Home

Infinity 2020 Perimeter Intrusion Detection System

image

Contents

1. a E Infinity 2020 Perimeter Intrusion Detection System User Guide Network Application t Line of Defense Infinity 2020 Perimeter Intrusion Detection System Table of Contents Section L Getting Started Eee ee eee eee en eee eee eee eee ee ee eee een 2 Network Application Browser Basel semiisinsiorunin ni unn nann N utes wate ident geass ees 2 Laneno ne APCO ea N A AE OAA A E A OA O AEA eee 3 Koy ULF NU Sesser ee ree eee eee epee E ee eee eee eee 4 Welk YS EI EA saeco E A A E A vac ccou or aee cach A E A EE E soeateen AA AE AE AT 5 debar Menu eee E EEA 6 WeaNer o uS UGIN Am anne a EAE EEEE AE A EE AE EA EEEE AE A AE E ee ee 8 Alarm NC cs neces et casemate vce cg cect eee we ca ce aes ease cas aaa aang ease coe eauie EESE SESE asec eeens ens ensenen 8 ZONE S 0 S ere oe eee Terre eT E rere ere eT Teer ere rere eee rere ere ere ee rere re eee 8 TAa olga A 0 E Cette Cr reer ener are tnt Sete eee ee ee ner Ree Ter ee eet ee ee ES ee ete eer eee 8 Section 2 Site Alarm Reporting and User Interaction cccesssssssessssssssssssssessssesessesssssssesssesessessssessssessssesessecnssesessesussesessesnsseeessecesseseeseaeeneenees 9 AE EV SUA TS asa a hse cabo accent te cai ch cae a es teeta ees ee eee 9 INS PVN Sesh sate Cate Seat E scence seen ce senses ge sees castes NSE 10 POC SSS ON Ful NG easter seater R A E E AE AA AE A EAA sates REAA RE EE E O de tote EE E AEAEE 11 Acknowledging and Clearing AVI NNS ssc ccsccecectetascssssdercseesdet
2. Active yes Ono Region Main Ea Status Secure Alarm Type Alarm Conditional on Zone Triggering on Zone Period 10 f E Vibration Monl a 190 s E Precipitation 20 Beet PE Audio Zone Alarm O Restore Defaults Copy Sensitivity Data Infinity 2020 Perimeter Intrusion Detection System Confirmation of the update is presented to the user with the response of Zone Record Saved Zone Setup x Zone Record Saved Controller i Controller Transponder 1 Transponder i Input 1 Zonel Zone Label Zone 1 Active yes O No Region Main Lanean Status Secure Alarm Type Alarm Conditional on Zone Select Triggering on Zone Se Period Vibration Wind Precipitation 20 a Audio Zone Alarm Restore Defaults Copy Sensitivity Data When the same Vibration Wind and Precipitation sensitivity changes are required across multiple zones the Copy Sensitivity Data can be quite helpful Zone Setup x Vibration 190 30 Precip 20 Copy Sensitivity Data to GSH zone 1 l Zone 2 Zone 3 Zone 4 l Zone 5 Zone 6 Zone7 C Zone 8 Update Zone Parameters Select the zones which the new sensitivities will be applied then execute by selecting Update Zone Parameters Note that Select All and Clear All are available for batch processing r Infinity 2020 Perimeter Intrusion Detection System To view or edit zone setup parameters via the Sidebar Me
3. Once the assignable cause has been determined the user simply selects it from the pull down and selects Clear Processor Status La Successfully acknowledged the alarm Controller Transponder 1 Transponder Communication Notice Clear ci a The clearing of processor type alarms takes longer than zone alarms especially on larger systems This is due to the fact that approximately 144 parameters per card are queried and verified against the application settings to ensure parameter integrity Alarm Queue X Clearing Controller Transponder 1 Transponder Communication Notice Clear Testing v Finally the Clearing is confirmed Alarm Queue Successfully Cleared Alarm Infinity 2020 Perimeter Intrusion Detection System Managing Assignable Causes Various customers and sites may need to add assignable causes to meet their particular needs This requires an administrator type role to be logged in Selecting the Manage Causes item in the sidebar reveals the Search Assignable Cause page Manage Causes search Assignable Cause Add New AssignableCause Selecting Search provides the current active listing of assignable causes and their listing order Manage Causes search Assignable Cause Add New AssigqnableCause Edit Fence Cut Edit Testing Edit Weather Edit True Alarm Edit Gate Open Edit Animal Description Tumbleweed Status Active Note that the user can inac
4. Alarms Period 6 21 2010 pr Infinity 2020 Perimeter Intrusion Detection System Assignable Cause Report Pie Chart provides Assignable Cause distribution of one or more zones by period This example graph shows the breakdown of Assignable Causes for all Alarms reported on 6 21 through 6 25 Assignable Cause Report Assignable Cause by Period by Type Start Date 6 21 2010 End Date 6 25 2010 Alarm Type Alorm Mizane 1 WiZone 2 Gate 34c Mi zone 14 Mi zone 15 izone 16 Micate 40 Mi zone 17 Mizone 18 i Zone 19 lZone 20 izone 21 izone 22 Gate 41 Mi Zome 23 Mi Zone 24 Mi Zone 25 Mi zone 26 Zone 27 Vi zone 28 Zone 34 Mi Zone 41 Assignable Causes System Status Changes by User and Period Bar graph provides System Status changes by User by Period This example graph shows the breakdown of Status Changes by ISC User System Status Changes by User by Period Infinity 2020 Perimeter Intrusion Detection System Site Activity Report All alarm reporting and system status information is written to a local database on the application s computer This information can be retrieved via the Site Activity Report The events are date and time stamped for analysis and period filtering The reports can also be Printed to an Adobe pdf format or Exported to Microsoft xls format When the menu option for the Site Activity Report is selected the user is prompted for Start and End Dates The report is then generated by mouse cl
5. NotePad Entry Infinity 2020 Perimeter Intrusion Detection System A Short Description and a large Notes field are available for a specific entry Select Save to store the current system note The Status field allows notes to be marked Inactive or Deleted if they are not relevant any longer Note Pad NotePad Information Gi Short Description Repaired signage Status Active Notes Tied down sign on Zone gl Standard Graphical Reports Graphical Reports provide a quick efficient method for alarm and site activity trending analysis The application provides five standard graphical reports Alarm Event Occurrences by Zone Bar Graph provides Alarm Short and Open event totals over a given period for a particular zone This example graph illustrates a total of 6 Alarms over week period for Zone 19 Alarm Event Occurences by Zone Infinity 2020 Perimeter Intrusion Detection System Alarm Event Occurences by Zone and Type Line Graph provides Alarm or Short or Open event totals over a given period for a particular zone This example graph illustrates a total of 6 Alarms over week period for Zone 19 Alarm Event Occurences by Zone and Type 0608 2070 DG 0S 2010 08 1 1 2010 Zone 19 Alarm Alarm Frequency by Period and Type Pie Chart provides Alarm frequency by type Alarm Short or Open by date This example graph reveals a breakdown of the Alarms reported on 6 21 2010 and their frequency Zone Type
6. When the main site page is first loaded the System Status will be inactive as indicated by the red colored system activity icon System initialization gets under way by a mouse click on the Start System button When this occurs the application will prompt the user to ensure the system Is to be started Message from webpage J Are you sure you want to start the system Cancel As the system settings are being downloaded to the Vision Card s the system activity icon becomes colored yellow SYSTEM STATUS When this process is complete the system is fully active allowing for full site monitoring and control as indicated by the green system status activity icon SYSTEM STATUS A Note on Stopping the System Closing the browser window alone in the typical manner does not stop the communications from the application to and from the Vision Card s In fact if the browser window were closed without stopping the system and alarms occurred thereafter they would be reported to the user after re login Simply mouse click on the Stop System button to terminate communications with the system Again the user will be prompted to ensure the system is to be stopped Message from webpage J Are you sure you want to stop the system Cancel 6 Infinity 2020 Perimeter Intrusion Detection System Sidebar Menu The Sidebar Menu provides all users access to the various features of ISC s Perimeter Intrusion Detection Syste
7. Alarm Perimeter Fence New W 0 R 0 ALARM SERVICE NRO Controller Transponder 1 Transponder Communication Notice Clear Testing W 0 R 0 NRO Controller Transponder 1 Transponder GUI Communication Notice Acknowledge W 0 R 0 bit master ja NRO Controller Transponder 1 Transponder Communication Notice Acknowledge W 0 R 0 NRO Controller Transponder 1 Transponder ALARM SERVICE Communication Notice W 0 R 0 master Developer Zone 2 Alarm Perimeter Fence Clear Testing GUI 0 R 0 Developer Zone 2 Alarm Perimeter Fence Acknowledge W 0 R 0 Developer Zone 2 Alarm Perimeter Fence New W 0 R 0 ALARM SERVICE 3 3 8 888 E 3 3 3 3 3 Rl Infinity 2020 Perimeter Intrusion Detection System The Site Activity Report can be saved electronically to be printed at a later date or exported to a spreadsheet for additional sorting and analysis Site Activity Report site Activity Report Start Date End Date search Id 4 i jof2 gt DI Find next Printing Site Activity Reports Selecting the Print button saves the Site Activity Report to a Portable Document File pdf This file is automatically saved to the path C Inetoub wwwroot ISCGU Web Print and named SiteActivity followed by the date and time it was generated A shortcut is available on the Desktop for ease of access Exporting Site Activity Reports Selecting the Export button saves the Site Activity Re
8. atus Secure Alarm Type Alarm Conditional on Zone Select Triggering on Zone Select Period 10 v Vibration 200 a ed Wind 30 g Precipitation Audio Zone Alarm Browse Copy Sensitivity Data Scheduling Zone Status There are times when site personnel may want to schedule zone status changes for authorized entry thereby eliminating nuisance alarms To create a schedule for Zone 1 select the Edit for this entry under the Schedule heading Zone Setup IX Zones Listing Controller 1 Controller Transponder 1 Transponder 1 t Zone 1 Yes Secure Main Alarm 2 Zone2 Yes Secure Main Alarm 3 Zone 3 Yes Secure Alarm iZone 4 Yes Secure Alarm Edit 5 Zone 5 Yes Secure Main Alarm Edit 6 izone6 Yes Secure Main Alarm Edit 7 Zone 7 Yes Secure Main Alarm Edit 8 Zone 8 Yes Secure Main Alarm Infinity 2020 Perimeter Intrusion Detection System The Zone Schedule Listing appears as follows fone Setup Zone Schedule Listing Controller 1 Transponder 1 Zone Add New Zone Schedule No Zone Schedule Entry Found Controller Transponder 1 Zone 1 Back Select Add New Zone Schedule since there are not currently any scheduled events for this Zone For this example site personnel have authorized deliveries daily from noon until 1 p m This is configured by entering the Start Time status change On Start Stop Time status c
9. authorized entrance into an enclosure is detected via a Tamper Switch and reported as a Tamper Alarm Other types of processor alarms include communication issues Controller and Transponder s Offline as well as AC Power Fail and Low Battery related to processor power issues Mouse clicking on the rectangular processor icon provides the current status of that processor Current Status of Processor 1 Processor Status x pa a tus Description Controller Online Controller AC Power Fail Controller Tamper Alarm Controller Low Battery Alarm Transponder i Online Infinity 2020 Perimeter Intrusion Detection System Zone Alarms When any alarm event occurs the Alarm Queue button flashes red to green alerting the user of an active system alarm ALARMS An audio message also accompanies all alarm events In the case of a zone alarm the audio message of Alarm Perimeter Fence is played until the alarm is acknowledged The zone graphic for that particular zone in alarm will also flash from red to green until acknowledged Here Zone 2 is in Alarm ALARM By mouse clicking on the Alarm Queue button the user can see the additional date time stamp and weather information which further details the Zone 2 Alarm Event Alarm Queue x ss Description Date Wind Rain Ack Clear Zone 2 Alarm Perimeter Fence Alarm 8 10 2010 9 59 17 AM 0 jo Infinity 2020 Perimeter Intrusion Detection System Process
10. e process of clearing the Zone 2 alarm having given Testing as the assignable cause Alarm Queue Clearing Zone 2 Alarm Perimeter Fence Alarm E lear Testing Close Finally the application posts that the alarm was successfully cleared Alarm Queue IX Successfully Cleared Alarm r Infinity 2020 Perimeter Intrusion Detection System The process for acknowledging and clearing processor type alarms operates in the same manner Here the West Processor has Transponder AC Power Fail alarm event Here again the Processor icon and Alarm queue button flash from red to green indicator the presence of a processor type alarm INFINITY PN B mem 20 N An audio message also alerts personnel Transponder Communication Notice The site user then mouse clicks on the Processor icon which confirms the presence of the Transponder Communication Notice Processor Status Description Controller Online Controller AC Power Fail Controller Tamper Alarm Controller Low Battery Alarm Transponder 1 Offline The alarm is acknowledged by mouse clicking on the red button icon next to Transponder 1 Offline description At this point the audio message has been silenced the issue can be investigated Processor Status Successfully acknowledged the alarm Controller Transponder 1 Transponder Communication Notice Clear Select Assignable Cause Infinity 2020 Perimeter Intrusion Detection System
11. eb browser providing clear situational awareness of the sites Perimeter Security through the Web Services interface This web services interface will also provide an efficient standardized method to relay current perimeter security information to 3rd party integrators Launching the Application Since the Infinity 2020 Application is browser based the first step in starting the application is to run Microsoft Internet Explorer this is the only tested and approved web browser The application is served up on the local machine using Internet Information Services IIS and is accessed by typing http localhost iscgui in the address then depressing ENTER O F E http jflocalhost iscgui A Note on the Windows Computer Administrator Account A Microsoft Windows Computer Administrator account was created by ISC for the initial installation and current execution of this Network Application Any changes to this account will disable the execution of the application Site personnel log into this account by entering the password of infinity After the web page has loaded the user will be prompted to log in Access to various features of the system is controlled by User Roles There are 4 user roles Developer Administrator Supervisor and User The various system functions accessible to each user role will be detailed later in this document A default Administrator account is provided with the following login credentials Role Admin
12. eneineananinada 26 Alarm Event Occurences by Zone and Type u esessssssssssssssssssssssssscsesscsesscssssssessesessesessesessesesscsessesecsesussesucsesusscsussesussesecsesessesesseseaneaesseaeeneass 27 Alarm Frequency by Period and Type ccsesssssssssssssssssssssssssssssssssscsssssssssssssscssssssessssessssessssesscsesussessssessssesessessesessesessssesassesessesessesseseeseaeeseass 27 AEO DE C U ERED 8 fl a enter nee nel eet E ATEA EAA E ee ee an vee OT ere nn eee nee er E ee 28 System Status Changes by User and Period x cscbesceccsescocortcacesaxiescacecdenescartescacesieeceneriendesexiensneerua taelaaceaulesdeneciecessorlessnesraeivietele aifeueeceeesienct 28 Site Activity Report nea eset ec etc eats cnet atest etc ete cece eee eee cece eee 29 PUMP EMMY Ys SE GEILE REDON Sse seca ct cece seeec ene E ES S E A teens 30 ENP UNG Site Activity Repo pce acca geese E tacas cot ian cases eaesies pected osesvore anus axe atesessacascesctutedsaseivessaespeceactueeueeeiecateeass 30 Infinity 2020 Perimeter Intrusion Detection System Section 1 Getting Started Major points covered in this section v Technology Overview v Launching the Application Y Pertinent GUI Features Next Generation Technology Integrated Security Corporation ISC perimeter intrusion detection systems have been providing industry leading performance for over twenty years The Infinity 2020 set of next generation hardware and software leverages today s networked
13. eport Alarm Frequency by Period and Type Report Assignable Cause Report System Status Changes by User and Period Report Site Activity Report Logout Zone Status User Note Pad Alarm Event Occurances by Zone Report Alarm Event Occurances by Zone and Type Report OO Alarm Frequency by Period and Type Report Assignable Cause Report System Status Changes by User and Period Report Site Activity Report Logout r S Infinity 2020 Perimeter Intrusion Detection System Weather Status Query Each Vision Card has the capability of receiving current wind speed and rain intensity compensation information from a field mounted Weather Station Mouse down on the Weather Status button for an update of the current weather from one or more weather stations All user roles have access to this feature Alarm Queue The Alarm Queue provides a listing of the currently active alarms The user can acknowledge and clear these alarms from the directly from the queue All alarms are time and date stamped and tagged with the wind and rain information at the time of the alarm event All user roles have access to this feature Zone Status Each zone can be put in one of three arming states Secure Access and Disarm The secure state provides full alarm monitoring capability and it used by default for an active system A disarmed zone is inactive and will not report any alarm events regardless of the activity level at that z
14. f both Zone 1 and Zone 2 are in an alarm condition within 10 seconds a Zone 1 alarm is reported a t vvrnvs Infinity 2020 Perimeter Intrusion Detection System Period The Period setting designates how long in 10 second increments the Open or Short Alarm condition has to be active before it is reported Vibration Sensitivity Assigns the Vibration Sensitivity level for a zone and ranges from 1 200 where 200 is the highest sensitivity level Typical levels are 185 190 but vary depending on fence type and site conditions Wind Sensitivity Assigns the Wind Sensitivity level for a zone and ranges from 1 100 where 100 represents the highest level of compensation Typical levels are 15 20 but vary depending on site conditions Precipitation Sensitivity Assigns the Precipitation Sensitivity level for a zone and ranges from 1 100 where 100 offers the highest level of compensation Typical levels are 10 25 but vary depending on site conditions Audio Allows for customized audio notifications at each zone As an example the Vibration Sensitivity level for Zone 1 will be modified Locate the Vibration Sensitivity control and change the value to 190 A Save action is required on any change so that the new value s are sent to the hardware and verified Select Save to send the updated settings to the hardware Zone Setup Controller 1 Controller Transponder i Transponder 1 Input 1 Zonei Zone Label Zone 1
15. hange On Stop and days of the week Note for holidays or one day event schedules enter in the optional date Valid status changes are Secure Access and Disarm Select Save to complete the Zone Schedule Setup for that zone fone Setup Zone Schedule Add Edit x Controller Transponder Zone Date optional Start Time On Start Stop Time On Stop Monday Tuesday Wednesday Thursday Friday Saturday Sunday cS KS KSI SKS CK a5 Controller 1 Transponder 1 1 Zone 1 sd B 12 00w Access 13 00 Secure wW Infinity 2020 Perimeter Intrusion Detection System Section 4 System Notes and Reporting Major points covered in this section v Working with System Notes v Configuring Standard Graphical Reports v Using the Site Activity Report Notes and Reporting Features System Notes Site personnel may need to document system issues for supervisors or relay information across shifts to track issues Also notes may be added or accessed later via a search by user and date for historical purposes Simply locate and mouse click on the Note Pad sidebar menu item The Note Pad main window is presented allowing a search of existing system notes by User Date and Status This is also the same interface to add to system notes Notes are added by simply selecting Add New Note Pad Entry Note Pad Search NotePad Start Date EndDate User All Users Status Active g Add New
16. hscocteniessiencctelcacssanieninencleie excl ecnersieiceensdondaaslencnesetaenmaneniennacedeanednneimeaeeet 11 Managing Assignable Causes cccsessssssssssssssssssssssssssessssessesessssssssssesessesessssessesussesussessssesussesessesussesussesussesessesessesussesessesessesessesassesesseseessensseassaeeess 15 Section 3 Working with System Parameters asic scdesccd ca aestecseleceacaccnstacsedecsececcnatensedeseanaeusceacasdtecacaconeieesediacedseusstanielecensacceaantdeansideaelaroeet enii 16 Controller Card Configuration Settings seseessssssssesssseessseessseessseessstensseessseensstensseeossteosstensstensstensstensstenssteosstenssttosstenstenssttossteosstensstenssteosseensse 16 Transponder Card Configuration Settings 0 csesessssssssssssssssssscsssssssscssssssssssssssssesscssssssessessssesssssssssssessssessssessesessssessesesseseesesceessesessesssseeseseeseess 17 COMTIGUPING Zone ParatneterS ssns EE O E EEEE OAE 18 acme duing Z one E a E AE E AEE SEE AEA EEE ETE EEE E AE E EOE E 23 Section 4 System Notes and REPorting ccescessesssesesssssssssessesessssessssesssssssssessssessesessesessesessesessesessesessesessessssessesesessesessssessesessesessesessesessessseeeeseass 25 SS ASS OI 15 ks re ee ee eet rere ere renee ee ee ee ee eee 25 BU ei lea Go Foca ING AREO gee eae ERE ANA cc eace anaes cot races ec eee acer de osnns cea econ et E EA 26 Alarm Event Occurrences DY ZONC ancaccedncme nn denncninnsandnciianiicneuenr ae acndan nem an
17. icking on the Search button if Search is selected without dates entered all event records are provided Site Activity Report Site Activity Report Start Date i End date tu i s oft gt P 100 Pind tot Site Activity Report Here is an example Site Activity Report Site Activity Report 8 10 2010 10 15 22 AM Developer Alarm Clear NRO Controller Transponder 1 Transponder Communication Notice Clear Testing W 0 R 0 8 10 2010 10 15 13 AM master Developer Alarm Acknowiedge NRO Controller Transponder 1 Transponder Communication Notice Acknowledge W 0 R 0 qiO2010 10 1453AM master Developer UserLoggedin User Logged in 8 10 2010 10 10 58 AM master Developer Alarm Acknowledge NRO Controller Transponder 1 Transponder GUI Communication Notice Acknowledge W 0_ R 0 8 10 2010 10 09 53 AM master Devel NRO Controller Transponder 1 Transponder ALARM SERVICE Communication Notice W 0 R 0 8 10 2010 10 08 15 AM master Devel Alarm Clear Zone 2 Alarm Perimeter Fence Clear Testing GUI W 0 R 0 8 10 2010 10 06 33 AM Devel Alarm Ackn Zone 2 Alarm Perimeter Fence Acknowledge gt 0 8 10 2010 10 06 28 AM Zone 2 Alarm Perimeter Fence New W 0 R 0 8 10 2010 10 06 16 AM Alarm Acknowledge Zone 2 ala Perimeter Fence Acknowledge 8 10 2010 10 06 16 AM Devel Zone 1 Alar Perimeter Fence Clear Weather Zone 2 Alarm Perimeter Fence New W 0 R 0 ALARM SERVICE Zone 1
18. istrator Username Admin Password a Role Supervisor Username super Password s Role General User Username user Password u Infinity 2020 Perimeter Intrusion Detection System Log in to default Administrator account Enter your username and password below Username Admin Password e FORGOT YOUR PASSWORD If you forgot your password enter your e mail address below Your password will be sent to the e mail address specified in your account profile E mail Address Request Password The ISC Network Application provides the site user clear graphically based controls for straightforward system operation System functions include changing Infinity 2020 Perimeter Security System parameters responding to alarm events managing user access entering system notes defining assignable causes and querying the database for customized graphical and text based system activity reports After successful login the main site graphics page will be loaded displaying the site graphics along and with its associated perimeter security zoning The high level system controls are provided in the callouts below price re D heey Start System n TAT Mna Infinity 2020 Weather Alarm Queue gamm e m e a T ta aes if Status Query PEE po Sidebar Menu gt lt CoS Zone Setup Infinity 2020 Perimeter Intrusion Detection System Start System
19. itional zone is active Typical cases are Cond Event Rcond Event Rcond Revent CONDITIONAL The Conditional type is used for zones which are normally in an alarm state but may be accessed without alarm if an adjacent zone has experienced authorized access Most often conditional zones would be used on either side of a gate to prevent the vibrations set up by the opening and closing of the gate from creating an alarm Disturbance of the fence at any other time would produce an alarm When the Conditional type is selected the Conditional On Zone becomes active for zone selection Typical uses are Conditional Alarm and Conditional Event pairs The Remote Cond Rcond alarm type acts similarly but does not allow the alarm relay to energize if the Conditional Event or Revent is active DUAL The Dual alarm type is an alarm condition that would require two zones to be in alarm within a software programmable time period before an alarm is reported to site personnel An application of this would be the use of an interior microwave and an ISC perimeter fence sensor requiring both to be in alarm within a ten second window in order to report an alarm at the GUI TRIG The Trigger alarm type is used in conjunction with the Dual alarm type to act as the trigger zone that must be alarmed before the Dual zone to generate an alarm condition at the host For example Zone 1 is set to a Dual type triggering on Zone 2 with a period of 10 seconds That is i
20. ltered without factory support m Infinity 2020 Perimeter Intrusion Detection System Configuring Zone Parameters Changes to zone parameters can be accomplished via the GUI or the Sidebar Menu Since the GUI Is easier to relate to and more direct this method will be detailed first All Zone Parameters can be found in the Zone Setup Window To view these parameters you must be logged in with an Administrator Role Simply mouse click on the graphical zone of interest here Zone 1 to view the current settings fone Setup Controller 1 Controller Transponder 1 Transponder 1 Input 1 Zonei Zone Label Zone 1 Active yes Ono Region Main v Status Secure v Alarm Type Alarm i Conditional on Zone Select Triggering on Zone Select Period 10 v Vibration 200 Wind 30 a Precipitation 20 a al Audio Zone Alarm Browse Copy Sensitivity Data The following is a brief description of the Zone Parameters and typical settings Controller Controller number and name Transponder Transponder number and name Input Vision card input number and name Zone Label Zone name r Infinity 2020 Perimeter Intrusion Detection System Active Default setting Yes if made inactive Zone Alarm relay and Vision Card alarm messages are disabled Region GUI Region Zone alarm reports to configured by ISC personnel Status The default setting is Secu
21. m The Sidebar Menu becomes visible by mouse clicking on the long vertical control bar on the left hand side of the screen For full unobstructed site monitoring mouse click on the control bar again and the Sidebar Menu closes The menu features available change depending on the user s defined Role There are three site user roles Administrator Supervisor and User An ISC factory defined role Developer is provided for initial graphic site development and to modify application performance parameters Only the Developer role has access to the Manage Regions and Manage Application Configuration features Note it is extremely important that site administrators consult with the technical support team at ISC before making any Developer setup parameters Doing so may result in severe system degradation This menu lists the features available to the administrator role Administrator Manage Processors Manage Controllers Manage Causes Manage Users Note Pad Alarm Event Occurances by Zone Report Alarm Event Occurances by Zone and Type Report Alarm Frequency by Period and Type Report Assignable Cause Report System Status Changes by i User and Period Report Site Activity Report Logout Zone Status Zone Setup Infinity 2020 Perimeter Intrusion Detection System A breakdown of systems features based on role is provided below Supervisor Note Pad Alarm Event Occurances by Zone Report Alarm Event Occurances by Zone and Type R
22. nu select Manage Controllers to display the Controllers Listing page then select Edit under the Transponder heading Manage Controllers Controller Listing Controller Serial eye port After this selection has been made the sites Transponder Listing will become available Manage Controllers Transponder Listing Controller 1 NRO Controller Transponder 1 To view the current Zone parameters for Transponder 1 select the Edit under the Zones heading The Zones Listing for Transponder 1 is now available for review To edit Zone 1 zone parameters simply select the Edit to the left of the Input 1 Zone Setup zones Listing Controller 1 Controller Transponder 1 Transponder 1 Input Name Activated At Startup Region Alarm Type Period Vibration Wind Precip Schedule Edit t Zone 1 Yes Secure Main Alarm 10 190 Edit 2 Zone 2 Yes Secure Main Alarm 10 200 Edit 3 Zone 3 Yes Secure Main Alarm 10 200 Edit 4 Zone 4 Yes Secure Main Alarm 110 200 Edit 5 Zone 5 ves Secure Main Alarm 10 200 Edit 6 Zone 6 Yes Secure Main Alarm 10 200 Edit Zone 7 Secure Main Alarm 110 200 Edit z Zone 8 Yes Secure Main lAlarm 10 200 Infinity 2020 Perimeter Intrusion Detection System This then displays its current zone settings fone Setup Controller 1 Controller Transponder i Transponder 1 Input 1 Zonei Zone Label Zone 1 Active yes Ono Region Main St
23. one There are also three types of Zone alarms which can be reported Alarm Short and Open Alarm is reported on a typical intrusion type disturbance fence climb For severe system tampering alarm events such as cutting the sensor line or tying it to an electrical ground Open or Short is respectively reported When a zone is placed in the access state only Short or Open alarm events are reported Supervisor and Administrator roles have access to this feature Zone Setup All zone parameters can be easily viewed and configured via the zone graphic representation Site personnel simply mouse click on the zone of interest to reveal it currents settings or change any of its parameters Zone Setup parameters include Zone Status Alarm Type Period Vibration Sensitivity and Wind Precipitation Compensation The Administrator role has access to this feature Infinity 2020 Perimeter Intrusion Detection System Section 2 Site Alarm Reporting and User Interaction Major points covered in this section Y GUI Presented Alarm Events Acknowledgement and Clearing of Alarms v Managing Causes GUI Alarm Events Alarm Event Types There are 2 categories of alarm events Processor and Zone Zone alarms represent those related to fence line intrusions and can be reported as Alarm Short or Open as described earlier Processor type alarms relate to component issues found in enclosure mounted hardware For instance un
24. or alarms report in the same manner as a zone alarm providing both a visual and audio alert Here the Processor P1 has an alarm indicated by the red to green flashing processor icon INFINITY WEATHER ALARM ee PEMMETER Infinity 2020 2 S N SYSTEMS Mouse clicking on the processor icon reveals the particular type of processor alarm here a Transponder 1 Communication Notice Alarm Again more details on this alarm can be found in the alarm queue Alarm Queue ms Description Date Wind Rain Ack Clear Controller Transponder 1 Transponder 8 16 2010 9 0 aS Communication Notice 10 02 09 AM Close Acknowledging alarms is graphically driven with the user mouse clicking either on the flashing zone icon or the Ack Clear link provided next to the alarm in the queue Once acknowledged the flashing states change from red and green to yellow and green and the audio associated with that alarm is silenced Here the Zone 2 alarm has been acknowledged Infinity 2020 Perimeter Intrusion Detection System PIDS Demonstration Successfully acknowledged the alarm Zone 2 Alarm Perimeter Fence Alarm Once the source of the zone disturbance has been investigated and determined the user selects the assignable cause in the pull down and then simply mouse clicks on the Clear button Note that the application will not allow a clear action without an assignable cause selection The illustration below shows the application in th
25. port to a Microsoft Excel Spreadsheet xls This file is automatically saved to the path C Inetoub wwwroot ISCGUI Web Export and named SiteActivity followed by the date and time it was generated A shortcut is available on the Desktop for ease of access
26. re In this state all alarm conditions are reported Conversely when a particular zone is put in the Disarm state reporting of all alarms conditions is suppressed The Access state is provided to suppress the reporting of the Zone Alarms but allows Zone Open and Zone Short alarm types to be reported Site personnel can use this feature short term for authorized gate activity as a way to minimize nuisance alarms with the advantage of knowing if any tampering occurs by a physical cut in the sensor line or tying the sensor line to an electrical ground Alarm Type ALARM With the Alarm type any alarm condition in that zone will cause the system to report that an alarm has occurred This is the default setting and would be used for the majority of the perimeter fence The Period setting designates how long in seconds the Open or Short Alarm condition has to be active before it is reported EVENT In the Event type a condition that would ordinarily create an alarm is recorded but does not produce an audio or visual indication at the GUI For instance a gate which is used for authorized access can be set as an Event zone The Site Activity Report still maintains a record of every authorized access along with the date and time that it occurred From a hardware standpoint the zone relay outputs still maintain the operation of an Alarm type The Remote Event Revent alarm type acts similarly but does not allow the alarm relay to energize if the Cond
27. t these parameters not be altered in any way without first consulting with the technical support team at ISC Doing so may cause permanent connectivity issues from the application to the Vision Card thereby essentially disabling the system Transponder Card Configuration Settings To view the setup parameters of Transponders select Edit located under the Transponder heading Manage Controllers x Controller Listing l Num Name Type Atlee Zones Unattended Mode Trans Edit 1 Controller Serial Sport k ji No Edt After this selection has been made the sites Transponder Listing will become available Ld Manage Controllers Transponder Listing Controller 1 NRO Controller Assigned Weather Zones Y Edit 4 a 3 i a O 3 a m a lt Select Edit on the left hand side of the Transponder of interest to view its current setup parameters Manage Controllers Ix Transponder Information Controller 1 NRO Controller Name Transponder 1 Transponder Num 1 Processor Processor 1 Weather Station yes Ono Weather Station Name NRO Weather StatusID Active w Alarm Source Audio Communication C Browse Tamper Browse AC Power Fail C Browse Low Battery Alarm All Transponder parameters listed are used by the application and should not be a
28. technology while maintaining the same performance reliability and trouble free maintenance our customers have come to know and expect Network Application Browser Based The Internet Age has provided explosive growth and greater efficiency in all areas of our world Devices can now be easily deployed within existing secure private networks and interrogated from any networked PC The figure below provides an overview of the ISC s typical networked system configuration Infinity 2020 Next Generation Architecture Secure Communication Driver ISC Browser GUI Network Cabl Vision Card IP Addressable 16 Zones Web Services 4 Infinity 2020 Perimeter Intrusion Detection System The Vision Card monitors up to 16 field mounted sensor cable inputs and reports alarm activity over TCP IP encrypted Ethernet communication links copper or fiber to a network PC running the Infinity 2020 Network Application The Vision Card can function as a Controller or a Transponder The Controller periodically interrogates one or more transponders and passes any alarm events to the application Transponders monitor Sensor Line activity to detect intrusions and pass them to the Controller The Vision Card which is configured as the Controller also has an on board Transponder The application is comprised of several Windows based alarm services some of which write system activity to the ISC database The site monitoring and control GUI is accomplished via a w
29. tivate current assignable causes which may not be relevant any longer via the Status selection gt Infinity 2020 Perimeter Intrusion Detection System Section 3 Working with System Parameters Major points covered in this section v Vision Card Configuration Settings y Understanding and Changing Zone Parameters v Creating Scheduled Zone Status Events Vision Card Parameters Controller Card Configuration Settings In most applications ISC will design configure and test all final hardware parameters for the site It may be helpful to know where the settings are for future reference Key hardware setup information can be found under the Manage Controllers option under the sidebar menu Select Edit on the left hand side to view the Controller setup parameters Manage Controllers x Controller Listing Add New Controler Num Name i Type Active Zones Unattended Mode Trans Edit 1 I Controller Serial 8 port a No Edit Key parameters that the application uses include Controller Number Processor Controller Type Port Number COM Port Unattended Mode Status Alarm Source and Audio The balance of the fields is for informational purposes only Controller intormaton ED C Cati erter Breer yp hey Gar te Desci Say Carre ston eum ieee ac Dweet fae En Low Batter Awr eeee Infinity 2020 Perimeter Intrusion Detection System It is highly recommended tha

Download Pdf Manuals