisisssentinnisin aE a aa a SaS a ao
7. be activated in two ways for Profibus failure   1  With response  When response is active  the green Profibus LED flashes unsteadiness     When response is not active  so HOLD is active   the green Profibus LED flashes  permanently     2  With the larger Profibus addresses  2 80h    At the input must be applied no DMX signal   The Profibus data will be hold in the DMX memory     Simatic STEP7    Watchdog  its a checkbox at the Profibus settings  GSD file  Copy the GSD file to     STEP7 S7DATA GSD  Bitmap file    Copy the Bitmap file to     Step7 S7DATA NSBMP    Update the catalogue  The PowerSwitch 12 x 20A appears in  Profibus DP   Additional Field Devic   es   IO   LSS      LSS 13    PowerSwitch 12 x 20A    Appendix A    Technical Data    General technical data    Design type   Setting elements   Dimensions   Power supply   Quiescent current   Operation current   Electric consumption   Weight    Security standards   RoHS conform   Order number     Ports    Profibus    DMX    24V   Schaltausgange     Relays    Switch contacts    Minimum mechanical circle   Maximum switching current   Maximum switching power     Maximum switching capacity     Proof voltage     housed hardware module for DIN Rail  rotary switches   BxDxH inmm  217 x 63 x 90  10   30 VDC   0 1A   2 0A   2W   0 8kg   IEC EN 60950  UL cUL 1950  File E141988   yes   5048    Binder Series 766 5 BU LP und 5 ST LP  Phoenix MKDSN1 5 3 5 08   Phoenix MKDS2 5 3 5 08   Phoenix MKDS5 2 7 62    AgSnO   1 000 000   20A   44
8. dai 4  SITELV AV M ENT E     E  4  Instructions fore use PowerSwich 12 x 20A Qo     ccecccessesssececeeeceeesseeaecececeeesnesesasseeeeeessesseeeaeeeeeeeeesaes 5  Typical applicatlolis anna 6  Typical applications of the PowerSwitch 12 x 20A                 esses eene nnne nennen nnns nnn nene 6   a nein et                          7  Ports and Operaltlfig nee een Eve d lei n 7  Device OVOrVIGW        eio Ser EE ERR NH EIRR TNI ER ENRENE EIRRS PE RE SEA YRR MER sees SR SERT RENE RE re RE SEEYRR ERRARE DRSENFUERRRRR NUS E 7  Ibi Hoja 8  Power SU IY eme                                                      9  ASENET se ee ee ee Eee 9   LED FEDOMNS tM 10  OVERVIEW                                               10  odio Mc                       C 10  Profibus ize 11  sop D pr C                                             12  Priority of Data Signals  IM EE 12  DMX Settings  anime   M EESR P RERRAENE a MBA ide RT 13  DMX ads menie onte E E E een irse EINEN ORUEREERE RE EPA re Tr ET LUE 13  DMX Signal  rrt rir rte E Ue ED e EHE nennen einen 13   Sel test   oodd eem MIR MS 13  Profibus SettiliBs uch 14  Profibus address    obe ie irri o ea ea Ta e a a ET EE RE a iaaa 14  Profibus CEFM IN Atl OM isassecsecess rtc re et nike siehst nen E 14  Profibus signal      rene a re HR REE EE E EER 14  ApDendb A  ne ee E E E ee 16  Technical Data     rere an lu 16  General technical data          c ccccccccccssssssscececeeeceesesseaeeececeesseesesaeaeeeeeeesesseseeaeseeeeseessesesaeaeeeeeeeeeeses 
9. erSwitch 12 x 20A is designed for continuous operation  However please note the follow     ing     e Use the device only for its intended purpose      N e Avoid extreme mechanical loads   e Avoid direct exposure to moisture and excessive heat on the device     LSS    PowerSwitch 12 x 20A    Typical applications    Typical applications of the PowerSwitch 12 x 20A    The PowerSwitch 12 x 20A is a switch assembly with bistable  poled relays in a compact de  sign   With it up to twelve independent resistive  inductive or capacitive loads can be switched  Each  channel can supply loads up to 4600VA at 230V  Every switching status of each channel can be  read directly on the switch actuator     The input control of the PowerSwitch 12 x 20A is done with Profibus  IEC 61158   IEC 61784  or  DMX512  So the switching actuator supports the two most popular control protocols in lighting  and wiring installation  The PowerSwitch 12 x 20A is also equipped with a comfortable configura   tion  The front panel configuration switches will be set the DMX   Profibus start addresses  the  switching behaviour at DMX signal loss and the termination of Profibus  In addition  the switching  relays can also be switched manually directly on the device     The PowerSwitch 12 x 20A is designed for installation in electrical control cabinets and junc  tion  boxes  For that he is equipped with a socket for DIN rail     PowerSwitch 12 x 20A    5    Functional survey    Ports and Operating    Device overview
10. ng DMX signal  switched off the DMX timeout of 2 seconds take effect     If the device is switched off and on again  the last switching state will be received for the first 3  seconds after the switch  Is HOLD active and none of the two input signals is present  the switching  state is also obtained in addition  Otherwise  the relays will be switched in depending of the input  signal or switched off when no input signal is present     PowerSwitch 12 x 20A is not able to detect the switching state of manually switched relays itself   These relays maintain their switching status until they are contacted directly by changing  their   bit or DMX circuit     PowerSwitch 12 x 20A    DMX Settings    DMX adress    Three decimal rotary switches sets the DMX address   From left to right  100  10  1    Only addresses from 001 to 501 and test addresses m901 to 904 will be evaluated  All other ad   dresses are invalid and their DMX data will be ignored     DMX signal    PowerSwitch 12 x 20A uses the 12 circuits from the set address  Is the incoming value 25096  2128   the relay is switched on  The timeout when no input signal is present is 2 seconds  Faulty protocols  will be ignored     HOLD can be activated by using a higher Profibus switch  address 2 80h   The description of this  follows in the  Profibus settings     Self test    A self test can be activated with the DMX addresses 901 to 904   901   On Off test of all relays with about 1 second  902   On Off test of all relays with ab
11. out 60ms    903   Running light with about 1 second  904   Displays the firmware version with relays  1   1  2   2 etc       N Never run the self test with connected loads     LSS 12    PowerSwitch 12 x 20A    Profibus Settings    Profibus address    Two hexadecimal rotary switches set the Profibus address   From left to right  10h  1h    The addresses OOh to 7Eh are evaluated for Profibus  Addresses 80h to FEh are evaluated just as  the addresses OOh to 7Eh but in addition  the HOLD function is activated     Example  Setting    0       4      DP address 04h  4 decimal   Setting    9       C      DP address 1Ch  28 decimal  and HOLD active  Profibus termination  Is PowerSwitch 12 x 20A located at the end of a Profibus bus segment  a slide switch can terminate  the bus   Profibus signal    The PowerSwitch 12 x 20A uses 4 Byte Out and 4 Byte In  4DO  ADI   Parameter setting is not nec   essary  GSD file and bitmaps are present        1 0 Byte   Bit Meaning  Out 0       Relay switching Bits 1   8       Relay switching Bits 9   12  Reserved       Reserved       Reserved  Relay Feedback 1   8  Relay Feedback 9   12  reserviert  2 3 1 word DMX diagnoses  set DMX address  0   999    1  DMX task is running  13   14   Both  0  DMX signal is not present  Both  1  DMX Signal ok  Or else frame error   polarity reversed wire          5  Polojoo  5o o  Mo  MISSIS Uo         e oO  M3  r  r    15 HOLD active  3 0   7 Relay Feedback 1   8                      PowerSwitch 12 x 20A    HOLD can 
12. urrent consumption of the PowerSwitch 12 x 20A in rest is about 70 mA  in the switching with  all 12 relays for the duration of the switching pulse about 2A  The switch pulse is about 30ms  The  maximum switching rate is about 60ms  30ms pulse  30 ms off      Relays    The load is connected to 7 62 mm terminal strip  As shown in the image  two adjacent terminals  are the closer of one relay  The following image shows the switching status of a relay        Off On                   LSS 3    PowerSwitch 12 x 20A    LED reports    Overview    The LEDs have the following meanings from left to right                                   LED Colour Meaning  DMX Green DMX reports  see below  Profibus Yellow Profibus is in data exchange  Profibus is running  Profibus Green Profibus reports  see below  Power Green 24V DC power supply ON  DMX LED    DMX LED shows following reports                       Signal Meaning   Off No incoming DMX signal present   Short time flash DMX test adresses 901   904 are adjusted   Cyclical flash Incoming DMX signal incorrect  Data       reversed   wrong timing or level  false start code  or incoming  RDM signals   Permanently on Incoming DMX signal  HOLD is not active   On and flashes at 1s time    No incoming DMX or Profibus signal present  HOLD   lag is active                PowerSwitch 12 x 20A    Profibus LED    The green Profibus LED indicates the following reports              Signal Meaning  Off No Profibus signal present  A B reversed    Short flash
    