Contents

1. a Table PEDStatus A Sam uas u sa ua i Table 6 Communications and Wiring RHYL RHY ELYN THYN FYDR YDDYN DD DD DDYDD FN Table 7 Reader Wirimge sine dae Table 8 Troubleshooting Problems and Solutions a NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A x www honeywell com NetAXS NX4S1 Installation 1 0 Notices 1 1 Warnings and Cautions A A Warning Fire Safety and Liability Notice Never connect card readers to any critical entry exit door barrier elevator or gate without providing an alternative exit in accordance with all fire and life safety codes pertinent to the installation These fire and safety codes vary from city to city and you must get approval from local fire officials whenever using an electronic product to control a door or other barrier Use of egress buttons for example may be illegal in some cities In most applications single action exit without prior knowledge of what to do is a life safety requirement Always make certain that any required approvals are obtained in writing Verbal approvals are not valid Warning Honeywell Access Systems HAS never recommends using WIN PAK or related products for use as a primary warning or monitoring system Primary warning or monitoring systems should always meet local fire and safety code requirements The installer must al
2. 36 www honeywell com NetAXS NX4S1 Installation System Configuration 5 11 M 56K Dial up Modem RS 485 Connection via NetAXS Thirty one NetA XSTM Access Controller panels for each drop line It has not been reviewed by UL Figure 27 M 56K Dial up Modem RS 485 Connection via NetAXSTM M 56K i FAX MODEM N a COM Port Straight Through Cable al Analog n Remote DIP Switch Settings Phone Female 9 Pin Male 25 Pin 1 3 8 ON 2 4 5 6 7 OFF Line Terminal RX 2 3 RX TX 3 gt 2 TX Dedicated Comm 5 e gt 7 Comm M 56K analog FAX MODEM phone line Y recommended CBL50 Male 9 Pn lt Male 25 Pin i llOOO 6 RS 232 50 ft Remote DIP Switch Settings 1 3 8 ON 2 4 5 6 7 OFF RS 485 4 000 ft DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37 OPEN DIP Switch Settings S1 S5 Panel Address S6 ON J36 CLOSED J37 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J37 CLOSED NetAXS Panel i i See RS 485 Cable Note l It is recommended to EG Earth Ground EG EG each NetAXS enclosure Individually DB 9 DB 25 Connectors RS 485 Cable g Female NetAXS Panels A TB7 1 RS485 TB7 2 RS485 TB7 3 RS485 COM 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HA
3. 60 www honeywell com NetAXS Standalone Operation NetAXS M Panel Defaults A 4 5 Door Status Inputs The panel has a Door Status input for each door The default condition is a two state input configured as a Normally Closed contact The following are the default door status input associations Door Status input Panel input Reports as 1 SP2 Input 2 1 SP4 Input 4 1 SP6 Input 6 1 SP8 Input 8 A 4 6 ACFAIL and Panel Tamper Inputs The panel has the following two additional generic inputs that can be used as generic inputs or as either External Power Fail or Enclosure Tamper inputs The default condition is a two state input configured as Normally Closed Input 14 is a special case since it reports in as two inputs inputs 14 and 20 Input 14 can be used as a generic input but input 20 is used for the Enclosure Tamper alarm An active External Power Fail input indicates that the system is operating from the battery current not from the primary input power An inactive External Power Fail input indicates that the system is operating from the primary input power Generic input Panel input Reports as Generic External Power Fail SP9 Input 13 Generic Enclosure Tamper SP10 Inputs 14 and 20 NetAXS Access Control Unit NX4L1 Installation Guide 7 901099 Revision A 61 NetAXS Standalone Operation NetAXS Panel Defaults A 4 7 Additional Generic Outputs The
4. 7 GND 7 GND 34 www honeywell com NetAXS NX4S1 Installation System Configuration 5 9 RS 232 Short Haul Modem Connection One NetAXS Access Controller panel for each loop It has not been reviewed by UL Figure 25 RS 232 Short Haul Modem Connection RS232 Cable MODEM PC DTE DCE DB 9 Straight Null RS 232 50 Ft Max 2TX gt 2 TX 2 RX a 3RX 3 RX or 3 TX WE 5 Comm lt 7 GND 7 GND Terminal SHM B ASYNCH Short Haul Modem je y DCE ODN o ac O lt Jumper SRF _ ODIs DEC DTE gt id is pa m J lt S2 Loopback DIP Switch Settings S1 S5 Panel Address 5279 9 S6 OFF Foot lt S2 Loopback U J DEC DTE gt RTSIDTR CONTROL ODN O lt Jumper ODIS It is recommended to Earth Ground EG each Oo SHM B ASYNCH Uw B lt J1 RS 232 Connector NetAXS enclosure Short Haul Modem individually a RS232 Cable MODEM PC DTE DCE RS 232 50 Ft Max DB 9 Straight Null Male 9 Pin v Male 25 Pin 2TX 2 TX 2 RX 3RX R 3 RX or 3 TX 5 Comm gt 7 GND 7 GND NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 35 NetAXS NX4S1 Installation System Configuration 5 10 M 56
5. ydw RS 485 Connection via NetAXS a data Maa RS 485 Connection via NetAXSTM with Multidrop Panels at Both Ends RS 485 Connection via PCI 2 with Multidrop Panels at Both Ends RS 232 CONNECTION uc unu S see elses A tee ee Ethernet Connection tata anan aqu qa Fad ne ataq ans YD Aa LANSREUJTC Onn COs u ia RS 485 Short Haul Modem Connection via PCI 2 RS 485 Short Haul Modem Connection via NetAXS RS 232 Short Haul Modem Connection ieir III Lein M 56K Dial up Modem RS 485 Connection via Hub M 56K Dial up Modem RS 485 Connection via NetAXS Fiber Converter to RS 485 Connection via PCI 2 Fiber Converter to RS 485 Connection via NetAXS N 485 PCI 2 NetA XSTM Access Controller Panel Connection Detail NetA XSTM NetA XSTM Access Controller Panel Connection Detail System Relay and Power LEDS Aa NX 451 Panel Wiring Dira A CB ads NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A vii viii www honeywell com LIST OF TABLES able Reader Wiring ieu t Lu DI Susa s davon asas R asas Table 2 Default Supervised Input Assignment n aa Tabl 3 DIP Switch Setitis cidcid tidad data td E EE idad saves Table 4 MIRO 32 0 DIP Switch and Jumper Settings
6. N RS 232 Ethernet S 2 8 E ion RS485 B F xpansion el Host RS485 187 Expansion RS485 h J 5 z a Buzzer OUT 17 LED OUT 11 DIP switches mpor 1 5 a DO 56 Common 3 D1 D1 3 Common DO 12VDC LED OUT 13 Tamper IN 9 Buzzer OUT 16 Buzzer OUT 15 Tamper IN 12 LED OUT 12 H2VDC y A DO TB12 Common 9 5 D1 D1 9 8 Common D0 x 2 12VDC Tamper IN 10 EDITA Buzzer OUT 16 DR3REXINS a Door1 REX IN 1 Common DR3 Status IN 6 2 P Common TB13 S 53 Door1 Status IN 2 Au 7 a z ae Door2 REXIIN 3 Common i Common DR4 Status IN 8 O Door2 Status IN 4 Aux Common 8 O 2 gt gt ens Aux 12VDC ER a Aux Common Relay 5 N C Relay 1 N O Relay 5 Com o A to Relay 1 Com Relay 5 N O 6 cs Relay 1 N C TB2 TB15 Relay 6 N C a a8 Relay 2 N O Relay 6 Com 2 86 Relay 2 Com Relay 6 N O Q Relay 2 N C Relay 7 N C un Relay 3 N O Relay 7 Com N tty Relay 3 Com Relay 7 N O 5 os Relay 3 N C TB16 Relay 8 N C 5 s Relay 4 N O Relay 8 Com O ao a a Relay 8 N O s elay 4 N C ACIDC Va AC DC lt Battery CASIL CA1270 Power LED HAS 3 000066 12VDC 7AHr Note Maintain at least a 25 inch distance between the non power limited wiring battery B backup charger wiring and all other wiring which is power limited Class 2 wiring NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 47 NetAXS NX4S1 Installation Maintenance 8 0 Maintenance N
7. TB1 3 RS485 COM gt TB1 1 RS485 TB1 2 RS485 Fiber RXD DIP Switch Settings S1 S5 Panel Address S6 OFF Fiber TXD Rs 485 Negative RS 485 Crain Wire to earth ER J36 CLOSED Fiber RXD J37 CLOSED i Fiber Cable PE Fiber TXD 10 000 Ft Fiber Cable 10 000 Ft FC485 RS 485 Fiber Converter RS 485 Drain RXD not connected here PWR connected at panel side TXD FC485 NetAXS Panel RS 485 Fiber Converter i TB1 3 RS485 COM 7 1 lt TB1 1 RS485 4 TB1 2 RS485 NetAXS Panel p TB1 3 RS485 COM 1 RS 485 Comm TB1 1 RS485 r RS 485 Positive TB1 2 RS485 CD Rs 485 Negative Fiber TXD ls j Fiber TxD EG It is recommended to Earth Ground EG RS 485 Cable each NetAXS enclosure Individually NetAXS Panels TB7 1 RS485 TB7 2 RS485 TB7 3 RS485 COM DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37 OPEN 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 39 NetAXS NX4S1 Installation System Configuration 5 14 N 485 PCI 2 NetAXS Access Controller Panel Connection Detail This diagram has not been reviewed by UL Note that PCI 2 units can also be wired anywhere along the drop line See Figure 18 on page 28 and Figure 19 on page 29 Figur
8. 24VDC wn JPi OFF TB5S6 l ADDRESS 5 EXTERNAL 2VDC A El swr Au zon JP1 ON 24V Return ADDRESS 6 NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 25 NetAXS NX4S1 Installation System Configuration 5 0 System Configuration This section provides wiring diagrams for each of the NetAXS M system configurations 5 1 RS 485 Connection via PCI 2 This connection supports thirty one NetAXS Access Controller panels for each drop line It has been reviewed by Underwriters Laboratories Incorporated UL Note that PCI 2 units can also be wired anywhere along the drop line See Figure 18 on page 28 and Figure 19 on page 29 Because UL has reviewed the NetAXS M panel only as a standalone system the computer terminal NetAXSTM gateway panel and N 485_PCI 2 adapter appear in this section only to illustrate the installation and programming of the NetAXS M panel Figure 16 RS 485 Connection via PCI 2 COM Port RS 232 50 Ft Max RS 485 4 000 Ft N 485 PCI 2 Refer to N 485 PCI 2 NS2 NS2 000 Access Controller Panel Connection Detail diagram Terminal DIP Switch Settings RS 485 Cable ST ON RS485 NetAXS Panels S2 ON Red White TB7 1 RS485 53 ON Black Green TB7 2 RS485 54 ON RS 485 COM TB7 3 RS485 COM S5 ON S6 ON Ack Nak Enable 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with 5 ON ao BYR Er
9. C pn code time zone dev lt CR gt Variables pn panel number 1 31 code card number range depends on card format time zone time zone number the card will follow 1 255 dev device numbers card will work with see below 1 card reader 1 2 card reader 2 3 card reader 3 4 card reader 4 Example 1 _C 6 12345 10 1 2 3 4 lt CR gt This command would configure panel 6 to add a card entry of 12345 to the panels database that will be valid on reader 1 2 3 and 4 during the times and days specified by time zone 10 Example 2 _C 18 52989 120_1_3 lt CR gt This command would configure panel 18 to add a card entry of 52989 to the panels database that will be valid on reader 1 and 3 during the times and days specified by time zone 120 A 3 5 C Card Delete Command _C pn code lt CR gt Variables pn panel number 1 31 code card number range depends on card format Example 1 _C 6_12345 lt CR gt This command would remove card 12345 from panel 6 Example 2 _C 18_52989 lt CR gt This command would remove card 52989 from panel 18 56 www honeywell com NetAXS Standalone Operation Standalone Commands A 3 6 W Input Command _W pn_input_ SO SC NO NC lt CR gt Variables SO Supervised normally open SC Supervised normally closed NO Non supervised normally open NC Non supervised normally closed default Example _W 1_9 SO lt CR gt Input 9 has been progra
10. shield 120 ohm 23 pf HAS part no NCP2441 TN S8 OFF 19 200 Baud Rate HY DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J3 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37 OPEN NetAXS Panel It isrecommended to Earth Ground FG each NetAXS enclosure individually Only Earth Ground EG one side of cable EG EG 26 www honeywell com NetAXS NX4S1 Installation System Configuration 5 2 RS 485 Connection via NetAXS This connection supports thirty one NetAXSTM Access Controller panels for each drop line It has been reviewed by UL However because UL has reviewed the NetAXS panel only as a standalone system the computer terminal and NetAXS gateway panel appear in this section only to illustrate the installation and programming of the NetAXS panel Figure 17 RS 485 Connection via NetAXS COM Port RS 232 50 Ft Max RS 485 4 000 Ft Terminal Refer to NetAXS NetAXS _ Panel Connection Detail diagram DIP Switch Settings 51 55 Panel Address S6 ON J36 CLOSED J37 CLOSED RS 485 Cable NetAXS Panel TB7 1 RS485 TB7 2 RS485 TB7 3 RS485 COM 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J37 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37
11. 2 Standalone Settings A 2 1 NetAXS Panel Hardware Settings Configure the system with an RS 232 connection according to Figure 20 on page 30 Set DIP switches 1 through 5 to define the panel number see Table 3 on page 22 Panel number 0 is not valid Set DIP switch 6 to the OFF position to place the panel into the Multidrop mode Use a personal computer s serial communications port COM1 or COM2 and a terminal emulation program to configure the NetAXS panel for normal operation A 2 2 Communication Settings Baud Rate 115200 Data Bits 8 Parity None Stop Bits 1 Flow Control None A 2 3 Emulation Settings Echo typed characters locally YES Line Delay 500 milliseconds A 2 4 Verifying Communications 1 Press the spacebar 2 Press the carriage return lt CR gt S apppear for every online panel and indicates proper communication between the terminal and panel 52 www honeywell com NetAXS Standalone Operation Standalone Commands A 3 Standalone Commands Use the following commands in the order they are listed to configure the NetAXSTM panel 1 T command Sets the panel s Time D command Sets the panel s Date 2 3 L command Creates Time zones for use by the cards 4 C command Adds or Deletes cards from the panel 5 W command Program each input for either NO NC and Supervised or NON Supervised operation 6 P command Sets interlocks betwee
12. Ground EG Only Earth Ground EG one side of cable one side of cable EG EG EG EG It is recommended to Earth Ground EG each NetAXS enclosure individually NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 29 NetAXS NX4S1 Installation System Configuration 5 4 RS 232 Connection This connection supports one NetAXS Access Controller panel for each COM port It has been reviewed by UL However because UL has reviewed the NetAXS panel only as a standalone system the computer terminal and NetAXS gateway panel appear in this section only to illustrate the installation and programming of the NetAXS M panel Figure 20 RS 232 Connection CBL50 RS 232 50 Ft Max Terminal CBL50 RS 232 DIP Switch Settings 50 Ft Max S1 S5 Panel Address S6 OFF NetAXS NetAXS Panel Panel A SSN EG It is recommended to Earth Ground EG EG each NetAXS enclosure individually CBL50 RS 232 RS 232 RJ 45 DB9 Reguest To Send RTS 8 lt 2 Signal Ground GND 5 lt 2 J 3 Receive Data RXD 2 lt gt 4 Transmit Data TXD 3 lt gt 5 Clear To Send CTS 7 lt gt 7 9 Pin COM 1 or COM 2 to RJ 45 on NetAXS Panel 30 www honeywell com NetAXS NX4S1 Installation System Configuration 5 5 Ethernet Connection This connection supports a maximum of 255 IP connections per server It has not been reviewed by UL Figure 21 Ethernet Connect
13. Modem shield 120 ohm 23 pf HAS part no NCP2441 TN DTE H DIP Switch Settings DIP Switch Settings S2 Loopback S1 S5 Panel Address S1 S5 Panel Address ON i S6 OFF S6 OFF J36 CLOSED J36 OPEN J37 CLOSED J37 OPEN 5279 9 sq Feet I I L___ lt gt 0 I lt S2 Loopback NetAXS NetAXS W L J K I EG Panel EG Panel Eg i HE I l I SSCS Jersom aa a I l CONTROL I ODN Only Earth Ground EG one side of cable I an Jumper EG EG l J It is recommended to Earth Ground EG each I NetAXS enclosure individually I SHM B ASYNCH lt m J1 RS 232 Connector I I I l RS232 Cable MODEM DIP Switch Settings PC DTE DCE S1 ON RS 232 50 Ft Max DB 9 Straight Null Zon Male 9 Pin lt gt Male 25 Pin 2TX 2 TX 2 RX 3RX gt 3 RX or 3 TX S4 ON 5 Comm lt 7 GND 7 GND S5 ON S6 OFF Ack Nak Enable S7 ON Refer to 485 PCI NetAXS Panel S8 OFF 19 200 Baud Rate Connection Detail diagram NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 33 NetAXS NX4S1 Installation System Configuration 5 8 RS 485 Short Haul Modem Connection via NetAXS Thirty one NetA XSTM Access Controller panels for each drop line It has not been reviewed by UL Figure 24 RS 485 Short Haul Modem Connection via NetAXSTM RS232 Cable MODEM PC DTE DCE DB
14. NetAXS enclosure RS485 Individually Red White Black Green RS 485 COM DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37 OPEN RS 485 Drain Wire to earth cl RS 485 4000 Ft Max FC485 RS 485 Fiber Converter D RS 485 Comm Rs 485 Positive CO RS 485 Negative Fiber RXD Fiber TXD FC485 RS 485 Fiber Converter RXD PWR TXD Fiber RXD Fiber TXD RS 485 Cable NetAXS Panels TB7 1 RS485 TB7 2 RS485 TB7 3 RS485 COM 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN 38 www honeywell com NetAXS NX4S1 Installation System Configuration 5 13 Fiber Converter to RS 485 Connection via NetAXS TM This connection supports thirty one NetAXS Access Controller panels for each drop line It has not been reviewed by UL Figure 29 Fiber Converter to RS 485 Connection via NetAaXS RS 485 4000 Ft Max COM Port RS 232 50 Ft Max Terminal NetAXS Panel FC485 RS 485 Fiber Converter RXD PWR DIF Switch Settings S1 S5 Farel Adcress TXD YDDYN P S6 CN FC485 NetAXS Panel J36 CLCSED RS 485 Fiber Converter RS 485 Comm D lt TB1 3 RS485 COM EG J37 CLCSED j RS 485 Positive 4 TB1 1 RS485 RS 485 Negative PL TB1 2 RS485 NetAXS P l e ane RS 485 Drain Wire Floating s
15. PROFITS LOSS OF USE INCIDENTAL CONSEOUENTIAL OR SPECIAL DAMAGES TO ANY PERSON RESULTING FROM THE USE OF HONEYWELL PRODUCTS 1 4 Federal Communications Commission This eguipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This eguipment generates uses and can radiate radio freguency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this eguipment does cause harmful interference to radio or television reception which can be determined by turning the eguipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or re locate the receiving antenna Increase the separation between the eguipment and receiver Connect the eguipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The user shall not make any changes or modifications to the eguipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the egui
16. bus is wired into the NetAXS TB10 terminal block The downstream bus has a fixed baud rate and communicates to the MIRO modules using a polling technigue Each MIRO module needs to have a unigue address for proper communication Each one also has some configuration jumpers that need to be positioned correctly The following table lists the DIP switch and jumper settings for the MIRO 32 0 and 2 16 modules Table 4 MIRO 32 0 DIP Switch and Jumper Settings Module Setting Value MIRO 32 0 DIP switches Address switches 1 6 I or 2 Baud rate switches 7 and 8 7 OFF 8 ON OP Mode switches 9 and 10 9 OFF 10 OFF NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 23 NetAXS NX4S1 Installation Installation Table 4 MIRO 32 0 DIP Switch and Jumper Settings continued Module Setting Value Jumper settings JP1 CLOSED if the module is the last module on the downstream bus OPEN if the module is not the last module on the downstream bus JP2 any setting JP3 any setting JP4 NORMAL Positions I and 2 MIRO 2 16 DIP switches Address switches 1 6 3 through 6 Baud rate switches 7 and 8 7 OFF 87 ON OP Mode switches 9 and 10 9 OFF 10 OFF Jumper settings JP1 CLOSED positions 2 and 3 if the module is the last module on the downstream bus OPEN positions 1 and 2 if the module is not the last
17. module on the downstream bus JP2 NORMAL positions 1 and 2 Note If a MIRO 32 0 is not required in a system start addressing the 2 16 modules at DIP switch 3 Ifa MIRO 32 0 is configured with an address other than 1 or 2 the NetA XSTM panel will not communicate with it Likewise if a MIRO 2 16 is configured with an address other than 3 through 6 the NetAXSTM panel will not communicate with it E The NetAXSTM board is not intended to provide either module power or module output load power for downstream I O A separate 24VDC supply should be used to provide power to all downstream modules and output loads For some installations the noise immunity improves if the NetAXS common is connected to the 24 VDC Return wiring for the downstream modules This connection is not needed for most installations 24 www honeywell com NetAXS NX4S1 Installation Installation The following figure shows the default downstream I O system configuration with communication and power wiring This configuration has not been reviewed by UL Figure 15 Default Downstream I O Configuration with Wiring RS 485 A RS 485 A asas JB32 RS 485 B 32 0 JP1 OFF ADDRESS 1 RS 485 A TB3 2 RS 485 B TB3 3 ai Tas __ aa mwyn JP1 OFF 4VDC R TB34 ADDRESS 2 TB5 2 I 2116 24VDC VDCR JP1 OFF ADDRESS 3 RS 485 A RS 485 B 2116 szavoc JP1 OFF ADDRESS 4 RS 485 A Tel
18. panel has the following four additional generic form C relay outputs that can be programmed using the P command Relay output Controls 5 Output 5 6 Output 6 7 Output 7 8 Output 8 62 www honeywell com Honeywell Access Systems 135 W Forest Hill Avenue Oak Creek WI 53154 United States 800 323 4576 414 766 1798 Fax www honeywellaccess com Specifications subject to change without notice O Honeywell All rights reserved Document 800 00008 Revision A Honeywell
19. positive red Power Supply to Battery cable to the positive red battery terminal NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 9 NetAXS NX4S1 Installation Installation 14 Attach the negative black Power Supply to Battery cable to the negative black battery terminal 15 For panels using the Ethernet connection the cable clamp HAS part number 3 000342 must be used for the panel to pass the FCC Part 15 Class B requirements Snap the clamp around any portion of the Ethernet cable that is inside of the enclosure 4 1 Cabinet Mounting The following five figures show the back top bottom right and left views of the NetAXS panel cabinet Each view includes the dimensions and knockout placement that you will need to mount the cabinet All dimensions are given in inches See Table 1 on page 14 for dimensions of the conduit entries into the cabinet Figure 2 NetAXS NX4S1 Panel Cabinet Front View uu G Z9 Z 6 tl co l uu 9z 181 8 l Z 31 32 25 mm a 1 4 6 25 mm lt Q 2 30 32 75 mm a 3 8 9 375 mm diameter 3holes 1 23 32 43 75 mm diameter knockout 12 1 16 306 25 mm 15 3 4 400 mm 1 4 6 25 mm 17 23 32 450 mm o uu 6 81 b e GL v ZE EZ L uu SZ 181 8 1 uu G 81 91 6 ZL uu G Ep b El 09 29 Z lL YL 10 www hon
20. switch setting to be recognized DIP switch positions 1 5 are used to select the panel s address on the network Refer to Table 3 for DIP switch setting information Connectors J36 and J37 are provided for supplying biasing and end of line termination for the RS 485 network The board ships with all jumpers open For a Multidrop RS 485 line you must close both J36 and J37 terminated and biased at the two end point panels At all other panels leave J36 and J37 open Both jumpers on a given panel must set the same Note that biasing and termination on both ends are present Use the jumpers on both ends of the RS 485 network Note Ifan RS 485 network has a NetAXSTM Gateway panel no N1000 II N1000 III or N1000 IV are allowed on the same network If they are added to a network with a NetA XSTM Gateway panel they will not be able to communicate with the host computer Figure 10 RS 485 Configuration via N 485 PCI 2 or PCI 3 N 485 PCI 2 3 Terminal RS 485 Multidrop Line Reader 1 NetAXS Panel Reader 4 A combination of N1000 III N1000 IV NS2 and NewAXS panels supporting a total of 31 panels per multi drop line 18 www honeywell com NetAXS NX4S1 Installation Installation Figure 11 RS 485 Configuration via NetAXSTM Gateway Reader 1 NetAXS Gateway e Reader 4 ED Terminal RS 485 Multidrop Line Reader 1 O
21. 1000 III IV specifications and that communicate with each other and with a variety of input and output devices over the RS 232 and RS 485 network protocols See System Configuration on page 26 to view illustrations of the supported NetA XSTM system configurations A NetAXS access control system is configured and maintained via either the host system or a web server using RS 232 RS 485 or Ethernet network protocols This document describes how to install and configure the NX4L1 access control unit NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 5 NetAXS NX4S1 Installation Panel Components and Descriptions 3 0 Panel Components and Descriptions The NX4S1 access control unit consists of a NetAXSTM panel control board and battery The components are enclosed in a pre wired cabinet The 16 5 VAC power supply Basler Electric Model BE156250CAA0004 M amp G Electronics Model MGT1650 or Honeywell Access Systems part number X 4 provides power for the panel control board which is a four reader panel providing access control for up to four doors The following figure shows the NX4S1 panel components Figure 1 NX4S1 Panel Components S M i Enclosure Grounding Studs NetAXS Access Control Panel Enclosure Tamper Switch E wasis 9 Enclosure Grounding Studs AC Power LED Battery mm 6 www honeywell com NetAXS NX4S1 Installation Panel Co
22. 12 14 2009 with a day of week being Monday 54 www honeywell com NetAXS Standalone Operation Standalone Commands A 3 3 L Time Zone Command E _L pn tz hi ml h2 m2_days lt CR gt Variables pn panel number 1 31 tz time zone number 1 255 hl start time zone hours 00 23 Military time ml start time zone minutes 00 59 h2 end time zone hours 00 23 Military time m2 end time zone minutes 00 59 days days of week valid values as listed below 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday 0 Holiday 1 8 Holiday 2 9 Holiday 3 Note 00 00 is the earliest time possible and 23 59 is the latest time possible A single time zone cannot be made to span mid night through the use of extended commands we can simulate this For more information please seek the guidance of technical support Example 1 This command would configure panel 5 to add a time zone entry to time zone number 10 ranging from 8AM to 5PM and would be valid during Monday Tuesday Wednesday Thursday and Friday Example 2 This command would configure panel 25 to add a time zone entry to time zone number 45 ranging from 4PM to 11 59PM and would be valid during Saturday Sunday Holiday 1 2 and 3 NetAXS Access Control Unit NX4L1 Installation Guide 7 901099 Revision A 55 NetAXS Standalone Operation Standalone Commands A 3 4 C Card Add Command
23. 8 RJ 45 Serial Port RJ 45 RS 232 DB9 Reguest to Send RTS Signal Ground TXD Receive Data RXD Transmit Data TXD Clear to Send CTS oan A O N 6 5 2 3 7 Figure 9 RS 232 Configuration 4 LJ Reader 1 NetAXS e Panel A a Reader 4 Terminal ne A Reader 1 Y NetAXS A Panel U Reader 4 One NetAXS panel per COM port Two COM ports possible NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 17 NetAXS NX4S1 Installation Installation 8 E RS 485 Communications The NetAXS panel can reside on an existing RS 485 drop line hosted by either a NetAXS panel configured as a Gateway or N 485 PCI 2 PCI 3 or N 485 HUB 2 see Figure 10 on page 18 Figure 11 on page 19 and Figure 23 on page 33 The interface allows the wiring of a Multidrop communication network of up to 4 000 feet 1200 m in length Only one host converter device per dropline is supported Note On a Multidrop line the Gateway panel and the PCI unit can have either end point or interior positions See Figure 18 on page 28 and Figure 19 on page 29 for illustrations DIP switch position 6 on the NetAXSTM panel selects whether the panel is a Gateway or Multidrop panel The switch in the OFF position configures the panel as a Multidrop panel ON configures a Gateway The panel must be power cycled for a new
24. 9 Straight Null RS 232 50 Ft Max 2TX 2 TX 2 RX 3RX 3 RX or 3 TX 5 Comm lt gt 7 GND 7 GND Terminal SHM B ASYNCH Short Haul Modem lt J1 RS 232 Connector RS 485 Cable s g NetAXS Panels TB7 1 RS485 DcE 9 ODN TB7 2 RS485 2a Jaz O lt Jumper TB7 3 RS485 COM 8 x gt lt lt ODIS 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN RTSIDTR CONTROL lt S2 Loopback DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN l Short Haul Modem RS232 Cable MODEM J37 CLOSED J37 OPEN 5279 9 Foot Lo lt S2 Loopback NetAXS NetAXS LY See RS 485 EG Panel EG Panel Cable note I l I I I RTSIDTR lU DD sssi I I CONTROL ODN Only Earth Ground EG one side of cable l os Jumper I ODIS EG EG T It is recommended to Earth Ground EG each I NetAXS enclosure individuall Y SHM B ASYNCH lt 41 RS 232 Connector I I I DIP Switch Settings 7 PC DTE DCE S1 S5 Panel Address RS 232 50 Ft Max DB 9 Straight Null S6 ON Male 9 Pin lt gt Male 25 Pin 2TX 2 TX 2 RX J36 CLOSED 3RX 3 RX or 3 TX J37 CLOSED 5 Comm
25. Honeywell NetAXS NX4S1 Access Control Unit Installation Guide May 15 2007 O 2007 Honeywell All rights reserved 800 00008 Revision A Copyright 2007 Honeywell All rights reserved All product and brand names are the service marks trademarks registered trademarks or registered service marks of their respective owners Printed in the United States of America Honeywell reserves the right to change any information in this document at any time without prior notice Ordering Information Please contact your local Honeywell representative or visit us on the web at www honeywellaccess com for information about ordering Feedback Honeywell appreciates your comments about this manual Please visit us on the web at www honeywellaccess com to post your comments CONTENTS NetAXS NX4S1 Installation LOGNoticeegau t san Sam Y eee Gee maa eo do ate ind ee DO 1 1 1 Warningsand Cautions uy u y yw Y GWY FF 1 1 2 Product Liability Mutual Indemnification a 2 1 3 Limited Warrantys sn Sa A YF GAR 2 1 4 Federal Communications Commission n DN RHE ND DD Dn oo 3 1 5 Industry Canada se id GY aa ceda 3 1 6 Underwriters Laboratories Incorporated AH RR HR HY Ho 4 2 0 Introduction A NG EE FY RF a 5 21 Access Control OVervieW drig YY dida halved RE 5 2 2 NetA XSTM Access OVErVicW cccscccssecsscessces
26. Hr battery 22 1 pounds 10 kg 7 7 Environment Temperature 0C to 49C operating 55C to 85C storage e Humidity 5 to 85 RHNC NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 45 NetAXS NX4S1 Installation Hardware Specifications 7 8 Communications and Wiring Table 6 Communications and Wiring 7 9 Reader Wiring Communication Type Description M um Mann Distance Panels Feet Meters Direct to COM Port CBL50 RS 232 Cable 9 pin to RJ 45 1 50 15 N 485 PCI 2 RS 485 9 pin to CPU 31 4 000 1 220 Modems A N HN 31 5 280 4 000 1 610 1 220 SHM B ASYNC CBL50 YE Modems 1 5 280 50 1 610 15 M 56K N 485 HUB 2 Dial up Modem to RS 485 31 NA 4 000 NA 1 220 Fiber FC485 Fiber converter to RS 485 31 10 000 4 000 3 050 1 220 Table 7 Reader Wiring Cable Specifications Description AWG Maximum Distance Feet Meters Readers NC1861 BL 6 Conductor Shielded 18 500 153 Alarm Input NC1821 GR Twisted Pair Shielded 18 2 000 610 Relay Outputs NC1821 GR Twisted Pair Shielded 18 2 000 610 www honeywell com NetAXS NX4S1 Installation Hardware Specifications 7 10 NX4S1 Wiring Diagram Figure 33 NX4S1 Panel Wiring Diagram Tamper Switch Panel Tamper IN 14 RESERVED FOR FUTURE USE Common ACFAIL IN 13 Ethernet nv N
27. I 2 on page 26 RS 485 Connection via NetA XSTM on page 27 and RS 232 Connection on page 30 of this guide Because UL has reviewed the NetAXS panel only as a standalone system the computer terminal NetAXSTM gateway panel and N 485_PCI 2 adapter appear in these sections only to illustrate the installation and programming of the NetAXS panel UL has not evaluated the compatibility of downstream I O devices see Downstream I O on page 23 with the NetAXS panel 4 www honeywell com NetAXS NX4S1 Installation Introduction 2 0 Introduction 2 1 Access Control Overview An access control system protects and preserves an enterprise s resources by providing authentication authorization and administration services Authentication is a process that verifies a user s identity If the user is verified the system then either grants or denies access to specific areas and resources Administration includes the creation and modification of user accounts and access privileges An access control system consists of hardware and software usually configured in a network environment over a standard network protocol Access control units readers door strikes and video and other devices for example are configured to control and monitor the access to a company site 2 2 NetAXS Access Overview A NetAXS access control system consists of a host system and NetAXS access control units that meet existing N
28. K Dial up Modem RS 485 Connection via Hub Thirty one NetAXS Access Controller panels for each drop line It has not been reviewed by UL Figure 26 M 56K Dial up Modem RS 485 Connection via Hub NetAXS Panel M 56K FAX MODEM COM Port Straight Through Cable n O Analog Remote DIP Switch Settings Phone j Female 9 Pin Male 25 Pin 1 3 8 ON 2 4 5 6 7 OFF Line Terminal RX 2 gt 3 RX TX 3 2 TX Dedicated Comm 5 gt 7 Comm M 56K analog FAX MODEM phone N 485 HUB 2 RS 232 50 ft S recommended O o C Remote DIP Switch Settings 1 3 8 ON 2 4 5 6 7 OFF RS 485 4 000 ft 1 Refer to 485 I PCI 2 NetAXS l Panel a EN i O DIP Switch Settings etalrdiagram ON DIP Switch Settings DIP Switch Settings S2 ON S1 S5 Panel Address S1 S5 Panel Address i S3 ON S6 OFF S6 OFF 1 S4 ON J36 CLOSED J36 OPEN S5 ON J37 CLOSED J37 OPEN S6 ON Ack Nak ON 1 S7 ON S8 OFF 19 200 Baud Rate i Ne A I I 1 I I 1 1 I I EG See RS 485 Cable Note Only Earth Ground EG one side of cable EG EG It is recommended to Earth Ground EG each NetAXS enclosure Individually DB 9 DB 25 Connectors RS 485 Cable NetAXS Panels TB7 1 RS485 TB7 2 RS485 TB7 3 RS485 COM 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN
29. OPEN NetAXS Panel EG pl EGF _ PJ See RS 485 Cable Note Only Earth Ground EG one side of cable EG EG It is recommended to Earth Ground EG each NetAXS enclosure individually NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 27 NetAXS NX4S1 Installation System Configuration 5 3 RS 485 Connections with Multidrop Panels at Both Ends of the Cable You can connect Multidrop panels at both ends of an RS 485 cable via either a NetAXS panel or a PCI 2 device These configurations have not been reviewed by UL Figure 18 RS 485 Connection via NetAXS M with Multidrop Panels at Both Ends COM Port RS 485 4 000 Ft i 7 Ge a y Refer to Terminal NetAXS NetAXS NetAXS Lt Gateway Panel Connection Detail diagram RS 485 Cable NetAXS Panels TB7 1 RS485 TB7 2 RS485 TB7 3 RS485 COM DIP Switch Settings S1 S5 Panel Address S6 ON See RS 485 J36 OPEN Cable Note J37 OPEN 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J37 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37 OPEN DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J3 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J3 OPEN NetAXS Panel NetAXS
30. Panel I EG I 1 1 L lt lt m d Only Earth Ground EG Only Earth Ground EG one side of cable one side of cable EG EG EG It is recommended to Earth Ground EG each NetAXS enclosure individual 28 www honeywell com NetAXS NX4S1 Installation System Configuration Figure 19 RS 485 Connection via PCI 2 with Multidrop Panels at Both Ends COM Port RS 232 50 Ft Max RS 485 4 000 Ft N 485 PCI 2 Refer to N 485 PCI 2 NetAXS 000 O lt x Access Controller Panel Connection Detail diagram Terminal I I I I I I I I I I DIP Switch Settings I RS 485 Cable I ST ON I RS485 NetAXS Panels I S2 ON I Red TB7 1 RS485 I S3 ON i Black TB7 2 RS485 I S4 ON RS 485 COM TB7 3 RS485 COM I S5 ON I I S6 ON Ack Nak Enable I 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with I S ON I shield 120 ohm 23 pf HAS part no NCP2441 TN I 58 OFF 19 200 Baud Rate pee R5485 1 I Cable Note I I I I I I I I I I I DIP Switch Settings DIP Switch Settings DIP Switch Settings DIP Switch Settings I S1 S5 Panel Address 51 55 Panel Address 51 55 Panel Address 51 55 Panel Address y S6 OFF S6 OFF S6 OFF 56 OFF I J36 CLOSED J36 OPEN i J36 CLOSED J36 OPEN I J37 CLOSED J37 OPEN i J37 CLOSED J37 OPEN I f I I I i I I I I I i I I NetAXS I NetAXS I Panel Panel I EG I 1 EG mn I LL PPP Only Earth
31. Perform the following maintenance on the NetAXS enclosure e Change the CASIL CA1270 lead acid battery Honeywell Access Systems part number 3 000066 every two to two and a half years Caution Do not connect an uncharged battery to the panel Oil the lock once per year 9 0 Troubleshooting Table 8 Troubleshooting Problems and Solutions Problem The panel powers up but it does not respond to any communication cards reads or input activation Solution Ensure that the Address DIP switches are set to a value other than zero Turn off the power including battery change the settings and re apply the power No Only a panel set to be a Gateway DIP switch 6 ON will have communications communications on the Ethernet port If you need to use that port to exist with the access the panel turn off the power including the battery change the Ethernet port switch setting and reapply the power Note that if the panel is normally not a Gateway on a Multidrop communication bus then the Host RS 485 connection TB7 should also be disconnected while DIP switch 6 is ON After completion of the Ethernet session turn off the power including the battery change the switch setting re connect the Host RS 485 terminal block and re apply the power The IP addressis If you are connecting directly to a computer instead of going through a incorrectly set to verify the value router or hub use a cross over E
32. RLU1 N 485 PCI 2 mee Refer to wear i NetAXS Panel Connection Detail diagram DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J37 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37 OPEN NetAxs Panel See RS 485 Cable note It is recommended to Earth Ground EG each NetAXS enclosure individually Only Earth Ground EG one side of cable EG 32 www honeywell com NetAXS NX4S1 Installation System Configuration 5 7 RS 485 Short Haul Modem Connection via PCI 2 This connection supports thirty one NetAXS Access Controller panels for each drop line It has not been reviewed by UL Note that PCI 2 units can also be wired anywhere along the drop line See Figure 18 on page 28 and Figure 19 on page 29 Figure 23 RS 485 Short Haul Modem Connection via PCI 2 RS232 Cable MODEM PC DTE DCE DB 9 Straight Null RS 232 50 Ft Max 2TX 2 TX 2 RX 3RX 3 RX or 3 TX 5 Comm lt 7 GND 7 GND Terminal SHM B ASYNCH Short Haul Modem lt J1 RS 232 Connector RS 485 Cable J Qa y NetAXS Panels TB7 1 RS485 pcE ODN TB7 2 RS485 2 222 O lt Jumper TB7 3 RS485 COM 6 x gt lt lt __ ODIS RTSIDTR CONTROL 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with Short Haul
33. Reader 1 Reader 1 NetAXS Reader Reader 2 A combination of NetAXS and NS2 panels supporting a total of 31 panels per multi drop line NetAXS Reader 4 OI Ethernet TCP IP Communications Figure 12 Ethernet TCP IP Configuration Network Interface Card Inside PC Ethernet Up to 255 TCP IP Connections per System Ethernet 10 100 Terminal Reader 1 Reader 4 O NetAXS Gateway Cc RS 485 Multidrop Line Reader 1 Reader 4 J Reader 1 Reader 1 NetAXS Reader 4 Reader 2 A combination of NetAXS and NS2 panels supporting a total of 31 panels per multi drop line NetAXS Each NetAXSTM panel has a port for an Ethernet TCP IP interface see Figure 12 Ethernet TCP IP Configuration The Ethernet TCP IP interface provides 10 100 Mbit Ethernet support for each panel Up to 31 panels can be configured on each TCP IP connection NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 19 NetAXS NX4S1 Installation Installation Figure 13 on page 20 shows the location of the panel s unique MAC ID Figure 13 Ethernet MAC Address Location Label with Ethernet MAC Address 20 www honeywell com NetAXS NX4S1 Installation Installation 4 6 DIP Switch Settings Figure 14 on page 21 locates the N
34. S part no NCP2441 TN NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 37 NetAXS NX4S1 Installation System Configuration 5 12 Fiber Converter to RS 485 Connection via PCI 2 This connection supports thirty one NetAXS Access Controller panels for each drop line It has not been reviewed by UL Note that PCI 2 units can also be wired anywhere along the drop line See Figure 18 on page 28 and Figure 19 on page 29 Figure 28 Fiber Converter to RS 485 Connection via PCI 2 Refer to N 485 PCI 2 NetAXS Access Controller Panel Connection Detail diagram RS 232 50 Ft Max Terminal FC485 RS 485 Fiber Converter DIP Switch Settings RXD S1 ON BWR 52 ON TXD A oi S3 ON S4 ON RS 485 Comm P 4 S5 ON RS 485 Positive CD S6 ON RS 485 Negative S7 or S8 OFF 19 200 Bauq Rate Fiber TXD ls DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J37 CLOSED Fiber Cable 10 000 Ft Max NetAXS Panel 71 TB1 3 R8485 CON 7 A TB1 1 RS485 a TB1 2 RS485 Fiber Cable 10 000 Ft Max FC485 RS 485 Fiber Converter RXD PWR TXD RS 485 Drain not connected here connected at panel side RS 485 Drain Only Earth Ground EG one side of cable Fiber TXD a EG It is recommended to Earth Ground EG each
35. Switch Settings S1 S5 Panel Address S6 ON J36 CLOSED J37 CLOSED DO NOT CONNECT SHIELD Ground only one side of cable shield NetAXS Panel NetAXS TB7 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf NCI part no NCP2441 TN NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 41 NetAXS NX4S1 Installation NetAXS M Startup 6 0 NetAXS Startup 6 1 LED Operation When the panel wiring is complete turn on the power It might take a few minutes for the panel to complete the power up sequence When the board does initialize verify that the appropriate LEDs identified in the following figure are in accord with the descriptions in Table 5 on page 43 Figure 32 System Relay and Power LEDs O JO e RDR 3 Ethernet Status Host RS232 and OK POR LEDs Downstream LEDs Run LED gt DDOI 000000000 0000000000000 RS485 LED RDR 1 OJ RDR 2 Relay Status LEDs 5 Relay Status O LEDs 5 O o Power O O O 42 www honeywell com NetAXS NX4S1 Installation NetAXS M Startup The following table indicates the status associated with each LED Table 5 LED Status LED PWR RUN H485 H232 DS COM LINK RLY RDR GREEN Power Blink Multi RS232 Down 100Mbit Link Relay Flash
36. X4S1 DIP switch panel and the J36 and J37 termination and biasing jumpers Figure 14 DIP Switch and Jumper Locations WW J37 Ll fuse JH DIP Hs Switches NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 21 NetAXS NX4S1 Installation Installation Use the following DIP switch configurations to set the panel address Table 3 DIP Switch Settings S1 S2 S3 S4 S5 S6 Selection on off off off off Address 1 default off on off off off Address 2 on on off off off Address 3 off off on off off Address 4 on off on off off Address 5 off on on off off Address 6 on on on off off Address 7 off off off on off Address 8 on off off on off Address 9 off on off on off Address 10 on on off on off Address 11 off off on on off Address 12 on off on on off Address 13 off on on on off Address 14 on on on on off Address 15 off off off off on Address 16 on off off off on Address 17 off on off off on Address 18 on on off off on Address 19 off off on off on Address 20 on off on off on Address 21 off on on off on Address 22 on on on off on Address 23 off off off on on Address 24 on off off on on Address 25 off on off on on Address 26 on on off on on Address 27 off off on on on Address 28 on off on on on Address 29 off on on on on Address 30 on on on on on Address 31 off NetA XSTM Mu
37. ackup battery Memory Protection The NetAXSTM panel continuously saves database and event information in non volatile FLASH memory This activity prevents the panel from losing data when power is lost Reader and AUX Power Reader power is supplied within the range of 11 2 VDC and 12 4 VDC with a maximum current of 600 mA AUX power is supplied within the range of 10 5 VDC and 12 4 VDC with a maximum current of 500mA The current can be distributed throughout the Reader Power or AUX Power in any configuration as long as the maximum draw is less than 600 mA Reader 1 Reader 2 Reader 3 Reader 4 AUX Power lt 600 mA i Caution AUX Power must not be used to power locks For NetAXSTM maximum current draw refer to Hardware Specifications page 44 NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 7 NetAXS NX4S1 Installation Panel Components and Descriptions 3 2 Power Supply N The NetAXS panel is capable of operating on AC or DC input power UL has not reviewed the use of a DC power supply with the NX4S1 panel The AC input must be supplied at 16 5 VAC utilizing one of the following UL listed 50 VA Class 2 transformers Basler Electric Model BE156250CA A0004 M amp G Electronics Model MGT1650 Honeywell Access Systems part number X 4 Use a two wire 18 AWG shielded cable to run the AC power from the wall transformer to the enclosure The AC voltage is non polarized and connect
38. at OK normal drop Receive stream OK Active read Steady Receive Data Receive malfunc Data Data tion RED N A N A Trans m Trans m Trans m N A N A N A N A itData itData it Data AMBER N A N A TX amp TX amp TX amp N A TX amp N A N A RX RX RX RX Data Data Data Data OFF Power Mal No No No 10Mbit No Relay Normal Off function Com Com Com Link Off Note The Ethernet COM status LED will be green even if no cable is attached NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 43 NetAXS NX4S1 Installation Hardware Specifications 7 0 Hardware Specifications 7 1 Relay Contacts Four Form C SPDT relays 10 A 28 VDC resistive load 5 A 28 VDC inductive load 7 2 Reader Interface Reader Output Voltage ranges from 11 2 VDC to 12 4 VDC The maximum Reader Output Current is 600 mA Reader LED Output Open collector driver capable of sinking up to 8 mA Reader Tamper Supervised or non supervised input Reader Data Input TTL compatible inputs Reader Buzzer Output Open collector driver capable of sinking 8 mA at 15 VDC 7 3 NX4S1 Wire Requirements Power One twisted pair shielded 18 AWG RS 485 24 AWG 4 000 ft 1 200 m max twisted pairs with shield 120 ohm 23 pf HAS part number NC2441 TN RS 232 Use cable supplied with installation kit HAS part number CBL50 Maximum distance per COM port is 50
39. e 30 N 485 PCI Z NetAXS M Access Controller Panel Connection Detail 485 Interface Connection Types DIP Switch Settings S1 ON RS 485 NetAXS Panel S2 ON N 485 PCl2 lt COM Port S3 ON N 485 HUB2 gt M 56K Modem a N 485 PCl 2L gt LANSRL100 or LANSRLU1 5 S6 ON S7 ON S8 OFF A 1 2 To Serial Connection See 485 interface connection note Ground Shield DO NOT CONNECT or GROUND SHIELD N 485 PCI 2 oeo NetAXS TB7 NetAXS TB7 DIP Switch Settings DIP Switch Settings S1 S5 Panel Address S1 S5 Panel Address S6 OFF S6 OFF J36 CLOSED J36 OPEN J37 CLOSED J37 OPEN Ground only one side of cable shield 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN 40 www honeywell com NetAXS NX4S1 Installation System Configuration 5 15 NetAXS NetAXS Access Controller Panel Connection Detail Figure 31 NetAXS NetAXS Access Controller Panel Connection Detail Ground Shield DO NOT CONNECT or GROUND SHIELD To Serial Connection NetAXS TB7 NetAXS TB7 DIP Switch Settings S1 S5 Panel Address S6 OFF J36 CLOSED J37 CLOSED DIP Switch Settings S1 S5 Panel Address S6 OFF J36 OPEN J37 OPEN DIP
40. ececeseceseeesecaeceseeeeeeseecseeceeeeeseeeenees 52 A 2 3 Emulation Settings csi i dd YNI EGG FEE dd ON I DY GYD aha aspas 52 A 2 4 Verifying Communications YY noo LY ERYN TREFN DYNN NF DD EF nN 52 A 3 Standalone Commands a a ica 53 ALT Time Command nu enwer dud RYW sua FT aa ia A Cy 53 A 3 2 D Date Command i ii Dn 54 A 3 3 L Time Zone Command cnn nonn ron nn conan nr rn ron NHY DYDD DDAN 55 A 3 4 C Card Add Command docooocnocnonnnonnconocononononancon ccoo a rn YAR usul pisya sa asnaq 56 A 39 01 Card Delete Comm zn na n tia FYN suasana a 56 A 3 6 W Input Command u l D n q HYAY Can 57 A 3 7 P Interlock Command ii GYR DR DANDI hassan aga 57 A 3 8 Flow Control Disable Enableu u a n A IR Thus Sua 58 Ac4 NetAXSTM Panel Defaults 2 in A GW Wd FU Y Y YS 59 AAT Reader POrts oa s YG YY Y WG DF GYG ees 59 AAD Reader LED Outputs isis ue Ga a 59 A4 3 Reader Tamper puts inii y M dc dedi FFF DD DANO 60 A44 Door EgressinptltSs ua u nanan n unu YNI q a maq YY 60 AAS Doors tats Inputs u ee YD ydd QS bid ia 61 A 4 6 ACFAIL and Panel Tamper Inputs as 61 A 4 7 Additional Generic OWtpufSu ne u S a NEL EF ND ND DD Fon 62 NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A vi www honeywell com LIST OF FIGURES Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 F
41. eesseeesceeseceseeeeesecesesecsaecsaeceecseeeessecseeensenneenaes 5 3 0 Panel Components and Descriptions nnd r LL LLL ILALL LILI L FFY FYH YH RF D Hn nn nn 6 3 1 NetA XSTM Access Control Unitt ns rnsssssssssssssssssa 7 Real Time Clock Protect om irrita il dada cds ise T Memory Protection eru Sader e Yd a ON GY di A yi 7 Readerand AUX Power Mc cu i Y GW Y FfF ines 7 3 2 Power Supply Tasa 8 3 3 Battery y as Sua W a ua thua C IAEE DW tuaku taal 8 3 2 EnclosilTeu a n T PE ssn dade Sasu dias 8 329i SUPPTESSOTS Im sn n m m u NN Y Nu I 8 A un nanan aa TO 9 4 1 Cabinet Montini a n R D S CYW aaa Y FF qip sia 10 4 2 Reader WITING on inene nue 65250 unun Y Y AH dd rg di 14 4 3 Supervised Input Wiring staer u wadd i WEA o 14 4 4 NX4S1 Control Output Wiring a NND Y DN Ynn Fon 16 4 5 CommunicatIioBS L u n ccoo LS u Sq il DDYDD YDD DDU DD ND rca 16 RS 232 Communications u iu ge FT SC GYRFF iia 16 RS 485 Communications n HYN DY YND YND DDN FD NF nn N 18 Ethernet TCP IP Communications ns nann rana r rancia 19 46 DIP ONO 21 AT Jumper Settings u a cess a a e au aE eae da FON aan FAU 23 4 8 Downstream VO ic 23 NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 5 0 System Configuration a cono rn nnn rca
42. er earth ground Remove each terminal plug one at a time to wire the properly labeled cables See the wiring diagram Figure 33 on page 47 Leave enough shield drain length to secure to the grounding stud Also maintain a distance of at least 25 inches between the non power limited wiring battery backup charger wiring and all other wiring which is power limited Class 2 wiring Caution Do not plug in the wall transformer at this time Connect the shield and the green earth ground to the enclosure s grounding studs see Figure 1 on page 6 for the location of the enclosure s grounding studs Set DIP switch settings for the panel address Table 3 on page 22 and set J36 and J37 for communication termination and biasing see System Configuration on page 26 and Jumper Settings on page 23 Check all wiring at this time Caution Improper wiring can cause damage to the NetAXS panel at power up resulting in a loss of warranty 10 Power up the panel The power up seguence may take up to two minutes after which the RUN LED blinks green The RUN LED is located near Terminal Block TB 8 After the power up seguence check the LEDs to be sure the panel has powered up properly see LED Operation on page 42 11 Configure the panel by following the instructions in the NetAXS M Access Control Unit User s Guide 12 If you are using a battery backup function place the 7 A Hr battery in the enclosure 13 Attach the
43. eywell com NetAXS NX4S1 Installation Installation Figure 3 NetAXS NX4S1 Panel Cabinet Top View E Lo N S aN co 2 m Back 13 9 32 337 5 mm 14 9 32 362 5 mm 0 3 4 18 75 mm o 1 11 32 34 375 mm 14 16 21 875 mm diameter knockout 1 1 4 31 875 mm diameter knockout 4 7 32 107 5 mm Figure 4 NetAXS NX4S1 Panel Cabinet Bottom View All Knockouts punched through for easy removal without damage to cabinet 1 3 32 28 125 mm diameter knockout _ 14 16 21 875 mm diameter knockout NAON 1 ee NY 3 4 18 75 mm 0 1 16 32 38 275 mm 14 9 32 362 5 mm g E LO co 8 Back N co co co NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 11 NetAXS NX4S1 Installation Installation Figure 5 NetAXS Panel Cabinet Left View 4 11 32 110 mm Back 7 8 21 875 mm diameter knockout 1 15 32 37 5 mm po 3 4 18 75 mm 12 www honeywell com NetAXS NX4S1 Installation Installation Figure 6 NetAXS NX4S1Panel Cabinet Right View 411 32 110 mm Back 7 8 21 875 mm diameter knockout ww G 01 ZE 7 ww 6 81 NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 13 NetAXS NX4S1 Installation Installation 4 2 Reader Wiring Each reader port suppo
44. ft Supervised Inputs One twisted pair per input shielded 30 ohms maximum Outputs As reguired by load Readers 7 conductors 18 AWG shielded 500 ft 150 m max 7 4 Maximum Output Loading Notes E Maximum current for any of the four reader outputs is 600 mA Maximum current for each of the two auxiliary outputs on the NetAXS panel is 500 mA Maximum battery charge current for the single battery is 350 mA Maximum combined current of the four reader outputs and the two auxiliary outputs is 600 mA Maximum combined current of the two auxiliary outputs if used without the four reader outputs is 500 mA Each of the eight relay output contacts on the panel is rated for either 10 A at 28 VDC resistive or 5 A at 28 VDC inductive However they are powered from a separate power supply A UL listed system s power supply must also be UL listed for this application 44 www honeywell com NetAXS NX4S1 Installation Hardware Specifications 7 5 Common Connections Common connections are all connected internally They are not connected to the panel chassis 7 6 Mechanical Panel Dimensions Width 8 inches 203 2 mm Length 9 75 inches 247 65 mm Height 1 5 inches 38 1 mm Panel Weight 1 1 pounds 0 5 kg Enclosure Dimension Width 14 5 inches 368 3 mm Length 18 0 inches 457 2 mm Height 4 4 inches 111 8 mm Enclosure Weight including 7 A
45. hese wires with communication reader or supervised input wiring To minimize premature contract failure and increase system reliability a contact protection circuit HAS part number S 4 is highly recommended Locate the protection circuit as close as possible to the load 4 5 Communications N E Caution Do not route communication wires with power or locking devices Note Because UL has reviewed the NetA XSTM panel only as a standalone system the computer terminal NetAXS TM gateway panel and N 485_PCI 2 adapter appear in this section s figures only to illustrate the installation and programming of the NetAXSTM panel RS 232 Communications The NetAXS panel communicates with a PC through a 50 foot RS 232 cable HAS part number CBL50 Connect the RJ45 end of the cable to the jack on the NetAXSTM panel The cable is used to provide communication to a single panel A second cable can be used with another NetAXSTM control panel connected to a second COM communication port which would enable eight readers to be used see Figure 9 RS 232 Configuration A USB converter is also available that will provide RS 232 communications 16 www honeywell com NetAXS NX4S1 Installation Installation Figure 8 on page 17 illustrates the connections for an RS 232 DB9 9 pin connector to the panel s RJ 45 serial port Replacement cables can be obtained by contacting your Honeywell Access System Representative Figure
46. ical Support 10 1 Normal Support Hours Monday through Friday 7 00 a m to 7 00 p m Central Standard Time CST except company holidays 800 323 4576 10 2 Web For technical assistance please visit http www honeywellaccess com NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 49 NetAXS NX4S1 Installation Technical Support 50 www honeywell com NetAXS M Standalone Operation A A 1 Basic Standalone Operations A 1 1 Card Read Door Lock Operation 1 Presenta card to a reader 2 The reader sends the card number to a reader input on the panel 3 The panel searches its database and Ifitisa valid card then energize the door relay associated with the particular reader input The card is valid when it is in the card database on the panel and the current time and date conforms to the time zone associated with the card If it is not a valid card the door relay remains locked A 1 2 Door Egress Door Lock Door Status Operation 1 Activate the door egress input 2 The panel energizes the door relay associated with the particular door egress input for a default time of 10 seconds 3 If the door status goes from close to open to close again during the 10 second door open period the door relay will be immediately de energized NetAXS Access Control Unit NX4L1 Installation Guide 7 901099 Revision A 51 NetAXS Standalone Operation Standalone Settings A
47. igure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Figure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Figure 33 NX4S1 Panel Components ci n a NetAXSTM NX4S1 Panel Cabinet Front View NetAXS NX4S1 Panel Cabinet Top View NetA XSTM NX4S1 Panel Cabinet Bottom View NetA XSTM Panel Cabinet Left View a NetAXS NX4S1Panel Cabinet Right View Typical Supervised Input Wiring Diagram RJ 45 Serial Port ua Y Gy y GY NG Ro 252 Config rati n ee a aaa a un do uma RS 485 Configuration via N 485 PCI 2 or PCI 3 RS 485 Configuration via NetAXSTM Gateway Ethernet TCP IP Configuration ddd UO Ethernet MAC Address Location LIII LLY LL Finn DIP Switch and Jumper Locations Y YNA Default Downstream I O Configuration with Wiring RS 485 Connection via PCI 2
48. ion NIC 100BaseT CAT 5 328 Ft Max HUB SWITCH Terminal RS 485 Multidrop 100BaseT CAT 5 328 Ft Max Crossover Cable DIP Switch Settings S1 S5 Panel Address S6 ON Gateway 100BaseT CAT 5 328 Ft Max It is recommended to Earth Ground EG DIP Switch Settings S1 S5 Panel Address DIP Switch Settings S1 S5 Panel Address S6 OFF a S6 OFF each NetAXS I enclosure a individually o o NetAXS Panel EG EG EG EG NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 31 NetAXS NX4S1 Installation System Configuration 5 6 LANSRLU1 Connection This connection supports thirty one panels for each drop line and a maximum of 255 IP connections It has not been reviewed by UL Note that PCI 2 units can also be wired anywhere along the drop line See Figure 18 on page 28 and Figure 19 on page 29 Figure 22 LANSRLUI Connection HUB SWITCH S Terminal COLIC IE TE LTA le RS 485 Cable RS485 NetAXS Panels Red White TB7 1 RS485 100BaseT Black Green TB7 2 RS485 ae sss t TBr 2 R9498 COM t Max DIP Switch Settings S1 ON S2 ON S3 ON S4 ON S5 ON S6 ON Ack Nak ON S7 ON S8 OFF 19 200 Baud Rate 4 000 ft 1 200 m max 24 AWG 2 twisted pairs with shield 120 ohm 23 pf HAS part no NCP2441 TN LANS
49. length of the cable Remember that the distance from the panel to the door must be doubled to determine the total resistance NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 15 NetAXS NX4S1 Installation Installation A Caution The cable shield should be grounded only at the panel earth ground Grounding at both ends can cause ground loops which can be disruptive Caution The system has not been verified for compliance with UL1076 Burglar Alarm units and systems 4 4 NX4S1 Control Output Wiring A Relay 1 is defaulted for control of the Door 1 lock Relay 2 is defaulted for the control of the Door 2 lock Relay 3 is defaulted for the control of the Door 3 lock and Relay 4 is defaulted for the control of the Door 4 lock Relays 5 8 are used as auxiliary relays Refer to the NetAXS M Access Control Unit User s Guide for details on controlling the relay operations Each relay also has a green indicator LED which indicates the relay state If the relay is active the LED is illuminated Power for the door locks or auxiliary loads must be supplied from a separate external power supply A UL listed system s power supply must also be UL listed for this application Caution The cable used must be sized for the current load and should be shielded The cable shield should be grounded at the panel only Grounding at both ends can cause ground loops which can be disruptive Do not bundle t
50. ltidrop on NetA XSTM Gateway E Note Address 0 is not a valid setting for standard operations 22 www honeywell com NetAXS NX4S1 Installation Installation 4 7 Jumper Settings The NX4S1 panel control board includes jumpers 36 and 37 which set end of line termination and biasing for the Multidrop RS 485 line The board ships with all jumpers set to OFF For a Multidrop RS 485 line you must set both J36 and J37 to CLOSED terminated and biased at the two end point panels At all other panels leave J36 and J37 at OPEN Note that both jumpers on a given panel must either be OPEN or CLOSED 4 8 Downstream I O E Note UL has not evaluated the compatibility of downstream I O devices with the NetA XSTM panel In some applications the number of system inputs or outputs exceeds the number that is standard on the NetAXS panel The solution is to add a combination of MIRO 2 16 and MIRO 32 0 modules external to the NetA XSTM enclosure on a dedicated RS 485 Downstream Input Output I O bus A maximum of two MIRO 32 0 and a maximum of four MIRO 2 16 for a total of six MIRO modules can be added to the downstream bus A MIRO 32 0 module has 32 supervised four state inputs that are limited to 1 000 ohms resistance The MIRO 2 16 has two supervised inputs and 16 SPDT relay outputs each input is limited to 1 000 ohms resistance Refer to the individual installation manuals for I O wiring details The downstream I O
51. mmed as supervised normally open on panel 1 A 3 7 P Interlock Command P pn I O number I O number D E F N P _ D E F N P lt CR gt Parameters number for an input number the range is 1 96 for output 0 78 D De energize E Energize F Follow N No action P Pulse Example P 1 I 5 03 ED When Input 5 is triggered Output 3 energizes When Input 5 returns to its normal state Output 3 de energizes NetAXS Access Control Unit NX4L1 Installation Guide 7 901099 Revision A 57 NetAXS Standalone Operation Standalone Commands A 3 8 Flow Control Disable Enable Use this command only for a dropline panel using RS 232 in standalone mode _U panel name _ D E Parameters D Disable E Enable Example _U 30_D This disables the flow control on panel 30 and prevents the panel s buffers from filling After a hard re set of the panel the flow control is re enabled 58 www honeywell com NetAXS Standalone Operation NetAXS Panel Defaults A 4 NetAXS Panel Defaults A 4 1 Reader Ports The panel accepts a Wiegand serial data packet from the card reader If the card is in the database the associated relay is activated If the card is not in the database the relay state is unchanged The following are the default reader port to relay associations Reader Number 1 Controls Relay 1 Output 1 2 Relay 2 Output 2 3 Relay 3 Output 3 4 Relay 4 Outpu
52. mponents and Descriptions Note Maintain at least a 25 inch distance between the non power limited wiring battery backup charger wiring and all other wiring which is power limited Class 2 wiring 3 1 NetAXS Access Control Unit The NetAXS panel is a four reader board that controls up to four doors by providing up to 14 inputs and 8 outputs The NetAXSTM panel may be used as a stand alone panel with independent card and transaction storage or with a host software upgrade as a fully monitored online access control device The NetAXSTM panel also supports up to 30 downstream panels in a variety of network configurations See Communications page 16 for descriptions and illustrations Fourteen inputs are capable of four state supervision Normal Alarm Short and Open Eight inputs are used as door control with one input used for request to exit on each door and one input used for door status on each door Supervised inputs for Tamper External Power Fail and four Reader Tampers are supplied as well and they can be used as additional inputs when not required for their default purpose relay board can the common power supply be used for the NetAXSTM and locking i Caution The NetAXSTM board must not be used to power locks Only through the devices Real Time Clock Protection The panel RTC is backed up using a super capacitor The super capacitor will power the real time clock for one week in the absence of primary power or b
53. n input points and or output points 5 Note In all examples the underbar indicates a space character and lt CR gt indicates a carriage return A 3 1 T Time Command _T pn_hh mm lt CR gt Variables pn panel number 1 31 hh hours 0 23 Military time mm minutes 00 59 Example 1 _T 1_08 30 lt CR gt This command would set panel 1 to a time of 8 30 AM Example 2 _T 6_18 15 lt CR gt This command would set panel 6 to a time of 6 15 PM NetAXS Access Control Unit NX4L1 Installation Guide 7 901099 Revision A 53 NetAXS Standalone Operation Standalone Commands A 3 2 D Date Command E _D pn mm dd yyyy_ day lt CR gt Variables pn panel number 1 31 mm month number 1 12 dd day number 1 31 yyyy year number ex 2007 1999 etc day day of week 1 7 1 Monday 2 Tuesday 3 Wednesday 4 Thursday 5 Friday 6 Saturday 7 Sunday Note The day of week setting is a hold over from an old command The panel using the mm dd yyyy information will automatically configure panel to the correct day of the week regardless of the setting selected in day of week But the command still requires a value to be entered in its place of 1 7 Example 1 _D 1_01 09 2007_5 lt CR gt This command would set panel 1 to a date of 1 9 2007 and to Tuesday as the day of the week Example 2 _D 25 12 14 2009 7 lt CR gt This command would set panel 25 to a date of
54. nam TF uuu np Y FY ss dete FD eae du 44 FB NX4S1 Wire Reguirements e e nu u u aula aa aa 44 7 4 Maximum Output Loading s nasssnssssssssssssssssa 44 7 5 Common Connections annus 45 0 Mechanical Cu atan uq ua Gata um Mu mua a ada 45 yT Bmyironmentine en duu CM un nA NC na de Cu FY de quisu qn utk 45 7 8 Communications and Wirting HYLL ALYN corn nnnrrnnn corn connnn rana ND rra 46 TED Reader O meu ni GY DH GR YD GT yT 46 7 10 NX4S1 Wiring Diagram isinic aaa E ND Dn Fn dnn 47 OMA YA WR WU 48 9 0 Troubleshootin gui ui 2 viet a auqa FFY UD FD Atle ess NUW GB 48 10 0 Technical Support u A I GG anan 49 10 1 Normal Support Hours HYLY RLIY nnnnncnnronnnonnn corn DD DDN DD FD Ynn 49 10 2 WeD nue asqa aS aah Y da FN EE YN 49 iv www honeywell com NetAXS Standalone Operation A l Basic Standalone Operations c ccccecesssssssssssssesesesesssesesesesesssesesesesesssesesesenensaeseseseneneseseseneneaeaees 51 A 1 1 Card Read Door Lock Operation ns 51 A 1 2 Door Egress Door Lock Door Status Operation T 51 A 2 Standalone Settings A hh di dl 52 A 2 1 NetAXS Panel Hardware Settings aa 52 A 2 2 Communication Settings 0 0 0 cccccccsccssececeeecesceess
55. nches 368 3 mm its height is 18 0 inches 457 2 mm and its depth is 4 4 inches 111 8 mm The eguipped enclosure including the 7 A Hr battery is 22 1 pounds 10 Kg 3 5 Suppressors Two suppressors HAS part number S 4 are reguired for each door lock One suppressor is installed on the panel control board and the second must be installed at the door lock 8 www honeywell com NetAXS NX4S1 Installation Installation 4 0 Installation Perform the following steps to Install the NX4S1 panel Warning Use a static strap whenever touching the panel to ensure protection from Electrostatic Discharge ESD 1 2 Review the panel layout cable runs and power needs Mount the enclosure at the proper location on the wall Use appropriate anchors for the mounting material Run all I O wires to the enclosure and properly mark each wire for its use Run appropriate length of two wire 18 AWG shielded cable from the wall transformer to the enclosure The AC input must be supplied at 16 5 VAC utilizing one of the following UL listed 50 VA Class 2 transformers Basler Electric Model BE156250CA A0004 M amp G Electronics Model MGT1650 or Honeywell Access Systems part number X 4 The AC voltage is non polarized and connects to TB17 1 and TB17 2 Caution Do not plug in the wall transformer at this time and do not connect to a receptacle controlled by a switch Run a 14 AWG green wire from the enclosure to a prop
56. pment For panels using the Ethernet connection the cable clamp HAS part number 3 000342 must be used for the panel to pass the FCC Part 15 Class B reguirements See Installation on page 9 for clamp installation instructions 1 5 Industry Canada This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A 3 NetAXS NX4S1 Installation Notices 1 6 Underwriters Laboratories Incorporated The NetA XSTM panel was reviewed by Underwriters Laboratories Incorporated for Access Control System Units Category ALVY UL294 standard The NetAXSTM panel was reviewed as a stand alone system The input points only monitor the door position The NetAXS M panel is not intended as a Proprietary Alarm Unit Category APOU UL1076 standard The NetAXS panel was reviewed using the following Honeywell readers OmniAssure TM OT30 OmniClass TM OM40 and OM55 and OmniProx TM OP30 and OP40 Notes E All field wiring except the battery backup charger wiring is Class 2 power limited UL has not evaluated communication with panels that are not NetAXSTM panels Underwriters Laboratories UL has reviewed only the configurations shown in RS 485 Connection via PC
57. rara rre 26 5 1 RS 485 Connection via PCI 2 eeeesueuuu ueu ILL LI LII LILI LIII LLI LLA IL FI FF non 26 5 2 RS 485 Connection via NetAXSTM naa 27 5 3 RS 485 Connections with Multidrop Panels at Both Ends of the Cable 28 5 4 RS 232 ConnectiOn i denu did Fy GOFFA LED UY CF Y Y FT do 30 3 5 Ethernet Connection tapan aiii 31 5 0 LANSRLUL Connect ide Q Sua aq DO spa oases 32 5 7 RS 485 Short Haul Modem Connection via PCI 2 a 33 5 8 RS 485 Short Haul Modem Connection via NetAXSTM 34 5 9 RS 232 Short Haul Modem Connection asas 35 5 10 M 56K Dial up Modem RS 485 Connection via Hub 36 5 11 M 56K Dial up Modem RS 485 Connection via NetAXSTM 37 5 12 Fiber Converter to RS 485 Connection via PCI 2 I LIF Liu 38 5 13 Fiber Converter to RS 485 Connection via NetAXSTM 39 5 14 N 485 PCI 2 NetAXS Access Controller Panel Connection Detail 40 5 15 NetAXSTM NetA XSTM Access Controller Panel Connection Detail 41 AIN 42 INS 42 7 0 Hardware Specifications viii coa ia dida 44 7 1 Relay Contacts it tit ua at E EE anash ains 44 T2 Reader ita a nas un au
58. rolled workstation These workstations consist of a desk mat floor mat and an ESD wrist strap Workstations are available from various vendors 1 2 Product Liability Mutual Indemnification In the event that a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to property of others the Customer shall immediately notify Honeywell in writing of all such claims Honeywell shall defend or settle such claims and shall indemnify and hold the Customer harmless for any costs or damages including reasonable attorneys fees which the Customer may be reguired to pay as a result of the defective Product or the negligence of Honeywell its agents or its employees The Customer shall hold harmless and indemnify Honeywell from and against all claims demands losses and liability arising out of damage to property or injury to persons occasioned by or in connection with the acts or omissions of the Customer and its agents and employees and from and against all claims demands losses and liability for costs of fees including reasonable attorneys fees in connection therewith 1 3 Limited Warranty All Products sold or licensed by Honeywell Access Systems HAS include a warranty registration card which must be completed and returned to Honeywell by or on behalf of the end user in order for Honeywell to provide warranty service repair credit or exchange All warranty work shall be handled through the Cu
59. rts a single 12 volt reader with Wiegand output format Power to the readers is shared with the AUX Power ports TB3 and TB14 The maximum power draw is 600 mA for readers and AUX Power combined To fully utilize each reader port a shielded 7 conductor cable 18 22 AWG is reguired If the optional reader buzzer feature is not needed you can use the standard six conductor cable HAS part number NC1861 BL The cable shield should be grounded at the panel only Grounding at both ends can cause ground loops which can be disruptive The maximum recommended length of wiring is 500 feet per reader Table I Reader Wiring Terminal Wire Color Wiegand Reader TB5 1 6 1 11 1 12 1 Brown LED Control TB5 2 6 2 11 2 12 2 Green Wiegand Data 0 or Data TB5 3 6 3 11 3 12 3 White Wiegand Data 1 or Clock TB5 4 6 4 11 4 12 4 Black Common TBS 5 6 5 11 5 12 5 Red 12VDC Power TB5 6 6 6 11 6 12 6 Variable Tamper TB5 7 6 7 11 7 12 7 Variable Buzzer 4 3 Supervised Input Wiring The supervised inputs are located on TB4 and TB13 Figure 7 on page 15 Input 1 through Input 8 may be configured for normally open or normally closed contacts as supervised or non supervised Inputs 13 and 14 are on TB8 All eight inputs have default functions but they can be configured for general purpose inputs The following table identifies the default function for each terminal position Table 2 Default Supervised Input As
60. s to TB17 1 and TB17 2 A power on LED assembly is supplied with the NX4S1 It is required by UL to be mounted for external viewing Refer to Installation page 9 for details When there is sufficient AC power the power on LED illuminates If the AC power is off the LED is not illuminated DC power is also non polarized The panel uses 24 VDC at 1 5 Amp wired into TB17 1 and TB17 2 The panel includes an input power indicator that illuminates when input voltage is present If the indicator is not illuminated the input voltage is either off or too low to operate the system Caution De energize the unit before servicing it 3 3 Battery One CASIL CA1270 12 VDC 7 A Hr sealed lead acid battery HAS part number 3 000066 provides standby backup power When the primary power is off the NetAXS panel automatically switches to the battery for continuous operation The battery provides three hours of standby backup power The NetAXS panel is capable of providing 300 mA at 13 7 VDC for battery charging The panel has deep discharge protection built in for the protection of the battery If the battery discharges below 10 4 V the panel disconnects the battery and ceases operation Replace the battery every two to two and a half years or more often if the panel has a high rate of backup use Refer to Installation page 9 for battery cable connection information 3 4 Enclosure The NX4S1 enclosure ships pre wired Its width is 14 5 i
61. signments Terminal Position Default Function TB4 1 Door 1 REX Egress TB4 3 Door 1 Status TB4 4 Door 2 REX Egress 14 www honeywell com NetAXS NX4S1 Installation Installation Table 2 Default Supervised Input Assignments continued Terminal Position Default Function TB4 6 Door 2 Status TB8 1 External Power Supply AC FAIL TB8 3 Panel Tamper TB13 1 Door 3 REX Egress TB13 3 Door 3 Status TB13 4 Door 4 REX Egress TB13 6 Door 4 Status TB 5 6 6 6 11 6 Optional supervised input if not used 12 6 for a reader tamper The following figure shows the typical wiring for a supervised input Figure 7 Typical Supervised Input Wiring Diagram wo OWVOO DOOR 1 EGRESS COMMON DOOR 1 STATUS DOOR 2 EGRESS COMMON DOOR 2 STATUS The figure above shows standard 2 200 ohm resistors The NetAXS panel accepts 1 000 2 200 4 700 or 10 000 ohm values Note that both resistors must have the same value See the NetAXS Access Control Unit User s Guide for instructions on selecting resistor options In addition the Tamper and External Power Fail as well as the Reader and Panel tampers can be supervised and capable of being used as additional inputs if the default functionality is not needed They also share a single common The wire used for the inputs should be shielded and cannot exceed 30 ohms over the entire
62. so test the system on a regular basis by instructing the end user in appropriate daily testing procedures Failure to test a system regularly could make installer liable for damages to the end user if a problem occurs Warning Earth ground all enclosures for proper installation Warning Use suppressors on all door locks Use HAS part number S 4 suppressors for installation Honeywell recommends only DC locks Warning Personal injury or death could occur and the equipment could be damaged beyond repair if this precaution is not observed Before installation turn off the external circuit breaker which supplies power to the system including door locks Before connecting the device to the power supply verify that the output voltage is within specifications of the power supply Do not apply power to the system until after the installation has been completed Caution If any damage to the shipment is noticed a claim must be filed with the commercial carrier responsible Caution Electro static discharge ESD can damage CMOS integrated circuits and modules To prevent damage always follow these procedures NetAXS Access Control Unit NX4S1 Installation Guide Document 800 00008 Revision A NetAXS NX4S1 Installation Notices Use static shield packaging and containers to transport all electronic components including completed reader assemblies Handle all ESD sensitive components at an approved static cont
63. stomer which shall notify Honeywell and apply for a Return Merchandise Authorization RMA number prior to returning any Product for service repair credit or exchange Honeywell warrants that its Products shall be free from defects in materials and workmanship for a period of one year from date of shipment of the Product to the Customer The warranty on Terminals Printers Communications Products and Upgrade kits is 90 days from date of shipment Satisfaction of this warranty shall be limited to repair or replacement of Products which are defective or defective under normal use Honeywell s warranty shall not extend to any Product which upon examination is determined to be defective as a result of misuse improper storage incorrect installation operation or maintenance alteration modification accident or unusual deterioration of the Product due to physical environments in excess of the limits set forth in Product manuals www honeywell com NetAXS NX4S1 Installation Notices THERE ARE NO WARRANTIES THAT EXTEND BEYOND THIS PROVISION THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS IMPLIED OR STATUTORY INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NO REPRESENTATION OR WARRANTY OF THE DISTRIBUTOR SHALL EXTEND THE LIABILITY OR RESPONSIBILITY OF THE MANUFACTURER BEYOND THE TERMS OF THIS PROVISION IN NO EVENT SHALL HONEYWELL BE LIABLE FOR ANY RE PROCUREMENT COSTS LOSS OF
64. t 4 A 4 2 Reader LED Outputs The Reader LED output defaults to toggle the card reader LED from Red to Green for two seconds when a valid card is presented No LED color change other then a possible momentary change depending on reader used occurs if the card is not in the database The following are the default reader LED port to output associations Reader LED Controls Reader 1 Output 11 Reader 2 Output 12 Reader 3 Output 13 Reader 4 Output 14 NetAXS Access Control Unit NX4L1 Installation Guide 7 901099 Revision A 59 NetAXS Standalone Operation NetAXS Panel Defaults A 4 3 Reader Tamper Inputs The card readers have a Tamper signal wired to the NetAXS panel This is a two state input configured as a Normally Closed contact The following are the default Reader Tamper Input to Panel Input associations Tamper LED Reports as Tamper Input 9 Tamper 2 Input 10 Tamper 3 Input 11 Tamper 4 Input 12 A 4 4 Door Egress Inputs The panel has a Request To Exit Egress input for each door The default condition is a two state input configured as Normally Closed contact When the egress input is active the associated output relay will be active The following are the default egress input associations Egress input Controls relay Panel input Reports as 1 1 SP1 Input 1 2 2 SP3 Input 3 3 3 SP5 Input 5 4 4 SP7 Input 7
65. thernet cable The N1000 panels on the Multidrop bus do not report N1000 panels will not communicate to a NetAXSTM panel that is configured as a Gateway Replace all of the N1000 panels with NetA XSTM or replace the Gateway panel with an N 485 PCI 2 device The BAD CRC counter is incrementing every minute Two or more panels on the Multidrop Bus have the same panel address Verify that each panel has a unigue address setting on DIP switch positions 1 5 48 www honeywell com NetAXS NX4S1 Installation Technical Support Table 8 Troubleshooting Problems and Solutions Problem Solution Adroplinepanel The preferred solution is to configure the standalone panel through the in standalone Web server as a Gateway and use the board PCI and AckNak communi mode usin y cations This also gives the user a more secure and reliable communi RS 232 may unexpectedly fill cations line its buffer Another solution is to execute a new command that will allow the user to turn the Tesla flow control off _U lt pn gt _D disable flow control This prevents the panels from inadvertently filling their buffers To turn the Tesla flow control back on _U lt pn gt _E enable flow control Note The NetAXSTM EOL network is AC coupled There is no resistance difference a between the RS 485 positive and negative terminals if the EOL network is on or off J36 and J37 10 0 Techn