Home

A602 – 6U VME64 PowerPC® Safe Computer

image

Contents

1. by any such person in reliance whether wholly or partially on the whole or any part of the contents of the publication The correct function of MEN products in mission critical and life critical applications is limited to the environmental specification given for each product in the technical user manual The correct function of MEN products under extended environmental conditions is limited to the individual requirement specification and subsequent validation documents for each product for the applicable use case and has to be agreed upon in writing by MEN and the customer Should the customer purchase or use MEN products for any unintended or unauthorized application the customer shall indemnify and hold MEN and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages and expenses and reasonable attorney fees arising out of directly or indirectly any claim or personal injury or death associated with such unintended or unauthorized use even if such claim alleges that MEN was negligent regarding the design or manufacture of the part In no case is MEN liable for the correct function of the technical installation where MEN products are a part of Copyright 2015 MEN Mikro Elektronik GmbH All rights reserved A602 Data Sheet 2013 08 23 Page 8
2. 5V 3 5 o 3 3V 5 5 optional o Standard backplane supplies both input rails with power o Continued operation if one power input fails or is not present o Separate power supplies for the three CPUs and the three main memory ranks Supply voltage power consumption o 33W 39W when 3 3V are not supplied o 6 W optional 3 3V supply Dimensions standard double Eurocard 233 3mm x 160mm Weight without mezzanines and accessories 548g Temperature range operation o 1 slot models 40 55 C qualified components temperature classes T1 T2 and TX inside buildings or in containers with temperature control for signalling equipment according to EN 50125 3 table 2 o 2 slot models 40 70 C qualified components temperature classes T1 T2 and T3 for equipment onboard rolling stock according to EN 50125 1 table 2 o Airflow min 2 m s Temperature range storage 40 85 C Relative humidity operation max 95 non condensing Relative humidity storage max 95 non condensing Altitude 300m to 2 000m EN50124 Class AX Compliant to EN50125 1 meeting requirements of EN61373 Cat 1 Class B and Classes GTX GL3 for rolling stock a Shock 50 m s2 30 ms EN 61373 a Vibration function 1 m s2 5 Hz 150 Hz EN 61373 a Vibration lifetime 7 9 m s2 5 Hz 150 Hz EN 61373 For signalling equipment a distance of 3m from the track bed is required Protection class IPOO EN50124 Category PD1 Co
3. A602 6U VME64 PowerPC Safe Computer 3x PowerPC 750 lockstep mode 3x 512 MB DDR RAM Fail operational fault tolerant behavior Fail safe and fail silent board architecture Clustering of two A602 to raise availability Board management BITE SEU radiation tolerant Certifiable up to SIL 4 with report from TUV Siid and DAL A Developed according to RTCA DO 254 EN 50129 and IEC 61508 E EN 50155 compliance E Up to 40 to 70 C with qualified components E Convection or conduction cooling The A602 is a 6U 64 bit VME COTS computer with onboard functional safety that realizes triple redundancy on a single board to achieve fail operational fault tolerant behavior The board can also act as a fail silent subsystem i e it can shut down in case of a fatal fault Its complex FPGA based design helps dramatically lower software development costs as it automatically manages the system s triple redundant processors and memory The result The system s redundant architecture is fully taken advantage of by software designed for a standard single CPU board The A602 is designed for deterministic operation and offers extensive BITE features e g ECC error counters for all types of memory monitoring of all internal voltages internal buses with error correction and fault tolerant fail operational implementation Its three processors run in lockstep mode with 2 out of 3 2003 voting implemented in FPGA and software assisted resynchroni
4. T o Also available at front panel a Data rates up to 460 800 Baud o 2x 256 Byte transmit receive buffer o Handshake lines none 12C bus Two PMC slots o 32 bit 33 MHz 3 3V V I O o PMC slot 1 with rear I O Voltage monitoring Temperature monitoring Watchdog Reset signal control Control of redundant power supplies Sleep mode o Lowers power consumption in case of primary power supply interruption o Power failure indicated through signals from backplane o Supports power interruptions specified in Airbus directive ABDO100 1 9 o CPUs and memory can be put into sleep mode Redundant clock generation Connection with second A602 possible with special backplane o Control of shared outputs o Exchange of state information o BMC and 6x UART link Page 3 Technical Data Local PCI Bus VMEbus Electrical Specifications Mechanical Specifications Environmental Specifications MTBF Safety A602 Data Sheet 2013 08 23 32 bit 33 MHz 3 3V V I O Compliant with PCI Specification 2 2 TS1148 controller Compliant with VME64 VME64 and 2eSST specification Slot 1 function with auto detection Master o DO8 EO D16 D32 D64 A16 A24 A32 ADO BLT RMW 1MB shared fast SRAM Mailbox functionality Single level 3 fair requester Single level 3 arbiter Bus timer Location Monitor Performance o Coupled read write D32 non block transfer rate 6 5 MB s Dual power input from VMEbus uninterrupted EN50155 Class 1 a
5. alified components 08CT15 00 Rear I O adapter for A602 without front panel with RS232 PMC rear I O 6x DEX UART BMCX AFDX debug signals 40 85 C with qualified components Software VxWorks This product is designed to work under VxWorks For details regarding supported unsupported board functions please refer to the corresponding software data sheets 10D602 60 VxWorks BSP MEN for A602 and D602 Software PikeOS This product is designed to work under PikeOS by SYSGO PikeOS is a real time operating system for use in safety and mission critical systems which can be certified according to DO 178B DAL B and EN 50128 SIL 4 For more information and product support please contact www sysgo com Software Firmware BIOS MENMON is MEN s firmware BIOS for PowerPC platforms 14A602 00 MENMON Firmware for A602 object code For operating systems not mentioned here contact MEN sales A602 Data Sheet 2013 08 23 Page 7 Ordering Information Documentation Compare Chart 6U VMEbus CPU and I O cards Download Compare Chart safe computers from MEN Download 23X602 00 SIL 4 railway certification package according to EN 5012x for A602 D602 including Safety User Manual including the safety relevant application requirements a detailed description of the hardware and instructions for appropriate operation Safety Case describing the concepts for reaching functional safety as well as all safety and quality relevant processes and meas
6. nformal coating on request All components soldered 270 311 h 40 C according to IEC TR 62380 RDF 2000 424 061 h for continuous operation 25 C according to IEC TR 62380 RDF 2000 Erroneous behavior of CPU memory subsystem lt 1E 8 h o Considering hardware failures and worst case SEU environment PCB manufactured with a flammability rating of 94V 0 by UL recognized manufacturers Page 4 Technical Data EMC Conformity BIOS Software Support A602 Data Sheet 2013 08 23 EN55011 radiated emission disturbances rolling stock EN 61000 6 4 radiated emission disturbances signalling equipment EN 61000 4 3 electromagnetic field immunity EN61000 4 2 electrostatic discharge immunity EN61000 4 8 power frequency magnetic field EN61000 4 9 pulsed magnetic field MENMON m VxWorks VxWorks Cert mu PikeOS Page 5 Configuration amp Options Standard Configurations Article No CPU Type Clock System RAM Flash FRAM PMC Slots Cooling Operating Temperature 01A602 02 3x PPC 750 1 GHz 3x 512 MB 2x 256 MB 1 MB 2 Convection 40 50 C CL Options Mezzanine Slots PMC slot 2 customized for AFDX PMC rear I O only Real time Clock Buffered by GoldCap Environmental Specifications Temperature range operation o 40 70 C 8HP front panel with convection cooling or 4HP front panel with conduction cooling Please note that some of these options may only be available for large volumes Please ask o
7. pota ae Rear I O only for AFDX E VME P2 VME P1 VME PO Memory Controller poses A602 Data Sheet 2013 08 23 Page 2 Technical Data CPU Memory 1 0 Mezzanine Slots Miscellaneous A602 Data Sheet 2013 08 23 3x PowerPC 750 CL o Scalable performance o 1 GHz processor core frequency o Superscalar o Classic PowerPC FPU MMU o CPU bus to FPGA 100 MHz 64 bit Lock step operation o All CPUs do the same thing at the same time o 2 out of 3 voting in FPGA with CPU bus clock speed 100MHz o Software assisted resynchronization o No functional interruption in case of an SEU inside the CPU Chipset o North and Southbridge realized in FPGA 2x 32 kB L1 cache 1MB L2 cache integrated in each CPU 3 independent ranks of 512MB DDR SDRAM system memory FPGA controlled o 100MHz memory bus frequency 32 bit Up to 800 MB s 2 out of 3 voting in FPGA Scrubbing to prevent accumulation of SEU No functional interruption in case of an SEU inside the memory 2 independent ranks of 256MB Flash FPGA controlled o Primary and backup Flash ranks contain the same data auto selection by boot loader o ECC protection 1MB FRAM a ECC protection AKB serial EEPROM for production data serial number etc o o og All I O realized in FPGA and available at rear I O Sextuple UART a E g for communication with other A602 o Data rates up to 460 800 Baud for each channel o Handshake lines none RS232 UAR
8. ur sales staff for more information A602 Data Sheet 2013 08 23 Page 6 Ordering Information Standard A602 Models 01A602 02 3x PowerPC 750CL 1 GHz 3x 512 MB DRAM 2x 256 MB Flash 1 MB FRAM 2 standard PMC slots convection cooling airflow 2 m s 40 to 50 C with qualified components Related Hardware 08CT15 00 Rear I O adapter for A602 without front panel with RS232 PMC rear I O 6x DEX UART BMCX AFDX debug signals 40 85 C with qualified components Certification Packages 23X602 00 SIL 4 railway certification package according to EN 5012x for A602 D602 including Safety User Manual including the safety relevant application requirements a detailed description of the hardware and instructions for appropriate operation Safety Case describing the concepts for reaching functional safety as well as all safety and quality relevant processes and measures to meet the SIL 4 requirements Assessment report and SIL 4 certificate from TUV SUD German Technical Inspection Agency Please contact us to get more information about the certification package and to request a copy of the documents For more information on the A602 D602 certification package see this introductory overview presentation PDF Miscellaneous Accessories 05P000 01 25 mounting screw sets to fix PMC XMC modules on carrier boards O8AE33 00 A602 D602 debug adapter to connect debug terminal JTAG equipment and Freescale CodeTest Probe 40 85 C with qu
9. ures to meet the SIL 4 requirements Assessment report and SIL 4 certificate from TUV SUD German Technical Inspection Agency Please contact us to get more information about the certification package and to request a copy of the documents For more information on the A602 D602 certification package see this introductory overview presentation PDF Contact Information Germany France USA MEN Mikro Elektronik GmbH MEN Mikro Elektronik SAS MEN Micro Inc Neuwieder Stra e 3 7 18 rue Ren Cassin 860 Penllyn Blue Bell Pike 90411 Nuremberg ZA de la Chatelaine Blue Bell PA 19422 Phone 49 911 99 33 5 0 74240 Gaillard Phone 215 542 9575 Fax 49 911 99 33 5 901 Phone 33 0 450 955 312 Fax 215 542 9577 Fax 33 0 450 955 211 info men de info men france fr sales menmicro com www men de www men france fr www menmicro com The date of issue stated in this data sheet refers to the Technical Data only Changes in ordering information given herein do not affect the date of issue All brand or product names are trademarks or registered trademarks of their respective holders MEN is not responsible for the results of any actions taken on the basis of information in the publication nor for any error in or omission from the publication MEN expressly disclaims all and any liability and responsibility to any person whether a reader of the publication or not in respect of anything and of the consequences of anything done or omitted to be done
10. zation while its triple redundant dynamic memory automatically corrects upsets caused by A602 Data Sheet 2013 08 23 cosmic radiation SEU and hardware faults The system is powered by redundant local power supplies with separate power supplies for the three CPUs and the three main memory ranks The A602 has been developed according to DO 254 compliant to DO 160 and certifiable up to DAL A in avionics applications Additionally the product meets the requirements of EN50128 EN50129 and can be deployed in signalling and rolling stock applications up to SIL 4 All I O is realized in SEU resistant FPGAs and available on the system s rear connectors Additionally the A602 offers two PMC slots with rear I O for PMC1 As an option the second PMC slot can be customized for an AFDX PMC rear I O only A second A602 can be connected to build a high reliability availability cluster The two A602s exchange data via a sextuple UART connection and a BMCX link men Page 1 Diagram Rear I O VME Px connector CPU 1 CPU 2 CPU 3 PowerPC PowerPC PowerPC D Front connector 750 750 750 Options CPU Voter RAM 1 512 MB Board N Management DDR RAM 2 Controller 512 MB FPGA RAM 3 512 MB Flash 1 256 MB ECC Memory Controller Flash 2 256 MB ECC M ae emory INB UART Controller 6x on ee Pine re Master ECC arc j o RS232 i PCI to VME i ts Foot H t lt Fy D Driver Seo bridge PMC1 OA EEP ROM i

Download Pdf Manuals

image

Related Search

Related Contents

Bissell BG9100NM Use and Care Manual  LaCie 12big User's Manual  Horizon Fuel Cell Software Adaptor User Manual  Produits Elucigene® Male Factor Infertility Mode d`emploi  Charte de Projet T.E.R.  Fiche produit  SBS TESPORTSPEAKER  「薄型の住宅用火災警報器」を4月1日から発売します。 (PDF:829KB)  American Standard Towel Ring 7005.190 User's Manual  PDFファイル・41.01MB  