SWD-Collect - OMEGA Engineering
Contents
1. float on top of that application s screen as well 6 Click on the command that will prompt the instrument to transmit data or carry out any other desired actions If necessary use the scroll bar to reveal your complete list of commands 7 Click on the Send button located along the bottom of the dialog box Interrupting a Command Note there is also an Interrupt button located along the bottom of Commands dialog box see Figure 4 6 that you can click to stop SWD Collect from sending commands to the instrument For example if you have set up a command to prompt the instrument to send data every 5000 milliseconds you could use the Interrupt button to stop this command If data collection is occurring at a fast rate multiple 37 CHAPTER A Opening Instruments 38 readings per second activating the Interrupt button may require more than one attempt Please Note If the rate of data collection is occurring at a very fast rate you may be unable to activate the Interrupt button If this is the case quickly press on the lt Pause Break gt key as many times as is necessary to terminate data collection Use of the lt Pause Break gt key to halt data collection is only applicable when Keyboard Appli cation has been specified through the Instrument Data Destina tion dialog box see Figure 4 3 Page 31 Using the Additional Options Available Once you have opened an instrument you
2. If you have an extensive list of instruments you may also type the first letter of the instrument name to move the highlighted line to the next listed device beginning with that letter Upon reaching the bottom of the list the highlighted line returns to the top Clicking once on an instrument name will highlight it Click on the Open button to proceed to the next dialog box or Cancel to return to the main SWD Collect window Double clicking on the instrument name will automatically select it and open the next dialog box Specifying the User Info If you have specified a Macro see Chapter 5 Page 63 that includes User Prompts asking the operator to enter information you will see the User Prompts dialog box as shown in Figure 4 2 If not skip ahead to the next section Where to Send the Instrument Data see Page 31 User Prompt Prompt Value Batch 5 Location P300 User Name Technician 1 ba Figure 4 2 Specify the prompt values On the left side are the User Prompts defined within the Macro You should enter the appropriate Prompt Value on the right side of the dialog box CHAPTER A Opening Instruments js Click on the cell that is opposite to the User Prompt 2 Click on the down arrow to reveal a list of previously entered Prompt Values Click on the appropriate value to select it 4 Ifthe appropriate response is not listed double click on the cell and type in
3. The latest changes will be explained ina README file that will be installed with the program To list this information 1 Double click on the README question mark icon that was installed in the same Program Group as SWD Collect 2 The readme hlp file will be displayed in a standard Windowse based on line help format allowing you to jump to various topics 3 To exit the README simply pull down the File menu and select Exit CHAPTER 1 Introduction to SWD Collect If such a file exists you may look at the README file at any time although it is a good idea to look at it before installing the program Installation Contents of the SWD Collect Package Two 3 5 SWD Collect Program Disks One SWD Collect User s Manual Preparing your System Computer Re quirements Hardware Requirements SWD Collect requires that your computer has the following minimum specifications An IBM compatible 80486DX or higher 8 MB RAM minimum 16 MB recommended Hard Disk with at least 5 MB of free disk space At least one 3 5 floppy disk drive VGA or higher resolution COMI COM2 etc ports to support RS232 communications the minimum is one available COM port e For RS232 communications please ensure that you have a cable that is certified by the instrument manufacturer Software Requirements SWD Collect can run under the Microsoft Windows 95 Windows 98 Windows NT and Windows 2000 operating systems Check your disks
4. including Y or N values and macros Parser Selector The Numbers and Delimiter types of Parsers are not very selective in defining what data is to be kept The Delimiter type defines all of the data while the Numbers types will extract all the numbers Please recall that a number is considered any continuous string of numeric characters including the decimal N Type or comma C Type The Selector in the Parser allows you to specify the data that is saved The Selector is a list of Ys and Ns such as YYNNY A Y es instructs the program to keep the data and an N o means do NOT keep the data In this example the first second and fifth data values will be saved The third and fourth will be ignored Several short forms can be used for repeating sequences in the Selector Examples N NNNYYYYYYYNN can be written as N 3N7Y2N D 32 YYYYNYNYNY can be written as D 32 4Y3 NY N Y 1 Y 1 Y 1 Y 1 Y 2 can be written as N A Y 1 Y 2 Parser Comment The Parser Comment can be a brief statement describing what the Parser does The length allowed for the comment will depend on the amount of space available on the Parser Definition line after the other Parser components have been specified The Parser Comment can consist of any alphanumeric characters except the forward slash e 51 CHAPTER 5 Setting up the Instrument Parser 52 Choosing a Suitable Parser Type Using the Numbers Parser Type Select the
5. l 2 Position the cursor in the correct position in your Macro definition Double click on ASCI from the Special Functions list and you will see an ASCII Value dialog box similar to the example shown in Figure 5 7 ASCII Value Enter ASCII Number 0 255 l Figure 5 7 ASCII Value dialog box Enter the desired ASCII Number between 0 255 For a list of ASCII Numbers see Appendix A at the end of this manual Click the OK button The ASCII code will appear in the Macro within triangular brackets such as lt ASCII 32 gt Including User Prompts in the Macro User prompts will prompt the operator to enter information at the time the instrument is opened These are inserted into the Macro definition For example you could add the operator s name the type of sample being measured or the batch number To use this feature you must first define a User Prompt l Click the New button located below the User Prompts box in the Define Macro dialog box see Figure 5 5 Page 59 The New User Prompt dialog box will appear as shown in Figure 5 8 see Page 64 63 CHAPTER 5 Setting up the Instrument Parser 64 Enter New Prompt User Name ze Figure 5 8 New User Prompt dialog box 2 Enter the new prompt which will ask the operator for specific information For example you could have Operator s Name as the prompt 3 Click on the OK button The prompt will appear on t
6. would identify 8 segments of data but only save the first fifth and seventh the numbers 23 5 27 6 and 25 6 The second number 0 7 and all units are ignored If several of these delimiters occur in sequence one after the other the program will treat each as a separate delimiter For example in the string 45 67 the second element is a blank because there is nothing between the two commas A blank will be transferred as the data for the second element along with any associated Macros You can list as many delimiters as you wish If they are standard printable keyboard characters simply list them in the Parser i e D set Y YNN comment If they are not printable characters you must list them in the form of an ASCII character enclosed in brackets such as 32 for a file that is space delimited Please note that the carriage return ASCII 13 and line feed ASCII 10 are not recognized as delimiters by the program If your data string is long and consists of more than one line Oe it has a lt LF gt lt CR gt in the middle of the data then you are able to remove these characters with the Remove field described earlier If the data cannot be parsed with any of these Types contact the OMEGA Customer Service Department Other programs are available with much more powerful Parsers 57 CHAPTER 5 Setting up the Instrument Parser 58 Using Macros When defining a Parser you are abl
7. 80 Combining Expressions With Parentbeses 81 Displaying Formulas on the Spreadsheet 008 82 Editing Within a Cell 82 Changing Column Widths and Row Heabtzs 82 iv TABLE OF CONTENTS Appendix A ASCII Numbers cc ceeeeees 83 Appendix B Troubleshooting toletzt ee Eet EE A E 87 Possible Solutions imien aee a a i e ie ain 87 Index BE RRR RRR Index 1 Printed in Canada Chapter 1 An Introduction to SWD Collect Introductory Notes The Software SWD Collect is designed for those who simply want to turn on their computer and begin collecting data It is ideal in laboratory and production environments where an easy to use system is required In particular SWD Collect can carry out the following basic steps 1 SWD Collect will receive data directly from an instrument by collecting data arriving at an RS232 port It can also import an existing ASCII also known as text only data file 2 The collected data is then processed This consists of modifying the data by selectively breaking it into required components referred to as parsing the data Using macros required key strokes and other characters are then added to the data User specified prompts such as operator s name and sample description may also be added to the data 3 The modified data can then be sent to any of four destinations It can be sent to a disk file to the screen to a built in spreadsheet or direct
8. Cancel Figure 5 3 Parser Setup dialog box Note the name of the Parser will appear dimmed in the top box The name cannot be changed on this screen The cursor will be flashing in the Definition text box CHAPTER 5 Setting up the Instrument Parser Specifying the Parser The Definition line is where you enter the actual Parser itself The Parser always follows a particular format it always begins with the Parser Type then depending on the Type it includes details such as Parser Selectors and Parser Positions The Parser Type Selectors and Positions are separated by slashes Please refer to the section Designing a Parser later in this chapter see Page 49 You can also specify Macros on this line which are identified within square brackets Please refer to the section Using Macros later in this chapter see Page 58 Removing the Carriage Return or Line Feed from the Data The Remove field is active only when you specify a Delimiter type D parser in the Definition line It allows you to specify whether the parser should automatically remove the carriage return CR and or line feed LF characters from the data The Remove field has a drop down list of four options CR amp LF CR LF or Nothing When you have entered a D in the Definition Line you are then able to select one of these four choices The carriage return and or line feed will be removed before the parser itself is carried
9. Delete Add Edit Delete OK Cancel Figure 5 10 Example of a Parser Setup The P in the Parser indicates that the data is parsed by Position The characters in positions 3 to 6 will be saved Macro number 2 is inserted before the data and Macro 1 is inserted after the data Macro 2 consists of the User Prompt lt SAMPLE NAME gt followed by a right arrow key Macro 1 consists of a right arrow key a Date stamp and the Enter Key followed by two left cursor keys The resulting spreadsheet would appear similar that shown in Figure 5 11 see Page 68 67 CHAPTER 5 Setting up the Instrument Parser 68 EQ swo Collect lolx Instruments Spreadsheet Configure Options Window Help rlalelelelglael viele F 2 1999 04 01 1999 04 01 31 5 1999 04 01 Insert data from the Clipboard at the cursor position Balance COM2 Figure 5 11 Example of the resulting spreadsheet When the instrument is opened Macro 2 prompts the operator to enter the lt Sample Name gt such as Nerve Tissue The Macro enters this into the spreadsheet in column A and presses the right arrow key to allow data to be entered into column B Macro 1 presses the right cursor key after the data has been entered then enters the Date stamp in column C The Macro then presses enter to move to row 2 and two left arrow keys to return to column A for the next value to be tran
10. N or C types if only numbers are required from the data This is the easiest Type to use and the following is the syntax for such a parser setup N SELECTOR COMMENT C SELECTOR COMMENT The Parser will be an N or C followed by a slash This is followed by a series of Ys and Ns to indicate which numbers are to be saved Again please recall that a number is considered any continuous string of numeric characters including the decimal N Type or comma C Type So a number can be a single digit or several numeric characters Example 1 N Y keep weight As a simple example suppose that you collect the following data from your balance 193 67mg The Numbers Parser N Y keep weight will parse the data so that the number is saved 23 5 and the units mg are ignored Example 2 N YNYY no units CIYNYY comment The C Type is for num bers in comma format common in Europe such as 35 6 As amore complicated example suppose that your instrument transmits a line with the following 4 data values 23 5 units 0 7 units 27 6 units 25 6 units The Numbers Parser N YNYY no units would parse the data so that CHAPTER 5 Setting up the Instrument Parser the first number is saved 23 5 the second is ignored 0 7 and then the third 27 6 and fourth 25 6 are kept The units appearing after each number are always ignored Later in this chapter you will see how to use Macros to organ
11. are listed by numbers contained within square brackets such as 1 2 etc 1 Ifthis is the first Macro for the Parser the list should be blank and the top line opposite 1 should be highlighted Simply click on the Edit button located below the Macros box on the Parser Setup dialog box see Figure 5 3 Page 46 This will open the Define Macro dialog box as seen in Figure 5 5 see Page 59 CHAPTER 5_ Setting up the Instrument Parser Macro lt Enter gt lt Left gt Special Functions _ p User Prompts Add Special Function New Delete SS ce Figure 5 5 Define Macro dialog box 2 Ifyou are adding new Macros after defining the first one 1 click on the Add button located below the Macros box on the Parser Setup dialog box see Figure 5 3 Page 46 to add as many new numbers in the margin as are required 3 Click inside the box opposite a Macro number to highlight that line see Figure 5 3 Page 46 then click on the Edit button to open the Define Macro dialog box shown in Figure 5 5 4 Ifyou are editing Macros that have already been created highlight the line with that Macro and click on the Edit button located below the Macros box on the Parser Setup dialog box see Figure 5 3 Page 46 This will open the Define Macro dialog box Please refer to Figure 5 5 The cursor will be flashing in the Macro text box at the top You can define the
12. for 30 days registration of the installation with OMEGA Engineering Inc is required for further use This must be done within 30 days of installing the program CHAPTER 1 Introduction to SWD Collect When you first start SWD Collect you will advance to the Register dialog box Enter the 10 digit Registration Code found on the Product Installation Disk If a registration code was not supplied with the product contact OMEGA directly to obtain one Before registering the product please ensure that you are complying by your current license agreement with OMEGA before activating this copy of the product If you do not register the program now you will be permitted to use a fully functional unregistered copy of the program for a period of 30 days after which you are required to register the product Should you require technical support you will be required to provide the serial number This can be retrieved from the product s About Box Select the About sub menu item from the Help menu While using the program you may also see the Register dialog box by choosing the About item from the Help menu You will first see an information window about SWD Collect and you may click on the Register button there Copyright SWD Collect is copyright protected by Labtronics Inc with all rights reserved This manual is copyright protected by OMEGA ENGINEERING INC with all rights reserved No part of this software or manual may be c
13. from the Instrument will always be directed to the specified application This field may be left blank if desired Ifno Command Line is specified then the Application specified in the above field will not be started if it isn t found already running You may click on the Browse button pictured as an ellipsis to see the Destination Application dialog box where you may specify the required information for the destination Click on the OK button in the Destination Application window to return to the Instrument Data Destination dialog box see Figure 4 3 Page 31 Opening a Data File with the Application You may enter the name of a specific data file to be opened by the destination application For example you may have the application open a template file for your data which you can then later save as another file name Again you may click on the Browse button pictured as an ellipsis to advance to the Keyboard Application Data File dialog box Specify the required information Sending the Data to a Spreadsheet Select this destination to have the data entered directly into the built in spreadsheet program known as the QuickSheet Sending the Data to the Monitor When monitor is selected the data transmitted from the instrument will be shown directly on the monitor Unprintable ASCII characters are displayed within curly braces as their decimal equivalents For example 13
14. macro with up to 125 characters Although unlikely if the macro is to be larger than this you can simply define another macro and place them side by side in the Parser See Adding a Macro to a Parser Page 64 There are three types of entries that can be used in the Macro Keyboard Characters Special Functions and ASCII Characters 59 CHAPTER 5 Setting up the Instrument Parser 60 Including Keyboard Characters in the Macro A keyboard character is any character that you can enter directly from the keyboard It includes all of the numbers letters and punctuation keys If you want to enter function keys or other special keys such as lt CTRL gt and lt ALT gt place the cursor in the correct position in the Macro then click on the Add Key button You will see the Macro Keys dialog box as shown in Figure 5 6 E F1 F2 F3 zen F5 Bee F9 ege Key SSS OK Cancel Figure 5 6 Macro Keys dialog box 1 Click on any key that you want to include in the Macro Certain special keys will only appear if they are combined with a second letter For example if you wanted to add lt ALT gt lt F7 gt to the Macro first click on the lt ALT gt key then on the lt F7 gt key Your selection will appear dimmed in the text box beside Key at the bottom of the dialog box 2 Click the OK button You will see the Define Macro dialog box again see Figure 5 5 Page 59 and your key selection will be added
15. of Cells 1 Pull down the Spreadsheet menu 2 Select Edit 3 From here select the Fill sub menu item This will advance you to the Fill Cell dialog box similar to the example shown in Figure 6 3 see Page 76 75 CHAPTER 6 The SWD Collect Spreadsheet 76 Fill Cells E Label Increment fi Figure 6 3 Fill Cell dialog box The Fill options allows you to fill a series of cells with a single entry The entered value can be specified as well as an increment value The latter will increment numeric entries This option is very useful for entering sequential sample IDs If cells already contain information the filling process will skip over these cells and not increment the counter for these cells Clearing the Spreadsheet Pull down the Spreadsheet menu 2 Select Edit 3 From here click on Clear to remove the contents of the entire cell or delete selected characters highlighted from the cell Select the Clear All sub menu item to clear the entire spreadsheet Setting Fonts in a Spreadsheet To set the fonts on a spreadsheet do_one of the following 1 Pull down the Spreadsheet menu 2 Select Font or 1 Click on the Font button shown in the margin CHAPTER 6 The SWD Collect Spreadsheet In either case you will advance to the Font dialog box From here you can set the font font style size effects and color of each cell Printing a Spreadsheet To print a spreadsheet do_one
16. of selection then ensure you enter them in order here When you have finished entering the command for the instrument click on the OK button to save the details Please refer to Chapter 3 Pages 24 to 28 for additional information on defining instrument commands CHAPTER 2 Quick Start Just the Basics Opening the Instrument Before SWD Collect can start collecting data you must first open the instrument To open an instrument do one of the following From the SWD Collect main screen see Figure 2 1 Page 9 pull down the Instruments menu 2 Select the Open sub menu item 1 From the SWD Collect main screen see Figure 2 1 Page 9 click the Open button from the Toolbar as shown here in the margin In either case you will advance to the Open Instrument dialog box will appear similar to the example shown in Figure 2 5 Open Instrument pH meter Figure 2 5 Open Instrument dialog box You will see a listing with the instrument s that you have just configured for the SWD Collect program Clicking once on an instrument name will highlight it Click on the Open button to proceed to the Instrument Data Destination dialog box see Figure 2 6 Page 16 or Cancel to return to the main SWD Collect window Double clicking on the instrument name will automatically select it and open the Instrument Data Destination dialog box see Figure 2 6 Page 16 15 CHAPTE
17. of the following 1 Pull down the Spreadsheet menu 2 Select Print or 1 Click on the Print button shown in the margin In either case you will advance to the Print Options dialog box similar to the example shown in Figure 6 4 M Border gt Margins M Shadows Top 0 300000 M Grid M Column Headers Bottom 0 300000 M Row Headers Left fo 300000 Right 0 300000 Print Range gt A C Selection Cancel Figure 6 4 Printing a spreadsheet Defining the Print Options Figure 6 4 presents a variety of options related to the spreadsheet printout 77 CHAPTER 6 The SWD Collect Spreadsheet Printing Option Description Border Click on this check box to print the spreadsheet bor der Shadows Click on this check box to print any colored areas with shading Grid Click on this check box to print the vertical and hori zontal lines of the spreadsheet Column Headers Click on this check box to print the column labels Row Headers Click on this check box to print the row labels Print Range Click on the radio button All or Selection to specify the range to be printed Margins You can specify the margins by entering a number in inches in the Margin box e g Top Bottom Left Right Previewing the Print 1 Pull down the Spreadsheet menu 2 Select Print Preview This will advance you to the Print Preview dialog box similar to the example shown in Figure 6 5 Print Preview Be
18. opened an instrument you must first close it before reconfiguring Then you can re open it to see the new configuration in effect 3 Click on the Create button to set up a new instrument You will advance to the Instrument Protocol Setup dialog box as seen in Figure 3 3 Defining your Instrument Protocol Instrument Protocol Setup Instrument Name Balance Comm Port Port coM2 x Protocol None x Baud Rate 2400 gt Timeout 250 z Party None Number of Timeouts 1 Data Bits 8 z StopBtsh z Cancel Figure 3 3 Instrument Protocol Setup dialog box 20 CHAPTER 3 Configuring Instruments There are some key communication parameters associated with serial RS232 communication that must be matched exactly between your instrument and the configuration in SWD Collect Jn particular if the Baud Rate Data Bits Stop Bits and Parity are not matched exactly between the instrument and SWD Collect serial data transfer will not work The computer does not automatically determine what these parameters are for your instrument YOU MUST ENTER THEM HERE Specifying the Instrument Name The cursor will be flashing in the Instrument Name box Type in the name of the instrument so that you will be able to identify the instrument you are using throughout the SWD Collect program Do not press lt Enter gt after typing in the name as this will cause you to close the dialog box Specifying the Comp
19. the active window again 3 If necessary send the appropriate command to prompt the instrument to begin transmitting data again 4 Carefully look at the incoming data to verify that the change was correct 5 Return to the Parser Setup dialog box see Figure 5 3 Page 46 to make more changes if necessary 6 It is also a good idea to complete the Parser first and then add the Macros one at a time Parser Types The first step in designing a Parser is to select the Type There are five different types of Parsers that specify how to break up the data that is transmitted to the computer The types along with a description are presented in Table 5 1 49 CHAPTER 5 Setting up the Instrument Parser 50 Numbers Numbers Position Scales Delimiter Data is parsed on a numbers only basis All numbers are extracted from the data and only numbers are used This type should be used for decimal numbers i e 35 6 Please note a number is considered any continuous string of numeric digits including decimals and negative signs When the program encounters any other charac ter the number is considered complete See Page 52 for examples Data is parsed similarly to the N type except the format of the numbers uses a comma i e 35 6 which is a common format in Europe This type cannot be used for comma delimited data Please note a number in this case is considered any continuous string of num
20. time the instrument is opened 4 Send which opens a Send dialog box when you add it to the Macro like the one shown here You may enter any text up to 64 characters to be sent to the instrument ASCII characters may be entered within curly brackets 5 Data Header and Units all for use in conjunction with the Scales Type Parser 6 Beep which causes the computer to beep This could be used to audibly indicate when data is parsed All entries can be used in any order and you can place any characters between the entries For example if you wanted the Date to be stamped with the data going into a spreadsheet application you first position the cursor in the Define Macro text box You could type DATE to have this heading appear with the date stamp Then you would scroll down through the Special Functions list and double click on lt Right gt to have SWD Collect press the right arrow key to move to the next cell Next you would double click on lt Date gt to include it in the Macro and double click on lt Right gt again to press the right arrow key following the date The lt Date gt Special Function will stamp the date in the format set up in your Windows Control Panel CHAPTER 5 Setting up the Instrument Parser Including ASCII Characters in the Macro One of the entries on the Special Functions list can be used to enter ASCII characters To enter an ASCII character in your Macro follow these steps
21. to verify you have the correct version for your operating system CHAPTER 1 Introduction to SWD Collect Installing the Software SWD Collect comes with an automated setup program The setup program must be run from within Windows 95 Windows 98 Windows NT or Windows 2000 L First have your Windows operating system running 2 Insert the SWD Collect disk 1 into your computer s floppy drive 3 Click on the Start button at the bottom left corner of your screen and choose the Run item from the pop up menu 4 You will advance to a Run dialog box where you may enter the name of a program folder or document to be run This is called Open Type a setup or b setup then click on the OK button 5 The setup program will specify a drive and directory to install to If you wish to change the default simply enter the appropriate information here The setup program will create the necessary directories and copy the files over 6 Double click on the SWD Collect icon to start the program You will see the main window for SWD Collect Chapter 2 of this manual gives a Quick Start introduction to the program while Chapters 3 6 provide complete details Registering the Software Each new installation of the software requires its own registration You may install SWD Collect from the original master disks or from copies of these master disks Once installed the program is fully functional
22. will notice additional menu options across the top of the SWD Collect window There are additional options under the Instruments menu and there are three new pull down menus Spreadsheet Options and Window You may use these menus and options for each open instrument Click on the open instrument to make it the active window then pull down the desired menu and select the option Viewing the User Prompts This option is the same as clicking on the User Info button in the Setup Instruments dialog box see Figure 3 2 Page 20 The User Info option will reveal a list of User Prompts only if you have specified a Parser that includes User Prompts asking the operator to enter information Prompt Values for an open instrument may be changed at any time Please refer to the section Displaying the User Prompts in Chapter 5 see Pages 66 67 Importing a File This feature allows you to import an ASCII data file for SWD Collect Binary files can t be imported with this program CHAPTER A Opening Instruments Click on the open instrument to make it the active window Pull down the Instruments menu Select the Import File sub menu item You will advance to the Import File dialog box similar to the example shown in Figure 4 7 Import File Look in Collect fa ol Fie name Files of type Data Files DAT 7 Cancel Help Figure 4 7 Importing a File 4 Specify the required information of the file to b
23. you only need to press the hot key For example Open is an option in the Instruments Menu that has an underlined OQ Once you have selected the Instruments Menu you could press lt O gt to activate the option For a button pressing lt Alt gt in combination with a hot key is equivalent to clicking on the selection For example the Create button on the Setup Instruments dialog box has an underlined C Instead of clicking on the Create button you could press lt Alt gt lt C gt Note that these two keys must be pressed simultaneously Mouse Procedures and Terms Many actions in Windows based programs require the use of a mouse This manual uses certain terms to indicate that a mouse action is required When a menu option must be chosen or a button needs to be pushed the manual will say something such as Pull down the Configure Menu and select Instrument or Click on the OK button This means you should use the mouse to position the arrow cursor on the specified menu option or button and then push the left mouse button once Some selections require you to click and drag the mouse This means to hold the left mouse button down while you move the mouse known as dragging This operation is often used within a spreadsheet see Chapter 6 of this manual for more details on selecting spreadsheet cells Some selections in Windows based applications are accomplished by d
24. your response to the prompt 5 Click on the OK button to proceed to the Instrument Data Destination dialog box see Figure 4 3 Clicking on the Cancel button will return you to the previous dialog box p For further information please refer to the section Displaying the User Prompts in Chapter 5 see Pages 66 67 Where to send the Instrument Data SWD Collected data is parsed and then combined with Macros see chapter 5 Instrument Parser Setup Data can then be sent to a specified destination When opening an instrument you must complete the Instrument Data Destination dialog box see Figure 4 3 and click on the OK button Clicking on the Cancel button will return you to the previous dialog box IT File El T Keyboard Application Command EI Data File EI I Spreadsheet Figure 4 3 Instrument Data Destination dialog box Simply click the check box beside the destination name to toggle it on or off An indicator will mark the square when it has been selected You can specify one or all of the following destinations File Keyboard Application Spreadsheet or Monitor 31 CHAPTER A Opening Instruments 32 Sending the Data to a File Data is sent directly to a specified disk file When you specify the file destination you must enter a path to the file Clicking on the Browse button pictured as an ellipsis beside the File text box opens the Des
25. 18 42 commands autoopen 37 interrupt button 26 37 interval 26 paced 26 repeated 26 cycle time 26 sending 17 configure instrument 10 19 conventions 2 copy protection 7 copyright 8 D date stamping 61 delimiter 56 destination 16 31 45 file 32 keyboard 32 monitor 33 spreadsheet 33 discard data containing 47 E exit 5 external control 13 24 F file destination 32 fill 76 float 73 formula functions 80 operators 79 parentheses 81 H hot key 3 l import file 38 installation contents of package 6 installing the software 7 instrument closing 18 42 configure 10 19 create 10 20 open 15 29 instrument command setup 13 24 instrument comport 11 21 instrument name 11 21 instrument protocol setup 11 12 20 instruments menu import file 38 user info 38 interrupt 26 37 Index 1 INDEX Index 2 K keyboard destination 32 M macros 47 58 add button 59 add key button 60 adding to a parser 64 ASCII characters 63 counter 62 cumulative time 62 date time stamping 61 defining 58 edit macro button 58 keyboard characters 60 removing 65 serial number 62 special functions 61 user prompts 63 menu spreadsheet 42 font 77 format 73 save as 76 window 42 monitor destination 33 mouse click and drag 4 double clicking 4 procedures 4 N number of timeouts 12 22 O on line help 5 open instrument 15 29 options menu autoload 41 autoopen commands 37 41 autoscroll 40 autostart 40 vie
26. 23 for additional informa tion on defining protocols and timeouts Saving the Instrument Protocol Setup Once you have completed your entries to the Instrument Protocol Setup dialog box see Figure 2 3 Page 10 click on the OK button to save the configuration Selecting OK will return the Setup Instruments dialog box see Figure 2 2 Page 10 with the name of the created instrument listed and highlighted CHAPTER 2 Quick Start Just the Basics Defining Instrument Commands Does your instrument require a command from the computer to prompt it to start or stop transmitting data Check your instrument s manual for a section on External Control 1 If your instrument does require such commands work your way through the following section 2 Ifyour instrument does not require a command from the computer click the OK button and skip ahead to the section Opening the Instrument Page 15 If your instrument requires a command from the computer click on the Command button located along the bottom of the Setup Instruments dialog box see Figure 2 2 Page 10 to open the Instrument Command Setup dialog box shown in Figure 2 4 Instrument Command Setup Command Description 1 32 Request a Reading I 2 32 1000 Request 1 Sample Second 3 32 200 Request 5 Samples Second 4 ju Specify Units 5 Ch Change Units 6 ce Figure 2 4 Define the instrument commands You can ent
27. 88 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 A2h A3h A4h A5h A6oh A7h A8h A9h AAh ABh ACh ADh AEh AFh BOh Blh B2h B3h B4h B5h Boh B7h B8h B9h BAh BBh BCh BDh BEh BFh Ch Clh C2h C3h C4h CSh Coh C7h C8h C9h CAh CBh CCh CDh CEh CFh DOh oR moO E Pr SOOCKTURONNNY Se ll E gt A 4 NI s Q 0 ASCII HEX Char 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 Dih D2h D3h D4h D5h D6h D7h D8h D9h DAh DBh DCh DDh DEh DFh E0h Elh E2h E3h E4h E5h E6h E7h E8h E9h EAh EBh ECh EDh EEh EFh FOh Flh F2h F3h F4h F5h Foh F7h F8h F9h FAh FBh FCh FDh FEh FFh OTXNDXK lt ODA 5 NN QV RE DH Feel DH ai oo mr d o blank APPENDIX A ASCII Numbers 85 APPENDIX A ASCII Numbers 86 Appendix B Troubleshooting Problem No data is received by the software or the data that is received consists of garbage characters that don t make sense Possible Solutions 1 The program may not be active Exit SWD Collect then try starting the program again 2 The Instrument Protocol Setup see Figure 2 3 Page 10 or Figure 3 3 Page 20 may not be correct This usually results in data being captu
28. Chapter 4 Pages 31 to 35 for additional information on Instrument Data Destination Sending Commands If you do not see data immediately you may need to prompt your instrument to transmit the data to the PC with one of the commands you entered during the setup Note if your instrument does not require commands ensure you have correctly entered the instrument configuration 1 Pull down the Instruments menu from the top of the screen and select the Command option 17 CHAPTER 2 Quick Start Just the Basics 18 2 The commands that you entered for this instrument will appear in the Commands dialog box 3 Click on the command that will prompt the instrument to transmit data then click on the Send button Follow these steps for all other commands to your instrument Closing the Instrument Data will be received and collected until you close the instrument 1 Click on the window associated with the instrument 2 Ifapplicable follow the Sending Commands procedure to prompt the instrument to stop transmitting data m 3 Click on the Close button on the toolbar shown here in the margin You will be prompted to confirm that you are closing the instrument 4 Click the OK button to close the instrument Chapter 3 Configuring Instruments If you have not yet installed SWD Collect onto your computer go back to the Installation section now Page 6 to Page 8 and follow the req
29. H_ data _U U lt CR gt lt LF gt where HH is the header sent by the instrument e g ST WT QT S_ when it has a stable value and CHAPTER 5 Setting up the Instrument Parser UUU U or U U is the units of measurement e g g Ib data is the weight reading The S 1 S 2 or S 3 appear as the first two components in a Scales Parser S DATA FORMAT The data sent from your scale must match one of these formats If your scale is capable of sending additional information such as an ID number turn these features off if you can when using SWD Collect SWD Collect follows three steps when parsing the data with a Scales Parser 1 First SWD Collect looks for the header HH to determine if the reading is stable Second the program compares the stable reading with the tolerance level that you specify You probably don t want SWD Collect to keep every stable value that is transmitted from the scale so you need to tell the program what the tolerance level is The tolerance level is the minimum value that you expect for a stable reading SWD Collect will ignore all the transmitted data values between 0 and this number positive and negative and save the first stable value outside this range The tolerance level is specified at the end of the Parser For example if you set the tolerance level at 0 35 SWD Collect will not keep the stable zero reading that is continuously sent from the sca
30. R 2 Quick Start Just the Basics Where to Send the Instrument Data When opening an instrument you must complete the Instrument Data Destination dialog box and click on the OK button Clicking on the Cancel button will return you to the previous dialog box Tl Keyboard Application Command H Data File H I Spreadsheet M Monitor Figure 2 6 Instrument Data Destination dialog box Simply click the check box beside the destination name to toggle it on or off An indicator will mark the square when it has been selected You are able to specify one or all of the following destinations File Keyboard Application Spreadsheet or Monitor For now specify the monitor destination by clicking the check box beside the word Monitor An indicator will mark the small square when it has been selected Click on the OK button to open the instrument A window will open with that instrument s name appearing at the top similar to the example shown in Figure 2 7 see Page 17 16 CHAPTER 2 Quick Start Just the Basics EJSWD Collect olx Instruments Spreadsheet Configure Options window Help gt m elei elglel vlelel F 2 Close current instrument Figure 2 7 An open instrument You may already see data being displayed on the monitor or you may have to press the Print or Send key on your instrument to have it start transmitting data Please refer to
31. SW D Collect Version 4 0 User s Guide OMEGA Meet 90 eege Table of Contents Chapter 1 An Introduction to SWD Collect Introductory Notes o oo eeecceeseeeneseeeeeseeeeeseeeeeeseeeeeeseneeeseeeeeeseneeeees 1 TNE Obbau ra See essence acta Eder 1 Conventions in this Manual 2 Special Keys and Procedures seseeeeeiseieeeeeereeieererrerneee 3 All ERC EE 3 The OK and Cancel Buttons 0 0 0 0 eceeeeeeeeenreeeeeees 3 Words With An Underlined Leite 3 Mouse Procedures and Terms ceceeneeeeeeeeene 4 Orne Hel Pi vtech ttle abet See 5 Status Line and Tool Tips Help 5 Exiting from SWD Collect ecceccceteeeeeeeeeeseeeeeeenaees 5 Last Minute Changes ceccceceeeeeeeeeeeeeeeeeeeseeseeeeseeennees 5 UE EE 6 Contents of the SWD Collect Package cceeseeeeeees 6 Preparing your System Computer Requirements 6 Hardware Requirements aecee eee 6 Software Requirements cccccccceeceeeeeeeeeeeeneeeteeees 6 Installing the Software ccceccececeeeeeeeeeeseeeeeeeeeeeeseeeeeeeenees 7 Registering the Software c cccceeeeceeeeeeeeseeeeeteeeeeeneesees 7 Copyright sinarna iedee ne ie been datas 8 Be 8 Chapter 2 Quick Start Just the Basics Configuring your Instrument ceeeeeteeeeeeeeeeeeeeeeeeenseneneeeeeeee 10 Setting up a New Instrument 10 Defining your Instrument Protocol 0 c eeceeeeeeees 11 Saving the Inst
32. Specify the required information to load a spreadsheet Click the OK button to load the desired spreadsheet Saving a Spreadsheet To save a spreadsheet do one of the following 1 Pull down the Spreadsheet menu 2 Select Save or 3 Click on the Save button shown in the margin In either case if you haven t saved the spreadsheet previously or if you opened it as read only the Save as dialog box appears similar to the example shown in Figure 6 2 see Page 73 CHAPTER 6 The SWD Collect Spreadsheet Save As x Save in 2 Colect D Si ol z Save as type Excel xls x Cancel Figure 6 2 Saving a spreadsheet Here you can specify the required information for saving the spreadsheet Please note the Save as Type box at the bottom Here you can specify whether to save the spreadsheet as a Spreadsheet File WSP an Excel File XLS or a Text File TXT Click the OK button to complete this process Formatting the Spreadsheet 1 Pull down the Spreadsheet menu 2 Select Format A list of sub menu items is available allowing you to format the cell contents Menu Option Description Align Allows you to specify the format of the cell contents to be aligned Left Center or Right Increase Decimals Increases the number of decimals displayed by one Decrease Decimals Decreases the number of decimals displayed by one Set Decimals Allows you to choose the number of decima
33. a are in a data unit for communication purposes Stop Bits Indicate how many stop bits are added to the data unit The default selection is 1 11 CHAPTER 2 Quick Start Just the Basics 12 Defining a Protocol for Data Transmission The Protocol is also known as handshaking which establishes the method for controlling the flow of data between devices so that one device transmits only when the other device is ready SWD Collect is designed to be ready for your device s transmission at all times so you need only select the default protocol NONE Any additional protocols that may be listed are custom designed methods reserved for highly specialized applications Specifying a Timeout for Data SWD Collection The program will collect data until an interval of time occurs when no more data is received This time interval is known as the Timeout After the Timeout occurs the program will organize parse the data and send it to either the keyboard a spreadsheet the monitor or to a specified disk file SWD Collect then gets ready to receive the next segment of data For now leave the Timeout default value of 250 milliseconds Defining the Number of Timeouts for Data SWD Collection Here you may specify the number of timeouts the program is to detect before parsing begins For now leave the default for this option at 1 one which will be the most common selection Please refer to Chapter 3 see Pages 20 to
34. a value consists of one character in position 6 T And the third consists of characters in position 5 6 7 8 and 9 4T mg You can arrange the position numbers in any order see how the 6 6 is listed after the 12 15 in the example As the data is transferred it will be processed in the order listed If necessary you can use a position more than once The above example uses position 6 in both ranges 6 6 and 5 9 Only list those positions which contain data that is to be saved In the above example data in positions 1 4 and 10 11 are not required and therefore are not listed Using the Scales Parser Type If your instrument is a scale that transmits data in continuous send mode the Scales Type S Parser can be used Please note this type is rarely used as it is specifically tailored to one brand of balances The following is the syntax for such a parser setup S DATA FORMAT MACRO TOLERANCE COMMENT Example S 1 1 21 0 35 A scale that transmits data in continuous send mode will generate continuous data values that will arrive at SWD Collect as one long string The program needs some way to determine which data values are to be kept Scales follow certain standard formats when transmitting the data and you can specify a Scales type parser to match the data format from your scale Currently three formats are handled by SWD Collect S 1 HH data UUU lt CR gt lt LF gt 8 2 HH U data lt CR gt lt LF gt S 3 H
35. ach command and then repeat it every second The character can be used cumulatively if desired Sending Commands at Specified Intervals In addition to the cycle times you may also send a command at specified time intervals The time intervals are variable based on the following formula CHAPTER 3 Configuring Instruments TIME INTERVAL START TIME x MULTIPLICATION FACTOR Where START TIME Is the number of milliseconds past time Osec the time when the command is sent MULTIPLICATION FACTOR Is a whole number used to multiply the START TIME and is raised to the power of 0 1 2 etc depending on the n specified If n 4 then this factor would be calculated to the power of 0 1 2 and 3 n Is an integer number representing a total of n time intervals to prompt the instrument for data Suppose that your instrument requires the command X to transmit each data value and suppose you require 50 data values from your instrument at a fixed time interval of 10 seconds apart You could enter a time interval command where the START TIME is 10 seconds 10000 msec after the command is first sent and with a MULTIPLICATION FACTOR of I to be raised to the power of n 50 times These components are specified in square brackets following the command and separated by commas The command that you type into the Command box would be as follows X 10000 1 50 SWD Col
36. alue of Decimals SUM Start Cell End Cell TRUNCATE Coord or Value of Decimals Returns the absolute value of the specified cell or value Adds the two elements which can be cell coordinates or values Returns e to the power of the specified cell or value Ifa is true cell is assigned b if false cell is assigned c The elements a b and c can be cell coordinates or values Returns TRUE if cell is empty FALSE otherwise Returns the Natural Log for the specified cell or value Returns Log Base 10 for the specified cell or value Returns the negative of the specified cell or value Returns the logical NOT of the specified cell or value Returns the specified cell or value rounded up to the next integer The of Decimals specifies the number of decimal places to which the original value should be rounded It must be a whole number and negative numbers are permitted to indicate places to the left of the decimal point Returns the specified cell or value rounded up when gt 5 or down Returns the sum of the defined range of cells Returns the specified cell or value truncated at the given number of decimals Examples of valid formulas SUM A1 A10 3 1415 C6 AN G A1 B1 C1 IF A1 gt 5 A1 2 A1 3 LOG A1 B1 CHAPTER 6 The SWD Collect Spreadsheet Sums the first column rows 1 through 10 PI times the value in C6 The value of cell column A this row multiplied by the v
37. alue of the cell at Column G same row Adds the first two cells and multiplies the result by the third If the contents of A1 are greater than 5 then multiply Al by 2 else multiply Al by 3 Adds the first two cells and then returns the Log Base 10 for the result Combining Expressions With Parentheses Ifa formula contains operators with the same priority the spreadsheet evaluates the operators from left to right If you want to alter the order of evaluation use parentheses to group expressions in your formula Example This formula Produces this value 4 2 4 6 2 20 4 2 4 6 2 72 81 CHAPTER 6 The SWD Collect Spreadsheet 82 Displaying Formulas on the Spreadsheet A cell containing a formula normally displays the formula s resulting value on the spreadsheet When you move the cursor over a cell containing a formula the formula is displayed in the tool tip for your reference Editing Within a Cell You can edit a cell on your spreadsheet by typing a new entry over an existing one or by editing part of the information within the cell To edit within a cell double click the cell Selecting the cell and pressing lt ESC gt will also switch to editing mode When you edit a cell containing a formula the formula is displayed and the value is hidden Changing Column Widths and Row Heights You can adjust both the column width and the row height as needed Rows automatically adjust to accommodate wrapped tex
38. am can make use of this data it must break it up into smaller usable parts That is to say the program must parse the data Through the Instrument Parser Setup you can tell the program just how to break up the block of data into smaller parts If no Parser is specified the program will not modify the data NOTE You will find it much easier to create the Parser in stages checking your work as you progress by displaying the resulting data to the screen You should first be familiar with opening your instrument and sending commands through SWD Collect so that you may check the Parsers in stages Basic Steps to Creating a Parser There are two aspects to setting up a Parser 1 You must tell the program how to recognize the data 2 You must tell the program which components of the data to save and which components to discard 43 CHAPTER 5 Setting up the Instrument Parser 44 Once the data is parsed correctly you can add Macros sequences of keystrokes and characters that are entered before or after the data Macros are often used to add extra details to the data such as the date and time or to make sure the data appears in a desired format Accessing the Parser Setup 1 Open your instrument see Quick Start Page 15 or Opening Instruments Page 29 to see what the data that is transmitted from the instrument looks like Write down some of the data you see for reference later when you must decide what type of Parser t
39. ands entered during the setup Please Note If your instrument does not require commands en sure you have correctly configured the instrument and that you are using a cable certified by the instrument manufacturer 1 Pull down the Instruments menu from the top of the screen see Figure 4 5 Page 34 and select the Command sub menu item 2 The commands that you entered for this instrument see Figure 3 5 Page 24 will appear in the Commands dialog box similar to the example shown in Figure 4 6 see Page 37 CHAPTER A Opening Instruments Commands Balance BBE Request 1 Sample Second Request 5 Samples Second e Specify Units Interrupt Cancel Figure 4 6 Commands dialog box This dialog box remains open and floats on top ofall applications You may close the Commands dialog box at any time by selecting the Cancel button 3 You may minimize the Commands dialog to a button in the Taskbar by clicking on the button with a dash in the top right corner of the Commands box 4 Please note that if you wish you may have the Commands dialog box open automatically each time you open this instrument by selecting the Options AutoOpen Commands menu item 5 Ifyou have opened an Instrument with the Keyboard destination you will be able to switch to the Destination Application using the Windows lt Alt gt lt Tab gt functionality makes this easier and the Commands dialog box will
40. at variable intervals by including specific times within the command line Repeating Commands To have the command re sent repeatedly enter a cycle time in milliseconds in square brackets at the end of the command For example suppose your instrument requires a command X to transmit each data value You could enter a cycle time of 1000 milliseconds beside the command like this X 000 Sending this command means that SWD Collect will prompt the instrument to send a data value every second until you interrupt it by clicking on the Interrupt button found on the window listing your Commands at run time or until you close the instrument Delaying Commands A time delay can be entered between commands also using square brackets Suppose your instrument will transmit the units of measurement following the command U and then requires a command X to transmit each data value You could enter the command as U 000 X and then SWD Collect will insert a 1000 milliseconds delay between each command Pacing Commands The character can also be used to pace the command Again suppose your instrument will change the units of measurement with the command C transmit the units of measurement following the command U and then requires a command X to transmit each data value You could enter the command as C U X 1000 and SWD Collect will insert a 100 milliseconds delay between e
41. ct Instruments Configure Help slala lele sl el SSS eege Figure 2 1 SWD Collect main screen Access to the program s features CHAPTER 2 Quick Start Just the Basics Configuring your Instrument The first step is to configure your instrument to work with SWD Collect 1 From the main screen pull down the Configure menu item 2 Select the Instrument sub menu item The Setup Instruments dialog box similar to the one shown in Figure 2 2 will appear Please note the listed instruments are examples only Setup Instruments pH meter Bed Remove sl Move Down iki Protocol Parser Command User Info ol Figure 2 2 Setup Instruments dialog box Setting up a New Instrument Click on the Create button You will advance to the Instrument Protocol Setup dialog box as shown in Figure 2 3 Instrument Protocol Setup Instrument Name Balance r Comm Port Pott com d Protocol None zl BaudRate 2400 zl Timeout 250 Fany None E Number of Timeouts fo Data Bits fel Sept d Ss Figure 2 3 Define the instrument protocol 10 CHAPTER 2 Quick Start Just the Basics Defining your Instrument Protocol There are some key communication parameters associated with serial RS232 communication that must be matched exactly between your instrument and the configuration in SWD Collect Jn particular if the Baud Rate Data Bits Stop Bits and Parity are not matche
42. ctions These include the cursor arrow keys lt ESC gt lt ENTER gt lt F 1 gt HOME and lt END gt These characters instead can be selected from the list of 37 Special Functions on the left side of the Define Macro dialog box see Figure 5 5 Page 59 To add one of these characters to the Macro do one of the following L Double click on the Special Function or highlight it and press lt ENTER gt You will see the selected character s appear in the Macro definition box within lt gt brackets 2 Highlight the Special Function Click on the Add Special Function button You will see the selected character s appear in the Macro definition box within lt gt brackets Ne thmariuh brntepe e vonlere et 9 Special Fp e tege Mast out some tasks including date and time stamping which will automatically insert particulars for the date and or time with the data 61 CHAPTER 5 Setting up the Instrument Parser 62 Other functions that may be inserted include 1 The Cumulative Time which records the time that has elapsed since the instrument was opened in minutes seconds or milliseconds 2 A Serial Number that assigns a unique number to each data value This numbering is continuous starting at zero when SWD Collect is first installed and increasing by one for each data value that is parsed with this Special Function 3 A Counter which simply assigns a number to each data value starting at zero each
43. culation but would still prompt the instrument 4 times at the following times past time Osec TIME TIME PAST n INTERVAL TIME 0sec 1 0 sec 0 sec 2 40 sec 40 sec 3 20 sec 60 sec 4 10 sec 70 sec Exiting the Instrument Setup At the bottom right of the Setup Instruments dialog box see Figure 3 2 Page 20 click on the OK button to return to the main SWD Collect window see Figure 3 1 Page 19 Your instruments are now configured to work with SWD Collect Proceed to Chapter 4 Opening Instruments for complete details Chapter 4 Opening Instruments Before SWD Collect can start collecting data you must first open the instrument Opening an Instrument To open an instrument do one of the following 1 From the main screen pull down the Instruments menu and select Open 2 Press lt Shift gt lt PgDn gt on the keyboard p 3 Click the special Open button from the Toolbar pictured in the margin In all cases you will advance to the Open Instrument dialog box as seen in Figure 4 1 Open Instrument pH meter Figure 4 1 Open Instrument dialog box You will see a list of the instruments that you have configured for the SWD Collect program 29 CHAPTER A Opening Instruments 30 Moving around the Open Instrument dialog box D You may scroll through the instrument names with the up and down arrow keys or you may click on the scroll bar
44. d exactly between the instrument and SWD Collect serial data transfer will not work The computer does not automatically determine what these parameters are for your instrument YOU MUST ENTER THEM HERE Specifying the Instrument Name The cursor will be flashing in the Instrument Name text box Type in the name of the instrument so that you will be able to identify the instrument throughout the SWD Collect program Do not press lt Enter gt after typing in the name as this will cause you to close the dialog box Specifying the Comport Information You must enter the correct Comport information based on the details supplied in the user manual for your instrument It is important that these details match exactly those of your instrument Note that by clicking on the arrow to the right of each box you can see a list of items from which you can make your selections Simply click on the up and down arrows to scroll through the list and click on the desired entry Port Select the port that is connected to your instrument COM2 is the default selection Baud Rate Select the Baud Rate that corresponds to the data transmission speed of your instrument 2400 is the default Baud Rate selection Parity Indicate what parity bit should be added to your data for successful communication None is the default value and this is often selected Data Bits Eight 8 appears as the default value This indicates how Word Length many bits of dat
45. data file will be opened automatically if one was specified CHAPTER A Opening Instruments In all cases you may see the data being collected immediately from the instrument and displayed in the chosen destination s or you may first have to press the Print or Send button on your instrument to actually transmit the data Opening Another Instrument If you wish to open more than one instrument simply follow the same procedure Note that any devices which are already open will not appear on the list of instruments While the procedure for configuring instruments can be followed for an indefinite number of devices SWD Collect will permit data collection from up to 9 instruments at one time provided you have up to 9 serial communications ports available Since most computers have only 2 or 4 standard COM ports additional ports must be added to your computer through an add on board The software will work with multi port boards configured to work under your operating system SWD Collecting to Other Applications The procedure for opening one or more instruments is the same The data from each instrument can be sent to any or all of the four destinations One of these destinations is named Keyboard which allows you to have data transferred to another Windows based application through the keyboard One Instrument to One Application When specifying the Keyboard destination it is necessary to follow a certain order to ensur
46. e Figure 5 1 Page 44 to see the User Prompts dialog box similar to the sample shown in Figure 5 9 User Prompt Prompt Value Batch 5 S Location P300 User Name Technician 1 H zj Figure 5 9 User Prompts dialog box On the left side are the User Prompts defined within the Macro You should enter the appropriate Prompt Value on the right side of the dialog box 1 Click on the cell that is opposite to the User Prompt 2 Click on the down arrow to reveal a list of any previously entered Prompt Values 3 Click on the appropriate value to select it 4 Ifthe appropriate response is not listed double click on the cell and type in your response to the prompt For example if the prompt asks for the Operator s Name you would enter your name CHAPTER 5_ Setting up the Instrument Parser 5 Click on the OK button to save the User Info details and you will see the Setup Instruments dialog box Figure 5 1 Page 44 again Using What We have Learned so far This Parser Setup example illustrates the use of Parsers Macros and User Prompts The example shown in Figure 5 10 could be used to add data from an instrument such as a balance into the built in QuickSheet Name Definition P 12 3 6 1 Instrument Parser Remove CM amp Lh E Macros r Discard Data Containing 1 lt Right gt lt Date gt lt Enter gt lt Left gt lt Left II Ear RB RB
47. e imported 5 Click on the OK button Viewing the Data Destination 1 Click on the open instrument to make it the active window Pull down the Options menu 3 Depending upon your selections for the Data Destination the ViewSpreadsheet and ViewMonitor options will have a check mark beside them if they were specified Clicking on these options toggles the destination on or off If you disable the destination data will not be collected there If you turn off both of these destinations the open instrument will be minimized to an icon in the SWD Collect window You must double click on the icon to maximize it Remember however that the destinations were turned off and data was not collected in them If you wish to minimize an open instrument but continue to 39 CHAPTER A Opening Instruments 40 collect data in the monitor and or spreadsheet destinations click on the button in the top left corner of the instrument window and select minimize from the sub menu This is a standard Windows feature AutoScrolling the Spreadsheet This feature is used only when the Spreadsheet is specified as a destination a Click on the open instrument to make it the active window 2 Pull down the Options menu 3 Click on the AutoScroll sub menu item to have a check mark appear beside the word AutoScroll This feature enables the spreadsheet to automatically scroll down as data is transmitted into it from
48. e the data is successfully transferred to another Windows based application A simple case of sending data from one instrument into an application can be achieved through the following steps 1 In SWD Collect open the instrument with Keyboard as one of the data destinations The specified Windows based application 35 CHAPTER A Opening Instruments 36 will be located or started according to your entries in the Instrument Data Destination dialog box see Figure 4 3 Page 31 The SWD Collect Instrument and the Destination Application will be locked together 2 Inthe Destination Application position the cursor or click on the location where the first data value is to go 3 Start sending data into SWD Collect The instrument data will be sent to the Destination Application Multiple Instruments to Multiple Applica tions A more complicated situation may arise when you would like data from more than one instrument to be sent to more than one application For example suppose you want data from two instruments to be saved in two separate Windows based spreadsheet applications To do this you simply repeat the above steps for One Instrument to One Application Sending Commands If you do not see data immediately upon opening the instrument or after transmitting the data with the instrument s Print or Send button you may need to prompt your instrument to transmit the data to the PC with one of the comm
49. e to create and specify Macros A Macro is simply a sequence of keystrokes and characters You can insert a Macro before or after each segment of data Please note that the use of Macros is optional Use them only when and where they are required As an example consider getting several weight measurements from a balance and adding these to a spreadsheet The weights can go into column A starting at Al The Parser will isolate the weight from the rest of the data sent by the balance The weight will then be sent to the cursor position in the spreadsheet so that it will be displayed in cell Al A problem occurs when the second weight arrives however It will also go into cell Al since no one has pressed lt ENTER gt to move the cursor to cell A2 The Macros are used to automatically press lt ENTER gt for you between each weight All you have to do is define one of the Macros as the lt ENTER gt key and then insert it into the Parser after the weight Such a modified Parser will then add an lt ENTER gt key to the end of each weight as it is being sent to the active Windows based application Any key or combination of keys can be specified as part of a Macro The Macro can be inserted in front of or after each segment of data Defining a Macro A Macro has to be defined in order for it to do anything in the Parser In the Parser Setup dialog box there is an area for listing Macros that are defined exclusively for that Parser These
50. enees 67 Chapter 6 The SWD Collect Spreadsheet Spreadsheet Basics cccscccseceseeeeeeeeeeeeeeeeeeeeeeseeeeeeeeneneeeeeenes 69 Using the Menu Commandes 69 Using the Toolbar Buttons ccc eeeeeeteeeereeeeeteeeeenreetenees 70 Choosing Commande ei e e S 70 Selecting Cells AA 70 Moving Around in a Spreadsheet cccecceeetteeteeeteeeees 71 Scrolling Through the Gpreadeheet 71 Loading a Spreadsheet cccccceeseeeeeeeeeeeeeeeeeeeeeteeeseeenaes 71 Saving a Spreadsheet ccceccceceeeeeeeeeeeeeeeeeeceeeseeeeneeeees 72 Formatting the Spreadsheet cecccccceeeeeeeeeeeeeseeeeteeenees 73 Making Entries in the Spreadsheet 010seeieenceeee eree 74 Displayed Value vs Stored Value 0 ecceceeeeeeteeees 74 Copying and Moving Cells in the Spreadsheet 02 75 Filling a Series Of Ces 75 Clearing the Spreadsheet seeeeeeeieeieeeeeiesineireierirrenerrene 76 Setting Fonts in a Spreadsheet cccecceesteeeeeeteeneeeees 76 Printing a Spreadsheet ccccecceeeeeceteceeeeeeeeseeeeeeeeeseeenaes 77 Defining the Print Options eceeceeseecseseeeeeneeetees 77 Previewing the Enns eege Sickening 78 Enhanced Spreadsheet Features ccsccsecesseeeeesereeeeeeeeees 79 Using Formulas to Analyze Your Data 79 Formula Operators cccceccceceeececeeeceeeeeeesseeeeneeenetenaes 79 Formula FUNCHIONS sier ekia itine re eere
51. er up to twenty commands here which you can then send to the instrument to control its operation For example your instrument may require SWD Collect to send a command of S to prompt the instrument to send data Please refer to Chapter 4 see Pages 36 to 38 for additional infor mation on sending commands 13 CHAPTER 2 Quick Start Just the Basics 14 How to Set up Commands for your Instrument l Using the mouse move the pointer to a Command box on the left side and click on it Type the required command through the keyboard It is fairly common that the command will include non printable characters such as a carriage return or line feed These should be entered as ASCII numbers enclosed in brackets For example the carriage return is 13 and the line feed is 10 A listing of ASCI numbers appears in Appendix A Click the pointer on the box beside it under the heading Description Enter a description for the command For example you could enter Start sending data as the description Please Note It is mandatory that you enter a description here for each command Complete steps 1 4 for each command that is specified in your instrument s user manual Note that when yov re actually running the instrument and choose to send commands these commands will be listed in the order they appear here from top to bottom If you would like the commands to appear in a certain order for ease
52. ered as ASCII numbers enclosed in brackets A listing of ASCII numbers appears in Appendix A Please see the section Repeating Delaying and Pacing Commands see Page 26 for further details on sending commands 3 Click the pointer on the box beside it under the heading Description 4 Enter a description for the command For example you could enter Start sending data as the description Please Note It is mandatory that you enter a description here for each command 5 Complete steps 1 4 for each command that is specified in your instrument s user manual e Double clicking on a cell will highlight any text that is present or will show the text insertion bar in an empty cell Use the scroll bar to reveal other cells e When you re actually running the instrument and choose to send commands these commands will be listed in the order they appear here from top to bottom If you would like the commands to appear in a certain order for ease of selection then ensure you enter them in order here 6 When you have finished entering the command s for the instrument click on the OK button to save the details or click on Cancel to leave the dialog box without saving any changes You will return to the Setup Instruments dialog box see Figure 3 2 Page 20 25 CHAPTER 3 Configuring Instruments 26 Repeating Delaying and Pacing Commands You are able to repeat delay pace or send commands
53. eric characters including commas and negative signs See Page 52 for examples Data is parsed based on position This can be used where the data is always in the same position See Page 53 for examples For parsing data from scales operating in continuous send mode The Scales Parser Type is specific to a particular Balance brand and model number See Pages 54 56 for examples Data is parsed based on a leading and trailing pair of delimiters The delimiter may be a comma a space ASCII 32 or any other literal character or group of charac ters See Pages 56 57 for examples Table 5 1 Parser Types Each Parser can have only one type selected Therefore the first character in a Parser must be aN C P S or a D followed by a slash Most balances and similar instruments can use a simple Numbers parser and should be fairly straightforward to work with Each Parse Type along with relevant examples is described in a corresponding section within this chapter Parser Syntax Each type of parser also has its own syntax as shown in the following N SELECTOR COMMENT C SELECTOR COMMENT P POSITIONS COMMENT S DATA FORMAT MACRO TOLERANCE COMMENT D DELIMITER SELECTOR COMMENT CHAPTER 5 Setting up the Instrument Parser The COMMENT is the only part of the Parser Syntax that is optional All other components must be specified The Parser Definition can hold up to 200 characters representing up to 500 Parser components
54. he instrument see Figure 4 3 Page 31 Simply click on the destination name to insert or remove the indicator e All destinations have access to all previously defined Parsers e You are able to specify a different Parser for each destination if necessary e At least one destination must be selected to create or modify a Parser 45 CHAPTER 5 Setting up the Instrument Parser 46 Defining a Parser Name Referring back to Figure 5 2 see Page 45 a text box is located adjacent to each destination Here is where the name of the Parser is entered 1 When creating a new Parser click in the text box to show the cursor and enter a name for it 2 When editing a Parser for an instrument that is currently open simply click on the Parser Name to highlight it 3 When editing an existing Parser for a closed instrument click on the arrow to the right of this box to reveal your list of Parsers then select the one to be changed Setting up the Parser With a Parser Name highlighted in the Instrument Parser Setup dialog box see Figure 5 2 Page 45 click on the Setup button located along the bottom of the box You will advance to the Parser Setup dialog box similar to the example shown in Figure 5 3 Name Balance Parser Spreadsheet Definition N Y 2IY 1113 Remove CR LF Manger Discard Data Containing DI 2 lt Right 3 lt Enter gt H RH Add Edit Delete Add Edit Delete
55. he list of User Prompts 4 Position the cursor in the Macro definition where you want the prompt to appear 5 Double click on the User Prompt to include it in the Macro This now allows you to click on the User Info button on the Setup Instruments dialog box see Figure 5 1 Page 44 to specify a pre set value for the User Prompts see Figure 5 9 Page 66 You must lt OK gt out of the User Prompts dialog box and repeat this procedure Oe click on the User Info button to add an additional pre set value Repeat this action for any supplementary entries When you have completed defining the Macro click on the OK button to return to the Parser Setup dialog box see Figure 5 3 Page 46 The Macro will appear on the list of Macros Adding a Macro to a Parser Macros are used by adding them to the Parser A Macro is identified by placing the Macro number inside square brackets They can then be inserted as illustrated in the following examples CHAPTER 5 Setting up the Instrument Parser Examples P 1 1 7 3 D Y 2 Y 2 P 12 15 6 6 4 5 9 D 32 5 4 IJ YNY Y N AJY 2 N 3 Y 4 The first Parser has two Macros the 1 and the 3 The Macro 1 will be added before the data 1 7 and the Macro 3 will be added at the end of the data In this example the Macro 1 could add a format character so that the data is formatted correctly The Macro 3 could be an lt ENTER gt to position the curs
56. ill automatically load this spreadsheet every time you open the instrument The AutoLoad must be switched on for each instrument that you want to have opened automatically Autoloading only supports the loading of spreadsheets in the native spreadsheet format WSP When using AutoLoad you must first click on the appropriate cell in the spreadsheet where the new data is to be entered before you start data transmission from your instrument Click AutoLoad again to turn this feature off AutoOpening the Commands 1 Click on the open instrument to make it the active window 2 Pull down the Options menu 3 Click on the AutoOpen Commands sub menu item to have a check mark appear beside the AutoOpen Commands item SWD Collect will automatically open the Commands dialog box see Figure 4 6 Page 37 for this instrument every time you open the instrument 41 CHAPTER A Opening Instruments 42 Using the Spreadsheet Menu Options Pulling down the Spreadsheet menu provides options for use with the built in spreadsheet See Chapter 6 for complete details on using the spreadsheet Using Standard Windows Options 1 Click on the open instrument to make it the active window 2 Pull down the Window menu to see the available options These are standard options within the Windows operating system Please take note of the two special toolbar buttons that produce the same results as selecting the Cascade and Tile option
57. ing the Data to a File eee ec eeceeeeeereeeteeeneeees 32 Sending the Data to an Application 0 0 32 Opening the Instrument 34 Opening Another Instrument cccesseceeseeeeeeseeeeeseeeneseees 35 SWD Collecting to Other Applications NENNEN 35 One Instrument to One Application eceeeeeeeeeteeteeees 35 Multiple Instruments to Multiple Applications 000 ee 36 Sending Commands ccccceccceeceeeneeeeeeeseeeeeeeeeeeeeeeeeeneneeeeeenenee 36 Interrupting a Commande 37 TABLE OF CONTENTS Using the Additional Options Available SEENEN 38 Viewing the User Prompts eeeeeeeeeieserirerrireeriserreeees 38 Importing a el EE 38 Viewing the Data Destination ee eeeeeeeeeeeeneeeeneees 39 AutoScrolling the Gporeadeheet e 40 AutoStarting your Instrument 0 0 2 cceeeeceteceeeeeeeeeteeeeeeeeeees 40 AutoLoading a Gpresadeheet 41 AutoOpening the Commandes 41 Using the Spreadsheet Menu Opttons 42 Using Standard Windows Options e eeeeeeeeeeeeeee eee 42 Closing all Open Instruments ccceceeeteeeteeeteeeeeeeeteeees 42 Closing the Instrument ccccceseeeseeeeeeeeeeeeeeeeeeneeeeneeseeeeeneeeaes 42 Chapter 5 Setting up the Instrument Parser Basic Steps to Creating a Parser c ccssccseceseeeeeeeeeeeeeeeeeees 43 Accessing the Parser Setup 0 cccecceceeeeseesereeeeeeeeeeeeees 44 Defining a Destination for Incoming Data 00 45 Defini
58. ize the data in the specified destination see Page 58 For example between each selector in the above Numbers Parser you might place a Macro to press the lt Enter gt key so that each number appears on a new line Using the Position Parser Type Many instruments generate data that is always in the same position For example a balance may always have the weight in positions to 7 and the unit always in positions 9 10 If the data is always in the same position a Parser Type of Position P can be used The following is the syntax for such a parser setup P POSITIONS COMMENT This Parser consists of a P followed by a This is followed by the positions that are to be saved The Position is a sequence of number ranges separated by commas Example 1 P 1 7 comment Suppose that you collect the following data from your balance 0193 67 mg The example Parser P 1 7 comment will extract data in positions to 7 Example 2 P 12 15 6 6 5 9 Comment Now suppose that you collect the following data from your instrument READ4T mg 23 5 The positions indicated in the above Parser are 12 to 15 6 to 6 and 5 to 9 The numbers here represent the positions in the data string that contain 53 CHAPTER 5 Setting up the Instrument Parser 54 the required values Each sequence must state a start and end position In the example the first data value consists of characters in positions 12 to 15 inclusive 23 5 The second dat
59. l numbers are shown here 33 21h 76 4Ch L 119 77h w 34 22h i Kit 4Dh M 120 78h x 35 23h 78 4Eh N 121 79h y 36 24h 79 4Fh O 122 7Ah Z 37 25h 80 50h P 123 7Bh 38 26h amp 81 51h Q 124 7Ch 39 27h i 82 52h R 125 7Dh 40 28h 83 53h S 126 7Eh 41 29h 84 54h T 127 7Fh 42 2Ah 85 55h U 128 80h 43 2Bh 86 56h vV 129 SIb 44 2Ch 87 57h W 130 82h 45 2Dh 88 58h x 131 83h a 46 2Eh y 89 59h Y 132 84h 47 2Fh 90 5Ah Z 133 85h 48 30h 0 91 5Bh 134 86h 49 31h 1 92 5Ch 135 87h 50 32h 2 93 5Dh 136 88h 51 33h 3 94 5Eh A 137 89h 52 34h 4 95 5Fh 138 8Ah 53 35h 5 96 60h 5 139 8Bh 54 36h 6 97 6lh a 140 8Ch ji 55 37h 7 98 62h b 141 8Dh i 56 38h 8 99 63h c 142 8Eh 57 39h 9 100 64h d 143 8Fh A 58 3Ah i 101 65h e 144 90h 59 3Bh R 102 66h f 145 91ih 60 3Ch lt 103 67h g 146 92h 61 3Dh 104 68h h 147 93h 62 3Eh gt 105 69h i 148 94h 6 63 3Fh 106 6Ah j 149 95h 64 40h 107 6Bh k 150 96h 65 41h A 108 6Ch 1 151 97h 66 42h B 109 6Dh m 152 98h y 67 43h C 110 6Eh n 153 99h 68 44h D 111 6Fh o 154 9Ah U 69 45h E 112 70h p 155 9Bh 70 46h F 113 71h q 156 9Ch 71 47h G 114 72h r 157 9Dh 72 48h H 115 73h s 158 9Eh 73 49h I 116 74h t 159 9Fh f 74 4Ah J 117 75h u 160 AOh a 75 4Bh K 118 76h v 161 Alh 84 ASCII HEX Char 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 1
60. le when nothing is being weighed When you do put something on the scale SWD Collect will wait for the first stable reading above 0 35 and then keep it Thirdly SWD Collect looks for the next stable value within the range set by the tolerance level that you specify While it won t keep this value the program will recognize that the scale has returned to zero and will begin again at step 1 So if you set the tolerance level at 0 35 the next stable value within the range 0 35 to 0 35 will be recognized but not kept The following is an example of a Scales Parser setup 55 CHAPTER 5 Setting up the Instrument Parser 56 Example 1 1 2 0 35 Macro I lt Header gt lt Right gt lt Data gt lt Right gt lt Units gt 2 lt Enter gt Please note the tolerance level of 0 35 as the last component of the Parser You will also notice that the Macros 1 and 2 are included in the Parser Please refer to the section on Using Macros for further details on creating Macros and adding them to a Parser The lt Header gt lt Data gt and lt Units gt components of Macro 1 are selected from the list of Special Functions at the bottom in the Define Macro dialog box These will extract the header HH weight reading data and units UUU respectively Once SWD Collect has determined a stable value is to be kept this Macro will extract the necessary details from the data string You must at least i
61. lect will then prompt the instrument n times The program will do this at the following time intervals past time Osec when the command is first sent and then SWD Collect will stop TIME TIME PAST n CALCULATION INTERVAL TIME 0sec 1 10000 10 sec 10 sec 2 10000 x 1 10 sec 20 sec 3 10000 x 1x1 10 sec 30 sec 50 10000 x 1x1x1 etc 10 sec 500 sec Please note that the n 50 means the number of time intervals and not the value of the power integer itself 27 CHAPTER 3 Configuring Instruments 28 Suppose you require data from your instrument more frequently at first but then less often as time progresses You could specify a time interval command where the START TIME is 10 seconds 10000 msec after the command is first sent and with a MULTIPLICATION FACTOR of 2 to be raised to the power of n 4 times The command would be X 10000 2 4 The program will prompt the instrument 4 times at the following time intervals past time 0sec TIME TIME PAST n CALCULATION INTERVAL TIME 0sec 1 10000 10 sec 10 sec 2 10000 x 2 20 sec 20 sec 3 10000 x 2x2 40 sec 40 sec 4 10000 x 2x2x2 80 sec 80 sec Example 3 To send the same sequence as above but in reverse order specify the nas 4 You may want to use this if the instrument s data is required more frequently as time goes on The command would be X 10000 2 4 In this case the program uses a slightly different cal
62. les S Rhioox GB close Figure 6 5 Print Preview dialog box 78 CHAPTER 6 The SWD Collect Spreadsheet Enhanced Spreadsheet Features Using Formulas to Analyze Your Data Using a formula can help you analyze data on a spreadsheet With a formula you can perform operations such as addition multiplication and comparison on spreadsheet values Use a formula when you want to enter calculated values on a spreadsheet e A formula always begins with an equal sign e A constant is a numeric or text value that you type directly into a cell A simple formula combines constant values with operators such as a plus or minus sign in a cell to produce a new value from existing values Think of a formula as one side of an equation whose result is shown in the cell The following is an example of a formula B4 25 100 Formula Operators Valid operators in a formula are Addition Subtraction Power operator Multiplication Division Logical And Logical Or Negation Greater Than Less Than Equality Sum a range of cells lL AY eS eS S21 CHAPTER 6 The SWD Collect Spreadsheet 80 Formula Functions Valid functions in a formula are ABS Coord or Value ADD a b EXP Coord or Value IF a b c ISEMPTY Coord LN Coord or Value LOG Coord or Value NEG Coord or Value NOT Coord or Value ROUND UP Coord or Value of Decimals ROUND Coord or V
63. ls from a list Text Allows you to specify that the entry in a cell is Text Float Allows you to specify that the entry in a cell is Float 73 CHAPTER 6 The SWD Collect Spreadsheet 74 Making Entries in the Spreadsheet There are two basic kinds of entries in a spreadsheet constant values and formulas When a cell is highlighted you can make any type of entry in it A constant value is data that you type directly into a cell It can be a numeric value called Float Real Numbers or Integers or it can be Text such as a date time currency or percentage Constant values do not change unless you select the cell and edit the value yourself As you make your entry the program will automatically determine if it is either a Text type or Float type entry e If you enter numbers with or without decimal places it will be considered a Float type entry e If you type any characters other than numbers in a cell it will automatically be a Text type entry A formula is a sequence of values cell references names functions or operators that produces a new value from existing values Formulas always begin with an equal sign and the program recognizes automatically when a formula is entered A value that is produced as the result of a formula can change when other values in the spreadsheet change To change the type of entry follow these steps Select the cell or range of cells to be changed Pull down the Spreadsheet
64. lt END gt in the current row to the last column containing data lt CTRL gt lt HOME gt to the top left corner of the spreadsheet lt CTRL gt lt END gt to the bottom row of the last column containing data in the spreadsheet lt TAB gt to the next cell in the same row lt Shift gt lt TAB gt to the previous cell in the same row Scrolling Through the Spreadsheet Action Move the pointer to the down arrow in the vertical scroll bar on the right edge of the window and then click the right mouse button Result The spreadsheet scrolls down one row Action Click the scroll bar area below the scroll box Result The spreadsheet scrolls down one screen Action Move the pointer into the scroll box Hold the mouse button down move the pointer back to the top of the vertical scroll bar and then release the mouse button This is called dragging Result The spreadsheet scrolls back up to the first row Loading a Spreadsheet To load a spreadsheet that you have previously saved do one of the following 1 Pull down the Spreadsheet Menu 2 Select Load 1 Click on the Load button shown in the margin H CHAPTER 6 The SWD Collect Spreadsheet 72 In either case you will advance to the Load Spreadsheet dialog box similar to the example shown in Figure 6 1 Load Spreadsheet 2x Look in Scot Si c Fiename Files of type Spreadsheet WSP zl Cancel Figure 6 1 Specify the file to load
65. ly to the keyboard for entry in another Windows based application By sending the data to the keyboard SWD Collect fools any other application running in the foreground into thinking that you are manually entering the data For example you can use your favorite spreadsheet while SWD Collect is collecting data in the background Whenever data becomes available it will be sent to the keyboard resulting in the data being added to the spreadsheet in real time CHAPTER 1 Introduction to SWD Collect When selecting destinations other than the keyboard SWD Collect works in the background of the computer This is done in such a way that it will not interfere with other programs running on the computer at the same time SWD Collect will permit data collection from up to 9 instruments at one time Most computers can support up to 4 standard RS232 COM ports and these can be located on the mother board or an add on board The software will work with multi port boards configured to work under your operating system Conventions in this Manual The following conventions are used in this manual e The word press is used for keys you press e The word type is used when asking you to type a response through the keyboard e The word click is used when asking you to respond with the mouse e Dialog boxes have special command buttons and these are shown in Bold Italic print when referenced e Special keyboard keys
66. menu Select the Format sub menu Make your selection from either Text or Float PWNS Displayed Value vs Stored Value The number you see in a cell is based on the cell number format and may differ from the number stored For example ifa cell is formatted to display only two decimal places and you type 26 006 in that cell the spreadsheet displays 26 01 The stored number is used for calculations no matter how it is displayed on the screen CHAPTER 6 The SWD Collect Spreadsheet To see the stored number in a cell double click on that cell The stored number will be shown highlighted Copying and Moving Cells in the Spreadsheet 1 Pull down the Spreadsheet menu 2 Select Edit A list of sub menu items becomes available Please Note Before using any of the sub menu options select the cells that will be affected by the menu option Copying and moving cells can be performed by a combination of the Cut Copy and Paste sub menu options Menu Option Description Cut Removes the selected characters from the cell and places them on the Clipboard Pressing lt Shift gt lt Delete gt will also perform this function Copy Makes a copy of the selected characters and places them on the Clipboard Pressing lt Crtl gt lt Insert gt will also perform this function Paste Places the contents of the Clipboard in a cell at the insertion point Pressing lt Shift gt lt Insert gt will also perform this function Filling a Series
67. nclude one Macro that includes the lt Data gt Special Function in order to extract a weight reading Using the Delimiter Parser Type If none of the above Parser Types are suitable for the data from your instrument you may need to use the Delimiter Type D A DELIMITER is a computer term for any character that separates units of data The comma and the space are common delimiters Look at the data and see if some unique characters can be found between the data that is required These could be any characters except the forward slash The comma and the space are common separators but even words can be used provided that none of the letters in the word are also part of the required data The following is the syntax for such a parser setup D DELIMITER SELECTOR COMMENT The D Parser consists of a list of the valid delimiters followed by a list of Y s and N s selectors to indicate the data that is to be saved In CHAPTER 5 Setting up the Instrument Parser this case the data will be whatever string of characters appears Example Di 32 YNNNYNYN COMMENT In this example the delimiters are a space ASCII 32 and a comma If either of these characters are encountered in the data string the program knows that one segment of data ends and another one starts Suppose your instrument transmits a string of data as follows 23 5 units 0 7 units 27 6 units 25 6 units The Delimiter Parser D 32 YNNNYNYN COMMENT
68. ng a Parser Name 46 Setting up the Parser ecceeeceeseeeeeeeeeeeeeeeeeeeecteeeeeeeeeeeses 46 Specifying the Parser cccceeeseeesseeeeeneeeeseeeesaeees 47 Removing Carriage Return or Line Feed from Data 47 Defining Macros cccceecceeeceeeeeeeeeeeeteeeeeeeseeseaeenneeenaes 47 Discarding Data using Identifiers 0 00 ees 47 Designing a Passel ec eeecceseeeeeeeeeeeenteereneeeseneeesentereneeees 49 Parser TYPE Srii onetati Re eee 49 Tips to follow when trying to designing a suitable Parser 49 Parser Syntaks dees eee i ui aa 50 Choosing a Suitable Parser Type cccceeseeceteeeteeeteeeees 52 Using the Numbers Parser Type scce 52 Using the Position Parser Type ccecce 53 Using the Scales Parser Type ccesceeeteeteeereeenees 54 Using the Delimiter Parser Type o c 56 USING MA S a ance cen Faekicecvescesetane Eed SEN 58 Defining a Macro eeeceeececeeeeeeeeeeeeeeeeeeeneeceeeeeeesneeeeteeeeeeenaes 58 Including Keyboard Characters in the Macro 60 Including Special Functions in the Macro 61 iii TABLE OF CONTENTS Including ASCII Characters in the Macro 63 Including User Prompts in the Macro 63 Adding a Macro to a Parser 00 eeeceeeceeeseeeeeeneerenteeenneees 64 Removing Macros from a Parser n 65 Displaying the User Prompts cccccsseesssereesseeeeneseeeeeeseeeeseees 66 Using What We have Learned So far ssecceseeeeeesereeeeeee
69. o use Also you should consult the User Manual for your instrument to determine if the data is transmitted in a set format Then Close the instrument 2 Pull down the Configure Menu and select Instrument to open the Setup Instruments dialog box as seen in Figure 5 1 Setup Instruments pH meter Create Remove Move Up tha Move Down Protocol Parser Command User Info iki Figure 5 1 Setup Instruments dialog box 3 Highlight your instrument s name by clicking on it 4 Click on the Parser button to set up a parser for the selected instrument The Instrument Parser Setup dialog box will open similar to the example shown in Figure 5 2 see Page 45 CHAPTER 5_ Setting up the Instrument Parser Instrument Parser Setup Destination Parser Name I File Ir d I Keyboard e IV Spreadsheet Balance Parser Spreadsheet M Monitor Is Setup Delete Cancel Figure 5 2 Instrument Parser Setup dialog box Defining a Destination for Incoming Data There are four possible destinations for incoming data File Spreadsheet Keyboard Monitor Each is marked along the left side of the Instrument Parser Setup dialog box seen in Figure 5 2 Supplementary Notes on Defining a Destination e An indicator appears in the check box beside each destination name when you select it e You can select the destination either here or in the Instrument Data Destination dialog box when you actually open t
70. opied in whole or in part without written consent except to make a backup copy for normal use License Labtronics Inc grants you a non exclusive license to use SWD Collect on a single machine and to copy it for a backup in support of your use of the program on a single machine Chapter 2 Quick Start Just the Basics The purpose of this Chapter is to introduce you to the SWD Collect environment Following this chapter will show you how to quickly configure one of your instruments and then see the program collect raw data from that instrument Comprehensive details of the SWD Collect software are provided in Chapters 3 4 5 and 6 for your reference You should first be familiar with your Windows operating system and you should know how to use the mouse to click and drag the pull down menus as well as select options More importantly you should first have your instrument connected to a COM port on the back of your computer and you should be able to provide the comport details that must be entered in SWD Collect If you have not yet installed SWD Collect onto your computer go back to the Installation section now Pages 6 to 8 and follow the required steps Once installed you are ready to start the program Start SWD Collect from Windows by selecting the program icon from Start Programs SWD Collect V4 0 Upon entering the program you will see the SWD Collect main screen as shown in Figure 2 1 Ej swo Colle
71. or on the next line ready for the next data point Macros can be used as frequently as required and the same Macro can be used several times as illustrated in the second Parser example This example could also be rewritten as D 2 Y 2 Several Macros can also be linked together forming one large Macro as shown in the fourth example The 5 4 1 acts as one large Macro since the program will perform one after the other Removing Macros from a Parser From the Parser Setup dialog box see Figure 5 3 Page 46 position the cursor before the Macro in the Definition text box and press the lt Delete gt key to delete the square brackets as well as the Macro number To delete the contents of an established Macro highlight it and click on the Delete button Note that the number reference of the Macro remains displayed 65 CHAPTER 5 Setting up the Instrument Parser 66 Displaying the User Prompts In the Setup Instruments dialog box you will see the User Info button The User Info button will reveal a list of User Prompts only if you have specified a Parser that includes User Prompts asking the operator to enter information Selecting this button allows you to enter Prompt Values for responding to the user prompts when the instrument is opened Once you have created a Parser for the instrument that includes User Prompts you can click on the User Info button in the Setup Instruments dialog box se
72. ort Information Enter the correct Comport information based on the details supplied in the user manual for your instrument It is important that these details match exactly those of your instrument Note that by clicking on the arrow to the right of each box you can see a list of items from which you can make your selections Simply click on the up and down arrows to scroll through the list and click on the desired entry Port Select the port that is connected to your instrument COM2 is the default selection Baud Rate Select the Baud Rate that corresponds to the data transmission speed of your instrument 2400 is the default Baud Rate selection Parity Indicate what parity bit should be added to your data for successful communication None is the default value and this is often selected Data Bits Eight 8 appears as the default value This indicates how Word Length many bits of data are in a data unit for communication purposes Stop Bits Indicate how many stop bits are added to the data unit The default selection is 1 21 CHAPTER 3 Configuring Instruments 22 Defining a Protocol for Data Transmission The Protocol is also known as handshaking which establishes the method for controlling the flow of data between devices so that one device transmits only when the other device is ready SWD Collect is designed to be ready for your device s transmission at all times so you need only select the default pro
73. ouble clicking the mouse This means to position the arrow cursor on the item to be selected and then push the left mouse button twice in rapid succession CHAPTER 1 Introduction to SWD Collect On Line Help The On Line Help is a Windows Help file allowing you to choose subjects relevant to the program When you choose Help from the menu bar the Help window will open on the screen If you are unfamiliar with using a windows help file you can obtain instructions from the Help program s menu item Help How to Use Help Status Line and Tool Tips Help At the bottom of the SWD Collect screen is a status line that shows messages to help you use the program It lets you know what a certain menu option will do by displaying a message as you position the mouse pointer on it For example if you pull down the Configure Menu and position the pointer over Instrument Setup an Instrument is the message that appears on the status line The status line also lets you know which open instrument is the active window as well as what port the instrument is connected to To get help with a toolbar button point to it rest the mouse pointer on the button A tool tip will appear with a brief description of the button s function Exiting from SWD Collect To exit from the SWD Collect program pull down the Instruments Menu and choose Exit Last Minute Changes From time to time improvements are made to both the software and the manual
74. out Defining Macros When defining a Parser you are able to create and specify Macros A Macro is simply a sequence of keystrokes and characters You can insert a Macro before or after each segment of data Please refer to the section Using Macros later in this chapter see Page 58 It is also a good idea to complete the Parser first and then add the Macros one at a time Discarding Data using Identifiers This feature gives the ability to ignore certain data that contain strings sent from the instrument For example some instruments such as a balance will send special characters like T or TA along with a data 47 CHAPTER 5 Setting up the Instrument Parser 48 value when being tarred While a Parser Definition can be set up to isolate only numeric values it won t make judgments based on accompanying characters and therefore the tare value would be treated as any other But by telling SWD Collect to discard data containing the string T or TA the decision is made by the Parser before the data can be isolated The key here is to know what strings are sent with the data from your instrument The User s Manual for your instrument should help you determine these If you know that certain strings consistently accompany the data you don t want to keep you can specify these as identifiers for discarding data 1 Click on the Add button located at the bottom of the area called Discard Da
75. r selections 69 CHAPTER 6 The SWD Collect Spreadsheet Using the Toolbar Buttons To choose a toolbar button click it Using these buttons requires a mouse Placing the mouse cursor on a toolbar button will cause the program to display a help line at the bottom of the window which explains the function of the toolbar Choosing Commands There is usually more than one method to achieve the same result For example there are several equivalent ways to copy data Choose the method that suits you best Remember you must select the cells or objects you want to work with before choosing most commands Selecting Cells Selections are always rectangular blocks of cells To select Do the following A single cell Click on it The cell will be highlighted with a heavy border A range of cells Position the mouse pointer over the first cell then hold down the left mouse button and drag diagonally from the first cell to the last cell Re lease the mouse button and the range will be highlighted An entire row Click the row heading An entire column Click the column heading The entire spreadsheet Click on the square button that is above row 1 and to the left of column A 70 g CHAPTER 6 The SWD Collect Spreadsheet Moving Around in a Spreadsheet Use To Move Arrow keys up down left right one cell lt PAGE UP gt or up or down one window lt PAGE DOWN gt lt HOME gt to the beginning of the current row
76. red but the data does not make sense There are some key communication parameters associated with serial RS232 communication that must be matched exactly between your instrument and the configuration in SWD Collect In particular if the Baud Rate Data Bits Stop Bits and Parity are not matched exactly between the instrument and SWD Collect serial data transfer will not work The computer does not automatically determine what these parameters are for your instrument YOU MUST ENTER THEM IN THE SOFTWARE 3 The cable between the instrument and the computer may be incorrect This will usually result in no data being received Try a different cable and confirm that the wiring is correct by contacting the instrument manufacturer 4 The computer hardware especially the RS232 port may not be working Check the Comport configuration in your operating system or try a different COM port preferably on a different computer 87 APPENDIX B Troubleshooting 5 The instrument may not be sending the data The instrument may need to be set up differently or its RS232 port is not functional Try a different instrument the simpler the better to confirm that the computer end is working properly 88 Index Symbols lt Data gt 56 lt Header gt 56 lt Units gt 56 A ASCII numbers 14 25 83 autoload 41 automatic focus locking 32 autoopen commands 37 41 autoscroll 40 autostart 40 Cc clear 79 close all 42 close instrument
77. rument Protocol Setup eeee 12 Defining Instrument Commands cceeceeeeeeeeeeeeeneeeeeneeeenees 13 How to Set up Commands for your Instrument 14 TABLE OF CONTENTS ii Opening the Instrument s cceceseeeeeeeeeeeseeeeeseeeeeseeeneseeeees 15 Where to Send the Instrument Data 16 Sending Commands ccccesceceeeeeeeeeeeeeeeeeeeeeeseneesneeeeeeeseeeeeeeennes 17 Closing the Instrument c cccseceeeeeeseeeeeeeeeneeeeeeeeeeeeeeeeeeeeeanes 18 Chapter 3 Configuring Instruments Setting up a New Instrument ccc cceeseceeeeeeeeeeeeeeeeseeeeeeeeeens 19 Defining your Instrument Protocol ccccceeceeeeteeeteeees 20 Defining Instrument Commands cceeceseeeeeeeeeeeeeeeeeeeeenes 24 How to Set Up Commandes 25 Repeating Delaying and Pacing Commandes 26 Repeating Commande s seieeeeeeeeeieeieeierierirerrsrrerenees 26 Delaying Commande sesseseieeieeieeieeeieietintertinreneenene 26 Pacing Commande 26 Sending Commands at Specified Intervals 0 26 Exiting the Instrument Setup ceeceeeeeeeeeeeeeeeeeeeteeeeeeenes 28 Chapter 4 Opening Instruments Opening an Instrument cceeeeceeeseeeeeeeeeeeseeeenseeeeeeseeeeeseeens 29 Specifying the User Info ccecccccccceceeeeeeeseeeeeseeeeesneeeenaes 30 Moving around the Open Instrument dialog box 30 Where to send the Instrument Data 31 Send
78. s Closing all Open Instruments 1 Click on the open instrument to make it the active window 2 Pull down the Window menu 3 From here select the Close All sub menu item All the open instruments will be closed if you select this option You will see a dialog box asking you to confirm closing each instrument Closing the Instrument Data will be received and collected until you close an instrument To do this click on the open instrument to make it the active window then pull down the Instruments menu bar and select Close or click on the Close button from the toolbar You may also press lt SHIFT gt lt PgUp gt The system will open a dialog box asking you to confirm closing the instrument Click the OK button to close the instrument or click the Cancel button to continue collecting data with the open instrument Chapter 5 Setting up the Instrument Parser In programming language the term to parse means to break up a long string of data into individual data segments SWD Collect will receive data until the specified Number of Timeouts occur You indicate the Timeout duration and the Number of Timeouts in the Instrument Configuration described in Chapter 3 see Figure 3 3 Page 20 At this point the program will have a block of data from the instrument in memory This block could be as simple as one number or it could be many numbers and characters spread over several lines Before the progr
79. smitted The SWD Collect Spreadsheet Chapter One of the possible destinations for data that is collected is the built in spreadsheet known as the QuickSheet This chapter can be read as a separate reference for using the Spreadsheet Spreadsheet Basics When opening an instrument select Spreadsheet as one of the destinations SWD Collect will open a new spreadsheet and the data from your instrument can be entered directly into it You may save the data within the spreadsheet as a separate spreadsheet file which you may also open at another time to add more data to it Please read this Chapter for complete details The spreadsheet is a grid of 400 rows and 26 columns Each cell is the intersection of a row and a column and it has a unique address or reference For example the cell where column B and row 5 intersect is cell B5 You use cell references when you write formulas or refer to cells Generally you first select the cell or cells you want to work with and then you enter data or choose a command Selected cells appear highlighted on your screen The active cell is the cell in which data is entered when you start typing Only one cell is active at a time The active cell is shown by a heavy border Using the Menu Commands Menu commands pertaining to the Spreadsheet are grouped into the Spreadsheet Menu on the menu bar across the top Pull down this menu to see the available menu options and to make you
80. strument Setups Parsers Macros or data are included for demonstration purposes only When the program has a default value it will be referenced Special Keys and Procedures Certain keys combinations and procedures give consistent behaviors when using Windows based applications The following are just a few to note lt Alt gt lt Tab gt When running any Windows based program you can press lt Alt gt lt Tab gt to switch to another program which is already running The program you were using will continue to operate in the background The OK and Cancel Buttons Many of the Dialog Boxes used in the program contain both an OK button and a Cancel button Selecting the OK button will accept any input you provided in the Dialog Box and then close the Box Selecting the Cancel button will ignore any input you provided and close the Dialog Box Words With An Underlined Letter Many menu options and button labels will contain a letter which is underlined This indicates that the letter is a hot key Generally speaking pressing lt Alt gt in combination with a hot key is equivalent to clicking on the selection CHAPTER 1 Introduction to SWD Collect For a Menu from the Menu bar you can type Alt plus the hot key For example the Instruments Menu has an underlined I Instead of using the mouse you could press lt Alt gt lt I gt or lt Alt gt then lt I gt For an option from a Menu
81. such as Shift Alt Ctrl ESCape Tab INSert DELete etc will be enclosed in triangular brackets For example lt INSert gt lt DELete gt lt TAB gt lt SHIFT gt lt ALT gt etc e Two keys in a row without a space such as lt CTRL gt lt INSert gt means press and hold down the lt CTRL gt key while pressing lt INSert gt e Computer input such as file names are specified within double quotes in the manual Do not include the quotation marks when entering the input For example if a setup is included in the manual to explain how to enter a file name you would not enter the quotation marks e Menu selections are referenced in bold print with the hot key character for the selection underlined For example when a menu option must be chosen the manual will say something such as Pull down the Configure Menu and select Instrument To do this you would click on the Configure menu option and then select the Instrument option from the sub menu which appears when you select Configure CHAPTER 1 Introduction to SWD Collect e Proper names used in the program are denoted by a leading capital letter for example Instrument Data Destination or Parser Setup e Aninstrument refers to any external device other than the computer This manual assumes you know the theory and principles of the laboratory instruments being used and their resultant data e Dialog boxes are shown for your reference However any examples of In
82. t or the largest font entered into the row In a new spreadsheet all the columns are set to the standard width You can change the standard width setting to adjust all columns on the sheet or you can adjust only the columns you want to change These changes are performed by placing the cursor between two rows or two column headings until it changes to a double arrow and then hold down the left mouse button and drag the line to its new location Appendix A ASCII Numbers If your data is delimited by a particular keyboard printable character you can type it directly into the parser However if the delimiter is non printable you must enter the appropriate ASCII number within brackets The hexadecimal equivalents HEX are also shown ASCII HEX Common Delimiters Control Character 0 00h null NUL 1 Olh SOH 2 02h STX 3 03h ETX 4 04h EOT 5 05h ENQ 6 06h ACK 7 07h beep BEL 8 08h backspace BS 9 09h tab HT 10 0Ah line feed LF 11 OBh home hard return VT 12 0Ch form feed page break FF 13 0Dh carriage return CR 14 OEh page column break SO 15 OFh SI 16 10h DLE 17 llh DC1 18 12h DC2 19 13h DC3 20 14h paragraph marker 1 DC4 21 15h NAK 22 16h SYN 23 17h ETB 24 18h CAN 25 19h EM 26 1Ah SUB 27 1Bh ESC 28 1Ch cursor right FS 29 1Dh cursor left GS 30 1Eh cursor up RS 31 1Fh cursor down US 32 20h space APPENDIX A ASCII Numbers For your reference additional ASCII and hexadecima
83. ta Containing You ll see the Discard dialog box see Figure 5 4 prompting you to Enter the discardable data identifier text Enter the discardable data identifier text aa Cancel Figure 5 4 Enter the discardable data identifier text 2 Type in the text up to 64 characters that accompanies the data you want discarded This entry is case sensitive 3 Click on the OK button to save this string and it will be added to the list of identifiers You may Add as many identifiers as necessary but the more you add the slower the parser will be Each identifier must be entered separately You may also Edit or Delete entries CHAPTER 5 Setting up the Instrument Parser Designing a Parser When determining a parser solution for your data it is best to first collect the instrument s raw data This means collecting data without the use of any parser following the procedures described in chapters 2 and 3 of this manual Once you carefully examine the data in its raw format a parser can easily be designed to handle the data Tips to follow when trying to designing a suitable Parser 1 Make your Parser in stages After each change you make to the Parser save the new configuration by clicking on the OK button in the Instrument Parser Setup dialog box see Figure 5 2 Page 45 2 Click the OK button in the Setup Instruments dialog box see Figure 5 1 Page 44 to make your open instrument
84. tination File dialog box as illustrated in Figure 4 4 Destination File Look in CH Collect z fal ol Files of type Data Files DAT x Cancel Help Figure 4 4 Destination File dialog box Specify the required information for the file destination then click on the OK button You will return to the Instrument Data Destination dialog box see Figure 4 3 Page 31 Sending the Data to an Application When Keyboard Application is selected the data is entered directly into the Windows based application that you specify here such as your own spreadsheet program The Command Line and Data File fields will default whatever entries were made there previously for that instrument This section allows you to take advantage of the Automatic Focus Locking feature of SWD Collect where the Instrument and another application are locked together If no entries are made for these fields then the program will send the instrument data through the keyboard into whatever application that is the window of focus identified as the one with the highlighted title bar This occurs with the first measurement after which SWD Collect is locked to the application CHAPTER A Opening Instruments Specifying a Command Line to run the Destination Application Enter the command line to run the desired destination application The Instrument and the application will then be locked together so that data
85. to the Macro For example you will see lt Alt F7 gt As described certain keys such as the lt Alt gt key will appear in the Macro Keys dialog box only if they are combined with a second one However the second component will occasionally get lost during parsing For example clicking on the lt Alt gt key and the lt F gt key will insert the combination lt Alt F gt in the Key box But in this case the F will occasionally be lost when the data is parsed and the macro is applied CHAPTER 5 Setting up the Instrument Parser To be certain that this second component does not get lost please follow these steps a Goto the new macro keys that have been added to the macro For example go to the lt Alt F gt b Delete the second component by placing the cursor before it and pressing the lt Delete gt key For the lt Alt F gt example you would place the vertical cursor immediately left of the F and press the lt Delete gt key once c Ensure that you leave a space between the first component and the right gt bracket For example lt Alt gt and NOT lt Alt gt d Re type the deleted second component immediately to the right of the gt bracket For example lt Alt gt F This correction will ensure that the macro works properly Including Special Functions in the Macro Certain Keyboard Characters cannot actually be typed into the Macro because they control the cursor and other fun
86. tocol NONE Any additional protocols that may be listed are custom designed methods reserved for highly specialized applications Specifying a Timeout for Data SWD Collection When the program detects data arriving at the comport it starts an internal clock and will collect data until an interval of time occurs when no more data is received This time interval is known as the Timeout After the Timeout occurs the program will organize parse the data and send it where you specify the keyboard a spreadsheet the monitor or to a specified file SWD Collect then gets ready to receive the next segment of data A Timeout that is too short will result in data being chopped up into small segments A Timeout that is too large will result in long delays between receiving the data and seeing the data at the specified destination An overly large Timeout also can result in missing data Click on the arrow to the right of the Timeout box The Timeout in milliseconds can be specified by scrolling through the list of available times and selecting one or you may specify a timeout value that is not listed by clicking in the text box and typing in the desired time in milliseconds The default Timeout value of 250 milliseconds will work for most data collection Leave this default setting unless you are certain that your instrument s timing will require a different value Defining the Number of Timeouts for Data SWD Collection Here you may specif
87. uired steps Once you have installed SWD Collect onto your computer you are ready to start the program Start SWD Collect from Windows by selecting the program icon from Start Programs SWD Collect V4 0 Upon entering the program you will see the main SWD Collect screen shown in Figure 3 1 Ej SWD Collect Configwe Help Sst CIS tlele F el Figure 3 1 SWD Collect main screen Access to the program s features Setting up a New Instrument Your first task is to configure your instruments to work with SWD Collect 19 CHAPTER 3 Configuring Instruments 1 From the main screen pull down the Configure menu 2 Select the Instrument sub menu item The Setup Instruments dialog box will appear similar to the sample shown in Figure 3 2 Setup Instruments Click on the Create button to Create set up a new instrument pH meter Remove instruments from the list with the Remove button Remove Revise the order of instruments on the list a Move Down Specify User Info details linked to User Prompts Set up Commands to send to the instrument Set up Parsers for the instrument Click on the Protocol button to advance to the Instrument Protocol Setup Command User Info Parser Figure 3 2 Setup Instruments dialog box Here you are able to create and update the configuration for each instrument connected to SWD Collect If you have already
88. ure 3 3 Page 20 23 CHAPTER 3 Configuring Instruments 24 Defining Instrument Commands Does your instrument require a command from the computer to prompt it to start or stop transmitting data Check your instrument s manual for a section on External Control 1 Ifyour instrument does require such commands proceed through the following instructions 2 Ifyour instrument does not require a command from the computer skip ahead to Chapter 4 Opening Instruments If your instrument does require one or more commands from the computer click on the Command button along the bottom of the Setup Instruments dialog box to open the Instrument Command Setup dialog box as seen in Figure 3 5 Instrument Command Setup Command Description 1 32 Request a Reading 2 32 1000 Request 1 Sample Second 3 32 200 Request 5 Samples Second 4 JU Specify Units 5 Ch Change Units 6 Figure 3 5 Instrument Command Setup dialog box You can enter up to twenty commands here which you then can send to the instrument to control its operation Please refer to section Sending Commands in Chapter 4 see Page 36 for more complete details CHAPTER 3 Configuring Instruments How to Set Up Commands 1 With the mouse move the pointer to a Command box on the left side and click on it 2 Type the required command through the keyboard Non printable characters such as a carriage return should be ent
89. w monitor 39 view spreadsheet 39 other applications 35 P parser comment 51 definition 47 designing 49 destination 45 macros 47 58 name 46 remove 47 scales tolerance level 55 selector 51 setup 43 setup button 46 syntax 50 types 49 delimiter 56 numbers 52 position 53 scales 54 protocol 12 22 Q quick start 9 QuickSheet 69 S scales 54 setup instruments 10 19 user info button 66 special functions data 56 header 56 units 56 special keys 3 spreadsheet changing columns rows 82 editing a cell 82 float entry 74 formula 74 formulas 79 loading 71 moving around 71 saving 72 scolling 71 selecting cells 70 text entry 74 spreadsheet destination 33 spreadsheet menu 42 edit clear 79 fill 76 font 77 format 73 float 73 save as 76 status line 5 T time stamping 61 timeout 12 22 tolerance level 55 U user info 30 66 user prompts 63 V view monitor 39 view spreadsheet 39 W window menu 42 close all 42 INDEX Index 3
90. would represent a carriage return 33 CHAPTER A Opening Instruments 34 Opening the Instrument Once you have specified where to send the instrument data through the Instrument Data Destination dialog box see Figure 4 3 Page 31 click on the OK button located along the bottom of the dialog box Doing so will confirm the Destination details and open the instrument Anew window will open in SWD Collect with that instrument s name appearing at the top Depending upon which destinations were specified you will see either a blank window Monitor selected or a window that includes the spreadsheet Spreadsheet selected similar to the example shown in Figure 4 5 Edswo collect BIslE Instruments Spreadsheet Configure Options Window Help gt Slel elgalal elei F 2 Figure 4 5 Spreadsheet Note the additional menu options available across the top of the dialog box Please refer to the section Using the Additional Options Available on Page 38 If you selected the Keyboard destination then SWD Collect will search your system for any running version of the specified Application or of the program identified through the Command Line If the application is already running you will see a warning message Clicking on the OK button will open a new version of the application If there are no versions of the application running then the Command Line is executed and the application is run The specified
91. y the number of Timeouts the program is to detect before parsing begins The default for this option is 1 one which will be the most common entry This means that after every Timeout the program will parse the data and send it to the specified destination CHAPTER 3 Configuring Instruments If your instrument transmits data over more than one stage you may want to delay Parsing until all the data is received For example if you know that your instrument describes a sample in 3 stages then you can set the Number of Timeouts to 3 In this case the program will keep the incoming data in memory until it counts 3 Timeouts then it will begin parsing all the data Saving the Instrument Protocol Setup Once the Instrument Protocol Setup dialog box has been completed click on the OK button to save the configuration or click on Cancel to proceed without saving the setup Selecting OK will return the Setup Instruments dialog box see Figure 3 2 Page 20 with the name of the created instrument listed and highlighted If you clicked on Cancel a Caution message will appear see Figure 34 Setup not saved Do you want to save current changes j No Cancel Figure 3 4 Do you want to save current changes Click on the Yes button if you wish to save the changes the No button to proceed without saving the configuration or the Cancel button to return to the Instrument Protocol Setup dialog box see Fig
92. your instrument so that you can observe the entry of data AutoScroll also causes data to be placed in the currently selected cell so you may direct where the data values appear The AutoScroll feature will be active every time this instrument is opened with the Spreadsheet as a destination unless you switch it off again Click AutoScroll again to turn this feature off AutoStarting your Instrument Click on the open instrument to make it the active window 2 Pull down the Options menu 3 Click on the AutoStart sub menu item to have a check mark appear beside the word AutoStart SWD Collect will automatically open this instrument when you restart the program with the current configuration and destinations The AutoStart must be switched on for each instrument that you want to have opened automatically Note that User Prompts will not be automatically requested when an instrument is AutoStarted Click AutoStart again to turn this feature off CHAPTER A Opening Instruments AutoLoading a Spreadsheet This feature is used only when the Spreadsheet is selected as a destination Click on the open instrument to make it the active window 2 Pull down the Options menu 3 Click on the AutoLoad sub menu item to have a check mark appear beside the word AutoLoad A Set Spreadsheet for Autoload dialog box will open asking you to specify the drive directory and file name for an existing spreadsheet SWD Collect w