1. 84 SECTION 5 Command Line Interface Lock LOCK E Command Format Command code SP Lock Code K SP Option 1 SP SP Option n 4 1 10 Description Specifies a lock type of an password memory area intended to be controlled with double digits code shown as below 4 Access pwd EPC memory emory User memory Lock Code R W Write pwd perma perma write lock lock Ok Type of lock 0 0 Cancels temporal lock Option code Available Optional Value Communication sequence SOC Single Once Number of antenna Specifies order of antenna operation with figure 1 4 max 9 characters Process time out msec 0 or from 100 to 5 000 in 10msec increments Additional tag information Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail 73 Access password Specifies a password with 8 digit hex number 32 bit word It is essential unless the value in the area of tag Access Password is zero It is active only when the area specified by tag is locked for read and write CET UHF RFID System User s Manual SECTION 5 Command Line Interface E Response Format Command code Response code SP Tag count SP TIF information SP
2. Example 4 When indicated address can not supported Tx RDDT 0 0 8 lt LF gt Rx RDDTOOO0 000 LF No count data is returned Example 5 When an incorrect address 1000 is specified Tx RDDT 0 1000 1 ant 123 LF Rx RDDT1412 LF The command data error Code 1412 is returned Example 6 When an error has occurred during communication process Tx RDDT 0 0 1 ant 123 LF Rx RDDT7012 LF The error code Code 7012 is returned UHF RFID System User s Manual 81 SECTION 5 Command Line Interface Write Data WTDT E Command Format Data Pointer Option 4 1 1 1 1to3 1 n 1 n 1 1 n Description Specifies memory bank of Gen2 tag 0 Reserved Area Memory bank 1 EPC Area 2 TID Area 3 User Area Specifies memory address intended to access in the memory bank 0 255 Specifies hexadecimal number in word 16 bits increments 1 32 Option code Available Optional Value 5 Communication sequence SOC Single Once ant Number of antenna Specifies order of antenna operation with figure 1 4 max 9 characters Process time out msec 0 or from 100 to 5 000 in 10msec increments Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail
3. Tag protocol 1 Gen2 UHF RFID System 92 User s Manual SECTION 5 Command Line Interface E Response Format Response code SP Tag count SP TIF information E STR 4 4 1 3 1 n Item Description Response code 0000 Normal end For other Response codes refer to Hesponse Code List 71 Tag count Count of locked tag s TIF information Tif information specified with command Each optional value for tif information lines with comma separation M Secure function is supported by certificication number at 001AHB1004 001PVAB1002 The reader which certification number is 001AHB1001 can not use this function Also Secure function can only use for the RF tags which supports ww secure RFID protocol The standard EPC global Class1 Generation 2 RF tags does not work U m O T eounoes 10 aAIsn ox3 UHF RFID System User s Manual 93 SECTION 5 Command Line Interface Lock Read Block LKRB E Command Format Command code SP Block SP User password SP Lock code SP Option 1 SP SP Option n L K R B number Item Description opecifies memory address of the targeted area in the user memory 1 5 Specifies a password for each user area User password The password should be same as the password set previously
4. 58 MEMO UHF RFID System User s Manual SECTION 5 Command Line Interface Control method 60 Communication Sequence 61 Command Response Format 66 Communication Command 76 Communication command Exclusive commands for secure tag 89 o Setting Command 101 Control Command 119 Undefined Command 128 UHF RFID System User s Manual 59 SECTION 5 Command Line Interface Control method Control by command The reader writer s operation is directed by transmitting the command from connected host device It replies the result of executing the command as a response In the operation mode all operation is controlled by the command according to the content of the transmitted command ex Read Write of ID of RF Tag and data Setting of function of RF Tag Setting of communication condition Setting of Reader Writer Host Device ex Personal computer Command esponse Result Operation condition setting RF Tag Reader Writer Communication between External input External output Antenna and RF Tag FLTIDPETITETLTIITIM SO Cn o Functions and Control ex Processing stop Output setting o m O T Command and Response Flowchart In the operation mode the command is transmitted from host device and it replies from Reader Writer the response of the processing result There is a state of the following commands and the respons
5. 73 Specifies a password with 8 digit hex number 32 bit word It is essential unless the Access password value in the area of tag Access Password is zero It is active only when the area specified by tag is locked for read and write Data pointer Written data m O T Tag protocol 1 Response code SP Tag count SP TIF information SP SP TIF information 4 4 1 3 1 n 1 1 n Description 0000 Normal end For other Response codes refer to Response Code List 71 Tag count Count of written tag s Response code Tif information specified with command Each optional value for tif information lines with comma separation TIF information UHF RFID System 82 User s Manual SECTION 5 Command Line Interface Command Response Example Write Data WTDT WTDT S mbk S apt S WriteData S options L F S Space code mbk Memory Bank dpt Data Pointer WriteData Data to be written options When it is necessary the option is specified WTDT RC S CNT S ITM 1 S ITM n LF S Space code RC Response Code CNT Tag Count ITM n Items indicated by TIF option Items are delimited by a comma Note If EPC PEP PER are specified for TIF option EPC data shall be the data before rewrite If data length is zero during EPC specification data shall
6. T Tag Information Specifies one or more items as additional information of tag communication results that are output in the response Specified item s shall be returned according to the specified order with commas ANT An antenna number which reads the tag first CNT The count of tag read EPC EPC code only PEP PC bits and EPC code PER PC bits EPC code and CRC LVL Receiving level of signals sent from the tags 1 For ID read EPC PRP PER determines the EPC data type to be returned For ID write or Data write if EPC PEP PER is specified EPC data before rewriting shall be returned If EPC data length is 0 it will be 4 asuodsay puewwoy Password Specifies the password data with 32 bit 8 digit numbers in hexadecimal format for access pwd of ID Write command Data Read command Data Write command and Lock command 00000000 and Kill password for Kill command 0x not required XXXXXXXX For ID Write Data Write or Lock if this option is omitted or specified 00000000 Access password shall not be used If Access password of the Tag is 0x00000000 the tag can be processed For Kill command the Access password shall not be 0x00000000 If so 7Fxx error occurs Tag Protocol opecifies the number s that indicates the protocol type Multiple numbers can be specified 1 Class1 Generation2 UHF RFID System User s Manual T3 SECTION 5 Command Line Interface
7. 2 Communication monitoring function that reduces the installation time A tag communication testing function an on site environmental monitoring function a noise check for each channel and an error logging function are equipped These functions show the status of radio waves and enable you to verify performance of tag reader or analyze phenomena that may change depending on on site RF environment soJnjeo OMRON omRon Latest Error Logging History of Error Logging 1 2 11 12 21 22 31 32 41 42 49 50 3 Multiple LED operation displays The multiple LED indicators show the reader operation status clearly and simply so that you can understand the status and handle an error quickly if it happens to occur 4 Automatic antenna detection This function enables you to check the connection status of antennas when a command is executed It helps to detect an error or problem of antenna s or wiring 3 Expandability applicable to broad usage Firmware upgradable Via Web browser on the PC you can upgrade its firmware It means that the functions are expandable UHF RFID System User s Manual o m O SECTION 1 Features and System Configuration System Configuration System example for logistic tracking application V750 series Radio wave propagative RFID system is ideal for long range communication and for the system construction used in the production process or
8. Command code Response code SP SP Ch2 SP Ch9 N O S Noise Level Noise Level Noise Level 0000 Normal end Response code For cer Response codes refer to Response Code List 1 71 Noise level of each channel The noise level of one channel is displayed by eight digits XXXXXXXX The larger the value is the higher the noise level is When the value at the noise level is converted it is possible to convert it by the following expression 20 Log 10 Noise Level gt 135 dBm This conversion is a standard Therefore it uses it as a rough estimate Command Response Example Noise level check NOIS NOIS S Mode S Antenna lt LF gt S Space code alpine Mode noise level measurement mode 0 fixed Antenna the port number of antenna 1 4 that is to check the noise level U m O T 041u02 NOIS RC S ch1 and ch2 S ch3 and ch4 S e S ch49 and ch50 LF RC Response Code S Space code ch1 and ch2 to ch49 and ch50 Noise level of each communication channel The response data has a noise level every 2channels 1MHz band 1ch and 2ch 3ch and 4ch A9ch and 50ch 1ch means 902 75MHz 2ch means 903 25MHz 3ch means 903 75MHz 50ch means 927 25MHz To convert the response data to dBm put them into the following formula 20 log10 response value 135 The derived value should be used only as a g
9. T 10 99 o m O T 10 spueuiuioo 2 100 SECTION 5 Command Line Interface Write Password WTPW E Command Format Command code SP Block SP User password SP Option 1 SP SP Option n Ww T P WwW number Item Description Block number Specifies memory address of the targeted area in the user memory 1 5 Specifies password for each user area The password should be same as the password set User password previously in the password area corresponding to the block number set above Option code Available Optional Value Number of antenna Specifies order of antenna operation with figure 1 4 max 9 characters 0 or from 10 to 2550 in 10msec increments in DRM off p 0 or from 10 to 10000 in 10msec increments in DRM on Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail 73 E Response Format I Response code SP Tag count SP TIF information s 4 4 1 3 1 n Item Description 0000 Normal end For other Response codes refer to Hesponse Code Li
10. Locations not within the specified operating temperature range Reader Writer 10 to 50 C Antenna 15 to 60 C RF Tag 10 to 55 C Locations not within the specified operating humidity range 25 to 85 Locations exposed to any flammable gasses corrosive gasses dust metallic powder or salts Locations subject to direct vibration or shock outside the specified ranges Locations where the reader is exposed to direct sunlight Reader Writer Normal type Antennas Locations subject to spray of water oil or chemicals Reader Writer Normal type Antennas Locations subject to oil or chemicals Waterproof type Antennas Locations nearby high temperature devices such as heater transformer high wattage resistor Locations near by power line line for deliver large current such as motor cable If it needs to locate the reader proximitry to power line please conduct testing to reduce the influences of electric nois Outdoor Reader Writer Normal type Antennas m O A When two or more Reader Writers are set up the influence of the interference of the Reader Writer is tested enough beforehand and it confirms it 5 M communication between RF tag and the reader may vary according to the environment condition Please test prior to the operation ww CHECK 7 eFor the installation follow the instruction below and conduct enough testing
11. RS 232C parity bit 232C RS 232C parity bit bit N none Nimme O odd E even odd E even Eeen even 1 1 bit RS 232C stop bit 2 2 Stop bit 2 2 stop bit UHF RFID System User s Manual 101 SECTION 5 Command Line Interface Set Reader function SETHR This command writes the functional conditions of the command in process into the nonvolatile memory in the reader The setting shall be enabled at the upcoming startup Command Format Command code SP Parameter 1 SP SP Parameter s E r R 4 1 n 1 1 n Setting item Setting value Parameter 3 1 n Setting value is connected by the equal sign 2 and specified the set item Refer to the Function condition setting of Reader Writer for details of a set item 101 o m O T Response Format Response code u 4 4 Item Description 0000 Normal end For other Response codes refer to Hesponse Code List I p 71 puewwos Dunes Response code UHF RFID System 102 User s Manual SECTION 5 Command Line Interface Command Response Example Set Reader function SETR SETR S Param1 Value1 S S ParamN ValueN lt LF gt S Space code param Setting value is connected by equal sign and specified SETR RC LF RC Response Code Response Example 1 When DHCP Enabled is set ON Tx
12. Perma lock 0 1 Block Password Perma lock 0 1 Read Write Lock U3 Pass Pwd R W 0 1 0 1 0 1 Values are specified by Block Lock command Represents write lock status for each block with bit Bit Description 7 U5 Pass User Pwd write 0 1 8 Perma lock 0 1 9 U4 Pass User Pwd write 0 1 Perma lock 0 1 U3 Pass User Pwd write Perma lock 1 U2 Pass User Pwd write 0 Block Write Lock Perma lock 0 1 U1 Pass User Pwd write 0 1 Perma lock 0 1 10 spueuiuioo 2 Values are specified by Block Lock command Secure function is supported by certificication number at 001AHB1004 001 1002 The reader which certification number is 001AHB1001 can not use this function Also Secure function can only use for the RF tags which supports Secure RFID protocol The standard EPC global Class1 Generation 2 RF tags does not work UHF RFID System 98 User s Manual SECTION 5 Command Line Interface Set Attenuat SATT E Command Format Command code SP Level SP Lock SP Option 1 SP SP Option n S A Tii 4 1 1 1 1 1 n 1 1 n Description 0 Level 0 zero 1 6 RFU 7 Level 1 0 Level value is not controlled with lock 1 Level value is set unchangeable permanently Option code Available Optional Value Specifies orde
13. SECTION 4 Diagnosis and Maintenance Normal type Antennas V740 HS01CA V740 HS01LA Flat washer Mounting Hole Dimension 235 0 2 _ Eight M6 or Eight 6 5 dia too 8 d e gt y im r 4 A a N Unit mm VL Tighten the screw with the torque for moutning UHF RFID System User s Manual SECTION 4 Diagnosis and Maintenance Wiring for cable Connection with Host Device B Ethernet Interface The cable is inserted and connected with the Ethernet port connector of the Reader Writer When connecting it directly with PC Crossing Cable h Ly H 34 X X Y Y Y X x x aaa CC Ert rye ir tin n 1 Use sheiled Ethernet cable For the cable length use the cables which are available in the market UHF RFID System User s Manual 9 qeo 10 Ie TREE S SECTION 4 Diagnosis and Maintenance RS 232C Interface Connecting to the PC Serial setting is set for flow control Reader Writer D Sub 9 pin male inch screw RS 232C Pin number Signal name m O AB m e Connecting to the Omron s PLC
14. e Do not change cable length of antenna cable e The antenna connector TNC typpe and N type are not water proof CHECK In case there are possibility to drop of water at anntenas and antenna cables use water proof tape at the connector connection portion UHF RFID System User s Manual 27 suoneouir eds SECTION 2 Specifications and Performance Specifications General Specifications Reader Writer V750 BA50C04 US Power supply Reader Specification 12 VDC via attached AC Adapter Less than 28W voltage AC Adapter 100 to 240 VAC 50 60Hz 0 5 A at 120 V Power consumption Ambient operating temperature Ambient storage temperature Ambient storage temperature 28 W max 10 to 50 C with no icing 25 to 85 with no condensation 25 to 65 C with no icing Insulation resistance 20 MQ min at 100 VDC mega between connector terminals and case Dielectric strength 1 000 VAC 50 60 Hz for 1 min between connector terminals and case Dielectric strength 10 to 150 Hz 0 2 mm double amplitude acceleration 10 sweeps in each of 3 axis directions up down left right and forward backward for 8 minutes each Shock resistance 150 m s2 3 times each in 6 directions Total 18 times Dimensions 246 x 215 x 43 5 mm W x H x D Degree of protection IP50 IEC60529 Antenna Connections 4 channels Case material Mounting Tightening torque
15. e Antenna cables should not gather together with other cables and only specific antenna cable Model V740 A01 3M check 10 20 can be used e Power cables and I O cables should not gather together with other cables as much as possible e f the anntena and antenna cable expose to drops of water use water proof tape at the antenna connector e Do not remove the metal fittings attached with the water proof antennas It may cause the deteroration of performance of water proof UHF RFID System 52 User s Manual SECTION 4 Diagnosis and Maintenance Installation and Wiring Fix the reader and antennas rigidly by using its mounting hole which mounting schematics shown below Use M4 screws with spring washer and flat washer for mounting the reader Use M6 screws with spring washer and flat washer for mounting antennas Use M3 screws with spring washer and flat washer for mounting RF tag Do not use the organic solvent such as screw lock tight after tighten the screws It may cause the damage to the mouting panels Mounting Hole Dimensions B Reader Writer V750 BA50C04 US m O AB opring washer Flat washer 3 pue 5 Mounting Hole Dimensions 235 0 3 Four 4 or Four 4 5dia 152 4 0 3 t Q Tighten the screw with the torque 1 2Nem for moutning e CHECK UHF RFID System User s Manual 53 m O A pue 5 54
16. If you do not specified options the following condition will apply to each option as default setting tmo 250 ms tif No additional tag information pwd Access password is not used tc 1 C1G2 Notes Timeout settings Please choose the timout value when you use repeat command SRP MRP It may cause the reader system halt error depending on the Ehternet or RS 232C communiction status due to lots of packets exchange If Ethernet network which the reader connected is large or communnication settings of RS 232C is low it requires longer timeout value to avoid this error Required parameters and selectable options for each command for the Secure Tags Following table shows parameters to be set and selectable options for communication command operation Secure function is supported by certificication number at 001AHB1004 001PVAB1002 The reader which certification number is 001AHB1001 can not use this function Also Secure function can only use for the RF tags which supports secure RFID protocol The standard EPC global Class1 Generation 2 HF tags does not work Command Data Options Parameters mandatory Command Code tmo Lock Read LKRD Lock code Write Multiple Words WTMW Memory bank data pointer and data to be written Lock Block LKBK Block number user password and lock code Lock Read Block LKRB Block number user password and lock code ead System Information RDSI Non Set Attenuate SATT
17. RC Response Code S Space code param Setting item is specified by the sign value Setting value is connected by equal sign and specified Note If the setting value includes any space the space shall be enclosed with double quotation Example 1 When executed command is read at startup Tx tec lt LF gt Rx GETOO000 1 RDID ant 122322 tmo 100 lt LF gt Example 2 When Input 2 function setting is never registered Tx GETO in2 lt LF gt Rx GETOOO000 2 0 O LF o m O T Example 3 When Input 1 function setting is read Tx GETO in1 lt LF gt Rx GETOO000 1 1 0 RDID ant 122322 tmo 100 lt LF gt Example 4 When Input 3 function setting is read but the setting is not alive Tx GETO in3 lt LF gt Rx GETOOO000 in3 0 0 RDID seq MOC ant 123 lt LF gt pueuiuio Dunes Example 5 When Output 4 function setting is never registered Tx GETO ot4 lt LF gt Rx GETOO000 ot4 00 O LF Example 6 When Output 1 function setting is read Tx GETO ot1 lt LF gt Rx GETOOO000 ot1 31 2000 DAT 0000 gt Example 7 When Output 2 function setting is read and the setting is not alive Tx GETO ot2 lt LF gt Rx GETOOO000 ot2 00 2000 DAT 0000 lt 1 gt UHF RFID System 112 User s Manual SECTION 5 Command Line Interface Communication Settings To set the conditions to communicate with tags following items shall be sp
18. UHF RFID System V750 Series User s Manual V750 BA50C04 US Mono static Reader Writer V740 HS01CA Circular Antenna V740 HS01LA Linear Antenna Introduction Thank you for purchasing an ID Sensor Unit for a V750 series RFID System This manual describes the functions performance and application methods needed for optimum use of your V750 series RFID System Please observe the following items when using the V750 series RFID System Allow the V750 series RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems Read and understand this manual before attempting to use the V750 series RFID System and use the V750 series RFID System correctly Keep this manual in a safe and accessible location so that it is available for reference when required READ AND UNDERSTAND THIS DOCUMENT pem c O 611 Features and System Configuration L NOILOAS Sree 2 Specifications and Performance 0 Mode and Function 5990 Diagnosis and Maintenance Command Line Interface Browser Based Interface Section 6 Troubleshooting Alarms and Errors 2 Reference data Appendices 2 OS Bom RENE Irae Fe R
19. 1 2 3 4 DG G Operation Status Indicator The power indicator does not lit PWR RUN ERR NORM ERC OOOO ANTENNA 1 2 3 4 O OO RUN indicator does not lits or ERR indicator lits PWR RUN ERR ooo ANTENNA 2 3 4 O O O PWR RUN ERR NORM ERC 1 2 3 4 OO OO ERR indicator blinking fast blinking PWR RUN ERR NORM ER ERC O O O ANTENNA p 2 3 4 SO X UHF RFID System User s Manual Potential cause AC adapter does not connect correctly On the communication state when getting the command and execute the communication with RF tag PWR RUN ERR NORM ERC e eoe ANTENNA i 2 3 4 e 00 The antenna indicator lits on which the reader receive the command Countermeasure Check the connection at the DC line Check the connection at the AC100V line Failure of AC adapter Failure of the reader Failure of the reader The setting error on the reader Check the DC12V output at the DC plug of AC adpater by using Voltage tester Note Do not execute this confirmation process if you are not electrical specialist to allow this operation Please ask your sales representative of Omron Please ask your sales represenative of Omron Execute power on reset If the reader still indicates same after power on reset please ask your sales representativ of Omron The settings on the reader does not set up
20. Init All Settings To initialize all the settings of the reader press Init All Settings button After displaying message Accepted INIT Reboot in one second all the reader s settings are initialized to factory installed settings After initializing the reader you can access the browser by clicking Reload button or opening another browser Errors 1 Can Not Connect lt means that the host computer can not receive the data from the reader In this case you have to check the Ethernet connection restart the browser and then access the reader again UHF RFID System 146 User s Manual SECTION 7 Troubleshooting Alarms and Errors Errors and Countermeasures 148 Maintenance and Inspection 151 4 Troubleshooting 152 Z NOILO3S UHF RFID System User s Manual 147 9 5 10119 FANCIES 148 SECTION 7 Troubleshooting Alarms and Errors Errors and Countermeasures The reader shows various indication or message when the error occurs to inform the reader error status correctly The errors are distinguished as follows B Error on reader The operation status indicator on top of the reader shows the error of the reader itsself if it s happened The following figure shows lit condition for normal operation and if error occurs the indicator shows differently the ready state which wait to receiving the command from host system PWR RUN ERR NORM ERC e 6 o0 ANTENNA
21. Stop Bit Length Parity Even Odd None Is not the noise generated near the communications cable For RS 232C Is FCS correct Calculation format Binary 2byte For RS 232C e s the command format correct Communications Designations Data specification Type of tag Page Write data e s not another executed Command Excluding STOP and REST etc transmitted while executing the command 5 not the command of the condition that cannot be executed transmitted 18 e Does not Data Length of the command more than 512 bytes e Do not two or more Reader Writere communicate e Has not the channel setting used been reduced e Isn t the password wrong in the command that should specify the password e Does tag exist in steady communication area e Is not the page of tag outside the memory range specified s it tag supported by Reader Writer e Is the distance between tag and the antenna a distance in which it can communicate e Does not tag move while processing the communication e Does not two or more tag exist in communication area e Does not the writing frequency of tag exceed memory lonevity e Is not the written page locked 5 it tag supported by Reader Writer Is the memory specification of tag memory bank address etc correct e Is the distance between tag and the antenna a distance in which it can communicate e Does not
22. in case of data length is 7bits Program the communication control to consider that FCS may contain the control charactor such as SOH or CR Depending on the programming tool or coding method some of character code can not be used Please check the programming tool before progrmmaing UHF RFID System User s Manual U m O T ewo esuodseg pueuiuio 75 SECTION 5 Command Line Interface Communication Command Read ID RDID E Command Format Command code SP Option 1 SP SP Option n R D D 4 1 n 1 1 n Option code Available Optional Value SOC Single Once SRP Single Repeat MOC Multi Once MRP Multi Repeat Number of antenna Specifies order of antenna operation with figure 1 4 max 9 characters Communication sequence Process time out msec 0 or from 100 to 5 000 in 10msec increments Additional information responded with data ANT antenna number CNT count of read tags Additional tag information ecce pede j PER PC bits EPC code and CRC LVL Receiving level of signals sent from the tags Refer to the Option Details in detail 3 1 73 protocol 1 Q S O E Response Format 5 ID and _ ID and D Command code Response code SP Tag count SP TIF information SP SP TIF information Item Description 0000 Normal end For other Response codes refer to
23. 1 200 2 IMSOCOA US Wi ew Internet Explorer Eje io B ug ipi AR ever pot phew Dita Ge Agade Comm Srtings Oppratan Gomm Tess akt Reader Status When other menus are displayed it clicks Product Type VIS0 BAS0COA LIS Firmware Version 101 101 102 0 Serial Number nogogog MAC Address 00 00 0A 89 03 5E Valid Antenna s 1234 Operation Status Ready TEPIP Connection Hn Connection VIAN Operation Warning 3 Latest Comm Source Command The web operation might affect the control Result from command line interface 5 2320 Operation Time 00 00 57 Appii Barekppiet started OK Because the command can operated from two or more menu panels the case of a command execution not acceptable is displayed as a warning It is possible to shift only for OK o2eJ19 u poseg 19SMO1g RFID System 130 User s Manual Option Mode Status Product Type Firmware Version Serial Number MAC Address Valid Antenna s Options Operation Status TCP IP Connection Comm Settings Operation Settings Reader Status V750 BA50C04 US 103 103 104 0 0000000 00 00 0A 89 03 01 1234 1 Ready No Connection SECTION 6 Browser Based Interface Firmware Update Comm Test Utility Reset System When the system is reset It clicks Latest Comm Source Command Result Oper
24. 2 Condition 2 Output 2 Output 3 Duration for output 0 or more and less than 9990 Condition for output Available only when function is NML or ERC Programmable output 2 settings Setting items are the same as Output 1 Programmable output 3 settings Setting items are the same as Output 1 Output 4 2 Programmable output 4 settings Setting items are the same as Output 1 The programmble output OUT1 to OUT4 can be enabled to input by checking the box 9 It requires the setting when the NRL or ERC is selected as trigger The settings are effective to store the inputted condition in the internal memory by clicking Store button and after re booting Storing process take effect in the order from top of the list and turns on blue if the item correctly stored If the error occurs it turns on red and the process is terminated epoy uondo UHF RFID System User s Manual 137 epojiy uondo 138 SECTION 6 Browser Based Interface Communication Test RO Firmware Update Status Reader Settings Comm Settings Operation Settings Comm Test Utility Communication Test Click to stop the execution of repeat command Command Sequence Antenna ID Time Out ES RDID seq MOC ant 1 tmo 250 tif EPC Click to send the command Click to clear the response indicator area 1 Option List Description Command RDID WTID Default Sequence SOC
25. 4 ports V740 HS01CA or V740 HS01LA Control method V750 original command response Control port Ethernet Supported standard IEEE802 3 compliance 10Base T IEEE802 3u compliance 100Base TX Supported protocol TCP IP Port 7090 Changeable RS 232C Supported standard RS 232C compliance Baud rate 9 6 19 2 38 4 57 6 kbps Data length 7 8 bits Parity Even Odd None Stop bit 1 2 bit suoneouyiooeds FAN e IRE S Browser interface Ethernet Protocol HTTP Port 80 Fixed TCP IP Port 7091 Changeable Digital Input Output 4 Inputs 4 Outputs Status indicator 8 Operation status POWER RUN ERR NORM ERC ANTENNA 1 4 4 Inputstatus 4 Output status Self diagnostic function 1 CPU operation check 1 2 Antenna connecting check 3 Communication error detection with tags 1 2 Software upgradable Antenna control port Scalability E Antennas V740 HS01CA HSO1LA Specification Item V740 HS01CA V740 HSO1LA Polarization Circular Linear Operating frequency 902 928 MHz Imedane Mew a lt 9 _ 5 1 Maximum Input Electric power 1W B Antenna Cables V740 A01 3M 10M 20M It Specification em V740 A01 3M V740 A01 10M V740 A01 20M Insertion Loss in 3 0 dB min Cable Type 3D 2V Note Cable Loss for V740 A01 20M cable is about 3 0dB and communication range was reduced about 80 compare to the 3m and 10m cables UHF RFID
26. Communication condition Settings OMRON Reader Settings Status RF Control Antenna Power Session Mode EPC word len Filtering Filter Selection Filter1 Filter2 ing 9 Omit Response 1 RF Control Antenna Power to 4 epojiy uondo Session Mode EPC word len Power dBm of each antenna from 1 Session number of Gen2 protocol set for Multi sequence and Single sequence respectively Communication mode EPC word length Firmware Update Click to enabled the i Utility Communication Settings ANT3 81 5 ANTA 31 5 SRPIMRPI2 C DRM 1 81 5 2 81 5 SOCIMOCIO Normal Click to save the settings after operation 2 Bank CQ 1 Pointer 8 Data 205 01 Length bit 32 e 3 Length bit 84 Bank C0 C1 Pointer 0 Smoothing Buffer 100 Disable Enable The range of the set code 10 0 to 32 0 Truncate by 0 5 Ex 10 3 is truncated to 10 0 and 10 8 is truncated to 10 5 0 1 2 3 Description Normal DRM 0 to 32 Step 1 Default Every antenna 31 5 SOC MCC 0 SHP MRP 2 The range of antenna output power is different on each the reader which has different certification number The certfication number is shown on product label attached the reader UHF RFID System User s Manual 134 2 Filtering Item Condition Selection
27. Description Determines filtering condition SECTION 6 Browser Based Interface The range of the set code Default Condition 1 Set value of the Condition 1 Bank Pointer Communication data bit length Comparison start point None 1 2 1 and 2 None 1or2 0 to 3 None including threshold values 0 to 255 including threshold values Length Data Comparison bit length Comparison data 1 to 255 including threshold values None None Data length more than 1 or more and 64 or less Condition 2 Set value of the Condition 2 Bank Communication data bit length 0 to 3 including threshold values Pointer Comparison start point 0 to 255 including threshold values Length Data 1 Only selectable items are selectable as input condition 2 The comparsion condition can specified by bit unit in the data length while the comparison data need to be specified by byte unit Set the byte above bit unit as the comparison data For example if you want to set the comarsion condition as 1 in 3 bits set the 70 as the comparsion data 3 Smoothing Item Smoothing Buffer Comparison bit length Comparison data Description Prevents rereading 1 to 255 including threshold values Hex string whose length is 1 more None and 64 or less epoy uondo The range of the set code Default to 999 includ
28. Description opecifies memory address of the targeted area in the user memory 1 5 Specifies a password for each user area User password The password should be same as the password set previously in the password area corresponding to the block number set above Block number opecifies a lock type of an password memory area intended to be controlled with double digits code shown as below 3 4 U Pass User pwd perma write lock Lock Code Type of lock m O T Cancels temporal lock Unlocks permanently Locks temporally It can be unlocked Locks permanently It cannot be unlocked Option code Available Optional Value Specifies order of antenna operation with figure 1 4 max 9 characters The figure 1 to 4 is antenna s identical number Number of antenna 0 or from 10 to 2550 in 10msec increments in DRM off p Ume USER 0 or from 10 to 10000 in 10msec increments in DRM on Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail 73 Specifies a password with 8 digit hex number 32 bit word Access password It is essential unless the value in the area of tag Access Password is zero 10 spueuiuioo 2
29. Hesponse Code List 71 count Count of read tag s Response code ID read from tag and Tif information specified with command Each optional value for tif information lines with comma separation ID and TIF information UHF RFID System 76 User s Manual SECTION 5 Command Line Interface Command Response Example Read ID RDID RDID S options lt LF gt S Space code options When it is necessary the option is specified RDID RC S CNT S ID1 with ITM1 S IDn with ITMn lt LF gt S Space code RC Response Code CNT Tag Count IDn with ITMn with Items indicated by TIF option Items are delimited by a comma Note If EPC data length is 0 zero the ID shall be Example 1 When command is processed with all options omitted and the R W reads a single tag Each option item is specified with default values Tx RDID lt LF gt Rx RDIDOO00 001 1234567890ABCDEF 12345678 lt LF gt Without any options the command is executed with seq SOC ant 1 tmo 250 and EPC data 1234567890ABCDEF 12345678 is returned Example 2 When SingleOnce Antenna 1 and 2 is specified the command is executed and when the R W reads two tags Tx RDID seq MOC ant 12 lt LF gt Rx RDIDOOOO 002 111111111111111111111111 222222222222222222222222 LF o m O Example When MultiRepeat Antenna 1 4 read items PC EPC CRC Antenna Read co
30. Input reads ON OFF state by receiving the command from the host 2 Command entry executes registered command series at the rising edge of input signal Digital output Programmable output Following three functions can be assigned to 4 digital outputs respectively To assign the function set Communication results output outputs ON OFF signal depending on the specified judgment after communication process m via Set Operation window of command or Web 1 User output outputs ON OFF state according to the command from the host EY 2 Reader state output outputs operation status of the reader 5 xi gt Refer to the Self Operation for details pe 42 UHF RFID System 40 User s Manual SECTION 3 Mode and Function Reader control function The function of control the reader device provides the interpretation of the command from the system 1 F to tag communication control and vice versa Command Execution Receiving a command from the host via Ethernet or RS 232C the reader starts the command execution and return its response result to the host You can use following commands Refer to the Command Line Interface for details CHECK I p 99 e Communication command The command is used to communicate with RF tag In the commmunication command you can specified the communication parameter for single access mode which communicates with just sin
31. Level and lock information Write Pass Word WTPW Block number and user password A Only SOC can be specified Only 1 Gen2 can be specified o m O T esuodseg pueuiuio If you do not specified options the following condition will apply to each option as default setting Default 5 SOC ant 1 tmo 250 ms No additional tag information pwd Access password is not used ptc UHF RFID System 74 User s Manual SECTION 5 Command Line Interface Example FCS calculation for RS 232C FCS is the result of the horizontal parity calculation Exclusive OR of the data right after SOH to the end of the Command data Command RFID seq MOC ant 1 tmo 500 Command code Command data SOH 01 52 44 49 44 20 2D 73 65 71 19 is translated to 31 and 39 as ASCII code Character ASCII Code Hex 0101 0010 0100 0100 0100 1001 0100 0100 R 52 D 44 49 D 44 20 2D S 73 e 65 q 71 M 4D O 4F Space 0010 0000 C 43 20 0110 0001 2D t 74 0010 1101 0111 0100 0110 1101 0110 1111 0010 0000 5 35 0011 0101 1 SVA Note Programming for communication control This FCS represents the calculation result of horizontal parity with data and terminater strings Therefore The FCS SUE includes all the code from to FFh 00h to 7Fh
32. Manual 49 SECTION 4 Diagnosis and Maintenance Connection of Reader and each equipment The reader needs to be connected to antennas and host controller such as PC and PLC to operate as system Also when it operates by external Input Output devices it needs to be wiring to those device to enable exchange control signals This chapter decribes how to connect for those external devices Photoelectric sensor I O Device Host Device Lamp Buzzer PC Personal computer PLC The Signal wire of external input output devise is connected Antenna Option V750 Reader Writer AC Adaptor Accessory HH The Antenna or the Antenna Cable Antenna Cable Option 3m Antenna Cable Option 10m pue jo uonoeuuo2 FAN eel B Confirmed item Please confirm the following items before supplying the AC power supply of the AC adaptor Confirmed item Confirmed content Make sure the connection between antenna cable and antenna and also antenna cable and the reader antenna port Connection of Signal wire of external Make sure wiring from the external devices to the terminal at the reader are input output device securly tighten Conection of DC Jack of AC adaptor Make sure the DC jack connected to AC adapter securely Pleaese check all accessories
33. SECTION 2 Specifications and Performance PWR RUN ERR NORM Indicator Green ON Green ON Power RUN Running Color Status Meaning Normally energized Normally running Flashing Short interval Boot processing Flashing Long interval Safe Mode running Reader error ON RUN indicator off System error The error has occurred and it stopped the system operation ex System error Unrecoverable error Flashing RUN indicator on Short Interval Recoverable error Flashing Long interval Setting error The error has occurred and it stopped by settings ex Power shut down in command communication ex Communication setting error ex Disconnection to the DHCP server Waiting for network connection Communication result ON Normal end Command executed or communication with tag completed normally Turns off after 50ms ON or upon ERR LED turns on Communication result Error of Communication Command executed or communication with tag completed abnormally Turn off after 50ms ON or upon NORM LED turns Antenna port 1 Communication process is running via antenna 1 When connecting with an antenna via antenna 1 is detected after power turns on it lights for 50ms Antenna port 2 Communication process is running via antenna 2 When connecting with an antenna via antenna 2 is detected after power turns on i
34. SP TIF information 4 4 1 3 1 n 1 1 n Item Description Response code Tag count TIF information 0000 Normal end For other Response codes refer to Hesponse Code List US p 71 Count of locked tag s Tif information specified with command Each optional value for tif information lines with comma separation UHF RFID System User s Manual U m O T pueululo uoreoiunululo2 85 o m O T 86 SECTION 5 Command Line Interface Command Response Example Lock LOCK LOCK S LockCode S options L gt S Space code LockCode Lock Code 10 characters 0 1 options When it is necessary the option is specified LOCK RC S CNT S ITM 1 S ITM n lt LF gt S Space code RC Response Code CNT Tag Count ITM n Items indicated by TIF option Items are delimited by a comma Example 1 When EPC memory locked temporarily is set Tx LOCK 10 lt LF gt Rx LOCK0000 001 lt LF gt Example 2 When Access password and Kill password locked temporarily is set with password OxABCDABCD Tx LOCK 1010 owd ABCDABCD LF Rx LOCK0000 001 lt LF gt Example 3 When Access password and Kill password unlocked is set with password OxAAAAAAAA tag information EPC code and antenna Tx LOCK 0000 owd AAAAAAAA tif EPC ANT lt LF gt Rx LOCK0000 001 77777777
35. Secure function can only use for the RF tags which supports BEC secure RFID protocol The standard EPC global Class1 Generation 2 RF tags does not work o m O T 10 spueuiuioo 2 UHF RFID System 90 User s Manual SECTION 5 Command Line Interface Write Multiple Words WTMW E Command Format Command code SP Memory Bank SP Data Pointer SP Written data SP Option 1 SP SP Option n Ww 4 1 1 1 1to3 1 1 to 3 x4 1 n 1 1 n Description Specifies memory bank of Gen2 tag 0 Reserved Area Memory bank 1 EPC Area 2 TID Area 3 User Area Specifies memory address intended to access in the memory bank in word 16 bits increments Data pointer 0 255 Written data Specifies hexadecimal number in word 16 bits increments maximum 32 words Option code Available Optional Value Communication sequence SOC Single Once Specifies order of antenna operation with figure 1 4 max 9 characters Number of antenna The figure 1 to 4 is antenna s identical number U m O T 0 or from 10 to 2550 in 10msec increments in DRM off Process time out msec 0 or from 10 to 10000 in 10msec increments in DRM on Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC b
36. Setting item Setting value Parameter 3 1 n Setting value is connected by the equal sign 2 and specified the set item Refer to the Function condition setting of Reader Writer for details of a set item I p 101 o m O Response Format Response code pueuiuio Dunes s e t c 4 4 Item Description 0000 Normal end For other Response codes refer to Hesponse Code List 71 Response code UHF RFID System 114 User s Manual SECTION 5 Command Line Interface Command Response Example Set Communication SETC SETR S Param1 Valuet S S ParamN ValueN LF S Space code param Setting value is connected by equal sign 2 and specified value Setting value is connected by equal sign 2 and specified Note e It specifies a parameter connecting a setting item to a setting value setting item does have to be prepended with No space shall be put in from the beginning of the setting item to the end of the setting value Command unless setting item is ft1 or ft2 elf you specify ft1 and ft2 for filtering set ft1 ft2 and fte at one sequent action ft1 and ft2 shall be always followed by Filtering Enable fte If you specify them in one command firstly put 1 and ft2 then fte in order If you change the filtering conditions with ft1 and or ft2 the filtering function will be te
37. Stop Bit s C 1 2 1 Reader Information Item Reader Name Reader Role 2 Ethernet Item Host Name Domain Name Description Reader name defined by its user The role of the reader defined by its user Description Name to refer the host in the network Domain name in the network environment for the reader 38400 Click to enabled the settings f 57600 The range of the set code Represented with from 1 to 63 ASCII characters Represented with from 1 to 63 ASCII characters The range of the set code Represented with from 1 to 63 ASCII characters Represented with from 1 to 67 ASCII characters Default Default V750 BA50C04 US None DHCP Whether the reader uses DHCP serve or not Disabled Enabled Disabled IP Address IP address of the reader 192 168 1 200 Subnet Mask The reader s subnet mask address 255 255 255 0 Gateway The reader s Gateway address 192 168 1 254 TCP IP Port 3 RS 232C Baud Rate bps Port number of command interface Description Communication speed 1025 to 65534 The range of the set code 9600 19200 38400 57600 7090 Default 5 600 Data Bits Communication data length 7 8 7 Parity Bit Stop Bit s Parity bit Stop bit Even Odd None Even UHF RFID System User s Manual epojyy uondo 133 SECTION 6 Browser Based Interface
38. command execution is set RS 232C Tx SETO rif 2 lt LF gt Rx SETOO000 LF Example 2 When the executed command at the start up is set as RDID ant 122322 tmo 100 Tx SETO 1 RDID ant 122322 tmo 100 lt LF gt Rx SETOO000 LF Example 3 When Input 1 function setting is set as Command execution start up edge RDID ant 122322 c tmo 100 3 Tx SETO in1 1 0 RDID ant 122322 tmo 100 lt LF gt 2 Rx SETOOO00 lt LF gt Example 4 When output 3 function setting is set as Signal is on for 2 seconds when the executed command is finished normally the read data is 12bytes 24characters and the 5th to 8th e data is 0000 5 Tx SETO ot3 31 2000 dat O000 lt l F gt Rx SETOOO00 lt LF gt Example 5 When output 4 function setting is set as Signal is on for 1 second if tag count is 10 or less Tx SETO ot4 31 1000 TC T lt 10 lt LF gt Rx SETOOO00 lt LF gt Example 6 When output 2 function setting is set as Signal is on for 1 second if both conditions on example 5 and 6 are fulfilled Tx SETO ot2 31 1000 DAT 0000 8 TCT lt 10 lt LF gt Rx SETOOO00 lt LF gt Example 7 When output 2 function setting is set Signal keep on when ERC Communication error Tx SETO ot2232 O LF Rx SETOO000 LF Example 8 When output 2 function setting is set as Signal is on for 2 seconds if any code error of 71xx 72xx or is oc
39. has been sent A sequence when the reader detects tags one by one as it repeats the transaction Just after the reader communicates a tag it returns a response reporting the read tag data to the host Timeout Timeout Timeout gt NEN Response ZEN Response Response Read Process Read Process Read Process Command SRP Host Device Reader Writer RF Tag A sequence when the reader carries out the transaction repeatedly and there is no tag At the end of the specified period the reader returns a response reporting no tag to the host Command SRP o m O T Timeout Timeout gt NEN Response S Response Host Device Reader Writer RF Tag oouenbes UHF RFID System 62 User s Manual SECTION 5 Command Line Interface Multi Access Mode In this mode communications with all RF Tags in the communications area can be made on receipt of the command N a B Multi Once The reader reads multiple tags for a specified period At the end of the specified period it returns read results and finishes the transaction If the reader does not detect any tag during the specified period it returns a response meaning there is no tag A sequence when the reader detects tags for the specified period At the end of the specified period the reader returns a response reporting the read tags data to the host Comm
40. in the password area corresponding to the block number set above Block number Specifies a lock type of an password memory area intended to be controlled with double digits code shown as below 1 2 pwd perma read lock Lock Code Type of lock m O T Cancels temporal lock Unlocks permanently Locks temporally It can be unlocked Locks permanently It cannot be unlocked Option code Available Optional Value Specifies order of antenna operation with figure 1 4 max 9 characters The figure 1 to 4 is antenna s identical number Number of antenna 0 or from 10 to 2550 in 10msec increments in DRM off p Ume USER 0 or from 10 to 10000 in 10msec increments in DRM on Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail 73 Specifies a password with 8 digit hex number 32 bit word Access password It is essential unless the value in the area of tag Access Password is zero 10 spueuiuioo 2 Tag protocol 1 Gen2 UHF RFID System 94 User s Manual SECTION 5 Command Line Interface E Response Format Response code SP Tag count SP TIF
41. information E T 4 4 1 3 1 n Item Description 0000 Normal end For other Response codes refer to Hesponse Code List 71 Response code Tag count Count of locked tag s Tif information specified with command TIF information m TE Each optional value for tif information lines with comma separation M Secure function is supported by certificication number at 001AHB1004 001PVAB1002 The reader which certification number is 001AHB1001 can not use this function Also Secure function can only use for the RF tags which supports ww secure RFID protocol The standard EPC global Class1 Generation 2 RF tags does not work U m O T eounoes 10 aAIsn ox3 UHF RFID System User s Manual 95 SECTION 5 Command Line Interface Read System Information RDSI E Command Format Command code SP Option 1 SP SP Option n Option code Available Optional Value Communication sequence SOC Single Once Specifies order of antenna operation with figure 1 4 max 9 characters The figure 1 to 4 is antenna s identical number Number of antenna 0 or from 10 to 2550 in 10msec increments in DRM off Process time out msec 4 or from 10 to 10000 in 10msec increments in DRM on Additional information responded with data ANT antenna number CNT count of read
42. malfunctions may however result due to the operating environment and conditions 1 Element deterioration due to overvoltage or overcurrent 2 Element deterioration due to continuous stress caused by high ambient temperature 3 Connector contact faults or insulation deterioration due to humidity and dust 4 Connector contact faults or element corrosion due to corrosive gas Detai ate equipment Supply voltage Check that the supply voltage fluctuation at the Within supply voltage Multimeter fluctuation power supply terminal block is within the specified range permissible range B inspection Items Check that there are no frequent Within permissible voltage Power supply instantaneous power failures or radical voltage flucuation range analyzer fluctuations Ambient environment Maximum and 1 Temperature 1 Within the specified range 1 Within the specified range minimum 2 Humidity 2 Within the specified range 2 Within the specified range thermometer 3 Vibration and shock 3 Influence of vibration or impact of machines 3 Within the specified range Hygrometer 4 Dust 4 Check that the system is free of 4 Neither is permitted accumulated dust and foreign particles 5 Corrosive gas 5 Check that no metal part of the system is 5 Neither is permitted discolored or corroded I O power supply Check on the I O terminal block that the Within the specified range Multimeter 1 Voltage fluctuation voltage fluctu
43. materials is provided as a guide for the user in determining suitabil ity and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application require ments Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our prac tice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifica tions of the Product may be changed without any notice When in doubt spe cial part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions OMRON AUTOMATION amp SAFETY OMRON AUTOMATION AND SAFETY THE AMERICAS HEADQUARTERS Chicago IL USA 847 843 7900 800 556 6766 www omron247 com OMRON CANADA INC HEAD OFFICE OMRON ARGENTINA SALES OFFICE Toronto ON Canada 416 286 6465 866 986 6766 www omron247 com Cono Sur 54 11 4783 530
44. monitor screen the progress bar is shown When the firmware upgrade is complete all the indicator Antenna IN OUT turn on and message comes up on the monitor screen If the firmware upgrade are completed successfully the reader will re boot after 3 sec A Do not power off during firmware upgrade ww CHECK UHF RFID System 144 User s Manual SECTION 6 Browser Based Interface Safe Mode Safe Mode is used for confirming the essential reader settings You can obtain the setting information even though the reader has trouble in operation mode for example you can not access with Ethernet because of system error or your losing Ethernet IP address information On safe mode only status page and firmware update page are available Status Page Function Shows the information of reader status Ethernet and RS 232C settings Item value is displayed as operation mode Except Firmware Version Screen Image Click to update the firmware OMRON Safe Mode Reset System Click to reset the system Init All Settings U Reader Status Product Type 760 BA50C04 US Firmware Version 101 101 102 0 o Hered 9 serial Number 00000000 Address 00 00 20 4 89 03 00 m Ethernet Settings Operation Mode Host Name 750 BA50C04 US Domain Name OFF IP Address 192 168 1 200 Subnet Mask 255255 255 0 Gateway 192 168 1 254 TCP IP Port 7090 RS 2327C Settings Ope
45. programmable logic controller Serial setting is set for flow control none 9 qeo Reader Writer D Sub 9 pin male inch screw Sheiled cable should be grounded at host system side Cable length should be below 15m ww CHECK UHF RFID System 56 User s Manual SECTION 4 Diagnosis and Maintenance Method of assembling Terminal stand plug for external I O As an input output port the reader contains a terminal block of which connector is removable with SCrews Terminal block connector MC 1 5 10 STF 3 81 produced by PHOENIX CONTACT How to wire a terminal block connector with signal cables s and how to connect it to the reader body 1 Wire a signal cable s to the terminal block connector 9 to 10mm 2 Loosen the cable fixing screw s anticlockwise and insert the signal cable s all the way into the connector Tighten the cable fixing screw s clockwise m O AB 9 qeo 10J 3 Mount the terminal block connector to the reader body Fasten the terminal block connector with 2 mounting screws Required Tool Slotted driver Make sure to connect the signal cable to the terminal block connector prior to mounting the connector to the body LJ e Check the connection of the cables correctly match each other gt CHECK UHF RFID System User s Manual 57 m O 9 qeo 10
46. systems railroad systems aviation systems medical equipment amusement machines vehicles safety equipment and installations subject to separate industry or government regulations Systems machines and equipment that could present a risk to life or property Please know and observe all prohibitions of use applicable to the products NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM UHF RFID System User s Manual Introduction PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty It may represent the result of OMRON s test conditions and the users must correlate it to actual application requirements Actual performance is subject to the OMRON Warranty and Limitations of Liability CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons It is our practice to change model numbers when published ratings or features are changed or when significant construction changes are made However some specifications of the product may be changed without any notice When in doubt special model numbers may be assigned to fix or est
47. to 5 000 in 10msec increments Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code U m O T Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC 3 Refer to the Option Details in detail 5 gQ Tag protocol o 5 B Response Format 3 rT oT TT Td D Command code Response code SP Tag count SP TIF information SP SP TIF information Item Description 0000 Normal end For other Response codes refer to Hesponse Code List I p 71 Response code Tag count Count of killed tag s Tif information specified with command TIF information d Each optional value for tif information lines with comma separation UHF RFID System User s Manual 87 SECTION 5 Command Line Interface Command Response Example Kill KILL KILL S options lt LF gt S Space code options When it is necessary the option is specified KILL RC S CNT S ITM n S ITM n LF S Space code RC Response Code CNT Tag Count ITMn Items indicated by TIF option Items are delimited by a comma Example 1 When Password 0x22222222 is specified and then KILL command is completed normally Tx KILL pwd 22222222 lt LF gt Rx KILLOOO00 001 lt LF gt Example 2 When Password OxAAAABBBB Antenna 3 Tag information PER and ANT is specified and KIL
48. 0 OMRON ELECTRONICS DE MEXICO HEAD OFFICE M xico DF 52 55 59 01 43 00 01 800 226 6766 mela omron com OMRON ELECTRONICS DE MEXICO SALES OFFICE OMRON CHILE SALES OFFICE Santiago 56 9 9917 3920 OTHER OMRON LATIN AMERICA SALES Apodaca N L 52 81 11 56 99 20 01 800 226 6766 mela omron com 54 11 4783 5300 OMRON ELETR NICA DO BRASIL LTDA HEAD OFFICE Sao Paulo SP Brasil 55 11 2101 6300 www omron com br OMRON EUROPE B V Wegalaan 67 69 NL 2132 JD Hoofddorp The Netherlands 31 0 23 568 13 00 www industrial omron eu Authorized Distributor Automation Control Systems Machine Automation Controllers MAC Programmable Controllers PLC Operator interfaces HMI Distributed I O Software Drives amp Motion Controls Servo amp AC Drives Motion Controllers amp Encoders Temperature amp Process Controllers Single and Multi loop Controllers Sensors amp Vision Proximity Sensors Photoelectric Sensors Fiber Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision Sensors Industrial Components RFID Code Readers Relays Pushbuttons amp Indicators e Limit and Basic Switches Timers Counters Metering Devices e Power Supplies Safety Laser Scanners Safety Mats Edges and Bumpers Programmable Safety Controllers Light Curtains Safety Relays Safe
49. 000 Normal end For other Response codes refer to Hesponse Code List I p 71 The reader writer s operation is shown Reader Status 00 Stand by state 10 Communication processing 3X Setting value error 4X System error 90 Safe mode Response code Test Data The test data that turns is set 5 5 Command Response Example Test System TEST TEST S TestData lt LF gt TestData Given string TEST RC S ReaderStatus S TestData LF RC Response Code ReaderStatus Reader s status code 00 Waiting for command Response 10 Communicating 3x Setting error 4x System error 90 Running on Safe Mode TestData Same data as command parameter Command Example 1 When test data uhf rfid is entered to check a communication status between the host and the reader Tx TEST uhf rfid lt LF gt Rx TESTOOO00 00 lt LF gt Example 2 The reader s status check Tx TEST lt LF gt Rx TESTOO00 00 lt LF gt UHF RFID System 126 User s Manual SECTION 5 Command Line Interface Noise monitoring NOIS This command is to check the noise level of the specified antenna E Command Format Command code SP 1 SP 2 S 4 1 1 1 1 1 Noise level measurement Noise level measurement mode mode 0 fixed 2 Antenna port number The number of the antenna port where the noise level measurement is set E Response Format d
50. 16 SeeNote 2 OFh Bank 00 ACCESS Password 15 0 3Fh Password ACCESS Password 31 16 2Fh amp KILL Password 15 0 Reserved Area KILL Password 31 16 Note 1 PC 4 EPC length 16 x n1 Note 2 CRC16 calculated and stored at the time the tag chip memory powering up with the data of PC EPC only specified length value We Please check before operation when using the other manufacurere tag which comply with EPC global Class1 Generation2 ISO IEC18000 6 Also please refer the memory map specification provided from the IC chip CHECK manufacturer UHF RFID System 32 User s Manual SECTION 2 Specifications and Performance Memory Map of the Gen2 Tag For Impinj Co MONZA chip Following table shows the memory map of the Gen2 tag For Impinj Co MONZA chip Memory Bank2 Bank 10 Memory Bank1 Bank 01 EPC Area 128bit Memory Password amp Bank 00 Reserved Area 80bit Note 1 40h to AFh MSB 10h Tag Identification Memory Read only 00h Tag Identification Memory Read only LSB 1Fh OFh 70h EPC 15 0 7Fh 60h EPC 81 16 6Fh 50h EPC 47 32 5Fh 30h EPC 79 64 3Fh 40h EPC 63 48 4Fh 20h EPC 95 80 2Fh 1Fh 10h PC Protocol Control 00h CRC 16 OFh 40h See Note 1 4Fh 30h ACCESS Password 15 0 3Fh 20h ACCESS Password 31 16 2Fh 10h KILL Password 15 0 1Fh 00h KILL Pas
51. 6 Word 10 tag EPC 96bit area is measured It calculates by the calculating formula after that Communications Time Detection 6Word Multi Data Read 1 000 Mode1 RF TagReader Writer 40kbps e e Communication Time ms e 400 200 Number of Tags The baud rate for ModeO Auto mode is decided by the interference situation between two or more Reader Writer The baud rate in the state without interference completely becomes 160kbps RF Tag Reader Writer suoneoiunuiuo Calculating formula at Communication Time Multi Data Read Mode 0 7 0 0 1 32 13 9 0 8 65 Mode 1 13 9 0 3x w x n 65 Mode 2 T 7 1 0 1 x n 32 T ms w Count of words n Count of read tag s UHF RFID System 156 User s Manual SECTION 8 Reference data Receiving Level Detection You can obtain receiving levels of the signals sent from tags described at dB Step 0 125dB by specifying LVL option as tif parameter while the ID read command is executed In UHF band RFID system communication distance between a reader and tags depends on the direction of the tag surface types of tags or material of objects to which tags are attached This function enables the reader to measure rate of the impact due to the directions of tag surfaces circumstances or the material of the object As a reference following figure shows measurem
52. 7777777777777777 1 lt LF gt Example 4 When Password OxFFFFFFFF all memories are locked permanently is set Tx LOCK 1111111111 pwd FFFFFFFF lt LF gt Rx LOCK0000 001 lt LF gt The EPC code of the tag is 1234567890ABCDEF 12345678 Example 5 When Password 0x12341234 all memories are locked permanently is specified and specified password is incorrect Tx LOCK 1111111111 pwd 12341234 lt LF gt Rx LOCK7011 lt LF gt The communication error Code 7011 in this case is returned Example 6 When Password OxAAAAAAAA Lock code 22222222 is specified and specified lock code is incorrect Tx LOCK 2222222222 pwd AAAAAAAA LF Rx LOCK1412 LF The error code Code 1412 is returned UHF RFID System User s Manual SECTION 5 Command Line Interface Kill KILL E Command Format Command code SP Kill password SP Option 1 SP SP Option n K L pwd XXXXXXXX 4 1 13 1 n 1 1 n Item Description Specifies a KILL Password The password set previously in the Kill password area corresponding Kill password es When all 0 is specified the KILL command cannot be used The values other than 0 are set to KILL Password area before KILL Command is executed Option code Available Optional Value Communication sequence SOC Single Once Number of antenna Specifies order of antenna operation with figure 1 4 max 9 characters Process time out msec 0 or from 100
53. 9 224 02Fh OFOh RFU OFFh OEOh RFU OEFh Block5 User Password 15 0 ODFh Memory Bank 0 Block4 User Password 31 16 OAFh Bank 00 Block3 User Password 15 0 O9Fh Reserved memory Block3 User Password 31 16 08Fh 16word Block2 User Password 15 0 07Fh Block2 User Password 31 16 O6Fh Block1 User Password 15 0 05Fh Block1 User Password 31 16 04Fh Access Password 15 0 Access Password 31 16 02Fh Kill Password 15 0 Kill Password 31 16 OOFh UHF RFID System 34 User s Manual SECTION 3 Mode and Function Qo m E Function 37 T UHF RFID System User s Manual 35 SECTION 3 Mode and Function Mode Reader Operating Mode Reader operating mode contains three modes Operation Mode Safe Mode and Update Mode If you push the Mode Switch for 1 second or more and release the switch while the system is running or if the reader detects an error ex System error or a failure of firmware update and it can not start up normally due to this error the reader will start up under Safe Mode Under this mode you can check the status via Web browser initialize the setting and install the firmware Refer to the Ethernet Interface and RS 232C Interfacein detail CHECK 55 Safe mode SPOW Start with mode switch Operation mode Communication Mode The communication mode can be selected according t
54. FID System V750 BA50C04 US Reader Writer V740 HS01CA Normal type Circular Antenna V740 HSO1LA Normal type Linear Antenna User s Manual INAWNOOd SIHL GNVLSHUAGNN QV38 164 Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products Please consult your OMRON representative if you have any questions or comments WARRANTY OMRON s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year or other period if specified from date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE OMRON DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSI
55. L command has completed normally Tx KILL owd AAAABBBB ant 3 tif PER ANT lt LF gt Rx KILLOO00 001 30001234567890ABCDEF 12345678ABCD 3 lt LF gt The PC code of the tag is 3000 EPC code is 1234567890ABCDEF 12345678 CRC is ABCD and command executed Antenna ID is 3 o m O T Example 3 When Password 0x12345678 is specified and password data has been incorrect Tx KILL pwd 12345678 lt LF gt Rx KILL7012 lt LF gt The error code Code 7012 is returned Example 4 When Password 0x12 is specified and password length has been incorrect Tx KILL pwd 12 LF Rx KILL1421 lt LF gt The error code Code 1421 is returned UHF RFID System 88 User s Manual SECTION 5 Command Line Interface Communication command Exclusive commands for secure tag Lock Read LKRD E Command Format nd 1 6 1 n 1 1 n Description Specifies a lock type of an memory area intended to be controlled with double digits code shown as below EPC memory TID memory perma perma perma lock lock ne lock sorma Type of lock Lock Code read eck yp Unlocks permanently Locks temporally It can be unlocked 1 1 Locks permanently It cannot be unlocked No lock control U m O T Option code Available Optional Value Specifies order of antenna op
56. MOC When only RDID command is SRP MRP Firmware version 101 selected it can be selectable 101 102 0 or later Antenna ID 1 2 3 4 Time Out 250 500 1000 2000 Tag Info EPC EPC ANT EPC CNT EPC ANT CNT 1234567890ABCDEF12345678 When only WTID command is 111122223333444455556666 selected it can be selectable AAAABBBBCCCCDDDDEEEEFFFF 87654321FEDCBA0987654321 UHF RFID System User s Manual 2 Communication command input area CThe command selected by 1 is displayed in this area The command can be edited directly in this area 3 Response display area The response after the command is transmitted is displayed in this area Firmware Update Status Reader Settines Comm Settings Operation Settings Comm Test Utility Communication Test Command Sequence Antenna ID Time Out Tae Info RDID z 1 250 EPG ID 1234567890 ABCDEF12345678 nd Stop Clear First Response pom seq MOC ant 1 tmo 250 tif EPC 0001 RDIDOOOO 017 FFFFEEEEDDDDCCCCBBBBIO41 FFFFEEEEDDDDCCCCBBBB105 300833B2DDD901 4035050043 F 0002 RDIDOOOO 018 FFFFEEEEDDDD1506BBBB1031 FFFFFFFFFFFFFFFFFFFFFFFF 300833B2DDD901 4035050043 300 Count of RF Tag Second Response RF Tag ID Response code UHF RFID System User s Manual epojiy uondo 139 apo uondo 140 SECTION 6 Browser Based Interface Utility The V750 reader serves 3 function
57. Manual 1 m O 2 uieis S UHF RFID System User s Manual SECTION 2 Specifications and Performance 44 Reader Antenna 4 Specifications Gen2 Tags Memory Map 20 25 28 32 UHF RFID System User s Manual 6 NOILO3S 19 SECTION 2 Specifications and Performance Reader Names and Functions of Components Status Indicators PWR RUN ERR NORM ERC Mode switch RS 232C ETHERNET Control port Antenna port DC Power input RS 232C port Input Output port Antenna port Connects with UHF mono static type antenna specified by OMRON via Reverse TNC ANT1 ANT4 antenna cables Max 4 antennas can be connected to Control port For future expansion Exclusive connector CTRL PORT DC Power input Connects with the attachment AC adaptor to receive 12V electric power Exclusive connector POWER DC12V Extension of AC adaptor cable is not allowable RS 232C port Connects with the host via a commercially available RS 232C cable for DOS V D sub 9pin male RS 232C PC Inch screw 4 40 Ethernet port Connects with the host via a commercially available 10 100Base T cable HJ 45 ETHERNET LED Left Link Right Act Input Output port Connects to the input output signal cable s via an attached I O port adapter MC 1 5 10 GF 3 81 IN 1 2 3 4 C MC 1 5 10 STF 3 81 4 Inputs connects with the
58. One digit 00 None User input 11 RUN output The reader is running normally 12 ERR output The reader stopped with error 20 COM output The reader is communicating 2n ATn Current antenna s n21 to 4 The reader is communicating with specified antenna 31 NML Evaluated normal completion 32 ERC Evaluated completion with error occurring OutputTime 10 to 9990 ms 0 Status kept until upcoming evaluation Note Output time is effective only for NML ERC setting Condition Note Output time is effective only for NML ERC setting Note If the condition is omitted output signal shall be on without condition Refer to the following list Same as OT1 Same as OT1 Same as OT1 UHF RFID System User s Manual o m O pueuiuio Dunes 107 SECTION 5 Command Line Interface The format of status judgment expression 1 If the NML mode is specified in output function setting you can set conditions by using the following format Condition A Comparison symbol data DAT data to be read Condition B TCT tag count to be read Comparison operators 1 When comparison symbol data is DAT Left side data is equal to right side data Iz Left side data is not equal to right side data 2 When comparison symbol data is TCT Left side data is equal to right side data Iz Left side data is not equal to right side data gt Left side data is bigger than right s
59. Original production UHF RFID System User s Manual Terms and Conditions of Sale OMRON 12 Offer Acceptance These terms and conditions these Terms are deemed part of all quotes agreements purchase orders acknowledgments price lists catalogs manuals brochures and other documents whether electronic or in writing relating to the sale of products or services collectively the Products by Omron Electronics LLC and its subsidiary companies Omron Omron objects to any terms or conditions proposed in Buyer s purchase order or other documents which are inconsistent with or in addition to these Terms Prices Payment Terms All prices stated are current subject to change with out notice by Omron Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders Payments for Products are due net 30 days unless otherwise stated in the invoice Discounts Cash discounts if any will apply only on the net amount of invoices sent to Buyer after deducting transportation charges taxes and duties and will be allowed only if i the invoice is paid according to Omron s payment terms and ii Buyer has no past due amounts Interest Omron at its option may charge Buyer 1 1 2 interest per month or the maximum legal rate whichever is less on any balance not paid within the stated terms Orders Omron will accept no order less than 200 net billing Governmental Approvals Buye
60. P Connection No Connection Latest Comm Source Command Result Operation Time 00 00 57 Web Browser Via Web browser you can set following functions which can perform various works such as indicating an operation status or setting condition or setting an operation parameter 1 Reader Status Indicates current setting and operation status 2 Reader Settings Specifies a parameter for communication with host 3 Communication Settings Specifies a parameter for communication with tag 4 Operation Settings Specifies a command entry and programmable output conditions 5 Communication Test Executes a communication commands 6 Utility Provides some functions for easy installation and maintenance Latest Error Logging The function to display the latest error log History of Error Logging The function to display the counted error log Noise Check The function to monitor an on site environment Option Information The function to display the information of available options 7 Firmware Update Provides the method to update Note You can download Java software via following URL http www java com ja Java TM is trademark of Sun Microsystems UHF RFID System User s Manual 39 SECTION 3 Mode and Function Bi Digital Input Output Digital input Following two functions can be assigned to 4 digital inputs respectively To assign the function set via Set Operation window of command or Web 1 User
61. S CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED STORED INSTALLED AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION ABUSE MISUSE OR INAPPROPRIATE MODIFICATION OR REPAIR SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES Please refer to separate catalogs for OMRON s safety rated products OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of products in the customer s application or use of the product At the customer s request OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product machine system or other application or use The following are some examples of applications for which particular attention must be given This is not intended to be an exhaustive list of all possible uses of the products nor is it intended to imply that the uses listed may be suitable for the products Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion
62. SETR dhe 1 lt LF gt Rx SETROOOO lt LF gt Example 2 When Host name V750 BA50C04 IP 192 168 1 1 and Subnet mask 255 255 255 0 is set Tx SETR lhn V750 BA50C04 192 168 1 1 Inm 255 255 255 0 lt LF gt Rx SETROOO0 LF Example 3 When RS 232C Baud rate 19200bps Data length 7bit Parity Even Stop 1bit is set Tx SETR rbr 19200 rdt 7 rpb E rsb 1 lt LF gt Rx SETROOO0 LF o m O T Example 4 When the setting parameter is incorrect Tx SETR abc 111 lt LF gt Rx SETR1421 lt LF gt Dunes UHF RFID System User s Manual 103 SECTION 5 Command Line Interface Get Reader GETR Command Format Command code SP Parameter 1 SP SP Parameter 4 1 n 1 1 n Item Description Referred Setting value and Setting item are specified Refer to the Function condition setting of Reader Writer for details of setting item Parameter Response Format NN Response code SP Parameter1 SP SP Parameter 0000 Normal end For other Response codes refer to Response Code List IL p 71 Setting item Setting value Parameter 3 1 n o m O T Response code pueuiuio Dunes Setting value is connected by the equal sign 2 and specified the set item Refer to the Function condition setting of Reader Writer for details of a set item 101 UHF RFID S
63. Save Response L F Ethernet RS2320 C None Initial Exec 1 Input 1 Command RDID ANT 2 TMO 100 SEQ SOC Input 2 v Command RDID ANT 13 TMO 500 SEQ Input 3 Input 4 Programmable Output Output 1 Iv Function Output 2 Function Output 3 Function NML x Duration 5000 Conditions D AT FFFF31280000 Output 4 Function ERG Duration 1000 Conditions DAT 71727974 1 Command Entry Description The range of the set code Default Response Interface Interface selection to send response Ethernet RS 232C None Ethernet of the command Initial Exec Initial command executed Command characters None 71 automatically on booting Command executed when input port 1 Command characters is activated epojiy uondo Command executed when input port 2 Command characters is activated Command executed when input port 3 Command characters is activated Command executed when input port 4 Command characters is activated 1 The command can be inputted and registered to check the box in each timing Power up IN1 to IN4 UHF RFID System 136 User s Manual SECTION 6 Browser Based Interface 2 Programmable Output ltem Description The range of the set code Default Output 1 1 Function Programmable output 1 settings Output function synchronize with this RUN ERR COM ANT1 ANT2 port ANT 4 NML ERC Duration ms
64. System User s Manual 29 SECTION 2 Specifications and Performance External I O Specifications B Input Specifications Output Specifications IN1 IN2 IN3 IN4 OUT1 OUT2 OUT3 Item Specifications Item Specifications Input method Photo coupler Output method Open collector output Sync type NPN Input voltage 10 2 to 26 4 VDC Output maximum level 26 4 VDC including ripple including ripple Input impedance 2 35 TYP Leakage current 10 max Input current 4 5 mA TYP 24VDC Residual voltage 3 V max When output level is 13 mA 9 8 mA TYP 24VDC 2 V max When output level is 10 mA B I O Device Wiring Example Reader Writer Input Section suoneoyiooeds FAN eC IRE S NPN Transistor Open collector Output e g from a 3 wire Sensor Internal circuits Internal circuits Device with contact e g pushbutton switch Internal circuits Internal circuits Internal circuits Internal circuits co S 22 o 24 VDC Internal circuits ql Do not apply the over rated voltage to the input terminals Do not connect over voltage for its maximum rateing load to the output terminals CHECK UHF RFID System 30 User s Manual SECTION 2 Specifications and Performance Host communications specifications The reader can operate with Ethernet or RS 232C serial communiction from host computer or system Ethernet Co
65. Weight Aluminum 4 point screw M4 1 2 Approx 1 400 g E Normal type Antennas V740 HS01CA V740 HS01LA Ambient operating temperature Specification 15 to 60 C with no icing Ambient storage temperature 25 to 85 with no condensation Ambient storage temperature 25 to 65 C with no icing Insulation resistance Dielectric strength Dielectric strength Shock resistance 20 MQ min at 100 VDC mega between connector terminals and case 1 000 VAC 50 60 Hz for 1 min between connector terminals and case 10 to 150 Hz 0 7 mm double amplitude acceleration 10 sweeps in each of 3 axis directions up down left right and forward backward for 8 minutes each 150 m s2 3 times each in 6 directions Total 18 times Dimensions 256 x 256 x 57 mm W x H x D excluding Cable Degree of protection Antenna Connections Material Mounting IP53 IEC60529 4 channels Case PVC Base Panel Aluminum 4 point screw M6 Tightening torque 2 Weight UHF RFID System 28 User s Manual Approx 800 g SECTION 2 Specifications and Performance Communications Specifications B Reader Writer V750 BA50CO04 US Supported tag EPC global Class1 Generation 2 C1G2 UHF operating frequency 902 75 927 25MHz FHSS Frequency Hopping Spread Spectrum 50ch Antenna output 30dBm 4W EIRP Changeable for each antennas Connected antenna s V740 Series UHF Antenna x
66. When Getting 1 0 status is specified Tx EXIO lt LF gt Rx 100000 1011 1001 lt LF gt From the left side the following status is shown IN1 IN4 OUT1 OUT4 o m O T 041u02 UHF RFID System User s Manual 123 SECTION 5 Command Line Interface Good Bye GBYE This command enables to shut down connection with Ethernet After the reader received the command it returns the response that the command has received And the network connection is disconnected after 1 second E Command Format Command code Response Format Command code Response code Description 0000 Normal end For other Response codes refer to Response Code List I p 71 m O T Response code Command Response Example Good Bye GBYE GBYE lt LF gt GBYE RC LF RC Response Code 5 oJ1u02 Example 1 Disconnect the Ethernet connection between host and the reader Tx GBYE lt LF gt Rx GBYEOO00 LF UHF RFID System 124 User s Manual SECTION 5 Command Line Interface Request Resend RRES This command instructs the reader to re send the latest response data that has been sent This command shall not be accepted when the other command such as Repeat mode is being processed E Command Format Command code 4 E Response Format Command code Response code The latest re
67. When it is necessary the option is specified RDDT RC S CNT S Data 1 with ITM 1 S Data n with ITM n lt LF gt S Space code RC Response Code CNT Tag Count Data n with ITM n Data with Items indicated by TIF option Items are delimited by a comma Example 1 When Memory bank 0 Start address Data pointer 0 word count to be read Data length 1 is specified other settings are default value and then read process has completed successfully Tx RDDT 0 0 1 LF Rx RDDTOOO0 001 1234 lt LF gt Example 2 When Memory bank 1 Start address Data pointer 0 word count to be read Data length 8 is specified other settings are default value and then read process has completed successfully Tx RDDT 1 0 4 LF Rx RDDTOOO0 001 BCAD300055555555 lt LF gt If tif is specified for EPC code tag s EPC data before rewritten is returned If the tag had an EPC data 444444444444444444444444 as last ID response is as above o m O T Example 3 When Memory bank 1 Start address Data pointer 2 word count to be read Data length 3 Antenna 1 to 3 Tag information EPC and antenna id is specified and read process has succeeded Tx RDDT 1 2 3 ant 123 tif EPC ANT lt LF gt Rx RDDTOOO0 001 111122223333 1234567890ABCDEF 12345678 2 LF n this case the read data is 111122223333 the tag EPC code is 1234567890ABCDEF 12345678 and the read antenna ID is 2
68. able regardless of whether upper or lower case letters are used Any command works regardless the size combination of characters such as upper case letters lower case letters or mixed one ewo esuodseg pueuiuio UHF RFID System User s Manual 67 o m O T esuodseg pueuiuio 68 SECTION 5 Command Line Interface Composition of response frame B Response frame for RS 232C The shaded portion is only RS 232C 1 4 4 SOH Start Code Command Code Response Code Command Data FCS CR LF n 2 1 1 FCS Calculation Range Indicates the beginning of the frame with SOH For only RS 232C Specifies the command the reader executes Indicates the result code of command execution Indicates the result data of command execution Stands for Frame Check Sequence hereinafter referred to as FCS The code is to detect an FCS error The result of the horizontal parity calculation from after SOH through just before the FCS is expressed by two characters of ASCII code For only RS 232C Terminator CR ODh LF OAh It is only LF OAh when the command line is Ethernet E Response Format Command Code Response Code RE Too of ID or Data value 1 5 ce ID or Data value 4 4 1 3 1 n 1 1 n Digit Explanation number Command Code 4 Set same characters specified as a command sent from the host Response Code 4 Indicates four digit hexadecimal numbers by ASCII format Betwee
69. ablish key specifications for your application on your request Please consult with your OMRON representative at any time to confirm actual specifications of purchased products DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes even when tolerances are shown ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate however no responsibility is assumed for clerical typographical or proofreading errors or omissions PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user s programming of a programmable product or any consequence thereof COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission This document is protected by copyright and is intended solely for use in conjunction with the product Please notify us before copying or reproducing this document in any manner for any other purpose If copying or transmitting this document to another please copy or transmit it in its entirety UHF RFID System User s Manual INAWNOO d SIHL GNVLSYSGNN QV38 4 Introduction Safety Precautions e Signal Words Used in This Manual The following signal words and symbols are used in this manual to indicate precautions that must be observed to ensure safe use of the V750 series Reader Writer Unit The precautions provided here contain important safety infor
70. als orientation The communication range may reduce even if the materials which attached RF tag is not metal The communication range may vary by the orientation of the RF tag Above figure shows the communication performance with stanard RF tag orientation In the X marked orientation it can not be communicate or extremaly reduced the communication range Linear Circular 6 DX p 115 8 7 amp XFIORFA 27 OMAK lt E Ethernet Communication Erro When the connection with Ethernet has issues please check following LAN cable connected correctly Not use straight LAN cable when the reader and host PC connect directly When connect the reader directly to the host PC use crossover LAN cable When you forgot the IP address of the reader execute the following instruction Boot up the reader with Safe mode IP address for the Safe mode is alwasy fixed at 192 168 1 200 Set the IP address on the web brozwer I F 9 5 10119 FANCIES UHF RFID System 150 User s Manual SECTION 7 Troubleshooting Alarms and Errors Maintenance and Inspection The V750 Series Reader Writer and Antenna must be inspected on a daily or regular basis so that the functions of the V750 Series can be used in good condition The V750 Series consists of semiconductors that last almost indefinitely The following
71. and MOC Host Device Timeout Reader Writer RF Tag A sequence when the reader carries out the transaction and there is no tag At the end of the specified period the reader returns a response reporting no tag to the host Host Device Command MOC TimeOut Reader Writer Restpnse Read Process RF Tag A sequence when the reader detects tags for the specified period When it is not possible to communicate with all tag At the end of the specified period the reader returns a response reporting the read tags data to the host There is a possibility where tag that was not able to communicate exists too Command MOC Tag that was not able to communicate Host Device Timeout Reader Writer RF Tag UHF RFID System User s Manual U m O T eouenbeg 63 SECTION 5 Command Line Interface A sequence when two or more reader detects tags for the specified period When it specified multiple antennas for communication with RF tags the reader is priortized the communication with RF tags in the field within the timeout period If the number of RF tags in the field is enough small the reader can switch all antennas within the timeout period If the number of RF tags in the field is large and the reader can not finish the communcation with all these RF ta
72. at one command it returns the first receiving signal strength value Note This function is available in firmware version 102 102 103 0 or later L Please use these values which getting LVL option and its reference graph as a relative reaference only It can not gurantte the absorte value due the value may vary in variious condition such as RF tag used and sourrneded uonounJ HEC d environment UHF RFID System User s Manual SECTION 3 Mode and Function Session Setting The session flag which described in the EPC Global Class 1 Generation 2 air interface standard indicates the duration of keeping power on after the RF tag chip is shutted down such as it comes out from the antenna field It recommends to use as default settings in normal operation The default settings of the session flag are follows SO for communication sequence specified once access SOC MOC S2 for communication sequence specified repeat access SRP MRP lt can be settable based on the requirements of system operation Once Access Mode 50 Factory default setting Single Once In this setting the reader communicates with all tags existing in the Multi Once communication field whenever a command is executed 51 52 53 In this setting the reader communicates with un read tags it ignores once read tags If S1 is set tag refreshes its S1 flag when a specified time has passed after flag setting after communication transaction r
73. ation Time 02 29 19 Note1 1 is a display area in the state Product Type Type name of the product Fixed data V750 BA50C04 US Firmware version currently installed in the reader XXX XXX XXX X Serial Number Unique number for product set in the factory Fixed data MAC Address The reader s MAC address Fixed data Valid Antenna s Antenna s the reader has detected at start up Stable data that does not change In blue valid after start up In light gray invalid epojiy uondo Firmware Version Stable data if not updated firmware Support is provided for the firmware version 103 103 104 0 or later See below the Error code list for detail 1 Options Indicates effective options Indicates the reader s status with the following code Ready waiting for command Communicating command being executed Setting Error XXX YY Setting Error occurred System Error ZZ system error occurred Operation Status Indicates TCP IP port connection status No Connection Connected TCP IP Connection UHF RFID System User s Manual 131 SECTION 6 Browser Based Interface Latest Communication Indicates Active in orange if a command is being executed Latest Comm Source Interface name of command execution source It indicates the current command Ethernet RS 232C IN1 IN2 IN3 IN4 Web status by using command Ethernet RS 232C or the other registered command Com
74. ation and ripple are within the Oscilloscope 2 Ripple permissible ranges Mounting condition Check that each device is securely mounted No loose screws Check that each connector is fully inserted Each connector must be locked or securely tightened with screws Check that no screw of the terminal block is No loose screws loose Check that no wire is broken or nearly broken Must be no wire that is broken or nearly broken Check that the distance between the Tag and Within the specified range Antenna is within the specified range uonoedsuj pue PAN eee UHF RFID System User s Manual 151 SECTION 7 Troubleshooting Alarms and Errors Troubleshooting Check item of each Response code Response code Check item 5 there the communication condition setting between Host device and Reader Writer lt For Ethernet gt Does Ethernet Cable use the correct one Is the setting of Ethernet correctly set No correspondence For RS 232C gt Is the setting of RS 232C correctly set Baud Rate Data Length Stop Bit Length Parity Control code SOH FCS CR It confirms whether for Stop command STOP to become no response e Is not the command transmitted the way power supply ON or after the reset command is transmitted of processing about 2 5 seconds in the early 5 there the communication condition setting between Host device and Reader Writer Baud Rate Data Length
75. aw These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products without regard to conflict of law princi ples d Amendment These Terms constitute the entire agreement between Buyer and Omron relating to the Products and no provision may be changed or waived unless in writing signed by the parties e Severability If any provi sion hereof is rendered ineffective or invalid such provision shall not invalidate any other provision f Setoff Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice g Definitions As used herein including means including without limitation and Omron Compa nies or similar words mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof Certain Precautions on Specifications and Use 1 Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of the Product in the Buyers application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Prod uct in combination with the end product machine system or other applicati
76. become Example 1 When Memory bank 0 Start address Data pointer 0 Data 0x1234 one word is specified other setting are default and then the write process has been succeeded Tx WTDT 0 0 1234 lt LF gt Rx WTDTOOOO0 001 LF o m O T Example 2 When Memory bank 1 Start address Data pointer 3 Data 0x1234567890ABCDEF 12345678 Antenna 2 and Timeout 200 Tag information antenna id is specified Tx WTDT 1 3 1284567890ABCDEF 12345678 ant 23 tmo 200 tif ANT lt LF gt Rx WTDTOOO0 001 2 lt LF gt n this case the response code has an antenna ID which is used in writing process Example 3 When specified address is not supported Tx WTDT 1 8 12345678 LF Rx WTDTOOO0 000 lt LF gt No count response is returned Example 4 When specified address is locked Tx WTDT 0 0 AAAAAAAA LF Rx WTDTOOO0 000 lt LF gt No count response is returned Example 5 When Memory bank 1 Start address Data pointer 2 Data OXABCDEFGH is specified and a format error has occurred Tx WTDT 1 2 ABCDEFGH lt LF gt Rx WTDT1412 LF The error code Code 1412 is returned Example 6 When an error occurred during communication process Tx WTDT 1 32 1234567890ABCDEF 12345678 ant 23 lt LF gt Rx WIDT7011 lt LF gt The error code 7011 is returned UHF RFID System User s Manual 83 m O T
77. correctly Check and correct your settings The power off during executing the setting command or communcation settings error DHCP server connection error SECTION 7 Troubleshooting Alarms and Errors Operation Status Indicator ERR indicator blinking slow blinking Potential cause Countermeasure FER REN ERE The state of ready to The state of establishing connection O O O operate Or during execution on the command registration process via Ethernet I F ANTENNA 3 1 2 4 Oo B The operation error of the reader The operation error of the reader consists of the setting error and the command input error It can distigunish the error by checking the error code at the termination code on the response 1 Q Follow the instruction of Check item of each Response code of the Troubleshooting in this chapter A p 152 CHECK e Web browser I F shows error messages on its status windows Refer to this window and execute the adequate countermeasure The communication error with RF tags The communiction error comes from various situation such as insufficent anntenna installation or the environmental influences of mutul interferences between several reader and effects of reflections or setting error on the reader Also RF tag may cause the communication error such as the influences of materials and condition of which RF tag attached and orientation of RF tag The cause of insuffienct communica
78. cross cable to connect the PC to the port B Connector D sub 9pin male inch screw 4 40 Function Receive Data SD Send Data SG Signal Ground as c m gt Request to Send Clear to Send oO CO N Oo UHF RFID System User s Manual 21 22 2 Specifications and Performance 3 Ethernet Interface This port is used to connect the host to the reader via Ethernet To connect them use the commercial cable 10 10Base T Connector RJ 45 8 pin ACT LED LINK LED C C LED Link green Act orange Transmit Data TXD TXD Transmit Data OUT RXD Receive Data 4 Not used Reserved Not used Reserved RXD Receive Data Not used Reserved 2 3 4 5 6 7 8 4 I O Interface As an input output port the reader contains a terminal block of which connector is removable with Not used Reserved screws Terminal block connector MC 1 5 10 STF 3 81 produced by PHOENIX CONTACT Cable fixing screws x 10 IN OUT e 10 9 Terminal stand plug of attachment Function Output port 1 Output port 2 Output port 3 2 3 6 7 8 9 0 Input port 1 Input port 2 Input port 3 Input port 4 IN COM Input common port UHF RFID System User s Manual 5 Status Indicators
79. ctor For connection with Antenna Cable B Connector N Female connector Antenna cable is connected with the connector UHF RFID System User s Manual 25 SECTION 2 Specifications and Performance Demensions B V 40 HS01CA V740 HSO1LA 2567 ib 57 e 84 5 0 2 66 0 2 84 5 0 2 84 0 2 2567 o m O N 66 0 2 235 0 2 euugjuy 84 5 0 2 Mounting Hole 8 6 2 dia 3009 UHF RFID System 26 User s Manual SECTION 2 Specifications and Performance Antenna Cable E Demensions model V740 A01 3M V740 A01 10M V740 A01 20M length L1 3000 30 mm 10000 250 mm 20000 250 V740 A01 3M Shrinkage tube Shrinkage tube Label ks 5 um gt tet V740 A01 3 Bx ss 1 21 dia 5 CBE cuum 16 dia 5 n E 38 3 000 30mm V740 A01 10M Shrinkage tube Shrinkage tube 0006060606 ee e eet 21 dia 4 d D 4 09090 1 tet 1 0090909050 X 090905050004 0006000000 S RRR KKM 000000 900800000106 10 000 250mm V740 A01 20M Shrinkage tube Shrinkage tube 0505050909696 00 00004 00909099 te ette s 21 dia JE 06 09090990 0990990090069 20 000 250mm not bend antenna cable by force It could be a cause of beraking a wire S CHECK Suo Always use V740 A01 3M 10M 20M anntena cable
80. cuit or temporary execution error caused by noise Note1 x character in response code means one character in the list of O to 9 or A to F Note2 Depends on the specification of IC chip equipped in the RF tag It occurs at Monza chip when it specified the lock bit which does not exist in its memory map UHF RFID System User s Manual m O T ewo esuodseg pueuiuio 71 SECTION 5 Command Line Interface Command Specification E Parameters and Options for Communication Commands A communication command consists of parameter s mandated for command execution and option specified if necessary Following table shows parameters of each command and available options Command Data Options Parameters mandatory seq ant Read ID RDID Non Yes Yes Yes Write ID Write Data A Yes Read Data Memory Bank Data Pointer Data Length Yes Yes Write Data Memory Bank Data Pointer Write Data A Yes Lock Lock Code A Yes Kill Non A Yes All options can be omitted If option s is omitted the default value is applied depending on the option item Kill command requires the option item pwd if the pwd is not used in command 7Fxx error will occur E Parameter Details To set parameters items in the following list shall be chosen and be described in to the command one s way down the list Parameter Setting value Memory Bank Memor
81. curred Tx SETO 012 32 2000 71727A lt LF gt Rx SETOO000 LF Example 9 When output 1 function setting is deleted Tx SETO ot1 00 lt LF gt Rx SETOO000 LF UHF RFID System 110 User s Manual SECTION 5 Command Line Interface Get Operation GETO This command allows the reader to read the current operation conditions Even after setting operation command SETO is executed the old information shall be read out unless the reboot is completed Command Format Command code SP Parameter n Description Parameter can be specified only by one item Referred Setting value and Setting item are specified Parameter Refer to the Operation Setting for details of setting item Response Format Response code SP Parameter n U m O T Item Description 0000 Normal end For other Response codes refer to Hesponse Code List I p 71 Setting item Setting value 3 1 n Setting value is connected by the equal sign 2 and specified the set item Refer to the Operation Setting for details of setting item 106 Response code Dunes Parameter UHF RFID System User s Manual 111 SECTION 5 Command Line Interface Command Response Example Get Operation GETO GETO S param lt LF gt S Space code param Setting item is specified by the sign GETO RC S param value lt LF gt
82. cution gt INAWNOO d SIHL GNVLSYSGNN QV38 4 This Product is not designed or rated for ensuring safety of persons Do not use it for such purposes UHF RFID System User s Manual Introduction Regulatory Compliance 1 EMC 47 CFR Part 15 RSS210 COFETEL RCPOMV708 0153 FCC WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC COMPLIANCE This equipment complies with Part 15 of the FCC rules for intentional radiators and Class A digital devices when installed and used in accordance with the operation manual Following these rules provides reasonable protection against harmful interference from equipment operated in a commercial area This equipment should not be installed in a residential area as it can radiate radio frequency energy that could interfere with radio communications a situation the user would have to fix at their own expense COFETEL WARNING This equipment operates on a secondary basis and consequently must accept harmful interference including from station of the same kind and may not cause harmful interference to systems operating on a primary basis EQUIPMENT MODIFICATION CAUTION Equipment changes or modifications not expressly approved by OMRON Corporation the party responsible for FCC compliance could void the user s authority to operate the equipment and could create a hazardous condi
83. distribution control It is designed to have High read range Quick response and Simple operation a 9 Net work PLC qg 150 RS 232C Dock door Conveyor system y system EB F N E DCN 2 i ZA wil N 5 xU SU Multiple readers and antennas located in proximity or other UHF readers and antennas at neighborhood may cause intereferences for detoriating communication performance Please check your operating environmental before you start to use CHECK UHF RFID System User s Manual SECTION 1 Features and System Configuration System Configuration Max imum 4 antennas can be connected to the reader Sensor input can be applied to external inputs at the reader as a trigger input for starting communication with the tag and then it can output to its external outputs for controlling such as indicators or buzzer according to its communication results o m O Photoelectric sensor I O Device Host Device Lamp Buzzer PC Personal computer PLC _lojojofofofofofofofo _ Em uieis S V750 Reader Writer AC Adaptor Accessory Antenna Cable Option Cable Length 3m or 10m or 20m Four antennas or less can be connected UHF RFID System User s
84. e options When it is necessary the option is specified WriteData Data to be written in 4 digit hexadecimal number Max 128 characters WTID RC S CNT S ITM 1 S ITEM n lt LF gt S Space code RC Response Code CNT Tag Count ITM n Items indicated by TIF option Items are delimited by a comma Note If EPC PEP PER are specified for TIF EPC data shall be the data before rewrite If data length is zero during EPC specification data shall become Example 1 When all option values are default values and ID 1234567890ABCDEF 12345678 is specified the command is executed and write process has been completed successfully Tx WTID 1234567890ABCDEF 12345678 lt LF gt Rx WTIDOOO00 001 lt LF gt Example 2 When ID 555555555555555555555555 and EPC code are specified for write data and tag information the command is executed and then the reader has succeeded Tx WTID 555555555555555555555555 tif EPC lt LF gt Rx WTIDOO00 001 444444444444444444444444 lt 1 gt If tif is specified for EPC code tag s EPC data before rewritten is returned If the tag had an EPC data 444444444444444444444444 as last ID response is as above o m O Example 3 When 1234567890ABCDEF 12345678 and antenna specified for write data and tag information the command is executed and then the reader has succeeded to write data with antenna 1 Tx WTID 1234567890ABCDEF 12345678 tif EPC ANT lt LF g
85. e connected 134 Time hh mm ss max 9999 59 59 ex Passage of 34 seconds for 12 minutes 00 12 34 Firmware version Version of the firmware is read Transition time from kick Transition time U m O T The number of the optional feature that can be used is Option number Option number comma separated values Support is provided for the firmware version 103 103 104 0 or later Parameter that can be specified by SETR and GETR Reader Infomation pueuiuio Dunes RNM Reader name Name of user definition max 63 characters ASCII None HRL Readers role Name of user definition max 63 characters ASCII Ethernet Port number of use PRT TCP IP Port 2 ports are used specified port command control and specified port 1 Web Function Name on the network max 63 characters ASCII Sent to DHCP server when IP is acquired V S0 BAS0C04 US Host Name Network domain name max 67 characters ASCII Sent to DHCP server when IP is acquired DHCP Enable 0 Disable 1 LAN IP Address IP address when using static network settings 192 168 1 200 LAN Net Mask Subnet mask when using static IP address 255 255 255 0 Default Gateway Default gateway when using static IP address 192 168 1 254 RS 232C baud rate 9600 19200 38400 57600 bps 7 7 bit 8 8 bit Domain Name RS 232C data length
86. e used for enclosing Example 1 When Antenna port 1 UHF power Gen2 session value for Once Mode Reading is read out Tx GETC pw1 ss1 lt LF gt Rx GETCO000 pw1 10 ss1 1 lt LF gt o m O T Example 2 When Filter setting Filter condition 1 Filter condition 2 is read out Tx GETC fte 1 ft2 lt LF gt Rx GETCOOO0 fte 1 amp 2 ft120 1 8 2 CO ft2 0 1 20 16 125A lt LF gt Dunes UHF RFID System User s Manual 11 SECTION 5 Command Line Interface Save communication setting SAVE This command allows the reader to write communication setting into the nonvolatile memories in the reader If SET Communication command SETC is executed and then the reader is started up without executing this command SAVE new setting will be abandoned Command Format Command code s A v E 4 Response Format Response code Item Description 0000 Normal end For other Response codes refer to Hesponse Code List I p 71 Response code o m O T Command Response Example Get Communication GETC Command SAVE lt LF gt SAVE RC LF RC Response Code Response pueuiuio Dunes Example 1 When communication setting is saved New setting is written into the nonvolatile memory Tx SAVE lt LF gt Rx SAVE0000 lt LF gt UHF RFID System 11 User s Manual SECTION 5 Comma
87. ecified in the SET Communication command SETC and GET Communication command GETC Specifying following option allows the reader to set or read the communication condition To write the setting data into the nonvolatile memories in the reader SAVE command SAVE shall be executed Code Description Factory setting RF Control Gen2 Session value 1 Gen2 Session Once Gen2 Session value 2 Gen2 Session Repeat UHF power level at port 1 In case of Once Mode sequence In case of Repeat Mode sequence Session value of SOC MOC sequence 0 1 2 3 Refer to the Session Setting for details of Session I p 46 Session value of SRP MRP sequence 0 1 2 3 Refer to the Session Setting for details of Session 46 The output value of the antenna is set 31 5 dBm UHF power level at port 2 Same as PW1 31 5 dBm UHF power level at port 3 Same as PW1 UHF power level at port 4 Same as PW1 dBm dBm 31 5 dBm 31 5 dBm Communication mode Baud rate from tag is set 0 Normal mode 1 Dense reader mode DRM U m O T 0 Normal mode EPC word length EPC word length total word length of PC EPC of tag for the communication is specified Refer to the Gen2 Tags Memory Map for details IU p 32 0 Auto mode 1 to 32 Fixed length mode Auto mode judges the EPC word length from the automatic operation while communicating with tag 0 Au
88. ectly you can recover the reader by boot up with Safe mode VA Do not power down the reader during firware update It cause of failure to boot the reader e CHECK UHF RFID System User s Manual uonounJ 43 uonounj 44 SECTION 3 Mode and Function EPC Word Length The function of setting EPC owrd length can be set by specifying the option EWL in the communication setting command SETC It can also be read by the command GETC with the option EWL V EPC word length can be set get thorugh the Communication condition Settings window in the Comminction condition setting described at the SECTION 6 gt CHECK VAN 134 The length shall be set with 0 as an auto mode or a number from 1 to 32 as fixed length mode Default value is 0 auto mode For fixed length mode set a total number of tag s PC length constantly 1 and EPC word length R W measures the EPC word length of the tag automatically and sets the most suitable value Generally use this mode O auto mode 1 to 32 fixed length mode R W communicates with the tag depending on the set value If you have a word length of the tag to be read before hand use this mode The value must be the greatest of the EPC word lengths of the tags to be read Ex1 When EPC word length of a communicating tag is unknown set EPC word length to 0 auto mode Tx SETC ewl 0 Rx Ex2 Wh
89. ed the reader which certification number has 001AHB1004 or 001PVAB1002 The reader which certification number is 001AHBO01 can not use this function This command is only valid for Secure function command The EPC global Class1 Generation2 RF tag which does not support secure function does not respond to this command Command Code Command Name Description 1 Communication command Exclusive commands for secure tag LocK ReaD ReadLock Forbids reading data by bank unit UII TID USER Executabl ein communic ation Write Multiple Words WriteMultipleWords LocK Block BlockLock Writes data into a maximum 8 word area at a time Locks up the USER area s by block unit WTPW LocK Read Block BlockReadLock ReaD System Information GetSystemlnfomation Set ATTenuate SetAttenuate WriTe PassWord Forbids reading data in the USER area s by block unit Reads information of targeted secure tag including lock information Changes communication distance between the antenna and the secure tags Writes the USER password into tags NO word shown in parentheses corresponds to the command name used in Secure Tag Hibiki protocol UHF RFID System User s Manual Response Code List Response Code Category Response Name SECTION 5 Command Line Interface Description Normal end 00 00 Normal end The received command
90. egardless of whether tag energized or not It means that the tags are read repeatedly in a certain interval If S2 or S3 is set tag refreshes its S2 or S3 flag when a specified time has passed after tag energizing stopped It means that the tag is not re read unless the tag stays out of the communication field for the specified time Repeat Access Mode 52 Factory default setting Single Repeat In this setting the reader communicates with new detected tags existing in the Multi Repeat communication field during the command execution S0 When there is a tag the reader can not read because of flag conflict with other uonounj readers this setting enables the reader to read the tag 51 53 If another reader set in the previous process line uses S2 flag the reader same flag may encounter the flag conflict 51 and S3 flags are used to avoid this conflict Setting S3 provides same operation as S2 setting If S1 is set tag refreshes its S1 flag when a specified time has passed after flag setting after communication transaction regardless of whether tag energized or not It means that the tags are read repeatedly in a certain interval 1 The read rate may drop when the session flag is set to SO for the communiction seqeunce with repeat SRP MRP due the reader communcates with several times with the same RF tag and it increase the communiction time Also it may cause the reader halt error system setting error due to the i
91. en EPC word length of a communicating tag is known beforehand set the word length For example set it as follows when all EPC length of a communicating tag are 96bit 6 words Tx SETC ewl 7 Rx SETCO000 If the number of tags to be read is two or more and each tag has different EPC length set the greatest number of the EPC word lengths of them d RF Tag RF Tag RF Tag C EPC 6 words EPC 10 words EPC 4 words Set it to 11 PC 1 word and EPC 10 words Tx SETC ewi 11 Rx SETCO000 Note If you set the smaller value than the actual EPC word length communication precision may be decreased Note This function is available in firmware version 102 102 103 0 or later UHF RFID System User s Manual SECTION 3 Mode and Function E Receiving Level Detection It can get the receiving signal strength from the RF tag dBm unit 0 125dBm step by specifying the option LVL in the tif paraemeter on the ID read command In the UHF RFID system the communication range varies by the influences of materials and condition of which RF tag attached and orientation of RF tag and type of RF tags etc This function can be useful to measure these influnces on RF tag This graph of the communiction diagram in the Reference data at SECTION 8 shows the the receiving signal strength vs distance between antenna and HF tag for the reference CHECK UA p 157 Note that if the reader can communicate multiple times
92. ended normally with no error 10 00 Parity error A parity error has occurred in one of the characters of the command frame For only RS 232C is 00 Framing error A framing error has occurred in one of the characters of the command frame For only RS 232C 12 00 Overrun erro An overrun error has occurred in one of the characters of the command frame For only RS 232C 13 00 FCS error The command frame has an incorrect FCS For only RS 232C OX Command code Incorrect command has been received The response code is ICMD See Note1 error 1X Command Command 14 Command parameter is incorrect enor See Note1 parameter erro 2X Command option E Command option is incorrect See Note1 error Process error Specified command can not be executed 00 Ex Caused by executing a communication command when the last command is being executed 15 Ex Caused by incorrect setting of filtering condition OX Filter error Specified filter settins is incorrect See Note1 Ex Caused by incorrect setting of filtering condition 18 00 Frame length error A command received from the host exceeds the receive buffer 512 Bytes 00 LBT busy error Channel none by can LBT use The electric wave cannot be sent Communication During the transaction after tag detection communication error or 1X error process time out has occurred and consequently the transaction can See Note1 not be completed normally 70 Specified password does not match to the
93. ent results of receiving levels when the distance between the antenna of the reader and tag is simply changed E Measurement condition at Receiving Level environment Anechoic Chamber Distance 100cm to 480cm Distance from antenna to tag Condition Antenna Circular antenna V740 HS01CA Reader s output 28 5dBm Receiving level dBm Distance cm 9 9 When the distance between the reader antenna and tags becomes double the receiving level of signals is attenuated by about 6dB This function is available in firmware version 102 102 103 0 or later UHF RFID System Users Manual 15 uonoojeg 158 MEMO UHF RFID System User s Manual SECTION 9 Appendices Accessory 160 Degree of Protection 161 V m O RFID System User s Manual 159 SECTION 9 Appendices Accessory Reader s accessory No name model Number 1 Adapter External Input Output terminal MC1 5 10 STF 3 81 procuced by PHOENIX CONTACT Instruction sheet a Instruction sheet for accessories lt Explanation gt 1 AC Adapter Always use this AC adpater when you power the reader 2 External Input Output terminal plug Always use this terminal plug when you wired the external signal input output from the external devices 3 Instruction sheet Read this instruction sheet carefully befo
94. er shall read the input and output status E Command Format Command code SP OUT E x 1 o 2 4 1 4 The output signal of OUT1 to 4 is set 0 OFF 1 ON It is possible to omit The output change of OUT is not done when omitting it E Response Format Response code m O T 0000 Normal end For other Response codes refer to Response Code List I p 71 State of IN1 to 4 0 OFF 1 ON State of OUT1 to 4 0 OFF 1 ON 5 5 RFID System 122 User s Manual SECTION 5 Command Line Interface Command Response Example External Input Output control EXIO EXIO lt LF gt For input output port status read EXIO S OutputSignal lt LF gt For output status specifying S Space code OutputSignal For OUT1 4 values are set with four characters left to the right 1 4 0 OFF 1 ON Don t care EXIO RC S InputSignal S OutputSignal lt LF gt RC Response Code 0000 Fixed S Space code InputSignal For IN1 4 signal values 0 or 1 are set with four characters left to the right OutputSignal For OUT1 4 signal values 0 or 1 are set with four characters left to the right 0 OFF 1 ON Example 1 When Output 1 High Output 2 Low Output 3 High Output 4 Low is specified Tx EXIO 1010 Rx 100000 1111 1010 Example 2
95. eration with figure 1 4 max 9 characters The figure 1 to 4 is antenna s identical number Number of antenna 0 or from 10 to 2550 in 10msec increments in DRM off mice ce 0 or from 10 to 10000 in 10msec increments in DRM on Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail Lz p 73 Specifies a password with 8 digit hex number 32 bit word It is essential unless the value in the area of tag Access Password is zero Access password 10 UHF RFID System User s Manual 89 SECTION 5 Command Line Interface E Response Format Response code SP Tag count SP TIF information u 4 4 1 3 1 n Item Description 0000 Normal end For other Response codes refer to Hesponse Code List I p 71 Response code Tag count Count of locked tag s Tif information specified with command TIF information M cee Each optional value for tif information lines with comma separation Secure function is supported by certificication number at 001AHB1004 001PVAB1002 The reader which certification amp number is 001AHB1001 can not use this function Also
96. es by the difference between the kind of the command and the communication specification B 1 1 Protocol When Single once Setting of communication condition and Setting of Reader Writer etc are specified by the command that communicates with the RF tag one response is transmitted to one command Host Device Reader Writer B 1 N Protocol When Single repeat and Multi repeat etc are specified by the command that communicates with the HF tag two or more responses are transmitted to one command Host Device Response Reader Writer UHF RFID System 60 User s Manual SECTION 5 Command Line Interface Communication Sequence In order to communicate with the RF Tag in the communications area of the Antenna commands must be selected and used according to the mode and movement of the RF Tag Single Access Mode In this mode only a single RF Tag can be in the communications area otherwise the result of the first communication with tag replies E Single Once The reader reads a single tag at a time One to one communication When the reader detects the first tag it returns response and terminates transaction one response one transaction If the reader does not detect any tag it continues the process for a specified period of time In this case the response indicates 0 as the number of tags If the period is not specified it continues the process until the termination command
97. figure 1 4 max 9 characters Process time out msec 0 or from 100 to 5 000 in 10msec increments Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail UA p 73 Specifies a password with 8 digit hex number 32 bit word It is essential unless the Access password value in the area of tag Access Password is zero It is active only when the area specified by tag is locked for read and write Data pointer Data Length Communication sequence m O T Tag protocol 1 E Response Format Data and Data Response code Tag count SP TIF information TIF information Description 0000 Normal end For other Response codes refer to Response Code List 71 Response code Tag count Count of read tag s Data read from tag and Tif information specified with command D nd TIF information n Each optional value for tif information lines with comma separation UHF RFID System 80 User s Manual SECTION 5 Command Line Interface Command Response Example Read Data RDDT RDDT S mbk S dpt S din S options lt LF gt S Space code mbk Memory Bank dpt Data Pointer din Data Length options
98. gle RF tag in the field and for multi access mode which communicates with multiple RF tag in the field You can also specified anntenna to be used and communiction duration as a communication parameters Mode Single Access Mode Multi Access Mode RF Tag in the Communication field Repeat Once Repeat SRP MOC MRP Single Repeat Multi Once Multi Repeat Repeat Once parameter SOC Single Once Reader control command The command is used to set the pramater of the reader device or communiction settings for the communication with RF tag As a setting of commmuniction with RF tag it includes the filtering setting which provides communiction with specific RF tag according to the filtering settings e Maintenance command The command is used to control the reader opration It includes the reader setting initilatization terminating command execution and control the input output port for controlling the external devices UHF RFID System User s Manual uonounJ uonounJ SECTION 3 Mode and Funct Self Ope ion ration The self execution function provides the stand alone solution to read RF tag and control the external output according to the result of reading tags without host controller The registered command can be issued by triggerring external input such as sensors The result of communiction or reader status can be outputted to external ouput Command entry The e
99. gs during switching all antennas the reader responds the RF tags read data at the time of time out even if it do not switch the all antennas Command MOC Host Device Timeout Reader Writer HF Tag Communication area of Antenna 3 o m O T oouenbes UHF RFID System 64 User s Manual SECTION 5 Command Line Interface E Multi Repeat The reader reads multiple tags for a specified period At the end of the specified period it returns read results to the host and then it begins the next transaction until termination command has been sent At each period the reader returns all read tag s results to the host If it does not read any tag during each time period it returns response meaning there is no tag A sequence when the reader detects tags repeatedly At the end of the specified period the reader returns a response reporting the read tags data to the host Timeout Timeout Timeout TT TT MEM Response EE Response EE Response Two or more RF Tag Two or more RF Tag Two or more RF Tag Command MRP Host Device Reader Writer RF Tag A sequence when the reader carries out the transaction repeatedly and there is no tag At the end of the specified period the reader returns a response reporting no tag to the host Command MRP Timeout Timeout Timeo
100. has been sent or until it detects a tag A sequence when the reader detects one tag for the specified period Just after the reader communicates the tag it returns a response reporting the read tag data to the host EET Host Device Command SOC Reader Writer RF Tag RF Tag Timeout A sequence when the reader does not detect any tag for the specified period There is no tag At the end of the specified period the reader returns a response reporting no tag to the host Command SOC Timeout Host Device Response Reader Writer RF Tag A sequence when the reader detects two or more tags for the specified period Just after the reader communicates first the tag it returns a response reporting the read tag data or reporting no tag to the host Host Device Command SOC as Reader Writer RF Tag RF Tag RF Tag RF Tag Timeout UHF RFID System User s Manual U m O T eouenbeg 61 SECTION 5 Command Line Interface E Single Repeat The reader communicates with a single tag at a time one to one communication and repeats the communication transaction When the reader detects the first tag it returns response to the host then it begins the next transaction repeatedly Whenever it detects an unread tag it reads the tag and returns read results to the host It repeats the transaction until the termination command
101. ide data lt Left side data is smaller than right side data Comparison data 1 When comparison symbol data is DAT XXXX Hex X 0109 Ato F e mark is a wild card When the data length is different the result shall be incorrect When the command has tif option comparison symbol data DAT has all tag information that the reader read When comparison symbol data is specify with mark 2 When comparison symbol data is TCT 0 to 999 Logical operator 8 AND operator Format condition A amp condition B OR operator Format condition A condition B m O T f there is no condition to be set the output signal shall be on after normal end If there is no condition to be set or condition is set condition B shall not be included in the setting Ex When the read data is 12bytes 24character and the characters from 5th to 8th in it is 0000 or when the number of tags is 8 or more DATS 0000 SUTSIOTIsS pueuiuio Dunes 2 If the ERC mode is specified for output function setting you can set conditions with the following format Condition Comparison symbol data DAT error code Two characters from the head in error code ICT is not supported Comparison operators matched When the error code is in specified error code list Iz unmatched When the error code is not in specified error code list Comparison data It s
102. igh pres Water is jet sorayed at any angle towards the product pressure water jet spray sure water jet spray approach for 1 min per square meter for at least 3 min in total uu ing at any angle towards the from the test machine product 2 5 100 liter min 7 IL s Discharging nozzle 6 3 dia Protection underwater Resists the penetration of The product is placed 1 m deep in water if the product water when the product is is 850 mm max in height for 30 min inl placed underwater at speci M fied pressure for a specified time Protection underwater Can be used continuously The test method is determined by the manufacturer and underwater user Oil resistance OMRON in house standard Protection Oil resistant No adverse affect from oil drops or oil spray approaching from any direction Oil proof Protects against penetration of oil drops or oil spray approaching from any direction Note This OMRON in house standard confirms resistance to cutting and other oils It is equivalent to the former JEM standard UHF RFID System User s Manual MEMO UHF RFID System uonoojo4d 163 164 Revision History A manual revision code appears as a suffix to the catalog number at the bottom of the front and rear pages Man No Z235 E1 01 Revision code April 2012
103. in any way with respect to the Products Without limiting the foregoing Buyer at its own expense shall indemnify and hold harmless Omron and defend or set tle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party Property Confidentiality Any intellectual property in the Products is the exclu sive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron Notwithstanding any charges to Buyer for engineering or tooling all engineering and tooling shall remain the exclusive property of Omron All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party Export Controls Buyer shall comply with all applicable laws regulations and licenses regarding i export of products or information iii sale of products to forbidden or other proscribed persons and ii disclosure to non citizens of regulated technology or information Miscellaneous a Waiver No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron b Assignment Buyer may not assign its rights hereunder without Omron s written consent c L
104. included when you open the box at first gt CHECK UHF RFID System 50 User s Manual SECTION 4 Diagnosis and Maintenance Reader Writer Setting Ethernet Setting When you connect the reader via Ethernet I F the default setting of the reader are shown as below Please check the setting of Ethernet at host system when you connect IP Address 192 168 1 200 Subnet Mask 255 255 255 0 Gatewey 192 168 1 254 Communication Port 7090 RS 232C Setting When you connect the reader via RS 232C I F please check the communication setting for both the host system and the reader Baud Rate 9 600 19 200 38 400 57 600 57 600 bps Data Length 7 8 bit 7 bit Parity Bit Even Odd None Even otop Bit 1 2 bit 2 bit uias Initialization of setting It can return to default setting by sending initialize command INT VL When you issue the command refer to Command Line Interface in the SECTION 5 CHECK p 59 UHF RFID System User s Manual SECTION 4 Diagnosis and Maintenance Installation Environment Since the protection grade for the reader is IP50 and the standard antennas is IP53 IEC60529 it can be installed only indoor environment within the protection grade It needs to be refer to following instructions to get the system reliability and the system performance Location Do not use the Product in the following locations
105. ing threshold values 0 Disable Enable Disable Omit Response 3 Omits response for no tag This function enables the reader to respond one time for each reading RF tag data even if the reader communicate several times continously for the purpose to reduce the network trafic or to simplify the programming The reader buffered the RF tag data which once read and no longer respond the data to the host system during its data in the buffer The setting value is the number of RF tags to be buffered The buffered data will clear at the timing when the reader receive the command completion such as the timing to receive STOP command 4 This function enable not to respond the no tag response if the RF tags do not exist in the field All parameter modified are vailid after clicking Apply button and these are effective from next command execution The settings are applying on each items step by step with following order RF control Filtering Smoothing If the settings scuess the item turns in blue and if it has error it turns in red If the error happened on particlar items it and following items are not changed If you click the Store button following Apply button the settings are stored in the internal memory and its effective for next boot up UHF RFID System User s Manual 135 SECTION 6 Browser Based Interface Operation Settings Click to save the settings Operation Settings Command Entry
106. ion Command Line Interface Control method 5 Lom Q c 5 Communication Sequence Command Response Format Communication Command Communication command Exclusive commands for secure tag Setting Command Control Command Undefined Command Browser Based Interface Using the Browser Based Interface Option Mode Safe Mode Troubleshooting Alarms and Errors Errors and Countermeasures Maintenance and Inspection Troubleshooting Reference data Communications Time Receiving Level Detection Appendices Accessory Degree of Protection Revision History UHF RFID System User s Manual 59 60 61 66 76 89 101 119 128 129 130 131 145 147 148 151 152 153 154 157 159 160 161 164 SECTION 1 Features and System Configuration L NOILOAS Features 14 System Configuration 16 UHF RFID System User s Manual 13 o m O SsoJnjeo SECTION 1 Features and System Configuration Features The OMRON V750 RFID Reader herein after denoted as the reader uses RFID radio frequency identification technology to read data stored on RFID tags The reader supports UHF ultra high frequency antennas which are available separately The reader receives tag data through the UHF antenna and transfers data to a remote computer over a network connection E Main Features 1 Well tuned communication performance and functions for custome
107. ion condition setting of Reader Writer for details of setting item Parameter Response Format Response code SP Parameter1 SP SP Parameter o m O T 0000 Normal end Response code For other Response codes refer to Hesponse Code List pueuiuio Dunes Setting item Setting value Parameter 3 1 n Setting value is connected by the equal sign 2 and specified the set item Refer to the Function condition setting of Reader Writer for details of a set item I p 101 UHF RFID System 116 User s Manual SECTION 5 Command Line Interface Command Response Example Get Communication GETC GETC S Param1 Value1 S S ParamN ValueN lt LF gt S Space code param Setting item is specified by the sign GETC RC S Paramt Value 1 S S ParamN ValueN lt LF gt RC Response Code ParamN ValueN Setting item and value S Space code param Setting item is set by the sign Response value Setting value is connected by equal sign 2 and specified If multiple items are specified the reader shall return response with connecting specified items to the setting values with equal in the specified order Alphabetical characters included in the item name in the response shall be small characters e f the setting item is ft1 or 12 the five items shall be returned with space separation between each item Double quotations shall not b
108. ion distance will be reduced when the Unit is not mounted to a metallic surface 5 RF Tag cannot be washed the high temperature 6 Do not drop the device you may receive major shocks Doing so may result in personal injury or device damage 7 Do not apply strong force to or place heavy items on the device or cables Doing so may deform or damage the device resulting in electric shock or fire 8 Use and store the product in an environment that is specified in the catalog or User s manual Failure to do SO may cause failure of the device electric shock or fire 9 When transporting the Units use special packing boxes 10 Be careful not to apply excessive vibration or shock or not to expose to water during transportation and not to drop the product 11 Provide an enough space around the device for ventilation 12 Be sure to use wiring cable of the specified size for wiring Failure to do so may cause failure of the device electric shock or fire 13 AC adaptor of the attachment is used without fail Failure to do so may cause failure of the device electric shock or fire 14 After the DC connector side is connected the AC100V side is connected when the AC adaptor is connected Failure to do so may cause failure of the device electric shock 15 The product uses a publicly available ISM frequency band of 902 928MHz to communicate with Tags some transceivers motors monitoring devices power supplies and other similar RFID system
109. ions subject to spray of water oil or chemicals B Cleaning Do not clean the Products with paint thinner or the equivalent Paint thinner benzene acetone and kerosene or the equivalent will dissolve the resin materials and case coating INAWNOO d SIHL GNVLSYSGNN QV38 UHF RFID System User s Manual Introduction Meanings of Symbols 1 e Indicates particularly important points related to a function including precautions and application advice o gt CHECK il zi Indicates page numbers containing relevant information s oqui S jo 2 Indicates reference to helpful information and explanations for difficult terminology UHF RFID System 10 User s Manual Introduction Table of Contents 5 p Q c O 5 E Introduction READ AND UNDERSTAND THIS DOCUMENT 2 Safety Precautions 4 Regulatory Compliance 6 Precautions for Safe Use 7 Precautions for Correct Use 8 Meanings of Symbols 10 Table of Contents 11 Features and System Configuration 13 Features 14 System Configuration 16 Specifications and Performance 19 Reader 20 Antenna 25 Specifications 28 Gen2 Tags Memory Map 32 Mode and Function 35 Mode 36 Function 37 Diagnosis and Maintenance 49 Connection of Reader and each equipment 50 Reader Writer Setting 51 Installation Environment 52 Installation and Wiring 53 Wiring for cable 55 UHF RFID System User s Manual 11 Introduct
110. its and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail I p 73 Specifies a password with 8 digit hex number 32 bit word Access password Itis essential unless the value in the area of tag Access Password is zero It is active only when the area specified by tag is locked for read and write Tag protocol 1 Gen2 E Response Format I Command code Response code SP Tag count SP TIF information Oe 4 4 1 3 1 n Item Description 0000 Normal end For other Response codes refer to Hesponse Code List I p 71 Tag count Count of written tag s eounoes 10 aAIsn ox3 Response code Tif information specified with command Each optional value for tif information lines with comma separation TIF information Secure function is supported by certificication number at 001AHB1004 001 1002 The reader which certification amp number is 001AHB1001 can not use this function Also Secure function can only use for the RF tags which supports Secure RFID protocol The standard EPC global Class Generation 2 RF tags does not work UHF RFID System User s Manual 91 SECTION 5 Command Line Interface Lock Block LKBK E Command Format Command code SP Block SP User password SP Lock code SP Option 1 SP SP Option n L K B K number Item
111. mand The command code that is being executed It indicates the executed command Ex RDID ANT 1 TMO 1000 Result Executed result Command response code and the number After communication completed the of tags response are shown It remains Ex RDIDOOOO 001 blank if the command is being executed or has not been executed yet Operation time Time past after start up Time starts with 00 00 00 at the Ex 01 23 45 start up If the time exceeds 9999 59 59 the indication returns 00 00 00 Note2 Error code detail for the reader status Note1 In case of Setting Error the error cause is shown by both character and its code Status code YY Description XXX Error type DHCP Server DHCP Server error Comm Settings Communication setting error m 2 Operation Settings Operation setting error Reader Settings Reader setting error 36 apoly uondo UHF RFID System 132 User s Manual SECTION 6 Browser Based Interface Reader Settings Firmware Update OMRON Status Reader Settines Comm Settings Operation Settings Comm Test Utility Reader Settings Reader Information Reader Name GateReaderl Reader Role Ethernet Host Name 50 Reader1 Domain Name DHGP OFF C ON 021681200 par IP Address Subnet Mask Gateway TOP IP Port H5 232C Baud Rate bps 9600 19200 Data Bits e 7 C8 Parity Bit Even C Odd C None on
112. mation You must observe these precautions The following signal words and symbols are used in this manual Indicates a potentially hazardous situation which if not avoided will result in minor or moderate injury or may result in serious injury or death Additionally there may be significant property damage Indicates a potentially hazardous situation which if not avoided may result in minor N CAUTION or moderate injury or in property damage 1NaNnood SIHL aNVLSH3QaNn QV38 Missus e Meanings of Alert Symbols General Caution Indicates general cautionary warning or danger level information Electrical Shock Caution Indicates possibility of electric shock under specific conditions General Prohibition Indicates a general prohibition Disassembly Prohibition Indicates that disassembly is prohibited to prevent electric shock General Mandatory Action Indicates a general action that must be performed by the user Ensure to establish a solid grounding A label indicating that a device with a grounding terminal should always be grounded UHF RFID System User s Manual Introduction e Warnings NWARNING Never attempt to disassemble any Units while power is being supplied Doing so may result in serious electrical shock or electrocution Never touch any of the terminals while power is being supplied Doing so may result in serious electrical shock or electro
113. mporarily Disabled f the setting item is ft1 or ft2 the five items shall be specified with space separation between each item Instead of space enclosing double quotations is not allowable In a single command multiple setting items can be specified by separating with space 2 or more character spaces are acceptable for indicating separation SETC RC lt LF gt Response RC Response Code Example 1 When Antenna port 1 power 22 5 Gen2 session for Once Mode Reading 1 is specified Tx SETC pw1 22 5 ss1 1 lt LF gt Rx SETCOO00 lt LF gt Example 2 When Filter 1 or 2 Filter1 s Bank 1 Pointer 32 Length 2 Data CO 11b Filter2 s Bank 1 Pointer 64 Length 16 Data 125A 00010010 01011010b is specified Tx SETC ft1 0 1 32 2 CO lt LF gt Rx SETCOO00 LF Tx SETC ft2 0 1 64 16 125A lt LF gt Rx SETCOO00 LF Tx SETC fte 1 2 lt LF gt Rx SETCOO00 LF UHF RFID System User s Manual o m O T Dunes 115 SECTION 5 Command Line Interface B Get Communication GETC This command allows the reader to read the current communication conditions Just after SET Communication command SETC is executed new information shall be read out Command Format Command code SP Parameter 1 SP SP Parameter n GEJT C 4 1 n 1 1 n Item Description Referred Setting value and Setting item are specified Refer to the Funct
114. n claimed Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABIL 14 15 16 17 18 ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or oth erwise of any intellectual property right c Buyer Remedy Omron s sole obli gation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsi ble for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were prop erly handled stored installed and maintained and
115. n the elements Parameters and Options space has to be entered SP Space 20h 1 for one or more character Even if a two or more characters of space are put in they work same way as one character space Option 1 The code in which the option is shown is set Number of RF Tag 3 Number of RF Tags for communication commands ID or Data value The RF tag ID s or data read by the reader with Hex code If the reader reads n multiple tags IDs or data it indicates them in line with space s between each ID or data Data in hexadecimal numbers does not have 0x All hexadecimal numbers as commands and data in the read tags are indicated with upper case letters A to F UHF RFID System User s Manual SECTION 5 Command Line Interface Command Code List Executabl Comman e in Command Name Description d Code communic ation Communication Command to communicate with tags Read ID Heads ID data from the tag memory Write ID Writes ID data into the tag memory Read Data Reads data from the tag memory including passwords Write Data Writes data to the tag memory including passwords Lock Sets Lock function in the tag Disables the tag permanently 2 Setting Command to set a condition SETR Set Reader Sets the function settings in the reader GETR Get Reader Reads the function settings from reader SETO Set Communication Sets
116. ncrease the data trafic on the communiction I F on Ethernet or RS 232C Effect of each session flag None 500ms to 5000ms Same when tag is energized 2000ms or more Reference Class1 Generation2 UHF RFID Protocol for Communictions Version 1 1 0 SL flag which can be specified independetly with SO to S3 is used for filtering function UHF RFID System 46 User s Manual SECTION 3 Mode and Function LBT listen Before talk In the Japanese radio regulation it needs to check the available channels before it outputs the radio LBT Listen Before Talk due to its limited channl usage LBT requirements for high output Carrier sense level 74 dBm channel Carrier sense time above 5msec transmitting duration transimit below 4msec wait least 50msec It can select the transmitting channel either all channels or only specfied channels with LBT control The default setting is set to all channels 1 to 9 channel It can also specify 1 3 5 channels for example If you select only one channel and this channel is not available during timout period of the command the reader returns the communication error code 7000 channel are not available uonounJ UHF RFID System User s Manual 47 uonounJj 48 MEMO UHF RFID System User s Manual SECTION 4 Diagnosis and Maintenance Connection of Reader and each equipment 50 Ld Wiingtrcable 5 UHF RFID System User s
117. nd Line Interface Control Command Initialize setting INIT This command initializes all setting of reader to the factory default setting All settings shall be written into the inner nonvolatile memories After executing this INIT command the reader requires reboot E Command Format Command code E Response Format Response code ALARSA u 4 4 Description U m O T 0000 Normal end For other Response codes refer to Hesponse Code List I p 71 Response code E Command Response Example Initialize setting INIT pueululo 041u02 INIT lt LF gt INIT RC lt LF gt RC Response Code Example 1 All setting of reader is initialized to the factory default setting Tx INIT lt LF gt Rx INITOO00 LF UHF RFID System User s Manual 119 SECTION 5 Command Line Interface Stop the repeating operation STOP This command instructs the reader to stop the operation in process E Command Format Response Format Command code Response code Description 0000 Normal end For other Response codes refer to Response Code List I p 71 Response code m O T Command Response Example Initialize setting INIT STOP LF STOP RC LF RC Response Code 5 oJ1u02 The communication process is not run
118. nforming standard IEEE802 3 compliance 10Base T IEEE802 3u compliance 100Base TX Protocol TCP IP Port TCP IP Port 7090 HTTP Port 80 Cable length Marketed range B RS 232C Conforming standard RS 232C compliance Baud rate 9 600 bps 19 200 bps 38 400 bps 57 600 bps Data length 7 8 bits suoneouyioeds Stop bit 1 2 bit A The length of communication cable may influnces on maxium transmission rate Please check before operation gt UHF RFID System User s Manual 31 SECTION 2 Specifications and Performance Gen2 Tags Memory Map Gen2 Tags Memory Map GEN tags have four memory banks Kill Password and Access Password are stored in bank 00 Reserved Area EPC code is in bank 01 EPC Area Tag Identification Memory data that is read only is in bank 10 TID Area User data is in m bank 11 User Area For the detailed information refer each tag s specification MSB LSB 9 27 1F0h IPFO Memory Bank3 Bank 11 5Fh 4 2Fh 0 1Fh OFh 3 Memory Bank2 3Fh 5 Bank 10 Tag and Vender Specified Data ex Tag Serial Number 2Fh Tag Identification Memory data 1Fh Tag Identification Memory data OFh Memory Bank Bank 01 EPC 15 0 10Fh EPC 31 16 FFh EPC 47 32 EFh EPC 63 48 DFh EPC 239 224 2Fh PC Protocol Control SeeNote 1 1Fh Memory ES CRC
119. ning in the reader the error is returned Code 1500 Example 1 When the reader stops multi repeat communication Tx RDID seq MRP ant 12 Read ID command is started under multi repeat mode Tx STOP lt LF gt Rx STOP0000 lt LF gt UHF RFID System 120 User s Manual SECTION 5 Command Line Interface Reset RSET This command reboots the reader after the reader returns the response that the command has received When it is connected via Ethernet it is disconnect the network connection before rebooting E Command Format Command code R E s r 4 E Response Format Command code R E s r Response code 4 Item Description 0000 Normal end Response code For other Response codes refer to Hesponse Code List 71 E Command Response Example Initialize setting INIT Command Response REST lt LF gt REST RC lt LF gt RC Response Code Example 1 Reboot the reader Tx REST lt LF gt Rx RESTOO00 LF UHF RFID System User s Manual S NOILOAS pueululo 041u02 121 SECTION 5 Command Line Interface External Input Output control EXIO This command allows the reader to output ON OFF to the output terminal and read an input terminal status If output port s is connected to the device s that is not used for general purpose the reader ignores ON OFF output for the port s If output setting value is omitted the read
120. not subject to contamina tion abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Compa nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environ ments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted Indemnities Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities losses claims costs and expenses including attorney s fees and expenses related to any claim inves tigation litigation or proceeding whether or not Omron is a party which arises or is alleged to arise from Buyers acts or omissions under these Terms or
121. o changing communication speed with RF tag such as high speed communication or reducing speed to get more reliably communcation The communication mode can be specified by comunication setting parameter SETC When the communiction mode is set to MODE 0 it represents AUTO MODE that the reader automtically change the communication speed according to the environmental interferences level When using MODE 2 which provides the highest communication speed intereferences between several readers will be increased and cause to deteriorate the read performance Abnormality HF Tag Reader Writer Auto 40kbps 160kbps Communication speed Reader Writer gt RF Tag 40kbps Note MODE 0 is default setting 0 is default setting QW Please test prior to operation to check the influences on interferences with several readers if you change the 4 communication speed fast UHF RFID System 36 User s Manual SECTION 3 Mode and Function Function The reader consists of there parts of function System I F function for communication with host system or controlling general input and output from external devices control the reader device and control the communication with RF tag As a function of controlling the reader device it includes Command execution Self execution firmware update V750 Reader Writer P P computer System I F Function Reader Control Function RF Tag Command I F Func
122. on Factory setting Response Interface Initial Executed Command It specifies make a response after the registration command is executed replying ahead 0 None 1 Ethernet 2 RS 232C Format Function S Commana S Spase code Function One digit 0 unregistered 1 execute command Command Command to be execute ex HDID seq SOC tmo 500 Max 255 characters ASCII Note This setting value has double quotation marks 1 Ethernet Command Entry Input port 1 function setting Format Function S Timing S Command Function One digit 0 None 1 Command execution Timing One digit 0 Startup Fixed Command Command to be execute ex RDID seq SOC tmo 500 Max 255 characters ASCII Note This setting value has double quotation marks Note Only when the Function is specified with 1 set the Timing and the Command When the Function is specified with 0 executed Command data is saved and response data is returned Input port 2 function setting Same as IN1 Input port 3 function setting Same as IN1 Input port 4 function setting UHF RFID System User s Manual Same as IN1 SECTION 5 Command Line Interface Programmable Output Output port 1 function setting Output port 2 function setting Output port 3 function setting Output port 4 function setting Format Timing S OutputTime S Condition Timing
123. on or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases but the following is a non exhaustive list of applications for which particular attention must be given i Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document ii Use in consumer products or any use in significant quantities iii Energy control systems combustion systems railroad systems aviation systems medical equipment amusement machines vehicles safety equip ment and installations subject to separate industry or government regulations iv Systems machines and equipment that could present a risk to life or prop erty Please know and observe all prohibitions of use applicable to this Prod uct NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON S PRODUCT IS PROP ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other
124. one of the target tag Communication During the transaction after tag detection communication error or error process time out has occurred and consequently the transaction can TRE not be completed normally In the case of ID write Data write a part of data in the tag may have been written 7i 00 Verification error The reader has not written the data to the tag by reason of verification error RF Tag Address Specifying Bank Address in the tag memory is incorrect and command communica 7A 00 men specification error can not be executed error 7B 00 Data write error During the data write into the detected tag sufficient power is not supplied to the tag 1X Antenna derection At the R W starts up an appropriate antenna has not been connected to See Note error the specified antenna port 2X Antenna error Error occurred with the antenna connected to the specified antenna port See Note even though the antenna is detected normally when start up Lock error When data write or read command is sent for the locked area It depends on the tag s chip specifications For Monza chip when these 7E 00 commands are sent for Lock Bit of User Memory because this area does not exist See Note2 OX Tag error The tag has been rejected the command process See Note1 An error that blocks command execution has been detected in the System XX eu 9A ee System error hardware such as malfunction of inner cir
125. oting the reader Up to 65535 error number can be counted epojiy uondo UHF RFID System User s Manual 14 apo uondo 142 SECTION 6 Browser Based Interface B Noise Check Click to open latest omnon erg r 1 Latest Error Noise Check Error History 1 Updating Select antenna number Click to stop Click to change options to be monitored Click to open error log The level to detected as occupied 2 channel by carrier sense 21 22 31 32 41 42 49 50 Frequency Channel 1 Status Indicator Area 2 Channel monitor The field strength of each channels are shonw in bar graph To start the monitroing the chanel choose the antenna number and click the Start button The field strength is updating in real time Click the Stop button to stop monitoring The line in the graph indicates the level for Carrier Sense which uses to check the availablity of channel If the field strength is below this level the channel is available Use this level as refernce only UHF RFID System User s Manual SECTION 6 Browser Based Interface Option information OMRON Reader Settings Comm Settings Operation Settings Click to open latest Comm Test Status Option information 1 to be displayed Click to open 1 Option No 1 channel monitor 2 Option Name u Chip Hibiki V1 34 Support Click
126. pecifies error codes for comparison in series Max 6 error code can be specified ex 7071 see If there is no condition to be set the output signal shall be on after normal Ex When communication error Error code is 70xx or verify error Error code is 71xx has been occurred DAT 7071 UHF RFID System 108 User s Manual SECTION 5 Command Line Interface Set Operation SETO This command is to write operation conditions into the nonvolatile memories in the reader The new setting shall be enabled at the upcoming startup Command Format Command code SP Parameter n Description Setting item Setting value 3 1 n Setting value is connected by the equal sign and specified the set item Refer to the Operation Setting for details of setting item 106 Response Format Command code Response code Description 0000 Normal end For other Response codes refer to Response Code List 71 Response code UHF RFID System User s Manual U m O T pueuiuio Dunes 109 SECTION 5 Command Line Interface Command Response Example oet Operation SETO SETO S param value lt LF gt S Space code param Setting item is specified by the sign value Setting value is connected by equal sign and specified SETO RC LF Response RC Response Code Example 1 When the Response I F after
127. port number over 1024 can be changed by using a setting command or Web page If the reader can not detect the DHCP server under dynamic IP address setting it will flash the error indicator and start up with static IP address RS 232C To connect to the PC or PLC Programmable Logic Controller which equipped RS 232C serial communiction I F Following communication setting for RS 232C are supported Opptional communication conditions Baud rate 9 600 bps 19 200 bps 38 400 bps 57 600 bps 57 600 bps Data length 7 8 bits 7 bit Parity Even Odd None Even Stop bit 1 2 bit 2 bit uonounJ UHF RFID System 38 User s Manual B Web Browser Function SECTION 3 Mode and Function All the reader function can be accessed thorough the web browser which is installded on the standard PC It can open the operation windows by inputting the address http 192 168 1 200 default If you are setting individual IP address for each readers you need to input its IP address The Java software required to control the web browser I F alo Refer to the Browser Based Interface for details CHECK UR p 129 OMRON Reader Settings Comm Settings Operation Settings Comm Test Utility Reader Status Reset System uonounJj Product Type V750 BA50C04 US Firmware Version 101 101 102 0 Serial Number 0000000 MAC Address 00 00 0A 89 03 5B Valid Antenna s 1234 Operation Status Ready TCP I
128. r of antenna operation with figure 1 4 max 9 characters The figure 1 to 4 is antenna s identical number Number of antenna 0 or from 10 to 2550 in 10msec increments in DRM off p rocess time out msec 0 or from 10 to 10000 in 10msec increments in DRM on Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail ILA p 73 Specifies a password with 8 digit hex number 32 bit word It is essential unless the value in the area of tag Access Password is zero Access password E Response Format d d Command code Response code SP Tag count SP TIF information Item Description 0000 Normal end For other Response codes refer to Hesponse Code List US p 71 Response code Tag count Count of written tag s Tif information specified with command TIF information Mt MAU Each optional value for tif information lines with comma separation L1 Secure function is supported by certificication number at 001AHB1004 001PVAB1002 The reader which certification number is 001AHB1001 can not use this function Also Secure function can only use for the RF tags which supports secure RFID protocol The standard EPC global Class1 Generation 2 RF tags does not work UHF RFID System User s Manual U m O
129. r shall be responsible for and shall bear all costs involved in obtaining any government approvals required for the impor tation or sale of the Products Taxes All taxes duties and other governmental charges other than general real property and income taxes including any interest or penalties thereon imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture production sale delivery importa tion consumption or use of the Products sold hereunder including customs duties and sales excise use turnover and license taxes shall be charged to and remitted by Buyer to Omron Financial If the financial position of Buyer at any time becomes unsatisfactory to Omron Omron reserves the right to stop shipments or require satisfactory security or payment in advance If Buyer fails to make payment or otherwise comply with these Terms or any related agreement Omron may without liabil ity and in addition to other remedies cancel any unshipped portion of Prod ucts sold hereunder and stop any Products in transit until Buyer pays all amounts including amounts payable hereunder whether or not then due which are owing to it by Buyer Buyer shall in any event remain liable for all unpaid accounts Cancellation Etc Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses Force Majeure Omron shall no
130. ration Mode Baud Rate bps 57600 Data Bits T Parity Bit E Stop Bitis 2 UHF RFID System User s Manual 145 SECTION 6 Browser Based Interface Description of Each Item Reader Status Item Description Note Product Type Type name of the productV750 BA50C04 US Firmware Version Firmware version currently installed in the Only the factory default first number is displayed reader 100 100 100 0 Serial Number Unique number for product set in the factory MAC Address The reader s MAC address Ethernet Settings Operation Mode Item Description Host Name Used to refer the host in the network Domain Name Name of network domain in the reader runs DHCP Whether the reader uses DHCP server or not IP Address The reader s IP address in the network Subnet Mask The reader s subnet mask in the network Gateway The reader s gateway address in the network TCP IP Port Port number for command interface via Ethernet e RS 232C Settings Operation Mode Item Description Baud Rate bps Baud rate bps o m O Data Data bit length Parity Bit Parity bit Stop Bit s Count of stop bit Spo aes Action Reset System To restart the system press Reset System button After displaying message Accept RESET Reboot in one second After resetting the reader you can access the browser by clicking Reload button or opening another browser page
131. re you use the reader 4 Instruction sheet for accessories Check all accessories included decribed on this instruction sheet when you open the box firstly A10sseooy UHF RFID System 160 User s Manual SECTION 9 Appendices Degree of Protection Ingress protection degrees I are determined by the following tests Be sure to check the sealing capa bility under the actual operating environment and conditions before actual use IP indicates the ingress protection symbol B International Electrotechnical Commission Standards IEC 60529 1989 11 IP 7 B A A First Digit Degree of Protection from Solid Materials No protection Protects against penetration of any solid object such as a hand that is 50 mm or more in diameter Protects against penetration of any solid object such as a finger that is 12 5 mm or more in diame ter Protects against penetration of any solid object such as a wire that is 2 5 mm or more in diameter Protects against penetration of any solid object such as a wire that is 1 mm or more in diameter Protects against penetration of dust of a quantity that may cause malfunction or obstruct the safe operation of the product Protects against penetration of all dust Protection Test method with pure water io No protection Not protected against water No test Protects against vertical drops Water is dropped vertically towards the produc
132. read 20 tag EPC 96bit is measured It calculates by the calculating formula after that Communications Time Detection Multi ID Read Mode1 RF Tag Reader Writer 40kbps Pa It becomes the time between Mode1 and mode 2 for ModeO Auto Communication Time ms 10 20 30 40 50 Number of Tags The baud rate for ModeO Auto mode is decided by the interference situation between two or more Reader Writer The baud rate in the state without interference completely becomes 160kbps RF Tag Reader Writer UHF RFID System 154 User s Manual SECTION 8 Reference data Single ID Read Write E Measurement condition at Communication Time environment Anechoic Chamber Distance 0 5 m fixation Distance between antenna and tag Condition Communication time required to read 20 tag EPC 96bit is measured Table of Communication Time Mode Single ID Read Single ID Write 1 40kbps 13msec 108msec Mode 160kbps Omsec 86msec suoneoiunuinuoo UHF RFID System User s Manual 155 SECTION 8 Reference data Multi Data Read Following charts shows the standard at the communication time of multi data read added with firmware version 105 106 105 0 or later E Measurement condition at Communication Time environment Anechoic Chamber Distance 0 5 m fixation Distance between antenna and tag Condition Communication time required to data read
133. ror results or judgement results based on comparison the response from the RF tag data It can use from both command I F or web browzer I F Available conditions RUN Running Normally Same action as RUN LED except for blink ERR Abnormally stopped Same action as ERR LED except for blink COM Communication status Same action as OR of AT1 4 LED ATn n 1 to 4 Antenna n is specified Same action as LED of AT1 AT2 AT3 and AT4 The judgement results output to output port OUT1 to OUT4 according to the judgement criteria which registered in the reader at the timing when the RF tag is responeded It can be specified two judgment criteria and output duration for each output In case of no judgement criteria setting it alwasy output Available conditions Output timing Condition setting NORMAL The process is The read written tag count Output duration finished normally Operator gt lt Compared number Data comparison Operator Compared data ERROR The process is Error code Output duration finished abnormally t Refer to the Command Line Interface and Browser Based Interface for details of a Setting method i IL p 59 p 129 B Firmware Update You can update the firmware by specifying update files via Web browser Updated data shall be effective upon subsequent powering up If the firmware update is failed with some reasons and the reader could not boot up corr
134. rs applications 1 Selective communication modes for various applications Single access mode reads a tag in high speed if there is a single tag in the communication field Multi access mode optimizes a sequence automatically according to the number of tags existing in the communication field 2 Various communication condition setting Multiple communication conditions suit user s optional usage Low power High power Low iid 3 Self operation function Using two function command entry function and programmable output function the reader can implement simple judgment or processing without instruction from the host Command entry Can set a command so that the command starts when power is turned on or input terminal signal Is Programmable output 4 outputs can be used for output terminals to show reader status or communication results When the output terminal is used for communication results the result conditions can be set by choosing criteria objective such as data value or tag count PC Data collection HB Ethernet 2 UHF RFID System User s Manual SECTION 1 Features and System Configuration 2 Rich maintenance functions and on site verification functions 1 Monitoring and setting via Web browser Via Web browser you can get an operation status or setting conditions and set the operation parameters easily o m O
135. s may generate noise which cause radio interference and may affect communication with Tags If the product is required in the vicinity of these items check for any interferences prior to use Observe the following precautions to minimize the effects of normal noise 1 Ground the ground terminal on the Product and all metal objects in the vicinity of the Product to 100 Q or less 2 Do not use the Product near high voltage or high current lines 16 Do not allow the device or cables to be exposed to water Doing so may result in electric shock fire or failure of non waterproof devices or cables 17 Do not use damaged cables Continued use of the damaged cables may result in electric shock or fire 18 It is not possible to connect it with Reader Writer excluding the specified antenna 19 Be sure that all the mounting screws terminal screws and cable connector screws are tightened to the torque specified in the relevant manuals Incorrect tightening torque may result in malfunction UHF RFID System User s Manual Introduction Storage Do not store the Product in the following locations Locations exposed to corrosive gases dust metallic powder or salts Locations not within the specified operating temperature range Locations subject to rapid changes in temperature or condensation Locations not within the specified storage humidity range Locations subject to direct vibration or shock outside the specified ranges Locat
136. s that assist you to operate it usefully E Latest Error Logging Om Firmware Update Click to open error log id LN Latest Error Loaain gg g Error History aq E 8 Stop J Ems Click to stop 18 Click to open channel monitor 1 Status Indicator Area 2 Latest Error log Error log Command Code and Termination Code are shown which errors occur after booting up the reader Up to 32 latest error logs are shown Click the Start button to refresh the error log To stop refreshing click Stop button The error are updating in real time until it stop the logging The error log can be cleared by resetting or rebooting the reader UHF RFID System User s Manual SECTION 6 Browser Based Interface B History of Error Logging Click to open latest error log Error Code 10 Parity 11 Framing Verify 12 OverRun Address 13 FCS Write 14 Command Antenna 15 Status Lock 18 Frame Tag System 1 Status Indicator Area 2 Number of error time The total number of error after booting the reader are shown The number of the command execution are shonw in above column The number of errors are shown in each kinds of errors Upper two digits of Termination code Click the Start button to refresh the error log To stop refreshing click Stop button The error are updating in real time until it stop the logging The error log can be cleared by resetting or rebo
137. sensor that works as a produced by PHOENIX Ethernet port OUT 1 2 3 4 C trigger signal for communication start 4 Outputs connects with the light or CONTACT actuator that is driven by output signal Mode switch Pushing this button for 1 second or more makes the system rebooting with Not indicated default setting which will be functional in case of system error or setting unknown Status Indicators PWR RUN ERR NORM ERC ANTENNA PWR RUN ERR NORM ERC Note The high speed mode cannot be used by the controller s setting Uu Antennas other than V740 HS01CA HSO1LA cannot be connected e The antenna cable must use an optional special antenna cable The AC adaptor must use the AC adaptor of the attachment CHECK The external I O connector must use the terminal stand plug of the attachment UHF RFID System 20 User s Manual SECTION 2 Specifications and Performance Connectors Pin number for each connectors represents its pin allocation from the external view of the reader 1 Antenna Port The antenna port is used to connect the antenna cable B Connector Reverse TNC ANT1 ANT2 ANT3 o Name Function 6 Se Signal output SG GND Ground 2 RS 232C Interface This port is used to connect the reader to the host containing RS 232C interface such as PC or PLC Programmable logic controller If you use the PC as a host prepare a
138. served Mem size Each area memory size EPC Mem size Unit word TID Mem size User Mem size Attenuate level of tag ATT Level TT Level specified with Set Attenuate level command Represents lock status of each bank with bit Description User memory Pwd read Perma lock TID memory Pwd read Perma lock memory Pwd read Perma lock Access pwd Pwd R W Bank Lock Perma lock User memory Pwd write Perma lock TID memory Pwd write Perma lock UII memory Pwd write 10 spueuiuioo 2 Perma lock Kill pwd Pwd R W Perma lock Values are specified by Lock or Read Lock command UHF RFID System User s Manual 97 SECTION 5 Command Line Interface Item Description Represents lock status of each block with bit Bit Description 7 U5 Pass User Pwd read Perma lock 0 1 UA Pass User Pwd read Perma lock U3 Pass User Pwd read Perma lock U2 Pass User Pwd read Perma lock U1 Pass User Pwd read Perma lock Block Read Lock Values are specified by Block Read Lock command Represents lock status of password for each block with bit Bit Description 1 6 RFU 7 U5 Pass Pwd R W m O T Perma lock U4 Pass Pwd R W Perma lock U2 Pass Pwd R W Perma lock U1 Pass Pwd R W
139. ses corrosive gasses dust metallic powder or salts Tighten the Backplane mounting screws and terminal block screws securely If any cable has a locking mechanism make sure that it has been locked before using the cable Do not apply voltages to the input terminals in excess of the rated input voltage Do not allow water or wires to enter the Product through gaps in the case Otherwise fire or electric shock may Occur Turn OFF the power to the Product before attaching or removing an Antenna 7 Ifan error is detected in the Product immediately stop operation and turn OFF the power supply Consult with an OMRON representative 8 Dispose of the Product as industrial waste 9 Observe all warnings and precautions given in the body of this manual GU goce qu INAWNOO d SIHL GNVLSYSGNN QV38 UHF RFID System User s Manual INAWNOOd SIHL GNVLSHUAGNN QV38 Introduction Precautions for Correct Use Always observe the following precautions to prevent operation failure malfunctions and adverse effects on performance and equipment 1 Do not use non waterproof Products in an environment where mist is present For Reader Writer and normal type Antennas 2 Do not expose the Products to chemicals that adversely affect the Product materials 3 The transmission distance will be reduced if the front and back panels are mistakenly reversed and the Unit is mounted to a metallic surface 4 The transmiss
140. sponse 4 4 ltem Description o 0000 Normal end m Response code For other Response codes refer to Response Code List jt 71 Response data The response data that replies immediately before is set immediately before a Command Response Example S Request Resend RRES RRES lt LF gt Response The latest response If there is no the latest response data the error is returned Code 1500 When the communication mode is SRP MRP it can be accepted But if the timeout value is so small that the reader may not identify various responses returned continuously Example 1 When the host requests to resend the response for the successful single ID read command RDID seq SOC ant 1 tif EPC ANT that has been executed most lately Tx RRES lt LF gt Rx RDIDOO00 001 FFFFEEEEDDDDGCE2BBBB10738 1 LF UHF RFID System User s Manual 125 SECTION 5 Command Line Interface Test System TEST This command instructs the reader to return the reader status data and the exact data message just after receiving it from the host It is to test a communication line and to get reader status E Command Format Test data n Test Data The test data that turns is set E Response Format Response code SP Reader Status SP Test Data Description m O T 0
141. st 71 Response code Tag count Count of written tag s Tif information specified with command TIF information MAN Each optional value for tif information lines with comma separation Secure function is supported by certificication number at 001AHB1004 001 1002 The reader which certification amp number is 001AHB1001 can not use this function Also Secure function can only use for the RF tags which supports Secure RFID protocol The standard EPC global Class Generation 2 RF tags does not work UHF RFID System User s Manual SECTION 5 Command Line Interface Setting Command To set the Reader Status and Reader Settings following items shall be specified in the SET Reader command SETR and GET Reader command GETR The Reader Status is available only for reading data Function condition setting of Reader Writer Parameter that can be specified by GETR Peculiar information on Reader Connected state of Antenna Elapsed time Name Description Fixe Value Manufacturer Manufacturer name is read OMRON Corporation Type of the reader Product form is read V750 BA50C04 US XXX XXX XXX X SH MB FP CA Hardware level Serial number Production number is read MAC address MAC address is read 00 00 0A 89 XX XX Antenna status The number of the connected antenna is read Connected Antenna ex Antenna 1 Anntena 3 and Antenna 4 ar
142. sword 31 16 OFh FACTORY SETTINGS Note 2 Data Pointer and Data length in the Data Read RDDT Data Write WTDT command format should be specified by Decimal Number in each WORD 16bits unit EPC 15 0 EPC 31 16 N A A EPC 47 32 Eee Sea Protocol Control 0 CRC 16 Data Pointer In case data reading 32bits 2WORD data on EPC 95 to 64bits in the above me RDDT 1 2 2 Memory Bank 1 Data Pointa 2 Data length 2 UHF RFID System User s Manual dey Aioway 33 SECTION 2 Specifications and Performance Memory Map of the Secure Tag Following table shows the memory map of the secure tag u HIBIKI Ver1 34 MSB LSB Block5 User 255 240 50Fh Block4 User 15 0 4FFh 400h Block4 User 255 240 40Fh 3FFh Memory Bank 3 Dg Bank 11 Block3 User 255 240 30Fh USER memory Block2 User 15 0 2FFh 96word Dd 200 Block2 User 255 240 20Fh 1FFh Block1 User 255 240 10Fh BlockO User 15 0 OFFh dey Memory Bank 2 ode Bank 10 030h TID memory 020h 02Fh 4word 010h 01Fh 000h OOFh Memory Bank 1 Bank 01 EPC memory 040h EPC 207 192 04Fh 17word 030h EPC 223 208 03Fh 020h EPC 23
143. t Rx WTIDOOOO 001 1 lt LF gt If the tag had no EPC data before is returned Example 4 When FFFFFFFFFFFFFFFFFFFFFFFF 2 and 300 are specified for ID antenna timeout and the command is executed but no tag is found Tx WTID FFFFFFFFFFFFFFFFFFFFFFFF ant 2 tmo 300 lt LF gt Rx WTIDOO00 000 lt LF gt Example 5 When 123412341 234123412341234 and ABCDABCD are specified for ID and access password is executed but access password is not matched Tx WTID 12341234 12341234 12341234 owd ABCDABCD LF Rx WTIDOO00 000 LF Example 6 When an error has occurred during communication process Tx WTID 1234567890ABCDEF12345678 LF Rx WTID7012 lt LF gt The error code Code 7012 is returned UHF RFID System User s Manual 79 SECTION 5 Command Line Interface Read Data RDDT E Command Format Command code SP Memory Bank SP Data Pointer SP Data Length SP Option 1 SP SP Option n 4 1 1 1 1to3 1 10r2 1 n 1 1 n Parameter Description Specifies memory bank of Gen2 tag 0 Reserved Area Memory bank 1 EPC Area 2 TID Area 3 User Area Specifies memory address intended to access in the memory bank 0 255 Specifies hexadecimal number in word 16 bits increments 1 32 Option code Available Optional Value SOC Single Once SRP Single Repeat MOC Multi Once MRP Multi Repeat Number of antenna Specifies order of antenna operation with
144. t be liable for any delay or failure in delivery resulting from causes beyond its control including earthquakes fires floods strikes or other labor disputes shortage of labor or materials accidents to machinery acts of sabotage riots delay in or lack of transportation or the requirements of any government authority Shipping Delivery Unless otherwise expressly agreed in writing by Omron a Shipments shall be by a carrier selected by Omron Omron will not drop ship except in break down situations b Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer All sales and shipments of Products shall be FOB shipping point unless oth erwise stated in writing by Omron at which point title and risk of loss shall pass from Omron to Buyer provided that Omron shall retain a security inter est in the Products until the full purchase price is paid d Delivery and shipping dates are estimates only and e Omron will package Products as it deems proper for protection against nor mal handling and extra charges apply to special conditions Claims Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original trans portation bill signed by the carrier noting that the carrier received the Products from Omron in the conditio
145. t from of water towards the product the test machine for 10 min uonoojoJdg Protects against drops Water is dropped for 2 5 min each i e 10 min in total water approaching at a maxi towards the product inclined 15 to the left right back mum angle of 15 Lito the left and front from the test machine right back and front from ver tical towards the product UHF RFID System User s Manual 161 uonoojo4d 162 9 Appendices Protection Test method with pure water Protection against sprin Protects against sprinkled Water is sprinkled for 10 min at a maximum angle of kled water water approaching at a maxi 60 to the left and right from vertical from the test mum angle of 60 from verti machine ey Water rate is 0 07 cal towards the product Protection against water Protects against water spray Water is sprayed at any angle towards the product for approaching at any angle 10 min from the test machine towards the product pee tal ur liter min per hole On Protection against water jet Protects against water jet Water is jet sorayed at any angle towards the product spray spray approaching at any for 1 min per square meter for at least 3 min in total angle towards the product from the test machine 12 5 liter min 2 5to3m Discharging nozzle 6 3 dia Protection against high Protects against h
146. t lights for 50ms Antenna port 3 Antenna Port Communication process is running via antenna 3 When connecting with an antenna via antenna 3 is detected after power turns on it lights for 50ms Antenna port 4 Communication process is running via antenna 4 When connecting with an antenna via antenna 4 is detected after power turns on it lights for 50ms Input port 1 Signal of input port 1 is on Input port 2 Input port 3 Signal of input port 2 is on Signal of input port 3 is on Input Port Input port 4 Signal of input port 4 is on Output port 1 Output port 2 Signal of output port 1 is on Signal of output port 2 is on Output port 3 Signal of output port 3 is on Output Port Output port 4 Short interval approx 500ms cycle On 250ms Off 250ms Long interval approx 3000ms cycle On 1500ms Off 1500ms Signal of output port 4 is on UHF RFID System User s Manual 23 SECTION 2 Specifications and Performance Demensions V750 BA50C04 US Unit mm I 152 4 6 inch E AC Adapter Unit mm 12841 UHF RFID System 24 User s Manual SECTION 2 Specifications and Performance Antenna Name of each part B V 40 HS01CA V740 HS01LA CUUS UY FANCIES Mounting Hole SS 22 The number Mounting Hole is about surrounding four N Female conne
147. tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail I p 73 m O T E Response Format Command code Response code SP Tag count SP and TIF information 4 4 1 3 1 n Item Description 0000 Normal end For other Response codes refer to Hesponse Code List 71 Tag count Count of read tag s Response code System information of the read tags refer to following page in detail and Tif information specified with command Each optional value for tif information lines with comma separation System information and TIF information 10 spueuiuioo 2 UHF RFID System 96 User s Manual SECTION 5 Command Line Interface System Information Data Format Information Flag Reserved EPC TID USER ATT Level Bank Lock Bank Lock Bank Lock Bank Lock Mem size Mem size Mem size Mem size Read R W R W 4 2 2 2 2 2 4 4 4 4 Item Description Specifies a lock type of an password memory area intended to be controlled with double digits code shown as below Reserved Mem size 2 EPC Mem size 3 TID Mem size omania BE dan 5 ATT Level 0 1 Bank Lock Block Read Lock Block Password Read Write Lock Block Write Lock o m O T He
148. the code that indicates option type Defaul Code Item Specified Value EU Value Communication Specifies the communication sequence according to the operating conditions For only sequence Read ID command all parameters can be specified For other commands only SOC can be specified SOC Single Once SRP Single Repeat MOC Multi Once MRP Multi Repeat Antenna ID Can specify the order of antenna to operate from 1st to 9th with figure of 1 2 3 and 4 The figure 1 to 4 means antenna s identical number If an antenna is specified multiply the antenna executes sequence multiply depend on the order Format X XXXXXXXXX Max 9 characters X 1to4 Timeout Specifies time parameter for communication process in millisecond The numbers after rounding down to the 10 is added milliseconds as a specified value the least significant digit is always 0 If the communication sequence is SOC the specified value is the communication time If the value is specified O zero communication process will continue until STOP command is executed If the communication sequence is SRP MOC the specified value is maximum time between response 0 can t be specified on SHP MOC MRP sequence When you determine the value of Timeout see the section 5 2 Communication Time Min Oms Max 2550ms in DRM off or in firmware version 100 100 100 0 10000ms in DRM on and in firmware version 101 101 102 0 or later Step 10ms o m O
149. the communication settings in the reader temporary setting GETO Get Communication Reads the communication settings from the reader Set Reader Operation Sets the operation settings in the reader Get Reader Operation Reads the operation settings from reader U m O T SAVE Save communication Save the communication condition into the nonvolatile memories in the settings reader permanent setting 3 Control command to control the action Initialize Initializes all settings in the reader Stop Stops the communication with the RF Tags External Input Output Eeads input output port status control Set condition of output port Reset Restarts the reader Good Bye Disconnects the Ethernet connection Request Resend Requests to resend the last response data Test System Tests the communication between host and the reader Reads the operation status from reader ewo esuodseg pueuiuio Noise monitoring Monitors noise level of the specified antenna 4 Undefined command in the response frame only ICMD Illegal Command Vommand code to be used in the response frame if the R W receives undefined command UHF RFID System User s Manual 69 o m O T ewo 4 esuodseg pueuiuio 70 SECTION 5 Command Line Interface Exclusive commands for secure tag Following decribed Secure RFID protocol command Secure function command Secure function command can be us
150. tion IMPORTANT USER INFORMATION This equipment complies with FCC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency RF Exposure Guidelines in Supplement C to OET65 This equipment should be installed and operated with at least 23cm 9 1in and more between the radiator and person s body excluding extremities hands wrists feet and legs This device complies with RSS Gen of IC Rules Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of this device INAWNOOd SIHL aNVLSH3QNR QV38 2 Safety UL 60950 Can CSA C22 2 No 60950 IMPORTANT USER INFORMATION 1 For products numbered with 0001X06 to 0048X06 only AC adapter complies with UL 60950 For products numbered with 0049X06 or later AC adapter and the V750 Reader Writer comply with UL 60950 2 Products numbered with 0341308 or later comply with COFETEL certification 3 Product number consists of following data of seven digits AAAA B CC AAAA Serial number 0001 to 9999 except for specially specified product B Month 1 to 9 X Y and Z X210 Y 11 Z 12 CC Year UHF RFID System 6 User s Manual Introduction Precautions for Safe Use Be sure to observe the following precautions to ensure safe use of the Product 1 Locations exposed to any flammable gas
151. tion Command Execution Communication command 1 Ethernet 1 Communication command Communication Mode 2 RS 232C Single Multi access 2 Reader control command Q Web Browser Function Reader control command Ethernet 3 Maintenance command Reader Writer Setting Communication condition Setting Digital Input Output Self Operation Maintenance command It reads or changes operation control or setting of the reader External Input Output control Firmware Update uonounJ System I F Function The System I F provides the command I F for communication with host system and web browser I F It also provides digital input output I F for controlling external input and output devices Command I F Function Via 10 100BaseT Ethernet or RS 232C the host issues a command to control the reader As the control method V750 supports original procedures Same commands are used via Ethernet and RS 232C RS 232C Cable Ethernet Cable PLO UHF RFID System User s Manual SECTION 3 Mode and Function e Ethernet Ethernet is connected with the host such as server computer via TCP IP protocol IP address corresponds to dynamic IP address assigned by DHCP server You can choose the static IP address Default 192 168 1 200 or a dynamic IP address Default setting is static IP address The port 7090 is used by reader for communication IP address and the
152. tion with RF tags comes from various causes Refer the following items and check the environmental condition 1 Mutul interferences on the readers If multiple readers are installed the mutual interferences occurs between those readers To avoid the interferences firstly it is effective not to transmitt and communicate at the same time If it needs to trasmitt and communicate at the same time adjust the output power level not to output unwanted level or carefully select the channel to be transmitted not to allocated closely tgo minimize the inteferences 2 Antenna installation The communication range for Circular poralization antenna Model V740 HS01CA and Linear poralization antenna Model V740 HS01L 4A are slightly different Check the communication range and install the antenna and RF tag position within this range to have enugh margin 9 5 S101134 FANCIES 3 The reader settings The settings of the reader which may influences communication performance are below Please carefully specify the command option Communication Sequence single once single repeat multi once multi repeat timeout value communication duration 100 to 5000 msec range e antenna number the antenna order for transmiting Sesson flag Duration for keeping power on reset for RF tag UHF RFID System User s Manual 14 SECTION 7 Troubleshooting Alarms and Errors 4 Condition of the RF tag installation materi
153. to mode Dunes Filtering Filtering enable 0 None 1 Filter1 only 2 Filter2 only 1 amp 2 Filter1 and Filter2 1 2 Filter1 or Filter2 Filtering bondition 1 FT2 Filtering bondition 1 Format FileterType S MemBank S Pointer S Length S Value FilterType O fixed MemBank 0 to 3 Pointer O to 9999 bit 1 Length 1 to 255 bit Value XXXX Set longer bits than the bits specified in the Length with 2 digit hexadecimal number 0 to F Max 64 characters The most significant bit is a Pointer of the Value Same as FT1 None omoothing Prevents repeat read Smoothing buffer size ONR Omit no tag response Buffer Size is set 0 Disable 1 to 999 Enable Buffer Size 0 Disable 1 Enable 0 Disable 0 Disable 1 In firmware versions earlier than 103 104 103 0 the programmable range is 0 to 255 bit UHF RFID System User s Manual 113 SECTION 5 Command Line Interface Set Communication SETC This command writes the communication settings in the reader While the command is being executed setting conditions in the reader are changed To write the setting data into the nonvolatile memories in the reader SAVE command SAVE shall be executed The new setting shall be enabled at the upcoming startup Command Format i Command code S C Parameter 1 SP SP Parameter v 4 1 n 1 1 n
154. to open error log IS a secure function corresponding to u Chip It 1 34 Support is provided for the firmware version 103 103 104 0 or later 1 Option No To display the information of available options select Option No 2 Option Name To display the information of available options select Option Name 3 Option information To displya the information of options The contents shown in this option depends on the option UHF RFID System User s Manual apo uondo 143 SECTION 6 Browser Based Interface Firmware Update Status Page Click to open status windows OMRON Firmware Update Specify the location of firemware sess egen sees 000000000 000000000 000000000 000000000 P500008 00 0000 105 S00 000 108 00000 C02 SEER CS EEE PS E28 E222 222222222 P o click to start the firmware update OMRON Status Pug Firmware Update File Transfer SUCCEEDED Start Update Mode Update Started Compatibility Check OK Update Phase 1 OK Update Phase OK Update Phase 3 OK Update Phase 4 OK All Finished System Resets Automatically epojiy uondo To update the firmware select the reader firmware file on the reference button and click the update When the update starts the antenna indicator on top of the reader turns on and IN OUT indicator turns step by step to represents the progress of update In the
155. ts Option code Available Optional Value seq Communication sequence SOC Single Once ant Number of antenna Specifies order of antenna operation with figure 1 4 max 9 characters Process time out msec 0 or from 100 to 5 000 in 10msec increments Additional information responded with data ANT antenna number CNT count of read tags EPC EPC code Additional tag information PEP PC bits and EPC code PER PC bits EPC code and CRC Refer to the Option Details in detail UA p 73 m O T Specifies password with 8 digit hex number 32 bit It is essential unless the 3 Access password value in the area of tag Access Password is zero It is active only when the area specified by tag is locked for read and write D Tag protocol 1 5 9 E Response Format 3 Response code SP Tag count SP TIF information SP SP TIF information Q 4 4 1 3 1 n 1 1 n Description 0000 Normal end For other Response codes refer to Response Code List 71 Response code Tag count Count of written tag s Tif information specified with command TIF information au Each optional value for tif information lines with comma separation UHF RFID System 78 User s Manual SECTION 5 Command Line Interface Command Response Example Write ID WTID WTID S WriteData S Options lt LF gt S Space cod
156. two or more tag exist in communication area e Is the antenna correctly connected with Reader Writer After connecting the antenna and the antena cable did you turn on power e Do not you write it in Lock Area e Is an enough electric power supplied to tag 5 it tag supported by Reader Writer e There is a possibility that Reader Writer is out of order when generated continuously e The mistake is found in the command code of the command UHF RFID System 152 User s Manual SECTION 8 Reference data Communications Time 154 Receiving Level Detection 157 m O UHF RFID System User s Manual 153 SECTION 8 Reference data Communications Time The following charts show communication time on each mode It is influenced on practical matters for example radio noise distance between tags materials tags are on and other environmental matters Communication time is measured in shielded room with one reader so that no reflection and no interference are considered You can refer these charts on determining time out value of the reader command But you must keep in mind actual communication time on your environment may not correspond to these charts because of the reasons already described Multi ID Read B Measurement condition at Communication Time environment Anechoic Chamber Distance 0 5 m fixation Distance between antenna and tag Condition Communication time required to
157. ty Interlock Switches Z235 E1 01 04 12 Note Specifications are subject to change 2014 Omron Electronics LLC Printed in U S A Printed on recycled paper
158. uide Example 1 Noise level check for the antenna port 1 Tx NOIS 0 1 LF Rx NOIS0000 0000032 00000345 000003B9 000003 0 00000339 lt gt UHF RFID System Users Manual 127 SECTION 5 Command Line Interface Undefined Command Illegal Command ICMD E Response Format Command code Response code 4 4 0000 Normal For other Response codes refer to Response Code List 71 Response code pueuiuo UHF RFID System 128 User s Manual SECTION 6 Browser Based Interface Using the Browser Based Interface Option Mode Safe Mode 130 131 145 UHF RFID System User s Manual 2 m O 129 SECTION 6 Browser Based Interface Using the Browser Based Interface You can display and operate the reader s Web interface by accessing the reader s IP address the default is 192 168 1 200 via Web browser enabled Java TM Runtime Only one user can access to this web interface at a time When a user A is operating via web interface and if another user B accesses to the same reader only the user B can operate it Composition of status screen and other menu buttons The menu buttons are located above on the opening status windows You can choose other operation menu by clicking this menu buttons The menu buttons are shown as below Reader Settings Comm Settings Operation Settings Utility http 192 168
159. unt is specified the command is executed and when the reader reads a single tag Tx seq ant 1234 tif PER ANT CNT lt LF gt Rx RDIDOO00 001 3000111111111111111111111111ABCD 2 8 lt LF gt The code is returned with comma separation EPC code including PC code 3000 and CRC ABCD antenna ID 2 and read count 3 are returned Example 4 When MultiRepeat Antenna 1 4 Antenna 1 is used as main antenna Timeout 1000ms is specified the command is executed and then the reader read 10 tags Tx RDID seq ant12131411 tmo 1000 lt LF gt Rx RDIDOOOO 010 111111111111111111111111 222222222222222222222222 7 Tag IDs AAAAAAAAAAAAAAAAAAAAAAAA lt LF gt Example 5 When MultiOnce Antenna 1 read items EPC LVL is specified the command is executed and when the reader reads two tags Tx seq MOC ant 1 tif EPC LVL lt LF gt Rx RDIDOOOO 002 111111111111111111111111 55 25 222222222222222222222222 48 125 LF Example 6 When an error occurred during communication process Tx RDID seq SOC ant 4 lt LF gt Rx RDID7011 lt LF gt The error code 7011 is returned UHF RFID System User s Manual 77 SECTION 5 Command Line Interface Write ID WTID E Command Format Written data Option 1 Option 12byte 24 characters Written data Specifies hexadecimal number in word 32 bits incremen
160. ut NEN Response NEN Response NEN Response Read Process Read Process Read Process U m O T Host Device Reader Writer RF Tag uoneoiunuiuio2 UHF RFID System User s Manual o m O T ewo esuodseg pueuiuio 66 SECTION 5 Command Line Interface Command Response Format Ethernet and RS 232C has almost the same command structure for command line I F Command frame has a Command Code area to control the R W and Command Data area that is used with Command Code Terminator that indicates the end of the frame is LF RS 232C requires a start code SOH check data and CR additionally The start code shall be at the beginning of the frame and the check data and the CR shall be just forward terminator LF Composition of command frame Command frame for RS 232C The shaded portion is only RS 232C FCS Calculation Range SOH Start Code Indicates the beginning of the frame with SOH For only RS 232C Command Code Specifies the command the reader executes Command Data Specifies the data for use with Command Code FCS etands for Frame Check Sequence hereinafter referred to as FCS The code is to detect an FCS error The result of the horizontal parity calculation from after SOH through just before the FCS is expressed by two characters of ASCII code For only RS 232C CR LF Terminator CR ODh LF OAh It is onl
161. xecution timing of the command is at in each execting timing It can be registered either from command I F or web brower I F The registered command is stored in the non volatile memory in the read and it enables at next boot up or reset The ON OFF status of IN1 to IN4 can be read from the host by issu Power On ing EXIO command Executing timing Power up or TCP IP connection The rising edge of input 1 signal The rising edge of input 2 signal The rising edge of input 3 signal Power On IN 1 IN2 IN3 IN4 The rising edge of input 4 signal Entered command Any given command Start Entered command End Start Entered command d process at Start Up process process at IN1 orodess process at IN2 process The reader executes the IN2 registered command during command execution It shows Error if you execute the command which is not permitted during execution If you registered the command which execute at boot timing it can be configure the simple self instruction system without host communication system or can be possible to self checking functionality for the system at the system boot Do not registered the Reset Command during powering up It causes failure of boot up of the reader CHECK UHF RFID System 42 User s Manual SECTION 3 Mode and Function Programmable output The programmmable output can output the reader operation status such as normal or er
162. y LF OAh when the command line is Ethernet The command frame length from the head to LF OAh is 512 bytes or less E Command frame for Ethernet Command Code Command Data 4 n 1 UHF RFID System User s Manual SECTION 5 Command Line Interface E Command Format perenne e m p Rm 4 1 n 1 n 1 n seem mm Digit Explanation number Consists of four characters in ACSII format Refer to Command Code List for information on command codes UA p 69 Between the elements Parameters and Options space has to be entered SP Space 20h for one or more character Even if a two or more characters of space are put in they work same way as one character space Command Code Mandatory for each command If there are multiple parameters in a single command they must be separated with some spaces and specified in the specified order Applicable parameter for each command is shown in the table in 3 1 5 1 Hyphen 2Dh The code in which the option is shown is set m O T Parameter Option item The option code is specified by three characters Optional for each command If there are multiple options in a single command they must be separated with some spaces If it is not specified default value will be employed If multiple option items are specified they shall be described continuously Any order is acceptable Optional value Commands are accept
163. y bank of a GEN tag for Read Data or Write Data shall be specified with the following number in decimal format 0 Reserved Area 1 EPC Area 2 TID Area 9 User Area o m O T Data Pointer Memory address in the memory bank of the GEN tag for Read Data or Write Data shall be specified with number s in the following range in decimal format Min 0 Max 255 Data Length Memory size to be accessed for Read Data shall be specified with the word number s in the following range in decimal format Min 1 Max 32 Note One word length is 16bits esuodseg pueuiuio Write Data To write data into a tag with Write ID or Write Data command the data shall be specified in 32 bit hexadecimal format as below 0x not required Format XXXXXXXX XXXXXXXX X 0to9 AtoF Ex 12345678 Lock Code When Lock command is executed this code shall be specified depending on the type of lock For GEN2 10 digit Lock value shall be specified with 0 1 or 0 and 1 mean Action and means MASK for following five areas Kill pwd Access pwd EPC memory TID memory and User memory Format X 0 10r 0 Off 1 Don t care chr Kill pwd Access pwd EPC memory TID memory User memory Action Fields UHF RFID System 72 User s Manual SECTION 5 Command Line Interface Option Details Option shall be specified with values following
164. ystem 104 User s Manual SECTION 5 Command Line Interface e Command Response Example Get Reader GETR GETR S Param1 Value1 S S ParamN ValueN lt LF gt S Space code param Setting item is specified by the sign GETRIRC S param1 value1 S lt LF gt RC Response Code S Space code param Setting item is set by the sign value Setting value is connected by equal sign and specified Note If the setting value includes any space the space shall be enclosed with double quotation Example 1 When Firmware version 100 100 100 0 is read Tx GETR fwv lt LF gt Rx GETROOOO fwv 100 100 100 0 lt LF gt Example 2 When Host name V750 BA50C04 IP 192 168 1 1 and Subnet mask 255 255 255 0 is read Tx Ihn lip Inm lt LF gt Rx GETROOOO Ihn V750 BA50C 04 lip 192 168 1 1 Inmz255 255 255 0 lt LF gt o m O Example When RS 232C Baud rate 19200bps Data length 7 bits Parity even and Stop 108 is read Tx GETR rbr rat rsb lt LF gt Rx GETROOO0 rbr 19200 rdt 7 rpb E rsb 1 lt LF gt Dunes UHF RFID System User s Manual 105 o m O T pueuiuio 106 SECTION 5 Command Line Interface Operation Setting Specifying following option in the operation setting command SETO or operation read command GETO enables to set or read the reader s operation settings Operation setting Command Entry Descripti

Download Pdf Manuals

image

Related Search

Related Contents

Samsung GT-I9305 Bruksanvisning  適合性検査申込書(様式第二)別紙 - JET 一般財団法人 電気安全環境  Application Note 4417 - Galil Motion Control  取扱説明書 - 863.63 KB  Canon iR Series User's Manual  Conditions, charges générales et indica  MT-091: Digital Potentiometers  Treiber und Software installieren    User`s manual (Canada version)  