Home

CF442 - 42" Bella

image

Contents

1. HANGER BALL SETSCREW DOWNROD Figure 6 MOTOR COUPLING SETSCREW CLEVIS PIN DOWNROD CLEVIS 0 CLEVI PIN R PIN UPPER HAIRPIN CLIP SETSCREW Figure 7 CEILING COVER DOWNROD COUPLING COVER Figure 8 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF442 3 Ceiling Fan Assembly continued 11 Reinstall the hanger ball Figure 9 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so A HANGER BALL the pin is captured in the groove in the top of the f CEILING hanger ball Pull the hanger ball up tight against the i pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble A WARNING SETSCREW It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling Figure 9 12 The fan comes with blue black and white leads that are 80 long Before installing fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 13 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan N EME
2. 2 Electrical Requirements Your new ceiling fan will require a grounded electrical The outlet box must be securely anchored and capable supply line of 120 volts AC 60 Hz 15 amp circuit of withstanding a load of at least 50 pounds If your fan is to replace an existing ceiling light fixture A WARNING turn electricity off at the main fuse box at this time and remove the existing light fixture To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 Ibs or less and use A WARNING screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not To avoid fire or shock follow all wiring instructions acceptable for fan support and may need to be carefully replaced Consult a qualified electrician if in doubt Any electrical work not described in these instructions should be done or approved by a licensed electrician A WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock EMERSON 4 U L Model No CF442 3 Ceiling Fan Assembly 1 Rotate the motor hub to align the hub motor area over each of the five shipping retainers One by on
3. 50 Ibs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING To avoid fire shock or injury do
4. and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for optional mounting accessories 13 Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF442 11 Repair Parts EMERSON 14 U L Model No CF442 11 Repair Parts Listing Model Numbers Description CF442AW00 CF4420RB00 CF
5. motor component or other accessory at no charge to you If repair of the motor component or accessory is not practical or possible within a reasonable time and no replacement Emerson Ceiling Fan can be provided Emerson will refund to you the actual purchase price of your Emerson Ceiling Fan We will ship the repaired or the replacement Emerson Ceiling Fan to you at no charge but you are responsible for all costs of removal and reinstallation of your Emerson Ceiling Fan How You Can Receive Warranty Service You must be the original retail purchaser and have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson Customer Service prior to your call please be prepared to provide all model numbers shown on your Emerson Ceiling Fan Once we have processed your return authorization request we will provide you with a postage paid return label which should be affixed to the Emerson Ceiling Fan package you ship to the address liste
6. the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 1 Read your owner s manual carefully and keep it for future reference 2 Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing 3 Do not put anything into the fan blades while they are turning 4 Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 2014 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7 kg
7. 4 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 14 EMERSON 10 lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 14 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod Your fan is now wired to be turned on and off from the fan switch A WARNING To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling 6 Cut the 3 speed switch pull chain to a desired length optional Connect the die cast pendant supplied to the 3 speed switch pull chain by sliding the die cast pendant small hole first onto the pull chain Attach the chain coupling to the end of the chain and allow the die cast pendant to fall down over the coupling U L Model No CF442 6 Using Your Ceiling Fan 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the pull chain switch 3 All fans are shipped from the factory with the reversing switch positioned down to circulate air downward If airflow is desired in opposite direction turn your fan OFF and wait for the blades to stop turning then slide the reversing
8. 442SW00 Hanger Ball Assembly 761655 21 761655 32 761655 92 Consisting of Hanger Bracket Hanger Ball Downrod 4 5 Parts Bag Containing Wire Connector 3 Pin Clevis 1 Clip Hairpin 1 Screw Flat Head M4 x 12mm 1 Screw Pan Head M6 x 14mm with Lockwasher 1 Screw Washer Head M5 x 6mm 16 Die Cast Pendant 1 Threaded Stud 2 Lockwasher 2 Knurled Knob 2 Coupler Pendant 1 Blade Balance Kit 1 Ceiling Cover 1 763785 AW 763785 ORB 763785 SW Wiring Harness 1 763981 4 763981 2 763981 4 Switch Housing 1 763795 AW 763795 ORB 763795 SW Coupling Cover 1 764053 AW 764053 ORB 764053 SW Fan Blade Flange set of 5 763908 AW 763908 ORB 763908 SW Fan Blade set of 5 763950 763950 2 763950 3 Owner s Manual BP7402 3 BP7402 3 BP7402 3 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 emersonfans com Please contact 1 800 654 3545 for further assistance 15 U L Model No CF442 EMERSON 16 U L Model No CF442 17 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF442 EMERSON 18 U L Model No CF442 Emerson
9. Air Comfort Ceiling Fan Limited Warranty What The Limited Warranty Covers This limited warranty is offered by Air Comfort Products division of Emerson Electric Co Emerson we or us located at the address stated below to the original retail purchaser you or your of an Emerson Air Comfort Ceiling Fan product Emerson Ceiling Fan and covers the motor and the other components and accessories of the Emerson Ceiling Fan against all defects in workmanship and materials What The Period Of Coverage Is This limited warranty will cover the Emerson Ceiling Fan motor for the expected lifetime of your Emerson Ceiling Fan when operated in accordance with your Owner s Manual or other instructions provided by Emerson to you with the Emerson Ceiling Fan All other components and accessories of the Emerson Ceiling Fan are covered by this limited warranty for a period of one 1 year from its date of original retail purchase ANY IMPLIED WARRANTY INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS AVAILABLE TO YOU UNDER THE LAWS OF YOUR STATE OR PROVINCE SHALL COVER THE MOTOR FOR THE EXPECTED LIFETIME OF THE MOTOR SUBJECT TO PROPER USE AND FOR ONE YEAR WITH RESPECT TO COMPONENTS AND ACCESSORIES No Other Express or Implied Warranty Applies THE LIMITED WARRANTIES PROVIDED ABOVE ARE THE SOLE AND EXCLUSIVE WARRANTIES PROVIDED BY EMERSON TO YOU FOR YOUR EMERSON CEILING FAN AND ARE IN LIEU
10. OF ALL OTHER WARRANTIES WRITTEN OR ORAL EXPRESS OR IMPLIED WHETHER ARISING BY OPERATION OF LAW OR OTHERWISE WHETHER OR NOT THE PURPOSE HAS BEEN DISCLOSED AND WHETHER OR NOT THE EMERSON CEILING FAN HAS BEEN SPECIFICALLY DESIGNED OR MANUFACTURED FOR YOUR USE OR PURPOSE EMERSON HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR COMPONENTS AND ACCESSORIES AS OF THE EXPIRATION OF THE ONE YEAR WARRANTY PERIOD FOR SUCH COMPONENTS AND ACCESSORIES IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR THE MOTOR PORTION OF THE EMERSON CEILING FAN ARE LIKEWISE DISCLAIMED BY EMERSON AT SUCH TIME THAT THE EXPECTED LIFETIME OF THE EMERSON CEILING FAN UNDER NORMAL USAGE HAS BEEN REACHED EXCLUSIONS OR LIMITATIONS OF IMPLIED WARRANTIES MAY VARY FROM STATE TO STATE AND PROVINCE TO PROVINCE SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU What We Will Do To Correct Problems If during the one 1 year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship or if during the expected lifetime of the Emerson Ceiling Fan when used in accordance with the User Manual or other instructions the motor is defective in materials or workmanship you must contact Emerson during the applicable warranty period If the defect is covered by warranty Emerson will repair or replace the defective
11. READ AND SAVE THESE INSTRUCTIONS EMERSON BELLA 42 Ceiling Fan Owner s Manual Model Numbers CF442AWOO Summer White CF4420RB00 Oil Rubbed Bronze CF442SW00 Satin White Net Weight 16 9 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 Part No F40BP74020003 Form No BP7402 3 Revision 131015 WWW emersonfans com U L Model No CF442 Table of Contents Section Page Safety Instructions 2 1 Unpacking Instructions 3 4 2 Electrical Requirements 4 3 Ceiling Fan Assembly 5 8 4 How to Hang Your Ceiling Fan 9 5 How to Wire Your Ceiling Fan 10 6 Using Your Ceiling Fan 11 Section Page 7 Maintenance 11 8 ACCESSONES leri nog ined tn ii a ety nae idea 11 9 Trouble Shooting 12 10 Energy Efficient Use of Ceiling Fans 13 11 Repair PariS li t oi ante a citat klan LAM 14 15 Ceiling Fan Limited Warranty 18 READ AND SAVE THESE INSTRUCTIONS Safety Instructions A WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in a manner intended by
12. RSON 8 U L Model No CF442 4 How to Hang Your Ceiling Fan A WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 10 A WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a U L outlet box listed as Acceptable for Fan Support of 22 7kg 50 Ibs ar SOO 1bs or less Figure 10 A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes N commonly used for support of light fixtures are not A OUTLET acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt TWO SCREWS SUPPLIED WITH OUTLET BOX 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box TAB BRACKET Figure 11 Figure 11 A WARNING Hanger bracket must seat firmly against outlet box If NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY the outlet box is recessed remove wall board until a bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall 2 Carefully lift the fan and seat the hanger ball gt HANGER downrod assembly on the hanger bracket that was N ai BRACKET just attached to the outlet box Figur
13. ake sure the screws which attach the fan flanges to the motor hub are tight A WARNING Make sure main power is turned off 4 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing Tighten screws securely 3 Fan wobbles excessively EMERSON Setscrew in motor coupler is loose Setscrew in the hanger ball downrod assembly is loose Screws securing fan blade flanges to motor are loose Fan blade flanges not seated properly Hanger bracket and or ceiling outlet box is not securely fastened Fan blades out of balance 12 Tighten both setscrews securely in the motor coupling Tighten the setscrew in the hanger ball downrod assembly Check to be sure screws which attach the fan blade flanges to the motor are tight Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on Ceiling Fan Assembly Tighten the hanger bracket screws to the outlet box and or secure outlet box Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation U L Model No CF442 10 Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation
14. contact 1 800 654 3545 for further assistance U L Model No CF442 3 Ceiling Fan Assembly continued 5 Remove and retain the three switch housing mounting screws Figure 4 from the switch housing plate Engage the connector of the switch housing assembly with the motor connector Figure 4 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 6 Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three M4 x 12mm flat head screws supplied Figure 5 A WARNING To avoid possible fire or shock do not pinch wires between the switch cup assembly and the switch cup plate EMERSON SWITCH HOUSING ASSEMBLY SWITCH HOUSING CONNECTOR SWITCH HOUSING MOUNTING SCREW 3 SWITCH HOUSING ASSEMBLY U L Model No CF442 3 Ceiling Fan Assembly continued 7 Carefully turn partially assembled fan upside down and place in styrofoam form carton in preparation for final installation 8 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 6 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 9 9 Separa
15. d at the end of this limited warranty The return label will be sent to the mailing address you provide to us by phone What Is Not Covered This limited warranty does not extend to and expressly excludes e The glass globes and light bulbs of your Emerson Ceiling Fan e Loss or damage to the motor or any component or accessory caused by normal wear and tear rather than due to defects in materials or workmanship e Loss or damage resulting from conditions beyond our reasonable control including without limitation repairs not made at our factory or authorized service center use of parts or accessories not provided to you as part of this warranty by our factory or authorized service center mishandling unreasonable use misuse abuse modifications or other damage caused by you or a third party to your Emerson Ceiling Fan while not in our possession e Loss or damage resulting from improper installation or other failure to comply with instructions in your Owner s Manual This limited warranty is deemed null and void upon the occurrence of either of the following events e You cease to own the Emerson Ceiling Fan product or e The Emerson Ceiling Fan is moved from its original point of installation This limited warranty is only valid within the 50 United States the District of Columbia and Canada No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on b
16. e unscrew each of the five screws and discard screws and shipping retainers Figure 1 2 Mount blade flanges to fan blades using three M5 x 6mm washer head blade screws Figure 2 NOTE Take care not to scratch fan housing when installing blades 3 Loosely attach one blade flange assembly to the motor hub by securing the two M6 x 14mm captive pan head screws Make sure the screws are NOT tightened Figure 3 Repeat this procedure for other four blade assemblies A WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades 4 The blade flanges have an interlocking feature that must be fully engaged before tightening the screw Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again SWITCH HOUSING ADAPTER REMOVE AND DISCARD THE FIVE SHIPPING SPACERS AND SCREWS FROM THE MOTOR HUB Figure 1 M5 x 6mm WASHER HEAD BLADE SCREW 3 per blade flange FAN BLADE FLANGE Figure 2 MOTOR HUB BLADE FLANGE ASSEMBLY MOTOR HUB NS MOTA uta m lt lt fe WS M6 x 14mm CAPTIVE PAN 5 HEAD SCREW 2 per blade flange assembly Figure 3 emersonfans com Please
17. e 12 Be sure the groove in the ball is lined up with tab on the HANGER BALL hanger bracket Figure 11 ki DOWNROD ASSEMBLY Figure 12 A WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard AA WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket emersonfans com Please contact 1 800 654 3545 for further assistance 9 U L Model No CF442 5 How to Wire Your Ceiling Fan If you feel that you do not have enough electrical NOTE CEILING COVER OMITTED FOR CLARITY wiring knowledge or experience have your fan BLACK AND BLUE installed by a licensed electrician GROUND FAN WIRES WIRE LISTED WIRE WHITE SUPPLY CONNECTOR 3 Z SS NEUTRAL A WARNING To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation GREEN WIRE 1 Connect the green grounding lead from the hanger MAN WHITE FAR ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this GREEN WIRE BLACK SUPPLY may be a bare wire or wire with green colored GROUND FROM HOT insulation Securely connect wires with wire HANGER BALL connectors supplied Figure 13 Figure 13 NOTE If you are usin
18. ed with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF442 9 Trouble Shooting A WARNING FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN TROUBLE 1 Fan will not start PROBABLE CAUSE Fuse or circuit breaker blown Loose power line connections to the fan or loose switch wire connections in the switch housing Reversing switch in neutral position SUGGESTED REMEDY 1 Check main and branch circuit fuses or circuit breakers 2 Checkline wire connections to fan and switch wire connections in the switch housing wire connections in the switch adapter A WARNING Make sure main power is turned off 3 Make sure reversing switch position is all the way to one side 2 Fan sounds noisy Blades not attached to fan Loose screws in motor housing Screws securing fan blade flanges to motor hub are loose Wire connectors inside switch housing rattling Screws holding blades to flanges are loose 1 Attach blades to fan before operating 2 Check to make sure the screws in motor housing are snug not over tight 3 Check to m
19. ehalf of Air Comfort Products or Emerson Electric Co Limitation of Liability REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE TO YOU UNDER THIS LIMITED WARRANTY TO THE EXTENT PERMITTED BY LAW IN NO EVENT SHALL EMERSON OR ANY EMERSON AUTHORIZED DEALER BE LIABLE FOR ANY INCIDENTAL SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING ANY ECONOMIC LOSS WHETHER RESULTING FROM NONPERFORMANCE USE MISUSE OR INABILITY TO USE THE EMERSON CEILING FAN OR FOR THE NEGLIGENCE OF EMERSON OR AN EMERSON AUTHORIZED DEALER EMERSON SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION WHETHER BASED IN CONTRACT INFRINGEMENT NEGLIGENCE STRICT LIABILITY OTHER TORT OR OTHERWISE SHALL EMERSON S OR ANY EMERSON AUTHORIZED AGENT S LIABILITY TO YOU OR ANY INDIVIDUAL USING THE EMERSON CEILING FAN EXCEED THE PRICE PAID BY THE ORIGINAL OWNER FOR THE EMERSON CEILING FAN The term consequential damages shall include but not be limited to loss of anticipated profits business interruption loss of use or revenue cost of capital or loss or damage to property or equipment How State and Provincial Law Relates To The Warranty Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This limited warranty gives you specific legal rights and you may also have other righ
20. g an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes ae commonly used for support of light fixtures are not acceptable for fan support and may need to be STUDS 2 replaced Consult a qualified electrician if in doubt LOCKWASHERS KNURLED 2 KNOBS 2 2 Securely connect the fan motor white wire to the Figure 14 supply white neutral wire using wire connector supplied Figure 13 Securely connect the fan motor 5 Secure the ceiling cover in place by sliding black wire and blue wire to the supply black hot wire using wire connector supplied Figure 13 After connections have been made turn leads upward and carefully push leads into the outlet box with the green equipment grounding conductor and white grounded neutral conductor on one side of the outlet box and the black and blue ungrounded conductors on the other side of the outlet box A WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result 3 Screw the two threaded studs supplied into the tapped holes in the hanger bracket
21. not use an Emerson or any other brand of control not specifically approved for this fan NOTE All setscrews must be checked and re tightened where necessary before installation DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use s EMERSON U L Model No CF442 1 Unpacking Instructions A WARNING Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 A WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration HARDWARE CONTENTS Description Threaded Studs 8 32 x 1 1 4 Knurled Knobs 8 32 Lockwashers 8 Wire Connectors Clevis Pin Hairpin Clip M5 x 6mm Washer Head Screws M4 x 12mm Flat Head Screw M6 x 14mm Pan Head Screw Lockwasher Die Cast Pendant Pendant Coupler Blade Balance Kit Ouantity PACKAGE CONTENTS Description Fan Motor Assembly Quantity Ceiling Cove
22. r Coupling Cover Fan Blades Blade Flanges Hanger Bracket Hanger Ball 4 5 Downrod Assembly Switch Housing Assembly NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF442 1 Unpacking Instructions continued This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly Installed Wire Length Wire Size A W G Up to 50 ft 14 One Phillips head screwariver Three wire 50 100 fi 12 One wire stripper connectors supplied One stepladder A WARNING Before assembly your ceiling fan refer to section on Materials proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or Wiring outlet box and box connectors must be of type experience have your fan installed by a licensed required by the local code The minimum wire would be electrician a 3 conductor 2 wire with ground of following size
23. switch to the up position and turn fan on again 4 The fan blades will turn in the opposite direction and reverse the airflow Your fan model is equipped with a 4 position 3 speed pull chain switch The operating sequence is as follows Three Speed 1st Pull HIGH 2nd Pul Medium 3rd Pul Low 4th Pul OFF 6s al ae SPEED REVERSIBLE SWITCH i SWITCH Reverse Switch Information Season Rotation Direction Switch Position Summer Counter Clockwise Down Winter Clockwise Up IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish A WARNING Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock 8 Accessories 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog 4 Ceiling Fan Blades see store or catalog A WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury 11 A WARNING This product is designed to use only those parts suppli
24. te untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Remove the upper setscrew from the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 7 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Reinstall the upper setscrew in the motor coupling Check that the lower setscrew is tightened securely Figure 7 NOTE The setscrews must be properly installed as described above or fan wobble could result A WARNING It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling 10 Make sure the grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure that the ceiling cover and the coupling cover are both oriented correctly Figure 8
25. ts which vary from state to state or province to province emersonfans com Please contact 1 800 654 3545 for further assistance 19 U L Model No CF442 NE w EMERSON Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Part No F40BP74020003 Printed in China Form No BP7402 3 Revision 131015 10 13 U L Model No CF442

Download Pdf Manuals

image

Related Search

Related Contents

MODULO IDRAULICO - Alpha  Dataflex CPU Protection Case 2 Fans 729  HPM10 - Power Management IC for Hearing Aids  The User Manual of    Mode d`emploi réductions AS ORTF 2012 - AS ORTF GOLF  ode56740a_2_felcom18  LFUE3 CN6204K/H003 1 2014年01月  TDSHーBA 東芝旧チャイムユニット取扱説明書・  

Copyright © All rights reserved.
Failed to retrieve file