Home

700G/TRACK Data Logging Software

image

Contents

1. and Excel files e Clear logged data from the Gauge Minimum Requirements To use the Software Microsoft Windows 2000 SP4 XP SP2 Vista or Windows 7 is necessary To export data to Excel files Microsoft Excel version 2002 or newer is necessary How to Contact Fluke To contact Fluke call one of the following telephone numbers e Technical Support USA 1 800 44 FLUKE 1 800 443 5853 e Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 e Canada 1 800 36 FLUKE 1 800 363 5853 e Europe 31 402 675 200 e Japan 81 3 6714 3114 e Singapore 65 738 5655 e Anywhere in the world 1 425 446 5500 Or visit Fluke s website at www fluke com To register your product visit http register fluke com To view print or download the latest manual supplement visit http us fluke com usen support manuals 700G TRACK Users Manual Before You Start Before you start read this manual to learn more about the Software and its functions Standard Equipment Make sure your data logging kit comes with e 700G TRACK Software e USB Cable If something is missing contact Fluke See the How to Contact Fluke section Installation To install the Software 1 Put the Software CD into the CD drive on your computer 2 The install program starts automatically If it does not use Windows Explorer to find the CD drive and click on the setup exe program 3 Follow the directions on the screen to insta
2. Display Options Use the Display Options screen in the Options Menu to change the default selections for the run description fields When data is first uploaded the selections are set to the default values After the first data display the selections can be temporarily changed for the length of the data display In the Display Options screen check each field that is to be shown when the display mode is set to Selected Data Logged pressure Pressure Readings on the menu is always shown The Display Options Screen is shown in Figure 3 The Display Options are e Run or Label e Gauge Description e Log and Sample Type e Interval Time e Pressure Unit e Custom Factor 10 Trip Setpoint and Reset Initial Zero and Tare Zero Changes Temperature Readings Pressure Readings always selected Include 7 Run tt or Label Port lt Gauge Description Model lt Log and SampleT ype lt Records Used Interval Time lt Pressure Unit V Custom Factor 3 M Trip Setpoint and Reset Data Logging IV Initial Zero and Tare Interval V Zero Changes Log Type v Temperature Readings Log Temperature I Cancel Unit Trip Setpoint gto002 jpg Figure 3 The Display Options Screen Pressure Gauge Logging Pressure Export Options Use the Export Options screen to change the default selections for the file type and run description fields to be exported from the Log Up
3. ON and STOP if logging data Push to go to the next menu item Push to o Exit configuration if the display shows FULL ON or OFF o To stop logging and exit configuration if the display shows STOP o To start logging and exit configuration if the display shows START Display number of free log records Primary display number of free records Secondary display FREE A and V are ignored Push to go to the next menu item if not logging otherwise it exits configuration Push to exit configuration Select logging interval Primary display interval selection of 1 2 5 10 or 30 for seconds or 1 2 5 10 or 30 for minutes or 1 for hours Secondary display time unit SEC MIN or HOUR as applicable for the selection Push W to decrease the interval selection Stop at 1 second Push A to increase the interval selection Stop at 1 hour Push to go to the next menu item Push to exit configuration Select maximum number of samples Main display number of samples presently selected Secondary display SAMPL Push W to decrease the interval selection Stop at 1 Push A to increase the interval selection Stop at the maximum number of records 8500 Push to go to the next menu item Push to exit configuration Erase all logged data and set to Demand mode Primary display CLEAr Secondary display DATA 19 700G TRACK Users Manual e and Vare ignored e Push to go to the next menu
4. kpal Pressure in kilopascals Far Temperature in Fahrenheit Cel Temperature in Celsius 24 Error Codes The gauge uses the subsequent error codes 101 102 103 105 106 108 109 117 120 121 122 A non numeric entry was received where it should be a numeric entry Too many significant digits entered Invalid units or parameter value received Entry is above the upper limit of the allowable range Entry is below the lower limit of the allowable range A required command parameter was missing An invalid pressure unit was received An unknown command was received The serial input buffer overflowed Too many entries in the command line Pressure module not connected
5. 2Seconds Samples Run o Log Type Continuous Sample Type interval End y Log Temperature Yes y Unit PSI Custom Factor roo Trip Setpoint o Trip Reset pn gto001 jpg Figure 1 The Main Screen 700G TRACK Users Manual The lower section of the Main Screen shows controls you can use to configure data logging parameters in the Gauge send the configuration to the Gauge and retrieve the current configuration from the Gauge How to Connect to the Gauge To use the Software with the Gauge immediately 1 Double click the Software icon on the desktop to start the Software 2 Turn on the Gauge Connect the USB cable to the PC and to the Gauge 4 On the Software s Main Screen select the applicable COM Port from the Port dropdown Note COM Port detection is not automatic If necessary go to Windows Settings System Hardware Device Manager on your PC to determine the USB Serial Port 5 Push the Connect button The Main Screen populates with the settings from gauge See the Main Screen section for more information Note If the Gauge is off or if the USB cable is not connected you will receive an error message See Figure 2 File Gauge Options Help Port COMA v Connect Communications error obtaining the gauge identity Check the gauge power and connections then repeat the selection Log Temperature Unit Trip Setpoint LH Custom Factor
6. Trip Reset gto004 jpg Figure 2 Connection Error Alert How to Disconnect from the Gauge To disconnect from the Gauge click the Disconnect button The button description and function changes to Connect and all shown data is removed How to Upload Logged Data To upload logged data click the Upload button The logged data is uploaded and shown on the Log Upload Display A display shows percent complete and an estimate of the time remaining in the upload See the Log Upload Display section Pressure Gauge Logging Pressure How to Erase Logged Data To erase logged data click the Clear button After you give confirmation that logged data is to be erased all logged data is removed from the Gauge The data logging mode is set to Enabled Demand and all data on the display is refreshed How to Send Setup Configuration After you make the necessary selections click the Send button The configuration is sent to the Gauge and all data on the display is refreshed The data logging mode must be set to Enabled Download to change more than the mode How to Retrieve Setup Configuration To retrieve setup configuration data click the Retrieve button The gauge description current data capacity and setup are read from the Gauge and shown in the applicable fields Setup Configuration Fields The subsequent sections tell you how to set up the configuration fields Data Logging Mode Disabled This command turns off data log
7. WA 98206 9090 5602 BD Eindhoven U S A The Netherlands Table of Contents iS EEEE TET EE MINIMUM R q iremeNtS sriid siie otsan How to Contact Fl ke ncm e cet ce en e A ee ee ede Botore A a eE SAA AA EAA EMME EE E sedo tSc bes eo a oC Standard Equipment E p Instala rossi aiii OU iia a KAN SURIN eines ci Logging Pressure E di REA Aak Logging Pressure and Temperature MA TEE GAUGE MENU 23400 E E eam e Rt 700G TRACK Users Manual Help Men hm MEDION How to Connect to the Gauge isisisi eene enne How to Disconnect from the Gauge seen emen How to Upload Logged Data emm eee How to Erase Logged Data ient traer akan vana nne How to Send Setup Configuration sssseeeeen een How to Retrieve Setup Configuration eee Setup Configuration Flelds 22 teates noni otn tpi a tend pee in AA AAA Ataka nta Data LOGGING MOGe 5 ebrietate bet deti uhoaa ka usean aknea E sia koe A E T T T E A TIP SEPON mee E EN Nude MDA EU Log Upload DIS Play M dana tidad daria eye Export i E Excel Templates ctc EES Single Run Graph eere ttt HER e EEERPDR ERR p Ea A TRA EEEn quu steers Single Run Pressure and Temperature Graph Start Data Loggin
8. button to change the display options See the Display Options section The gauge has no real time clock The uploaded data is initially tagged by elapsed day and time from the start of a run The runs are identified by a numeric position in the uploaded data To record a label that gives more data about the run and to add a calendar date and time highlight the run and click the Set Date Label button The base date and time are added to the elapsed day and time for each sample To export one run highlight the run and click the Save Run button The Export Options screen is shown to let the options be customized for exporting this run A standard Save As screen is then shown Select the file name and the folder where the file is to be put Click the Cancel button of one of the screens to skip the export See the Export Options section for more To export all runs click the Save All button The Export Options screen is shown to let the options be customized for exporting these runs The same options are used for all runs For each run a Save As screen is then shown Select the file name and the folder where the file is to be 9 700G TRACK Users Manual put Click the Cancel button of the Save As screen to skip the export of that run Click the Cancel button of the Export Options screen to skip the export of all runs See the Export Options section The default location for files is the folder Fluke 700G Track in My Documents
9. configuration if the display shows STOP o Tostart logging and exit configuration if the display shows START Display number of free log records e Primary display number of free records e Secondary display FREE e and VP are ignored e Push to go to the next menu item if not logging otherwise it exits configuration e Push to exit configuration Erase all logged data and set to Demand mode e Primary display CLEAr e Secondary display DATA e Mand Vare ignored e Push to go to the next menu item and confirm erasure e Push to exit configuration without erasing the data Make sure that all logged data is erased and set to Demand mode e Primary display CLEAr e Secondary display CNFRM 17 700G TRACK Users Manual e and Vare ignored e Push to erase the data set Demand mode and exit configuration after the display briefly shows CLr to confirm erasure e Push to exit configuration without erasing the data When not logging data the Gauge works as given in the 700G Series Users Manual When a log run is started the pressure unit and custom factor are pushed to the downloaded selections They are changed to their initial values at the end of the run While logging data these changes occur e When 0 is pushed the log run to be stops before power is turned off e Power off on low battery detection stops the log run before power is turned off e Eis active and an event record including
10. data to make a complete spreadsheet presentation The templates can be used many times so it will not always be necessary to reformat some of your raw data The field options and Excel cell locations specified on the Export options screen must be synchronized with the predefined data in the template to make sure data is merged correctly Sample templates are supplied with the Software and are in their own folder on the CD The templates must be manually written to your hard drive The subsequent sections tell you more about them Pressure Gauge Excel Templates Single Run Graph The Single Run Graph template has custom titles and a graph of the merged data The vertical axis of the graph is scaled to the range of the uploaded pressure values and the horizontal axis is scaled to the number of samples uploaded The template file name is 700GTRACK template single run pressure graph xlt For the Export options for this template see Table 1 Table 1 Single Run Graph Template Export Options Include Insert Excel Field Description Cell IN and Sample B10 K RE SE MES E Setpoint and B16 Reset Initial Zero and E E 15 700G TRACK Users Manual Single Run Pressure and Temperature Graph The Single Run Pressure and Temperature Graph template has custom titles and a graph of the merged data The pressure graph vertical axis is scaled to the range of the uploaded pressure values The horizontal axis is scal
11. Lo 700G TRACK Data Logging Software Users Manual November 2011 2011 Fluke Corporation All rights reserved All product names are trademarks of their respective companies LIMITED WARRANTY AND LIMITATION OF LIABILITY BY USING THIS SOFTWARE PRODUCT IN ANY MANNER YOU ARE AGREEING TO ACCEPT THE FOLLOWING TERMS AND CONDITIONS Fluke Corporation Fluke grants you a non exclusive right to use the 700G TRACK Logging License Agreement Product and to make copies as necessary for you internal company use This grant of license does not include the right to copy modify rent lease sell transfer or distribute the Product or any portion thereof You may not reverse engineer decompile or disassemble the Product FLUKE DISCLAIMS ALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THE SOFTWARE AND THE ACCOMPANYING WRITTEN MATERIALS FLUKE ALSO DISCLAIMS THE WARRANTY OF NON INFRINGEMENT In no event shall Fluke be liable for any damages whatsoever including without limitation indirect consequential or incidental damages damages for loss of business profits business interruption loss of business information or other pecuniary loss arising out of the use of or inability to use this Product even if Fluke has been advised of the possibility of such damages Fluke Corporation Fluke Europe B V P O Box 9090 P O Box 1186 Everett
12. e e Average reading 13 700G TRACK Users Manual e Minimum reading e Maximum reading e Pressure unit The second third and further values are put into cells to the right of the first If the field description is included the field description is put into the specified cell column and the field values are put into the cell columns to the right If the field description is not included the field values are put in the specified cell columns Temperature Readings If temperature indications are in the uploaded data they are shown one for each row and start at the applicable cell row There are two field values for each value sample e Temperature e Temperature unit The second value is put in the cell to the right of the first There are four field values for each triple value sample e Average temperature e Temperature at the time of the minimum pressure e Temperature at the time of the maximum pressure e Temperature units 14 If the field description is included the field description is put in the specified cell column and the field values are put in the cell columns to the right If the field description is not included the field values are put in the specified cell columns Excel Templates An Excel template is made like a typical spreadsheet but the file is named with the xIt file extension The templates can have predefined text titles graphs and calculations which you can use with uploaded pressure
13. e of logging Trip high Interval samples are kept during the run only when the sample values are above a high limit Sample storage starts when a sample value of the interval becomes more than the trip setpoint and continues at each interval until a subsequent sample value of the interval is lower than the trip reset Sample storage then stops until a sample value again becomes more than the trip setpoint The sample value is recorded and specified by the sample type selection below Trip low Interval samples are only kept during the run when the sample values are above a low limit Sample storage starts when a sample value of an interval becomes less than the trip setpoint and continues at each interval until 8 a subsequent interval s sample value becomes larger than the trip reset Sample storage then stops until a sample value again becomes less than the trip setpoint The sample value is recorded and specified by the sample type selection below Trip span Interval samples are kept during the run only when the pressure difference during the interval is more than a maximum span or range Sample storage starts when the difference between a maximum and minimum measurement of an interval becomes larger than the trip setpoint and continues at each interval until a subsequent difference of the interval becomes less than the trip reset Sample storage then stops until a difference of the interval again becomes more than the tri
14. ed to the number of samples uploaded The temperature graph vertical axis is scaled to the range of the uploaded temperature values The horizontal axis is scaled to the number of samples uploaded The template file name is 700G TRACK template single run pressure temperature graph xlt For the Export options for this template see Table 2 16 Table 2 Single Run Pressure and Temperature Graph Options Include Insert Excel Field Description Cell Log and Sample B10 a sa Teate Custom Factor E KON A E Trip Setpoint and B16 Reset Initial Zero and TON E Pressure Gauge Start Data Logging on Gauge Start Data Logging on Gauge Set Download or Demand mode from the Software Download Mode Download Mode shows LOG in the primary display and DATA in the secondary display Push to go to the current configuration functions or push to go to the new data logging branch The data logging configuration menu sequence new branch is 1 Start or stop data logging Primary display LOG Secondary display FULL if the log memory is full OFF if not logging data or ON if logging data A and V are ignored if the log memory is FULL otherwise push either button to toggle between OFF and START if not logging data or to toggle between ON and STOP if logging data Push to go to the next menu item Push to o Exit configuration if the display shows FULL ON or OFF o To stop logging and exit
15. erature compensation on Returns state of temperature compensation Return 2410 ADC counts Turns off SI mode Turns on SI mode Stores calibration data Turns auto shutdown off Turns auto shutdown on Pressure Gauge Parameter Units CUST MULT STREAM OFF STREAM ON HC TEMP VAL HC CMD LIST TEMP UNIT TEMP UNIT Sets the multiplier for the custom unit type Turns off streaming data Turns on streaming data Same as TEMP Returns the measured pressure value in selected units Prints out a command list Used to set temperature unit Returns temperature unit Parameter Units The subsequent list of units is used with the Gauge Psi Bar mBar Kg cm2 InH204C InH2020C InH2060F mH204C MH2020C cmH204C cmH204C ftH204C ftH2020C Pressure in pounds per square inch Pressure in bars Pressure in millibars Pressure in kilograms per centimeter squared Pressure in inches of water at 4 C Pressure in inches of water at 20 C Pressure in inches of water at 60 F Pressure in meters of water at 4 C Pressure in meters of water at 20 C Pressure in centimeters of water at 4 C Pressure in centimeters of water at 20 C Pressure in feet of water at 4 C Pressure in feet of water at 20 C 23 700G TRACK Users Manual ftH2060F Pressure in feet of water at 60 F InhgOC Pressure in inches of mercury at 0 C mmhg0C Pressure in millimeters of mercury at 0 C
16. g on Gauge sssesssseeee eene enne eene nennen nennen Download Boro c Demand Mode sion eee Se al Interface Instructor cocer ay exe ovens thc xeu ruote doe c queo kaal aes Contents continued Initiating Communication List of COMMANAS ccccccccceceacessececececeaeeaseceeececeaueaeceeeeeseaueaseceeeeeseaueaseeeesenseanenes Parameter UNIS nm Lect Dre co rte esee ile ilogico Error COdSSismmmavaatasmiksia vaivu c A Fer Ya Dao E vo PE ERI Vue ERE SAN Een Wow ane ET eva S ver SMS iii 700G TRACK Users Manual List of Tables Table Title Page 1 Single Run Graph Template Export Options enennnnnaneeanenananenanneenenan naa 2 Single Run Pressure and Temperature Graph Options 700G TRACK Users Manual vi Figure Dow List of Figures Title Page The Main Screen RM Connection Error Alert nnne a a nnne terne nennen 6 The Display OptiONS Screen EMEA THE Export Options SCKEOM mer vii 700G TRACK Users Manual viii Introduction The Fluke 700G TRACK Software the Software extends the functions of the Fluke 700G Series Pressure Gauge the Gauge Use this manual with the 700G Series Users Manual The Software lets you e Setup data logging configuration in the Gauge e Upload logged data from the Gauge including export of run data to text comma separated values CSV
17. g parameters between runs and will not change logged data already in memory When the data logging mode is Demand mode you can set the Gauge to log data without a computer connection You can record and change some of the data logging parameters with the Gauge menus while the remaining parameters default to set values The gauge menus can be used to change the logging parameters between runs This will not change previously logged data 700G TRACK Users Manual Menus The Software menus duplicate the functions of the Gauge You can use the buttons or the Software menu to interface with the Gauge File Menu The File Menu lets you exit the Software Gauge Menu The Gauge Menu contains the functions that interact with the Gauge Connect Disconnect Upload Data Connect the Gauge and shows the Gauge description and data logging setup On the Primary Display select the communication port that the Gauge is connected to before you use this function See How to Connect to the Gauge in the Primary Display section Disconnect from the Gauge See How to Disconnect from the Gauge in the Main Screen section Upload all data logging runs from the Gauge and show them on the Log Upload Display See the Log Upload Display section The data can be exported from that display See the How to Upload Logged Data Clear Data Send Setup Retrieve Setup description in the Main Screen section Erase all data logging ru
18. ging in the Gauge All data logging functions are removed from the Gauge s CONFIG menu sequence Enabled Download Turns on data logging in the Gauge with all logging parameters downloaded from the Software All data logging functions related to parameter changes are removed from the Gauge s CONFIG menu sequence The only gauge functions available are start and stop of data logging show the number of free records and erase all logged data Enabled Demand Turns on data logging in the Gauge with all logging parameters set This can only be used to upload logged data erase all logged data get data logging parameters and change the data logging mode The data logging functions that are available in the Gauge s CONFIG menu sequence are start and stop data logging show the number of free records change the logging interval change the samples each run and erase all logged data The log type is set at Continuous and the sample type is set at Interval End Interval Use one of these sampling intervals e 1 2 5 10 or 30 seconds e 1 2 5 10 or 30 minutes e 1hour 700G TRACK Users Manual Samples Run The Samples Run field is the maximum number of samples to log each run This can range from 1 to 8500 Log Temperature Select Yes or No to log temperature Log Type Continuous A sample is kept at each interval of the run The sample value is specified by the sample type selection below This is the most common typ
19. item and confirm erasure e Push to exit configuration without erasing the data 6 Confirm erasure of all logged data and set to Demand mode e Main display CLEAr e Secondary display CNFRM e and V are ignored e Push to erase the data set Demand mode and exit configuration after briefly displaying CLr to confirm erasure e Push to exit configuration This will not erase the data While not logging data the Gauge works as given in the 700G Series Users Manual When a log run starts the pressure unit and custom factor are left at the values set by the current configuration functions While logging data these changes occur e Push to stop the log run before power is turned off 20 Power off on low battery detection stops the log run before power is turned off E is active and an event record including the change in the zero offset value is recorded in the log The Gauge s Auto off function is disabled It is change to its original value at the end of the run Engineering units damp sample rate tare and custom factor items on the existing configuration menu are disabled The units field on the display goes between the units the text LOG and the text RUN at a rate of one time each second This shows that data logging is on and the number after the text RUN identifies the run number Pressure Gauge Serial Interface Instructions Serial Interface Instructions The subsequent sections te
20. le cell and the field value is put into the subsequent cell to the right If the field description is not included the field value is put in the specified cell The Gauge Description has four values e Manufacturer e Model e Serial number e Firmware version These are in one cell isolated by commas The Log and Data Type Trip Setpoint and Reset and Initial Zero and Tare fields each have two data items that occupy two rows Each has its own description and field value with the second row below the first Zero Changes Zero changes are shown one for each row and start at the specified cell row There are four field values for each zero change e the date e thetime e the new zero setting e the pressure unit The second third and fourth values are put into the cells to the right of the first If the field description is included the field description is put into the applicable cell column and the field values are put into the cell columns to the right If the field description is not included the field values are put in the applicable cell columns Pressure Readings Pressure is shown one for each row and start at the specified cell row There are four field values for each value pressure indication e Date e Time e Reading e Pressure unit The second third and fourth values are placed in the cells next to the right of the first There are six field values for each triple value pressure reading e Date e Tim
21. le value case is 1697 sample sets Intervals The interval time setting sets the frequency of sample calculation and storage Eleven discrete interval times are available and range from 1 second to 1 hour A sample value is calculated at the end of each interval and comes from all of the pressure measurements made during that interval The sample value can be the last measurement made in the interval or it can be the average minimum maximum or median of all of the measurements made during that interval A sample value can be kept for each interval during the run only for those intervals where the sample value is larger than a specified high or low limit or only for those intervals where the pressure differential during the interval is larger than a maximum span Data Logging Modes Two data logging modes are available Download and Demand Multiple log runs can be used in these modes with the most number of runs dependent on the number of samples recorded in each run and the Gauge capacity Use Download mode to record or change the data logging parameters and send them to the Gauge The gauge stays in this mode until the application or the Gauge CLEAr DATA function is used to clear the recorded data in the Gauge At this point the mode is set to Demand In Download mode the parameters cannot be changed with the Gauge menus and the downloaded values are used for each new log run Download mode can be used to change the loggin
22. ll the Software Overview The gauge can record log multiple data sets each of which is identified by a sequential run number Data logging runs use new items put into the Gauge s CONFIG menu sequence to start and stop the runs Logging parameters can be changed for each data run The logging runs can be as short or long as necessary The length of the runs align with the storage capacity of the Gauge For each sample the Gauge can log pressure or it can log pressure and temperature This selection applies to all runs and must be made before you start the first run Logging Pressure When logging only pressure the Gauge has a capacity of 8500 data records These records keep run identification and log sample data Seven records are necessary for each new data logging run for run identification overhead One record is necessary to log each sample except for the triple value case average minimum maximum where three records log each sample set For a single run the capacity for all but the triple value case is 8493 sample sets and the capacity for the triple value case is 2831 sample sets Pressure Gauge Logging Pressure Logging Pressure and Temperature When pressure and temperature are logged the Gauge has a capacity of 5100 data records that keep run identification and log sample data For a single run the maximum capacity for all but the triple value case is 5093 samples and the maximum capacity for the trip
23. ll you how to set up the Gauge for serial communication Initiating Communication Terminal communication can be setup with terminal communication Software on a PC The terminal must be set as follows Bits per second 9600 Data bits 8 Parity None Stop bits 1 Flow control None Local echo on 21 700G TRACK Users Manual List of Commands Use the subsequent list of commands to communicate with the Gauge CAL START CLS FAULT IDN TARE TARE PRES UNIT PRES UNIT ZERO MEAS ZERO MEAS 22 Puts the calibrator in calibration mode Clears the error gueue Returns an error code from the error gueue Identification query Returns the manufacturer model number and firmware revision level of the Calibrator Tares the offset pressure of the reading on the calibrator Returns the current tare value Returns the pressure unit for the upper display Sets the pressure unit for the display Zeros pressure of the calibrator Returns the current zero offset value MINMAX RST MIN MAX HC OFF HC DFLT TEMP HC COMP OFF HC COMP ON HC COMP HC RD 2410 HC SI OFF HC SI ON CAL STORE HC AUTO OFF HC AUTO ON Resets the minimum and maximum recorded values Returns the minimum recorded value Returns the maximum recorded value Turns off unit Sets auto off defaults Returns temperature in the chosen units Turns off temperature compensation Turns on temp
24. load Display When data is first uploaded the selections are set to these default values After the first data display the selections can be temporarily changed for each export and stay changed for the length of the data display Logged pressure is always exported See Figure 4 File Type NS Multiple runs in Single file Excel Template Include Field Insert Description Excel Cell M Run or Label iv a M Gauge Description Log and Sample Type lt a Interval Time lt a Pressure Unit s Custom Factor a ie to Trip Setpoint and Reset lt a IV Initial Zero and Tare IV Zero Changes lt M Temperature Readings rm lt Cancel Figure 4 The Export Options Screen gto003 jpg 11 700G TRACK Users Manual The selections are as follows File Type TXT File You can print a formatted text file or open it in a text editor The run description fields are put on isolated lines at the start of the file followed by a line for each logged data sample and zero change CSV File An Excel Comma Separated Variable file has each item on a line in quotation marks and all items are separated by commas The run description fields are put on isolated lines at the start of the file followed by a line for each logged data sample and zero change New Excel File A new Excel spreadsheet xls file The locations of the run description fields logged data samples and zero cha
25. nges in the spreadsheet are shown in the Excel Cell column below See the Minimum Requirements section Excel Template An Excel spreadsheet xls file that comes from a predefined Excel template xlt file The locations of the run description fields logged data samples and zero changes in the spreadsheet are put into Excel Cell columns These locations must be synchronized with the set data in the template See the Minimum Requirements section See the Excel Templates section 12 Multiple runs in Single File When the upload has many runs export all runs to one file Separate Files When the upload contains many runs export each run to an isolated file Excel Template When the file type is set to Excel Template the template you will use is selected here Click on the Browse button and go to the necessary template file See the Excel Templates section Include Field Put a mark by each field to be exported Logged pressure data is always exported Insert Description An optional field description can be included for each field you will export Put a mark on each field description to be included Pressure Gauge Logging Pressure Excel Cell Record the cell location where you put the data Cell columns can range from A to YZ Cell rows can range from 1 to 99999 The data fields are put as follows Run Description Fields If the field description is included the field description is put into the applicab
26. ns from the Gauge See How to Clear Logged Data in the Main Screen section Send the setup data to the Gauge See the How to Send Setup Configuration description in the Main Screen section Get the setup data from the Gauge See the How to Retrieve Setup Configuration description in the Main Screen section Pressure Gauge Logging Pressure Options Menu The Options Menu specifies the default display and export options See the Display Options and Export Options sections Help Menu The functions necessary for help and support are in the Help Menu Help Shows online help Support Shows customer support data Registration Tells you how to register the Software About Shows Software description and version data Main Screen The Main Screen is shown in Figure 1 The Main Screen controls let you Connect to the Gauge Disconnect from the Gauge Upload logged data Clear logged data Exit the application This data is shown on the main screen when you connect the Gauge e Gauge model e Serial number e Firmware version of the Gauge e Number of data logging records used e Number of data logging records free 700G TRACK File Gauge Options Help Port COMA Disconnect Upload Clear Exit Model MAKE MODEL Serial 0000000000 Version 3 00 Records Used 0 Records Free 5100 SETUP Send Retrieve Data Logging Enabled Demand Available recording time 2 43 46 Interval
27. p setpoint Sample Type The Sample Type field is recorded as one of these fields e Interval end The last measurement made in the sample interval e Average of all measurements made in the sample interval e Minimum of all measurements made in the sample interval e Maximum of all measurements made in the sample interval Pressure Gauge Logging Pressure e Median of all measurements made in the sample interval the midpoint between minimum and maximum e Average minimum and maximum of all measurements made in the sample interval Three records of storage for each logged sample set are necessary This decreases capacity by 3 Unit Pressure units known by the current gauge configuration Custom units are included Custom Factor Custom unit conversion factor shown as units for psi Trip Setpoint Trip setpoint as specified for the Log Type selected above shown in the log unit selected above Trip Reset Trip reset as specified for the Log Type selected shown in the log unit selected Log Upload Display Push the upload button to upload data files from the Gauge The Primary display shows each data logging run found in the uploaded data To show a run s data in the lower section of the display click on it to highlight it Use the Display Mode box to select the subset of run data shown e All Data e Selected Data e Readings Only When the Display Mode is set to Selected Data click the Change Selection
28. the change in the zero offset value is placed into the log e The gauge s Auto Off feature is disabled It is changed to its initial value at the end of the run e Engineering units damp sample rate tare and custom factor functions on the current configuration menu are disabled 18 e The units field on the display cycles between the units the text LOG and the text RUN at a rate of one time each second This shows that data logging is on and the number after the text RUN shows the run number Demand Mode You can make a data measurement log without a computer In Demand mode a computer is not necessary to configure all of the logging parameters When data logging is active a new item is added at the start of the configuration menu tree to point you to a different branch which contains all data logging functions This new menu item shows LOG in the primary display and DATA in the secondary display Push to go to the current configuration functions or push to go to the new data logging branch The data logging configuration menu sequence new branch is as follows 1 Start or stop data logging e Primary display LOG e Secondary display FULL if the log memory is full OFF if not logging data or ON if logging data e and Vare ignored if the log memory is FULL otherwise push either button to go between OFF Pressure Gauge Start Data Logging on Gauge and START if not logging data or to go between

Download Pdf Manuals

image

Related Search

Related Contents

Kenmore 18'' Oscillating Stand Fan w/ Remote Owner's Manual  MTD Series 400 Lawn Mower User Manual  PDFダウンロード - 日本電気  LG WT5480CW Specification Sheet  Hans Grohe 10028XX1 User's Manual  MANUALE ISTRUZIONI  INALCO Département d`Études russes 2014-2015  Samsung GT-C3332 User Manual  取扱説明書 葉智語一  User Manual Connection to 3S symbolic  