1. The EU directive 93 42 EEC was applied in the design and production of this medical device NAKANISHI INC t l www nsk inc com NSK Europe GmbH www nsk europe de Elly Beinhorn Strasse 8 8 www nsk uk com 700 Shimohinata Kanuma shi Office 5 Gateway1000 Tochigi 322 8666 65760 Eschborn Arlington Business Park Whittle Way Japan Germany Stevenage SG1 2FP UK NSK France SAS NSK Dental Spain SA NSK Oceania Pty Ltd www nsk inc com Unit 22 198 222 Young St Waterloo Sydney NSW 2017 Australia www nsk fr www nsk spain es 19 avenue de Villiers C M dena 43 El Soho Eurdpolis 75017 Paris 28232 Las Rozas Madrid France Spain Specifications are subject to change without notice rer NSK United Kingdom Ltd NSK America Corp www nsk inc com 700 Cooper Court Schaumburg IL 60173 USA NSK Middle East NSK Asia www nsk inc com www nsk inc com Room 6EA 701 7th Floor East Wing No 6 1 Maritime Square Dubai Airport Free Zone 09 33 HarbourFront Centre PO Box 54316 Dubai UAE Singapore 099253 11 03 01 OPERATION MANUAL Push button Contra Angle Handpiece ZIOL Z10 a f FALZ gt M Z85L Z85 i Max ZS Ti Max ZC Please read this Operation Manual carefully MADE IN JAPAN x before use and file for future reference OM C0442E Powerful Partners Intended to use This handpice is intended only for dental clinic dental office use N CAUTION When
2. Ww D shape Fig 1 Push Button 1 Fig 2 HSIMONA 5 4 2 Removing the Bur Fig 3 1 Push the push button with a thumb 2 Pull out the bur 5 Maintenance After the treatment be sure to perform the maintenance below 5 14 Cleaning Handpiece ik This handpiece can be washed via Thermo Disinfector Scrub dirt and debris from the handpiece and wipe clean with alcohol immersed cotton swab or cloth Do not use a wire brush Refer the manual of Thermo Disinfector for performing it Push Button oO Fig 3 5 2 Cleaning Z10L Z15L Z25L Z85L Z95L Wipe clean the Cellular Glass Optic Rod entry point and exit point with an alcohol immersed cotton swab Remove all debris and oil Fig 4 N CAUTION Do not use a pointed tool or sharp edged to clean the Cellular Glass Optic Rod They may damage the mirror finish and reduce the light transmission efficiency If Cellular Glass Optic Rod end has become damaged return it to dealer for repair 5 3 Lubirication and Sterilization Refer to the Maintenance Guide OM Z0135E Cotton Swab Glass Rod Fig 4 HSITDNA 6 Warranty NSK warrants the handpiece against production errors and material defects NSK reserves the right to analyze and determine the cause of any problem Warranty is voided should the handpiece be not used correctly Replacement parts are available for seven years beyond discontinua
3. m 16 5mm 25mm Max Bur diameter 4 0mm 2 0mm HSIMONA 2 2 Disconnecting Hold the motor and the handpiece and pull it out Z N CAUTION Connect ONLY E type motor IS03964 and do not exceed maximum motor speed such as shown on the specification 3 Check before treatment Follow the check below before use If any abnormalities are found stop using the handpiece immediately and contact the authorized NSK dealer 1 Insert the Bur Do not exceed maximum rotation speed for any item 2 Check that there is no abnormal rotation vibration noise and overheating 3 If there are no immediate apparent abnormalities continue to rotate the handpiece for about 1 minute Then check that there is no abnormal heating on the outer surface 4 Operate it if there are not abnormalities above 4 Mounting Removing the Bur 4 1 Mounting the Bur 4 1 1 Mounting the Bur Contra Bur to Z10 Z10L Z15 Z15L Z25 Z25L 1 Connect handpiece and motor 2 Insert and llightly turn the bur until it engages with the latch mechanism Fig 1 3 Push the bur further inwards until it clicks into place 4 1 2 Mounting the Bur FG Bur to Z85 Z85L Z95 Z95L 1 Connect handpiece and motor 2 Depressing the push button and insert the bur into the chuck Fig 2 N CAUTION After the Bur is locked in place lightly pull out the Bur to make sure the Bur is locked If the Bur is not correctly secured it may release during operation and can cause injury
4. operating the Handpice always consider the safety of the patient Check for vibration noise and overheating outside the patient s oral cavity before use If any abnormalities are found stop using the Handpice immediately and contact dealer Should the Handpice function abnormally cease operation immediately and return the Handpice to dealer for repair Depressing the push button while the handpiece is rotating will result in OVERHEATING of the handpiece head Special caution must be exercised during use to keep cheek tissue AWAY from the push button of the handpiece Contact with cheek tissue may cause the push button to depress and burn injury to the patient may occur Do not attempt to disassemble the handpice or tamper with the mechanism Do not allow any impact on to the Handpice Do not drop the Handpice Do not connect or disconnect the Handpice or bur until the drive motor has completely stopped Do not use bent deformed or damaged bur If these burs are used it bends suddenly or it breaks during rotation Bur may become difficult to remove because latch groove is worn or it has swollen HSITSN4 Always keep bur shanks clean Dirt or debris in a chuck could cause poor bur concentricity or low chuck retention force Do not exceed the drive motor speed recom mended the bur manufacturers Before use always confirm that the bur is correctly seated and locked into place Always use with adequate wate
5. r supply and Use eye protectors dust mask for safety an Perform periodical maintenance checks coolant air or damage to the tooth structure may occur and overheating d health during treatment If the handpiece has not been used for a long period check for noise vibration and overheating before use Do not wipe nor immerse the handpiece aci dic water or acidic solutions User is responsible for operation maintenance and safety Z85 Z85L breakage Z95 Z95L Use short shank FG Bur for a mini head If long bur has used it may cause of the omission of early wear of a bearing Bur will bend and Do not use long surgical burs Do not use burs longer than 26mm If a foreign material enter to the gear and inside of handpiece it may become a cause of burn injuries 1 Specification 2 Connecting Disconnecting handpiece and Motor 2 1 Connecting 1 Align the handpiece and motor alignment pin 2 Then push the handpiece directly into the motor in alignment with the pin Model Z10L Z10 Z15L ANS Z25L 725 Z85L Z85 Z95L 295 Max Rotation Speed 40 000min Gear Ratio 16 1 4 1 Hil 15 Bur ISO 1797 1 Type1 02 35mm Contra Bur SO 1797 1 Type3 Short Shank FG Bur ISO 1797 1 Type3 01 60mm FG Bur Optic OPTIC NON OPTIC OPTIC NON OPTIC OPTIC NON OPTIC OPTIC NON OPTIC OPTIC NON OPTIC Bur applied Length 12 5mm 9 8mm 10 5mm Max Bur Length 22 5m