Home

Owner`s Manual with RS-232

image

Contents

1. Pallet Scale 8 HOW TO CHARGE 1 Plug the charger into a AC socket and make sure that the socket s power is within the charger s operating range Open the socket s cover located on the right side of indicator and then connect to the connector See Fig 1 2 Depending on the charging state the lamp located on the charger will be ON 3 When the battery is fully charged the charger lamp will be ON 4 It takes about 8 hours to fully charge the battery CONNECTOR WIRE gt Fig 1 9 TEST MODE 1 HOW TO ENTER Turn on the power while pressing the ZERO key and TEST menu starts 2 AVAILABLE KEYS amp CONVERTING METHOD A KEY Increase the first place set value to 1 KEY Move to the left by 1 place of the set value PRINT kg lb version or kg version KEY Move to a weight measure mode ON OFF KEY Move into next menu Pallet Scale 3 TEST MENU TEST1 TEST 5 TEST 1 Key test TEST 2 LCD display test TEST 3 Load cell test and A D conversion test TEST 5 Print test TEST 1 FUNCTION Key test KEY LGD DISPLAY DESCRIPTION Test 1 condition tESt 1 OMIDFF key Next menu 1 Press the key to be lest and Other key Perform test the and code of the key is 1 displayed lt Key code gt KEY GODE KEY CODE KEY GODE ZERO TARE GROSS NET 3 PRINT kg versioni 4 amp g version 3 ONOFF 6 kgb Ikplb versioni 4 PRINT kg varsion
2. 1 8 0 Always display weight in Normal 1 When stable display weight in Normal Pallet Scale 11 Error message amp Troubleshooting Err 01 Reason The weight is too unstable to initialize the scale Troubleshooting Lay the scale on a plat place and turn on the power Err 02 Reason Load cell connection failure or error in A D conversion part Troubleshooting Check the load cell connector to see if the polarity of signal is reversed Err 06 Reason Error in printer connection t Troubleshooting Check with printer connector If there is no problem with printer and printer connector please request A S to head office Err 08 Reason The ZERO key or TARE key is adjusted not to be operated under the unstable condition Troubleshooting Press Zero or Tare key in stable condition Err 09 Reason Current weight deviates from zero range Troubleshooting Press the ZERO key within 1096 of the maximum capacity Pallet Scale Err 10 Reason Tare weight exceeds the maximum capacity of the scale t Troubleshooting Set the tare to be smaller than the maximum capacity Otherwise the maximum capacity is reset to be larger than the tare to be set in the calibration menu and reset the calibration using weight Err 13 Reason The zero range deviates from the set range Troubleshooting Confirm that there is nothing on the weighing platfo
3. the weight is stable O ZERO lamp ON when the current weight is 0 kg 0 Ib O NET lamp ON when the current weight is NET weight O BAT lamp In case of rechargeable battery display the battery recharging time Battery warning lamp If Battery warning lamp turn on CPS will power off after about 30 seconds Pallet Scale 2 Keyboard 4 Key Available keys instead of numeric keys A Change the set value Increase the first place value to 1 4 Change the digit of the set value Move to the left by 1 place USAGE Input the numeral value in TEST SET mode O ZERO Key Return the display to 0 L TARE Key Use container in weighing Current weight is memorized as tare weight If you press TARE key in unload condition Tare setting is released O GROSS NET Key Display gross and net weight by turn GROSS lamp on gross weight NET lamp on net weight In case tare weight is REGISTERED tare and item s total weight is G weight and only item s weight is N weight O kg lb Key Only kg lb version Toggles between and kg units C1 PRINT Key 1 PRINT Key Total Print key by pressing PRINT key more than 3 second 2 HOLD Key O key Only kg version 1 Total print key FO9 1 2 Hold key F09 2 O ON OFF Key 1 Back light ON OFF key 2 ON OFF key by pressing key more than 3 second 3 Store current condition and exit in TEST SET mode Pallet Scale 6 RS 232C OPTION 1 How to RS 2
4. 32C Select switch SIDE PART OF CPS 2 How to connect PC Connect the serial port on the rear panel of the indicator to serial port of PC as follows 3 2 Transmit Data TXD 2 3 Receive Data GND 70 7 Signal Ground r O 8 Carrier Detect 1 20 Data Terminal Ready 6 Data Set Ready 4 Request to Send L 0 5 Clear to Send 9 pin port Male 25 pin port Female RS 232C port of CPS Series Serial port of computer Pallet Scale 3 3 Transmit Data TXD 2 2 Receive Data GND 5 Signal Ground r 1 Carrier Detect 4 Data Terminal Ready 6 Data Set Ready 7 Request to Send L 0 8 Clear to Send 9 pin port Male 9 pin port Female RS 232C port of CPS Series Serial port of computer 3 How to connect Sub display RXD 2 Transmit Data TXD 2 3 Receive Data GND 7 7 Signal Ground 9 pin port Male 9 pin port Female RS 232C port of CPS Series Serial port of computer 4 Data format 0 Baud rate 1200 bps 19200 bps Set Baud rate in SET mode See F20 at page 30 2 D
5. KEY version KEY Move to a weight measure mode ON OFF KEY Move into next menu 3 SET VALUE CONVERSION MENU F01 F18 F01 Select the primary base unit kg lb F02 Designation of serial port usage Automatic zero condition set F04 Digital Filter FO7 Weight Back up Power on Actual Weight F08 PRINT Key Usage F10 Device ID F11 Designation of Serial Interface Baud rate F12 Designation of Serial Interface output mode F13 Set HOLD type F14 Select of clock option F17 Print line feed F18 Display mode Pallet Scale Select the primary base unit Only kg lb version O primary unit is kg FO1 1 primary unit is Ib Serial port usage Connection to serial Printer Fo2 gt Not Usage Automatic Zero tracking O None Automatic zero F03 1 0 5 digit Auto zero tracking will automatically bring the display back to 0 when there are 9 4 5 digit small deviations Digital Filter 0 None Digital filter F04 1 1 Less Vibration Adjust the set value according to the condition 9 9 Much Vibration Select the weight back up mode 7 Weight back up is off Power on Zero 1 Weight back up is on PRINT Key Usage Only kg lb version O Not used F 0 8 41r Print key Total Print key by pressing PRINT key more than 3 second 2 HOLD Ke
6. PALLET SCALE CPS SERIES OWNER S MANUAL CAS Pallet Scale Table of Contents 1 PREFACE 3 2 OVERALL VIEW 4 3 SPECIFICATIONS 5 i ETEN l eec 6 RS 232C OPTION 8 7 OPERATIONS 10 23 ES 11 ERROR MESSAGE AND TROUBLE SHOOTING 19 Pallet Scale 1 PREFACE Thank you for the purchasing of our CAS CPS Series These series have been designed with CAS reliability under rigid quality control and with outstanding performances Your speciality departments can enjoy with these high quality reliable CAS products These electronic load cell scales eliminate the all the moving parts and furnish an accurate digital display of all information We believe that your needs will be satisfied and you will have proper reliability in variable weight This manual will help you with proper operations and care of the CPS scales Please keep it handy for the future references CAUTIONS Do not press the keys hardly for the keys are in operation with soft touch Do not use ignitable material for cleaning Keep away 2001 from the rain Avoid sudden temperature change Do not install CI 2001B in a place with high voltage and excessive electrical noises Keep it in dry place Do not use under direct rays and dusty place Do not use at the place with excessive electrical noises and vibration FEATURES CAS PALLET SCALE CPS weigh the pallet loads
7. ata bit 8 Stop bit 1 Parity bit None 3 Code ASCII When data is sent to computer Set in SET mode See F12 at page 31 Format DATA 8 byte CR LF US Unstable GS GROSS weight Device ID Lamp condition byte Empty Unit kg t ST Stable NT NET weight OL Overload Pallet Scale Device ID Transmit 1 byte so that the receiver can receive data selectively which indicator sent Device ID is selected in F10 Weight Data 8 byte 13 50 8 s b 135 SY 10 4 35 5t Gcedab 179525 6 OPERATIONS 1 How to assembly 10 Pallet Scale 2 Operations 1 Turn the power switch ON The power switch is located on the right side of the indicator WARNING Avoid leaving ANY load before turn the power switch ON 2 Pressing ON key of front panel 3 Display will show 0 make sure that ZERO lamp is ON 4 When the FORK lift the load weighing is performed WARNING Fork have to properly level so as to center bubble of the leveling gauge inside the indicated circle and fork truck should not move 5 If you want to adjust zero range press the ZERO key 6 If you want to use tare function press the TARE key If you don t want to use tare function any more remove the container pallet and press the TARE key 7 If you want to down the fork pull the DOWN LEVER If you want to lift the fork press the STOPPER and operate the LIFT HANDLE
8. i Pallet Scale TEST 2 FUNCTION LOD display test LOO DISPLAY DESCRIPTION tESt 2 Test 2 condition 88888 TEST 2 is performed automatically Ref 1 Program is automatically shifted to menu selection mode after completing TEST 3 FUNCTION AD conversion test LC testi KEY LCD DISPLAY DESCRIPTION tESt 3 Test 3 condition key Next menu Other key Perform test Display digital value of current 5500 weight This value means converted digital value Ref 1 Check whether digital value is changing If the digital value is fixed or zero is displayed Please check the connection of the load cell TEST 5 FUNCTION Printer test KEY LOO DISPLAY DESCRIPTION Test 5 condition tESt 5 QRAOFF key Exit test mode 1 error in printer Other keys Perform test G00d a 06 Check printer connector Ref 1 Good message is displayed if the printer connection and specification is done correctly if not Err 06 message is displayed Ref 2 The test output format of printer is like follows TEST OK Pallet Scale 10 SET MODE 1 HOW TO ENTER Turn on the power while pressing the TARE key and SET menu starts 2 AVAILABLE KEYS amp CONVERTING METHOD A KEY Increase the first place set value to 1 4 KEY Move to the left by 1 place of the set value PRINT kg lb version
9. rm If nothing exist do calibration in CAL mode Over Reason The weight on platform is too heavy to be measured t Troubleshooting Do not load the item exceeds the maximum tolerance If the load cell is damaged the load cell should be replace
10. with accuracy CPS s lift and read technology speed the loading and weighing process We have 1000kg and 2000kg capacity models Digital indicator displays the weight Built in printer optional You can record the weight of loads with printer Built in battery You can use this scale without power outlet NOTICE Specifications are subject to change for improvement without notice Pallet Scale 2 OVERALL VIEW POWER ON OFF SWITCH DOWN LEVER _ NDICATOR CHARGER CONNECTOR x i R5 232C PORT RS 232C SELECT S W STOPPER LIFT HANDLE PRINTER OPTION A LOADING PLATE LEVELING GAUGE FORK Pallet Scale 3 SPECIFICATIONS MODEL NAME CPS 1 CPS 2 TYPE A B B A B G SIZE 17 540 620 705 540 620 705 L 1080 1080 1200 1080 1080 1200 CAPACITY 10000 0 50 2000lbx1lb 20000 x10 5000lbx2lb OVERLOAD PROTECTION 15000 300015 25000 55001 WEIGHT DISPLAY 5digit LCD HEIGHT 25mm POWER SUPPLY DC6V 10AH BATTERY AC 110V 220V CHARGER ACCURACY 0 1 OPTION PRINTER PC Connection TEMPERATURE RANGE 10 C 40 C 4 DIMENSIONS Pallet Scale 5 FRONT PANEL kg version llo CAPACITY LIGHT zo lane E omme 4 4 1 1 Display lamp O lb lamp ON when the weight unit is pound lb O kg lamp ON when the weight unit is kilogram kg O lamp ON when
11. y Pallet Scale Key Usage Only kg version Not used F09 1 Total Print key 2 HOLD Key Device ID 00 Device ID 00 F 1 0 It is used the no of indicator when system is connected 99 Device ID 99 Baud Rate 600 bps 1200 bps 2400 bps 4800 bps 9600 bps 19200 bps F11 D Output Mode No data output Stream Mode F12 Transmit only in stable condition Transmit when data is required Request signal device ID F10 Device ID In case F10 1 Send Hex Value 01h in Computer N O Set HOLD type 0 Average hold Compute the average weight of oscillating weights F1 3 1 Peak hold Compute the maximum weight among oscillating weights 2 Sampling hold Compute the current weight Pallet Scale Select Option Clock F1 4 Not use Clock 1 Use Clock Change Date Time Ex 1998 12 11 13 10 01 LCDisplay Meaning C1 98 Year 98 Increase of no Month 12 4 Shift of digit C2 12 LIGHT Store and C3 11 Day 11 move into next menu C4 13 Hour 13 C5 10 Minute 10 C6 01 Second 01 Print line feed 1 1 Line feed 2 2 Line feed F 1 7 3 3 Line feed 4 4 Line feed 5 5 Line feed Display mode

Download Pdf Manuals

image

Related Search

Related Contents

  PROCESO DE TRAMITACIÓN DE LA SOLICITUD ÚNICA EN  Componentes varios del sistema de bebederos de boquilla  E8a Emulator Additional Document for User`s Manual  STEBA SV 2  Manuale d`uso User manual  Toshiba NB305-N600  Manual del usuario GUIDA Contabilidad Grabación de  ICE50 User Guide  User manual Profibus  