1. Zz 2 1 Pulse inputs The following pulses are available e Potential free reed pulse voltage 2 6 to 3 6V via M Bus standard e SO pulse according to DIN 43864 only with AC or DC supply voltage optional The register overflow happens from 2 147 483 647 conforms to 7FFFFFFF hexadecimal to 0 Reed Inputs S0 Inputs S0 Inputs without supply Option 1 15VDC 24VDC Option 2 230VAC or 115VAC voltage 9e Input1 pee Input E Input1 Input2 inpute Input2 ps Eget xe oe pile PF tcr EREE E e EE EE baer pa JE E M BUS LOG Em M BUS LOG MON id M BUS LOG Ben 7 CLP as m was eut SE U ESE E r Tr r EE ER III Option E Tre 15VDC M Bus T M Bus 24VDC u u U UU Option 230VAC M Bus Mix Mix Option 1 Option 2 Input1 1 Input1 A Input Input2 le sllelelelelslele IS e Les HESSE E is mer MBUSLOG La Pr 7 M BUS LOG X ERES s M BUS M BUS tee pOocccooc Option p M n 15VDC M Bus T eee 24VDC Option i I I I L gin M Bus M Bus Logger OBE 2 2 LED Displays The functions of the M Bus Logger are displayed by
2. 11 M Bus Logger Zz Subject to change without notice
3. M Bus Pulse logging Reed yes Load profile with time stamp Reed Inputs without M Bus Input1 N Input2 Pulse logging Reed yes Load profile with time stamp S0 Inputs with supply voltage with M Bus active Input1 Input2 lellelele Ere M BUS LOG Option 230VAC M Bus Pulse logging S0 yes Pulse logging Reed yes yes no Load profile with time stamp yes S0 Inputs S0 Inputs S0 Inputs without supply voltage with M Bus active Input1 Input2 ki lel l lelel l PEPE faer M BUS LOG ceu I H EES E TW TII L M Bus Pulse logging S0 no Pulse logging Reed yes Load profile with time stamp yes with supply voltage without M Bus Input1 pu elels ale e M BUS LOG Option 230VAC Pulse logging S0 yes Pulse logging Reed yes Load profile with time stamp yes
4. M Bus Logger 2 mu DIET M Bus Logger The M Bus Logger has a modular design in top hat rail installation The following options are available changeable vie parameterization software e Load profile 4000 values ca 40 day with 15 min registration period e Billing data for 16 resets e g 16 month values For both option the date will be saved by 8 digits with time stamp Programming and data retrieval by M Bus according to DIN EN 1434 3 The following device types are possible e Reed Inputs without supply voltage includes internal Lithium Battery e SO Inputs Option 1 with supply voltage 15VDC 24VDC e SO Inputs Option 2 with supply voltage 230VAC or 115VDC Reed Inputs and Option 1 Option 2 wan 99 DOUM eccc2299 CS soz R2 R2 s01 sp Rie R1 mber I M BUS LOG M BUS LOG M Bus wes 3 pn C Bo pn CE Bs iS M BUS CT han emeng M US W BUS s ww Figure 4 Device type ww This description includes all types of the device M Bus Logger
5. without supply voltage without M Bus Input1 Input2 Bi lelelelelelel E 4 M BUS LOG A 4 4 A Pulse logging S0 no Pulse logging Reed yes Load profile with time stamp no M Bus Logger Zz 3 Technical Data Housing top hat rail installation Degree of protection IP20 Dimensions W 2 35 1 mm Option 1 or 70 2 mm Option 2 H 90 mm D 58 mm Protection class 2 Auxiliary power M Bus max 3mA via M Bus 2 M Bus standard load Battery Type Lithium 3 6V necessary for load profile Lifespan ca 8 years without M Bus connection Supply voltage None Reed Inputs only optional possible for SO Option 1 15VDC to 24VDC S0 and Reed pulses only Option 2 230VAC SO and Reed or 115VAC Interface M Bus passive according to DIN EN 1434 3 Baud rate 300 2400 default 9600 or 19200 Baud 8E1 Software interface According to IEC 60870 5 primary or secondary addresses Pulse inputs No 2 Type Reed all versions or S0 Option 1 or 2 only Pulse frequency max 12Hz pulse length 40ms minimum Option 150Hz pulse length 0 05ms break 5ms Pulse input reed Potential free min 1MQ isolation Capacity 2nF incl cable Resistor open 1 MO close lt 2kQ Voltage 2 6 to 3 6V Curren
6. Zz M Bus Logger Data Logger User Manual Doc No E102312514074 w w w w w KREE ww B r Industrie Elektronik GmbH Rathsbergstr 23 D 90411 N rnberg Phone 49 0 911 970590 Fax 49 0 911 9705950 Internet www baer gmbh com M Bus Logger Z COPYRIGHT Copyright 2014 Z527 BAR Industrie Elektronik GmbH All rights including those originating from translation re printing and copying of this document or parts thereof are reserved No part of this manual may be copied or distributed by electronic mechanic photographic or indeed any other means without prior written consent of Z BAR Industrie Elektronik GmbH All names of products or companies contained in this docu ment may be trademarks or trade names of their respective owners Note Based on its policies ZZ BAR Industrie Elektronik GmbH develops and improves their products on an ongoing basis In consequence Zee BAR Industrie Elektronik GmbH preserve the right to modify and improve the software and hardware products described in this document Specifications and other information contained in this document can change without prior notice This document does not cover all functions in all possible detail or variations that may be encountered during installation maintenance and usage of the software Under no circumstances whatsoever will Zee BAR Industrie Elektronik GmbH accept any liability for mistakes in this document or fo
7. two LED s LED Function Description o M Bus Dimly lit M Bus on line galaw Blinking light Data communication via M Bus Error Permanent light Permanent error Data error in the measurement red memory EEPROM Action The M Bus Logger must be sent to the manufacturer for service Flash Measuring period at the begin of new measur ing period e g every 15 min the Error LED flashes for one second 2 3 Parameterization The device can be programmed via the die M Bus interface according to DIN EN 1434 3 with the software MBusLogSet It provides following func tions e Set date clock baud rate device address register value etc e Read configuration e Read data n n EL MBusLogSet 2 00 Comi 9600 B File Equipment Settings Info lo MM Addressing Device address Ex i i NE primary 0 255 z Initialisation OK n Configuration Change primary address SS Paa fi 1 132 kwh Change secondary address Input 1 nc Counter value lad s Write configuration Change baud rate Input 2 IN IV Counter value 89413901 kwh gt Read data Adjust equipment clock Option Medium Other Load profil Pies Registration period 15 min z C Billing data IV With summer time switching 10 40 02 42 16 ES 10 7B 02 7D 16 68 D D 68 08 02 72 45 50 09 00 25 08 23 00 00 00 OO OO 84 CO 80 00 06 84 00 00 00 C4 CO 80 00 06 84 00 00
8. 00 84 C1 80 00 06 84 OO 00 00 C4 CL 80 00 06 84 00 00 00 84 C2 80 00 06 84 00 00 00 C4 C2 80 O0 06 84 00 00 00 84 CH 80 00 06 84 00 00 00 84 80 CO 00 06 OD 59 54 05 C4 80 CO 00 06 OD 59 54 05 84 81 CO 00 06 OD 59 54 05 C4 81 CO DO 06 OD 59 54 05 84 82 CO 00 06 OD 59 54 05 C4 82 CO 00 06 OD 59 54 05 84 83 CO 00 06 OD 59 54 05 84 80 80 00 6D 1C DE SE 1B C4 80 80 00 6D OF OE SE 1B 84 81 80 00 6D 00 DE SE 1B C4 81 80 00 6D 2D OD SE 1B 84 82 80 00 6D 1E OD SE 1B C4 82 80 00 6D OF OD SE 1B 84 83 80 00 6D 00 OD SE 1B IF 01 01 01 01 01 15 00 1F 01 04 CC 16 Clear buffer sa Quit Tool for installation of M Bus Logger OFFLINE 30 11 2010 14 28 08 k 4 Figure 5 Parameterization program MBusLogSet DIET M Bus Logger Factory settings for M Bus Logger if not differently ordered e Baud rate 2400 Baud 8E1 e Primary address 0 e Secondary address serial number 8 digits e Option for data storage load profile registration period 15 minutes 2 4 Data Storage Bus Logger consists following components needed for internal registration memory e Internal Lithium Battery e M Bus voltage active ca 36VDC Note For option 1 with supply voltage 15VDC to 24VDC is for re cording of load profile the M Bus voltage needed e Optionally supply voltage Reed Inputs with M Bus active E Input1 A Input2 el fsa EENEI
9. by operators supplying numerous consum ers e g industry and technology parks trade fairs building managements etc M Bus Structure An M Bus system consists of user specifically configurable and task specif ic system components and different repeaters that are grouped together in one or more segments via a simple twisted pair cable The structure of an M Bus segment can be designed as a e Star structure e Linear structure e Tree structure M Bus CI M Bus BE NY a G M Bus w q Figure 1 M Bus segment M Bus DIET 1 3 M Bus Logger Each segment is terminated with a repeater and connects up to 250 termi nals Repeaters can be cascaded i e segments can brunch to lower level segments The control centre of an M Bus system is formed by the M Bus master It consists of an M Bus repeater connected to a normal commercially availa ble PC RS232 m M Bus Master M Bus INN M Bus Repeater M Bus Figure 2 M Bus structure Communication Data transfer at the M Bus is executed serial as Master Slave operation via M Bus master or mini master with RS232 interface to PC slelsls PPPE EEFE RS232 M Bus M Bus Master M Bus Logger Figure 3 Communication A two wire standard telephone cable e g JYStY N 2 0 8 mm or better is used as the transmission line for the M Bus
10. cy ca 119A Pulse input SO Option According to DIN 43864 Adjustment 1 255 1 255 Measuring period 1min to 24hours Real time clock max deviation 30 sec month at 25 C 10ppm Data storage Load profile max 4000 values Billing data max 16 resets LED 2 LED s for Error and M Bus Extent of delivery M Bus Logger with 2 Reed Inputs Optional Power supply for AC or DC 2 pulse inputs for SO pulses Order Number 11913 2 Reed Inputs without supply voltage 12405 2 SO Inputs supply voltage 15VDC to 24VDC 11792 2 SO Inputs supply voltage 115VAC 11821 2 SO Inputs supply voltage 230VAC Accessories M Bus Master Repeater Mini Master Cable Software MBusLogSet AMR Software e g SIGLON 10 OBE M Bus Logger 3 1 Dimensions k 351 y le 70 2 gt k 58 N q m n m H n n n m n m H SS E x ce lee PIPIPIBIBIBIBIE PPPE gog GedggolGgG p S02 s02 R2 R2 4 S02 so2 R2 R2 4 E an len R Ta Lan s01 Ri Ri 7 Ut Error baer Ser S M BUS LOG M BUS LOG M Bus M Bus 20 CE E w0 S v2 po C 2010 2 v2 M BUS M BUS M BUS M BUS 230VAC 230VAC M BUS M BUS 230VAC 230VAC M BUS M BUS POOE PUMA PIPPE PIFIFIF E E ETE P
11. r any sub sequential damage arising from installa tion or usage of the software Zee BAR Industrie Elektronik GmbH preserves the right to modify or withdraw this doc ument at any time without prior announcement Aser BAR Industrie Elektronik GmbH does not accept any responsibility or liability for the installation usage maintenance or support of third party products Printed in Germany Zz M Bus Logger Table of Contents NR e sa dakaaksauaha 4 SN NN E cm 4 1 2 M Bus Siruciur Sr 4 d Oompmbll Celo uu uuu uuu nunana nanus dU RITE E b 2 M B S LOgger u T 6 MEL e n M 7 22 EED DISpla M 8 23 NEE e E 8 2 4 Data SI0 8g u RANA KANA NAAANINAG 9 3 Technical Data c 10 3 1 DIMENSIONS uuu u M UN 11 M Bus Logger 1 1 1 2 Zz General M Bus The M Bus system is a data transmission system for acquiring evaluating optimizing and controlling energy and process data Modular components permit networking of a large number of different energy meters and com puter controlled terminals The high degree of noise immunity even in noisy environments ensures reliably and error free measured value trans mission Via modem interfaces it is also possible to cover large distances to connect modular expansions or complex substation systems The M Bus system is the system preferred