Home
User Manual - ADFWeb.com
Contents
1. User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG_ Revision 1 000 Page 1 of 23 Industrial Electronic Devices User Manual Revision 1 000 English BACnet IP Slave BACnet MSTP Master Converter Router Order Code HD67686 A1 HD6 686 B2 le ji fet iw sal C 3 d C k For Website information www adfweb com Product HD67686 HD67686 A1 HD67686 B2 For Price information www adfweb com Price HD67686 A1 www adfweb com Price HD67686 B2 Benefits and Main Features Very easy to configure Triple Electrical isolation For other BACnet products see also the following link Converter BACnet Master to Temperature range 40 C 85 C 40 F 185 F www adfweb com Product HD67712 Modbus Slave www adfweb com Product HD67714 Modbus TCP Slave www adfweb com Product HD67716 PROFIBUS Slave www adfweb com Product HD67717 CAN www adfweb com Product HD67718 CANopen www adfweb com Product HD67719 PROFINET www adfweb com Product HD67721 DeviceNet Slave www adfweb com Product HD67723 NMEA 2000 www adfweb com Product HD67725 31939 Do you have your customer protocol Then go to www adfweb com Product HD67003 Do you need to choose a device Do you want help www adfweb com Cmd helpme User Manual ADFweb com S r l iy User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 2 of 23 Industria
2. Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT For fast and easy technical support for your ADFweb com SRL products consult our internet support at www adfweb com Otherwise contact us at the address support adfweb com RETURN POLICY If while using your product you have any problem and you wish to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not be accepted If the product is within the warranty of twelve months it will be repaired or exchanged and returned within three weeks If the product is no longer under warranty you will receive a repair estimate ADFweb com S r l Via Strada Nuova 17 IT 31010 Mareno di Piave TREVISO Italy Phone 39 0438 30 91 31 Fax 39 0438 49 20 99 www adfweb com ADFweb com S r l
3. ADFweb com S r l shall not be liable for consequences of improper use OTHER REGULATIONS AND STANDARDS WEEE INFORMATION Disposal of old electrical and electronic equipment as in the European Union and other European countries with separate ps collection systems m This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it Should be taken to an applicable collection point for the recycling of electrical and electronic equipment If the product is disposed correctly you will help prevent potential negative environmental factors and impact of human health which could otherwise be caused by inappropriate disposal The recycling of materials will help to conserve natural resources For more information about recycling this product please contact your local city office your household waste disposal service or the shop where you purchased the product RESTRICTION OF HAZARDOUS SUBSTANCES DIRECTIVE 4 The device respects the 2002 95 EC Directive on the restriction of the use of certain hazardous substances in electrical OHS and electronic equipment commonly referred to as Restriction of Hazardous Substances Directive or ROHS 2002 95 EC CE MARKING The product conforms with the essential requirements of the applicable EC directives ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 23 of 23
4. All trademarks mentioned in this document belong to their respective owners iy User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 3 of 23 Industrial Electronic Devices SECURITY ALERT GENERAL INFORMATION To ensure safe operation the device must be operated according to the instructions in the manual When using the device legal and safety regulation are required for each individual application The same applies also when using accessories INTENDED USE Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator i e independent limit switches mechanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of this equipment and who have appropriate qualifications for their job RESIDUAL RISKS The device is state of the art and is safe The instruments can represent a potential hazard if they are inappropriately installed and operated by untrained personnel These instructions refer to residual risks with the following symbol This symbol indicates that non observance of the safety instructions is a danger for people that could lead to serious injury or A death and or the possibility of damage CE CONFORMITY The declara
5. ADFweb com S r l iy User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 19 of 23 Industrial Electronic Devices If you know the actual IP address of the device you have to use this procedure Turn on the Device with the Ethernet cable inserted Insert the actual IP of the Converter Press the Ping button must appear Device Found Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK the device automatically goes at Normal Mode At this point the configuration firmware on the device is correctly update Note g Mie When you install a new version of the software if it is the first time it is better you do the update of the Firmware in the HD67686 device l Z Note ve AN When you receive the device for the first time you also have to update the Firmware in the HD67686 device Warning A If Fig 6 appears when you try to do the Update try these points before seeking assistance BB 5wo7686 Ethernet Update Try to repeat the operations for the update Ver 1 001 INIT PROTECTION Try with another PC Try to restart the PC If you are using the program inside a Virtual Machine try to use it in the main PROJECT PROTECTION Operating System If you are using Windows Seven or Vista or 8 make sure tha
6. Ethernet Ethernet Power Supply Two directional information between BACnet IP bus and BACnet MSTP bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F 4 4 CONFIGURATION You need Compositor SW67686 software on your PC in order to perform the following Define the parameters of BACnet IP line Define the parameters of BACnet MSTP line Update the device ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 8 of 23 Industrial Electronic Devices POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below Consumption at 24V DC Device Consumption W VA Connector1 Power Supply port Caution Do not reverse the polarity power OV Ground i V Positive wire V AC min 8V max 24V V DC min 12V max 35V aiii _ One e Power Supply port OV Ground LE PRONE Wee HD67686 B2 HD67686 Al VAC min 8V max 24V V DC min 12V max 35V ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 9 of 23 Industrial Electronic Devices FUNCTION MODES The device has got two function modes depending on the position of the Dip2 of Dip
7. Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the operations to follow for the updating see UPDATE DEVICE section According to the functioning mode the LEDs will have specific functions see LEDS section Dip Switch A Boot Dip1 Must be at ON ae _ Z M Dip2 Functioning Mode i 5 I l Normal at Dip Switch A Dip1 Must be at ON Dip2 Functioning Mode Normal i Boot A Warning Dip1 of Dip Switch A must be at ON position to work even if the Ethernet cable is not inserted ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 10 of 23 Industrial Electronic Devices LEDS The device has got four LEDs five for the HD67686 B2 that are used to give information about the functioning status The various meanings of the LEDs are described in the table below LED Normal Mode Boot Mode l l ON Device powered 1 Device State green Blinks slowly 1Hz OFF Device net powered ON Ethernet cable connected Blinks quickly Boot state 2 Ethernet Link green OFF Ethernet cable disconnected Blinks very slowly 0 5Hz update in progress Blinks quickly Boot stat
8. stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x 24AWG stranded twisted pairs conductor foil shield braid shield Tasker p n C521 1x 24AWG twisted pair conductor foil shield braid shield Tasker p n C522 2x 24AWG twisted pairs conductor foil shield braid shield ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 12 of 23 Industrial Electronic Devices ETHERNET The BACnet IP connection and the updating of the converters must be made using Connector5 of HD67686 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connect the device to a PC PLC other is recommended the use of a cross cable Connectors Ethernet Port RJ45 Plug ADFweb com S r l Industrial Electronic Devices USE OF COMPOSITOR SW67686 User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 13 of 23 To configure the Converter use the available software that runs with Windows called SW67686 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the sof
9. 000 Page 18 of 23 Industrial Electronic Devices UPDATE DEVICE Update Firmware from Ethemer UDP By pressing the Update Device button it is possible to load the created Configuration into the device and also the Firmware if necessary SW6 686 date Firmware f i If you don t know the actual IP address of the device you have to use this procedure AAA Pere een Ete cee gt Turn off the Device Insert eee panies of ESH Put Dip2 of Dip Switch A in ON position aes E eE eeenet Turn on the device Check the Connection the device Connect the Ethernet cable E Fennell Insert the IP 192 168 2 205 Press the Ping button Device Found must appear Press the Next button Select which operations you want to do Update Firmware from Etherner UDP Press the Execute update firmware button to start the upload FESSES When all the operations are OK turn off the Device SW6 1686 Put Dip2 of Dip Switch A in OFF position neste PAPETA tes tant KATRE CSOT Turn on the device Update Device Options Firmware At this point the configuration firmware on the device is correctly updated W Read Firmware when finish Configuration Read Configuration when finish aa uf Execute update firmware i B SW67686 Ethernet Wer 1 001 INIT Waiting FIRMWARE Waiting PROJECT Waiting Figure 4 Update device windows
10. 2 ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 21 of 23 Industrial Electronic Devices ORDERING INFORMATIONS The ordering part number is formed by a valid combination of the following HD67686 xx L Connectors Type 1 Removable 5mm Screw Terminal 2 Fixed 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting B 4M 35mm DIN Rail mounting Device Family HD67686 BACnet IP Slave BACnet MSTP Master Router Order Code HD67686 A1 BACnet IP Slave BACnet MSTP Master Router Order Code HD67686 B2 BACnet IP Slave BACnet MSTP Master Router ACCESSORIES Order Code AC34001 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V AC Order Code AC34002 35mm Rail DIN Power Supply 110V AC 50 60Hz 12 V AC ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 22 of 23 Industrial Electronic Devices DISCLAIMER All technical content within this document can be modified without notice The content of the document is a under continual renewal For losses due to fire earthquake third party access or other accidents or intentional or accidental abuse misuse or use under abnormal conditions repairs are charged to the user ADFweb com S r l will not be liable for accidental loss of use or inability to use this product such as loss of business income
11. e ae Be a Onl Blinks when BACnet MSTP data RS485 are received h green Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 4 BACnet IP comm yello Blinks when BACnet IP data Ethernet are received yee Reker wails oe Blinks very slowly 0 5Hz update in progress Blinks quickly Boot state 5 Not Used OFF Blinks very slowly 0 5Hz update in progress Ledi Ledi ee Green Green Device state Device state Led3 7 Yellow BACnet MSTP Communication Ethernet Link H AY Yellow a BACnet IP a Communication Led5 SS 1 1 IAS Yellow Not used ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 11 of 23 Industrial Electronic Devices RS485 To terminate the RS485 line with a 220Q resistor it is necessary to put ON dip 1 like in figure Connectors RS485 Isolated port Dip Switch B Dipl RS485 Termination Resistor S Shield to Isolated Ground B Negative wire A Positive wire SBA Dip2 Not used Dip Switch B Connectors Dip1 RS485 Termination Resistor IRS485 Isolated port 220 Ohm l _ S Shield to Isolated Ground B Negative wire IA Positive wire The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG
12. ection scheme for HD67686 A1 ADFweb com S r l Led2 Green Ethernet link e Ledi Green Device state A Connector i1 Power Supply port OV Ground W Positive wire V AC min 8V max 24V V DC min 12V max 35V User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 6 of 23 Industrial Electronic Devices Dip Switch A Dipi Must be at ON Dip2 Functioning Mode Dip Switch B Connector3 Dipl RS485 Termination Resistor RS485 Isolated port S Shield to Isolated Ground B Negative wire A Positive wire Normal ie Boot Dip2 Not used _ PP y EAT DOSED D ay Sena Nr 00555 B a Ae Qn N OC AL A ears h EOE Pal wer ADFweb c Dip Switch 4 Dip Switeh BE R5455 GCOOOSSOOCOO000 V Positive wire Led2 Green DC min 12V max 35V Figure 1b Connection scheme for HD67686 B2 ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 7 of 23 Industrial Electronic Devices CHARACTERISTICS The HD67686 Al1 and the HD67686 B2 are BACnet IP BACnet MSTP Converters It allows for the following characteristics Router function Completely transparent converter from BACnet IP to BACnet MSTP and vice versa Triple isolation between RS485 Power Supply RS485
13. figuration List of Avaliable Configurations ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 15 of 23 Industrial Electronic Devices SOFTWARE OPTIONS By pressing the Settings gt button there is the possibility to change the EBS Software Options language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software Software Options Language Connection Options Selected Language e English Page i 1 Language Connection Options Enable Internet Connection Check Software Update at Start of Program Check Available Update In the section Connection Options it is possible to check if there are some updatings of the software compositor in ADFweb com website Checking the option Check Software Update at Start of Program the SW67686 check automatically if there are updatings when it is launched ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 16 of 23 Industrial Electronic Devices SET COMMUNICATION EB set Communication all This section define the fundamental communication parameters of two buses BACnet IP and BACnet SW6 686 MSTP Set Communication Setting By Pressing the Set Communication button from the main wi
14. l Electronic Devices INDEX UPDATED DOCUMENTATION INDEX UPDATED DOCUMENTATION REVISION LIST WARNING TRADEMARKS SECURITY ALERT EXAMPLE OF CONNECTION CONNECTION SCHEME CHARACTERISTICS CONFIGURATION POWER SUPPLY FUNCTION MODES LEDS RS485 ETHERNET USE OF COMPOSITOR SW67686 NEW CONFIGURATION OPEN CONFIGURATION SOFTWARE OPTIONS SET COMMUNICATION UPDATE DEVICE MECHANICAL DIMENSIONS ORDERING INFORMATIONS ACCESSORIES DISCLAIMER OTHER REGULATIONS AND STANDARDS WARRANTIES AND TECHNICAL SUPPORT RETURN POLICY ADFweb com S r l 9 NRPRPRP RP RPP Pe fal OOMODUKRWNHPROVANNUBWNNNNNG 21 Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand corner of each page of this document With this Document Code go to web page www adfweb com download and search for the corresponding code on the page Click on the proper Document Code and download the updates REVISION LIST Revision Date Author Chapter Description 1 000 20 05 2013 Ff All First Release WARNING ADFweb com reserves the right to change information in this manual about our product without warning ADFweb com is not responsible for any error this manual may contain TRADEMARKS
15. ndow for SW67686 Fig 2 the Reve He window Set Communication appears Fig 3 sets 192 168 The means of the fields for BACnet IP are T Ae Inthe fields IP ADDRESS insert the IP address that you want to give to the Converter I 255 255 Inthe fields SUBNET Mask insert the SubNet Mask TERENA In the fields GATEWAY insert the default gateway that you want to use This feature can s oo be enabled or disabled pressing the Check Box field This feature is used for going out of the net Port 47808 In the field Port the port number used for BACnet communication is defined The default r E A E Name port used for BACnet communication is 47808 but is possible to insert any value except 10000 and 10001 devicenamel Inthe field BACnet Device Name is possible to assign a name to the BACnet node Deca TWENDE Inthe field Device Istance is possible to assign a number to the BACnet node BACnet IP Network In the field BACnet IP Network is possible to define the number of the BACnet IP network BACnet MS TP Baudrate 9600 The means of the fields for the BACnet MS TP section are Parity NONE In the field Baudrate it is possible to select the baudrate of the BACnet line 1200 2400 DRC ny SE 4800 9600 19200 38400 57600 115200 Inthe field Parity it is possible to select the parity of the line None Odd Even hens ane Inthe field MAC Address is po
16. ssible to define the MAC of BACnet node from O to 127 Max Info Frames The field Max Master specifies the highest allowable address for master nodes The value Shall be less than or equal to 127 The field Max Info Frames specifies the maximum number of information frames the node may send before it must pass the token In the field MS TP Network is possible to define the number of the BACnet MS TP network MS TP Network Figure 3 Set Communication window ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 17 of 23 Industrial Electronic Devices a Example The HD67686 is completely transparent and it has the functionalities of a BACnet Router When a BACnet IP Master sends a request to the converter it converters it in BACnet MS TP As soon as the BACnet MS TP slave send the response the converter converts in BACnet IP The response from BACnet MS TP is received by the HD67686 STEP 3 The converter sends the BACnet IP request on BACnet MS TP Network STEP 2 BACnet MS TP Network The response from BACnet MS TP is sent by the HD67686 to the BACnet IP Master STEP 4 i BACnet IP Master sends the request to the HD67686 STEP 1 BACnet IP Network ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1
17. t you have the administrator privileges FIRMWARE PROTECTION Pay attention to the Firewall lock Figure 5 Protection window Check the LAN settings A In the case of HD67686 you have to use the software SW67686 www adfweb com download filefold SW67686 zip ADFweb com S r l iy User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 20 of 23 Industrial Electronic Devices MECHANICAL DIMENSIONS uk an O LEDA BACnet MS TP Era S V OV C LEDI BACnet 1P comm O RS485 port Power Supply Dip Switch B amp 24V AC or 12_ 35V DC Power Supply bar snaeepor3e 0t fr GOS55 o ETHERNET Ov W Serial es cq AIN AE u 4 ewe simie BACnet IP slave BACnet MS TP master Converter A1 Brom or CI LED Ethernet Link Seti HD67686 a g c 5 TE DC www ADFweb com A E Cc f _ exnemet ae sk Ce Kr Dip Switch A c s B185 MAC 10 64 E2 07 33 BF oO On eer ADEN EE COM O LEDI Devke state f Date Code 24 14 Serial Nr C2318 oHS ew eg im BaCren TP 7 BACnet STP Converter HD67686 B2 Eo Dip Switeh A Dip 5wibch B AS54865 pert A SISDIDIDI 1 1 IOIDISISIT T1 mm 60 mm peee 3 mm 2 79 inch 2 36 inch 4 72 inch 0 9 inch Housing PVC Housing PVC Weight 200g Approx Weight 200g Approx Figure 6a Mechanical dimensions scheme for HD67686 A1 Figure 6b Mechanical dimensions scheme for HD67686 B
18. tion is made by our company You can send an email to support adfweb com or give us a call if you need it ADFweb com S r l User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG Revision 1 000 Page 4 of 23 Industrial Electronic Devices EXAMPLES OF CONNECTION i BACnet IP network s BACnet MSTP network Ethernet RS485 cable 6 EA Bis 3 BACnet IP Master _ BACnet MSTP Slaves HD67686 Al1 BACnet IP network BACnet MSTP network RS485 cable OOO Se e OeQOOODO HD67686 B2 BACnet IP Master BACnet MSTP Slaves ADFweb com S r l User Manual Document code MN67686_ENG BACnet IP Slave BACnet MSTP Master Router Revision 1 000 Page 5 of 23 Industrial Electronic Devices CONNECTION SCHEME Dip Switch A Dipi Must be at ON L S i Dip2 Functioning Mode Boot Normal ae NA S V OV O LEDI BACnet IF comm amp R5485 port Power Supply Dip Switch B 8 24 AC or 12 354 DC ge BACnet IP slave BACnet MS TP master Converter OLED Ethemet Link fal ra HD67686 A1 a Fo ae a F rer ADF ereh oon H Ethernet J n a oe ee Dip Switch A C 77 Cs B185 MAC 10 64 E2 07 33 BF Date Code 24 14 Serial Nr C2318 oHS O LEDI Device state V OV ABS Dip Switch B Connectors S Shield to Isolated Ground B Negative wire A Positive wire Figure 1a Conn
19. tware present on our web site The software works with MSWindows XP Vista Seven 8 32 64bit When launching the SW67686 the window below appears Fig 2 Note A It is necessary to have installed Net Framework 4 SW67686 T AX BACnet IP slave BACnet MS TP master Converter E Begin Step 1 Step 2 Step 3 ADFweb com S r l Opened Configuration of the Converter Examplel New Configuration Open Configuration gt Set Communication Le Update Device www ADFweb com Figure 2 Main window for SW67686 User Manual BACnet IP Slave BACnet MSTP Master Router Document code MN67686_ENG_ Revision 1 000 Page 14 of 23 Industrial Electronic Devices NEW CONFIGURATION OPEN CONFIGURATION The New Configuration button creates the folder which contains the entire device s configuration SW676 Create New Configuration Name of the new Configuration Example A device s configuration can also be imported or exported as Open Conus To clone the configurations of a programmable BACnet IP BACnet MSTP SW6 686 Converter in order to configure another device in the same manner it is necessary open an Existing Configuration to maintain the folder and all its contents To clone a project in order to obtain a different version of the project it is sufficient to duplicate the project folder with another name and open the new folder with the button Open Con