Home
User Manual
Contents
1. Entry Mode used when additional proximity or keypad reader is connected Remote Relay Touch Function Enabling Disabling the Touch Button Function in the remote relay Unit Buzzer Enabling Disabling the Buzzer Backlight Enabling Disabling the Backlight 11 0 DINB100 SA PROGRAMMING MENU 11 7 Settings 11 7 1 Double Swipe Unlocks Door Entry Mode Remote Relay Touch Function Double Swipe Unlocks Door p Entry MODE LJ Remote Relay Touch Function Double Swipe Unlocks Door im Scroll down to select By swiping finger select entry tm mode Scroll down to select Finger 3 Finger AND Card Finger OR PIN E Finger ON Card Finger AND PIN 10N 2 OFF Finger OR Card product ver 1 0 2 0 0 d Back to MAIN MENU Back to MAIN MENU Note Refer to Chapter 10 for this feature Back to MAIN MENU NOTE Swipe UPWARDS to exit the MENU Example Task Set the Reader to work in Finger and Card mode Scroll Master Finger 10 times tap scroll twice tap scroll 4 times tap swipe UP to exit 11 0 DINB100 SA PROGRAMMING MENU 11 7 Settings 11 7 2 Buzzer Sound Backlight Reset to defaults Buzzer sound J Backlight LJ Reset to defaults _ Buzzer ON OFF tn Scroll down to select Reset to defaults din Tap to confirm Backlight ON OFF in Scroll down to select
2. Swipe finger or present Card N or enter PIN NOTE Swipe UPWARDS to exit the MENU 11 3 Delete All Users Tap sensor ty to confirm or swipe UP to Cancel Note The Master and the Administrators will not be deleted Back to MAIN MENU NOTE Swipe UPWARDS to exit the MENU 11 0 DINB100 SA PROGRAMMING MENU 11 4 Delete Group of Users Swipe the Master Admin finger 6 times until the light pattern on figure 13 is shown Figure 13 Si IN x6 l Select User Group to Delete tm Swipe the finger to select Group 1 Group 5 BL Group 2 Group 6 BL Group 3 Group 7 BL LA A0 Al Group 4 Group 8 Back to MAIN MENU NOTE Swipe UPWARDS to exit the MENU Note All fingers that are enrolled in the Group will be deleted Example Task Delete all users in Group3 Scroll Master Finger 6 times tap scroll twice tap swipe UP to exit 11 0 DINB100 SA PROGRAMMING MENU 11 5 Add Administrator Swipe the Master Admin finger 12 times until the light pattern on figure 10 is shown Figure 10 Select Admin nr Scroll down to select Admin 1 Admin 2 Orange Blinking Swipe the Admin finger min 6 times Until Ok beep IN x6 Note If keypad is connected enter the User Pin Code then swipe the user finger min 6 times U
3. 12 3 Delete User Group Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink BL ADMIN PIN or d x5 Enter group number 0 to 8 Press A to confirm To Exit press 0 A Note All fingers that are enrolled in the Group will be deleted 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 4 Delete All Users Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink EN Press 5 1 3 5 7 3 esa O To Exit press 0 A 12 5 Delete User by User Finger The Biometric reader starts to blink E lees Enter user PIN then press A or swipe the user finger To Exit press 0 A Swipe Master Admin finger or enter Admin PIN i ADMIN PIN or x5 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 6 Set Door Relay Time Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink EM Press 1 or 2 to select Relay1 or Relay2 3 Select the time code from the Table1 Table1 1sec 3 sec 5 sec 10 sec 20 sec 30 sec 60 sec Toggle ER Press Ato confirm To Exit press 0 A Example Task Put Relay1 to stay activated 10 seconds Scroll Master Finger 5 times press 2 press 1 press 4 press A press 0 A to exit 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 7 Buzzer Settings Swipe Master Admin finger or enter Admin PIN The Biome
4. To Exit press 0 A Remote Relay Touch Function Enabling Disabling the Touch Button Function in the remote relay Unit 12 10 Unpair Remote Relay Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink Press 7 1 5 9 Press A to confirm To Exit press 0 A 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 11 Entry Mode Settings Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink 2 Select the Entry Mode from the Table 5 Table 5 Entry Mode Finger Finger or PIN Finger and PIN Finger or Card Finger and Card Finger ON Card Es Press A to confirm To Exit press 0 A Example Task Set the Reader to work in Finger and PIN mode Scroll Master Finger 5 times press 3 4 press 3 press A press 0 A to exit 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 12 Add Administrator BL Me Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink V x5 L ope EE Press 1 or 2 to select Admin1 or Admin Efessmem Enter Admin PIN code 1 to max 8 digits Press A to confirm Swipe the Admin finger min 6 times Until Ok Beep IN x6 To Exit press 0 A There is 1 Master Finger but no master PIN Code The master finger can enroll delete user and all the other settings The Master finger can be changed ONLY with the jumper
5. k ccess EN DINB100 SA DINRTT D N B100 SA K IT Standalone Biometric Kit User Manual Contents 1 0 INTRODUCTION Lee eee eee eee eee eeee 3 2 0 MOUNTING AND DISMOUNTING eee 3 3 0 SPECIFICATIONS dd ee ee eee 3 4 0 APPLICATION DIAGRAM de ee ee eee eee 4 BORING eege 4 6 0 RECOMMENDED SWIPING TECHNIQUE ____ loll le eee 5 6 1 Tapping the sensor dd cece cee ee cee cece eee nee eae 5 6 2 Scrolling the sensor up and down dd cece ee cee eee ee cece eee eee enna 5 Z O INDICATION eessen eege Eege Red 5 8 0 QUICK PROGRAMMING eee nan 6 8 1 Adding Master Finger and delete all users inn eee e cece ceeeecccceees 6 8 2 AddUserIn Group ded hele ee ee eed etescede tice tedden ted et edna dedice sees 7 8 3 Add User In Group 2 eee eee ee ee eee ee eee eee 7 8 4 Delete user cece ccc cece cece cece ence cece eee 7 8 5 Delete All Users i Group 1 Lee ee eee eee eee eee eee 7 8 6 Delete All Users in Group2 nine 7 9 0 PAIRING BIOMETRIC READER AND REMOTE RELAY UNIT sss 8 9 1 Pairing DINB100 SA with DINRTT Edna sd abas ni EE EES 8 9 2 Pairing DINB100 SA With RI 8 10 0 KEEP THE DOOR UNLOCK a 8 11 0 DINB100 SA PROGRAMMING MENU aa 9 a Mes Po fo Tal EC 9 11 2 Delete User ccc cece eee eee eee cece nnn nnana nannan nann nann nannan 10 11 3 Delete All ysers e 10 11 4 Delete Group of Users 6d cee eee ee eee ee been ee ene eee eee ee eens 11 11 5 Add Administrator ee 12 11 6 Delete Administrator EEE
6. Swipe ANY enrolled finger twice within 7 seconds and the Door will stay unlocked until valid finger is swiped While the door is unlocked the tricolor status LED stays green User Finger x 2 To use this feature enable the same from the menu page 15 It applies for product version 1 0 2 0 0 and above Note Make sure that the door lock can withstand activation in longer periods At 11 0 DINB100 SA PROGRAMMING MENU 11 1 Adding Users Swipe the Master Admin finger 5 times until the light pattern on figure 9 is shown Figure 9 Swipe the finger to select Group 1 Group 5 Group 2 Group 6 Group 3 Group 7 Group 4 Group 8 Relay 1 Relay 2 NOTE Swipe UPWARDS to exit the MENU GC Orange Blinking Swipe the user finger for Finger mode min 6 times When using proximity reader for Finger Or and Card Mode first present the Card then swipe the finger min 6 times When using keypad for Finger Or And Pin Code mode first enter the PIN Code then swipe the finger min 6 times Example Task Add a user in Group2 that will activate Relay1 Scroll Master Finger 5 times tap scroll ones tap tap swipe user finger 6 times swipe UP to exit 11 0 DINB100 SA PROGRAMMING MENU 11 2 Delete User Swipe the Master Admin finger 7 times until the light pattern on figure 12 is shown Figure 12 Blinking row gt
7. There are 2 Administrator Fingers and 2 Administrator PIN Codes In order to enrol Admin Master Finger MUST be enrolled first The administrator can do all the things that Master can do The Master can delete the Administrator but the Administrator can not delete the Master 12 13 Delete Administrator Swipe Master Admin finger or enter Admin PIN ge ADMIN PINor JA x5 The Biometric reader starts to blink EN Press 1 or 2 to select Admin1 or Admin 3 Presao O To Exit press 0 A 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 14 Reset to defaults product ver 1 0 2 0 0 Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink EN Press 9 1 4 7 3 Ieesnyene Note Does not affect the fingerprints stored and the pairing To Exit press 0 A 12 15 Double Swipe Unlocks Door product ver 1 0 2 0 0 Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink 2 Select the Double Swipe from the table 1 Enable 2 Disable To Exit press 0 A Note Refer to Chapter 10 for this feature This product herewith complies with requirements of EMC directive 2014 30 EU In addition it complies with RoHS directive EN50581 2012 Visual Plus Corporation s a Dr ve Richelle 161 O WH E WOP G Bte 34 o PAY 1410 Waterloo Belgium Access
8. procedure also deletes all the users and administrators previously enrolled 1 There is 1 Master Finger The master finger can enroll delete user and all the other settings The Master finger can be changed ONLY with the jumper 2 There are 2 Administrator Fingers The administrator can do all the things that Master can do The Master can delete the Administrator but the Administrator can not delete the Master 3 The User can be assigned to one of the 8 available User Groups With the Quick programming feature the Users are assigned in Group 1 or Group 2 For most of the installations 2 groups are enough and can be used as Group 1 for permanent residents Group 2 for guest and visitors 4 The user can be deleted by swiping its user finger or by deleting the group in which that user is enrolled Once the Group of users is deleted all the users within that group will be deleted 5 The Groups are not limited by the number of users ex Group 1 can contain 20 users Group 2 can contain 70 users but the total number must remain bellow 97 8 2 Add User In Group 1 N Master Finger x 1 1 Swipe the Master or Admin Finger Figure 1 2 Swipe the user finger min 6 times until Ok Beep d d N User Finger x 6 8 3 Add User In Group 2 N Master Finger x 2 1 Swipe the Master or Admin Finger twice 2 Swipe the user finger min 6 times until Ok Beep Figure 2 d NN User
9. 13 MUP SOCUINES eet ebe 14 11 7 1 Double Swipe Unlocks Door Entry Mode Remote Relay Touch Function _ 15 11 7 2 Buzzer Sound Backlight Reset to defaults E 16 11 8SetDoorRelayTime Lee ee ee 17 11 9 Adding Users In Finger On Card Mode when Mifare Reader is connected 18 12 0 PROGRAMING DINB100 SAWITH KEYPAD eee 19 12 1 Adding Users EEE 19 12 2 Delete User By User Location Number E 20 12 3 Delete User Group oo ccc cece cece eee eee r a a aea e a 20 12 4 Delete All Users e 21 12 5 Delete User by User Finger e e ee aa 21 12 6SetDoorRelayTime ee 22 12 7 Buzzer Settings ee 23 12 8 Backlight Settings hann 24 12 9 Set the Touch Button Function Lohana 25 12 10 Unpair Remote Relay nene ee 25 12 11 Entry Mode Settings sesniesaedcces ASAS aC DADA ace ABADE SARA EE 26 12 12 Add Administrator webtentatbaocteratslidacitientetdecetsestac eine TUA DEAD ada 27 12 13Delete Administrator Ze Eege Ee EES SS ad GA dada 27 12 14 Resettodeta lts uerge saia a a A a E a EARN 28 12 15 Double Swipe Unlocks Door Lo eee ee ee eee eee 28 1 0 INTRODUCTION DINB100 SA is a simple one door standalone biometric system The reader can store up to 97 finger templates it has one relay output and one exit button input If secure installation is needed the reader can be connected to remote relay unit at secured area which also plays the role of request to exit push button Proximity reader or keypad can be added for additional entry mode Card or
10. Finger x 6 8 4 Delete User NN Master Finger x 1 1 Swipe the Master or Admin Finger Figure 1 2 Swipe the user finger already enrolled d N User Finger x 1 8 5 Delete All Users in Group 1 see 1 Swipe the Master or Admin finger 3 times N Master Pingerx a i 2 Wait 6 seconds for the light pattern on figure 4 wait 6 seconds 3 Swipe the Master or Admin finger once more N Master Finger x 1 A Note All fingers that are enrolled in Group 1 will be deleted Figure 4 8 6 Delete All Users in Group 2 Gin N Master Finger x 4 6 sec 1 Swipe the Master or Admin finger 4 times 2 Wait 6 seconds for the light pattern on figure 6 wait 6 seconds 3 Swipe the Master or Admin finger once more Master Finger x 1 Note All fingers that are enrolled in Group 2 will be deleted N Figure 6 If you make any mistake or you just simply want to exit Quick Programming wait for the timeout of 10 seconds With this the quick programming is completed The system is now operational with default value for Door Open Time of 3 seconds For more comprehensive programming refer to the DINB100 SA Programming section Important When using proximity reader for Finger Or And Card Mode first present the Card then swipe the finger min 6 times When using keypad for Finger Or And Pin Code mode first enter the PIN Code then
11. Remote OFF Remote OFF Reader OFF Reader OFF BL All ON All ON All OFF All OFF product ver 1 0 2 0 0 Tap sensor dr OK Beep Back to MAIN MENU Note Does not affect the fingerprints OK Beep Back to MAIN MENU Back to MAIN MENU stored and the pairing NOTE Swipe UPWARDS to exit the MENU Example Task Put the Buzzer OFF Scroll Master Finger 10 times tap scroll 4 times tap scroll ones tap swipe UP to exit 11 0 DINB100 SA PROGRAMMING MENU 11 8 Set Door Relay Time Relay1 time for Relay 1 in DINB100 SA RTT and DINRTT Relay2 time for Relay 2 in DINRTT Remote Relay Unit Swipe the Master Admin Swipe the Master Admin finger 8 times finger 9 times Select relay open time Im Scroll down to select Scroll down to select 1 sec 20 sec 1 sec L 20 sec 3 sec 30 sec 3 sec 30 sec 5 sec 60sec 5 sec 60 sec 10 sec Toggle 10 sec Toggle Tap sensor de Back to MAIN MENU Back to MAIN MENU NOTE Swipe UPWARDS to exit the MENU Example Task Put Relay1 to stay activated 10 seconds Scroll Master Finger 8 times tap scroll 3 times tap swipe UP to exit 11 0 DINB100 SA PROGRAMMING MENU 11 9 Adding Users In Finger On Card Mode when Mifare Reader is connected Swipe the Mas
12. amming Master Admin Fingers Image resolution Backlight ON OFF Buzzer ON OFF Firmware upgrade Current Consumption Power Supply Indication Mounting IP Factor Storage Operating Temperature Storage Operating Humidity Dimensions mm 97 templates 1x Relay 2A 24V AC DC Yes Pulse 1 3 5 10 20 30 60sec or Toggle ON OFF Finger Basic installation Finger or and Card when used with card reader DIN Card reader Finger or and PIN code when used with keypad DINPAD M Finger on Card when used with mifare reader DINMTPX MF By scrolling and tapping on the sensor or by keypad 1 Master and 2 Admin Fingers Up to 508 DPI Yes Yes via RS485 converter and windows application 100 mA max 9 14 V DC Tricolor Status LED and 4 x Programming LEDs DINB100 SA Flush mount IP40 20 C to 50 C 5 to 93 RH without condensation 80 x 80x9 SPECIFICATIONS DINRTT Output Push Button Input Door Time Backlight ON OFF Buzzer ON OFF Power Supply Current Consumption Mounting IP Factor Operating Temperature Dimensions 2 x Relay 2A 24V AC DC 2 Pulse 1 to 60sec or Toggle ON OFF Yes Yes 9 14V DC 60 mA flush mount IP40 indoor use only 20 C to 50 C 80 x 80x9 DINRTT 4 0 APPLICATION DIAGRAM DINRTT Optional 2 Relay Remote Unit and request to exit Button RS485 max 50m II II ra Not
13. and Finger PIN Code or and Finger Finger on Card Complete setup and programming can be done by scrolling and tapping on the sensor or by keypad menu if keypad is connected The sensor incorporates dedicated sensing hardware to facilitate the detection of spoofing attacks based on fake fingers This data is embedded into the image data stream and is processed on the processor The system is capable of detecting and defeating well known fake finger mechanisms such as molded gummy fingers DINRTT is remote relay control unit for the DINB100 SA B100 SA biometric reader If secure installation is needed the biometric reader can be connected to remote relay unit at secured area which also plays the role of exit push button It has two relay output and two exit button inputs 2 0 MOUNTING AND DISMOUNTING 3 0 SPECIFICATIONS SPECIFICATIONS DINB100 SA Do not install the device and cabling close to a source of strong electro magnetic fields like radio transmitting antenna Do not place the device near or above heating equipments If cleaning do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel Do not let children touch the device without supervision Note that if the sensor is cleaned by detergent benzene or thinner the surface will be damaged and the fingerprint can t be entered Fingerprint Capacity Output Push Button Input Door Open Time Entry Mode Progr
14. e 4 frames supplied with the kit o DINB100 SA eo o Standalone Biometric Reader x CO AS ce aso 5 0 WIRING Wiring DINB100 SA Relay Output BR Connection to additional NC card reader or keypad 5 SH NO Electric Door Strike DC powered 12V J Power Supply GND 9 14V DC E Jrsass PB GND Push Button tamp tamp Jumper Adding Master Finger Tamper P Only the Biometric Reader Wiring DINB100 SA DINRTT Remote Relay Unit ol Door1 Door2 12 VDC 1N4007 1N4007 TON WOD TON TON WOD T N DINB100 SA DINRTT 5 O 2 CO Ol Ol Relays O Biometric Reader Remote Relay Unit o O O O O O O O O 000000000 noon TOUT 00000000 N i R RS485 NONA O B A Temp 12V 12V as O GND e RS485 Soy OS x Power Supply 12 VDC Connect the Door Lock on the DINRTT relay The Biometric reader DINB100 SA and the remote Relay Unit max 50m gt DINRTT should be connected with 4 wires A and B RS485 Push Button Inputs Ie Wwwxprgroupcom A 6 0 RECOMMENDED SWIPING TECHNIQUE Follow the below instructions for correct finger swiping Starting from the f
15. irst finger joint place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement A Result gt For a valid swipe Tricolour Status LED turns green OK Beep short long beep For an invalid or misread swipe Tricolour Status LED turns red Error Beep 3 short beeps 6 1 Taping the sensor Tap the sensor to enter Submenu or to confirm a command Enter and confirm 6 2 Scrolling the sensor up and down Scroll the sensor DOWN to navigate the programming menu Navigate the Programming Menu Scroll the sensor UP to exit the programming menu ba Exit the Programming Menu 7 0 INDICATION S OK Beep short long beep Tricolor Status LED 4 x Tricolor Programming LEDs Error Beep 3 short beeps Green Access Granted red green orange Red Access denied Swipe Again 2 short beeps Orange Idle Mode 8 0 QUICK PROGRAMMING 8 1 Adding Master Finger and delete all users DINB100 SA 1 Close the jumper on the back of the device a 2 Reset the Power of the device 3 Wait for One long multiple short beeps 4 0pen the jumper short beeps will stop H 5 Wait for the bottom row LEDs to blink in Orange Blinking gt Ba e lt Blinking 6 Swipe the Master finger min 6 times Until Ok Beep din x6 Note After enrolling the Master finger the device will auto Reset wait for 7 seconds and the OK beep Note This
16. ntil Ok Beep Back to MAIN MENU to Add User menu NOTE Swipe UPWARDS to exit the MENU There is 1 Master Finger The master finger can enroll delete user and all the other settings The Master finger can be changed ONLY with the jumper There are 2 Aministrator Fingers The administrator can do all the things that Master can do The Master can delete the Administrator but the Administrator can not delete the Master 11 0 DINB100 SA PROGRAMMING MENU 11 6 Delete Administrator Swipe the Master Admin finger 13 times until the light pattern on figure 11 is shown Figure 11 Select Admin nr Scroll down to select e Admin 1 M GJ Admin 2 deleting NOTE Back to MAIN MENU Swipe UPWARDS to exit the MENU There is 1 Master Finger The master finger can enroll delete user and all the other settings The Master finger can be changed ONLY with the jumper There are 2 Aministrator Fingers The administrator can do all the things that Master can do The Master can delete the Administrator but the Administrator can not delete the Master 11 0 DINB100 SA PROGRAMMING MENU 11 7 Settings Swipe the Master Admin finger 10 times until the light pattern on figure 7 is shown Figure 7 Remote Relay Touch Function Buzzer Backlight Reset to defaults Continues on the next 2 pages go to next page NOTE Swipe UPWARDS to exit the MENU
17. rolled Please refer to page 6 to enroll Master finger Then set the Entry Mode to Finger or PIN Please refer to page 14 amp 15 to set the reader in Finger or PIN mode In addition to that set the keypad to work with the biometric reader Press B 000000 Press B 000000 Press O Press 4 Press 2 slave mode Press O Any PIN Code length with A in the end PressA PressA Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink ADMIN PIN or x5 L Press 1 Enter user location number 01 to 97 Assign relay Press 1 for Relay1 or 2 for Relay2 Assign user group 1 to 8 Press 1 for group 1 Note The user is automatically i assigned to Relay1 and Press A to confirm group1 ER Enter user PIN code 1 to 8 digits Optional Swipe the User finger min 6 times Until Ok Beep dn x6 To Enroll again go to step 1 To Exit press 0 A Example Task Add a user no 5 with PIN Code 12345 that will activate Relay1 Scroll Master Finger 5 times press 1 press 05 press A press 12345 press A Swipe Finger 6 times press 0 A to exit 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 2 Delete User By User Location Number Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink ER Enter user location number 01 to 97 ER Press A to confirm To Exit press 0 A
18. swipe the finger min 6 times When using Mifare card reader for Finger On Card Mode first swipe the finger min 6 times then present a Card For Fast Deleting a user in Finger On Card mode swipe the Master or Admin finger then present an existing user card 9 0 PAIRING BIOMETRIC READER AND REMOTE RELAY UNIT If secure installation is needed the reader can be connected to remote relay unit at secured area which also plays the role of request to exit push button Follow the instructions bellow to pair couple both devices or refer to the Remote Relay s Manual 9 1 Pairing DINB100 SA with DINRTT Ai DINB100 SA Bag 1 Close the Jumper DINRTT beeps continuously and the red led aa D blinks E SE 2 Open the Jumper 6P 3 Wait for Beep OK Beep short short long beep EIERE f D d E ERS After the OK beep the coupling is done k max 50m i DINB100 SA 1 Put Dipswitch No 1 to position ON RTT beeps continuously and the red led blinks H 2 Put Dipswitch No 1 to position OFF 3 Wait for Beep OK Beep short short long beep 000000000 After the OK beep the coupling is done RS485 F k max 50m i 10 0 KEEP THE DOOR UNLOCKED
19. ter Admin finger 5 times until the light pattern on figure 9 is shown Figure 9 Tap sensor de Select User Group in Swipe the finger to select BL Groupl y Group3 Groupp Group 4 el Group 2 el Group el Group 6 JI Group 8 Tap sensor de Assign Relay Output dm Swipe the finger to select Relay 1 Both BL BL Relay 2 None BL BL 1 NOTE Swipe UPWARDS to exit the MENU m Orange Blinking Swipe the user finger min 6 times Until Ok beep IN x6 The backlight starts to blink green and the buzzer beeps Present the Card and hold it in the proximity field until OK beep which is indication that the finger enrolled is written in the card In Finger on Card mode the fingerprint is stored only into the Mifare card Mifare Classic 1K 4K or DesFire and not in the reader The matching is done by first presenting the card then swiping the finger According to this the system in finger on Card mode does not have capacity limit Furthermore the fingerprint is not stored in the reader s memory which disables any misuse of the stored fingerprint templates Example Task Add a user in Group2 that will activate Relay1 Scroll Master Finger 5 times tap scroll ones tap tap swipe user finger 6 times present the card swipe UP to exit 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 1 Adding Users Important To use the keypad for programming Master Finger must be en
20. tric reader starts to blink 2 Select the Buzzer Code from the Table2 Table2 Buzzer Mode Remote OFF Reader OFF All ON All OFF EJ Press A to confirm To Exit press 0 A Note 1 When Remote OFF is selected the buzzer is OFF in the remote relay unit In the biometric reader and in the keypad the buzzer is ON Note 2 When Reader OFF is selected the buzzer is ON in the remote relay unit In the biometric reader and in the keypad the buzzer is OFF 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 8 Backlight Settings Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink 2 Select the Backlight Code from the Table 3 Table 3 1 Remote OFF 2 Reader OFF All ON All OFF EN Press A to confirm To Exit press 0 A Note 1 When Remote OFF is selected the backlight is OFF in the remote relay unit In the biometric reader and in the keypad the backlight is ON Note 2 When Reader OFF is selected the backlight is ON in the remote relay unit In the biometric reader and in the keypad the backlight is OFF 12 0 PROGRAMING DINB100 SA WITH KEYPAD 12 9 Set the Touch Button Function Swipe Master Admin finger or enter Admin PIN The Biometric reader starts to blink 2 Select the Touch Code from the Table 4 Table 4 Touch Mode Touch ON Touch OFF 3 Press A to confirm
Download Pdf Manuals
Related Search
Related Contents
User`s manual - World Health Organization Hotpoint HDA6009 Dishwasher User Manual Edimax BR-6478AC router Samsung 206BW Felhasználói kézikönyv User`s Guide Hygro-Thermometer + InfraRed Thermometer Model Denon AVR-1311 DVD Player User Manual Huawei AR1220 Ethernet LAN Silver Copyright © All rights reserved.