Home
USB Mercury T2C Quick Start
Contents
1. EO TELEDYNE LECROY Everywhereyoulook USB Mercury T2C Quick Start l Introduction The Teledyne LeCroy USB Mercury T2C USB 2 0 Protocol Analyzer is a verification system for USB development and testing It supports USB 2 0 and the Power Delivery Protocol that runs over the Type C TM connector It is designed to record USB traffic and graphically present the logical transactions and events It connects to a laptop or desktop PC via USB 2 0 The Mercury T2C is powered by the USB cable so no additional power cord is needed _ Mercury 72C USB 2 0 Power Delivery Coes O O0 Status Trig Rec Please see the Readme file on the installation DVD for the latest information on PC requirements and supported operating systems The system can monitor USB 2 0 traffic Hi Speed Full Speed and Low Speed using compliant USB 2 0 cables as well as Power Delivery 2 0 traffic over the USB Type C to Type C cables It will work with all existing USB 2 0 devices and hosts using the supplied Adapters as well as new ones incorporating the Type C connectors The total length of the cables between the Host under test and the Device under test should be kept to lt 4 feet 2 Components The Teledyne LeCroy Mercury T2C Analyzer package includes the following items e One Teledyne LeCroy USB Mercury T2C Analyzer Five USB cables A to C C to C C to B C to uB C to A Receptacle e Installation DVD ROM including document
2. ation e Quick Start Guide Please see the USB Protocol Suite User Manual on the installation DVD for component specifications 3 Description Mercury T2c USB 2 0 Power Delivery Qoc o 0 0 oc Pwr Status Trig Rec The front panel has the following indicators and connectors Connector 1 LED Green Good Red Flip it over Analyzer Connector 1 downstream Connects to Device under test UFP Power LED Green if on Status LED Blue if system successfully initializes Red while booting If red for more than a minute hardware failure Green while initializing Analyzer LEDs Trig Trigger Green if triggering Rec Recording Red if recording enabled Analyzer Connector 2 upstream Connects to Host under test DFP Connector 2 LED Green Good Red Flip it over Aux eo teledynelecroy com e USB 2 0 PD Protocol Analyzer e Mercury T2C e 925432 00 The rear panel has the following indicators and connectors Aux 9 pin Mini DIN connector used for External Trigger In and Out BNC connections Cable sold separately ACO32XXA X USB Type C connector for connection to host computer running USB Protocol Suite Warning Do not open the enclosure No operator serviceable parts are inside Refer servicing to Teledyne LeCroy customer care 4 Installing the Software Note You must install the software before connecting the Analyzer to the host machine for the first time Refer to the S
3. e the recording options you selected 5 Turn on the USB devices under test and initiate data transfer or otherwise create traffic on the link 6 Click Record on the Tool Bar The system starts to record the USB traffic immediately After 16 MB of traffic are recorded the Analyzer uploads the data and displays the packets in the trace window 7 To terminate recording before the snapshot automatically completes click m lon the Tool Bar When the recording session is finished the traffic is automatically uploaded from the Analyzer to the hard drive on your PC as a file named data usb or the name you assigned as the default filename While the file is being uploaded you should see a brown progress bar at the bottom of the screen When the bar disappears it indicates that the data has been uploaded to disk 8 To save a current recording for future reference select Save As under File on the Menu Bar OR click on the Tool Bar to display the standard Save As screen Give the recording a unique name and save it to the appropriate directory For additional information on the results display see the USB Protocol Suite User Manual Teledyne LeCroy Customer Support Mail 3385 Scott Blvd Santa Clara CA 95054 3115 Web _ teledynelecroy com tm Library software PSG E mail psgsupport teledynelecroy com Tel 800 909 7112 USA and Canada Tel 408 653 1260 worldwide Fax 408 727 6622 worldwide Trademarks and Service
4. lled in your PC 6 Starting the Application To start the application launch the Teledyne LeCroy USB Protocol Suite program from the Start Menu Start gt Programs gt LeCroy gt USB Protocol Suite gt USB Protocol Suite You can use the software with or without the system connected to the host Without the Analyzer the program functions as a trace viewer to view analyze and print trace files The first time you open the USB Protocol Suite application confirm proper installation by selecting About from the Help menu to view the Software Version Firmware Version BusEngine Version and Unit Serial Number Note When the Mercury T2C is unplugged from the host it loses its Bus Engine image The image updates automatically when the Application runs r First USB Recording After installing and launching the software you can test the system by performing the following steps 1 Connect cables to the Device and Host under test UFP and DFP Connect the Device to Connector 1 and the Host to Connector 2 If the connector LED s show Red flip them over This will allow any high speed data on the 3 1 twisted pairs to be connected together if they exist 2 Select Recording Options under Setup on the Menu Bar 3 Select the General tab to display the following dialog box showing factory default settings such as Snapshot and 16 MB buffer size For the first recording you can leave these settings unchanged 4 Click OK to activat
5. marks Teledyne LeCroy Teledyne LeCroy Mercury T2C USB Protocol Suite CATC Trace and BusEngine are trademarks of Teledyne LeCroy Microsoft and Windows are registered trademarks of Microsoft Inc All other trademarks are property of their respective companies Disclaimer Users are fully responsible for their application of any products The Software License and Limited Warranty for the accompanying product are set forth in information that shipped with the product and are incorporated herein by this reference If you are unable to locate the Software License or Limited Warranty contact Teledyne LeCroy for a copy Changes Product specifications are subject to change without notice Teledyne LeCroy reserves the right to revise the information in this document without notice or penalty Copyright 2015 Teledyne LeCroy Inc All rights reserved Part Number 925222 00 Rev A April 2015 This document may be printed and reproduced without additional permission but all copies should contain this copyright notice
6. ystem Requirements in the readme file for information about the exact Windows operating systems supported 1 Insert the installation disc into the host machine s DVD drive Typically the installation process will automatically start If it doesn t browse to the Autorun folder on the installation disc then double click the autorun exe file 3 Follow the on screen instructions to complete the installation Note If you get an error message during installation of the drivers consult your system administrator 5 Setting Up the Analyzer To set up the Analyzer 1 Connect the USB port to a USB port on the PC using the LONG 3 foot 1 meter USB 2 0 cable Note Use of a longer cable for this connection may cause the Mercury T2C to malfunction 2 Plug the Analyzer Host s USB cable into the USB Type C Connector in the rear of the Mercury T2C At power on the Analyzer initializes itself in approximately ten seconds and performs an exhaustive self diagnostic that lasts about five seconds 3 Click Next after you see the Add New Hardware Wizard window 4 Follow the Microsoft Windows on screen Plug and Play instructions for the automatic installation of the Analyzer as a USB device on your analyzing PC the required USB files are included on the Installation DVD 5 Click Finish when you see the message that says Windows has finished installing the software that your new hardware requires and the driver files have been insta
Download Pdf Manuals
Related Search
Related Contents
Olympus C-300 ZOOM Digital Camera User Manual incubation des oeufs Genius ECO u500 取扱説明書 [PDF形式] AUTOMATIC TRANSMISSION StarTech.com 1 ft High Speed HDMI® Cable with Ethernet - HDMI to HDMI Mini- M/M Harbor Freight Tools 44849 User's Manual 薬食安発第 ーー09002号 Samsung XE300TZCI User Manual (Windows 8) Copyright © All rights reserved.