Home

Manual - MyFlukeStore.ca

image

Contents

1. use if damaged The Recorder is for indoor use only The Recorder is a direct plug in unit and must be plugged only in applicable and standard sockets Distribution circuits must be fused If there is reason to believe that safe operation is no longer possible the Recorder should be disconnected and secured from unintentional reconnection The Recorder must be opened only by qualified personnel Always unplug the Recorder before cleaning Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 A Caution Voltage Quality Recorder Standard Equipment To avoid damaging the Recorder follow these guidelines Do not use aromatic hydrocarbons or chlorinated solvents for cleaning These solutions will react with the plastics used in the Recorder Safety and electrical symbols used in this manual and on the Recorder are displayed in Table 1 Table 1 Symbols Hazardous voltage Risk of electrical shock Conforms to relevant European Union directives Do not dispose of this product as unsorted waste Go to Fluke s web site for recycling information Double insulated Conforms to relevant Australian standards This equipment is designed to protect against transients from energy consuming equipment supplied from the fixed installation such as televisions personal computers portable tools and other household appliances Conforms to relevant Canadian and US Standards Lithium Batter
2. FLUKE VR1710 Voltage Quality Recorder Users Manual October 2007 2007 Fluke Corporation All rights reserved All product names are trademarks of their respective companies Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service The warranty period is one year and begins on the date of shipment Parts product repairs and services are warranted for 90 days This warranty extends only to the original buyer or end user customer of a Fluke authorized reseller and does not apply to fuses disposable batteries or to any product which in Fluke s opinion has been misused altered neglected contaminated or damaged by accident or abnormal conditions of operation or handling Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non defective media Fluke does not warrant that software will be error free or operate without interruption Fluke authorized resellers shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of Fluke Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable interna
3. HER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE OR THEORY Since some countries or states do not allow limitation of the term of an implied warranty or exclusion or limitation of incidental or consequential damages the limitations and exclusions of this warranty may not apply to every buyer If any provision of this Warranty is held invalid or unenforceable by a court or other decision maker of competent jurisdiction such holding will not affect the validity or enforceability of any other provision Fluke Corporation Fluke Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands 11 99 To register your product online visit register fluke com Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 Table of Contents Title Page Mint O DUG ONs sccseiasdeshens sede Peadlastacsdexasta ea A E a AS Contacting Fluke snene oenn oE E E E ETT E Safety Information cccccceccceeseesceescecscecseecesecesecesessseseeeeseeeseeeseseeeseeeeeenseentees Standard Equipment sinss ioir a e E E R E R E The Recorder at a Glance seseseesseseseeeseseesessesessessststtsssssesresssseststesssseseeens Using the Recorder sicciss ctecssnstovasunivora
4. cialists can also send the Recorder to a utility consumer who can connect it to their own electric outlet for a specified period When finished taking data the consumer can then send the Recorder back to the electric utility specialist The specialist can analyze the collected data with Power Log software Settings collected data and real time clock data stay intact in transit via the Recorder s non volatile memory Downloading and Analyzing the Data with Power Log m To download the data from the Recorder open Power Log and click _ _ Data Download Recorder data is downloaded to the PC Power Log asks if you wish to keep measuring data and presents three options e Keep measuring Yes e Stop measuring No e Keep measuring but erase the Recorder memory up to the point of data download Yes and Erase memory Note that all prior measurement data will be lost so make sure to save the data in Power Log before exiting For in depth information on data analysis see Analyzing Data in the Power Log Users Manual on the Product CD Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 Voltage Quality Recorder Maintenance Maintenance The Recorder is maintenance free Keep it clean to allow for easy visual inspections To clean the Recorder unplug it from the outlet and wipe it with a dry clean cloth A Caution To avoid damaging the Recorder do not use aromatic hydrocarbons or chlorinated solvents
5. for cleaning These solutions will react with and damage the plastics used in the Recorder D4 X Note A non replaceable rechargeable Lithium Battery powers the Recorder clock Do not mix with the solid waste stream A qualified recycler or hazardous materials handler should dispose of spent batteries Contact your authorized Fluke Service Center for recycling information Service The Recorder contains no user serviceable parts Opening the case or attempting to do so will void the warranty and safety certification The USB Cable is the only replacement part in the VR1710 package If service or calibration is required please contact a local dealer or an authorized Fluke service center see Contacting Fluke Software Updates Fluke may periodically offer software and internal firmware updates for the Recorder To download the latest Power Log software or firmware please visit the Support page at www fluke com Specifications Electrical Specifications RMS voltage channels 2 RMS voltage measurement range 70 V to 300 V RMS voltage resolution 0 125 V RMS voltage uncertainty 0 5 of range 300 V Measuring method True RMS Sampling frequency 32 kHz Frequency range 50 1 Hz 60 1 Hz Frequency uncertainty 0 02 Hz Transient recording resolution 12 bit Harmonic amplitude uncertainty 0 1 relative to fundamental RMS value Maximum harmonics recording order 50th Shop for Fluke prod
6. he Recorder and the Windows New Hardware Wizard appears To complete installation follow these steps 1 Select the Install the software automatically Recommended option by clicking Next 2 Click Finish For the latest Recorder firmware see Firmware Updates Adjusting Recorder Settings with Power Log Before using the Recorder to collect data desired variables must be set in the Recorder with Power Log To set these values 1 Connect the Recorder to the PC 2 Launch Power Log Note that the Select Serial Port menu shows Fluke VR1710 If it is not showing click the right arrow on the list and scroll down to it If Fluke VR1710 does not appear in the list leave the Recorder connected and close then re open Power Log Fluke VR1710 should now appear in the list File Edit view Tool eros COM2 a fbx001 bmp Figure 2 Power Log Drop Down List Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 Voltage Quality Recorder Using the Recorder 1 3 Click on vd VR1710 Settings From the Settings screen you can specify the recording interval dip and swell thresholds for triggering Events or erase the Recorder s memory 4 Enter the desired settings and press Apply If Apply is not pressed the Recorder reverts to its previous settings Note Each time that Settings is opened recording data stops and will not restart until the Recorder is plugged in again The percentage of reco
7. hinetlvaiesedeoasackedaasadcodesdeid Svsaeadadeaabeateenaueseeds Recorder SCtUD ci zec scesssaieccdcaces devuscisnesedeesleeddnssacenseedecenieaeteideedeadsadbees taaecestd Loading Power LOG cassnnsuiesssiesvaven ea dag aazoenvan sa beud soatecauamearcaveneares Loading the USB Driver 200 ccccccccccsseeseesteceseceseceseseeesseeeeseeeseesseeeseeeaaes Setting the Time and Date ccc ccccccceseceseceseceeeeeeeeeeeeeeeeeeseeeseeesseeeeesaees Connecting the Recorder for the First Time ccecceseseeceeeeeteceeeeeeeees Adjusting Recorder Settings with Power LOg ccccsseeseeteceteeeteeeteeees Data Coll ctioN sssri acess sons cavenstedxeas eer erena RETTE EEE RESENSEER Downloading and Analyzing the Data with Power Log Maintenance SOL VICE anioia netere E ENRE NEE ENE iN AEEA De a SE ea Ea ESAE EERE ANEA Software Updates 2 cvdciasseaieusaersgivdbantdal bons RE EEEE EES SPOCHIGATIONS shc cccsec ssessates beeibncsuaeiunebvaneme A E aa E A EENE AEE NA EEEE NNS Electrical Specifications sisenes iie a E s General SpecifiGations srastao ineine ieiki kE Eek e R nE SNE Environmental and Safety Specifications cccccesceseceseceseceeeeeeeeeeeeeeeeeees i Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 VR1710 Users Manual il Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 List of Tables Table Title Page 1 SVMiDOIS se psscaveedsacbsud codecs ent acaspdin A ews densab
8. iad dates sdeagaeeadcdassbaandes bl iii Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 VR1710 Users Manual iv Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 List of Figures Figure Title Page 1 VR1710 Voltage Quality Recorder ceccesccescsseceeeceeeeeeeeeeeecssecsseceaeenseenseenes 2 Power Log Drop Down List ccccccesccesscesseseeeseeeseeeseecseecsaecaecnaeenseceseeneeeeeeeeeateass 3 SINA S correo aee o EEE EE ibaa deste tedectatuuleaniagices v Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 VR1710 Users Manual vi Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 Voltage Quality Recorder Introduction The Fluke VR1710 Voltage Quality Recorder the Recorder records and stores voltage trend data from a working power outlet Once the logging parameters of the Recorder have been set via Power Log software the Recorder collects data that can be downloaded to a Personal Computer PC for complete analysis The advanced design ensures accurate recording of all voltage parameters Recorder and Power Log features include Configurable recording interval Graphical and spreadsheet data summaries Min Max Average RMS values with time stamps Transient waveform recording Individual harmonic values and time plots Download recorded data to PC via USB cable supplied Print tables graphs and comprehensive f
9. og uses the PC s internal clock for time and date references It is very important that your PC s time and date are set correctly before running Power Log To set your PC s internal clock e For Windows XP systems set the date and time from the Control Panel e For non XP systems information about setting the date and time can be found in the Windows User s Guide Note If your PC s internal clock switched from daylight savings time to standard time or vice versa during the period that the Recorder is capturing events you should correct the start time and the end time if date and time indicated of the events that occurred up to the time change by adding or subtracting one hour Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 VR1710 Users Manual Connecting the Recorder for the First Time The Recorder plugs into a standard power outlet and connects to a PC via the included USB cable It should be placed where it can be easily unplugged Use the proper adapter included for your country s power type 1 Plug the Recorder power cable into the power outlet Note Do not run Power Log until the recorder is installed and the recorder is plugged in and connected to the PC Power Log will not recognize the Recorder if launched before the Recorder is connected 2 Connect the Recorder to the PC with the USB cable 3 When the Recorder is connected to the PC for the first time Windows finds t
10. ormatted reports View print and export data Please refer to the Power Log Users Manual located on the VR1710 Manual CD for more information The manual provides instruction for installation and use as well as general instructions for connecting to Fluke power quality instruments Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 VR1710 Users Manual Contacting Fluke To contact Fluke use one of the following telephone numbers USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 3 3434 0181 Singapore 65 738 5655 Anywhere in the world 1 425 446 5500 Visit Fluke s Web site at www fluke com for service and calibration information Register the Recorder at http register fluke com Safety Information A Warning identifies conditions and actions that pose hazard s to the user a Caution identifies conditions and actions that may damage the Recorder A AWarning To avoid electrical shock or personal injury when using the Recorder follow these guidelines Read this manual before use and follow all safety instructions Use the Recorder only as described in this User Manual or the safety features provided by the Recorder may be impaired Use only power outlet plug adapters that are supplied with the Recorder Before each use inspect the Recorder for damage Look for cracks or missing portions of it and the cables Do not
11. rding memory used is displayed An estimate of recording time is shown under Typical Continuous Measurement This shows the total amount of time the Recorder can collect data If transients are detected the strored waveforms will shorten the maximum recording time Fluke R1710 Settings i ES Setting Memory Used Recording Interval ds Typical Continuous Measurement Dip Threshold aus y Swell Threshold en4 y Read R1710 Settings Erase Recorded Data Apply Recording starts next time Esnez the VAT 10 is plugged in fbx003 bmp Figure 3 Settings Notes When choosing recording intervals note that shorter recording intervals may mean a shorter period of data is taken before the Recorder storage is exhausted but shorter recording periods result in richer data than if longer periods are used 5 Once the settings are correct click Apply Shop for Fluke products onnea www MY FIUK StOre ca 1 877 766 5412 VR1710 Users Manual 6 Close Settings and disconnect the Recorder from the PC Data Collection The Recorder is now ready to collect data Plug the Recorder into a standard power outlet and it will start recording data based on the settings established in Recorder Setup Leave the Recorder plugged in for a few hours or days depending on your application When you are ready or the Recorder memory becomes full disconnect it from the power outlet and connect it to a PC running Power Log Electric utility spe
12. tional price Fluke reserves the right to invoice Buyer for importation costs of repair replacement parts when product purchased in one country is submitted for repair in another country Fluke s warranty obligation is limited at Fluke s option to refund of the purchase price free of charge repair or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period To obtain warranty service contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect misuse contamination alteration accident or abnormal condition of operation or handling including overvoltage failures caused by use outside the product s specified rating or normal wear and tear of mechanical components Fluke will provide an estimate of repair costs and obtain authorization before commencing the work Following repair the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges FOB Shipping Point THIS WARRANTY IS BUYER S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OT
13. ucts online at WWW MyFl u keSto re ca 1 877 766 5412 VR1710 Users Manual 10 General Specifications Internal memory capacity More than 3 months under normal conditions Communication USB 1 1 and 2 0 Internal clock error lt 1 second month Power consumption 2 5 W Power requirements 70 V to 300 V Size H x W x L Weight 1 5 x 3 x 5 2 in 39 x 77 x 134 mm 0 45 Ib 207 kg Environmental and Safety Specification 77 Operating altitude 2000 m IP rating Vibration requirements Drop test requirements 40 indoor use only Class 2 MIL PRF 28800F im Operating temperature 14 F to 122 F 10 C to 50 C Storage temperature 4 F to 140 F 20 C to 60 C Operating humidity without condensation 32 F to 86 F 0 C to 30 C Max 95 RH 86 F to 104 F 30 C to 40 C Max 75 RH 104 F to 122 F 40 C to 50 C Max 45 RH Measurement category rating 300V CAT II Pollution degree II Safety IEC 61010 1 EMC IEC 61326 1 Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412
14. ug US shown USB Cable port Type B end Figure 1 VR1710 Voltage Quality Recorder Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 Voltage Quality Recorder Using the Recorder Using the Recorder Using the Recorder can be summarized in the following steps 1 Recorder setup 2 Data collection 3 Downloading and analyzing the data with Power Log These steps are explained in more detail in the following sections Recorder Setup The Recorder must be set up prior to data collection The following sections explain the necessary procedures Loading Power Log Before using the Recorder Power Log software and the VR1710 USB driver need to be loaded onto a PC The VR1710 Product CD contains both items as well as an easy to use interface to load the software and manuals to a PC For detailed Power Log installation instructions see nstalling Power Log in the Power Log Users Manual also located on the VR1710 Product CD Loading the USB Driver To load the VR1710 USB driver 1 Run the VR1710 Product CD ona PC 2 Click on VR1710 USB Driver Installation 3 Either select the default directory by clicking on Install or click Change Install Location and change the file path to a different location The necessary files are copied to the PC 4 Restart the PC to conclude driver installation Setting the Time and Date When retrieving data from the Recorder Power L
15. y Do not mix with the solid waste stream A qualified recycler or hazardous materials handler should dispose of spent batteries Contact your authorized Fluke Service Center for recycling information Standard Equipment The following items ship with the Recorder e Voltage Recorder with attached 9 inch 23 cm power cord e Set of six IEC female power adapter plugs for worldwide use o Type B Americas Central America Japan Type F Europe Type G UK Ireland Malaysia Singapore Type I Australia Type J Switzerland Type L Italy North Africa e USB A B cable compatible with both USB 1 1 and 2 0 transfer rates O O O 0 Shop for Fluke products online at WWW MyFl u keSto re ca 1 877 766 5412 VR1710 Users Manual e Product CD including o The VRI710 Users Manual English French Italian German Spanish Portuguese and Simplified Chinese o Power Log Users Manual o Power Log Software o VRI1710 USB driver e Printed multilingual Warranty booklet same languages as above e Certificate of Calibration Practices The Recorder at a Glance Figure 1 shows the Recorder features fbx001 eps Number Description Recording indicator Flashing The Recorder is presently recording information Steady The Recorder has paused and is not recording information Memory full indicator The Recorder s memory is full and needs to be downloaded before taking more readings Power Cable Adapter Pl

Download Pdf Manuals

image

Related Search

Related Contents

Honeywell The Series 7020 Dissolved Oxygen Analyzer User Manual  Sony 263 User's Manual  TV TOOLSDigital Signage  TIPPMANN® - Paintball Gun Manuals  User Manual  PROFESSIONAL COLOR CARE  Navman Marine  Smeg C9GVXI cooker  Cisco Systems IE 3000 User's Manual  LIFAN LF1.5WP-25 Instructions / Assembly  

Copyright © All rights reserved.
Failed to retrieve file