Home
User Manual
Contents
1. LED WAV 50W User Manual Please read the instructions carefully before use TABLE OF CONTENTS 1 Safety Instructions 2 Technical Specifications 3 How To Set The Fixture 4 How To Control The Fixture 5 DMX 512 Configuration 6 DMX 512 Connections 7 Troubleshooting 8 Fixture Cleaning 2A WARNING 1 Safety Introductions A N Please read the instructions carefully which includes important information about the installation operation and maintenance Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet All fixtures are intact from the manufacturer please operate follow up the user manual artificial fault are not under guarantee repair Unpack and check carefully that there is no transportation damage before using the unit The unit is for indoor use only Use only in a dry location Do install and operate by operator Use safety chain when fixes the unit Don t handle the unit by taking its head only but always by taking its base The unit must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked otherwise the unit will be overheated Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit Its important to ground the yellow green conductor to earth in order to avoi
2. and Mode function 5 DMX output For DMX512 link use 3 pin XLR plug cable to link the next unit DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal Mains input Connect to supply mains power for the unit Mains output Connect and supply mains power for the other unit 9 cooling system for cooling down the unit 3 2 Installation A Product Items User manual 60lens B Mounting You can install the unit on the truss or ceiling Use clamps to fix the unit to truss Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure Also always use a 6A safety cable that can hold 10 times of the weight of the unit when installing the fixture C Replace the lens You could replace the other lens if you want to as following picture You should screw the lens roller to take it down as NO 1 and bring the lens out as No 2 Then you could replace the lens that you want to Notes the lens roller has two slots for the lens you should pay more attention that the latest slot is for the 34 lens and the far slot is for 60 lens To select any functions press MENU button until the required one is shown on the display Select the function by ENTER button and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it wi
3. control the other to give an automatic and synchronized light show This function is good when you want an instant show Any fixture can act as a Master or as a Slave 4 2 Easy Controller by CA 8 The easy remote control is used only in master slave mode By connecting to e the 1 4 microphone jack of the first unit you will find that the remote controller P on the first unit will control all the other units for Stand by Function and Mode Color speed 1 3 Mode LED OFF LED ON LED blinking selection Blackout To blackout all the fixture Hold and press for 3 seconds Function Water wave speed 1 3 1 Clockwise counterclockwise color 2 choose color 4 3 DMX Controller Use universal DMX controller to control the units you have to set DMX address from 1 to 512 channel so that the units can receive DMX signal Press the MENU button up to when the Hadr js showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX512 address Once the address has been selected press and keep ENTER button pressed up to when the display stops blinking or storing automatically one minute later To go back to the 11A functions without any change press the MENU button again If you use please refer to the following diagram to address your DMX512 channel for the first 4 units oe R m w m ata Pata S55 3 i ee ae o D A id y o
4. nnels U 5 channels e A ARN O o o AN ES N Mg 2k 86 PIO J NAS os 4 a8 a Of avs n ee UTA b Be EEE Nea gt kd BAS 95 s FAN rca s s Jaro 3s et NAYS i 8 DA re S AREETA 25 CSB oma J F 5 Sy gt o 1 an amp y o o o 7 L DMX512 Configuration 3 CH mode COMMON LNA Dimmer Effect Color UMA INPUT Oh OL TPL T Lith 255 100 000 009 Blackout 000 007 Termination reduces signal errors and avoids signal rasan ae transmission problems and interference Itis always maran advisable to connect a DMX terminal Resistance 120 ohm 1 4W between pin2 DMA and S lopped 128 186 Fast to slow Pin3 DMA ofthe last fixture Clockwise 1 Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y 135 245 Slow to Fast 167 196 Antichockwise cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 246 255 S topped AE 2 The DMX output and input connectors are pass through to maintain the DMX circuit Anticlockwise when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug
5. d electric shock Maximum ambient temperature TA 40 C Don t operate it where the temperature is higher than this Don t connect the device to any dimmer pack First run there will be smoke or smells and all disappearing a few minutes later Make sure there are no flammable materials close to the unit while operating as it is fire hazard Look over power wires carefully replace immediately if there is any damage Never run on for a long time lest shortening lifespan Avoid any inflammable liquids water or metal objects entering the unit Once it happen cut off the mains power immediately Do not operate in dirty and dusty environment also cleaning fixtures regularly 3A e Do not allow children to operate the fixture 2 Technical Specifications e Do not touch any wire during operation as there might be a hazard of electric shock e Avoid power wires together around other cables e Voltage AC 100 240V 50 60Hz 23 e Disconnect mains power before fuse lamp replacement or servicing e LED 50W LED e Replace fuse only with the same type e Fuse T 6 3A e Inthe event of serious operating problem stop using the unit immediately Power consumption 80 W e Never turn on and off the unit time after time e Dimension 279 x226 x 191 mm gi Jg e The housing the lenses or the ultraviolet filter must be replaced if they are visibly e Weight 4 kg pcs f oT amp damaged I ad e Do not open the unit as t
6. here are no user serviceable parts inside 226 e Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance e Disconnect the mains power if the fixture is not used for a long time 3 1 Control Panel e Do use original packing materials once transport it again e Do not look directly at the LED light beam while the fixture is on For power supply do not connect in series much more than 7 units use another mains supply for next 7 units Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture 9 The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people and has no one pass by or under it Display To show the various menus and the selected functions 4A 5A 2 LED MASTER Master Mode SLAVE On Slave Mode Button To go forward in the selected functions To confirm the selected functions 4 Only for remote control Connecting with CA 8 UC3 to control the unit for Stand by Function
7. it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually O amp 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 6 DMX512 Connections 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels Pin4 5 not used 12A 13A 7 Troubleshootino Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting The fixture does not work no light Check the connection of power and main fuse A 1 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C Some fixtures don t respond to the easy controller o_o You may ha
8. ll automatically return to the main functions without any change after idling one minute Back to the functions without any change press MENU button The main functions are shown below 7A Jdid DMX512 Address Setting Master Slave Mode LED on LED off Normal Inversion MENU Manual test ic Self test Ena Temperature Che Fixture Hours Software Version i i Reset DMX 512 Address Setting Press the MENU button up to when the Addl is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically exit menu mode without any change after one minute Back to the previous functions without any change press MENU button 8A I _ Itt Slave Mode Press the MENU button up to when the Seno is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the HAS set the fixture as master or GL set the fixture as slave Once the mode has been selected press the ENTER button to setup or automatically return to the main functions without any change after one minute To go back to the functions without any change press the MENU button again 15 T Dispiay Inverse Press MENU button until d SF is blinking on the display Use DOWN and UP button to select na display normal or 5 dis
9. o Press the MENU button up to when the rhe is blinking on the display Pressing ENTER button and the display will show the number of working hours of the unit To go back to the functions press the MENU button We Software version Press the MENU button up to when the ber is showing on the display Pressing ENTER button and the display will show the version of software of the unit To go back to the functions press the MENU button again Factory reset all channels Press the MENU button up to when the c 5 Pt is shown on the display press ENTER button to setup Back to the functions without any change press MENU button 4 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram function 2 By easy controller 3 By DMX controller No need to turn the unit off when you change the DMX address as new DMX address 10A setting will be effected at once Every time you turn the unit on it will show CP21 on the display and move all the motors to their home position After that the unit will be ready to receive DMX signal or run the built in programs 4 1 Master Slave Built In Preprogrammed Function The fixture will allow you to link 2 fixtures together and operate without a controller In Master Slave mode the first fixture whose DMX input jack has with nothing connect need to set as master and the other unit need to set as slave 1 via menu then the first unit will
10. play inverse press ENTER button to setup LED display Press the MENU button up to when the Led is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select display always on or oF Fldisplay off 20 seconds after exit menu mode Once select press ENTER button to setup or exit menu mode without any change after one minute Back to the functions without any change press MENU button again T lja Manual setting color Press the MENU button up to when the l J is shown on the display Pressing ENTER button and use DOWN and UP button to select Lolo 0 255 or UMUE 000 2555 clockwise counterclockwise or di A 25 255 press ENTER button to confirm and use DOWN and UP button to adjust the value once select press ENTER button to setup or automatically exit menu mode without any change after one minute To go back to the last function without any change press the MENU button Self test Press the MENU button up to when the be St is shown on the display Pressing ENTER 9A button to run the auto test Back to the functions without any change press MENU button Back to the functions without any change press MENU button Temperature Test Press the MENU button up to when the t ene is blinking on the display Pressing ENTER button and the display will show the temperature of the unit To go back to the functions press the MENU button again E rC I Fixture Hours a
11. ve a break in the DMX cabling Check the LED for the response of the master slave mode signal Wrong DMX address in the fixture Set the proper address No response to the sound Make sure the fixture does not receive DMX signal 2 D 1 2 Check microphone to see if it is good by tapping the microphone E One of the channels is not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 8 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics e Clean with soft cloth using normal glass cleaning fluid B E E Innovation Quality Performance e Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 14A 15A