Home

LAN-DMX STAGE-PROFI

image

Contents

1. Com86 Com106 Com126 Com8 Com 07 Com127 Lom88 Com108 Com128 Com89 Com109 Com129 Com390 Com110 Com130 Com91 Com111 Com131 Com92 Com112 Com132 Com93 Com113 Com133 Com94 Com114 Com134 Com95 Com115 Com135 Com96 Com116 Com136 Com9 Com117 Com137 Com98 Com118 Com138 Com93 Com119 Com139 Com100 Com 20 Com140 Cancel Check Range 1 SelectAll Select None Uncheck Range 1 8 After the selection please confirm with OK 9 Click the selected ComPort green framed WWW DMX4ALL EU te LL LAN DMX STAGE PROFI 8 Then click Add Rx Port see picture CPR Manager 4 3 0 0 File ComPort Device Tools Help VW Add Remove kulsave 2 Refresh Search For Devices amp Excludy i Settings sr ae pice So BR rch ror Deukes All Com Ports 8 Com 8 New gt Com 1 8 Window s Port Name Window s Device Name Window s Service Name Com Status Closed Network Status Disconnected Reset to Defaults Cancel Mits 2 GIIGIIY s Buffer Writes Keep checked for bette write performance 7 Connection Timeout in seconds f m 8 New w Server Reconnect Timeout Reconnect 0 Reconnect Limit 0 forever No Net Close Listen Mode TCP Port Add To Firewall TCP Keep live Keep live ime msec KeepAlive Interval msec RFC 2217 DTR ln TruPort Service Host f TCP Port 7 WARNING If the Host is on the other side of a router or a remote firewall then UDP ports 30718 43282
2. Add To Firewall TCP Keep live Keep live Time msec KeepAlive Interval msec RFN 2217 DTR In Service Kst p TCP Port 7 WARNING If the Host is on the other side of a router or a remote firewall then UDP ports 30718 43282 and 43283 may need to be 1 added to the firewall s exclusion list You may experience trouble 2 opening this com port if these UDP ports are not excluded 3 Also some legacy device servers respond on UDP port 43283 If you 4 are unable to connect to a device server one possible cause is the 5 Firewall on this machine is blocking this port Press the Add Rx Port button to add this port to the Firewall If the button caption reads 6 Remove Rx Port then the port has already been added and can be 7 removed by pressing this button l 8 Remove Rx Pot TheFirewallistumedON Device List Collapse F IP Address Ports TCP Port Product P HW Address Network Interface Device Name Port Name 192 168 123 195 1 10001 gt lt Port 03 04 ee Add To Settings Change the Device and Port Names Launch Web Interface to Device Ready Modified 12 After this the ComPort will be assigned to the device CPR Manager 4 3 0 0 File ComPort Device Tools Help B addiremovel 11 2 Refresh gt Search For Devices Q exclude Hide amp Settings Com 8 Tests Com Ports All Com Ports Com 8 Com 1 8 Window s Port Name Lantronix CPR Port COM8 77 Window s D
3. address fisz 168 0 250 r Subnet mask 255 255 255 0 Default gateway 0 0 0 0 7 After finishing the input confirm with Next 8 Confirm with Assign once again Assign IP Address 9 Wait until the configuration is finished and leave the dialog with Finish Click the Assign button to complete the IP address assignment Progress of task Completed successfully Finish 10 Now close the Device Installer DM ee LAN DMX STAGE PROFI 12 Settings All settings will be stored after turning off and can only be changed with a renewed configuration The LAN DMX STAGE PROFI can be configured comfortable via PC Therefore use the program DMX Configurator Under the menu point Settings Hardware settings you find the setting possibilities shown in image 1 The minimal generated DMX Output signals can be set under Min output channels Note If you have adjusted the minimum number of output channels on one value and if they address a higher channel from the controlling software so the DMx signal will be generated up to this channel automatically The number of channels will NOT be saved permanently After confirmation with OK the interface will be configured and the settings will be stored permanently Hardiware 5 ethrgs Communication speed 33400 BAUD Swap OMS signal lines Min output channels as Image 1 Setting via DMX Configurator Note by usage with the program FreeStyle
4. and 43283 may need to be added th the firewall s exclusion list You may experience trouble opening Mis com port if these UDP ports are not excluded machine is blocking this port Press the Add Rx Port Nag port to the Firewall If the button caption reads on OO me why Remove Rx then the port has already been added and can be adaa poaait ton Add Rix Port The Firewall is turned ON a Device List Collapse IP Address Ports TCP Port Product ID HW Address Network Interface Device Name Port Name Modified This is necessary if your system has an activated firewall to unlock the UDP port for a fluently communication 10 Now click Search For Device and wait until the device is shown in the Device List CPR Manager 4 3 0 0 opie ifs File ComPort Device Tools WP Add Remove f Save 2 Refresh J Search For Devices amp Exclude Com Ports Hide amp Settings All Com Ports 8 Com 8 New gt Com 1 8 1 Window s Port Name Window s Device Name Com Status Closed 1 Window s Service Name Network Status Disconnected M Reset to Defaults Cancel Edits x K4 z k V Buffer Writes Keep checked for better write performance 7 gt Connection Timeout in seconds Com 8 New Server Reconnect Timeout Reconnect 0 Reconnect Limit 0 forever No Net Close Listen Mode TCP Port Add To Firewall TCP KeepAlive Keep live Time msec Keep live Interval msec RFC 2217 DTR ln TruPor
5. LAN DMX STAGE PROFI User Manual ovx jy WWW DMX DM mw ALL LAN DMX STAG E PRO FI 2 Description The LAN DMX STAGE PROFI is designed for a harsh stage environment Housed in an aluminium case with Neutrik XLR socket this interface provides everything what is needed in a robust operation mode The DMX Output is galvanically isolated raising the operational safety and protecting the LAN network against overvoltage For power supply the provided plug in power supply is needed A virtual COM Port must be invested in the system to run the LAN DMX STAGE PROFI interface with the existing software for other DMX4ALL PC Interface This enables a data exchange in the same way as the usage with a conventional serial port Special Features of the LAN DMX STAGE PROFI Interfaces Galvanically isolated DMX Output Aluminum case 3 pin Neutirk XLR socket DMX with 38 Updates second by 512 full channels LAN connection enables the using of WLAN components Power supply connection LAN connection DMX connection DM mw ALL LAN DMX STAG E PRO FI Scope of delivery 1x LAN DMX STAGE PROFI Interface 1x Plug in Power supply 5V DC 1x Network cable 1m 1 1 blue 1x Network cable 1m Cross Over grey 1x User Manual german 1x Installation CD 1x Power supply 1x Network cable grey 1x LAN DMX STAGE PROFI 1x Network cable blue Technical Data LAN Input 10 100 Mbit about standard RJ45 Connec
6. dows Installer 3 1 e Windows Imaging Component These Runtime Libraries are all included in the file driver _x32_x64_lan_stage_player zip There you also find the matching installation files for a 32bit or 64bit operating system please always pay attention on this The files have the description x32 for 32 bit or x64 for 64bit 1 Open the program Com Port Redirector 4 3 0 0 msi for the actual operating system e By using the CD you find the package in the file Drivers e Alternatively you can download the package under www dmx4all de After starting the program a Welcome dialog window is shown i Lantronix CPR 4 3 0 0 x86 Welcome to the Lantronix CPR 4 3 0 0 x86 Setup D Wizard F The installer will guide you through the steps required to install Lantronix CPR 4 3 0 0 x86 on your computer WARNING This computer program is protected by copyright law and international treaties nauthorized duplication or distribution of this program or any portion of it may result in severe civi riminal penalties and will be prosecuted to the maximum extent possible under the law 2 Click Next to continue The dialog for selecting the installation directory is shown DM eae LAN DMX STAGE PROFI i Lantronix CPR 4 3 0 0 x86 Select Installation Folder The installer will install Lantronix CPR 4 3 0 0 x86 to the following folder To install in this folder click Next To install to a different folder enter it bel
7. evice Name Device CprDeviced Com Status Closed 17 Window s Service Name CprDryr Network Status Disconnected Ke Reset to Defaults Cancel Edits a 4 Buffer Writes Keep checked for better write perffrmance 7 Connection Timeout in seconds z Com 8 Server Reconnect Timeout Reconnect 0 Reconnect Limit 0 forever No Net Close Listen Mode TCP Port Add To Firewall TCP Keep live Kefp live Time msec Keep live Interval msec RFC 2217 DTR In TruPort WARNING Ifthe Host is on the other side of a router or a remote firewall then UDP ports 30718 43282 and 43283 may need to be added to the firewall s exclusion list You may experience trouble opening this com port if these UDP ports are not excluded Service Host 192 168 123 195 10001 Also some legacy device servers respond on UDP port 43283 If you are unable to connect to a device server one possible cause is the Firewall on this machine is blocking this port Press the Add Rx Port button to add this port to the Firewall If the button caption reads Remove Rx Port then the port has already been added and can be removed by pressing this button oN nom WN Remove Rx Port The Firewallis turned ON Device List IP Address Ports TCP Port Product 192 168 123 195 1 10001 Port 03 04 Collapse EB ID HW Address Network Interface Device Name Port Name x5 00 20 4A CD 58 1D 192 168 123 1 13 Please store the settings wit
8. h Save and confirm the dialog with OK which appears possibly 14 Close the configuration program DM WWW DMX4ALL LL LAN DMX STAGE PROFI 10 Changing the IP of the LAN DMX STAGE PROFI Changing the IP of the LAN DMX STAGE PROFI is possible with the utility Device Installer Please proceed as follows to install the Device Installer and to adjust the IP 1 Start the Device Installer 4 3 0 2 msi in the file Device Installer Pay attention by selecting the right version for the actual operation system a By using the CD you find the package into the file Drivers b Alternatively you can download the package under www dmx4all de Follow the installation steps on the screen Start the installed program Lantronix Device Installer e Click to ssign IP In the following dialog you must quote the Hardware ID printed on the LAN DMX STAGE PROFI Note Don t forget to quote a hyphen after 2 marks 6 Now enter the P address and the Subnet mask Note The IP setting is in the delivery status 192 168 0 250 DM www ote LAN DMX STAGE PROFI 11 D Assign IP Address IP Settings Please fill in the IP address subnet and gateway to assign the device The subnet will be filled in automatically as you type but please verify it acy ues in an e below make it s it for accuracy Incorrect val he below fields can make s Fe impossible for your device to communicate and can cause network disruption Se IP
9. is device DM ALL WWW DMX4ALL EU DMX4ALL GmbH Reiterweg 2A D 44869 Bochum Germany Copyright 2010 DMX4ALL GmbH All rights reserve No part of this manual may be reproduced in any form photocopy pressure microfilm or in another procedure without written permission or processed multiplied or spread using electronic systems All information contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason see myself compelled to point out that can take over neither a warranty nor the legal responsibility or any adhesion for consequences which decrease go back to incorrect data This document does not contain assured characteristics The guidance and the characteristics can be changed at any time and without previous announcement
10. ow or click Browse Folder C ProgrammeLantronix CPR4 3 Browse Disk Cancel 3 Now select with Browse the file in which the installation should occur and confirm with Next A dialog for confirmation appears j Lantronix CPR 4 3 0 0 x86 Confirm Installation The installer is ready to install Lantronix CPR 4 3 0 0 x86 on your computer Click Next to start the installation Cancel lt Back 4 Click Next to install the program During the installation a dialog appears i Lantronix CPR 4 3 0 0 x86 Installing Lantronix CPR 4 3 0 0 x86 Lantronix CPR 4 3 0 0 x86 is being installed Please wait Cancel 5 Finish the program installation with Close u BE LAN DMX STAGE PROFI 7 i Lantronix CPR 4 3 0 0 x86 Installation Complete Lantronix CPR 4 3 0 0 x86 has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates to the NET Framework Close 6 Now start the installed program CPR Manager Therefore click Start in the Windows Toolbar and then click Programs Lantronix CPR 4 3 the dialog window appears bwr Safee Nol CTO T fee kpk seeded sh 7 Click Add Remove A dialog with available COM Ports appears Select the COM Port about which the LAN DMX STAGE PROFI should be addressed Com 1 Com101 Com121 Com82 Com102 Com122 Com83 Com103 Com123 Com84 Com104 Com124 Com 5 Com105 Com125
11. r Please select in nterface Setup DMX4ALL as device and select in accordance to the COM Port DMAX4ALL v com 3 Y lease restart FreeStyler to apply changes u ame LAN DMX STAGE PROFI 13 Use the STAND ALONE MODE This function is integrated from version 1 11 delivery from Q3 2008 The LAN DMX STAGE PROFIs StandAlone Mode provides the reproduction of a light scene without a connected PC Generating and transferring the light scene takes place with the program DMX Configurator you find on the attached CD or as download on our website www dmx4all de How to generate light patterns is described detailed in the user manual The following image shows the programs surface rator 14 3 3 International Create Fade Time IV D M Delete omoosoo Get DMRAN FRE ieee me WWW DMX4ALL DE m Step Om00s10 Repeat after last step Chi Ch2 Ch3 Ch4 Ch5 Ch6 Ch Ch8 Ch9Ch10Ch11Ch12 p Group p Master PSSST aa a es Bes E 4 ct orp ppp pp Zane _ i Delete Oe al Play BlackOut lt Memory 1 Memory 2 Memory 3 Memory 4 Memory 5 gt Note The specified time units by generating the light patterns can differ by replaying with the LAN DMX STAGE PROFI Hence these are only reference values lf the wanted light scene is generated select the light scene under Default Scene on Start 1 Then you can transfer the light scene into the LAN DMX STAGE PROFI b
12. t Service Host sf TCP Port WARNING If the Host is on the other side of a router or a remote 1 firewall then UDP ports 30718 43282 and 43283 may need to be added to the firewall s exclusion list You may experience trouble 2 opening this com port if these UDP ports are not excluded 3 Also some legacy device servers respond on UDP port 43283 If you 4 are unable to connect to a device server one possible cause is the 5 Firewall on this machine is blocking this port Press the Add Rx Port button to add this port to the Firewall If the button caption reads 6 Remove Rx Port then the port has already been added and can be 7 removed by pressing this button I 8 Add Rix Port The Fi ist d 3 Device List Collapse F 1 Ready 192 Di BE LAN DMX STAGE PROFI 11 Click with a right click on the found device and select Add to Settings CPR Manager 3 0 0 File ComPort Device Tools Help VW Add Remove flsale 2 Refresh gt Search For Devices amp Exclude Com Ports Hide G Settings All Com Ports 8 Com 8 New 2 Com 1 8 Window s Port Name Window s Device Name Com Status Closed Window s Service Name Network Status Disconnected y gt vo Y w Reset to Defaults Cancel Edits w Buffer Writes Keep checked for better write performance 7 Connection Timeout in seconds Com 8 New Server Reconnect J Timeout Reconnect 0 Reconnect Limit 0 forever No Net Close Listen Mode TCP Port
13. tion Data speed 38400 Baud about virtual COM Port DMX Output Continuous DMX transmission up to 512 channels 250kbaud 38 Updates s at 512 channels DMX Output galvanically isolated Power supply About provided plug in power supply 5V DC Windows driver Win 98 Win 2000 Win XP Please take the current driver informations from our homepage DM En LAN DMX STAGE PROFI 4 Connection For the LAN DMX STAGE PROFI interface are different LAN Connection cable available not included in the scope of delivery Connection for one hub Please use the 1 1 network cable for the connection via one hub as shown in the following image 1 1 network cable Direct connection to PC Please use a cross over network cable for the connection directly to PC as shown in the following image Laptop PC Cross Over network cable Connection via WLAN For connecting via WLAN you need an Access Point with Ethernet connection Here you connect the LAN DMX STAGE PROFI Interface 1 1 Network cable WLAN Acces Point Laptop PC mit WLAN DM En LAN DMX STAGE PROFI Installation The LAN DMX STAGE PROFI interface operation needs the installation of a virtual COM Port on the PC Please follow each installation steps Depending on operating system and installed service package specific conditions Runtime Libraries are necessary e Microsoft NET Framework 4 0 e Microsoft Win
14. y selecting under menu Hardware Write memory 2 After finishing the transfer you can separate the PC connection and run the interface with an external power supply The stored light scene will be replayed until data from PC are received u ee LAN DMX STAGE PROFI 14 CE conformity This assembly board is controlled by a microprocessor and uses high frequency 8MHz To get the characteristics of the assembly in relation to the CE conformity an installation in a compact metal casing is necessary Risk Notes You purchased a technical product Conformable to the best available technology the following risks should not excluded Failure risk The device can drop out partially or completely at any time without warning To reduce the probability of a failure a redundant system structure is necessary Initiation risk For the installation of the board the board must be connected and adjusted to foreign components according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the installed systems components could as well as hidden defects cause to breakdown within the running time Misusage risk Any nonstandard use could cause incalculable risks and is not allowed Warning It is not allowed to use the device in an operation where the safety of persons depend on th

Download Pdf Manuals

image

Related Search

Related Contents

Descargar pdf  User Guide - CloudScale Project    Fiche produit Acrystal Prima  メールマガジン「事業用自動車安全通信」第205号(H25.7  Motorrahmen  Manual de Usuario  Régulateur CONTROL Série 603 pour la  9255084 Nuvola3 Comfort HT (ediz.2-10-09)20110831100658  User Guide - Soundcraft  

Copyright © All rights reserved.
Failed to retrieve file