1.   Altus S  A     PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908     B    Setup  Redundant PROFIBUS DP Network     The redundant PROFIBUS DP network configuration allows to maintain the redundant system operating even occurring a  failure in a redundant slave s head  interruption in data transmission or line failure in one of the Master Interfaces  This type  of configuration consists of a CPU connected to two PROFIBUS DP Master Interfaces  NX5001   These interfaces make  up networks A and B  each with their heads NX5210  In the example below the bus consists of a CPU NX3030 and two  Nexto PROFIBUS DP NX5001 Masters     NXS00T  NAST    a A  uf Wi  A A  m e    NAS52 10  NASZ 10       Altus S  A  8    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908     C    Setup  Redundant PROFIBUS DP Network     Allows to maintain the operation of the system even in a failure in of a redundant slave s head  a disruption of data  transmission lines  in one of the Interfaces or in one of the masters  This type of configuration consists of two Master s  PLCs  each connected to two Master PROFIBUS DP Interfaces  In the example presented each CPU is composed of a  NX3030 and two Nexto PROFIBUS DP NX5001 Masters     NX3030  NX4010       y  A  Z    NX3030       NXSZI1IO  NAS2Z10    Network A  Network B      5  uf  TE  Sl  E  Z Z       Altus S  A  9    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    Software Features    The Ne
2.   Expansion I O modules without the need to disable the network  hot expansion   Ethernet interface for firmware update   Local advanced diagnostic service   Diagnoses and States of local operation via LEDs  and display in the Panel  One Touch Diag   Free of moving parts  fans  coolers  etc         Ordering Information    Included Items  The product package contains the following items        NX5110 or NX5210 module  e 6 Terminals Connector     Installation Guide    Product Code    The following codes should be used to purchase the product      NX5110  PROFIBUS DP Head     NX5210   PROFIBUS DP Redundant Head       Altus S  A  1    PROFIBUS DP Heads NX5110  NX3210    Nexto Series    Doc Code   CE114908    Related Products    The following codes should be used to purchase the product     CPU with 1 Ethernet port  1 serial channel  support for expansion bus and  NX3004  integrated power supply  High speed CPU  1 Ethernet port  2 serial channels  memory card  NX3010   i  interface and support for bus expansion  High speed CPU  2 Ethernet ports  2 serial channels  memory card  NX3020   l  interface and support for bus expansion  NX3030 High speed CPU  2 Ethernet ports  2 serial channels  memory card  interface  support the expansion bus and support for redundancy  AL 2601 PROFIBUS DP Derivador Connector  AL 2602 PROFIBUS DP Termination Connector  AL 2605 Terminator With Supply Diagnostic  AL 2303 PROFIBUS Network Cable A Type  AL 2431 Optical Repeater FOCOS PROFIBUS  AL 2432 Optic
3.   MU214305 Manual del Usuario UCPs Serie Nexto Spanish    MU299609 MasterTool IEC XE User Manual English  MU299048 Manual de Utiliza    o MasterTool IEC XE Portuguese  MU299800 Manual del Usuario MasterTool IEC XE Spanish    MU299026 Manual de Utilizac  o da Rede PROFIBUS Portuguese    z         Manual de Utilizac  o do Repetidor Otico   FOCUS    PROFIBUS Portuguese       Adherence to PROFIBUS DP Redundancy Standard  The Altus Redundancy System is based on PROFIBUS DP Slave Redundancy Standard  reference below   The Altus  Redundancy system respects the most significant items of the standard cited below   2 PROFIBUS DP connections  2 interfaces communicating PROFIBUS DP independents  1 redundancy channel for communication  A single redundant system implementation for all types of network topology  Fast system recovery from failure occurrence    The points of the standard that are not met are the following     e The addresses of the slaves are determined using rotating switches  There is no differentiation between Primary and  Standby slave addresses  e No acyclic communication between the Master and its slaves  with the exception of diagnostic communication    For more information about the PROFIBUS DP Redundancy Standard  see Guideline Order No  2 212   Specification Slave  Redundancy  Version 1 0  January 2000     Altus S  A  15    
4.  connector for PROFIBUS DP fieldbus network without internal termination  It can be used to connect any  PROFIBUS DP equipment in a position in which the termination is not required    e AL 2602 is a connector for PROFIBUS DP fieldbus network with internal termination  It should be used on  PROFIBUS DP equipment located at the ends of the fieldbus network  Altus also offers a second option for  requirements where reliability and availability are key requirements  For these cases a connector AL 2605 should be  used at each end of the field network and all modules PROFIBUS DP without internal termination connectors should  be used with AL 2601  More information about the AL 2605 module can be found in document CE104705    The use of two network PROFIBUS DP terminations is obligatory  Each termination should be positioned at each end of  the network fieldbus     5  The grounding from the external power source is connected to the terminal  amp   Use 0 5 mm  cables  6  The power supply is connected to terminal 0 v  Use 0 5 mm 2 cables   7  The power supply is connected to terminal 24 v  Use 0 5 mm   cables   8  The power supply feeds the internal circuit directly   9  Local data bus   10  The module feeds the other modules of the Nexto Series through rack connection   11  The grounding of the module is done via the Nexto Series rack    Altus S  A  12    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    Mechanical Assembly    The mechanical Assembly for thi
5. FIBUS DP heads NX5110 and NX5210 of Nexto Series have two LEDs  and an LED to indicate diagnoses  LED DG    another LED to indicate the occurrence of watchdog  WD LED   More information about diagnostic LEDs can be found in  Status and diagnostic Indicators section        Graphical Display    PROFIBUS DP heads NX5110 and NX5210 of Nexto Series have a graphical display used to show the status and  diagnosis of the entire system  including the additional module specific Diagnostics  More information about how to use the  graphical display can be found in the user Manual of the PROFIBUS DP Head Nexto MU214608     VO Capacity    NX5110  A remote PROFIBUS DP  with the NX5110 module  has its limited capacity by the following values     e total number of modules in the same backplane rack  22  e maximum number of bytes to be transmitted over the network  240 input bytes and 240 output bytes    NX5210  A remote PROFIBUS DP  with the NX5210 module  has its limited capacity by the following values     e total number of modules in the same backplane rack  20  e maximum number of bytes to be transmitted over the network  238 input bytes   2 redundancy control bytes and 238  output bytes   2 redundancy control bytes    O Modules    The maximum number of points depends on the type of points used  For example  the threshold for digital is 640 points  20  modules   But for analog the limit points are 96 points  12 modules   The maximum number of a mixed configuration is  limited by the maxim
6. Normal Operation 3  Lower        Blinking 1x Software Watchdog Watchdog generated by software  On O  Hardware Watchdog Damaged Module 1  Higher     Notes     Software Watchdog  To remove the indication of watchdog  it   s necessary to unplug and reconnect the module  This  watchdog occurs when the runtime of the internal software is longer than one second  If this error manifests itself with  frequency  contact should be carried out with the technical support of Altus     Hardware Watchdog  To clear any indication of watchdog  as the WD LED or tDetailed Reset bWatchdogReset operand   it is necessary to disconnect and reconnect the module     Graphical Display    The NX5110 and NX5210 Nexto Series modules have a graphical display used to show the status and diagnostic system     including the additional module specific Diagnostics  More information about how to use the graphical display can be found  in the User Manual of Nexto PROFIBUS DP Head MU214608     Diagnostics via Variables    Altus S  A     All diagnoses of the modules NX5110 and NX5210 can be accessed through variables that can be manipulated by the user  or application even forwarded to a supervisory using a communication channel  There are two different ways to access the  user application Diagnostics  using the AT in symbolic variables or variables of direct representation  Altus recommends    the use of symbolic variables  More information on how to access the Diagnostics through variables can be found in your  
7. PROFIBUS DP Heads NX5110  NX5210    Nexto Series  A     Doc Code   CE114908    Product Description    The Nexto Series is a powerful and complete series of Programmable Controllers  CP  with unique and innovative features   Due to its flexibility  intelligent design  advanced diagnostic capabilities and modular architecture  Nexto series can be used  to control systems in medium and large applications  Due to its compact size  high density of points for modules and  superior processing capability  the Nexto can also be applied in smaller automation systems with high performance  requirements  such as manufacturing and industrial applications    The Nexto Series presents a wide variety of modules for communication with networks with features to suit different types  of application  The NX5110 and NX5210 modules are devices of type head slave for PROFIBUS DP networks  allowing the  user to use all modules I O Series Nexto     Its main features are     e PROFIBUS DP Protocol for communication of I O data   e High communication speed  baud rate up to 12 Mbits s    e Compatible with any PROFIBUS DP master equipment  following the standard EN  50170   PROFIBUS DP network addressing in the front   Ability to use up to 22 I O modules in a single rack   Redundancy support  using two heads NX5210    Support hot swap  only NX5210    Support hot swap I O modules   Auto parameterization and configuration of the I O modules via PROFIBUS DP  master  class 1    Automatic baud rate detection 
8. User Manual for the PROFIBUS DP Head Nexto MU214608     14    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    Manuals  For the correct application and use see the User Manual of Nexto PROFIBUS DP Head MU214608     For further technical details  configuration  installation and programming of the Nexto Series the table below should be  consulted    The table below is just a guide of some relevant documents that may be useful during use  maintenance and programming  of Nexto Series PROFIBUS DP heads  The complete and updated table containing all the documents in the Nexto Series  can be found in the Nexto Series User Manual MU214600     Code    CE114000 Nexto Series     Technical Characteristics English  CT114000 S  rie Nexto     Caracteristicas T  cnicas Portuguese  CS114000 Serie Nexto     Especificaciones y Configuraciones Spanish  MU214600 Nexto Series User Manual English  MU214000 Manual de Utilizac  o S  rie Nexto Portuguese  MU214300 Manual Del Usuario Nexto Spanish  MU214608 Nexto PROFIBUS DP Head Utilization Manual English    MU214108 Manual de Util  Cabe  a PROFIBUS DP Nexto Portuguese  MU214308 Manual de Util  Cabega PROFIBUS DP Nexto Spanish    MU214601 NX5001 PROFIBUS DP Master User Manual English    MU214001 Manual de Utilizac  o Mestre PROFIBUS DP NX5001 Portuguese  MU214301 Manual del Usuario Maestro PROFIBUS DP NX5001 Spanish    MU214605 Nexto Series CPUs User Manual English  MU214100 Manual de Utiliza    o UCPs S  rie Nexto Portuguese
9. al Repeater FOCOS PROFIBUS with Two Optical Ports  AL 2433 PROFISwitch     Coupler for Redundant Profibus Network  NX5001 PROFIBUS DP Master Interface  PO4053 PROFIBUS DP Master Interface    AL3406 PROFIBUS DP Master Interface  MT8500 MasterTool IEC XE    Notes     AL 2601  the derivador connector for PROFIBUS DP network is a connector type DB9 with standardized pinout according  to EN 50170 and without termination  It is suitable for connection to PROFIBUS DP devices mounted on intermediate  positions in the PROFIBUS DP network  i e  physically not mounted at the ends of the network  This connector has input  and output connection of the cable network  enabling disconnection be done without disrupting the continuity of the  physical network    AL 2602  PROFIBUS DP terminator connector is a connector type DB9 with standardized pinout according to EN 50170  and termination  It is suitable for connection to PROFIBUS DP devices mounted on the ends of the physical network   beginning and end     AL 2605  the terminator with diagnosis of font is used in the extremes of redundant networks  where is needed to make the  exchange of devices without losing the endings    AL 2303  cable for data communication on PROFIBUS DP network    AL 2431 e AL 2432  optical repeaters for interconnection between any PROFIBUS DP equipment through optical fiber   The module AL 2432 has redundancy of optical transmission by adding increased availability to the system    NX5001  PROFIBUS DP Master     Ne
10. enabled  has  11 bytes of output    Baud rate  The baud rate is detected in the following communication speeds  9 6 kbits s  19 2 Kbit s  93 75 Kbit s  187 5  Kbit s  500 Kbit s  1500  3000 Kbit s Kbit s Kbit s 6000 and 12000 Kbit s     Network redundancy support  his implementation is described in the System Settings section     Isolation  In order to identify the different circuits and component sets that have isolation on the product  the term logic is  the name given the internal interfaces as memories  and interfaces with the rack     Max Current Provided to the Bus  The modules NX5110 and NX5210 have an integrated power supply that can provide  to the bus 3 A of current to power the I O modules     Conformal Coating  The coating of electronic circuitry protects the internal parts of the product against humidity  dust and  other harsh elements to electronic circuits        Altus S  A  4    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    ATTENTION     The modules NX5110 and NX5210 do not have network terminators  requiring the use of  external termination modules        Power Supply             92     24 Vdo    Maximum input voltage    Isolation    Input to Output 1000 Vac   1 minute    Input to Earth Protection   1500 Vac   1 minute  Input to Functional Earth A 1500 Vac   1 minute      Reverse polarity protection  Yes    Internal Resettable fuse  Yess  Short circuit protection on the  output    Over Current Protection    Diagnostics LEDs    PRO
11. h   density of I O points along with complex modules  such as CPUs  fieldbus masters and power supply modules     IF Product Design Award 2012  Nexto Series was the winner of iF Product Design Award 2012  in industry   skilled trades group  This award is recognized internationally as a seal of quality and  excellence  considered the Oscars of the design in Europe     product  design award       Product Features    Specific General Features         NX5110 NX5210  PROFIBUS DP Fieldbus    Module Type PROFIBUS DP Fieldbus Head Redundant Head    Communication Protocol PROFIBUS DP  standard EN 50170             Sync Freeze Support  Backplane Rack Occupation 2 Sequential Positions        n    Maximum Number of Modules 22    238 data bytes   2 bytes  regarding the head status    238 data bytes   2 bytes of  User Commands    Input Capacity 240 input bytes  Output Capacity 240 data bytes    Automatic Baud rate detection from 9 6 to 12 000 Kbit s  10 100 Mbps   Display  web page and LEDs   No Yes   No Yes        O       I O Hot Swap Support Yes  One Touch Diag  OTD     Electronic Tag on Display  ETD         PROFIBUS GUIDE LINE  ORDER no  2 212   Attended Standards PROFIBUS SPECIFICATION    SLAVE REDUNDANCY  version 1 0    Altus S  A  3    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908      PROFIBUS European Norm EN 50170    IEC 61131 2 2003  chapters 8 and 11    CE directives for electromagnetic compatibility  EMC  and low  voltage    E  ROHS  2002 95 EC  See ge
12. iagnostic button  After pressing the Head will show the module Diagnostics     More information on One Touch Diag can be found in the user Manual Series Nexto MU214600     Status and diagnostic Indicators    The modules NX5110 and NX5210 have graphical display containing status and information of interest to the user  such  as  operating mode of the interface with network redundancy enabled  IP address of the Ethernet interface  Sync mode   indication and or Freeze  Additionally  it also provides Diagnostics related to interface and PROFIBUS DP network LED  DG  A second LED is used to indicate the occurrence of watchdog  WD LED      DG  Diagnostic      Green  Red   Description JO ses   Priory    Cyclical data are exchanged with Communication with PROFIBUS DP  y 5  Lowe   master master was established  ey at Some bus module  including the head  oe   i l PROFIBUS DP master has not yet sent  IS om Vinou conNgUTaton the parameterization and configuration  Blinking 1x Configuration or Hardware error on Configuration   Parametrization Error o  bus Check diagnosis structure       iso   PROFIBUS DP network cable faulty  No di Meee   Network cable not connected 1    PROFIBUS DP termination error    Fatal hardware Problem  Head s hardware error   Error in memory of PROFIBUS DP O  Higher   coprocessor    Altus S  A  13    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    WD  WatchDog       Green   Red   Description   Causes    Off   Off   No Watchdog indication 
13. neral features of the series     ALT _ OEDD GSD ALT OEDE GSD  Isolation    PROFIBUS Interface to Logic 1000 Vac   1 minute    PROFIBUS Interface to Earth Protection     Pres dle    Logic to Earth Protection S 1250 Vac   1 minute    5 a 96    non condensing    Conformal Coating Yes    A O  MA ss    Notes     Maximum Number of Modules  The maximum number of modules is related to greater backplane rack available in Series  Nexto  with 24 positions  two positions are occupied by the NX5110 module  allowing the use of a maximum of 22 modules  in this frame  There are still other limits that are to be taken into consideration  such as the consumption of each I O module  and also the number of bytes of input and output that each module has  In this way  this limit may be reduced in the light of  these other requirements   Input Capacity  Each PROFIBUS DP remote s ability to convey the master module the limit of 240 bytes of input  thus it is  necessary to consult the user Manual of the Nexto PROFIBUS DP Head MU214608 the number of bytes of each module  entry consumes  For example  the HSC NX1001 module  module NX1001 counter mode enabled  has 16 bytes of input   Output Capacity  Each PROFIBUS DP remote has the ability to receive the master module the limit of 240 bytes of  output  thus it is necessary to consult the user Manual of the Nexto PROFIBUS DP Head  MU214608 the number of bytes  of each module output consumes  For example  the HSC NX1001 module  module NX1001 counter modes 
14. s module is described in the user Manual Series Nexto MU214600  There is no special  point about the installation of this module     Parametrization    The parameterization of the head and the connected modules is made by the PROFIBUS DP master  The parameters of  the head are transmitted via the PROFIBUS DP network  without the need for additional configuration     The parameters of the head are described in its Manual   The parameterization of the modules is described in the CEs     GSD File    All head s configurable options and the modules are defined in a file named PROFIBUS DP GSD standard  This file follows  the programmer MasterTool IEC XE     To use the head with other master manufacturers the file can be obtained at www altus com br or with the support of Altus     Maintenance    Altus recommends that all modules    connections be checked and that all dust or any kind of dirt located at the module   s  enclosure be removed at least every 6 months     The NX5110 and NX5210 modules offer four important features to assist the user during maintenance  One Touch Diag   Diagnostics and Status Indicators and Diagnostics mapped in internal memory     One Touch Diag    One Touch Diag is an important feature that allows the user the option to verify the diagnoses related to a given module  directly in the graphical display of the head     One Touch Diag is an easy to use functionality  To verify the diagnosis of a given module just a short press  less than 1  second  on the d
15. security state that sustains the parameterizable time outputs if the redundancy system has no communication  with the Master   e Allows hot swap of any of the NX5210 heads without affecting the application  This operation is possible provided that  the two heads are in Active or Standby status  respectively   e Through master s commands it is possible to request the return of Active standby state  switchover  to redundant  system    Altus S  A  10    PROFIBUS DP Heads NX5110  NX5210    Nexto Series       Doc Code   CE114908    Physical Dimensions    Dimensions in mm     NANA         NU MMM Le i ee i         127 79     fA Ahh ed 41414114    NAC       XI     o  N  O  LO  O          Altus S  A  11    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    Installation  Electrical Assembly  The installation in rack  rack backplane  can be seen in the figure below   NX5110  NX5210       D  or  Q  O        G    Bus  A   C   C K   P   L   A   N   E   R   A   C   K     gt   58  OF  O  QO  o  a     14042501A    Diagram Notes     1  2  The address of the PROFIBUS DP Slave is set by key x 1 and x 10 so that the unit is set in the key x 1 and the dozen  is set in the key x 10  As an example  the rack with address 15 must have 5 in x 1 and 1 in x 10    3  Standard Ethernet interface 10 100Base TX to access the Diagnostics and Firmware update through Web page   4  Use the cable AL 2303 for PROFIBUS DP fieldbus network and one of the following connectors    e AL 2601 is a
16. tem consists basically of two fieldbus network heads NX5210 connected via backplane rack of Nexto  Series I O modules  These heads are each connected in a Master PROFIBUS DP interface  One of these heads  called  Active is responsible for reading and writing in input and output modules  The other head  called Standby  has the function  of monitoring  When the Active Head  presents some problem  the Standby head takes over the control of Nexto Series  backplane rack  without any damage to the application being executed    The redundancy system has the following features  according to PROFIBUS DP Redundancy Standard      e  NX5210 modules can be connected individually on PROFIBUS DP networks  In this case  the modules must have the  same network address   e The redundancy system can be implemented by masters who do not possess the characteristics of redundancy  For  this it is necessary that the application on CPU to implement redundancy algorithm described in the Nexto Head  PROFIBUS DP User Manual   e The redundancy system can be implemented with a master that suits the way of implementation of the NX5210  module  NX5001 PROFIBUS DP Master for example    e Redundancy informations are controlled by a virtual module and accessed by master in the same way as an ordinary  I O module   e The Standby Head is identified in the display   e An expansion can be made of nodes modules without disabling the PROFIBUS DP network  Hot expansibility   through the redundancy system   e Owns a 
17. um number of total bytes  depending on the model of the PROFIBUS DP head used  The density  in  bytes  of the I O modules can be seen below     Altus S  A  5    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    16 points digital modules  2 bytes   Digital module NX1001 in HSC mode  16 input bytes and 11 output bytes  Digital Module NX1005 in HSC mode  15 input bytes and 12 output bytes  8 points Analog Modules  16 bytes    For further details see the User Manual of Nexto PROFIBUS DP Head  MU214608     Integrated Power Supply Capacity    NX5110 and NX5220 heads have integrated power supply with a maximum current capacity of 3 amps  This feature allows  feed I O modules without the need for additional modules on bus  However  you should consult the consumption of each  I O module in their respective technical specifications  CEs  to the proper system configuration     In the redundant head NX5210  the fact of existing source redundancy does not increase the ability of bus modules     Altus S  A  6    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    System Settings     A    Setup  Single PROFIBUS DP Network     The PROFIBUS DP network configuration allows simple connection between a master and slave devices through a single  network  The following figure illustrates this connection by using Nexto Series PROFIBUS DP Master NX5001  however     this same link can be applied with other PROFIBUS DP master     F    4 pe  zZ Z         
18. xto Series  PO4053  PROFIBUS DP Master     Ponto Series  AL3406  PROFIBUS DP Master     AL Series    MT8500  MasterTool IEC XE is available in four different versions  LITE  BASIC  PROFESSIONAL and ADVANCED  For  more information  please consult the user Manual of the MasterTool IEC XE MU299609       Altus S  A  2    PROFIBUS DP Heads NX5110  NX5210    Nexto Series    Doc Code   CE114908    Innovative Features    The Nexto Series brings users various innovations in use  Supervision and maintenance of the system  These features  were developed focusing on a new concept in industrial automation  The list below shows some of the features that the  user will find NX5110 and NX5210 modules     One Touch Diag  One Touch Diag is an exclusive feature that Nexto Series brings to PLCs  With  this new concept  user can check diagnostic information of any module present in the system  directly on CPU   s graphic display with one single press in the diagnostic switch of the respective  module  OTD is a powerful diagnostic tool that can be used offline  without supervisor or  programmer   reducing maintenance and commissioning times           DHW   Double Hardware Width  Nexto Series modules were designed to save space in user cabinets or machines  For  this reason  Nexto Series delivers two different module widths  Double Width  two backplane rack slots are required  and  Single Width  only one backplane rack slot is required   This concept allows the use of compact I O modules with a hig
19. xto Series brings to the user the MasterTool IEC XE  a powerful tool that provides a complete interface for  programming of all modules of Nexto Series  This means that there is no need for other software to perform the  configuration of the PROFIBUS DP Slave  All configurations are done in the same software used for programming the  Nexto Series CPUs     Another important point is that all the parameterization of PROFIBUS DP Slave is sent to the NX5001 module through the  Nexto Series CPU  not needing special cables to the module s configuration     Compatibility with Other Products    NX5110    The following table provides information concerning the compatibility between the NX5110 module with the programming  tool IEC MasterTool XE and other Nexto Series Modules     Software Version Software Version  NX5001  cornet  MT8500            NX5210    The following table provides information concerning the compatibility between the NX5210 module with the programming  tool IEC MasterTool XE and other Nexto Series Modules     Software Version Software Version  NX5001 1 2 0 0 or above  MT8500               Redundancy Capacity    NX5210 head has the ability to be linked to other NX5210  share the same I O modules  forming a redundant System  which provides greater reliability to the fieldbus network  The redundant system implemented is the Altus redundancy  System  based on the European standard of PROFIBUS DP Redundancy     Altus Redundancy System Implementation    The redundancy sys
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Thickness Gauge  GUIA DO USUÁRIO - Support  Manuel Utilisateur Game Maker V6.1 (FR)    User Manual Cable TV RF Measurements Software for Windows    Page 1 Page 2 ー安全のため必ずお守りくださ い りここに示した注意  Emerson NetReach CoolPed 3.0 Installation Manual  Scientific Atlanta 940 DVR User Manual    Copyright © All rights reserved. 