LC Plus Series safety and installation guide

image

Contents

1. 6 See Figure 5 Do not use the ventilation holes arrowed in the top rail to support the weight of panels when lifting or installing The only permitted method of supporting the weight of panels is by means of two conical couplers fastened into the coupler sockets in the top rail and secured with spigots as shown in Figure 7 T on page 11 T Wo nN Figure 5 Holes for ventilation only 10 LC Plus user manual 7 As soon as a panel is fastened in place install two safety cables to secure it Safety attachments must be able to bear at least 10 times the weight of all the panels they secure See Figure 6 Loop safety cables in a figure of eight around vertical side columns and the supporting structure or the panel above so that if a rigging clamp or conical connector fails the weight of the panels will be held by the vertical columns and the blocks the columns are anchored in and not by the panel bases
2. External P3 100 System Controller one per system Processor Capacity 500 000 pixels 400 LC Plus 2140 panels with P3 100 O tput resolutio Los err e RES A See be cR Any within 500 K pixel limit Total system latency worst Casel Less than 3 frames DVI VIGGO INPUT 3 teres pate Eois eked Gk oh EE Up to 1280 x 1024 50 60 75 Hz Analog video inpuUt Composite component and S video PAL NTSC and SECAM E Lasst eL Sc ILLI A Yes integrated in P3 100 processor Image TOTAUON EM ERE ML EE Yes integrated in P3 100 processor Sicalitig oat ht re ates res EE Yes integrated in P3 100 processor De Interlacigscd sed oras ux ara Yes integrated in P3 100 processor Gamma curve selection and adjustment n n nannan annann ana Yes integrated in P3 100 processor Real time panel content remapping Yes integrated in P3 100 processor P3 Signal Protocol Naty pE EE Gigabit Ethernet o O cedo o eA HR A Proprietary Martin P3 HOUDIBJgJbIG x22 30 5 3 3 e itd a Yes electrically isolated at all connections alodio eG eee tl eet e tes ees rU ER RT Cat 5e or better STP Cable length Up to 100 m 328 ft between any 2 devices extendable with Ethernet switch Max number of panels per chan 50 extendable with Ethernet switch Latency between first and last panel e None Photometric Data EIGNE S OUNCE 2 25 2 2 LT BB abra aseado 5 mm 0 2 in oval LED Brightness calibrated
3. eee 3000 Nit candela per square meter Pitch pixel center to center 0 0 0 0 0c eee eee eee eens 40 mm 1 6 in Fed dominant wavelength visir a A a aeaa i 621 nm Green dominant wavelength o o o ooooooor een 527 nm Blue dominant wavelength EE 470 nm Ce 0181911110 EE 16 bits per color Viewing anglesi niet cea Sot oes rs Be ete ears gt 100 horizontal gt 40 vertical at 50 intensity LC Plus 2140 Resolution one panel urraca 25 x 50 pixels POIS ae EE 1250 LEDSDEY PANE 277275 eet pro vista dd he SD rd Sse ah OE Se 3750 LC Plus 1140 Resolution one panel 0 ccc ee ee eee ee hh hn 25 x 25 pixels Pixels Der panelzc prr 5 cous tte at eee ao hee RR Oa A ae ia ee Sch 625 LEDS Del el EE 1875 LC Plus user manual Construction Fariel IatTiBS 5 74 EE EE Aluminum FE WEDS sets RE RET EE UV resistant acrylic LED TUDES EE 25 Transparency through LED tubes unmasked area ee eee gt 60 elle Matt black Prote cio Maldita As a los IP 65 NEMA A Installation Orientation Individually mounted panel any angle stack or suspended chain horizontal or vertical only Max suspended in one chain Max six LC Plus 2140 panels hung vertically per single chain Max stacked Max seven LC Plus 2140 panels standing vertically per single stack Panel THOLTOOKIDG DEER Prolyte CCS6 conical coupler system Connections Powet In OUl restos ps p Dard osea OPERE EVEN Quick
4. N D D Power input connector Used to supply power to the panel Accepts an Amphenol IP67 rated power input female cable connector E Power throughput output connector Used to relay power to another LC Plus panel Accepts an Amphenol IP67 rated power output male cable connector The voltage and frequency available at this connector are the same as those applied at the power input connector D Warning A maximum of FIVE LC Plus 2140 panels in total or TEN LC Plus 1140 panels in total may be connected to power in one chain that draws power through the first panel s power input connector All connectors that are not in use must be sealed at all times with the caps provided Figure 1 Connections LC Plus user manual Introduction This Installation and Safety Manual explains how to install configure and maintain Martin LC Plus video panels The Safety section contains important information about safety precautions The installation section contains details of how to physically install panels and cables connect panels to power and prepare for connection to a Martin P3 100 System Controller and video source For information about installing and using the P3 100 System Controller see the P3 100 user documentation supplied with the P3 100 All LC Plus Series and P3 100 user documentation is also available for download free of charge from the Product Support area at www martin com Thank you for
5. 1 Vacuum or gently blow away dust and loose particles from the heatsink fins on the base of the panel with low pressure compressed air 2 Wipe the outside of the LED tubes with a soft lint free cloth dampened with a solution of water and detergent or auto shampoo Apply gentle pressure only Installing new software It may be necessary to upload new software to the LC Plus if the product appears to have a software related fault or if you want to update to a newer software version Software updates are available from Martin and can be installed from the P3 100 System Controller over the P3 link See the P3 100 System Controller user manual for instructions for this procedure 22 LC Plus user manual Troubleshooting Problem Probable cause s Remedy Panel is completely dead One or more panels displays video incorrectly or does not display video at all All panels and or monitor screen display video incorrectly or do not display video at all Display cuts out intermittently One LED tube cuts out No power to panel Fuse blown Incorrect panel settings on P3 100 System Controller Fault on P3 link Panel defective Other device e g Ethernet switch on P3 link defective Incorrect video input or panel settings on P3 100 System Controller Unusable video signal or defective video source Fault on P3 link Device on P3 link defective Panel is too hot LED tube incorrectly installed an
6. Each LC Plus panel has two RJ 45 Ethernet sockets see A and B in Figure 1 on page 6 for connection to the P3 link All sockets are bi directional handling both P3 signal input and output Cable and connector types Use good quality CAT 5e or better STP shielded twisted pair Ethernet cable for the P3 link in an installation with LC Plus panels RJ 45 connectors should be shielded type with the shield around the connector terminals electrically connected to the cable shield The two Ethernet sockets on each panel are mounted in Amphenol IP67 rated reverse bayonet mount housings For outdoor use RJ 45 plugs installed in Amphenol RJF RB 6 housings as supplied with the panel must be used at all times Any unused sockets must be sealed with the cap attached to each socket For indoor use in dry locations non IP rated standard RJ 45 Ethernet connectors and patch cables may be used Suitable IP67 rated and non IP rated patch cables in various lengths and suitable connector housings are available from Martin see Accessories on page 26 Planning the P3 link 16 Figure 11 shows an example of P3 system layout Media source As a media source we recommend the use of a product from the Martin Maxedia series Maxedia products offer fast processors advanced features DVI output and an intuitive user interface Besides a Maxedia media server processor any video camera or video source with an S video composite video or component vide
7. Series products are packaged either in sets of 4 panels in a 4 unit flightcase or as single panels in a cardboard box The following items are included In the cardboard box e 4x conical couplers Prolyte CCS6 system P N 21021150 e 8 x threaded spigots for LC Plus conical coupler P N 08330127 8 mm hex key for threaded spigots P N 50520619 e 5m 16 4 ft power input cable with IP67 input connector for single phase power P N 11521030 e 5m 16 4 ft power input cable with IP67 input connector for 2 phase power P N 11521034 e 1 5 m 4 9 ft power throughput cable with IP67 connectors for single phase power P N 11521031 e 1 5 m 4 9 ft power throughput cable with P67 connectors for 2 phase power P N 11521033 Introduction 7 Important 2 5 m 8 2 ft Ethernet patch cable with IP67 RJ 45 connectors P N 11840146 e 1 5m 4 9 ft Ethernet patch cable with IP67 RJ 45 connectors P N 11840140 e LC Plus Installation and Safety Manual P N 35000218 In the 4 unit flightcase 16x conical couplers Prolyte CCS6 system P N 21021150 e 32 x threaded spigots for LC Plus conical couplers P N 08330127 8 mm hex key for threaded spigots P N 50520619 e 5 m 16 4 ft power input cable with IP67 input connector for single phase power P N 11521030 e 5 m 16 4 ft power input cable with IP67 input connector for 2 phase power P N 11521034 e 4x 1 5 m 4 9 ft power throughput cables with IP67 connectors for single phase po
8. US color coded for 2 phase power 4 x P N 11521033 Four 2 5 m 8 2 ft Ethernet patch cables with IP67 rated RJ 45 connectors 4 x P N 11840146 Four 1 5 m 4 9 ft Ethernet patch cables with IP67 rated RJ 45 connectors 4 x P N 11840140 Safety and Installation manual P N 35000218 Threaded spigots for LC Plus and standard LC panels are not interchangeable Accessories Amphenol C016 20 D 003 100 12 power input connector cable mount Amphenol C016 20 H 003 100 12 power output connector cable mount Prolyte CCS6 conical coupler c c P N 21021150 Threaded spigot for LC Plus conical coupler fits LC Plus not standard LC P N 08330127 Female conical coupler socket with hole for spigOt u P N 21021151 Half conical coupler floor mounting option with hole for spigot length 44mm P N 21021152 Half conical coupler floor mounting option with hole for spigot length 63 mm P N 21021153 Half conical coupler floor mounting option without hole for spigot length 44 mm P N 26820300 Four unit flightcase for 4 x LC Plus 2140 videopanelS eee eee P N 91510120 Martin P3 100 System Controller Installation and Safety Manual P N 35000226 Martin P3 100 System Controller User Documentation CD P N 35005008 All LC Plus and P3 system controller user documentation is also available for downl
9. or attach panels Do not use the ventilation holes in the top rail or the LED tubes as attachment points Warning Secure every panel with two safety cables that are approved for the weight they secure and installed as described in this manual Warning When stacking panels one on top of another or suspending panels one from another do not exceed the limits given in Figure 3 If an installation needs to be taller than the limits given in Figure 3 additional support points must be provided to bear the weight of the additional panels Warning When stacking panels secure them so that they cannot tip or fall The LC Plus can be installed in a standing position alone or stacked flown in a vertical curtain or suspended in any orientation from a truss or supporting structure Stacked Stacked Suspended Suspended upright on side upright on side BE T B m LC Plus 1140 Max 9 Max 8 Max 8 Max 8 JEN S LN Li Co Ge EJ a Max 7 Max 5 Max 6 Max 6 Figure 3 Safety limits for stacking and suspending attached panels Standing installation See Figure 3 One vertical stack with LC Plus 1140 panels resting on each other may contain a maximum of nine LC Plus 1140 panels stacked upright or eight LC Plus 1140 panels stacked on their sides Physical installation 9 One vertical stack with LC Plus 2140 panels resting on each other may contain a maximum of seven LC Plus 2140 panels stack
10. selecting the Martin LC Plus a product from the LC Series of modular LED based video display panels from Martin This product features 40 mm pixel pitch seamless image at approx 30 m 3000 Cd m2 3000 nits effective light output at 25 C 77 F e Rich RGB color e 25 x 50 pixels LC Plus 2140 or 25 x 25 pixels LC Plus 1140 per panel image resolution Color resolution of 16 bits per color e 100 x 40 viewing angle e Silent convection cooling P3 signal in out via daisy chainable Amphenol IP67 rated ruggedized bayonet mount RJ 45 connectors e Auto sensing 200 240 VAC nominal switch mode power supply e Amphenol IP67 rated ruggedized threaded locking power connectors e Prolyte CCS6 conical coupler system for fast installation For the latest firmware updates documentation and other information about this and all Martin Professional products please visit the Martin website at http www martin com Comments or suggestions regarding this document may be e mailed to service 9 martin dk or posted to Technical Documentation Service Department Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Denmark Warning Read Safety Information on page 3 before installing powering operating or servicing the LC Plus This is an ITE Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take appropriate measures Unpacking LC Plus
11. 10 EE 7 USING Tor thie TRS TIM EE 8 LG PIUS MAME AS EE 8 Physical Install rO EE 9 Standing Re AON EE 9 Flying from a truss bar or other strUCtUr eae 10 PAG DOW OM E 12 PoOWer eg 12 l OWBF CODO COL EE 13 P3 communication link 16 Fanning the Ge Wel soos cedros X OP xe ad E RACE Ed dee ae ee eS 16 Connecting Me EE 18 Configuration and testing EE 19 Control panel display and status indicators 19 ResettingandrebootingpanelS c cc 21 Service and maintenance c c 22 eru gt 6 cco EE 22 Installing new software 22 Reif leie lee e Le MEET 23 DCCC ANON Sc ment san toe dan oma eden EE ee Rate ee Rees 24 Connections overview e o Tere A Ethernet port 1 Used for bi directional P3 system communication Accepts an Amphenol IP67 rated Ethernet cable connector or a standard Ethernet connector for indoor use only Warning All connectors that are not in use must be sealed at all times with the caps provided B Ethernet port 2 Used for bi directional P3 system communication Accepts an Amphenol IP67 rated Ethernet cable connector or a standard Ethernet connector for indoor use only Warning All connectors that are not in use must be sealed at all times with the caps provided C Control panel and LED display See Using the control panel and control panel display on page 19 for details Se eo
12. LC Plus LED Video Display Panel Installation and Safety Manual m Dimensions All dimensions are in millimeters Lo HEN 123 A O oa 1000 E 126 152 2009 Martin Professional A S Information subject to change without notice Martin Professional A S and all affiliated companies disclaim liability for any injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The Martin logo the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional A S or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional A S or its affiliates or subsidiaries P N 35000218 Rev C Safety Information WARNING Read the safety precautions in this section before installing powering operating or servicing this product The following symbols are used to identify important safety information on the product and in this manual AAA AAA Warning Warning Warning Warning Warning Warning Safety hazard Refer to Hazardous Hotsurface Do Fire hazard Emission Risk of severe manual before voltage Risk of not touch hazardous to injury or death installing lethal or severe eyesight powering or electric shock servicing This product is for professional use only It is not for househ
13. Plus 1140 panels in total may be interconnected using power throughput connectors to form one chain that draws power via the first panel s power input cable Two types of power input and power throughput cable are supplied with each panel see Figure 8 e EU color coded cables fitted with connectors with a black shell You must use these input and throughput cables when using single phase AC mains power US color coded cables fitted with connectors with a blue shell You must use these input and throughput cables when using two phase AC mains power All cables are 16 A rated UL listed 16 AWG black blue EU type US type for single phase power for 2 phase power Figure 8 Power cable connectors Table 1 on page 15 gives details of the standard wiring color codes used in these two cable types as well as common pin identification symbols If you have any doubts about proper installation consult a qualified electrician Separate Amphenol connectors and replacement power cables with Amphenol connectors installed are available from your Martin supplier The supplied power cables can be replaced with cables from other sources but replacement cables must be 3 conductor with a Hypalon or neoprene rubber jacket approved for a current of 16 A and temperature of 90 C 194 F minimum Replacement cables must also be minimum 16 AWG and UL listed in North America or have conductor size minimum 1 5 mm in other regions To conn
14. ROTECTION FROM FIRE Provide a minimum clearance of 30 cm 11 8 in around the heatsink at the back of the panel base Do not stick filters masks or other materials directly onto LED tubes Do not modify the product in any way not described in this manual Install only genuine Martin parts in or on the product unless an alternative is described in this manual Do not operate the product if the ambient temperature Ta exceeds 40 C 104 F PROTECTION FROM INJURY Ensure that any structure used for support as well as all fastening and connecting hardware can hold at least 10 times the weight of all supported devices and equipment When lifting a panel suspend it using two approved conical couplers with eyebolts Use two approved conical couplers to suspend the panel from the supporting structure Do not suspend panels using any other method of attachment than those described in this manual When stacking panels on top of each other fasten panels securely to prevent them from tipping or falling and do not stack more than Nine LC Plus 1140 panels standing upright Eight LC Plus 1140 panels lying on their side Seven LC Plus 2140 panels standing upright or Five LC Plus 2140 panels lying on their side When suspending in a curtain with panels hanging from each other use two conical couplers to suspend each panel and do not suspend more than Eight LC Plus 1140 panels hanging upright Eight LC Plus 1140 panels hanging sidew
15. ays Six LC Plus 2140 panels hanging upright or Six LC Plus 2140 panels hanging sideways When mixing LC Plus 1140 and LC Plus 2140 products in a stack or curtain observe the maximum limit for LC Plus 2140 panels stated above Use a minimum of two approved secondary attachments such as safety cables to secure each product as described in this manual Safety cables must be approved by an official body such as TUV as a safety attachment for the weight of all the fixtures it secures Safety cables must comply with EN 60598 2 17 Section 17 6 6 and be capable of bearing a static suspended load ten times the weight of the fixture Check that all external covers and rigging hardware are securely fastened Block access below the work area and work from a stable platform whenever installing servicing or moving the product Do not look at lit LEDs from a distance of less than 40 cm 1 ft 4 in without suitable protective eyewear Do not view lit LEDs with optical instruments that may concentrate the light output The surface of the heatsink in the base of the panel can become hot over 80 C 176 F during normal operation Install panels in a restricted area only in order to ensure that accidental contact by members of the public is impossible LC Plus user manual Contents DIMENSIONS EE 2 SAE LOLA O 1 8 Tei EE 3 CONNECTIONS oVervVIeWrza 2002220800 30868 Ud eun ede ies Gao hens aba Pee eee 6 NEO OQUICUIONN P EET 7 815 6 2 014 3
16. d connected LED tube fuse has blown Table 6 Troubleshooting Troubleshooting Check power and connections Disconnect panel from power Contact Martin Professional for service Check settings display addresses panel Device Properties etc Inspect connections and cables Correct poor connections Repair or replace damaged cables Have faulty panel serviced by Martin service technician Replace with a device known to be operating correctly Have faulty device tested and serviced Check settings PAL SECAM NTSC selection overall panel intensity setting etc Check video source Inspect connections and cables Correct poor connections Repair or replace damaged cables Have faulty panel or device tested and serviced by Martin service technician or supplier Ensure free airflow around heatsink Clean heatsink Check that ambient temperature does not exceed max permitted level Contact Martin for service Check tube Contact Martin Professional for service 23 Specifications 24 Physical MO EE ER 1000 mm 89 4 in PSU toe orig Sects bacs wed cn Cacao os EE 152 mm 6 in Helght LO Plus 21400 cosida ii e E A 2000 mm 78 8 in Weight LG PIUS 214072 uie A de Ee pra BEER GE Beets 22 4 kg 47 0 Ibs Control User Interface Addressing and status ee eee Onboard control panel with LED display status LEDs SED testind WEE Local test patterns Video Processing Video signal processor
17. d to panels that are incorrectly packed or exposed to abnormal shocks is not covered by the product warranty When removing panels from the flightcase keep all protective material for use when repacking Transport and store flightcases standing in an upright position only Do not transport flightcases lying flat on their side LC Plus user manual PACKING INSTRUCTION cooling fins 1 7 7 fit only in Figure 2 Flightcase packing Physical installation Warning Read Safety Information on page 3 before installing the LC Plus Warning The safety and suitability of lifting equipment installation location anchoring method mounting hardware and electrical installation is the responsibility of the installer All local safety regulations and legal requirements must be observed when installing and connecting the LC Plus Warning Installation must be carried out by qualified professionals only Contact your Martin supplier for assistance if you have any questions about how to install this product safely Warning The surface of the heatsink in the base of the panel can become hot during normal operation Install so as to prevent accidental contact by members of the public Warning Use two conical couplers to fasten a panel to a supporting structure or to another panel When lifting a panel use two conical couplers as attachment points for lifting gear Do not use only one conical coupler or any other method to suspend lift
18. ect an Amphenol power cable connector to an LC Plus panel line up the keys in the cable connector with the slots in the corresponding chassis connector in the rear of the panel base D or E in Figure 1 on page 6 push the cable connector firmly into the chassis connector then twist the locking ring on the cable connector clockwise to screw the connectors together and form a waterproof and dustproof seal Any connectors that are not being used must be sealed with their caps at all times There is no power on off switch on LC Plus panels Apply and shut down power using an external switch at the power outlet or at the main switchboard Make sure that the external switch is near the panels and easily accessible so that power to the panels can easily be shut down if necessary Do not power panels on or off by inserting or removing live power connectors as this will cause arcing at the connector contacts that may damage devices and connectors AC power 13 14 Installing power cable connectors Installing Amphenol connectors m eco mate ETS Mounting Instruction straight cable connector Stripping Lengths Screw contacts with internal cable retention 18 ps without internal cable retention 25 pi Solder contacts with internal cable retention EM 4 without internal cable retention 22 4 Crimp contacts 0 14 0 50 mm 3105 clamping ring with mounted gasket o 0 50 1 5 mm 397 back shell with internal cable retention 14 tighteni
19. ed upright or five LC Plus 2140 panels stacked on their sides An unlimited number of stacks of panels may be installed alongside each other If you install panels in a standing position 1 Check that any structure or equipment used for support can bear at least 10 times the weight of all the panels clamps cables auxiliary equipment etc that will be placed on it 2 Make sure that there will be at least 30 cm 11 8 in of free space and unrestricted airflow to and around the heatsink fins in the base of the panels 3 Check that there are no combustible materials within 0 5 m 20 in of the panels when installed and that there are no flammable materials nearby 4 Fasten panels securely so that they cannot tip or fall Panels are not safe if left free standing Flying from a truss bar or other structure See Figure 3 One vertical curtain with LC Plus 1140 panels suspended from each other may contain a maximum of eight panels One vertical curtain with LC Plus 2140 panels suspended from each other may contain a maximum of six panels These limits apply to panels both when suspended in an upright position and when suspended on their sides N N An unlimited number of curtains of panels may be installed alongside each other O O To fly panels from a rig or other structure 1 Check that the structure can bear at least 10 times the weight of all the panels clamps cables auxiliary equipment etc that it will have to s
20. ent video framerate in frames per second Eth IDDO Ethernet port 1 link speed none 100 1000 Ethe nonE Ethernet port 2 link speed none 100 1000 rEd IDO Red test pattern intensity O 100 Dro IDO Green test pattern intensity O 100 bLUE IDD Blue test pattern intensity O 100 LESE FULL IDO Full white test pattern intensity O 100 CYCL IDO Cycle between red green blue white and off intensity O 100 ScAn IDD Illuminate one row and one column of pixels at a time intensity O 100 gr Hd IDO Display a vertical scrolling gradient from black to white intensity O 100 FLIP Rotate the control panel display 180 Table 5 Control menus Resetting and rebooting panels If it becomes necessary to reset an LC Plus panel it is possible to force a normal reboot which causes the panel to reset and start up as it normally would when power is applied or a factory reboot which causes the panel to start up the original factory programmed firmware The factory reboot is a fail safe way to ensure the panel can be started up if there is a problem with the most recently uploaded firmware It should not be required during normal operation Normal reboot Press all four control panel buttons simultaneously The display will show r 5EE Release the buttons within five seconds The panel will boot up normally as though power has just been applied Factory reboot Press and hold all four buttons for 5 seconds o
21. er a single phase 200 240 VAC system or in a 3 phase delta system or split phase mid point neutral system using two phases to obtain 200 240 VAC Power and current figures are given in Typical power and current on page 25 Allow a sensible safety margin when calculating the AC mains power distribution circuits current headroom required for an LC Plus installation Each LC Plus 2140 panel is protected by one 10 AT slow blow main fuse when connected using the supplied single phase power cables and protected by two 10 AT slow blow main fuses when connected using the supplied 2 phase power cables Fuses are not user replaceable Inrush current Inrush current peaks are unlikely to occur at exactly the same time in multiple panel installations and only have a duration of a few microseconds but bear in mind that inrush current when powering on may cause unintentional tripping of circuit breakers especially if these have poor resistance to momentary current peaks LC Plus user manual Power connection Power is supplied to the panel via the input socket see D in Figure 1 on page 6 This socket accepts an Amphenol C016 20 D 003 100 12 cable connector female IP67 rated Power can be relayed to another LC Plus panel via the throughput socket see E in Figure 1 on page 6 This socket accepts an Amphenol C016 20 H 003 100 12 cable connector male IP67 rated Warning A maximum of five LC Plus 2140 panels in total or ten LC
22. es from other sources can be used as an alternative but they must be 3 conductor Hypalon or neoprene rubber jacket approved for a current of 16 A and temperature of 90 C 194 F minimum Replacement cables must also be 16 AWG minimum and UL listed in North America or have conductor size 1 5 mm minimum in other regions Socket outlets used to supply LC Plus panels with power or external power switches must be located near the panels and easily accessible so that the panels can easily be disconnected from power e Do not connect any other device than other LC Plus panels to the power output throughput connector in the base of the LC Plus Safety Information 3 Gr E Connect no more than five LC Plus panels in total to AC mains power in one chain using the power output throughput connectors in the base of the product When using the product in a wet location use only the Amphenol IP67 rated connectors supplied by Martin and specified in this manual Seal all unused connectors with their IP67 rated caps Before using the product check that all power distribution equipment and cables are in perfect condition and rated for the current requirements of all connected devices Do not use the product if the power cable or a power plug is in any way damaged defective or showing signs of overheating Do not attempt to remove any LED tube or open any cover Refer any service operation not described in this manual to a qualified technician P
23. gure 9 Pass the cable through the cable nut correct gasket for the cable diameter clamping ring and back shell 4 Strip 18 19 mm 0 70 0 75 in of cable jacket and then strip 7 8 mm 0 27 0 31 in of insulation from each conductor as indicated for screw contacts with internal cable retention in Figure 9 Twist the bared strands at the end of each conductor to strengthen them 5 Fasten the conductors in the cable into the screw terminals in the male or female contact insert as follows 2 When installing an Amphenol C016 series power connector in a single phase system Fasten the green yellow ground earth conductor in the screw terminal marked Drain or QD Fasten the blue neutral conductor in the screw terminal marked 2 Fasten the brown live conductor in the screw terminal marked 1 Do not connect anything to the terminal marked 3 LC Plus user manual When installing an Amphenol C016 series power connector in a 2 phase system Fasten the green yellow ground earth conductor in the screw terminal marked Drain or D Fasten the black phase 1 conductor in the screw terminal marked 1 Fasten the white phase 2 conductor in the screw terminal marked 3 Do not connect anything to the terminal marked 2 6 Tighten the internal strain relief clamp onto the cable 7 Tighten the back shell onto the male or female contact insert 8 Tighten the cable nut onto the back shell Power plugs and power outlet sockets A po
24. ingle phase power use the supplied single phase power input and throughput cables with black connector shells When connecting to 2 phase power use the supplied 2 phase power input and throughput cables with blue connector shells Warning LC Plus panels do not have a power on off switch They are powered on as soon as mains power is applied to the power input connector and remain powered on until mains power is shut down at source or disconnected from the panel The external power switch or power outlet socket must be located near the LC Plus and easily accessible so that power to the LC Plus can easily be shut down or disconnected if necessary Important Connect the panels in the installation and the P3 controller to AC mains power at the same outlet point in the power distribution circuit or you may experience ground earth loop problems or create differences in potential that can damage devices Damage caused by differences in potential if devices are incorrectly connected to power is not covered by the product warranty Power and fuses 12 Warning Fuses are not user replaceable Contact Martin Professional for assistance if you suspect that a fuse has blown Warning Double pole neutral fusing The LC Plus features an auto sensing switch mode power supply that accepts 200 240 V nominal AC mains power at 50 or 60 Hz Connect the panel to power that is within this voltage range only The LC Plus can be connected to mains power in eith
25. locking ruggedized IP67 rated connectors Po data MOUE xad ey d eq a qaid idu Quick locking ruggedized IP67 rated RJ45 connectors Electrical AC DOWOL EE 200 240 V nominal 50 60 Hz l OWOF SUDDIV t UE EE Integrated auto sensing multi voltage Main fuse not user replaceable LC Plus 2140 single phase power 10 AT 2 phase power 2 x 10 AT Typical power and current LC Plus 2140 ZOO IN WOO e KEE EE 319 W 1 6 A PF 0 978 200 V OO EZ geg naa toe ere Eee Mae eos de DE AREE ER BU dried 319 W 1 6 A PF 0 978 290 V S0 FZ s 238 PARE RR dd ROUES dae AE UR A RAE 0 GS 320 W 1 5 A PF 0 967 eA VDO HZ eese dee oet E aa 323 W 1 4 A PF 0 965 Measurements made at nominal voltage with all LEDs at full intensity Allow for a deviation of 10 Thermal EE eben Sada o un aiat ER hee fadt ud eames Convection Maximum ambient temperature T4 max 50 duty cycle full white 1 sec on 1 sec off 40 C 104 F Minimum ambient temperature Ta mm 20 C 4 F Total heat dissipation LC Plus 2140 calculated 1160 BTU hr Approvals HO A O A EN 60825 1 EN 60950 1 SEN aari nest a ts de EN 55022 EN 55024 EN 61000 3 2 EN 61000 3 3 IJS salety leie Le e Le NEE ANSI UL 60950 1 Canadian safety pending 0 00 cece eee eee ees CAN CSA 60950 1 03 Included Items Packed with cardboard box models Four Prolyte CCS6 conical couplers elles 4 x P N 21021150 Eight threaded spigots for CCS6 conical c
26. lugs used for P3 signal input and out throughput Important Power all panels and devices off while making connections To connect the P3 link 1 Plug an Ethernet patch cable running from the P3 100 System Controller s P3 signal output socket into one of the RJ 45 Ethernet ports on the first LC Plus panel it does not matter which port you use as both P3 connectors can be used for input and output In outdoor or wet locations an IP67 rated Amphenol RJF RB 6 housing must be installed on the RJ 45 plug 2 Continue connecting panels to the P3 link in a daisy chain by running Ethernet patch cables from the first panel s Ethernet 2 socket to the next panel s Ethernet 1 socket respecting the layout and guidelines given earlier in this section 3 When you have made all P3 and power connections set up the panels as described in the P3 100 user manual 4 Any connectors that are not being used must be sealed with their caps at all times 5 The system is now ready for power to be applied 18 LC Plus user manual Configuration and testing This section covers the needs of the installer and technician only It explains the options available for configuration and testing of LC Plus panels but it does not explain how to allocate addresses to panels or the options available for displaying video For details of these see the P3 100 System Controller user documentation When repacking panels in a Martin flightcase after operation follow the in
27. n s expertise and product knowledge in a partnership that will ensure the highest level of performance throughout the product s lifetime Please contact your Martin supplier for details It is Martin policy to apply the strictest possible calibration procedures and use the best quality materials available to ensure optimum performance and the longest possible component lifetimes However LEDs are subject to wear and tear over the life of the product resulting in gradual changes in color and overall brightness over many thousands of hours of use The extent of wear and tear depends heavily on operating conditions and environment so it is impossible to specify precisely whether and to what extent LED performance will be affected However you may eventually need to ask Martin Professional to replace LED tubes if LED characteristics are affected by wear and tear after an extended period of use and if you require panels to perform within very precise optical and color parameters The fuses marked F1 and F2 on the PCB may only be replaced by Martin Service or its authorized agents These fuses must be 10 A 250 V HBC type The LEDs will not be affected by weather conditions as they are sealed inside acrylic tubes However the outer surfaces of the acrylic tube will be exposed to the elements dirt dust etc Cleaning Do not use abrasive caustic or solvent based products for cleaning as they can cause surface damage To clean an LC Plus panel
28. ng torque without internal cable retention 22 CN 1 PE 2mm 2 end splice recommended internal Strain relier NWS i 15 2Nm additionally male contact piu included gasket insert with locking ring cable nut tightening torque l 1 5 2 Nm tightening torque 0 5 Nm female contact insert with locking ring Content in this illustration is copyright OAmphenol Tuchel Electronics GmbH and used by permission These illustrations may not be reproduced in any form without the written permission of Amphenol Tuchel Electronics GmbH Figure 9 Amphenol power cable connector assembly instructions The Amphenol C016 ecomate series power cable connectors used with the LC Plus accept power cable from 6 mm 0 24 in to 9 mm 0 35 in diameter when fitted with a standard cable gasket or from 9 mm 0 35 in to 12 5 mm 0 5 in diameter when fitted with an optional heavy gauge cable gasket If you need to install an Amphenol C016 series cable connector on a power cable for connection to an LC Plus panel 1 Ensure that the power cable is UL listed 16 AWG minimum in North America or 3 x 1 5 mm minimum in other regions 3 conductor Hypalon or neoprene rubber jacket type approved for a current of 16 A and a temperature of 90 C 194 F minimum 2 Obtain a female cable connector Amphenol C016 20 D 003 100 12 for power input or a male cable connector Amphenol C016 20 H 003 100 12 for power out throughput 3 See Fi
29. o output can be used as a video source P3 link requirements in large installations A single P3 100 system controller can drive up to 400 LC Plus 2140 panels up to 800 LC Plus 1140 panels or any combination within a limit of 500 000 pixels provided that Ethernet switches are used to split and or amplify the P3 signal as described in this section Using Ethernet switches to split the link into chains See Figure 11 If the LC Plus installation consists of more than 50 panels you must first run the P3 signal output from the P3 100 System Controller to a 1 GB Ethernet switch Divide the panels into separate daisy chains with no more than 50 panels on any single chain and use the outputs from the Ethernet switch to send the P3 signal to each chain Figure 11 shows a 1 GB Ethernet switch on the P3 link as an example but the switch is not necessary if there are 50 panels or less in the installation Using Ethernet switches to extend the link See Figure 11 The maximum permitted cable length between any two devices on the P3 link before a signal amplifier is required is 100 m 328 ft if good quality Ethernet cable is used for the link A 1 GB Ethernet switch on the P3 link is an ideal signal amplifier If the P3 link will exceed the 100 m cable length limit at any point in the installation insert a switch to boost the signal If necessary more switches can be added each time the link reaches the 100 m limit Figure 11 shows the 1 GB Etherne
30. oad free of charge from the Product Support area at www martin com Related Products Martin Maxedia PRO System Media Server EU P N 90732520 Martin Maxedia PRO System Media Server US P N 90732530 Martin Maxedia Compact System Media Server EU US P N 90732540 Ordering Information LC Plus 2140 Flightcase lille RR I P N 90354101 LC Plus 2140 Cardboard box P N 90354102 Martin P3 100 System Controller llli P N 90721010 Specifications subject to change without notice Disposing of this product Martin products are supplied in compliance with Directive 2002 96 EC of the European Parliament and of the Council of the European Union on WEEE Waste Electrical and Electronic Equipment as amended by Directive 2003 108 EC where applicable Help preserve the environment Ensure that this product is recycled at the end of its life Your supplier can give details of local arrangements for the disposal of Martin products 26 LC Plus user manual r Martin www martin com e Olof Palmes All 18 e 8200 Aarhus N e Denmark Tel 45 8740 0000 e Fax 45 8740 0010
31. old use This product presents risks of severe injury or death due to fire hazards electric shock and falls Read this manual before installing powering or servicing this product follow the safety precautions listed below and observe all warnings in this manual and printed on the product If you have questions about how to operate the fixture safely please contact your Martin supplier or call the Martin 24 hour service hotline on 45 8740 0000 or in the USA on 1 888 tech 180 PROTECTION FROM ELECTRIC SHOCK Connect the product to AC mains power within the range 200 240 V nominal at 50 or 60 Hz only Disconnect the entire installation from power and ensure that power cannot be reconnected even accidentally before carrying out any installation or maintenance work Disconnect the product from power when not in use and if you suspect that a fuse has blown e Always ground earth the product electrically Use only a source of power that complies with local building and electrical codes and has both overload and ground fault earth fault protection Connect LC Plus panels to AC power using only 16 A rated industrial Type B power plugs and socket outlets that comply with IEC 60309 or a comparable national standard and provide an electrical connection to ground protective earth Connect LC Plus panels to AC power and to each other using the 16 A rated UL listed 16 AWG cables supplied by Martin for this product Replacement power cabl
32. or top rails See Figure 7 Continue hanging panels attaching them with conical couplers A secured with threaded spigots B as shown in Figure 7 As soon as a panel is added to an array secure it with two safety attachments Figure 6 Panel to panel safety cable attachment Figure 7 Conical coupler system Physical installation 11 AC power Warning The safety of the installation is the responsibility of the installer Read Safety Information on page 3 before creating an installation or connecting an LC Plus panel to AC mains power Disconnect the entire installation from power before carrying out installation work Warning A maximum of FIVE LC Plus 2140 panels in total or TEN LC Plus 1140 panels in total may be interconnected using power throughput connectors to form one chain that draws power via the first panel s power input cable If you do not respect these limits you will overload cables and components and create a serious safety hazard Each time you reach the maximum permitted number of interconnected panels in one daisy chain and want to supply more panels with power you must create a new daisy chain that draws power from a separate power outlet Warning For protection from electric shock the panel must be grounded earthed Power distribution circuits must be fitted with a current overload fuse or circuit breaker and ground fault earth fault protection Warning When connecting LC Plus panels to s
33. ouplers in LC Plus panels 8 x P N 08330127 8 mm hex key for threaded spigots c 2 P N 50520619 5 m 16 4 ft AWG 16 power input cable with IP67 rated input connector EU color coded for single phase power mmput eee eee P N 11521030 US color coded for 2 phase power inpUt c 2 2 P N 11521034 1 5 m 4 9 ft AWG 16 power throughput cable with IP67 rated connectors EU color coded for single phase power P N 11521031 US color coded for 2 phase power P N 11521033 2 5 m 8 2 ft Ethernet patch cable with IP67 rated RJ 45 connectors P N 11840146 1 5 m 4 9 ft Ethernet patch cable with IP67 rated RJ 45 connectors P N 11840140 Safety and Installation manual P N 35000218 Specifications 25 Packed with flightcase models Sixteen Prolyte CCS6 conical couplerS 0 00 cee ee eee eee 16 x P N 21021150 Thirty two threaded spigots for CCS6 conical couplers in LC Plus panels 32 x P N 08330127 8 mm hex key for threaded spigots eee ee eens P N 50520619 Four 5 m 16 4 ft AWG 16 power input cables with IP67 rated input connector EU color coded for single phase power mput ee 4 x P N 11521030 US color coded for 2 phase power input 000 e eee eens 4 x P N 11521034 Four 1 5 m 4 9 ft AWG 16 power throughput cable with IP67 rated connectors EU color coded for single phase power 4 x P N 11521031
34. r longer The panel will display EH E When the buttons are released the panel display will alternate between FAct and L old a few times to indicate that the factory firmware is about to be loaded The panel will then boot the original factory programmed firmware Note that performing a factory reboot will only cause the panel to boot the factory firmware once At the next power cycle or reset a normal reboot will be carried out unless all four buttons are held in to force a factory reboot again Configuration and testing 21 Service and maintenance Warning Disconnect the panel from power and ensure that all connectors are sealed either with their corresponding cable connectors or with their caps or isolate the entire distribution circuit from power before cleaning Refer any service operation not described below to service technician approved by Martin Professional Removing any cover or LED tube may cause a safety risk or unsatisfactory performance and will invalidate the product warranty The user will need to carry out periodic cleaning and it is also possible for the user to update the LC Plus firmware quickly and easily from the P3 100 System Controller All other service operations must be carried out by Martin Professional or its approved service agents Installation on site service and maintenance can be provided worldwide by the Martin Professional Global Service organization and its approved agents giving owners access to Marti
35. s Panels communicate with each other to determine which devices are connected on the P3 link so the P3 command receive LED middle left can indicate that the panel is receiving commands another panel as well as from a P3 system controller Panel address and status messages in the display panel The following information appears in sequence in the display panel at start up Display Indication book Controller hardware is booting displayed briefly so may not even be seen r5EE Panel firmware is resetting e HU Panel model number either 2140 or 1140 PLUS Identifies panel as LC Plus Table 4 Start up display messages The boot process generally takes approximately 4 seconds When it is completed the panel displays its address It will continue to display its address permanently unless the control menus are activated 20 LC Plus user manual Control menus The following menu commands and options are available in the control panel Menu Item Options Notes Addr 4999 Set panel s display address can also be set from P3 100 Controller LEP CHOC Main PCB temperature degrees Celsius 82 F Main PCB temperature degrees Fahrenheit F U 1 Panel firmware major and minor version numbers i Panel firmware point version numbers i nfo LYPE e IHO Panel type 2140 or 1140 UPSr Panel variant upgraded standard LC panel or LC Plus panel FPS BO Curr
36. structions in the flightcase see LC Plus flightcases on page 8 Control panel display and status indicators Basic configuration status checking and testing without a P3 100 connected can be carried out using the control panel and LED display on the back of the frame base Five LEDs give information about panel and system status Using the control panel and control panel display R 1 e ETHE PREV NEXT p eActive MENU ENTER e ETHER 2 MENUS e Figure 12 Control panel and control panel display The panel s address appears in the 7 segment 4 character LED display when an LC Plus panel is powered on The control panel is used as follows To enter the control menus see Table 5 hold MENU pressed in for one second The red status LED at the bottom right of the panel will flash quickly to indicate that you are about to enter the control menus After a second the panel address will fade out and the first control menu Addr will fade in The red status LED at the bottom right of the panel will light constantly To scroll between menus or options in menus such as values press PREV and NEXT To select a function or submenu or to confirm a selection press ENTER To escape a function or menu press MENU If no buttons are pressed for 25 seconds the menu indicator LED will start flashing slowly If no buttons are pressed for a further 5 seconds the panel will automatically exit the control menus When exiting the men
37. t switch inserted between two panels on the P3 link as an example only the switch can be inserted in any position on the link where the cable length between any two devices would exceed 100 m More expensive sophisticated switches tend to carry out additional processing that can cause latency You should therefore choose a relatively cheap unmanaged gigabit Ethernet switch LC Plus user manual P3 system layout schematic overview P3 100 System Controller P3 signal Analog video Analog video Monitor 1GB Ethernet switch required if installation exceeds 50 panels Max 50 panels per daisy chain 1GB Ethernet switch required if cable length exceeds 100 m p JL me cable Figure 11 Schematic diagram of P3 system connections P3 communication link 17 Connecting the P3 link Warning For outdoor or wet location use use Amphenol RJF RB 6 housings as supplied with the panels on all the RJ 45 p
38. u system either manually or automatically the menu display will fade out and the panel address display will fade in The red status LED at the bottom right of the panel will now be off to indicate that the control menus are disabled Configuration and testing 19 RGB overall status LED One overall status RGB LED on the left of the display panel gives at a glance indication of panel status This LED indicates the following states Color Output Indication Action required Busy e g booting up or writing to Wait a moment for normal operation ee constant flash memory to be resumed Red Constan Error The panel has encountered a Perform a factory reboot followed by fatal error and can not run a firmware upload Red Flashin Disconnected A system controller Connect a system controller to the H could not be found network Ready A system controller is present Configure the system controller to elem zx on the network use this panel Running A system controller is using Green Constant this panel None Red status LEDs Table 2 RGB status LED Four small red status LEDs located around the display panel indicate the following states Marking Location Indication ETHER 1 Top left Ethernet port 1 link flashes during activity ACTIVE Middle left Receiving P3 commands ETHER2 Bottom left Ethernet port 2 link flashes during activity MENUS Bottom right Control menu system active Table 3 Red status LED
39. upport 2 See Figure 4 Check that the structure will not flex under the weight of the panels Hanging panels from a structure that is not straight will place a strain on panels Damage caused to panels by mechanical stress is not covered by the product warranty 3 Check that there are no combustible materials within 0 5 m 20 in of the panels when installed and that there are no flammable materials nearby 4 Install two conical couplers in the top of the first panel and install two rigging clamps or eyebolts on the couplers 5 Block access under the work area Working from a stable platform hang the panel by fastening the rigging clamps or a KAKAKAASD eyebolts to the truss or structure H Figure 4 Avoiding stress on panels A A A A
40. wer P N 11521031 e 4x 1 5 m 4 9 ft power throughput cables with IP67 connectors for 2 phase power P N 11521033 e 4x 2 5 m 8 2 ft Ethernet patch cables with IP67 RJ 45 connectors P N 11840146 e 4x 1 5 m 4 9 ft Ethernet patch cables with IP67 RJ 45 connectors P N 11840140 LC Plus Installation and Safety Manual P N 35000218 Threaded spigots for conical couplers in the Martin LC Plus are not interchangeable with the threaded spigots for the standard Martin LC Series Do not throw away the protective shock absorbing materials from the flightcase when you unpack panels The protective materials will be needed when panels are repacked in the flightcase Using for the first time Before applying power to the panel e Carefully review Safety Information on page 3 e Check that the local AC power voltage is within the ranges listed on the serial number label and in Power and fuses on page 12 e To supply the panel with power use the supplied power cable or install an Amphenol C016 20 D 003 100 12 connector on a UL listed minimum 16 AWG or 1 5 mm SJT or better power cable as described in Power connection on page 13 LC Plus flightcases Important Important To ensure that LC Plus panels can withstand the shocks that normally occur during transport they must be packed in a Martin flightcase and transported in an upright position following the instructions in the flightcase see Figure 2 Damage cause
41. wer plug must be installed on the power input cable so that you can connect LC Plus panels to AC mains power Install a grounding type earthed industrial 3 prong type B plug see Figure 10 that complies with IEC 60309 or a comparable national standard and is rated 16 A minimum and use corresponding power outlet sockets Follow the plug and socket manufacturer s instructions and all locally applicable laws and electrical safety codes When installing a power plug in a single phase system e Connect the green yellow ground earth conductor to the terminal marked CD or L e Connect the brown live conductor to the terminal marked L e Connect the blue neutral conductor to the remaining terminal When installing a power plug in a 2 phase system Figure 10 Industrial IEC 60309 type B power plug e Connect the green ground earth conductor to the terminal marked S or L e Connect the black phase 1 conductor to the terminal marked L e Connect the white phase 2 conductor to the remaining terminal Wire color Wire color EU color code US color code Pin Symbol Screw US brown black live L yellow or brass blue white neutral N silver yellow green green ground earth D or L green Table 1 Wire colors and pin identification AC power 15 P3 communication link LC Plus series panels communicate using the Martin M P3 signal format via Ethernet cable The P3 signal contains both video data and command signals