Home
QTA Access Point Configurator User Manual ver 1.0
Contents
1. 1 3 QTA Check in Node function The purpose of Check in Node is to read announcement data using a Bluetooth Low Energy connection from all QTA Tracers that is in the area and send the information to QTA Web Portal This information is used on the Web Portal to display the status of the blood bag and where the QTA Tracer is located 2 Installation Visit Apple App Store to download and install the free App QTA Check in QT TRACER 4 Manufactured by M aM TRIDENTIFY 3 3 1 eeecc TELIA 3G 1009 O Q al QTA Checkin Usage Register QTA Check in Nodes System administrators only To register a QTA Check in Node on the QTA Web Portal follow these steps pu ep iPad Settings iCloud E post kontakter kalendrar Anteckningar P minnelser Meddelanden FaceTime Kartor Safari On iPad choose Settings Scroll down to QTA Check in Node Make sure Server location is correct http www qtatracersystem com Copy CIN UUID if the field is empty first open the Check in Application on the 81 a QTA Checkin QUEUE Seconds between updates 300 Seconds between uploads 300 Number of upload attempts 576 ABOUT Version PuffinPack Af Developed by Copyright 2013 by Tridentify AB All rights reserved Figure 2 QTA Check in Node Settings TRACER QT SYSTEM QUALITY TRACEABILITY ACCESSIBILITY 5 Open your web browser and go to www qtatracersystem com click on
2. 3 in the upper right corner to sign in with user id and password provided by the system administrator 6 Paste the CIN UUID into the Node unique id text field 7 Click on Search and Edit button Figure 3 QTA Web Portal Node registration s E ac2db784ee37 Node unique id Description Location Node type LeifAP 1 Leif kontor QTA Access Point Windows Edit Delete Leif AP Test 1 0 0 7 installer Leif kontor QTA Access Point Windows Edit Delete Leif Test CIN 1 Leif kontor Check In node IPad Edit Delete Leifs CIN2 Leif kontor Check In node IPad Edit Dele Magdslens AP 1 Enrisv QTA Access Point Windows Edit Delete Msttiss 1 0 0 7 Bok OTA Access Point Windows Edit Dele Mattias AP 1006 Bokskogen QTA Access Point Windows Edit Delete Msttiss iPhone 1 2 10 Bokskogen Chec In node IPad Edit Delet Showing 1 8 of 8 hits lt lt lt 1 of 1 gt gt gt 5 Manufactured by 4 TRIDENTIFY 8 Fill in the form Make sure the description and Location makes it easily identified on the Portal Id c34ss0e2 Ged2 4914 9726 9ee185820f02 Organization id 13001 Node type QTA Access Point Windows Description Location Address 1 Address 2 City Postal code Country Sweden Time limit for object on queue 0 Time between uplosd sttempts 0 Max number of upload attempts 0 Node version 1 0 0 6 Crested date 2013 08 30 08 40 55 Modified date 2013 09 2
3. 8 08 13 41 Save Cancel Figure 4 QTA Web Portal Node form 3 2 Operation On the iPad press the Check in icon The application must be visible on screen to function It cannot operate in the background ee TELIA 3G 13 18 nd 95 96 mm eee TELIA 3G 13 27 93 m QTA Tracers 0 QTA Tracers 2 QTA78C5E57279E7 Sent V Bat 100 Blood ok y 0 05 min ago Blood rel y QTA78C5E5727D9C Sent V Bat 100 Blood ok X 0 18 min ago Blood rel yY Information displayed on Check in Node e Tracer id e Battery level e Time since announcement was registered e Sent status e Blood status e Blood release status Information is automatically sent to Web Portal where expiration date and Node location is displayed along with the above information and data from blood bag Manufactured by TRACER 6 OTA sen 194 TRIDENTIFY QUALITY TRACEABLITY ACCESSIBILITY
4. User manual OTA Check in Node QTA stem Version 1 0 QTA Check in Node Table of contents 1 Introduction 3 1 1 System Requirements QTA Check in Node 3 1 2 QTA Tracer System OVErVICW ccccccceeeecceeeeeeeceeeaeeeeeeseeeeeeeeeas 3 13 QTA Check in Node function 2u000220200ssnnnnnneennnnnnneenennnnn 4 Installation 4 Usage l 3 1 Register QTA Check in Nodes System administrators only 5 3 2 OPE aO RETE 6 TRACER 2 Manufactured by QTA sin Aba TRIDENTIFY ACEABLT QTA Check in 8 Node 1 Introduction The Check in Node reads announcement data from QTA Tracers and send the information to QTA Web Portal 1 1 System Requirements QTA Check in Node CIN running on following platforms iPad mini WLAN iPad 4th generation or later GPRS Bluetooth 4 0 iPhone 4s or later WLAN GPRS Bluetooth 4 0 1 2 QTA Tracer System overview The QTA Tracer system consists of a PC with the QTA Tracer System software installed a Bluetooth USB dongle a Barcode reader and QTA Tracers For full functionality the system also includes QTA Check in Nodes QTA Readers and the QTA Web Portal Figure 1 displays the QTA Tracer system QTA Access Point Config QTA Web Portal QTA Check In Node QTA WEB PORTAL QTA Tracer Figure 1 The QTA Tracer System Manufactured by TRACER A QTA sisten 194 TRIDENTIFY QTA Check in Node
Download Pdf Manuals
Related Search
Related Contents
Barcode Printer and Scanner Hardware Setup Instructions Betriebsanleitung Controlador programable UNITED NATIONS WORLD HEALTH M26-M50 - Jofemesa GPS Receiver A1029 manual do proprietário - Petrotec Equipamentos para Construção Hamilton Beach 8300 hair dryer 第 43回定時株主総会招集ご通知 Copyright © All rights reserved.
Failed to retrieve file