1. functions have to be checked ore Service ay 761 9331 BuyControls us Specification Pe oe without notice an ee peeees 9730 Distribution Avenue San Diego CA 92121 rinted in Germany User Manual GA T70 024 Page 9 l g BuyC ntrols us Controls Peripherals Easy shopping 8 Dimensions 2 72 R 69 00 disengage button Ke N F a x a inches mm 4 53 gt Anti rotation mounting bracket supplied w actuator 115 00 9 Ordering information GA T70 024 w Plenum rated cable GA T70 024 S1 w Plenum rated cable and 1 aux switch GA T70 024 P1 w Plenum rated cable and 1 1 kQ Pot GA T70 024T w Terminal block GA T70 024T P1 w Terminal block and 1 1 kQ Pot Note Terminal version actuator comes without L R selector and adj visual position indicator Fax 858 578 4633 9730 Distribution Avenue San Diego CA 92121 Printed in Germany Customer Service 858 761 9331 BuyControls us Specification subject to change without notice User Manual GA T70 024 10 Specifications Control Input signal Electrical Power supply Over voltage Power consumption Performance Torque Damper size Angle of rotation CCW L and CW R Rotation time Power failure Position indicator Synchronization Overload protection Manual override Motor type Noise level Environmental Permissible ambient working temperat
2. rotation is adjusted operating position S1 S3 Fax 858 578 4633 Customer Service 858 761 9331 BuyControls us 9730 Distribution Avenue San Diego CA 92121 Specification subject to change without notice Printed in Germany User Manual GA T70 024 Page 7 g BuyC ntrols us ES s Controls Peripherals Easy shopping 6 Wiring configuration Notes e Actuators are provided with color coded wires Wires for optional switches and feedback pot are number coded e Observe polarity on secondary of transformers Incorrect polarity can cause controller damage or operation error e Provide overload protection for line voltage and disconnect as required GA T70 024 Tri state 3 point floating control Option S1 Line L2 Volts L1 1 Auxiliary switch SPDT 24 VAC 5 2 5 A w adjustable cam for any position setting 24 VAC Transformer GA T70 024 On Off control Option P1 Eneka 1 Feedback pot 1 KQ Volts L1 0 Q at 0 angle of rotation 24 VAC Transformer 4 Terminal version wiring connection L R selector built in actuator cover 1 com 2 CW 0 90 3 CCW 90 0 Select Angle of rotation R CW 0 90 w red connect R CCW 90 0 w white connect L CW 0 90 w white connect Multiple actuators GA T70 024 L CCW 90 0 w red connect maximum quantities Tri state or On Off Stacking torque is additive 4 Parallel connectio
3. endee cegteustieseceseeennececaetescesectecen eveveustiteaecetaedencducteteestenes 10 esa Service aay 761 9331 BuyControls us Specification act ee without notice aX 899 5 6546093 9730 Distribution Avenue San Diego CA 92121 rinted in Germany User Manual GA T70 024 Page 4 l ply iBuyCOntrols us Controls Peripherals Easy shopping Direct coupled non spring return actuators 70 in lb 1 Application Actuators to be easily installed by direct shaft mounting on air dampers shutters and butterfly valves in ventilation and air conditioning systems Can be controlled by any compatible electric or electronic analog controller DDC PLC control or automation system The actuators should be mounted indoors in a dry envi ronment relatively free from corrosive fumes 2 Safety remarks The actuators are not suitable for use in explosive atmospheric applications All service to the actuators mounting electrical connection retrofitting and repair must be carried out with the power supply disconnected The electrical connection must be done by a trained and competent person consi dering the wiring diagrams local and national regulations Use copper twisted conductors only Provide dis connect and overload protection if necessary This actuator may only be operated by 24 VAC VDC The transformer must be sized according to technical data of the actuator see section 10 Always read the controller installation instructions befo
4. ls Peripherals Easy shopping 3 ft 0 9 m cable color coded plenum rated 18 AWG 0 75 mm Terminal block outside of cover screw type for lead wire min 26 AWG 0 14 mm max 14 AWG 2 5 mm 4 53 x 2 56 x 2 40 in 115 x 65 x 61 mm 1 2 Ibs 0 53 kg ISO 9001 certified CE UL and CSA Five year material and workmanship Two year standard three year conditional SPDT 24 VAC 5 2 5 A adj at any position incl 3 ft 0 9 m cable number coded plenum rated or terminal block 1 KQ pot incl 3 ft 0 9 m cable number coded plenum rated or terminal block Specification subject to change without notice Printed in Germany
5. n 20 Fax 858 578 4633 9730 Distribution Avenue San Diego CA 92121 Printed in Germany Customer Service 858 761 9331 BuyControls us Specification subject to change without notice Controls Peripherals Easy shopping User Manual GA T70 024 Page 8 g BuyC ntrols us 7 Parallel control of two or more actuators Notes e Provide overload protection and disconnect as required Actuator and controller must have separate transformers e Set reversing switch L R as required GA T70 024 Tri state 3 point floating control Line L2 Volts L1 24 VAC Transformer Attention e Observe polarity on secondary of transformers e Connect all actuator blk wires 1 to line of transformer and all red 2 and wht 3 wires of parallel controlled actuators together via switch to the other leg of the transformer Before starting the operation all electrical and mechanical functions have to be checked GA T70 024 On Off control 1 i 2 ia com com l an l x blk red wht blk red wht gt Line L2 Volts L1 24 VAC Transformer Attention e Observe polarity on secondary of transformers e Connect all actuator blk 1 wires to line of transformer and all red 2 wire to the other leg of the transformer e White 3 lines of parallel controlled actuators are connected together via switch to the volts line Before starting the operation all electrical and mechanical
6. pmeycontoss ERNE Controls Peripherals Easy shopping GA T70 024 Direct coupled non spring return actuators 70 in Ib User Manual July 2003 CE LISTED ISO 9001 ore cen a BuyControls us Specification subject to change without notice ax 858 578 9730 Distribution Avenue San Diego CA 92121 Printediin Germany User Manual GA T70 024 Page 3 g IBuyCOntrols us Controls Peripherals Easy shopping page 1 Application as as ieseana a akanai aeaaaee aae aeara E Aaa area ee aeara aatan aaea 4 2 Safety rema TKS concede aaaea diac a ra ae araea a Ea tucecaudecncwcs vat dcceeedvasiusetes dadin Enor eranan tnn 4 3 Installation cccicceccsesettecetevedsdeue eee satarsa anaoa bade a raaa naroa tetaneceatadeeneleatadeeeeeseeliverarvenees 4 4 Adjustment of the angle of rotation 2 c cccceeeeeeeeeeeeeeeeeeeeeeceee seen eens canes seeeeseeeeeneneens 5 5 Adjustment of the rotation direction and of the auxiliary Switch cceeeeeeeee 5 6 Wiring configuration n nisa araa sete aa ta teed eaa aa aaea Eaa Ea santana aada naa dics 7 7 Parallel control of two or more actuators ssssssssssesunuunnnnrnnnnnnnnnnnnnnnununnnnnnnnnunnnn mnnn nenen na 8 B DIMENSIONS e EE A E A E E 9 9 Ordering informatio M ar araa aaant ra debated ated de seceudicecwen vac daceyetvesseseted cist ddvetenh aneneties 9 10 Specification ccccccecccccsesceeececeteesesecs
7. re making any connection 3 Installation Direct mounting with V bolt clamp to the damper shaft diagr 1 and fixing with enclosed anti rotation mounting bracket diagr 2 Shaft 5 46 to 5 8 8 16 mm O 5 46 to 15 39 O 8 12 mm Turn the damper until the blades are closed e Disengage the gears by pressing the red button and rotate the clamp until the switching position indication shows 90 e Tighten the nuts on the clamp 4 6 ft lb diagram 1 diagram 2 fare 800 0 91693 9730 Distribution Avenue San Diego CA 92121 Printed in Germany Customer Service 858 761 9331 BuyControls us Specification subject to change without notice User Manual GA T70 024 4 Adjustment of the angle of rotation Both end stops are adjusted to 0 and 90 For smal ler rotation angles loosen the screws 1 at the metal end stop adjust the end stops as required and fasten the screws again 5 Adjustment of the rotation direction and of the auxiliary switch Rotation direction The actuator is adjusted to clockwise direction by the factory gt R To change the direction of rotation turn the adjustment knob 2 to L Types with terminals have no knob In this case chan ge and Auxiliary switch The scale at the adjustment knob 3 corresponds to a percentage graduation related to 0 to 90 Drive is placed at 0 on the end stop Turn the adjustment knob from 0 to
8. the right until the tip indicates the required switching position For example 2 20 of the angle of rotation Drive turns to the right and the switch switches at 20 of the angle of rotation operating position S1 S3 Drive at operating position Press the override button and turn the drive to the required operating position for example 20 of the angle of rotation Turn the adjustment knob to 0 and pass with the tip slightly As a result 20 of the angle of rotation is adjusted operating position S1 S3 IBuyCOntrols us Controls Peripherals Easy shopping Fax 858 578 4633 Specification subject to change without notice 9730 Distribution Avenue San Diego CA 92121 Customer Service 858 761 9331 BuyControls us User Manual GA T70 024 Page 6 g IBuyCOntrols us Controls Peripherals Easy shopping a Drive is placed at 1 on the end stop Turn the adjustment knob from 1 to the left until the tip indicates the required switching position For example 8 20 of the angle of rotation Drive turns to the left and the switch switches at 20 of the angle of rotation operating position S1 S3 Drive at operating position Press the override button and turn the drive in the required operating position for example 20 of the angle of rotation Turn the adjustment knob to 1 and pass with the tip slightly As a result 20 of the angle of
9. ure storage temperature humidity Physical Enclosure cover base color protection Mounting position Anti rotation bracket Stacking paralleling Clamp connection to round shaft square shaft Customer Service 858 761 9331 Fax 858 578 4633 Tri state 3 pt floating or On Off 24 VAC DC 24 VAC VDC 20 50 60 Hz Up to 40 V max 5 sec 2 0 W 3 0 VA 70 in lb 8 Nm Up to 18 sq ft 1 6 m 0 95 95 0 selectable adj angle with integral stops L R selector built in actuator cover Terminal version is w o L R selector 60 to 120 sec 0 90 Stays in last position of operation 0 10 divisions and adj visual indicator Terminal version is w o visual indicator 1 Electronic throughout rotation Built in disengage button DC motor Max 35 dB A 22 F to 122 F 30 C to 50 C 40 F to 176 F 40 C to 80 C 5 95 RH non condensing ABS UL 94 5V PA 6 6 Gray and black NEMA 2 NEMA 1 for Terminal version Any position Included w actuator Refer to table Multiple Actuators 5 46 to 5 g 8 to 16 mm O 5 46 to 15 32 8 to 12 mm Page 10 ph IBuyControls us Wire connection Wire size Terminal version wire connection Dimensions Weight Manufacturing Listings Approvals Warranty Options S1 1 Aux switch built in P1 1 Feedback pot BuyControls us 9730 Distribution Avenue San Diego CA 92121 Contro