Home

DVI-SDI-2-SFP User manual

image

Contents

1. ssssseseesesssesrrrreeen 12 Product Warranty asar ina tere Taa aaaea e 13 Appendix A Materials declaration and recycling information nnnnnnnnnnnnnnnneenne 14 A 1 Materials declarant a A A petite ae id 14 AZ R cycling MO Mal tordo EA 14 nevion com 3 DVI SDI 2 SFP Rev C 1 Product overview DVI SDI 2 SFP will convert DVI R or HDMI signal into an optical SDI Used together with DVI SDI 2 SFP this card can be used as an optical extender for transporting DVI signal The dual optical transmitter is SFP based and can be 1310nm for short haul application or 18 channel CWDM transmitter The CWDM option can be combined with Flashlink CWDM 18 filter making it possible to transport 18 DVI signals over one fiber HDMI DVI input 1 Optical output 1 HDMI DVI input 2 Optical output 2 Microcontroller Remote control Figure 1 Block diagram of the DVI SDI 2 converter nevion com 4 DVI SDI 2 SFP 2 Specifications 2 1 General Power Control Temperature range 2 1 Electrical Inputs Number of inputs Connector Supported format Number of bits Bandwidth Format RGB Range Audio embedding 2 2 Optical output Number of outputs Connector SFP type Rev C 5V DC 5W max Control system for access to setup and module status with BITE Built In Test Equipment 0 to 40 C 2 HDMI type D HDMI type A with use of adapter cable DVI D with use of adapter cable 525i 625i 720p 1080i 50
2. Figure 3 DVI SDI 2 board layout AA Tee pe REES E Ea rs EES rs EELER SIT LE ET LE OVR Override GYDA GYDA control Select configuration control Configuration with from GYDA Configuration with GYDA DIP switch All DIP switches are off when pointing towards the release handle nevion com 7 DVI SDI 2 SFP Rev C 5 Connections SFP1 SFP2 SFP3 Ce nevion Figure 4 Connector module for DVI SDI 2 5 1 Mounting the connector module The details of how the connector module is mounted is found in the user manual for the sub rack frame FR 2RU 10 2 This manual is also available from our web site http www nevion com 5 2 Terminal ports The connector module must be fitted with three SFP s SFP3 is for the dual optical receiver module While the SFP1 and SFP2 are for the HDMI DVI SFP The HDMI DVI SFP are fitted with an HDMI type D connector if other connect are preferred see chapter Error Reference ource not found for alternatives Terminal Function Supported Format Format Mode a a output a IO SD HD 3G SDI SFP Electrical Electrical input HDMI or DVI or DVI a io input E or DVI GPI ALARM Open Collector Alarms OC Output Unused inputs should be terminated to avoid alarms triggered by noise nevion com 8 DVI SDI 2 SFP Rev C 5 3 Cable adapter 5 3 1 HDMI type A An HDMI type D to HDMI type A can be delivered with the module for interfacing for interfa
3. s Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the product to Nevion or its agents for recycling the following general information may be of assistance Before attempting disassembly ensure the product is completely disconnected from power and signal connections All major parts are marked or labeled to show their material content Depending on the date of manufacture this product may contain lead in solder Some circuit boards may contain battery backed memory devices nevion com 14
4. 59 94 60Hz 1080p 50 59 94 60Hz 640x480 converted to 720p by adding black lines 800x600 converted to 720p by adding black lines 1024x768 converted to 1080p by adding black lines 1280x1024 converted to 1080p by adding black lines Other graphical format may work 24bit 3x8bit 165MHz RGB 4 4 4 YCbCr 4 2 2 YCbCr 4 4 4 Only non HDCP protected signal Full or SMPTE 2 channels AES 1 group L PCM 48kHz 2 LC UPC Nevion Video SFP range Dual transmitter See SFP datasheet for additional specifications 2 3 Standards SMPTE292M SMPTE259M SMPTE297M SMPTE425A SMPTE425B SMPTE424M nevion com 5 DVI SDI 2 SFP Rev C 3 Operation E BEE E Si e Electrical to m j converter Re clocker Audio embedden optical converter Optical output 1 HDMI DVI input 1 m w pe E Re clocker Audio embedder e GE Optical output 2 HDMI DVI input 2 L LS W Figure 2 Signal flow The electrical DVI HDMI signal is converted into an electrical SDI signal The audio is embedded into the SDI signal before the SDI is converted to optical by the optical SFP In DVI mode no audio is embedded into the SDI signal nevion com 6 DVI SDI 2 SFP Rev C 4 Configuration The correct configuration can either be set with a DIP switch or with the GYDA Control System The layout of DVI SDI 2 is shown in the drawing below with the DIP switch to the upper left position ey mevion STATUS Halt To IT Chet
5. at the front of the module The LEDs are visible through the front panel as shown in the figure below STATUS O LOS LOCK1 LOS LOCK2 The DVI SDI 2 has 4 LED s each showing a status corresponding to the GPI pinning SFP Diode State Red LED Yellow LED Green LED No light Status Module is faulty or N A Module is OK Module module is initializing Module power has no is OK power LOS LOCK1 No input signal on Channel 1 is not Channel 1 is in Missing input 1 in lock or lock and SFP on unsupported supported signal 1 format format LOS LOCK2 No input signal on Channel 2 is not Channel 1 is in Missing input 2 in lock or lock and SFP on unsupported supported signal 1 format format Transmitter Missing SFP NA Present GER NA Table 1 LED states and what they mean nevion com 11 DVI SDI 2 SFP Rev C General environmental requirements for Nevion equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operating room temperature 0 C to 45 C range Operating relative humidity range lt 90 non condensing 2 The equipment will operate without damage under the following environmental conditions Temperature range 10 C to 55 C Relative humidity range lt 95 non condensing nevion com 12 DVI SDI 2 SFP Rev C Product Warranty The warranty terms and conditio
6. cing to HDMI type A equipment 5 3 2 DVI D An HDMI type D to DVI D can be delivered with the module for interfacing to DVI D equipment nevion com 9 DVI SDI 2 SFP Rev C 6 Module status The status of the module can be monitored in three ways 1 Multicon Gyda System Controller optional 2 GPI at the rear of the sub rack 3 LED s at the front of the sub rack Of these three the GPI and the LED s are mounted on the module itself whereas the GYDA System Controller is a separate module giving detailed information on the card status 6 1 Multicon Gyda 6 2 GPI ALARM Module Status Outputs These outputs can be used for wiring up alarms for third party control systems The GPI outputs are open collector outputs sinking to ground when an alarm is triggered The GPI connector is shown in figures below Electrical Maximums for GPI outputs Max current 100mA Max voltage 30V 6 2 1 GPI connections DVI SDI 2 module GPI pinning Signal Name Pin Mode Status General error status for the module Pin 1 Open Collector LOS1 Loss of signal or missing SFP on Pin 2 Open Collector channel 1 LOS2 Loss of signal or missing SFP on Pin 3 Open Collector channel 2 Ground OV gnd pin Pin8 ON 8 wire RJ45 Figure 1GPI connector nevion com 10 DVI SDI 2 SFP 6 3 Front panel Status monitoring The status of the module can be easily monitored visually by the LED s
7. nevien DVI SDI 2 SFP Dual DVI to optical SDI converter User manual Rev C DVI SDI 2 SFP Rev C Nevion Support Nevion Europe Nevion USA P O Box 1020 1600 Emerson Avenue 3204 Sandefjord Norway Oxnard CA 93033 USA Support phone 1 47 33 48 99 97 Toll free North America 866 515 0811 Support phone 2 47 90 60 99 99 Outside North America 1 805 247 8560 E mail support nevion com See http www nevion com support for service hours for customer support globally Revision history Current revision of this document is the uppermost in the table below Rev Repl Date Sign Change description B 2014 05 22 AJM Minor updates before release C B A 2014 02 24 SHH Updated manual A 2012 02 28 AJM First version nevion com 2 DVI SDI 2 SFP Rev C Contents REVISIONS EON fete eee ha the A A See et ee e tee teeta 2 1 Product overview EE 4 2 SSC A Le EE 5 VA RE 5 A EE E E AEE 5 ET e 5 23 e E EE 5 Opera lletra consista loca sia ell lao eto todita 6 AUN LI le EE 7 5 CGONNECHOMS eege 8 5 1 Mounting the connector module ebe ee ee dE 8 5 2 Terminal ponsi e e 8 5 3 Cable Adapter eee dr 9 EI DEE ee 9 E AER EE 9 Mod le AUS ION 10 6 1 Multicon Gyda sii ds 10 6 2 GPI ALARM Module Status Outmmuts 10 6 21 PL COINS ele CR 10 6 3 Front panel Status monitoring eege Ee EE ae ci 11 General environmental requirements for Nevion equipment
8. ns for the product s covered by this manual follow the General Sales Conditions by Nevion which are available on the company web site www nevion com nevion com 13 DVI SDI 2 SFP Rev C Appendix A Materials declaration and recycling information A 1 Materials declaration For product sold into China after 1st March 2007 we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products In the first stage of this legislation content of six hazardous materials has to be declared The table below shows the required information Toxic or hazardous substances and elements ERER Si R i ACHR SSES SS ZS Part Name Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated Pb Hg Cd Chromium biphenyls diphenyl ethers Cr VI PBB PBDE lt Product gt O O O O O O lt Power supply if delivered with unit gt O O O S a S O Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ T11363 2006 X Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ T11363 2006 This is indicated by the product marking A 2 Recycling information Nevion provides assistance to customers and recyclers through our web site http www nevion com Please contact Nevion

Download Pdf Manuals

image

Related Search

Related Contents

    Genesis Advanced Technologies Saw GTS10S User's Manual  Brokerage User Manual - Oracle Documentation  Image IMTL39606.2 User's Manual  MANUAL DO USUÁRIO  FIJI SPAS - Sunrise Tradex  

Copyright © All rights reserved.
Failed to retrieve file