Home

table of contents gb chap. 2 limitations chap. 1 general

image

Contents

1. damaged The intake grid is clogged The check valve is jammed The filter is dirty The intake grid is partly clogged The delivery piping is partly clogged The impeller is worn out Reverse rotation three phase models The filter is dirty Solids prevent the impeller rotating freely The temperature of the fluid is too high The motor is faulty Check the power supply and fit the plug well into the socket Rearm the switch If it trips again contact a qualified electrician Loosen up the impeller Contact the retailer Clean the grid Clean or replace the valve Clean the pump filter and or sponge kit Clean the grid Remove clogs Replace the impeller Check the direction of rotation and reverse if required Clean the pump filter and or sponge kit Remove obstructions Contact the retailer
2. every electropump is carefully tested and packaged Upon delivery check the electropump for damages if it has suffered damages during shipment immediately contact the retailer in any case no later than eight days from the date of purchase CHAP 2 LIMITATIONS The electropump is not suitable for pumping WARNING flammable or hazardous fluids Use of the electropump without fluids is strictly WARNING forbidden MAX TEMPERATURE OF PUMPED FLUID 0 0e eect 50 C max MAXIMMERSION DEPTH sisuiestieiucaven arretan 7 m with 10 m power supply cable MAX SIZE OF PUMPED SOLIDS irriaren 1 5 mm MAX NUMBER OF START UPS HOUR 30 equally shared Pumps with power supply cable measuring less than 10 m long must not be used outdoors CHAP 3 INSTALLATION DANGER All operations required for installing the pump must be A A Risk of carried out with the pump disconnected from the power electrocution supply system Screw the selected accessory to the outlet of the electropump Fit the filter sponge kit in the intake section if required Place the pump inside the tank it must be completely under water During handling do not use the power supply cable to lift the pump Fit the sprayer on the pump always above water level The pump can be secured to the resting table inside the tank using the anchor plate but because of the pump size this may be skipped Take care of leaving a gap around the pump so that the filtering section c
3. TABLE OF CONTENTS Chap 1 General Chap 5 Start up Chap 2 Limitations Chap 6 Maintenance Chap 3 Installation Chap 7 Troubleshooting Chap 4 Electrical connection Notice for the safety of people and things Pay special attention to the procedures marked by the following symbols DANGER It warns that failure to comply with the directions provided Risk of involves a risk of electrocution electrocution It warns that failure to comply with the directions provided N DANGER involves a very serious risk for people and or things It warns that failure to comply with the directions provided H WARNING involves the risk of damaging the electropump or equipment WARNING before installing the pump carefully read the content of this manual Damages due to failure to comply with its directions will not be covered by the warranty CHAP 1 GENERAL The VERSAILLES electropumps has been designed for use in fountains waterworks and waterfalls in water parks they are professional strong noiseless reliable and safe They are completely made of STAINLESS steel They are provided with a large intake filter that ensures a good operation of the pump for a long time As a standard they are provided with 230 V 50 Hz power supply ready to use since they already have an internal condenser and a power supply cable On request they can be supplied with 24V and 42 V low voltage alternated current without condensers and control panel At assembly
4. an be easily disassembled and removed The sponge kit is separately supplied it should be used only when the sprayers need a gap of less than 1 5 mm in diameter CHAP 4 ELECTRICAL CONNECTION Make sure the rated voltage and frequency match those H WARNING of the available power supply DANGER The installer will be responsible for checking that the Risk of power supply is provided with an efficient earthing aah system pursuant to the applicable regulations DANGER Check that the power supply is provided with a high AN Risk of sensitivity differential switch A 30 mA DIN VDE electrocution 01007739 Install the pump as directed and very carefully have it installed by skilled personnel if possible and keep children out of reach Do not connect the plug if the power supply cable or the pump are damaged Warning never put your hands in or get into the water without first disconnecting the pump and all the other powered accessories from the power supply before doing anything The pump can be operated on in tanks ponds or other indoors or outdoors provided no one is in contact with water Single phase model 230 V 50 Hz single phase models are equipped with a double earthing plug at the end of the power supply cable in this case the pump is earthed when the plug is fitted into the socket 24 or 42 V 50 Hz models do not have either condenser or plug in this case it will be the installer s responsibility to prepare the pow
5. er board and complete it with a condenser Three phase model In three phase models the earthing wire yellow green of the power supply cable must be connected to the earthing system of the power supply To connect the pump to the power supply use a magnetothermal omnipolar disconnecting switch which disconnects efficiently from the power system Overload protection The VERSAILLES single phase pumps features a thermal motor protector with an automatic resetting function so they do not need any external protection For protecting VERSAILLES three phase pumps use a magnetothermal motor protector or a contactor with a thermal relay both suitably gauged to the rated power Check of direction of rotation in three phase pumps If the pump rotates in reverse both its flow rate and head remarkably decrease The correct direction of rotation is clockwise looking at the pump from above When pressing the Start switch the pump will recoil in the opposite direction to its rotation the pump will be rotating in the correct direction therefore if it recoils anticlockwise Otherwise disconnect the pump from the power supply and invert two of its three phases CHAP 5 START UP See Fig 1 H WARNING Use the electropump within its rated performance range WARNING Do not operate the pump without fluids since this could damage its hydraulic components and seals Before starting a VERSAILLES electropump install the accessories plunge it
6. in water leaving the sprayer above water level CHAP 6 MAINTENANCE DANGER Before servicing the pump disconnect it from the Risk of power supply electrocution DANGER The powersupply cable must be replaced by the Risk of manufacturer or by the assistance service by means electrocution of special tools Under standard service conditions the VERSAILLES electropumps does not need any maintenance but for prevention and depending on its use occasional non stop or heavy duty Provide for planned inspections to have skilled personnel check at regular intervals the wearing of seals and the general state of the pump and power cable Check the filtering section at regular intervals to see if it is dirty do it more often if there are flowers or ornamental plants in the water or nearby To clean the intake section of the pump and the filters inside loosen the 3 wing nuts on the back of the pump remove dirt with a brush a jet of clean water or compressed air Do not use chemicals Occasionally clean the hydraulic components or replace the impeller as required CHAP 7 TROUBLESHOOTING THE ELECTROPUMP DOES NOT DELIVER THE MOTOR DOES NOT RUN THE PUMP DOES NOT DELIVER THE MOTOR RUNS THE PUMP DELIVERS A REDUCED FLOW RATE INTERMITTENT OPERATION SINGLE PHASE MODELS There is no power The plug has not been correctly itted in The differential switch has tripped The impeller is jammed The motor or condenser are