user manual - sinclair air conditioners

image

Contents

1. USER S MANUAL B d E AIR CONDITIONING NN SONOS US INTRODUCTION TECHNICAL DATA Congratulations on purchasing portable type air conditioner Your air conditioner has been developed and manufactured in accordance with standards of state of the art technology Please read the operating instructions carefully before connecting your unit to the power supply in order to prevent damage from improper use Pay special attention to the safety instructions If you pass this unit on to a third party you must also include these operating instructions Please keep these operating instructions in a safe place for any questions which may arise in future Thank you for showing confidence in our product We hope you enjoy a pleasant room climate with your air conditioner Original instructions EASY TO OPERATE AND TO EASY TO MOVE AROUND The unit can be moved easily on rollers from room to room The air quantity can be adjusted via up to three ventilation levels The air flow can be very strong and reach up to 5 or 6 metres Installation by a specialist is not required Simply plug into a normal household socket with an operating voltage of 220 240V 50Hz The extract air hose can be stored in the unit for transport and when not in use This unit operates in accordance with the heat pump principle On account of the special innovative construction of the unit its heating function is extremely efficient compared to conventional hea
2. Symbol __ Va Un _ Rated capacty tor cooing eestor ig 49 w _ Rated for pening Prated for heating ated powerinputtorcoolng Pen ee Rated Energy efficiencyratio 0 J Rated Coeficient of performance oe LT 2 1 mS Power mode o forcoolng aso Electricity consumption forheating w Enwmydas wating Refrigerant type weight R410A 0 605 kg V Fememy 8 o S EL Hosfohdar lehidamse 12 15 o O EGIT litres day DDmemionsofprdut SOXTIBXSOS mm _ Dimensions ofpackage wma S850x815x3309 mm _ s kg Weightwith package OO 338 M Name and address of the manufacturer or of its authorised representative R410A 50 HFC 32 50 HFC 125 Contains fluorinated greenhouse gases covered by the Kyoto Protocol 14 NOTE CONCERNING PROTECTION OF ENVIRONMENT This product must not be disposed of via normal household waste after its service life but must be taken to a collection station for the recycling of electrical and electronic devices The symbol on the product the operating instructions or the packaging indicate such disposal procedures The materials are recyclable in accordance with their respective symbols By means of re use material recycling or any other form of recycling
3. dehumidify to cooling or heating ERROR CAUSE REMEDY PROBLEM Can switch the No unit on The unit must be placed upright for at least 24 hours immediately after after every transport Otherwise the compressor may be unpacking it damaged and there is no capacity When switching Production related Odour development can arise on first use and after a on the unit sense cause or incorrect longer period of non use by storing in unsuitable areas a smell What storage of unit at e g e g dusty areas should do dusty areas Run the unit for a The smell will disappear after a while In the case of intensive odour development air the No To achieve temperature adjustments surplus heat or coldness must be discharged To use the purpose of the filter fully it should be replaced every 6 months Can operate the unit WITHOUT the extract air hose At which intervals should the activated carbon filtrer of the unit be replaced How can increase the efficiency of the unit External circumstances exist which may impact the efficiency of the unit Room insulation use of wall window adapter ratio of window space solar radiation operation of electrical units in the room EDP presence of several persons in the room You can increase the efficiency of the unit accordingly by adjusting such circumstances Compressor does EN Depending on ambient temperatures and unit type it may not activate
4. expired the unit starts automatically If you press the POWER switch before the time has expired the time programming is deleted The unit switches on and can be operated in the required operating mode Residual time This function is used to automatically deactivate the unit when the time entered has expired Proceed as follows i Press the TIMER switch during operation and enter the required number of hours after which the unit is to switch off ii After the flashing of the number of hours on the LED has stopped you can select the required function cooling heating dehumidification and the required temperature iii When the set number of hours has expired the unit switches on automatically If you press the POWER switch before the time has expired the Timer programming is deleted and the unit switches off SLEEP Using this key you can set the sleep function of the unit The microprocessor integrated in the unit will raise the pre set temperature by 2 C per hour up to a maximum of 4 C after 2 hours and maintain this temperature until the set time has expired If you use the sleep function first set the time switch to the set hours as described in the functions Residual time or Starting time Then press the TIMER switch until the required hours appear on the display After the hour display the display switches automatically to the previous set temperature display To change the temperature press the switch TEMP 4 o
5. outside temperatures do no fall below 7 degrees If the outside temperature should however fall below 7 degrees continuously we recommend indoor operation Connect the air hose and the air outlet grid to the unit as displayed in the illustration or the air hose connection piece and air outlet grid need to be exchanged Set the function to Heating The settable temperature range is between 15 and 25 degrees target temperature You can set this using the temperature control The air with high oxygen content heated by the unit is fed into the room via the air hose This be executed e g via a tilted window a door or wall aperture Make sure that no warm outside air can enter the room For effective heating we recommend our selection of various accessories which reduce or prevent entry of cold air into the room Using the Comfort Control Kit you can also control the unit from inside using the remote control The Comfort Control Kit set is additional accessories It is possible to buy it at the seller or supplier After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for three minutes Cooling effect may require a further 10 minutes Further information is available under the item Troubleshooting DEHUMIDIFICATION Humidity is extracted from the air collected in the water tank and discharged via the condensation water outlet Only air the room if
6. the humidity of the outside air is below that in the inside room Set the function to Dehumidity Caution In the dehumidify mode separate setting of the ventilator is not provided since the lowest ventilation level is already preset to ensure efficient dehumidification of ambient air The rubber plug of the condensation water outlet is removed and a drainage hose attached To collect the condensation water easily in a tank a drainage hose is included in the scope of delivery which you can connect to the upper condensation water outlet Allow water to flow out continuously in order to achieve higher dehumidification capacity In the dehumidify mode you must not feed the room air outside with the extract air hose CLEANING AND MAINTENANCE MAINTENANCE PLEASE REMOVE THE POWER PLUG FROM THE SOCKET BEFORE CLEANING THE UNIT COARSE FILTER The air filters on the side of the unit can be simply removed by pulling the frame sidewards When cleaning use a vacuum Cleaner with brush or wash the filters under running warm water and dry them with a soft cloth Please clean the coarse filters before initial use and regularly when in use ERROR MESSAGES The local air conditioner is equipped with a 3 minute compressor delay system which means the compressor needs 3 minutes to start This affects the switching on of the unit POWER as well as switching over from one function to the next e g
7. d with heating function if the outside temperature is lower than 7 C However you must then ensure that the unit is operated inside and the room temperature is at least 7 C Caution In the heating mode separate setting of the ventilator is not provided since the highest ventilation level is already preset to avoid overheating of the unit HEATING IN INDOOR OPERATION The unit is in the room to be heated Caution Connect the air hose and the air outlet grid to the unit as displayed in the illustration the air hose connection piece and air outlet grid need to be exchanged The cold extract air has to be fed out of the room via the air hose This can be executed e g via a tilted window a door or wall aperture Make sure that no warm outside air can enter the room For effective heating we recommend our selection of various accessories which reduce or prevent entry of cold air into the room Set the function to Heating The settable temperature range is between 15 and 25 degrees target temperature You can set this using the temperature control After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for three minutes Cooling effect may require a further 10 minutes Further information is available under the item Troubleshooting HEATING INOUTDOOR OPERATION The unit is outside the room tio be heated Outdoor operation is ideal for the transition period in which
8. ergy Observe all data in these operating instructions concerning function range New measurement of start temperature Please switch the unit off and start it again after approx 30 minutes If the error occurs continuously the unit requires specialist inspection Temporary error on measuring output temperature Please switch the unit off and start it again after approx 30 minutes If the error occurs continuously the unit requires specialist inspection This error message in the cooling function refers to too high ambient temperatures and in the heating function to too low ambient temperatures Please observe the instructions relating to ideal operation of the unit This may also be a temporary error measurement between the start and output temperature Please switch the unit off and start it again after approx 30 minutes If the error occurs continuously the unit requires specialist inspection If the water tank is full the warning sign E4 appears in the display To restart operation of the unit please remove the plug of the condensation water outlet to allow water to leak out Please use an appropriate collection tank When the water has been completely removed please start the unit again The unit can now be used as usual This procedure is completely normal and protects the system from icing and failure The unit starts automatically after approx 15 minutes again depending on the function setting This procedure re
9. ively up to a minimum temperature of 15 C 5 LED DISPLAY The display shows the required target temperature By pressing the TEMP or TEMP switch the required target temperature is briefly displayed On pressing the TIMER switch the number of hours is briefly shown until activation or deactivation After each manual setting the display automatically shows the required target temperature In the dehumidification function DH is shown in the display Error messages are also shown in the display 5 SPEED Press this switch to set the ventilation speed to LOW MID middle HI high or AUTO automatic If AUTO is selected the ventilator operates at temperature differences larger than 9 degrees at top speed If the temperature reduces to a difference smaller than 4 degrees the ventilator switches to middle blower position If the temperature reduces further until the target temperature the ventilator switches to the lowest blower position TIMER Programmable time switch with start and residual time Starting time This function is used to switch on the unit automatically when the time entered has expired Proceed as follows i Press TIMER switch in Stand by this unit is connected but not in operation to enter the required number of hours after which the unit is to start ii Select the required function cooling heating dehumidification and set the required temperature iii When the set number of hours has
10. old appliances you are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal station is located INFORMATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label Hermetically sealed system The value GWP 2088 GWP Global Warming Potential In case of quality problem or other please contact your local supplier or authorized service center Emergency number 112 PRODUCER Producer SINCLAIR CORPORATION Ltd 1 4 Argyll St London W1F 7LD UK www sinclair eu com This product was manufactured in China Made in China REPRESENTATIVE AND TECHNICAL SUPPORT NEPA spol s r o Purkynova 45 612 00 Brno Czech Republic Tel 420 800 100 285 WwwW nepa CZ 15
11. peats itself regularly Please switch off the unit to STAND BY mode by pressing the button POWER on the unit the unit is plugged in Hold for 5 10 seconds button FUNC on the unit and after a beep sound switch on the unit by button POWER 11 WIRING DIAGRAM REMOTE REMOTE DISPLAY RECEIVER TEMP SENSOR YELLOW ENERGY LABEL 1 2 kwni amp min 1 0 kwh amp Omin EMERGIA Ek PTHE EMEPTEIA ENERGY ENERGIE ENERO 626 2011 4 2 3 1coe 1 9 kwni amp min 1 3 kwri amp Omin ENERGIA EMEPPTEIA EMER DA ENERGY ENERGIE EMER Aa amp 26 2011 12 TECHNICAL PARAMETERS Model name AMC 11AN Rated capacity for cooing 30 w _ ReedEnemyefidenyraio Rated Coefcient ofperformance o Electricity consumption for neatins Qs 08 wah _ __ coma AlAe oo V Frequency 8 H 2 Rasgar 88 A Demmi OSS n _ Wegwofpodud SSS S S kg weight with packages M Name and address of the manufacturer or of its authorised representative R410A 50 HFC 32 50 HFC 125 Contains fluorinated greenhouse gases covered by the Kyoto Protocol 13 TECHNICAL PARAMETERS Model name AMC 14AN Description
12. prevent entry of warm air into the room Place the function to COOLING Set the target temperature using the temperature control The settable temperature range is between 17 and 30 degrees target temperature The unit must only be used in an ambient temperature of maximum 32 C Note After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for three minutes Cooling effect may require a further 10 minutes Further information is available under the item Troubleshooting COOLING IN OUTDOOR OPERATION The unit is outside the room to be cooled Connect the air hose and the air outlet grid to the unit as displayed in the illustration the air hose connection piece and air outlet grid need to be exchanged Place the unit in the shade if possible and in a cool place in order to increase efficiency and to avoid overheating At an ambient temperature of over 32 degrees the unit may deactivate If this occurs continuously we recommend you temporarily use the INDOOR OPERATION of the unit We recommend that a drainage hose for condensation water be connected lt lt Set the function to COOLING The settable temperature range is between 17 and 30 degrees This can be set using the temperature control The air with high oxygen content cooled by the unit is fed into the room via the air hose This can be executed e g via a tilted window a door or wall aperture Make su
13. r TEMP With each press on the switch the temperature increases or decreases by 1 C lt lt COOLING It is recommended to start the unit early on hot days thus avoiding heating up of the room This unit has a self evaporation function for condensation water so that it is normally not necessary to empty the water tank in cooling mode The drainage hose need not be connected Please make sure that the outlet is closed with the rubber cap during operation This does not apply in the case of high air humidity If the unit operates in cooling mode for a longer period and especially at a time of year with high air humidity the condensation tank may be full The control lamp will remind you to empty the water Refer to error message E4 In such a case empty the water tank via the condensation water outlet If continuous high air humidity is likely it is recommended to drain the condensation continuously via the drainage hose COOLING IN INDOOR OPERATION The unit stands in the room to be cooled Connect the air hose and the air outlet grid to the unit as displayed in the illustration the air hose connection piece and air outlet grid need to be exchanged The warm extract air must be emitted from the room via the air hose This can be executed e g via a tilted window a door or wall aperture Make sure that no warm outside air can enter the room For effective cooling we recommend our selection of various accessories which reduce or
14. re that no warm outside air can enter the room For effective cooling we recommend our selection of various accessories which reduce or prevent entry of warm air into the room or via the remote control Using the Comfort Control Kits you can also control the unit from inside using the remote control The Comfort Control Kit set is additional accessories It is possible to buy it at the seller or supplier After switching on or over the ventilator operates but the compressor only starts after the control lamp has flashed for three minutes Cooling effect may require a further 10 minutes Further information is available under the item Troubleshooting HEATING On cold days it is recommendable to start the unit early in order to avoid intensive cooling of the room For the heating function and to improve the heating effect and avoid lower temperatures lower than 17 C we recommend you remove the rubber plug from the condensation water outlet and allow the condensatation water to leak out of the unit using the drainage hose However the drainage hose does not have to be connected in the heating mode Please make sure that the condesnation water outlet is closed with the rubber cap during operation In such a case proceed analogously to the emptying of the water tank in the cooling function The heating function of the unit must not be operated at a room temperature of more than 23 C or less than 7 C The unit can also be operate
15. take approx 10 minutes after starting the compressor until the cooling heating capacity is reached unit deactivates How is the m or m data of the manufacturer calculated On reaching the set required temperature the unit switches off automatically Check manual setting of the required temperature as well as the TIMER setting The m or m data of the manufacturer for the various units are average values related to a room height of 2 5 metres It must be considered that such data can be clearly underscored or exceeded under certain circumstances Circumstances which work against efficiency of the units include e g bad insulation of the building large window areas south facing attic apartment many additional heat sources such as e g number of persons EDP light kitchen units washing units etc Unit does not cool correctly Switching the units from F to C and viceversa Room temperature outside the function range Room temperature inside the function range Temperature of the cooling agent lines too high or too low Incorrect signal Water tank full Defrosting mode You achieve the most effective and economical cooling comfort if you already cool the room to be cooled when the room temperature is not yet heated up Air conditioners operate more effectively if the temperature is to be maintained To drastically cool the air and inventory in a fully heated room requires much more time and en
16. ting units SCOPE OF DELIVERY 1 x unit 1 x bracket air hose 1 x operating instructions 1 x remote control 1 x sir outlet grid 1 x drainage hose 50 cm 1 x air hose 150 cm 1 x coarse filter top 1 coarse filter 2 x sealing plug 1 x air hose connector bottom BEFORE INITIATION 8 9 10 11 12 To avoid damage place the unit in an upright position for at least 24 hours before initiation Release the holder air hose in the unit and take out the extract air hose Fasten the air hose before initiating the unit Turn the extract air hose in the direction of the arrow 1 displayed and remove it from the unit Turn the extract air hose in the direction of the arrow 2 displayed and connect it to the unit Plug the power plug into a socket Never pull the plug out of the socket with force using the connection line This can damage the power cable Since the unit emits hot air please observe a sufficient minimum safety distance to each wall Fig 1 Despite the splash water protection you should not operate the unit in moist areas such as e g swimming baths or similar areas The colour of the unit can change slightly due to direct solar radiation The unit is equipped with a special thermal deactivation This protects the unit from overheating in extreme ambient conditions Please place the unit so that the air inlet is not impeded e g by furniture or curtains since this can negatively effect the capacity Do not e
17. winter in technical rooms like for example server rooms 11 CAUTION This unit may only be used by persons including children with reduced physical sensorial or mental capacity or with insufficient experience and lack of specialist know how if such persons are supervised by a person responsible for their safety or who has been trained in the use of the unit Children should be supervised to ensure they do not play with the unit POEM OPERATING PANEL 3 5 4 FUNC LU TEMP TEMP A 0 E d i Mu E g 3 o EN Ory y COOUNG DEHUMIDITr HEATING SLEEP oe Q Hi MID LOW AUTO Le SEPE TIMER 2 7 6 1 8 DESCRIPTION OF FUNCTIONS 1 POWER Press this switch to switch on or off 2 FUNC Press this switch to select between the functions Cooling Heating or Dehumidity 3 TEMP Press this switch in the cooling function in order to set the required room temperature by 1 C respectively up to a maximum temperature of 30 C Press this switch in the heating function in order to set the required room temperature by 1 C respectively up to a maximum temperature of 25 C 4 TEMP Press this switch in the cooling function in order to set the required room temperature by 1 C respectively up to a minimum temperature of 17 C Press this switch in the heating function in order to set the required room temperature by 1 C respect
18. xpose direct sunlight to shine on the unit since it may then overheat and automatically deactivate on account of the thermal deactivation NAME OF THE COMPONENTS 1 Operating panel 2 Control lamp 3 Air outlet grid 4 Air hose connection piece 5 Air hose 6 Upper condensation water outlet with rubber plug Sa 2222 2222 et zz 7 Cool inlet 8 Cool Air filter i 9 Hot inlet 10 Hot air filter 11 Drain pipe 11 IMPORTANT INSTRUCTIONS 1 Before initiation check if the operating voltage specified on the type plate complies with the local network voltage DO NOT BLOCK THE VENTILATION Make sure that the air outlet and air inlet are never blocked Only operate the unit on a horizontal surface to ensure no water leaks out The unit must not be operated in an area with explosive and caustic substances Clean the air filter regularly A contaminated air filter reduces capacity Please wait at least 5 minutes after switching off the unit before switching it back on to ensure the compressor is not damaged The compressor of the unit has a power demand of at least 7 amps Do not use any extension cable with this unit 8 The unit is designed for the cooling heating and dehumidification of inside rooms Other use is excluded 9 If the power cable is damaged it must be replaced by a qualified specialist for safety reasons 10 The unit is not intended for non stop cooling for proffessional use and for cooling in

Download Pdf Manuals

image

Related Search

Related Contents

Manual de usuario IS 400 COM  Mise en page 1  988726 - User Manual - H26 Floor Scrubber Rev STAR 0809.book  Monitor M31 Manual Instalação Rev D  Manual de Instrucciones  Swim'n Play 4ft User's Manual  Welch Allyn Spot Vital Signs LXi  Dacor EF36LNBSS User's Manual  TP-Link TL-POE200 User's Manual  Palson Melina  