Home
Wireless Lighting Control ZDS-110NA Dimming Switch Module
Contents
1. Wireless Lighting Control ZDS 110NA Dimming Switch Module USER MANUAL Z Wave Certified Wireless Lighting Control Introduction Thank you for choosing ZDS 110NA Z Wave control product Our Z Wave enabled product allows user to remotely control lighting home appliance and make home control easy at low installation maintenance cost You may begin with a few Z Wave enabled devices or build up a complete home automation system with our products The ZDS 110NA Dimming Switch Module is a Z Wave enabled device and fully compatible with any Z Wave enabled network It allows remote Dimming or On Off control of specified lamps Each module is designed to act as a repeater which will re transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacle and radio dead spots Glossary Devices lights and nodes are all terms to Light describe an individual Z Wave device sleds These are all interchangeable when setting up your Z Wave network Inclusion Add a Z Wave device to the network Exclusion Delete a Z Wave device from the network Device A collection of Z Wave devices configured to turn to a specific level setting mode or perform an operation Scenes are usually activated by a controller timed event or specific conditions Associations are used to set up one node to automatically contact another node when the first is triggered F
2. anwhile relies on the number of Z Wave enabled devices installed in the control network R R R D WARRANTY ONE YEAR LIMITED WARRANTY Remotec warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the original date of purchase from the distributor or dealer REMOTEC shall not be liable for Damages caused by defective devices for indirect incidental special consequential or punitive damages including inter alia loss of profits savings data loss of benefits claims by third parties and any property damage or personal injuries arising from or related to the use of the device Service trips to provide instruction on product use Shipping costs for replacement products This warranty is limited to the repair or replacement of this product only if the purchase date cannot be substantiated the warranty period will begin on the date of manufacture as indicated on this product All warranty claims must be made to Remotec appointed distributors or dealers during the applicable warranty period This warranty gives you specific legal right and you may also have other rights which vary in each country Please contact Customer Service at Remotec Technology Limited E mail rtlsales remotec com hk http www remotec com hk F820 8011 0000 68x128mm
3. enced radio TV technician for help IC information IC 9548A D9190A01 This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device This device complies with RSS 310 of Industry Canada Operation is subject to the condition that this device does not cause harmful interference There is no user serviceable parts in the Dimming Switch Module To avoid the risk of electric shock the input prong comes with a round grounding plug The switch module can only be plugged in to the power inlet with the grounding plug Please contact a qualified electrician to replace the power inlet if it has no grounding inlet Do not change the plug of Dimming switch module in any way SK OF FIRE SK OF ELECTRICAL SHOCK SK OF BURNS D NOT QUALIFY FOR INSTRUMENT OF MEDICAL AND LIFE SUPPORT EQUIPMENT Z Wave Dimming Switch Module never got qualified certificate to supply power for medical instrument or any life support equipment This Dimming Switch Module is complied with the Z Wave standard of open site line of sight transmission distances of up to 25m Actual RF performance of Dimming Switch Module in a home was affected by the number of barrier construction between the remote controller and the destination unit in me
4. frequency 908 42MHz ZDS 110NA Max range up to 25m line of sight between the Wireless Controller and the closest Z Wave receiver module Double outlets Z Wave controllable Always On pass through Selectable switch DIMMER Dimming ON OFF or SWITCH ON OFF mode Max output power of DIMMER Z Wave controlled Max Incandescent load 330W 2 75A SWITCH a Max Incandescent Load 330W 2 75A b Max Resistive Load 500W 4 16A Max power of Always On Resistive load 1200W pass through outlet Max power in total for both Resistive load 1400W Z Wave Outlet and Always DIMMER on Pass through outlet Can only be connected to incandescent lamp Resistive load SWITCH Can be connected to incandescent lamp Resistive load Connect ability Detected internal temperature and cut off output once OTP triggered Remark Under over loading or temperature situation it will fail to start up Meet FCC15 Class C and RSS 210 issue 8 Safety Meet standard UL244A edition third revision 2010 3 4 and CSA C22 2 No 14 11 with revision date 2010 2 1 and UL1310 fifth date 2005 05 03 Storage 10 60 C Specifications subject to change without notice due to continuing product improvement 6 Over Temperature protection Certifications UL Listed This power unit is intended to be correctly orientated in a vertical or floor mount position FCC Information FCC ID ZGID9190A01 This device complies with Part 15
5. lusion exclusion setup procedure When prompted by your primary controller tap the button The primary controller should indicate that the action was successful If the controller indicates the action was unsuccessful please repeat the procedure Once the Dimming Switch Module is part of the network the same basic procedure is used to add the Dimming Switch Module to groups or scenes Refer to the primary controller s instructions for details All On All Off functions Depending upon your primary controller the Dimming Switch Module can be set to respond to ALL ON and ALL OFF commands up to four different ways Some controllers may not be able to change the response from its default setting Please refer to your controller s instructions for information on whether or not it supports the configuration function and if so how to change this settings The four possible responses are It will respond to ALL ON and the ALL OFF commands default It will not respond to ALL ON and ALLOFF commands It will respond to the ALL OFF command but will not respond to the ALL ON command It will respond to the ALL ON command but will not respond to the ALL OFF command Restoring Factory Defaults All Configuration Parameters can be restored to their factory default settings by using your primary controller to reset the device delete from the network TECHNICAL SPECIFICATIONS Rating input 120Vac input reqendy RF
6. of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experi
7. or example you can set up a door sensor primary node to turn on the light secondary node when the door has been opened Association Key Features Selective slide switch for DIMMER SWITCH mode High output power in SWITCH mode High output power in DIMMER mode One Z wave controlled AC outlet for standard incandescent lighting One Always ON pass through AC outlet Remote ON OFF and Brightness control via the Z Wave controller Manual ON OFF and Brightness control with the front panel push button Fine appearance designed Space efficient design Does not block the lower outlet when plugged into the upper outlet of a duplex wall receptacle This assumes that the duplex receptacle is mounted with the ground pin down Plugs and cords for connected devices route to the side allowing close placement of furniture Grounded 3 wire power connection for safety Over temperature protection Configurations A ON OFF DIMMER PROG Push button B Always on outlet C Z Wave controlled outlet D AC plug E Selective switch On Off or Dimming Model A Warning The incandescent light plugged into the Z Wave controlled outlet on this module must not exceed 330 watts DO NOT connect fluorescent light Plugging a non resistive load such as fluorescent light or a device with a motor into the Z Wave controlled outlet may result in damage to the ZDS 110NA Dimming Switch Module and will void the wa
8. rranty Basic Operation The connected light can be turned ON in two ways 1 Manual control with the push button on the ZDS 110NA 2 Z Wave remote controller Push button V I 000000000 Z Wave remote controller Manual ON OFF DIM function 1 Switch to DIMMER mode 2 Plug the lamp into the Dimming Switch Module outlet which is labelled with Z Wave Ensure that the loading does not exceed 330 Watts Lower than 330 Watts Incandescent or Resistive Load 3 3 Plug the Dimming Switch Module into a wall AC outlet 4 Turn the light On Off by pressing the button This is a toggle switch Press the button to turn the light On if it is in Off stage and vice versa 5 Adjust the brightness level by pressing and holding the button Release the button when the desired level is attained This is also a toggle function Press and hold the button to dim up the light and press and hold the button again to dim down the light 6 In the SWITCH mode turn the light On Off by pressing the button This is a toggle switch Press the button to turn the light On if it is in Off stage and vice versa Lower than 330 Watts Incandescent or 500 Watts Resistive Load 4 68x128mm Z Wave Remote Control Include or exclude the Dimming Switch Module from the existing Z Wave home control network with your primary controller Refer to your primary controller instructions to process the inc