1. GSM Emergency Alarm System User Manual Profile For a better understanding of this product please read this user manual thoroughly before using it ll 1 Features Adopt GSM 850 900 1800 1900 bands can be used all over the world Can per set 5 phone numbers when there is an alarm it will call these numbers in order Can per set 5 SMS numbers when there is an alarm it will send SMS to these numbers Maximum 30 wireless sensors including wireless panic button or remote controllers etc 2 wired ports to connect wired sensors The SMS content of the first 5 wireless sensors can be edited by users Support remote listen in and two way communication connect an external speaker SMS alert for power failure or recovery Built in backup rechargeable battery to keep working after power off Preparation before use Insert SIM card in alarm system Before inserting SIM card please make sure Use a regular mobile phone to set PIN code request to off Delete all stored numbers Make sure there s enough balance in the card to work normally Open the outside case of the alarm system and put the SIM card into the card slot see picture SIM card 2 Connect all devices needed a Connect the alarm siren optional b Connect the two way intercom speaker optional c Connect wired sensors optional 3 Power Plug in the power adaptor and turn on the backup battery switch The LED indicator will flash and the
2. If the password is input wrong there will be three short beeps while a long beep means correct A long beep means password is correct while three short beeps mean wrong you need to input again If the password is wrong for consecutive three times the call will be hung up automatically If there s no input within 30seconds after getting through the call it will also be hung up automatically Operation by SMS User can send sms to remotely arm or disarm the system Arm remote control password default 123456 1 fi Disarm remote control password default 123456 2 VI Technical Parameters Power DC12V 1 2A Status current lt 30mA GSM bands 850 900 1800 1900MHz Wireless receiving frequency 433MHz 0 5MHz Receiving code ASK Wireless distance no obstacle 80m Working temperature 10 45 C Working humidity lt 90 Backup battery 7 4V 500mAh VII Standard Kit Alarm panel 1pc Power adaptor 1pc User manual 1pc 12
3. example you send 888888 96 panel alarm you will receive a sms gt OK sms message SOS panel alarm 5 Factory reset Press the RESET button for 5 seconds until the LEDs on the panel are flashing quickly After this operation all the settings return to factory default V Operation Instruction 1 Answer alarm call When there is an alarm the ALARM LED on the panel will be on and the external siren if user has connected will ring for 3 minutes if there s no operation Also the device will send alarm SMS to and call the preset numbers Press DISARM button on the main panel or the remote controller it will stop the alarm The alarm system will keep calling all the preset numbers in order if nobody answers the call The default circle time is 3 10 If someone answers the call it will enter listen in status automatically and the siren stops ringing Then user can press 1 to arm 2 to disarm 3 to listen in and 4 to intercom this function needs external speaker A long beep means correct operation and three short beeps means wrong operation 2 Remote control operation Operation by remote call When users are outside and want to monitor the alarm system he can call the alarm panel After getting through the call user will hear a long beep Then press remote control password default 123456 and to enter listen in status User can hear the sound around the alarm panel
4. ors Press the reset button at the back side of the panel there will be a shot beep and the STATUS LED will be on red indicating the device enters coding status Trigger the wireless sensor you want to code there will be a long beep and the STATUS LED will flash in green The sensor is set successfully The sensors will be numbered in consecutive order automatically according to the coding sequence That means the first panic button coded is No 1 the second is No 2 and the like The default alarm SMS is xx Emergency ALARM xx means the serial number of the sensor If the sensor quantity exceeds 30pcs the exceeded sensor will replace the coded one from No 1 2 Exit coding In coding status press RESET button again Or if there s no operation within 5seconds after entering coding status it will exit coding automatically 3 Settings by call Users can use a mobile phone or fixed line telephone to call the number of the host to set alarm call numbers It can store maximum 5 numbers After setting the host will call these numbers when alarm Setting method after getting through the call users will hear a long beep Then press operation password default 888888 and A long beep means password is correct Three short beeps mean password is 6 wrong you need to input again If the password is wrong for consecutive three times the call will be hung up automatically If there s no input within 30seconds after get
5. the circle time 4 Settings by SMS Use your mobile phone to send a message to the number of the device All the above settings in Table 1 can also be set by SMS And they should begin with operation password The default password is 888888 For example 1 888888 30 1 12233 change the remote control password into 112233 2 888888 52 13412345678 set the third alarm call number as 13412345678 3 888888 01 0 turn off the function of SMS alert for power failure 4 888888 02 5 set the alarm call circle as 5 times All the following commands in Table 2 can also be set by SMS The SMS should begin with operation password The default password is 888888 Table 2 Change alarm message of SOS button on main panel 96 message content Message content should not exceed 25 English letters Default SMS 00 Emergency ALARM Change alarm message of wireless panic button 91 95 message content 91 the 1st wireless sensor 92 the 2nd wireless sensor Message content should not exceed 25 English letters Default SMS XX Emergency ALARM XX means the haai serial number of 95 the 5th wireless wireless sensor sensor Delete alarm 91 95 message Note After successful setting user will receive a SMS reply with the content of gt OK If the SMS setting format is wrong user will receive FORMAT ERROR For
6. ting through the call it will also be hung up automatically After password and users can do the following settings Table 1 Function setting Setting format Change remote control password 30 new password Password should be 6 digit Default 123456 Change operation password 31 new password Password should be 6 digit Default 888888 Alarm call number setting 50 54 number 50 the 1st number 51 the 2nd number 54 the 5th number Number should not exceed 20 digit Delete call number 50 54 Alarm SMS number setting 55 59 number 55 the 1st SMS number 56 the 2nd number 59 the 5th number Number should not exceed 20 digit Delete SMS number 55 59 Turn on power LED O0 1 Default on Turn off power LED 00 0 Power failure recovery 01 1 ON Default on alert 01 0 OFF Alarm call circle time 02 1 9 Default 3 Siren rings when alarm 03 1 Default on Siren off when alarm O3 0 Note a Power failure recovery alert after activating this function when the external power supply is off user will receive a message POWER DOWN If the power recovers after failure the message is POWER UP b Alarm call circle time when there s nobody answers the alarm call the device will call all the alarm phone numbers in circle automatically This is to set
7. unit starts checking the GSM network 4 Do the needed settings check Part System Settings in detail lll Host 1 LED status explanation LED LED Status System working status ON it can also be POWER power supply is normal set as off aye Red flash quickly Check SIM card and search GSM network Red flash every 3 SIM card and GSM signal are normal seconds Red In coding status wait to set sensors STATUS Green In arm status Green flash quickly Sensor is set successfully Red and Green flash Receive correct setting SMS alternately Listen in status users can hear the voice MONITOR On from the scene ALARM On Alarming status 2 Host panel Status indicator MIG Reset SOS button External power Disarm SPK Negative of two way intercom speaker black cable SPK Positive of two way intercom speaker red cable IN2 Wired sensor GND GND IN1 Wired sensor GND GND OUT Positive of siren red cable GND Negative of siren black cable IV System Settings This device has two passwords Remote control password used for remote listen in and two way intercom Default 123456 Operation password used for system settings Default 888888 Note These two passwords could not be set as the same 5 1 Coding of wireless sensors This device supports maximum 30pcs wireless sens

Download Pdf Manuals

image

Related Search

Related Contents

AT&T FAX Attendant Release 2.1.1 User's Manual  User manual - Aka Detectors  Eglo 20393A Installation Guide  CR Pro User Manual Version 2.0  Event notification system and method  Massive Spot light 55269/29/10  Cisco Systems 3620 User's Manual  Best Mounting D1-11139-W09 flat panel desk mount  electronic chair scale bascula electronica con silla fauteuil de pesée  La pédagogie de projet - Réseau Ecole et Nature  