1. External contact header Please note the sensor will not operate the reed switch and external contact header simultaneously BATTERY ACTIVATION To activate the batteries in the sensor remove the cover and pull out the plastic tabs between the batteries and the contacts QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 2 OF 6 Last revised 12 9 14 All rights reserved IQ DOOR WINDOW INSTALLATION MANUAL Yolsys MOUNTING WITH PROVIDED ADHESIVE eRemove backing on one side of the large double sided tape and stick the exposed side on the back of the sensor as shown eRemove the other side of the large double sided tape and mount the device according to the installation instructions eRemove the backing one side of the small double sided tape and place on back of magnet eLineup the magnet with the sensor using the arrows shown on each device respectively Ensure the sensor and magnet are not separated more than 0 4 inches as shown eRemove the second side of the double sided tape and secure the magnet MOUNTING WITH PROVIDED HARDWARE eRemove the back of the sensor by pressing on the tab and pulling the cover off Push to remove sensor cover ePlace the base of the sensor on the appropriate surface and use 4 of the supplied screws to secure the mounting plate to the chosen location eTo secure the magnet remove the mounting plate by prying it off the magnet casing eBe sure the arrows on the top of the ca
2. IQ DOOR WINDOW INSTALLATION MANUAL Solsys IQ DOOR WINDOW The Qolsys IQ Door Window is a sleek high performance wireless sensor that detects opening and closing of doors windows and anything else which opens and closes drawers cabinets etc It works seamlessly with the Qolsys IQPanel TECHNICAL SPECIFICATIONS Wireless signal range 60Oft 200M open air Code outputs tamper tamper restore alarm primary open alarm restore primary close external alarm secondary wired open external restore secondary wired closed low battery Transmitter frequency 319 5MHZ Unique code ID Supervisory keep alive interval 70 minutes RF Peak field strength typical 36000 uV m at 3m PARTS INCLUDED PRODUCT FEATURES 1 Door Window Sensor eLow profile oo Supports one or two doors windows etc screws D 1 large strip of double sided adhesive Primary wireless magnet contact and secondary wired 1 small strip of double sided adhesive contact Internal or external reed switch Easy wire free installation Secondary optional sensor external wired Door Window sensor eAdvanced circuit technology resulting in ultra low power consumption Easy to install Batteries Over 5 years of battery life Tamper Detection Supervisory health messaging Sensor Open and Close detection QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 1 OF 6 Last revised 12 9 14 All rights reserved IQ DOOR WINDOW INSTALLATION MANUAL Y
3. let on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 8 RSS GEN Section 7 1 3 7 1 3 User Manual Notice for License Exempt Radio Apparatus This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Document IQDW IM 12 14 Revision 12 9 14 lt Conforms to ANSI UL Std 634 Issue Date DEC 2014 c US n to ULC Sub C634 olsys Inc proprietary Qolsys Product QS 1100 PO1 o Reproduction without permission is not permitted Firmware OA_20121130 Intertek QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 6 OF6 Last revised 12 9 14 All rights reserved
4. olsys GUIDELINES eMount the sensor on the door frame and the magnet on the door If the sensor is used on double doors mount the sensor on the least used door and the magnet on the most used door elf possible locate sensors within 100 ft 30 m from the panel eWhile a transmitter may have a range of 600 ft 200 m or more out in the open the environment at the installation site can have a significant effect on transmitter range Some times a change in sensor orientation can help overcome adverse wireless conditions eMake sure the alignment arrow on the magnet points to the alignment mark on the sensor ePlace sensors at least 6 in 15 24 cm above the floor to avoid damaging them eAvoid mounting sensors in areas where they will be exposed to moisture or where the sensor operating temperature range of O to 120 F 0 to 49 C will be exceeded eUse spacers not included to keep sensors and magnets away from metal or metallic surfaces such as foil wallpaper eAvoid mounting sensors in areas with a large quantity of metal or electrical wiring such as a furnace or utility room PLACEMENT AND SPACING Be sure to align the triangle guides on the sensor and magnet as shown This will enable the proper contact between the sensor and magnet When closed the magnet should be within 4 of the sensor for optimum sensitivity O0 4in 1cm l l Battery retention clips KA magnet Sensor
5. port Qolsys com QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 5 OF 6 Last revised 12 9 14 All rights reserved IQ DOOR WINDOW INSTALLATION MANUAL Yolsys IMPORTANT INFORMATION 15 21 15 21 Information to user The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment 15 105 b 15 105 Information to the user b NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an out
6. sing align with the arrows on the sensor casing The sensor and magnet should not be mounted more than 0 4 inches apart eUse the 2 remaining screws provided to secure the magnet mounting plate in the proper location Clip the magnet casing back into place once the plate is secure QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 3 OF 6 Last revised 12 9 14 All rights reserved IQ DOOR WINDOW INSTALLATION MANUAL Yolsys PROGRAMMING THE IQ DOOR WINDOW The following steps describe general guidelines for programming learning the sensor into the IQ Panel Refer to the IQ Panel s installation instructions for complete programming details From the home screen of the IQ panel touch the 2 Settings icon Enter the installer passcode Default installer passcode is 1111 Touch the Installation app 4 Touch the Security Sensors app A Touch the AutoLearn Tamper the sensor by pressing the 5 Sensor app 4 tab and lifting off the cover Auto Learn Sensor al A chime will sound 7 Sensor 75240 is requesting to be added to your list Do you want to continue Touch Ok 8 Sensor DLId Enter Sensor DL Id Sensor Type Door Window y S N Front D i a z Check the auto populated fields to ensure accuracy Chime Type Highwire v Customize device settings as desired Sensor Group 10 Entry Exit Normal Del annasman anaiai ines Voice Prompts On y a aaar Create c
7. ustom names by selecting Sensor name and 9 Sensor Name Custom Description W Sarahs Bedroom Window choosing Custom description A keyboard will appear allowing you to type the name of your choice into the field 1 O mae Click Add to complete the process QOLSYS CONFIDENTIAL AND PROPRIETARY PAGE 4 OF 6 Last revised 12 9 14 All rights reserved IQ DOOR WINDOW INSTALLATION MANUAL olsys BATTERY REPLACEMENT To replace batteries Push to remove i nsor cover Push tab on side of sensor and lift off cover sensor cove Place fingernail or small screwdriver under the battery and gently lift up The battery should release easily Remove old battery Replace with a new battery by putting one end under the golden battery retention clip Gently push toward the opposite side until the the battery snaps into place under the black plastic eRepeat this process for the second battery Close cover by snapping the cover back onto the sensor Battery retention clips BATTERY TYPE a switch 3V CR2032 Lithium 2 batteries per sensor External 5 years battery life contact header ENVIRONMENTAL CHARACTERISTICS Operating Temperature 10C 50C Relative Humidity 5 95 Non Condensing Storage Temperature 40 80C PHYSICAL SPECIFICATIONS Sensor 3 25H x 1 3W x 1D in 8x3x1 5 cm Magnet 1 3H x 0 435W x 0 312D in 3 3 x 1 1 x 0 79 cm SUPPORT GOT QUESTIONS CONTACT TECH SUPPORT TechSup