1. Selecting the COMM port Before attempting to communicate with the TR510s you ll need to select the COMM port Check which COMM port your TR510 Terminal s is are currently connected to and choose the appropriate port on the SETTINGS tab Record mode setting You can use this function to set the TR510 s LED position to be always on IN always on OUT or set by Manual The TR510 will keep the last of LED position even after the TR510 is powered off On the Device List select a device ID and double click it to establish connection with TR510 This frame will display or allow you to change the setting if the TR510 s firmware supports this function This software can check the TR510 understanding that the TR510 is supporting this function or not automatically when you log on TR510 to software Setting up the machine Terminal numbers The TR510 supports two different interfaces RS 232 for single terminal point to point communication with PC and RS 485 for multi terminal configuration the latter requires a special adaptor of CON 485 Single terminal configuration does not require machine number setup Multi terminal arrangement requires a unique machine number to be set for each Terminal in order for the system to work Terminals on the multi terminal network are addressed using their machine numbers Each Terminal must have a unique machine number assigned to it If two different Terminals on the network are assigned to the same value
2. schedule You can enter up to 32 times a day at which the ring relay will be activated Note the TR510 does not have any internal ringer only a ring control relay You must attach an external ringer bell in order to use the ring function see the 7R510 User s Manual for further details To set up the ring table e Select the desired Terminal from the Device List e Click on the RING TABLE tab to open it e Click Upload button to upload the existing ring table data if any the data will be displayed in the ring table sorted in ascending order e Add desired entries by entering new time values anywhere on the unused table lines or modify existing entries by typing over e When finished click the Download button the updated ring table contents will be saved back into the TR510 Ring duration is set simultaneously for all ring table entries to define how long in seconds the ring will sound each time Use the Duration button to setup this value Maximum allowable duration is 255 seconds Several other buttons on the RING TABLE tab provide additional functions e Clear button can be used to erase all data in the ring table This will only erase the data shown on the screen but not from the TR510 s memory To delete all entries from the Terminal s memory o Click the Clear button the contents of the Ring Table will be erased o Click the Download button to update the data in the TR510 s memory e Save and Load buttons allow
3. 8030 An error occurred while resetting the device Please check the device connection again Or try another device 8031 An error occurred while polling device 8032 An error occurred while setting the device display to Desk Mode Please check the device connection again Or try another device 8033 An error occurred while setting the device display to Wall Mode Please check the device connection again Or try another device 8034 An error occurred while getting the current device time mode Please check the device connection again Or try another device 8035 An error occurred while getting the current device duration Please check the device connection again Or try another device 8036 An error occurred while initializing the device s database Please check the device connection again Or try another device 8037 An error occurred while preparing the device for data recovery Please check the device connection again Or try another device 8038 Please check the device connection again Or try another device 8039 Second must be between 1 and 59 8040 Terminal database is empty or malfunctioning 8041 Time that you entered is invalid 8042 Date that you entered is invalid 8043 The database is malfunctioning The data could not be loaded 9100 Success 9101 E rror 9102 Not Unit Found 10
4. If this is you first time to connect TR510 then you must set a new ID with the Device Selecting the Terminal Double clicking on the Terminal name in the Device List enables communications with the designated Terminal Communications with the Terminal is not established until you select it by double clicking If you only have a single Terminal connected to the PC you can double click on 000 default Never use 000 default if you have more than one TR510 connected to the PC Setting up time and date Each TR510 Terminal must be set to correct time and date To do this e Double click on the desired Terminal in the Device List all buttons on the SETTINGS tab will be enabled e Click the Set Time the Set Time and Date dialog will appear e Set the time and date using one of two options o Just type in new values and click OK or o Click Syne Synchronize to set the time and date from the computer s clock Setting up display mode The TR510 can be used as a wall mount default or desktop device When used as a desktop device it must be rotated to allow for convenient display viewing angle The text on the LED display must also be rotated 180 Display mode setting allows you to do this e Click the Display button Display mode dialog will appear e Select the desired display mode desk or wall and click OK Setting up the ring table and ring duration The ring table feature of the TR510 allows you to define a daily ring bells
5. TR510 Control Center for Windows 5 User s Manual Help us improve our documentation Send your comments and feedback to gigatms ms3 hinet net Rev A_2 04 15 2002 amp PROMAG Table of contents TADIE OF COMMIS Aeara TEE ETE dete E EE EEE EET 2 Usine th TRS10 Control Center Jeban e are a aa aaeoa E S a S Eo SE RISS 3 System Requirements os e ree e a a ea Aae n aE EEIE SENESE EPES ESS 3 JETE Ln CO n ROEE cashes REEE EAE TEE EE E E OOO E 3 Running the TRS 10 Control Center irrien setetssasoevisshsssekssesteteavhssistaveenssoesds ra E SEESE eao DEEI sse 3 Selecting an Sia ge aer aaraa eea i epar eaea EESE ap Eea I EAEE a Ea E EEE Eo sa OERS ROE EEEa TEREE 4 Selecting the COMM port saer e arre t ea ai sscestes techssdessss sees dssyss sobssectetspokaetsSsvesbestavassaptucesseseseeicsnssoeve s 4 Record Mode Setting e a a E aeea ean R a aE aaa A EE E Aaa RERE 4 Setting up the machine Terminal numbers esesseeseeeeesesreessrerrsserrrststreresrenresrrrrssenrssrerrssesrenreset 4 Setting up the IP address when you connect TR510 to DS100 sssssssssssrrsssrrerserrrrsrrrererree 5 Selecting the Terminali esensina davies jesusessentuceescstevesces tg chaste ieeseet EEES esse Ehe SETER EE NE ISSE EEEE 5 Setting up time and Wate siessen sser ea epror aea eisern Ee E EEEE Ea TE EEEE eE taah SEEE aKa TESES Ee 5 Setting up display Modez a a Ea EE e E T oaoa E EE EE EE E 5 Setting up the ring table and ring duration sssesses
6. abase contents The Database button allows you to delete the database contents initialize the database or perform a database recovery Both options also repair the database Use these functions to restore the normal operation of the corrupted database Err5 on the TR510 s display Note that the TR510 Control Center has no way of knowing whether the database is corrupted or just contains no records in either situation the database will appear to be empty You can verify the database status by attempting to add the record by reading the User card on the TR510 If the record is accepted then the database is OK If Err5 is displayed then the database is damaged and needs repair Repairing the database by initializing it makes it immediately available for use However existing records in database will not be retrieved and saved Database recovery gives you a chance to retrieve these existing records After the recovery the database appears to be 100 full with records Some of these records may be invalid Expect to retrieve some percentage of invalid data The records you are interested in could be overwritten by newer ones at the time of attempted recovery Hint the TR510 also features a power on auto recovery mechanism Follow this procedure when you get the Err5 message e First try to switch the TR510 off and on again the Terminal will attempt to auto repair the Err5 condition automatically e If this fails i e you still cannot add n
7. ce ID and double click to update device information into software Time scheduler will use YYYYMM TXT for standard version or MM YYYY TXT for OEM version as the default file names If you wish to use other file name you can use Change save path button to change If you don t rename file name by Change save path then software will use the file name that you used last time to save all records Therefore if you want to save all records into another file during time scheduler running then don t forget to change file name by change save path button An event file will also be created to record the events performed by Time Scheduler Such events will include the start time of the Time Schedulers and the TR510 terminals that have been polled Software will save all events to a file named eventyyyymmdd txt in the events folder Press Start Button to start Time scheduler when you have performed the above steps for the TR510 s settings At the scheduled time Time Scheduler will detect device according to the device list If TR510 s settings are correct and are connected to the PC with power on then the software uploads and save the records from TR510 s automatically Appendix Creating new language resource file The TR510 Control Center allows for easy localization through language resource files When the TR510 Control Center is installed it creates a sub directory named Language in its working dir
8. e must be between 1 and 59 8015 The value you entered is notnumeric Please try again 8016 Time or date is incorrect 8017 Duration must be between 0 and 255 8018 No data is entered Please choose your option 8019 The device failed to reply to the computer s command Either the device is currently offline or you have selected the wrong COMM port 8020 The device failed to reply to the computer s command The device is either currently offline or having connection problems 8021 Do you know that you have 8022 records in the database Are you sure that you want to initialize the database 8023 records in the database Are you sure that you want to recover the database 8024 An error occurred while disabling ring table entries Please check the device connection again Or try another device 8025 An error occurred while setting the ring table entries to the device Please check the device connection again Or try another device 8026 An error occurred while enabling the ring table entries Please check the device connection again Or try another device 8027 An error occurred while uploading the time entries from the device Please check the device connection again Or try another device 8028 An error occurred while checking the ring table entry activation Please check the device connection again Or try another device 8029 An error occurred while getting time from the device Please check the device connection again Or try another device
9. ectory Unless you have chosen a different installation directory the TR510 Control Center is installed in C Program files Giga TMS TR510 Control Center Language sub directory is found inside After the installations this sub directory contains resource files for already supported languages To create a new resource file e Create a copy of the file named English txt in the same sub directory but under a different name Never edit English txt itself make a copy under a different name and edit this copy instead e The filenames of the files is what is displayed in the Language drop down box on the SETTINGS tab of the TR510 Control Center Therefore the name of the file you are creating should reflect the actual language supported i e Korean txt Spanish txt etc e Open the file using the Notepad or any other suitable ASCII text editor e The file consists of lines in the following format ID text ID is the numerical ID that uniquely identifies the string resource Make sure that you don t change it Replace the English text after the equal sign with its equivalent in the language you are creating the support for Do this for every line in the language resource file e When done save the file and run the TR510 Control Center again Choose the language you ve just created it should be visible in the Language drop down box e Check the results of your translation and make adjustments if necessary F
10. esssseeseseeeseserersstsresrrsreerssreresesrenrerrnertenesrenresreerset 5 Retrieving and saving the Time and Attendance data eeceeceseceseceeceseceecesecseecaeseneseeeeeeeeeeenes 6 Erasing or Recovering the database contents sseseessesseseseseresssreersseerrsststesrestesteseerreserrreesrenreseeersee 6 Res iting the TRS O sine es Reni ak aeae AEE E e EE 7 Setting Time Sch d ler sse se tee iin Shes eee te cee ih ate aM Ate al eae 7 Appendix Creating new language resource file eee eee cee cece cneeceeeeeeeseeeeeeseeeseesecsaecsaecsaecsaeenaenaes 8 Using the TR510 Control Center The TR510 Control Center software is a simple and easy to use program that allows you to access the TR510 Time Recorders online and setup the function parameters Settings as well as download and save the Time and Attendance data collected by each Terminal System Requirements The TR510 Control Center software runs under Windows 95 98 2000 NT At least 7MB free disk space is required on hard disk drive HDD Recommended RAM size is 32MB Installation To install the TR510 Control Center run the 7R510 exe file from the enclosed software CD Simply click on the Install TR510 Control Center for Windows link on the CD s title HTML page runs automatically once you insert the CD into the CD ROM drive After you click on this link a File Download dialog will open Choose Run this program from its current location and click OK A Securi
11. ew ID 701 Select ID address download to TR510 800 Time and Date 801 Sync 802 Synchronize TR510 time date with PC 803 S et duration 804 Initialize the database 806 P repare for Data Recovery 809 nter desired ring time 811 Display 812 Set display mode 814 Display mode 815 Manage database 816 Choose the display mode of TR510 817SInitialize will clean the machine s record database Data recovery will prepare the machine s record database in such a way that you might manually recover some useful information which is otherwise lost Because of the side effects of the recovery action an initialization is necessary after a recovery is taken place Please make sure that these actions are necessary before you take any action 818 Are you sure that you want to reset the device 820 Wall Mode 821 Desk Mode 822 ID Digital Set 823 Relay Control Mode 824 F or Alarm 825 F or Door Lock 900 T S 901 Start 902 Stop 903 Change path 904 No 905 Hour 906 Min 907 Time scheduler is running Pls stop it and login device again 2000 S ettings 2001 Ring Table 2002 R ecords 2003 Time Scheduler 8008 Communications with TR510 failed 8009 P lease set the device in LOGIN mode then try again 8010 P lease check your Device ID selection 8011 Please check your COMM port setting and make sure that your device is at the right port 8012 P lease check the data parameter then try again 8013 Hour must be between 1 and 23 8014 Minut
12. ew records to the database and cannot load the database contents then perform the database Recovery Both Initialization and Recovery functions are accessed by clicking on the Database button You ll be requested to enter the password use either 0000 or GIGA keep the passwords confidential so no unauthorized person can delete the data The Manage Database dialog will appear after the password entry Choose your option and click OK If you ve chosen recovery then the Records tab will display a large number gt 8000 of new records click Upload to load the data Reseting the TR510 The TR510 may be reset to the default factory settings by clicking on the Reset button SETTINGS tab Note reset will actually take place on the next TR510 power up Reset operation will Initialize the Terminal s machine number to 0 Set display mode to Wall Clear the ring table Initialize the ring duration to 10 seconds Check the time and date and initialize it to 01 01 2000 00 00 00 only if time date was invalid Reset operation will not affect the records stored in database Setting Time Scheduler In this tab software provides 32 settings for Time scheduler to download records from all the powered on TR510s that are connected to PC and displayed on device list IMPORTANT Connections must be established with all the TR510 from Settings tab and a unique number must be assigned to each terminal not include 000 First select the devi
13. ollow are the original contents of the English txt file 1 TR510 20 Arial 21 9 40 Record mode 50 Manual 51 Always OUT 52 Always IN 101 Device List 102 Click to poll 103 Device Name 104 Com Port Select 107 Status 112 Add 113 Add Address 114 Delete 115 Delete Address 116 Set M 117 Assign new ID 118 The password is incorrect 120 Set Time 121 SetTR510 Time 124 R eset 125 Reset will take place after you switch the Terminal off and back on again 126 Event 127 Set event select mode 131 Clear 132 Clear ring table 137 Bell duration 0 255 sec 140 Y ou haven t finished uploading the records are you sure that you want to save the data and initialize the database anyway 201 lease enter date mm dd yyyy 202 lease enter time hh mm ss 206 Save 207 Save Ring Table to file 212 Open 213 Load Ring Table from file 301 N0 302 Hour 303 Minute 304 Duration 305 Set Bell duration 306 Save 307 Save record to file 319 Upload 320 Upload ring table from TR510 321 Download 322 Download ring table to TR510 401 NO 402 Card No 403 Event 404 Date 405 Time 406 Database 407 Initialize or recover TR510 database 408 Upload 409 Upload record from TR510 412 Sort Asc 413 Arrange Data in Ascending Order 414 S ort Des 415 Arrange Data in Descending Order 417 Open 418 Load record from file 500 Not Unit Found 600 P assword 601 P lease Enter Password 602 0k 603 Cancel 700 Assign n
14. t have the 10 terminal only limitation so you can use it to set up bigger networks To assign the machine number using the TR510 Control Center e Connect all TR510 Terminals you are planning to use to the PC one by one i e one at a time and repeat the following steps for each Terminal o Double click on the 000 default item in the Device List The Terminal will be selected and all buttons on the screen will be enabled o Click the Set M button the Assign New ID dialog will appear o Choose the Terminal number name from the drop down box and click OK The Terminal s Machine number will be set to the selected value e Put all Terminals back on a single network and make sure that you can communicate with every Terminal by double clicking on each entry in the Device List except the default one If the software cannot communicate with the selected Terminal an error message will display NOTE The most common problem for multi terminal configurations is the conflict between the terminal numbers Always start by checking the Terminal numbers of each Terminal when attempting to resolve communication problems that is after making sure all Terminals are on Setting up the IP address when you connect TR510 to DS100 Click on the Terminal 0 Default in the Device List then set IP address Which you set to DS100 on the IP text box When setting is done you can Double click the Terminal 0 to logon the device with the TR510 Control Center software
15. then there will be a conflict on the network and these Terminals will be inaccessible from PC Each Terminal on the network is represented by separate entry in the Device List SETTINGS tab After the software installation the list contains only one entry 000 default 000 is a so called universal machine number use it only if there is ONE Terminal If there are more than one Terminal it is necessary to create separate entries for each Terminal on the network Click on Add button several times if necessary to add entries to the Device List For example if your network has 4 Terminals then your list should have 5 entries including the 000 Default entry as shown on Fig above Each entry consists of a machine number and a Terminal name Machine numbers are created in ascending order Numbers cannot be skipped i e you cannot create Terminal 1 2 amp 4 Terminal names can be edited To do so select the entry in the Device List and enter the new name in the Device name text box After the necessary number of entries has been created you must set the machine number of each Terminal There are two ways of doing this e Use the Terminal s IN and OUT buttons to set the machine number refer to the TR510 User s Manual for more details e Use the TR510 Control Center to set the machine number The first method is easier but only allows you to set the numbers in the 1 10 range The second method is somewhat more complicated but it doesn
16. ty Warning will appear at this point just click Yes to continue the installation The WinZip self extractor dialog will appear next click Install and follow the installation instructions on the screen Running the TR510 Control Center By default Control Center icon is created in the Start Programs Giga TMS folder After the program startup the main screen will appear FA Time ME Tool LITE 15 x Settings Ring TableTabs Records Time Scheduler Device List 000 Defautt oo 001 Machine 002 Machine a ONAMarhina Terminal Com PortSelect Com Port Select List ps100v2 Guo macrine ees glis 007 Machine IP Language Select NNO Machina rp text box Add Delete Set hime Display Main screen contains four tabs e SETTINGS to set up basic function parameters e RING TABLE to edit the ring schedule e RECORDS to upload and save the TR510 s Time and Attendance database contents e Time Scheduler to set up time for auto uploading the records from all TR510s that are connected to PC Selecting language The TR510 Control Center can support multiple languages through its language resource files The language drop down box on the SETTINGS tab displays all available languages Choose the language you want to use and all text strings will be changed accordingly If the desired language is not available a new language resource file can be easily created see Appendix for more details on how to do this
17. you to save the contents of the ring table to the disk file on your PC Retrieving and saving the Time and Attendance data The third tab RECORDS contains all the necessary controls to upload the database data from the TR510 into the PC and to perform database maintenance To upload the data e Double click on the desired Terminal in the Device List e Click on the RECORDS tab e Click Upload to upload all Time and Attendance records from the TR510 into the PC e During the uploading process the progress bar below the data table displays the task progress and the total number of records to be uploaded e Uploaded data will be displayed in the data table in the following format o The NO field record numbers o Card No field D code of the ID card o Event field 0 OUT 1 IN o Date and Time fields date and time of record creation e Click Save to save the uploaded data into the disk file Default filename offered is a string in the following format yyyymmad txt year month date e Once the data has been safely saved into the file the data in the TR510 s memory is erased automatically e The Software will attempt to open the saved data in the Notepad if the data is too big for the Notepad then in the WordPad Both are standard Windows text editors that normally come with every Windows distribution Note there is also an Open button that allows you to load the disk file contents into the data table Erasing or Recovering the dat

Download Pdf Manuals

image

Related Search

Related Contents

    Hotel Receptionist User Guide  Manuel d`Utilisation  Samsung 29A11 CRT Television User Manual  DE EN FR IT BETRIEBsaNlEITuNg usER`s MaNual MoDE D`EMploI  Le traducteur professionnel face aux textes techniques et à la    High-level Best Practices  Ensayo en laboratorio de la abonadora Vicon Rotaflow RS-M  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.