1. A steady light indicates that the zone is currently activated This gives you the facility when leaving your home to check if any windows or doors were left open MAINS FAILURE indication MAINS This indicator will be on to indicate that either there is an AC power failure or that the transformer supplying power to the system has been accidentally unplugged SYSTEM BATTERY LOW indication BCKUP The system s battery is left with only 80 of its nominal capacity Check mains WIRELESS DETECTOR BATTERY LOW TAMPER indication WL TBL This light will be activated by poor condition of the battery in the wireless sensor shown by the digit display Change the battery in the sensor indicated SYSTEM ARMED indication This light is on whenever the system is either armed or set on warning mode TRIGG SYSTEM TRIGGERED indication This flashing light warns you that an alarm activation has occurred while you were away ENTRY EXIT DELAY indication It is often required that some of the zones activate only after a preset time delay This is done DELAY when you the user would like to keep the arm disarm REMOTE CONTROL in the house rather then carrying it around at all times This light will warn that you have initiated a time delay on one of the zones and that you have a limited time programmable to reach the REMOTE CONTROL or the KEY PAD and disarm the system SYSTEM RUNNING indication RUNNG This light reassures you that the sy
2. Every time one of the users arms disarms the system the new condition is FEE to the Er room MULTIPLE ENTRIES ARE ALLOWED 2 2 2 2 1753 5 A ONLY WITHIN ALLOWED MASK IN MULTIUSER SET TO WARNING YELLOW LEDS 2 2 2 2 A B 3 3 3 HH e 8 gt Ho Fe o X3 X3 X3 Q3 X3 Xs X3 Os ARM PRESET PATTERN D a Aa Xd Xa Xa ka Xa xa Xs Xs Xs Xs CHANGE CODE OF USER 2 2 2 2 EXISTING USER 2 CODE HOLD NEW CODE 4 DIGITS THE NEW CODE WILL BE PLAYED BACK ON THE DISPLAY al TILL BEEP PRESS TO ACCEPT THE NEW CODE ANY OTHER KEY WILL ENTER E NEW CODE CHANGE CODE OF USER 3 3 3 3 3 EXISTING USER 2 CODE o a amp amp CHANGE CODE OF USER 4 4 4 4 4 EXISTING USER 2 CODE CHANGE CODE OF USER 5 5 5 5 5 EXISTING USER 2 CODE co TILL BEEP X00329 6 SUPER TRACER USER A5 2 CDR Your SUPER TRACER Security System zone description and pattern allocation Premises There ZK NAGHT working zones on your alarm system Th amp NHIGHT zones correspond to the following areas in the house ZONE 2 ZONE 6 ZONE 3 ZONE 7 ZONE 4 ZONE 8 Zone allocation for each level mark with a cross ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 Level A Level B L
3. system to the respective level a b c or d If an exit delay had been programmed you have a preset time to leave the premises pressing 1 will shorten the delay DIS ARMING YOUR SYSTEM user code e g 1111 All zones will be dis armed if an entry delay had been programmed you have preset time to enter the premises and disarm the system SELECTING THE WARNING MODE preset levels user code the level required B e g 1111 a B Warning preset level a Individual zones user code the zones required B e g 1111 1 2 3 5 B Warn zones 12385 quick warning mode Press and Hold buttons and either A B C or D to Quick Warn mode the system to the respective level A B C or D GENERAL Notes 1 Both entry and exit delays will be indicated by an intermittent bleeper if so selected 2 Running LED S on the display indicate zones being monitored 3 Steady LED S on the display indicate permanently armed zones 4 To silence battery low and mains failure bleeper hold 0 until the bleeper is switched off 5 Pressing these 2 keys simultaneously will cause the following signals to be activated and will activate a panic signal 7 and 9 will activate the lights 4 and 6 will activate the transmitter for a test transmission PLEASE TEST YOUR SYSTEM REGULARLY at least once a week WITH THE CONTROL ROOM X00329 2 SUPER_TRACER_USER_A5 2 CDR Arming by Users 1 2 3 amp 4 a
4. MANUFACTURING AND MINOR INVENTIONS SUPER TRACER user manual X00308 MAY 2006 SUPER_TRACER_USER_A5 2 CDR OPERATION After the installation completed the remote KEYPAD DISPLAY S should indicate the following Note Some of the warning yellow lights may temporarily be ON to indicate that some of the zones doors windows or motion detectors are still activated or settling down i ARMED indication OFF PERIMETER indication OFF WARNING indication OFF MAINS indication OFF SYSTEM LOW BATTERY indication OFF LOW BATTERY in sensors indication OFF SYSTEM ARMED indication OFF E MAINS BCKUP WL_TBL TRIGG and DELAY TRIGGERED indication OFF indications can individually be made to beep DELAY indication OFF together with the corresponding display RUNNING indication FLASHING m This can only be changed by the installer Note ARMED ZONES 1 TO 8 The RED lights indicate which of the zones are armed A steady light indicates that the zone is permanently armed 24 hrs A running light indicate which zones are being monitored for an alarm condition PERIMETER SECTORS 1 TO 8 The GREEN lights indicate which of the PERIMETER sectors are in warning mode WARN ZONES 1 TO 8 The YELLOW lights indicate which of the zones are in warning mode The running lights indicate which zones are being monitored for a warning condition
5. ature of MULTI TRACER is its ability to operate in MULTI USER or ZONE SHARING mode This option is set in the option register 1 Page 8 This mode allows up to 4 users to independently operate the same control panel and accessories In this mode USER 1 who normally has special rights is replaced by a user 5 who has the same rights as users 2 3 and 4 USER 6 7 8 9 amp 10 are not available in this mode Understanding how the zone sharing concept works is simple just remember the following Assume that users 2 and 3 are sharing some zones To DISARM shared zones think of the OR function e g EITHER user 2 OR user 3 can disarm To ARM shared zones think of the AND function e g BOTH user 2 AND user 3 must arm It is possible to provide each user with a specially coded remote control Ask your installer about it EXAMPLE USER 2 HAS ACCESS TO ZONES 2 3 and 4 in common with user 3 USER 3 HAS ACCESS TO ZONES 6 7 and 4 in common with user 2 ZONE 4 can be activated only ifuser2 AND 3 have armed it but can be deactivated either by user 2 OR 3 OPERATION USER CODE 2 2 2 ARM PRESET PATTERN B 2 DISARM PRESET PATTERN B gt 2 2 2 2 ARM PRESET PATTERN C DISARM PRESET PATTERN C DISARM PRESET PATTERN D ARM PRESET PATTERN A 4 DISARM PRESET PATTERN A gt X Xs C3 Xe 1
6. em S P I An extra 8 perimeter beams can be connected to the new SUPER Tracer Combo The unit will monitor these perimeter beams and indicate which beam was triggered The activation of the beams will only sound locally and will not report the activation to the control room The perimeter beams can be armed by following this procedure Note For this feature to work correctly you need to do the following Ne w I 1 The beams used must be programmed and be functional aligned SE 2 The SPI System option must be enabled by the installer page 10 3 The number of active sectors beams must be programmed by the installer page 10 gt 1h gt 10 gt h lt i i l ARM PERIMETER SECTIONAL BEAMS gt 4 4 1 4 0 1 3 mu SET SENSITIVITY LEVELS Domm 9 2 1 m FOR EACH SECTION USER1 CODE Device Level NO Use the table to select the level interruption time before alarm WIRELESS ZONE SUPERVISION TEST Please note Both the Wireless Zone supervision option Pg 8 and the active wireless zones pg 10 eed to be enabled by the installer before this function will work correctly The SUPER TRACER is capable of reporting a faulty wireless detector To display the faulty non reporting wireless detector press and hold the key until it beeps WIRELESS ZONE SUPERVISION a ee a er ee ee ae etS fmt Beep 2OO 26 6 An F i
7. er 1 you can enable or disable Auto arming If enabled 15min or 2 hrs after the zone 1 was last triggered the system will arm automatically ENABLE AUTO ARM Nan A HOLD BOTH VV TILL BEEP im DISABLE AUTO ARM 1 1 41 1 Ad HOLD BOTH z TILL BEEP lt NOTE THIS OPERATION WILL SHOW A 1 ON THE DISPLAY NOTE THIS OPERATION WILL SHOW A 0 ON THE DISPLAY 4 X00329 a SUPERTRACER A5 UM 2 CDR LIST OF USEFUL QUICK SINGLE AND DOUBLE KEYS QUICK WARN LEVEL A TLL BEEP QUICK ARMING LEVEL A Be QUICK WARN LEVEL B Tue BEEP QUICK ARMING LEVEL B goes QUICK WARNLEVELC gt C Horo gor QUICK ARMING LEVEL C nii BEEP QUICK WARN LEVELD gt gt D maser QUICK ARMING LEVEL D D mises HOLD BOTH PANIC ACTIVATION gt x GE irase WIRELESS SUPERVISION REPORT gt 4 SEND TEST TRANSMISSION 4 6 ures WIRELESS DETECTOR SUPERVISION REPORT Please note This function will work correctly only if both SWITCH LIGHTS ON OFF gt 9 TLL BEEP the Wireless Zone supervision option Pg 10 and the active wireless zones have been enabled by the installer HOLD BOTH MEDICAL 1 TICE BEER 7 An F for Faulty is shown on the display Sy Bd NR amp wu w y 38 8 N NN _ N N SECTIONAL PERIMETER INTRUSION Syst
8. evel C Level D Perimeter There are also EIGHT optional perimeter sectors on your alarm system These EIGHT sectors correspond to the following SECTOR 1 SECTOR 5 SECTOR 2 SECTOR 6 SECTOR 3 SECTOR 7 SECTOR 4 SECTOR 8 Perimeter sector allocation for each level mark with a cross SECTOR 1 SECTOR 2 SECTOR 3 SECTOR 4 SECTORS SECTOR 6 SECTOR7 SECTOR 8 Level A Level B Level C Level D MANUFACTURER S NOTE Congratulations You are now the owner of one of the most sophisticated and featured alarm systems in South Africa The SUPER TRACER system has evolved over the last 15 years during which time the STATE OF THE ART technology was continuously applied and manufacturing perfected This latest model has been developed with the End user insurance companies and corresponding armed response pre requisites in mind it is user friendly it is versatile it encompasses all latest features and requirements of a modern alarm system and above all itis 100 a South African product We trust it will serve you well and afford you complete peace of mind whether at home or away DATE OF INSTALLATION INSTALLED BY CONTACT NUMBER X00329 SUPERTRACER_A5 UM 2 CDR
9. l Note It is strongly recommended that this be done in consultation with your installer If you have entered the programming mode 4 on Page 1 a yellow light will be ON for zone No 1 The two remote buttons have now assumed different roles where BUTTON B will toggle the corresponding red light and BUTTON A will step to the next zone In this way it is possible to change the patterns to suit new requirements An error may be easily rectified using BUTTONA to toggle back or BUTTON B to step right around To leave the programming mode PRESS BOTH BUTTONS TOGETHER BUTTONA amp BUTTON B Should you loose your remote call your installer to replace the remote and change your code AUTO ARMING if enabled When the auto arming feature is enabled programmable for 2 hours or 15 minutes by installer the system will arm itself if no movement or any other activations have been detected within the selected time period This function is useful when you forget to arm your alarm system The system will arm itself 15 min 2 hours after you have left the house or went to bed You can turn the auto arming on and off as you please Note Entry Exit will only function correctly if Zone 1 is the last zone triggered when you leave your premises Level A will be the at home sleep arming pattern and Level D the away arming pattern X00329 5 SUPERTRACER_A5 UM _2 CDR MULTI USER Operation ZONE SHARING One important fe
10. md 2345697 8 PER WARN OPERATION USER CODE ZONES ARM ZONE 1 BYUSER1 1 1 1 1 1 A ARM ZONE 1 BYUSER2 2 2 2 2 amp 2 A ARMZONE BY USER3 3 3 3 3 A 7 A MULTIPLE ENTRIES AND dd ET BISA UPDATING IS ALLOWED ARM PRESET PATTERN A 2 7 2 2 A ARM PRESET PATTERN B ARM PRESET PATTERN C ARM PRESET PATTERN D Set Warning by Users 1 2 3 amp 4 DER WARN ser ro warns zone 1 gt 2 2 2 2 FH 1 SET TO WARNING PRESET A gt 2 2 2 2 A ULTIPLE ENTRIES AND gt gt gt fo ANAAA NAOH Disarming and Resetting by Users 1 2 3 amp 4 DISARM ALL ZONES gt J 7 A ALL OFF If you are User 1 you can change the Codes of users 2 3 amp 4 CHANGE CODES OF USER 1 TO 10 1 1 4 4 H THE NEW CODE WILL BE PLAYED BACK ON THE DISPLAY y a HOLD PRESS TO ACCEPT THE NEW CODE TILL BEEP ANY OTHER KEY WILL ENTER A NEW CODE A NEW CODE 4 DIGITS USER NO 1 2 3 4 5 6 7 8 9 or A a If you are User 1 you can change the Follow me tel Number TOPROGRAM THE FOLLOWME TELNO gt 1 DOO AR a o0 3003 00 s TILL BEEP Ss il TO DISPLAY THE FOLLOWME TELMO gt 1 D D 4 paee H Be YS x If you are Us
11. s shown on the display HALE UVISSE KR aE TANT To IS X00329 _A SUPER TRACER USER A5 2 CDR THE REMOTE CONTROL f R The remote controls are supplied with either 1 2 standard or 3 buttons e 68 BUTTON A is used for Emergency Panic BUTTON B is used to arm disarm and reset the system BUTTON A amp B pressed together will send a test signal to the control room only with radio or tele communicator BUTTON B amp C pressed together will activate the lights IF IMPLEMENTED REMOTE PANIC BUTTON A button A will ALWAYS trigger the emergency operation and send a Panic signal to the control room ARM DISARM BUTTON B To arm the system see table on back page Press BUTTON B You now have four options not with SNIPER models 1 Let the system automatically step through the three levels A B C and automatically arm level D 2 While stepping through the preset levels press BUTTON A to select that level in ARM MODE 3 While stepping through the preset levels press BUTTON A to select that level in WARNING MODE 4 While stepping through the levels press both buttons at the same time to access the CUSTOMER programming mode see below which allows you to change the zone configuration in that pattern To disarm the system From armed warning status press BUTTON B until a two beeps are heard through the buzzer siren or the remote display l 19 00 NOTE A
12. single beep will indicate that the system has been armed When arming 6 short beeps indicate that one or more of the zones are in the open condition After the warning the system will Arm regardless but will not activate if the zone stays open Two beeps will indicate that the system has been disarmed ENTERING THE WARNING MODE Note that following mode WILL NOT trigger the siren or send a signal to the Control Room The buzzer will warn you whenever a zone is being violated Select the designated level to be in the warning mode Refer to the above table 1 Press BUTTON B once The system automatically steps through levels A to D 2 Stop the display at the level required by pressing BUTTON B once 3 The system is now SET TO WARNING MODE at this selected level GENERAL NOTES Resetting of the system may be done at any time using BUTTON B Indications on the remote display units are retained until the system is armed again This will allow you to ascertain the cause of the alarm even after resetting SECURITY LIGHTS OPERATION When using a 3 button remote control By pressing buttons B and C on a 3 channel remote control will activate the security lights relay This will remain on for about 4 minutes or until buttons B and C are pressed togther again If the lights are turned on by a sensor system dip switch setting they will remain on for about 4 minutes from the last activation CUSTOMER PROGRAMMING MODE using the remote contro
13. stem is running correctly If this indicator does not flash regularly please contact your installer X00329 1 SUPERTRACER A5 UM 2 CDR THE KEYPAD Each keypad can store in memory up to ten 4 digits USER codes Each code performs different tasks USER 1 CODE factory default 1111 The user 1 code allows the following operations Select any of the 4 preset patterns Select any of the individual zones Reset the system alarm Display the logged record of the last 255 alarm activations Change his her own password and those of users 2 to 10 Programming the telephone number for follow me operation USER 2 3 amp 4 CODES User codes 2 3 4 allow the following operations Select one of the 4 preset patterns Select any of the individual zones Reset the system alarm Change his her own password CODE USER 5 User 5 code is only used in MULTIUSER MODE and replaces User 1 and has then the same rights as users 2 3 and 4 USER 6 7 8 9 10 CODES User codes 6 7 8 9 and 10 allow the same functions as users 2 to 5 but can not change their own passwords which has to be allocated by user 1 or the installer ARMING YOUR SYSTEM preset levels user code the level required A e g 1111 a A Arms preset level a Individual zones user code the zones required A e g 1111 1 2 3 5 A Arms zones 12385 quick arming Press and Hold button A B C or D to Quick Arm the