1. AGLGD Usermanual Page 4 To set the watering frequency turn the FREQUENCY selector to the required position every 8 12 or 24 hours or 2 3 4 or 7 days For Multipla AC 230 24V LCD p n 8058 To start the programme immediately press START once The next watering cycle will begin after the time period set with the FREQUENCY selector has elapsed example pressing the START button at 20 00 to activate the programme with the FREQUENCY set at 8 hours the next watering cycle will start at 04 00 oO VV For Multipla AC 230 24V LCD p n 8058 GlaGeErR MultiplaAGLGD Usermanual Page 5 To delay the start of the programme press START a second time before 5 seconds have elapsed to set a delay of one hour a third time for two hours and so on up to 23 hours The display temporarily indicates the number of hours delay selected then the watering standby signal appears along with the time remaining until the start of the first cycle Q For Multipla AC 230 24V LCD p n 8058 When a watering cycle is in progress the display shows the ongoing symbol the number of the line currently active and the number of minutes remaining until watering is due to finish on that line The valve currently open is also indicated by the relative Led which blinks Once completed the watering cycle the standby signal reappears in the display with the time remaining until the start of the next watering cycle example of wa
2. GlaGeErR MultiplaAG LGD Usermanual Page 1 Fix the timer to a wall in a covered location sheltered from weather and splashing water ambient temperature between 0 and 50 C Do not install the timer outdoors or in underground valve box 0 oo OK 0g RIAAN 6 bo i J A A sa yeg A DIY A l N go Obey LO wary eer max 50 C a b For Multipla AC 230 24V LCD p n 8058 Electrical connections MULTIPLA AC 230 24V i 9Volt ALCALINA junction box max 50 m cross section 1 5 mm g a m m m m a l wf ee MH MH N m m m m m o a ww l l wm amp J Rain cine Sensor to pump optional 220 V Claber relay For Multipla AC 230 24V LCD p n 8058 GlaGeErR MultiplaAGLGD Usermanual Page 2 Remove the cover of the battery pocket from its seat connect the battery and position it in the pocket with a light pressure Use only a new 9 volt alkaline battery type IEC 6LR61 When the battery is inserted the message OFF will be displayed For Multipla AC 230 24V LCD p n 8058 Refit the battery cover Plug the voltage transformer into a 230 V AC mains power socket The battery serves purely to maintain the clock function and therefore the timing of the selected programme in the event of a mains power failure For Multipla AC 230 24V LCD p n 8058 GlaGeErR MultiplaAGLGD Usermanual Page 3 The test function can be us
3. ed to perform a quick check on the system that will ensure its correct operation by activating a given valve manually for a preset duration of 5 minutes If there is a watering cycle in progress it can be interrupted by pressing TEST and START Press the TEST button repeatedly to select and activate one of the lines after a few seconds the relative valve will open for 5 minutes The display indicates the operating mode TEST the line selected and the time remaining To close the valve being tested before the end of the 5 minu tes press TEST and START simultaneously 2 For Multipla AC 230 24V LCD p n 8058 During a watering cycle the Multipla activates all the valves on lines 1 to 6 for which a watering time has been programmed using the LINE SELECTORS opening them in succession and in ascending order A watering programme consists in the repetition of a watering cycle at intervals programmed with the FREQUENCY selec tor Having decided which lines are to be activated turn the LINE selector for each one until it is positioned on the required time Watering can be programmed for a duration between 5 and 60 minutes To exclude watering ona given line position the corresponding selector on e zero NL led valve 1 a ea Line 1 led valve 2 X EM led valve 3 X 7 0 led valve 4 X tn led valve 5 X mn sdy led valve 6 a ae Line 2 Line 3 For Multipla AC 230 24V LCD p n 8058 GlaGeErR Multipla
4. ent to the change being made thereafter the watering cycles will be repeated at the new frequency selected whilst the START time remains unchanged Lm from 8h to 12h from 10 min to 20 min O x b 24h from 10 min to 20 min Frequency For Multipla AC 230 24V LCD p n 8058 GlaGeErR MultiplaAGLGD Usermanual Page 7 The STOP function interrupts the watering cycle currently in progress Watering will restart as normal with effect from the cycle following the selected pause as programmed by positioning the FREQUENCY selector The STOP function can also be used to close a valve manually when activated in TEST mode Q For Multipla AC 230 24V LCD p n 8058 The RESET function closes the valve if currently open and switches the timer OFF Watering will be suspended until the START button is pressed again or until a TEST is run To RESET the timer press the START and START buttons simultaneously and hold them for 5 seconds The message OFF appears in the display Q RESET NA y 2 lt gt SEC P caf A Z 20 14 UA sl 10 ka 45 sil 40 For Multipla AC 230 24V LCD p n 8058 For more information and further details please consult the instruction manual supplied with the product
5. tering cycle with FREQUENCY selector set to 8h 2 Example of watering cycle with FREQUENCY selector set to 8h sly OO led valve 1 For Multipla AC 230 24V LCD p n 8058 GlaGeErR MultiplaAGLGD Usermanual Page 6 Example of programming at 16 30 the duration is selected for all of the watering lines LINE selectors and the frequency is set at 8h FREQUENCY selector Suppose that watering is not required immediately but at 22 30 i e after 6 hours press the START button once and then six times in succession so that the display shows 6 00 The time indicated in the display begins counting down reaching 0 00 at 22 30 the watering cycle starts and will then be repeated every 8 hours as set with the FREQUENCY selector i e at 22 30 at 06 30 and at 14 30 OD cx 2 Frequency For Multipla AC 230 24V LCD p n 8058 To change a watering programme currently in use enter the new LINE and FREQUENCY settings as required The change will be effective by the timer when appropriate Examples with watering in progress and line 2 active the position of the LINE selectors is changed e g from 10 min to 20 min there will be no change on the duration of the watering step already in progress on line 2 whereas the new setting of 20 minutes will be effective with the activa tion of line 3 changing the position of the FREQUENCY selector say from 8 to 12 hours the new setting will take effect within 24 hours subsequ