Home

User Manual

image

Contents

1. 3P connector to RS232 Portof Building Distributor 3 Setthe dip switches of Building Distributor to match its assigned ID 4 Run NAME TOOL 200 exe file Rm Name 1 s 5 Select the Building ID in Select No on the menu 6 Select the port connecting with the computer in Select Port 7 Select Add to enter a resident number and name Name Management elect l EET lo E com z 8 Enter a resident number and name and then select OK to enter the next resident number and name can be entered up to 200 resident numbers and names Name Management 3 Cancel 9 Select Cancel to quit 10 In order to edit or delete selectthe resident number and name among the existing list of names as shown above and Then you can modify through the selection of Modify or Delete 11 Select Send to complete and save this information into the Building Distributor Management B E Read 1 z Modify Send Alete Exit Completed sending mur ouedo 12 Completed sending message is displayed as above select Y When LOBBY Not connected message is displayed please recheck the cable connection the Dip switches of the Building Distributor and Select No amp Select Port in the program menu while shutting off the Building Distributor Then select Send again while the Building Distributor is o
2. Type 5 cou MAX ANN 2 Part names and Functions 2 3 D 14 15 5 6 D 6 9 40 e 1 17 42 B No Contents No Contents 1 10 Power status and Light night lamp 2 Lamp for CCD Camera 11 Dial button 3 CDS Sensor 12 Key 4 CCD Camera 13 Cancel button 5 LCD Display 14 Camera angle control 6 Down button 15 Terminal for door release 7 Right and Left button 16 Volume control for receiving call 8 Call button 17 Connection terminal to CCU BS 9 Speaker This is the Entrance unitthatis connectable to up to 4 units with a Building Distributor C CU BS It can be connected with the Floor distributor unit C CU F S which connects 4 residence through the Building Distributor C CU BS 6 EM commax Calling In house unite by resident Number 1 Press the buttons according to the residence number and then Press A 2 After the residence answers you can talk with the in house unit 3 Beep will sound in the cause of a wrong number 4 Line Busy is indicated on the LCD of Multi Entry panel when already talking with others through the Panel R Calling In house unite by the listed resident names Register residents names into
3. normal operation 1 Setting Master 1 Setthe multi entry unit s ID number connected to channel 1 to 0 From the household number registration mode 2 While picking up the handset of an in house unit press the Extension call button and the door release button atthe same time 3 You can communicate with the Multi Entry Panel while the resident s number is displayed on it 4 When the x x M message is displayed on the Multi Entry Panel when you press the Door release button on an in house unit 5 Then register the ID of the shown residence and press button to hear a sound of completion 6 The registration is complete when you hang up the handset Repeat this process to register other room numbers 7 After completing registration of all household numbers be sure to set a multi entry units ID to 1 2 Setting the Sub Unit 1 Setthe multi entry unit s ID connected to channel 1 to 0 From the household number registration mode 2 While picking up the handset of an in house unit press the Extension call button and the door release button atthe same time 3 You can communicate with Multi Entry Panel while the resident s number displayed on it 4 In that status x S message is displayed on the Multi Entry Panel when you press the Extension call button on the in house unit 5 Then register the ID of the said residence and press V button to hear a sound of complet
4. B DRC MSC MSB CCU BS Wire 1 striped orange Wire 1 black Wire 2 orange Wire 2 navy dark blue Wire 3 striped green Wire 3 red Wire 4 green Wire 4 orange Wire 5 striped blue Wire 5 yellow Wire 6 blue Wire 6 green Wire 7 striped brown Wire 7 blue Wire 8 brown Wire 8 purple UTP CAT 5 TWIST PAIR 2 Wiring Please pay attention to the polarity ofthe wires Units will not work properly when mis wired When using a UTP CAT 5 cable be sure to check the connection ofthe color of the wires as shown in the picture above Within 20m between Build Distributor and Multi Entry Panel the power is supplied from the Building Distributor Greater than 20m to less than 100m between Build distributor and Multi entry panel the Multi Entry Panel requires separate power source In this case there is no power line connection between the Build Distributor and the Multi Entry Panel The allotted ID ofthe Multi Entry Unitshould match with the assigned number of the connection terminal of Building Distributor CCU BS Multi Entry Panel Build distributor ID 1 Terminal 1 ID 2 Terminal 2 ID 3 Terminal 3 ID 4 Terminal 4 When wiring please use a tool like a screwdriver LL pr E 16 EM commax 3 System diagram Household 8P Lobby 1 I
5. D 1 1 6 SLAVE2 Talk POWER GND DATA VIDEO 1 6 SLAVE 1 Talk GND DATA VIDEO Household Household 1 6 MASTER Talk POWER GND DATA VIDEO 6P 6P 1 6 Floor Distributor 1 8 CCU FS TALK DATA VIDEO POWER 1 8 Building Distributor CH2 CH3 CH4 CCU BS 1 8 TALK DATA VIDEO POWER 8P 8P 1 8 1 8 1 8 Lobby 2 ID 2 Lobby 3 ID 3 Lobby 4 ID 4 13 Specification Item Content DRC MS C MSB Wiring To Build Distributor 8 wire talk 2 Data 2 Video 2 Power 2 Power voltage DC24 DC28V 5A powered by building distributor Transmission Method Duplex System Screen dimension 128x64 GRAPHIC LCD Power requirement Standby 60mA Maximum operation 450mA Max Distance range to Build Distributor When power source is supplied from Building Distributor Less than 20m When power source is supplied separately 20 100m Distance range to Build Distributor 5Lux Lux 17 ARN
6. Home Network Since COMMAX Ce ee User Manual MULTI ENTRYUNIT DRC MSB MSC COMMAX Co Ltd WWW commax com COMMAX Co Ltd 513 11 Sangdaewon dong Jungwon gu Seongnam si Gyeonggi do Korea Int l Business Dept Tel 82 31 7393 540 550 Fax 82 31 745 2133 Thank you for purchasing COMMAX products Web site www commax com Please carefully read this User s Guide in particular precautions for safety before using a product and follow instructions to use a product exactly Printed In Korea 2010 03 101 The company is not responsible for any safety accidents caused by abnormal operation of the product Table of Contents Warnings and caution 2 Features 4 Part names and Functions 6 Calling In house unite by resident Number 7 Calling In house unite by the listed resident names 7 Calling talking duration 7 Open the entrance with PIN Number 8 Setting the ID for Multi Entry Panel 8 Setting In House unit aas master and Sub Units 9 Changing the password 10 Connectable Products 11 Resident registration program 11 Wiring and System Diagram 15 Specification 17 1 AEN Warnings and caution O Make sure to follow the instructions to prevent any danger or property losses Death or serious injury is expected A Warning Prohibition S It indicates prohibition G It indicates prohibition of d
7. c shock or an injury due to malfunction of the product Do notuse AC circuit breaker It may cause an electric shock varnings and caution N tion An injury or property losses are expected The socket holes are larger than usual Prohibition S It indicates prohibition G It indicates prohibition of disassembly It indicates prohibition of contact Q It indicates dos and don ts GC Itindicates that the plug should be pulled out from the socket Prohibition plug ora fire If the socket holes are larger Make sure that dust or foreign than normal do not put the substances are not gathered on the product It may cause an electric shock Prohibition Make sure to prevent foreign substances from entering the product It may cause a breakdown Do not put a heavy object on Do not disassemble or give an the product impactto the product It may cause a breakdown 2 Pulling the plug Avoid direct rays of the sun or heating devices ata time of installation Pulling the plug Oth
8. erwis properly Install the productin aflatand Pull the plug if the product is stable place not used for a long time e it may not function If the product generates strange sound make sure to pull the plug immediately and contact Commax service center 3 COMMAX Co Ltd EM 1 Features 1 Wiring 8 wires when including a power source Simple installation all wiring can be used with UTP cable CAT 5 2 Connect up to 4 Multi Entry Panels per building 3 Connect up to 4 residences per single Floor distributor CCU FS 4 Connect Multi Entry Panels with Building distributor CCU BS 5 The power source is required for each Multi Entry Panel DC24V or DC 28V according to the installation distance to Building Distributor 6 All the in house units Color Video P hone B W Video Phone or Audio Phone are DC source type products and only the Master Unitis supplied with a power source from the Floor Distributor C CU F S Additional in house units need a separate power source except for the Audio type in house unit AP 5HM 7 A door Camera unit does not serve as an individual door bell but a 2 wire door bell type is supported for an individual door e Multi Entry Units With its slim aluminum case and tempered glass camera lens the Multi Entry Panel is resistantto external impact It allows visitors to talk with residences list for names through the LCD display and easily register each residences name of each bu
9. ilding or assigned area into the Multi Entry Panel through the keypad or a personal computer Various selections are available among Video type with keypad DRC MSC MSB Video type by buttons DR C nS C nS B and Audio type DR nSB according to clients needs Using a DRC MSC color entry unit with a black amp white videophone unit as well as using a DRC MSB black amp white entry unit with a color videophone unit will cause blurred images 1 LCD size 128x 64 key pad type 2 Connecting Door Bell type for an individual door 3 Connectable to up to 4 units per building 4 Night automatic illumination white LED illumination built in Camera 5 Manual camera angle control 6 Full duplex 7 Power source DC 24V DC28V we a SS lt lt 4 EM commax 8 Screen display duration lasts for 30 seconds after receiving a call 9 Talking duration time last for 60 seconds 10 Temperature limit 10 440 C 11 Dimension mm 140 W x 341 H x44 D 12 Weight 1570g 140 44 341 0000 0000 0000 Installation om Flush Mount Type Surface Mount
10. ion 6 The registration is complete when you hang up the handset Repeat this process to register other room numbers 7 After completing registration of all household numbers be sure to seta multi entry unit s ID to 1 9 cou MAX 8 10 Changing the password 1 Changing Resident Password 1 Hold Residence Number and Key O button for 2 seconds and release when LCD stops blinking 2 Enter Current password 3 Hold Key z button for 2 seconds and release when LCD stops blinking 4 Enter New Password with 4 digits on Multi Entry Panel displaying NEW PW message 5 Hold Key button for 2 seconds and release when LCD stops blinking 6 Repeat New password to confirm it 7 Hold Key button for 2 seconds and release when LCD stops blinking 2 Changing Building Password default password 4321 1 Enter 9900 and then hold Key button for 2 seconds and release when LCD stops blinking 2 Enter current password and then hold Key lt button for 2 seconds and release when LCD stops blinking 3 Enter New Password with 4 digits on Muti Entry Panel displaying NEW PW message 4 Hold Key 9 button for 2 seconds and release when LCD stops blinking 5 Repeat New password to confirm it 6 Hold Key z button for 2 seconds and release when LCD stops blinking 3 Initialization of building password All the information of Building P asswords is stored in the Building D
11. isassembly It indicates prohibition of contact Q It indicates dos and don ts GC Itindicates that the plug should be pulled out from the socket Prohibition Prohibition Do not put the plug in the socket simultaneously Itmay generate abnormal heat or cause a fire D Prohibition Do not connect to other products while in use It may cause breakdown Do not forcibly bend the cord or put a heavy object on the product It may cause a fire Prohibition Prohibition Do not use water thinner ora detergent used to wash oil products when you wash the exterior Make sure to wash it by using a dry cloth to prevent any breakdown or electric shock Do not contact Do not install the productin a Do not forcibly pull out the humid place cord from the socket It may cause an electric shock or If the cord is damaged it may a fire cause a fire or an electric shock d Do not disassemble Do not put the plug in the socket with a wet hand It may cause an electric shock 2 commax Co Ltd Do not disassemble repair or modify the product It may cause a fire an electri
12. istributor C CU BS 1 Shut off the Building Distributor and open the unit s case 2 While pressing SW2 turn on the Building Distributor and the password will initialize to 4321 and the Lamp will blink for 3 seconds 10 EM commax 11 Connectable Products 1 Building Distributor C CU BS one Building Distributor is connected to up to 4 Multi Entry Panels Outside Distributor Floor distributor and Audio type guard station unit Building Serial Numbers are allocated to each Buildings Distributor by its Dip S witch 2 The Floor Distributor C CU F S one Floor Distributor can connect to up to 4 residences on each floor 3 In house unit master unit can connect to up to 2 Sub units per residence 4 Audio type unit this unit can be used for external unitto communicate to residences such as Guard station through one way communication 5 Program to register residences resident name is entered in the Building Distributor by a personal computer 17 Resident registration program TOOL 200 This program updates through the company web site WWW COMMAX COM 1 Download NAME TOOL 200 zip through COMMAX homepage and expand the zip files to a temporary folder ET n L Is MFC42D DLL is MFCN42D DLL NAME TOOL 200 is MFCO42D DLL MSVCRTD DLL TOOL_200 exe 2 Connect the side D sub connector of download cable to the serial port of the PC and Connect other side
13. mmon entrance will open 7 Setting the ID for Multi Entry Panel First setthe ID number sequence for the multi entry unit to 0 After each multi entry unit has been installed the user must program the building distributor s channels to correspond with each multi entry unit s ID number 1 to 4 1 10 1 CH2 10 2 CH3 10 3 10 1 If a multi entry units ID is setto 0 then itis in household registration mode If a multi entry units ID is setto 0 itis notin normal operation 1 Hold Key z button for 2 seconds and then release when the LCD stops blinking 2 When Password message appears on the LCD enterthe password setforthe Building and press the Key 9 button 3 When ID message appear on the LCD enter the number from 1 to 4 in order 4 Then press the Key button to complete ID setting 8 EE commax ws setting in house unit as Master and sub units Setup begins from the multi entry unit connected to channel 1 In one household there should only be one established MASTER multi entry unit The remaining units should be setas SLAVE units From the household number registration mode pressing the Door release button sets the unitas MASTER and pressing the Extension Call button sets the unit as SLAVE After completing registration of the household number set the multi entry unit s ID number to 1 If a multi entry unit s ID is set to 0 itis notin
14. n 13 The file ofthe resident numbers and names stored for Building No 1 is automatically saved in the format of AptNol e g Building No 2 gt AptNo 2 TXT in the same temporary folder 2 E AptNoa1 txt 1 n L is MFC420 DLL MFCN42D DLL NAME TOOL 200 MFCO42D DLL MSVCRTD DLL BA NAME TOOL 200 exe 14 Select E xit to quit this program Select READ brings the data from existing information of resident numbers and names in the Building Distributor as shown in the image below 16 List appears when selecting READ which is then saved into Name Management by selecting OK But for example in case there is existing data stored in the temporary folder in the format such as AptNo1 txt shown above Name list shown below will not take priority to be saved over the existing data AptNo1 txt 14 EM commax Management LI x Select Port 17 With this data you can make use ofthe modify Add functions in this program and select SEND to complete 13 Wiring and System Diagram 1 Wiring Diagram When powered from B D When supplied from a separate power source OOO OO Oyo TALK DATA VIDEO POWER TALK DATA VIDEO POWER aAO00O0DO00 00 DRC MSC MSB DRC MSC MS
15. the CCU BS through Programming for register residence list A maximum of 200 names can be registered with up to 18 digits each The name can be strolled through alphabetical order 1 Press one of W 4 gt A buttons to display A Z on LCD to select resident name that you are looking for 2 Press V to select one of them from A to Z which includes the resident name that you are looking for 3 Press 4 0 scroll to resident name section and Press W to select the resident name that you are looking for 4 Press A to call the residence Line Busy is indicated on the LCD of the entry panel when itis connecting with the same residence a 5 Calling talking duration 1 Calling duration lasts for 30 seconds 2 Talking duration lasts for 60 seconds 3 Press X button to end WE Open the entrance with PIN Number 1 Opening the common entrance with Household Number Note The doors do notopen by default password 1234 Only after changing default Password to new one can you use this function 1 Press resident number and KEY 9 button 2 Press PIN number and the KEY 9 button The door opens with the OPEN message display on the LCD screen N Opening the common entrance with PIN Number 1 Enter the number sequence 9900 2 Press the KEY button 3 Enter the PIN number of a building 4 Press the KEY button 5 If the OPEN message appears the co

Download Pdf Manuals

image

Related Search

Related Contents

  escáner de imágenes m3096ex y m3096gx guía del usuario  MP-25 RED DE MONITOREO CLIMÁTICO PARA DAR APOYO A LA  広報 - 嘉手納町  SYSMAC CS/CJ-series CS1W-PRM21/CJ1W-PRM21  ArmorStart Distributed Motor Controller User Manual  latur - Maharashtra Animal & Fishery Sciences University  ƒXƒJƒCƒuƒŒƒ“ƒ_ [ ³”F..    «L`innovation, c`est pour tous!»  